Clean and Cooling Rack

Clean and Cooling Rack Rack_brochure_2015.pdf · · Stiil has a risk factor of freezing and bursting or water flowing backward in the water supply pipe · High initial investment

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Clean and Cooling Rack Rack_brochure_2015.pdf · · Stiil has a risk factor of freezing and bursting or water flowing backward in the water supply pipe · High initial investment

Clean andCooling Rack

Page 2: Clean and Cooling Rack Rack_brochure_2015.pdf · · Stiil has a risk factor of freezing and bursting or water flowing backward in the water supply pipe · High initial investment

CNCR Co., Ltd. pledges to protect our customers’ servers and communication devices by providing products with the utmost quality and service.

pledges to protecct our custcts with th

pppledges to protecproviding produc

tomers servers and communicationand service.

te

servers at quality

tomers se utmos

ISO 9001 Certificate of patent

Company Introduction and Certifications

Major Company History

2008Counducted R&D for G.Rack

Patent registered for heat recovery system

2003Established Shin Poong Air Conditioning

2006Converted to a corporation named SP IndustrialTechnologies Co., Ltd.

2010Patent registered for G.Rack

2012Participated in World IT show 2012

Established CNCR Co., Ltd. that specializesin manufacturing and selling G.Rack

2013Factory moved (to 1261-4 Daejeo 2-dong,Gangseo-gu, Busan)

Participated in Hi-tech Defense Industry Fair 2013

Participated in World IT Show 2013

2015Participated in World IT Show 2015

Patent registered for EMP protection rack

Acquired CE certification

Acquired KC certification

Selected as a 2015 priority purchase recommendedproduct for excellent invetion - Korea InventionPromotion Assocication

Participated in the Enviroment and Energy Tech(ENTECH) 2015

PCT international application(Application number. PCT/KR2015/006613)

2014Automatic fire extinguisher for server racks

Constant temperature rack control system

Protective safety device for in-rack devices

Additional patents registerd

Participated in the 18th International Conferenceon Accelerator & Beam Utilization

Participated in World IT Show 2014

ISO9001 certification

Industrial R&D Center certification

Venture Corporation Certification

Page 3: Clean and Cooling Rack Rack_brochure_2015.pdf · · Stiil has a risk factor of freezing and bursting or water flowing backward in the water supply pipe · High initial investment

KAIST

JEONJU UNIVERSITY

SOONGSIL UNIVERSITY

Seoul National University

GIST

Korea Aerospace Research Institute

KOREA INSTITUTE OF MARITIME AND

FISHERIES TECHNOLOGY

Korea Institute of Ocean Science & Technology

POHANG ACCELERATOR LABORATORY

Korea University of Technology and Education

DGIST

The Academy of Korean Studies

Institute for Basic Science

SUNGKYUNKWANUNIVERSITY

Sunchon National University

Gachon University

KOREA INSURANCEINSTITUTE

Educationalinstitution& Laboratory

UAMCO

GANGNAM SEVERANCE HOSPITAL

NEOLINE CREDIT

NONGHYUPHANARO CLUB

IBK INSURANCE

YONSEI UNIVERSITYHEALTH SYSTEM

MOUNTAIN TV

LG-N Sys Inc

Gwacheon PresbyterianChurch

LIG System

WISDOMHOUSE inc.

Daishin AMC

JT Chinae Savings Bank

Sportstoto

DIGITAL CHOSUN INC

KOREA APPRAISALCO., LTD

NONGHYUP FARMER'SMARKET

Financial & Medicalpractice etc.Public institution

Jongno-gu Office

Miryang City Hall

Dongducheon City Hall

Gori Nuclear Power Division KEPCO

Incheon Foundationof Women & Family

Port of Gunsan

Sejong City WaterRestoration Center

Namyangju, Water and Sewage Management Center

Icheon FMC

Busan InfrastructureCorporation

East Sea FisheriesManagement Service

Ministry of Unification

Korea Labor Foundation

Gyeongju City Hall

Naju City Hall

Korea AirportsCorporation

Gijang Country Office

MANN+HUMMEL

HYUNDAI MOTORCOMPANY

Samsung Heavy Industries co., Ltd.

Samsung Electronics Co., Ltd.

