AAF Herman Nelson Classmate Conventional Unit Ventilators AH 001 - 008 AV 001-006 Vintage C UAHB, UAHF, UAHR, UAHV 07 - 20 UAVB, UAVR, UAVS, UAVV 07 - 15 Design C (3) Last Manufacture: 2001 Replacement Parts List No. 057115800 Revision R 01/2016 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.DaikinApplied.com

Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

  • Upload
    vuongtu

  • View
    220

  • Download
    6

Embed Size (px)

Citation preview

Page 1: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

AAFHerman Nelson

ClassmateConventional Unit Ventilators

AH 001 - 008AV 001-006

Vintage C

UAHB, UAHF, UAHR, UAHV 07 - 20 UAVB, UAVR, UAVS, UAVV 07 - 15

Design C (3)

Last Manufacture: 2001

Replacement Parts List No. 057115800Revision R 01/2016

To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.DaikinApplied.com

Page 2: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

UV; AH001-008C, UAHX07-20 Des. 3, AV001-006C, UAVX07-15 Des. 3 Rev. R 01/16 RPL 0571158 / Page 2

About the Model Number Changes In 2005 the model numbering nomenclature for the Conventional Unit Ventilators changed:

The AH "C" Vintage unit is now the UAHB Design "C" unit. The AV"C" Vintage unit is now the UAVB Design "C" unit. The unit's components did not change when the nomenclature did (a few engineering changes have taken place since this RPL was last issued, and the part number changes are noted). The complete model number nomenclature currently used has been added to this revision. Unless otherwise noted, all components listed in this revision apply to both the current and the original model numbered units.

ContentsAbout the Model Number Changes .......................................................................................................................................2

Parts List Revision History ...........................................................................................................................3 - 4

Nomenclature Serial Number ................................................................................................................................................ 5 Model Number AH, UAHB, UAHF, UAHR, UAHV ..................................................................................... 5 - 7 Model Number AV, UAVB, UAVR, UAVS, UAVV ..................................................................................... 8 - 10

Adapter Back Kits .............................................................................................................................................11

External Cabinetry AV Cabinet ................................................................................................................................................... 12 AH Cabinet................................................................................................................................................... 13

Fan Section- Motor and Fan Components ...................................................................................................... 14

Electric Heat Electric Heat Elements ................................................................................................................................ 15 Electric Controls .......................................................................................................................................... 15 Coil Section ..............................................................................................................................................16 - 18 Damper Section Drain Pan, and Face & Bypass Damper Components................................................................................. 19 OA & Room Air Damper Components.......................................................................................................... 20

Hydronic Valves and Actuators ........................................................................................................................ 21

Controls PC Board- Main Controllers MicroTech M325 ....................................................................................................................................... 22 Controls By Others ................................................................................................................................... 22 Fuses, Relays, Switches and Time Clock .................................................................................................... 23 Field Installed Accessories Filters .......................................................................................................................................................... 24 Critical Parts List AH 001-008, UAHB, UAHF, UAHR, UUAHV 07-20 ................................................................................ CPL1 AV 001-006, UAVB, UAVR, UAVS, UAVV 07-15 ..................................................................................... CPL2

Page 3: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

UV; AH001-008C, UAHX07-20 Des. 3, AV001-006C, UAVX07-15 Des. 3 Rev. R 01/16 RPL 0571158 / Page 3

