2
FOR ANY QUESTIONS OR COMMENTS, PLEASE CONTACT AN ALECO REPRESENTATIVE 2720 E. Avalon Ave. Muscle Shoals, AL 35661 Phone (256) 248-2402 or toll free 1-800-633-3120 Fax: 1-800-750-9616 email: [email protected] Diagram 1 Side View Wall Lag Screw MaxBullet® Hardware Bracket Bullet Seal opening here Strips Diagram 2 Front View w/ Strip Spacing D i a g r a m 3 Clear-Flex II ® Strip Door Installation Instructions (Food Service Model) Using the Maximus System Hardware TOOLS NEEDED Pen or Pencil to Mark Drill Holes * Drill 5/16 Di ameter Fasteners Step Stool or Ladder Utility Knife to Cut Strips IMPORTANT Prior to installation, unroll all door strips and place them on a clean, flat surface in a warm atmosphere for a minimum of twenty-four (24) hours. This will allow the strips to return to their original form. 1. Mount the MaxBullet® hardware bracket using lag screws provided on the inside wall of walk-in, centered appropriately above conventional door opening. 2. Seal opening at ends of MaxBullet® hardware bracket with NSF-approved silicone sealant (Diagram 1). 3. Press the door strips onto the “bullets” of the hardware bracket making certain that the concave sides are facing each other (Diagram 3). Attach strip numbers 1 and 3 (see Diagram 2) with concave side toward you, leaving desired spacing between strips as indicated by the diagram on reverse side of this sheet. Then attach strip number 2 with concave side away from you. Proceed with strip number 5 toward you, again leaving the appropriate spacing as per diagram on reverse side of this sheet. Proceed until all strips are in place. 4. Once all of the door strips have been attached, the strips can be trimmed to leave ¼” of clearance from the floor surface. Your PVC door strips may be trimmed by using a common utility knife to score and then be torn by hand. The door strips need to hang for 24 to 48 hours before final trim to allow for proper alignment. * NSF certification applies when hardware is installed with approved low-temp PVC strip material. web: www.aleco.com P/N 477251 (Rev 0511)

Clear-Flex® II with MaxBullet® Mounting System (Food Service)

Embed Size (px)

DESCRIPTION

Clear-Flex® II with MaxBullet® Mounting System (Food service)

Citation preview

Page 1: Clear-Flex® II with MaxBullet® Mounting System (Food Service)

FOR ANY QUESTIONS OR COMMENTS, PLEASE CONTACT AN ALECO REPRESENTATIVE 2720 E. Avalon Ave. Muscle Shoals, AL 35661 � Phone (256) 248-2402 or toll free 1-800-633-3120

Fax: 1-800-750-9616 � email: [email protected]

Diagram 1 Side View

Wall Lag Screw MaxBullet® Hardware Bracket Bullet Seal opening here Strips

Diagram 2

Front View w/ Strip Spacing

Diagram 3

Clear-Flex II® Strip Door Installation Instructions (Food Service Model) Using the Maximus System Hardware

TOOLS NEEDED• Pen or Pencil to Mark Drill Holes * • Drill • 5/16 Di ameter Fasteners • Step Stool or Ladder • Utility Knife to Cut Strips IMPORTANTPrior to installation, unroll all door strips and place them on a clean, flat surface in a warm atmosphere for a minimum of twenty-four (24) hours. This will allow the strips to return to their original form. 1. Mount the MaxBullet® hardware bracket

using lag screws provided on the inside wall of walk-in, centered appropriately above conventional door opening.

2. Seal opening at ends of MaxBullet®

hardware bracket with NSF-approved silicone sealant (Diagram 1).

3. Press the door strips onto the “bullets” of the

hardware bracket making certain that the concave sides are facing each other (Diagram 3). Attach strip numbers 1 and 3 (see Diagram 2) with concave side toward you, leaving desired spacing between strips as indicated by the diagram on reverse side of this sheet. Then attach strip number 2 with concave side away from you. Proceed with strip number 5 toward you, again leaving the appropriate spacing as per diagram on reverse side of this sheet. Proceed until all strips are in place.

4. Once all of the door strips have been

attached, the strips can be trimmed to leave ¼” of clearance from the floor surface. Your PVC door strips may be trimmed by using a common utility knife to score and then be torn by hand. The door strips need to hang for 24 to 48 hours before final trimto allow for proper alignment.

* NSF certification applies when hardware is installed with approved low-temp PVC strip material.

� web: www.aleco.com

P/N 477251 (Rev 0511)

Page 2: Clear-Flex® II with MaxBullet® Mounting System (Food Service)

STRIP PLACEMENT GUIDE

PARTIAL OVERLAP FULL OVERLAP

6” WIDE MATERIAL

FULL OVERLAP 100% PARTIAL OVERLAP 66%

PARTIAL OVERLAP 50%

8” WIDE MATERIAL

FULL OVERLAP 100%

FULL OVERLAP 100%PARTIAL OVERLAP 66% (4”) PARTIAL OVERLAP 33% (2”)

12” WIDE MATERIAL

FULL OVERLAP 100%

16” WIDE MATERIAL

PARTIAL OVERLAP 75% (6”) PARTIAL OVERLAP 50% (4”) PARTIAL OVERLAP 25% (2”)

Specially formulated Vinyl Strip Cleaner available exclusively through your local Aleco distributor.