Clean andCooling Rack
CNCR Co., Ltd. pledges to protect our customers’ servers and communication devices by providing products with the utmost quality and service.
pledges to protecct our custcts with th
pppledges to protecproviding produc
tomers servers and communicationand service.
te
servers at quality
tomers se utmos
ISO 9001 Certificate of patent
Company Introduction and Certifications
Major Company History
2008Counducted R&D for G.Rack
Patent registered for heat recovery system
2003Established Shin Poong Air Conditioning
2006Converted to a corporation named SP IndustrialTechnologies Co., Ltd.
2010Patent registered for G.Rack
2012Participated in World IT show 2012
Established CNCR Co., Ltd. that specializesin manufacturing and selling G.Rack
2013Factory moved (to 1261-4 Daejeo 2-dong,Gangseo-gu, Busan)
Participated in Hi-tech Defense Industry Fair 2013
Participated in World IT Show 2013
2015Participated in World IT Show 2015
Patent registered for EMP protection rack
Acquired CE certification
Acquired KC certification
Selected as a 2015 priority purchase recommendedproduct for excellent invetion - Korea InventionPromotion Assocication
Participated in the Enviroment and Energy Tech(ENTECH) 2015
PCT international application(Application number. PCT/KR2015/006613)
2014Automatic fire extinguisher for server racks
Constant temperature rack control system
Protective safety device for in-rack devices
Additional patents registerd
Participated in the 18th International Conferenceon Accelerator & Beam Utilization
Participated in World IT Show 2014
ISO9001 certification
Industrial R&D Center certification
Venture Corporation Certification
KAIST
JEONJU UNIVERSITY
SOONGSIL UNIVERSITY
Seoul National University
GIST
Korea Aerospace Research Institute
KOREA INSTITUTE OF MARITIME AND
FISHERIES TECHNOLOGY
Korea Institute of Ocean Science & Technology
POHANG ACCELERATOR LABORATORY
Korea University of Technology and Education
DGIST
The Academy of Korean Studies
Institute for Basic Science
SUNGKYUNKWANUNIVERSITY
Sunchon National University
Gachon University
KOREA INSURANCEINSTITUTE
Educationalinstitution& Laboratory
UAMCO
GANGNAM SEVERANCE HOSPITAL
NEOLINE CREDIT
NONGHYUPHANARO CLUB
IBK INSURANCE
YONSEI UNIVERSITYHEALTH SYSTEM
MOUNTAIN TV
LG-N Sys Inc
Gwacheon PresbyterianChurch
LIG System
WISDOMHOUSE inc.
Daishin AMC
JT Chinae Savings Bank
Sportstoto
DIGITAL CHOSUN INC
KOREA APPRAISALCO., LTD
NONGHYUP FARMER'SMARKET
Financial & Medicalpractice etc.Public institution
Jongno-gu Office
Miryang City Hall
Dongducheon City Hall
Gori Nuclear Power Division KEPCO
Incheon Foundationof Women & Family
Port of Gunsan
Sejong City WaterRestoration Center
Namyangju, Water and Sewage Management Center
Icheon FMC
Busan InfrastructureCorporation
East Sea FisheriesManagement Service
Ministry of Unification
Korea Labor Foundation
Gyeongju City Hall
Naju City Hall
Korea AirportsCorporation
Gijang Country Office
MANN+HUMMEL
HYUNDAI MOTORCOMPANY
Samsung Heavy Industries co., Ltd.
Samsung Electronics Co., Ltd.
Suprema
KOLON Corporation
LG Electronics Inc.
Hyundai-Steel Co., Ltd.
Dongkook Ind.co., Ltd.
Fauresia
HEESUNG METAL LTD.
SOMO GROUP.
COWAY CO., LTD.
Azbil Korea Co., Ltd.
PHONAK KOREA
Neo ICP Korea Inc.
SAMSUNG BIOLOGICS
Manufacturingindustry
Major Achievements
04
G.Rack, the optimum solution for the server room
With G.Rack, users do not need to set up an server room anduse a precision air conditioner.
Saves energy by maintaining constant temperature andhumidity for each rack unit.
No need for a water supply pipe to maintain humidity.Easy to install and easy to operate.
The rack’s sealed inner structure prevents the entrance of dust andscreens out noises generated from the server & network equipment.
Remote monitoring of in-rack temperature and humidity andserver’s status
Equipped with protective devices for in-rack servers andwith fire extinguishers.