Parts List Revision History

Revision Date Description

A 08/11/97 Page 6; AV Top Discharge Grille (Bubble #2) part numbers corrected (all sizes). Page 14; AH Discharge Air Grille (Bubble #2) part numbers corrected (all sizes). B 11/3/97 Page 29; AV/AH Damper Section; Actuator - OA with Linkage (Bubble #1) pn was 4EZB9324. AV/AH Damper Section; Actuator - FBP with Linkage (Bubble #2) pn was 4EZB9324. C 07/98 Page 39; corrected item #110 on 6 fan, 460V. D 05/99 Page 27 - Added description and part number for Auxillary Drain Pans. E 10/99 Added new Page 4 - AV Adapter Back Kits. This resulted in the re-numbering of all later pages. Page 14 - Added footnote for Filter Stop (Bub.# 8). Page 20 - Corrected part number for Bar Grille (Bub.#1) for 6-fan units. Page 22 - Added Blower Assembly. Added column and information for Unit Size 008. Page 23 - Added Bub.# 10 to diagram. Added Motor Gasket part number and description. Page 29 - Updated pn's for Damper Stop, Rear (Bub. 7) on all sizes.Added Seal Strip Gasket pn's, descriptions & footnote. Page 33 - Updated; pn's for Damper - RA (Bub.102) all sizes. Info for Shafts (Bub.111 & 112). Page 43 - Updated info& added foonote for Low Temp. T'Stat, DE Coil (Bub. 34). Added pn & description for Freezestat Clip. Page 48 - Updated pn for Transformer, Motor Speed (Bub.# 51) for 208V, 230V & 265V units. Page 50 - Updated information and added footnote for Fan Relay (Bub.# 74). F 11/99 Page 43 - Added Sampling Chamber Gasket and Sampling Chamber Screw. G 09/00 Page 4 - 3/Fan units; 21.875"Top only pn now 105657001, added new 28" Top Only #106001591. 4/Fan units; 21.875"Top Only pn is now 105657002, added new 28" Top Only pn 106001691. 5/Fan units; 21.875"Top Only pn is now 105657003, added new 28" Top Only pn 106001791. 6/Fan units; 21.875"Top Only pn is now 105657004, added new 28" Top Only pn 106001891. Page 6 - Tinnerman pn changed from 4NKE8447 to 4NKE7968. Page 8 - Bub #2 pn changed from GC10748 to GC10145. Page 10 - Bub #4 part numbers ended in 01, now end in 02. Page 16 - Bub #2 pn changed from GC10748 to GC10145. Page 40 - Bub #111; 265/460/575V TB pn 4ECA8878 changed to 802007686, (9 instances). Page 41- Bub #111; 265/460/575V TB pn 4ECA8878 changed to 802007686, (10 instances). Page 44 - Bub #53; pn 4EPC9056 changed to 060630801. Page 48 - Bub #52; pn 4EPC9056 changed to 060630801. H 08/01 Page 12-'Attaching Parts' screw pn was incorrect, the correct pn is 4SAD3732. I 01/02 Page 44 - Bub #66- Description changed from "Plug & Receptacle Combo to just 'Plug'. J 02/05 Page 22 - Fan Wheel (Plastic) is not included in the Blower Assembly. K 05/05 Page 10 - Bub 37 discharge plenum pn's changed as follows; 4 fan pn changed from 107531902 to 107531901, 5 fan pn changed from 107532002 to 107532001, 6 fan pn changed from 107531102 to 107531101. L 05/11 Reformat to CSIV. Changed title page to reflect new code sheet title-"UAHX, UAVX". Page 2 Added Model Number Note. Pages 4-9 Add code sheets. Add CPL Page 1. M 01/12 Title Page & footer- Change title to AH, UAHB, UAHF, UAHR, UAHV and AV, UAVB, UAVR, UAVS, UAVV. N 09/13 Relinked all drawings. Numerous changes were made. Pages Deleted- Dataplate Location, Sheet metal deleted from External Cabinetry, Touch-up paint, Electrical Data & External Static Pressure Chart, and Diagrams. Delete all Unit Size 001. Title Page - Update to new format. Unit size started from 001 changed to 003. Page 2- Change Table of Contents to Contents and repagenate. Pages 5-6 Model Numbers were combined from Code 1-23 for AV and AH units. Page 7- AV Codes continued from 24-36.

Continued on the next page.

Daikin Applied, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330

Page 4: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

UV; AH001-008C, UAHX07-20 Des. 3, AV001-006C, UAVX07-15 Des. 3 Rev. R 01/16 RPL 0571158 / Page 4

Parts List Revision History

N 09/13 Page 8- AH Codes continued from 24-36. (Cont.) Page 14- Add coils for AH unit size 008. Pages 9-19- Remove parts that are sheet metal and diagrams. Add AH unit Size 008. Page 20- Field Installed Accessories- Moved filters here. CPL1- Added AH unit size 008. deleted AV units from this page CPL2- Added page for AV units. P 09/13 Numerous changes made. Size 008 added for all AH/UAHX units Title Page - Change model sizes for UAHX and UAVX units. Pages 5-7 Code was split into AH units and Av units. Pages 5-7 Code for AH/UAHX units. Page 8-10 Code for AV/UAVX units. Pages 9-19- Remove parts that are sheet metal and diagrams. Add AH unit Size 008. Pages 16-18 Add Pages for coil section. Page 24- Field Installed Accessories- Moved filters here. CPL1- Added AH unit size 008. Deleted AV units from this page CPL2- Added page for AV units. Q 12/15 Rebrand Daikin format. Add unit size 07 to 001/003; 10 to 004; 13 to 005; 15 to 006; 20 to 008. Page 12- Delete unit size and detail A-A. Page 13- Delete unit size. Page 14- Add unit sizes 010, 013, 015. Change motor 1/4 HP p/n 063353701 to 063353702. Change coupling p/n GCA500015A to GC5021C for 1/4HP motor. Change coupling p/n GCA500015A to GC8116B for 1/3 & 1/2HP motors CPL1, CPL2- Rebrand Daikin format. CPL2- Change motor 1/4 HP p/n 063353701 to 063353702. R 01/16 Page 21- Change 2-way valve 105657816 from 1" to 3/4".

Revision Date Description

Page 5: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

UV; AH001-008C, UAHX07-20 Des. 3, AV001-006C, UAVX07-15 Des. 3 Rev. R 01/16 RPL 0571158 / Page 5

AUB U 08 05 00386Plant Identification

AUB = Auburn

Year of Manufacture08= 200809= 200910= 2010

etc.

