2
Remedy Publications LLC., | http://clinicsinsurgery.com/ Clinics in Surgery 2017 | Volume 2 | Article 1651 1 Using the Vessel Ligature Clip to Make the Mismatched Hepatic Artery Microsurgical Anastomosis Easier and Effective OPEN ACCESS *Correspondence: Levent Yalçin, Departemnt of Orthopaedics and Traumatology, Selcuk University, Konya, Sakayik sokak No: 58/1 Nisantasi, İstanbul, Turkey, Tel: 905322134589; E-mail: [email protected] Received Date: 10 Jul 2016 Accepted Date: 25 Sep 2017 Published Date: 05 Oct 2017 Citation: Yalçin L. Using the Vessel Ligature Clip to Make the Mismatched Hepatic Artery Microsurgical Anastomosis Easier and Effective. Clin Surg. 2017; 2: 1651. Copyright © 2017 Levent Yalçin. Ghanem. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Clinical Image Published: 05 Oct, 2017 Levent Yalçin* Departemnt of Orthopaedics and Traumatology, Selcuk University, Konya, Turkey Clinical Image ere are some specific challenges in microsurgical anastomosis of mismatched Hepatic Arteries in Living Donor Liver Transplantation. Hepatic Artery anastomosis is an important part of the Liver Transplantation from living donor [1,2]. Mismatching of arterial diameter is not unusual. Most of the arteries could be anastomosed end to end aſter stretching the artery which has a narrow diameter. Also sometimes doing a very shallow fish mouth incision on the artery which has narrow diameter is very helpful for anastomosing with the other artery. But if mismatching between arterial diameters are more than 30% to 50% these techniques are not enough. Cone-shaping is a well- known technique to make narrow the wide diameter artery to adopt the other one. Classic technique is performed by cutting and suturing the end wall of the artery by creating a semi-cone. Especially if there is a big discrepancy like 3 or 4 times more between arterial diameters old cone-shaping technique is not very practical and also time consuming. In such circumstances I like to make the larger diameter artery cone-shaped using the vessel ligature clips. I apply the clip to the artery end wall from outside with approximately 30 degree angle Figure 1-3: Apply the clip to the artery end wall from outside with approximately 30 degree angle to its longitudinal axis. Figure 4: Double small size clip.

Clinics in Surgery Clinical Imageclinicsinsurgery.com/pdfs_folder/cis-v2-id1651.pdfmiddle size clip is suitable. Also in some cases I use a double small size clip (Figure 4). Applying

Embed Size (px)

Citation preview

Remedy Publications LLC., | http://clinicsinsurgery.com/

Clinics in Surgery

2017 | Volume 2 | Article 16511

Using the Vessel Ligature Clip to Make the Mismatched Hepatic Artery Microsurgical Anastomosis Easier and

Effective

OPEN ACCESS

*Correspondence:Levent Yalçin, Departemnt of

Orthopaedics and Traumatology, Selcuk University, Konya, Sakayik sokak No: 58/1 Nisantasi, İstanbul, Turkey, Tel:

905322134589;E-mail: [email protected]

Received Date: 10 Jul 2016Accepted Date: 25 Sep 2017Published Date: 05 Oct 2017

Citation: Yalçin L. Using the Vessel Ligature Clip to Make the Mismatched Hepatic Artery

Microsurgical Anastomosis Easier and Effective. Clin Surg. 2017; 2: 1651.

Copyright © 2017 Levent Yalçin. Ghanem. This is an open access

article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution,

and reproduction in any medium, provided the original work is properly

cited.

Clinical ImagePublished: 05 Oct, 2017

Levent Yalçin*

Departemnt of Orthopaedics and Traumatology, Selcuk University, Konya, Turkey

Clinical ImageThere are some specific challenges in microsurgical anastomosis of mismatched Hepatic

Arteries in Living Donor Liver Transplantation. Hepatic Artery anastomosis is an important part of the Liver Transplantation from living donor [1,2]. Mismatching of arterial diameter is not unusual. Most of the arteries could be anastomosed end to end after stretching the artery which has a narrow diameter. Also sometimes doing a very shallow fish mouth incision on the artery which has narrow diameter is very helpful for anastomosing with the other artery. But if mismatching between arterial diameters are more than 30% to 50% these techniques are not enough. Cone-shaping is a well-known technique to make narrow the wide diameter artery to adopt the other one. Classic technique is performed by cutting and suturing the end wall of the artery by creating a semi-cone. Especially if there is a big discrepancy like 3 or 4 times more between arterial diameters old cone-shaping technique is not very practical and also time consuming.

In such circumstances I like to make the larger diameter artery cone-shaped using the vessel ligature clips. I apply the clip to the artery end wall from outside with approximately 30 degree angle

Figure 1-3: Apply the clip to the artery end wall from outside with approximately 30 degree angle to its longitudinal axis.

Figure 4: Double small size clip.

Levent Yalçin Clinics in Surgery - Orthopaedic Surgery

Remedy Publications LLC., | http://clinicsinsurgery.com/ 2017 | Volume 2 | Article 16512

to its longitudinal axis (Figure 1-3). This angle is important to create less jet stream in the anastomosis side. In some cases, applying a one middle size clip is suitable. Also in some cases I use a double small size clip (Figure 4). Applying the safety sutures to prevent unexpected movement of the clip could also be recommended. There is not any knowledge about this technique in the literature. The advantages of this technique are that it consumes less time and also less arterial ischemia for transplanted liver.

References1. Alper M, Gundogan H, Tokat C, Ozek C. Microsurgical reconstruction

of hepatic artery during living donor liver transplantation. Microsurgery. 2005;25(5):378-83.

2. Piskin T, Demirbas T, Yalcin L, Yaprak O, Dayangac M, Guler N, et al. Recipient splenic artery utilization for arterial re-anastomosis in living donor liver transplantation: single-center experience. Hepatogastroenterology. 2012;59(116):1263-4.