Suprema

KOLON Corporation

LG Electronics Inc.

Hyundai-Steel Co., Ltd.

Dongkook Ind.co., Ltd.

Fauresia

HEESUNG METAL LTD.

SOMO GROUP.

COWAY CO., LTD.

Azbil Korea Co., Ltd.

PHONAK KOREA

Neo ICP Korea Inc.

SAMSUNG BIOLOGICS

Manufacturingindustry

Major Achievements

Page 4: Clean and Cooling Rack Rack_brochure_2015.pdf · · Stiil has a risk factor of freezing and bursting or water flowing backward in the water supply pipe · High initial investment

04

G.Rack, the optimum solution for the server room

With G.Rack, users do not need to set up an server room anduse a precision air conditioner.

Saves energy by maintaining constant temperature andhumidity for each rack unit.

No need for a water supply pipe to maintain humidity.Easy to install and easy to operate.

The rack’s sealed inner structure prevents the entrance of dust andscreens out noises generated from the server & network equipment.

Remote monitoring of in-rack temperature and humidity andserver’s status

Equipped with protective devices for in-rack servers andwith fire extinguishers.

SMS alert service in the case of overheating or sever network failure

Major functions of G.Rack, the optimum server room for IT device management

Ordinary Server Room Server room with G.Rack

· Requires a separate space for managing server & network equipment

· Needs to increase the capacity of precision air conditioner

· Requires a highly priced precision air conditioner

· High electricity costs due to complete cooling of the room

· Hard to prevent the entry of dust completely

· Limited installation of precision air conditioners

· Requires many subsidiary facilities

· Stiil has a risk factor of freezing and bursting or water flowing backward in the water supply pipe

· High initial investment and maintenance costs

· A separate environmental monitoring system for server room required

· Requires a space to accommodate the size of the G.Rack

· Requires additional G.Rack only in the case of the installation of new equipment

· No additional construction required as G.Rack has its own precision air conditioner.

· Low electricity charge as only the inside of the sealed rack is cooled

· Completely prevents the entry of dust

· Free of noises from server & network equipment

· Unconstrained installation with no space constraints

· Special feature of maintaining constant humidity with no water supply pipe required.

· Very low costs of initial investment and maintenance

· Provides a remote monitoring system by default

Page 5: Clean and Cooling Rack Rack_brochure_2015.pdf · · Stiil has a risk factor of freezing and bursting or water flowing backward in the water supply pipe · High initial investment

05

Functions of G.Rack

Comparison of electricity consumption between G. Rack and other precision air conditioners

Discharge of external air

Circulation of internal air

Inlet of external air(circulation of the external air)

Precision air conditioner for rack unit

Low power, high efficiency precision air conditioner

Maintaining constant temperature and humidity as well as dustproof features - the essential elements of the management of server & network equipment

Target of temperatureand humidity control

Heat of the in-rack server

Example. Comparison of electricity consumption when 6 units of 2U servers (650W) are used Total heat dissipation of servers: 3,900W

Whole server room including servers

G.Rack Precision air conditioners

Power consumption 1.5kW (for one G. Rack) 13.8kW (3R/T, minimum capacity)

Yearly electricity charge About 1 million KRW About 9 million KRW

Saving when G. Rack is used

* Electricity costs are calculated based on an average load rate of 100% and 24-hour operation.

*If constant temperature and humidity are not maintained or dust proofing is not present,data loss in the servers or communication errors in the network devices may occur.

About 8 million KRW

Constant temperature

-High temperature is generated by MIS equipment during operation

-The temperature of the electrical circuits has to be maintained constantly to minimize erroneous operations

Constant humidity

-Excessive humidity promotes the oxidization of metals.

-Low humidity may cuase static electricity and damage to circuit elements.

Dust proofing

-Accumulated dust may cause errone-ous operation of the server & network equipment as dust reduces cooling efficiency and accelerates rise in temperature

-Risk of fire as dust may cause static electricity, sparks, etc.

Inlet of external air

Existing precision air conditioners incur large energy losses as they cool the whole server room down to

reduce the heat generated by the server & network equipment.