SMS alert service in the case of overheating or sever network failure
Major functions of G.Rack, the optimum server room for IT device management
Ordinary Server Room Server room with G.Rack
· Requires a separate space for managing server & network equipment
· Needs to increase the capacity of precision air conditioner
· Requires a highly priced precision air conditioner
· High electricity costs due to complete cooling of the room
· Hard to prevent the entry of dust completely
· Limited installation of precision air conditioners
· Requires many subsidiary facilities
· Stiil has a risk factor of freezing and bursting or water flowing backward in the water supply pipe
· High initial investment and maintenance costs
· A separate environmental monitoring system for server room required
· Requires a space to accommodate the size of the G.Rack
· Requires additional G.Rack only in the case of the installation of new equipment
· No additional construction required as G.Rack has its own precision air conditioner.
· Low electricity charge as only the inside of the sealed rack is cooled
· Completely prevents the entry of dust
· Free of noises from server & network equipment
· Unconstrained installation with no space constraints
· Special feature of maintaining constant humidity with no water supply pipe required.
· Very low costs of initial investment and maintenance
· Provides a remote monitoring system by default
05
Functions of G.Rack
Comparison of electricity consumption between G. Rack and other precision air conditioners
Discharge of external air
Circulation of internal air
Inlet of external air(circulation of the external air)
Precision air conditioner for rack unit
Low power, high efficiency precision air conditioner
Maintaining constant temperature and humidity as well as dustproof features - the essential elements of the management of server & network equipment
Target of temperatureand humidity control
Heat of the in-rack server
Example. Comparison of electricity consumption when 6 units of 2U servers (650W) are used Total heat dissipation of servers: 3,900W
Whole server room including servers
G.Rack Precision air conditioners
Power consumption 1.5kW (for one G. Rack) 13.8kW (3R/T, minimum capacity)
Yearly electricity charge About 1 million KRW About 9 million KRW
Saving when G. Rack is used
* Electricity costs are calculated based on an average load rate of 100% and 24-hour operation.
*If constant temperature and humidity are not maintained or dust proofing is not present,data loss in the servers or communication errors in the network devices may occur.
About 8 million KRW
Constant temperature
-High temperature is generated by MIS equipment during operation
-The temperature of the electrical circuits has to be maintained constantly to minimize erroneous operations
Constant humidity
-Excessive humidity promotes the oxidization of metals.
-Low humidity may cuase static electricity and damage to circuit elements.
Dust proofing
-Accumulated dust may cause errone-ous operation of the server & network equipment as dust reduces cooling efficiency and accelerates rise in temperature
-Risk of fire as dust may cause static electricity, sparks, etc.
Inlet of external air
Existing precision air conditioners incur large energy losses as they cool the whole server room down to
reduce the heat generated by the server & network equipment.
In contrast, G. Rack offers high efficiency temperature and humidity level maintenance using low power,
as it is designed to cool down the heat of only the in-rack server & network equipment of which the temperature level needs to be maintained optimally.
This system safely protects the in-rack server and communication devices as the temperature of any spot
inside the rack is constantly maintained, and dust is blocked by the sealing, as the temperature and humidity
of the in-rack server and communication devices are protected by a sealed circulating duct.
Discharge of external air
Sealed circulation of air inside the rack module
Constanttemperature and humidity as well as sealing against dust
06
Offers a touch screen panel
G.Rack Smart Grid
Operation screen Recording screen
Set temperature In-rack device monitoring
In-rack device operatingcurrent (heat generation rate)
G. Rack operating current
Amount of energy savings
In-rack device monitoring
Normal operation
Faulty operation
Type. A
Type. B
Response speed
Type. C
G. Rack allows users to check the operating status and other data of the in-rack server & network equipment
without needing to open the rack door.
G. Rack provides the next generation intelligent grid functions that optimize energy efficiency by displaying
its power consumption and that of the in-rack server as well as of the network devices on the front panel.
It offers convenience of operation and offers various data to users.
07
Temperature and humidity control and monitoring system
Integrated management system
In-rack remote monitoring server offered as default
ManagerFacility sensor
Facility Management System
AccessAir
conditioner
UPS Firefighting
Water leakPowersource
Temperature/ humidity
Power generator
Intergrated management system
Equipped with monitoring programs, such as network monitoring, server monitoring and server room facility
monitoring, G. Rack offers an computing environment monitoring service for customer companies.
This system allows users to monitor the rack status using a mobile device or dedicated monitoring system.