In contrast, G. Rack offers high efficiency temperature and humidity level maintenance using low power,

as it is designed to cool down the heat of only the in-rack server & network equipment of which the temperature level needs to be maintained optimally.

This system safely protects the in-rack server and communication devices as the temperature of any spot

inside the rack is constantly maintained, and dust is blocked by the sealing, as the temperature and humidity

of the in-rack server and communication devices are protected by a sealed circulating duct.

Discharge of external air

Sealed circulation of air inside the rack module

Constanttemperature and humidity as well as sealing against dust

Page 6: Clean and Cooling Rack Rack_brochure_2015.pdf · · Stiil has a risk factor of freezing and bursting or water flowing backward in the water supply pipe · High initial investment

06

Offers a touch screen panel

G.Rack Smart Grid

Operation screen Recording screen

Set temperature In-rack device monitoring

In-rack device operatingcurrent (heat generation rate)

G. Rack operating current

Amount of energy savings

In-rack device monitoring

Normal operation

Faulty operation

Type. A

Type. B

Response speed

Type. C

G. Rack allows users to check the operating status and other data of the in-rack server & network equipment

without needing to open the rack door.

G. Rack provides the next generation intelligent grid functions that optimize energy efficiency by displaying

its power consumption and that of the in-rack server as well as of the network devices on the front panel.

It offers convenience of operation and offers various data to users.

Page 7: Clean and Cooling Rack Rack_brochure_2015.pdf · · Stiil has a risk factor of freezing and bursting or water flowing backward in the water supply pipe · High initial investment

07

Temperature and humidity control and monitoring system

Integrated management system

In-rack remote monitoring server offered as default

ManagerFacility sensor

Facility Management System

AccessAir

conditioner

UPS Firefighting

Water leakPowersource

Temperature/ humidity

Power generator

Intergrated management system

Equipped with monitoring programs, such as network monitoring, server monitoring and server room facility

monitoring, G. Rack offers an computing environment monitoring service for customer companies.

This system allows users to monitor the rack status using a mobile device or dedicated monitoring system.

Page 8: Clean and Cooling Rack Rack_brochure_2015.pdf · · Stiil has a risk factor of freezing and bursting or water flowing backward in the water supply pipe · High initial investment

08

Alarm (SMS) function

Administrator program

작동화면

Alarm (SMS) function

Alarm for in-rack status Alarm for weekly statistics Alarm for networkabnormality

Alarm for device checkup

This is an alarm function using a touch pad, a dedicated program and SMS that sends an alert in case that

the inside of the rack begins to overheat or an abnormality occurs in an in-rack device (server, storage and

network device).

G. Rack offers an administrator program that allows users to control and manage it or monitor its status.

Administratormenu

Administratorprogram

Administratorlogin screen

Setup function

Login/ temperature log

Temperaturestatistics function

Page 9: Clean and Cooling Rack Rack_brochure_2015.pdf · · Stiil has a risk factor of freezing and bursting or water flowing backward in the water supply pipe · High initial investment

09

Applications of G. Rack

An server room equipped with precision air conditioner, fire extinguishing facility and other subsidiary facilities

is set up to run a massive server system for the headquarters of a national or regional level public institute.

Institutions or offices under immediate control operate a small-sized system with one or two racks to install

a data server for storing data and communication devices to interface with the headquarters for conducting

work.

Frequent system failures occur due to high ambient temperatures and accumulated dust as the system is left

unattended in document storage rooms, meeting rooms, etc., due to insufficient space to set up an server room or

the high cost of investment for the facility of a small-sized system.

Due to inferior device management in institutions or offices under immediate control, a disruption of communication

in a well-equipped government information service or national war command network, etc. is caused, which

leads to work discontinuation, inability to handle an emergency or civil complaints.

Ex) Providential government offices, community centers in Eub, Myeon or Dong, local government offices,

patrol divisions, 119 fire houses, health centers, regional post offices, etc.

G. Rack, an affordable temperature and humidity maintenance and dust proof system for each rack unit,

enables the stable system operation of public institutes, national defense institutes, traffic systems,

financial institutes, schools and business entities by solving the problem of insufficient space when setting

up server rooms, and allows users to maintain optimum temperature and humidity, as well as prevent

dust from entering into the server & network system.