08
Alarm (SMS) function
Administrator program
작동화면
Alarm (SMS) function
Alarm for in-rack status Alarm for weekly statistics Alarm for networkabnormality
Alarm for device checkup
This is an alarm function using a touch pad, a dedicated program and SMS that sends an alert in case that
the inside of the rack begins to overheat or an abnormality occurs in an in-rack device (server, storage and
network device).
G. Rack offers an administrator program that allows users to control and manage it or monitor its status.
Administratormenu
Administratorprogram
Administratorlogin screen
Setup function
Login/ temperature log
Temperaturestatistics function
09
Applications of G. Rack
An server room equipped with precision air conditioner, fire extinguishing facility and other subsidiary facilities
is set up to run a massive server system for the headquarters of a national or regional level public institute.
Institutions or offices under immediate control operate a small-sized system with one or two racks to install
a data server for storing data and communication devices to interface with the headquarters for conducting
work.
Frequent system failures occur due to high ambient temperatures and accumulated dust as the system is left
unattended in document storage rooms, meeting rooms, etc., due to insufficient space to set up an server room or
the high cost of investment for the facility of a small-sized system.
Due to inferior device management in institutions or offices under immediate control, a disruption of communication
in a well-equipped government information service or national war command network, etc. is caused, which
leads to work discontinuation, inability to handle an emergency or civil complaints.
Ex) Providential government offices, community centers in Eub, Myeon or Dong, local government offices,
patrol divisions, 119 fire houses, health centers, regional post offices, etc.
G. Rack, an affordable temperature and humidity maintenance and dust proof system for each rack unit,
enables the stable system operation of public institutes, national defense institutes, traffic systems,
financial institutes, schools and business entities by solving the problem of insufficient space when setting
up server rooms, and allows users to maintain optimum temperature and humidity, as well as prevent
dust from entering into the server & network system.
Like public institutes, every bank sets up and manages an IDC or server room at its headquarters.
Branch offices of banks across the nation operate small-scale systems (servers, communication devices,
CCTVs and recording devices), which tend to be left unattended in a temporary room with no precision air
conditioning facility.
Internet disruption occurs due to reduced communication speed caused by overheating and accumulated dust.
Inefficiencies are caused by the work delays of customer service staff.
All of these lead to customer dissatisfaction, which lowers the company’s credibility.
Branch offices of companies, companies in high-rise buildings, and offices in production processes normally
operate a small-sized system with one or two racks after installing a data server for storing data and installing
communication devices, but the system tends to be left unattended in a temporary room, meeting room or
office pantry, causing frequent system failures due to high temperature or accumulated dust.
An office in a high-rise building especially requires a separate dedicated cooling system for an server & network
system in preparation for extra work hours and the shutdown of central air conditioning systems. But, such
cooling system may be not installed since there is no space for outdoor unit of the cooling system and the
difficulty of piping construction.
Railways and subways are operated by signal communication systems that are based on server & network systems.
Devices for signal communication are installed and operated at a communication center at each station.
However, system failures occur due to accumulated dust.
As device failures occur frequently, the signal communication system cannot operate properly, causing failures
in the operating railways and subway trains, and may cause a large-scale accident.
Railways and subway stations
Companies
Financial sector
Public institutes
10
Installation of G. Rack
(no need to setup an MIS room)
Precision air conditioner foreach rack unit
(monitoring the network statusof in-rack server, remote monitoring
and alarm service)
provision of stableserver & networkenvironment
Ordinary server room
(in the case of no precisionair conditioner)
Risk of server system failures
(temperature / humiditycontrol issue, overheating)
+other various associated risks
(a short circuit or line failurecaused by the entrance of dust)
Before
Sites where precision air conditioners and air-conditioners cannot be installed properly to remove overheating in the server or network device
Sites where there is not enough space for setting up an server room, communication center and server room
Sites where measures to stop the entrance of dust need to be set up
Sites where a precision air conditioner needs to be installed with no resident administrator
Sites where energy savings need to be implemented
Businesses that operate small-scale server & network systems
Improved
GANGNAM SEVERANCE HOSPITAL
Seongbuk-dong, Naju-si, community centerKorea Labor Foundation Seoul National UniversityKOLON Corporation
The Academy ofKorean Studies
·Offices in a high-rise building, office buildings, production process offices in factories, financial institutes
(bank branch offices), etc.
·Offices in production process, general offices, hospitals, schools, etc.
·Communication center at a subway station, server room with frequent access
·Unmanned base stations, MDF/IDF inside a building
·Public institutes, schools, factories that are required to reduce greenhouse gas emissions, etc.
11
Structure of G. Rack
Outside view
12
10
11
15
13
14
8
4
3
2
1
5
6
7
9
Frontal outside view
1. Upper cable inlet part 2. Upper safety device for protecting the inside 3. Fire extinguisher 4. Rack module 5. Control buttons 6. Control screen 7. Safety device for protecting the inside 8. Precision air conditioning module 9.caster
Rear outside view
10. Upper safety device for protecting the inside 11. Fire extinguisher 12. Upper cable inlet part13. Rack module 14. Lower cable inlet part 15. Precision air conditioning module
12
Detailed drawing of the cable inlet part (Slide closed)
Detailed drawing of the cable inlet part (slide moves)
Detailed drawing of the cable inlet part (slide open)
910
2
1 Convenient cable inlet (Upper part)
A large quantity of communincation cables can be easily introduced from upper cable tray when using the G.Rack upper cable inlet unit.
1.cable 2. Upper cable inlet part
Convenient cable inlet (Lower part)
Cables can be installed inside the G. Rack as they are connected by attaching or detaching the cover of the lower part cable inlet of the G. Rack without disconnecting the cables for the server, communication device and optical cable.
Convenient cable inlet (Lower part)
User can easily insert the cable by using the cable inlet on the lower part of the G. Rack. Users can perfectly seal the inlet cables using the cable finishing material provided with the product and the cable inlet finish slide cover.
9. Cable inlet 10. Slide cover for cable inlet finish
3. Cable 4. Inlet part cover 5. Cable finish material (provided with the product) 6. Slide cover for cable inlet finish 7. Cable 8. Cable inlet hole cover
Cable inlet
3
4
5
6
7
8
13
An upper cover of internal protection safety apparatus is opened.
Heat inside G.Rack is forcibly discharged by safety exhaust fan.
A front cover of internal protection safety apparatus is opened.
Connect to UPS power source(Connect UPS power line to generalpower source when there is no UPS.)
Connect main power line togeneral power source.
Safety device – for protecting the inside
Safety device – UPS for power outage
Safety device
emission of internal thermal
Inlet of external air
The internal protection safety apparatus is an apparatus enabling a normal operation without any problem on the server or communication devices by forcibly discharging heat generated by the server or communication devices when thermo-hygrostat module of G.Rack becomes inoperative due to power failure or other causes.
The in-rack server of G. Rack can be protected better against a power outage as its RCU (remote monitoring device) and safety device for protecting the inside starts to operate by a UPS. Since the RCU and the safety device for protecting the inside consume almost no power, users do not need to increase the capacity of their existing UPSs.
14
Safety device – Fire Pack( fire extinguishing equipment), Option
1
3
2
Safety device
Although computer room and IDC are protected by halogen or CO₂ fire-extinguishing facilites, these facilities are installed outside of server rack, such that it is difficult to perform a quick initial fire extinguishment or a fire diffusion prevention when there occurs a fire in communication device. However, G.Rack Fire Pack is installed inside the G.Rack to enable a quick initial fire extinguishment and fire diffusion prevention when there occurs a fire in internal server or communication device, whereby damage by fire can be reduced (Self power generating sensor)
G.Rack Fire Pack is a fire extinguisher harmless to human as a Fixed Condensed Aerosol fire extinguisher unlike halogen or CO₂ and stored in solid state to be free from leakage unlike the conventional fire extinguisher. Furthermore, it is possible to operate electronic devices or server during operation without any problems. Unlike the conventional fire extinguisher, G.Rack Fire Pack is a fire extinguisher that needs no separate detector or electronic devices requiring electric power, and integrally operates due to self electric generation without any replacement of detector.
1. Fire Pack(fire extinguishing equipment, Option) 2. Self power generating sensor3. Fixed Condensed Aerosol
15
Usable Unit 27U / 36U
Hiehgt 75in(1,895mm) / 90in(2,295mm)
Width 29in(730mm)
Depth 46in(1,158mm)
Power consumption 1.5 KW
Cooling capacity 4,000W(13,000BTU)
Color
Non-standard product line-up
Product dimensions
Simple installation with a single cordProvides a pleasant server & network environmentThe only patented product of its kind in the world
Optimum solution for server and network device operation
Racks customized by site conditions and device usage, such as anti-vibration rack, rack for vessel, rack for
outdoor use, CCTV rack, etc., are available on order.
www.grack.net