Like public institutes, every bank sets up and manages an IDC or server room at its headquarters.

Branch offices of banks across the nation operate small-scale systems (servers, communication devices,

CCTVs and recording devices), which tend to be left unattended in a temporary room with no precision air

conditioning facility.

Internet disruption occurs due to reduced communication speed caused by overheating and accumulated dust.

Inefficiencies are caused by the work delays of customer service staff.

All of these lead to customer dissatisfaction, which lowers the company’s credibility.

Branch offices of companies, companies in high-rise buildings, and offices in production processes normally

operate a small-sized system with one or two racks after installing a data server for storing data and installing

communication devices, but the system tends to be left unattended in a temporary room, meeting room or

office pantry, causing frequent system failures due to high temperature or accumulated dust.

An office in a high-rise building especially requires a separate dedicated cooling system for an server & network

system in preparation for extra work hours and the shutdown of central air conditioning systems. But, such

cooling system may be not installed since there is no space for outdoor unit of the cooling system and the

difficulty of piping construction.

Railways and subways are operated by signal communication systems that are based on server & network systems.

Devices for signal communication are installed and operated at a communication center at each station.

However, system failures occur due to accumulated dust.

As device failures occur frequently, the signal communication system cannot operate properly, causing failures

in the operating railways and subway trains, and may cause a large-scale accident.

Railways and subway stations

Companies

Financial sector

Public institutes

Page 10: Clean and Cooling Rack Rack_brochure_2015.pdf · · Stiil has a risk factor of freezing and bursting or water flowing backward in the water supply pipe · High initial investment

10

Installation of G. Rack

(no need to setup an MIS room)

Precision air conditioner foreach rack unit

(monitoring the network statusof in-rack server, remote monitoring

and alarm service)

provision of stableserver & networkenvironment

Ordinary server room

(in the case of no precisionair conditioner)

Risk of server system failures

(temperature / humiditycontrol issue, overheating)

+other various associated risks

(a short circuit or line failurecaused by the entrance of dust)

Before

Sites where precision air conditioners and air-conditioners cannot be installed properly to remove overheating in the server or network device

Sites where there is not enough space for setting up an server room, communication center and server room

Sites where measures to stop the entrance of dust need to be set up

Sites where a precision air conditioner needs to be installed with no resident administrator

Sites where energy savings need to be implemented

Businesses that operate small-scale server & network systems

Improved

GANGNAM SEVERANCE HOSPITAL

Seongbuk-dong, Naju-si, community centerKorea Labor Foundation Seoul National UniversityKOLON Corporation

The Academy ofKorean Studies

·Offices in a high-rise building, office buildings, production process offices in factories, financial institutes

(bank branch offices), etc.

·Offices in production process, general offices, hospitals, schools, etc.

·Communication center at a subway station, server room with frequent access

·Unmanned base stations, MDF/IDF inside a building

·Public institutes, schools, factories that are required to reduce greenhouse gas emissions, etc.

Page 11: Clean and Cooling Rack Rack_brochure_2015.pdf · · Stiil has a risk factor of freezing and bursting or water flowing backward in the water supply pipe · High initial investment

11

Structure of G. Rack

Outside view

12

10

11

15

13

14

8

4

3

2

1

5

6

7

9

Frontal outside view

1. Upper cable inlet part 2. Upper safety device for protecting the inside 3. Fire extinguisher 4. Rack module 5. Control buttons 6. Control screen 7. Safety device for protecting the inside 8. Precision air conditioning module 9.caster

Rear outside view

10. Upper safety device for protecting the inside 11. Fire extinguisher 12. Upper cable inlet part13. Rack module 14. Lower cable inlet part 15. Precision air conditioning module

Page 12: Clean and Cooling Rack Rack_brochure_2015.pdf · · Stiil has a risk factor of freezing and bursting or water flowing backward in the water supply pipe · High initial investment

12

Detailed drawing of the cable inlet part (Slide closed)

Detailed drawing of the cable inlet part (slide moves)

Detailed drawing of the cable inlet part (slide open)

910

2

1 Convenient cable inlet (Upper part)

A large quantity of communincation cables can be easily introduced from upper cable tray when using the G.Rack upper cable inlet unit.

1.cable 2. Upper cable inlet part

Convenient cable inlet (Lower part)

Cables can be installed inside the G. Rack as they are connected by attaching or detaching the cover of the lower part cable inlet of the G. Rack without disconnecting the cables for the server, communication device and optical cable.

Convenient cable inlet (Lower part)

User can easily insert the cable by using the cable inlet on the lower part of the G. Rack. Users can perfectly seal the inlet cables using the cable finishing material provided with the product and the cable inlet finish slide cover.

9. Cable inlet 10. Slide cover for cable inlet finish

3. Cable 4. Inlet part cover 5. Cable finish material (provided with the product) 6. Slide cover for cable inlet finish 7. Cable 8. Cable inlet hole cover

Cable inlet

3

4

5

6

7

8

Page 13: Clean and Cooling Rack Rack_brochure_2015.pdf · · Stiil has a risk factor of freezing and bursting or water flowing backward in the water supply pipe · High initial investment

13

An upper cover of internal protection safety apparatus is opened.

Heat inside G.Rack is forcibly discharged by safety exhaust fan.

A front cover of internal protection safety apparatus is opened.

Connect to UPS power source(Connect UPS power line to generalpower source when there is no UPS.)

Connect main power line togeneral power source.

Safety device – for protecting the inside

Safety device – UPS for power outage

Safety device

emission of internal thermal

Inlet of external air

The internal protection safety apparatus is an apparatus enabling a normal operation without any problem on the server or communication devices by forcibly discharging heat generated by the server or communication devices when thermo-hygrostat module of G.Rack becomes inoperative due to power failure or other causes.

The in-rack server of G. Rack can be protected better against a power outage as its RCU (remote monitoring device) and safety device for protecting the inside starts to operate by a UPS. Since the RCU and the safety device for protecting the inside consume almost no power, users do not need to increase the capacity of their existing UPSs.

Page 14: Clean and Cooling Rack Rack_brochure_2015.pdf · · Stiil has a risk factor of freezing and bursting or water flowing backward in the water supply pipe · High initial investment

14

Safety device – Fire Pack( fire extinguishing equipment), Option

1

3

2

Safety device

Although computer room and IDC are protected by halogen or CO₂ fire-extinguishing facilites, these facilities are installed outside of server rack, such that it is difficult to perform a quick initial fire extinguishment or a fire diffusion prevention when there occurs a fire in communication device. However, G.Rack Fire Pack is installed inside the G.Rack to enable a quick initial fire extinguishment and fire diffusion prevention when there occurs a fire in internal server or communication device, whereby damage by fire can be reduced (Self power generating sensor)

G.Rack Fire Pack is a fire extinguisher harmless to human as a Fixed Condensed Aerosol fire extinguisher unlike halogen or CO₂ and stored in solid state to be free from leakage unlike the conventional fire extinguisher. Furthermore, it is possible to operate electronic devices or server during operation without any problems. Unlike the conventional fire extinguisher, G.Rack Fire Pack is a fire extinguisher that needs no separate detector or electronic devices requiring electric power, and integrally operates due to self electric generation without any replacement of detector.

1. Fire Pack(fire extinguishing equipment, Option) 2. Self power generating sensor3. Fixed Condensed Aerosol

Page 15: Clean and Cooling Rack Rack_brochure_2015.pdf · · Stiil has a risk factor of freezing and bursting or water flowing backward in the water supply pipe · High initial investment

15

Usable Unit 27U / 36U

Hiehgt 75in(1,895mm) / 90in(2,295mm)

Width 29in(730mm)

Depth 46in(1,158mm)

Power consumption 1.5 KW

Cooling capacity 4,000W(13,000BTU)

Color

Non-standard product line-up

Product dimensions

Simple installation with a single cordProvides a pleasant server & network environmentThe only patented product of its kind in the world

Optimum solution for server and network device operation

Racks customized by site conditions and device usage, such as anti-vibration rack, rack for vessel, rack for

outdoor use, CCTV rack, etc., are available on order.

Page 16: Clean and Cooling Rack Rack_brochure_2015.pdf · · Stiil has a risk factor of freezing and bursting or water flowing backward in the water supply pipe · High initial investment

www.grack.net

user
스탬프