U= Unit

Serial Number (build sequence)

Model Number AH, UAHB, UAHF, UAHR, UAHV

Week of Manufacture

UAHB 003 C 01 F HWP 2 WY W Y C Y YY HC3 2M1 A C3 Code 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17

2M7 B LY 1 ST S W 1 2 BT A SFB YY T 1 1 A 1 Y Code 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36

Continued on the next page.

Serial NumberNomenclature

Code 01= Unit TypeAH= Ceiling, Unit VentilatorUAHB= Ceiling, Face & Base, Reheat, Unit VentilatorUAHF= Ceiling, Face & Base, Unit VentilatorUAHR= Ceiling, w/Valve Control, Reheat, Unit VentilatorUAHV= Ceiling, w/Valve Control, Unit Ventilator

Code 02= Unit Size001= Series 1000- 500 CFM (AH only)003= Series 3000- 750 CFM (H07, S07)004= Series 4000- 1000 CFM (H10, S10)005= Series 5000- 1250 CFM (H13, S13)006= Series 6000- 1500 CFM (H15, S15)008= Series 8000- 2000 CFM (H20, S20)

Code 03= Vintage/Design C= Vintage C (example: AH003C)3= Design C (example: UAHV3H07)

Code 04= Unit Voltage01= 230/60/1 27= 460/60/3 03= 208/60/1 29= 230/60/311= 115/60/1 37=575/60/3 12= 208/60/3 47= 265/60/1

Code 05= Damper F= Face & BypassN= None

Code 06= Temperature Controls Provider BRB= Siebe Pneumatic Factory InstalledHWP= Honeywell Pneumatic Factory Installed JCP= Johnson Pneumatic Factory Installed LGP= Landis Gyr/Powers Pneumatic Factory InstalledBCE= Barber-Colman Electric Factory InstalledMN2= MicroTech Network-ASHRAE Cycle IIMN3= MicroTech Network-ASHRAE Cycle IIIMP2= MicroTech Open Protocol-ASHRAE Cycle IIMP3= MicroTech Open Protocol-ASHRAE Cycle IIIMA2= MicroTech Stand-Alone-ASHRAE Cycle IIMA3= MicroTech Stand-Alone-ASHRAE Cycle IIIMM2= MicroTech Stand-Alone Master-ASHRAE Cycle IIMM3= MicroTech Stand-Alone Master-ASHRAE Cycle IIIMS2= MicroTech Stand-Alone Slave-ASHRAE Cycle IIMS3= MicroTech Stand-Alone Slave-ASHRAE Cycle IIIFLE= Controls By Others- Field Installed- ElectricFLP= Controls By Others- Field Installed- Pneumatic

Code 07= MicroTech Occupied/Unoccupied Controls1= Day-Night Changeover Relay, 24V2= Day-Night Changeover Relay, 115V3= Time Clock & Holiday Switch5= NoneY= Controls By Others

Code 08= MicroTech Room Temperature SensorsUY= Unit MountedWY= Wall Mounted w/o TCWT= Wall Mounted w/ TCCY= Wall Mounted w/ Comm Port w/o TCCT= Wall Mounted w/ Comm Port w/ TCYY= Controls By Others

Code 09= MicroTech Tenant OverrideW= Wall Mounted (Part of Wall Sensor) N= NoneY= Controls By Others

Code 10= MT Room Temperature Setpoint Adj. ± 3˚FW= Wall Mounted (Part of Wall Sensor) N= NoneY= Controls By Others

Code 11= MT Ventilation RelayA= Ventilation Lockout- 24VB= Ventilation Lockout- 115VC= Ventilation Interlock, Maximum- 24VD= Ventilation Interlock, Maximum- 115VN= NoneY= Controls By Others

Code 12= Shutdown RelayY= None

Code 13= Always YY

Page 6: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

UV; AH001-008C, UAHX07-20 Des. 3, AV001-006C, UAVX07-15 Des. 3 Rev. R 01/16 RPL 0571158 / Page 6

NomenclatureModel Number- AH, UAHB, UAHF, UAHR, UAHV

Code 14= Heating Coil Type & CapacityHot Water/Chilled Water- 2 PipeHC3= 3-RowHC4= 4-RowHC5= 5-RowHot WaterHW1= 1-RowHW2= 2-RowHW3= 3-RowSteam- Same End DrainSSL= Low Capacity SSH= High CapacityElectric Heat- Open Wire Element1EW= 1 Element 6EW= 6 Element2EW= 2 Element 7EW= 7 Element3EW= 3 Element 8EW= 8 Element4EW= 4 Element 9EW= 9 Element5EW= 5 ElementElectric Heat- Sheathed Element1ES= 1 Element 6ES= 6 Element2ES= 2 Element 7ES= 7 Element3ES= 3 Element 8ES= 8 Element4ES= 4 Element 9ES= 9 Element5ES= 5 ElementNNN= None

Code 15= MicroTech Heating Coil ValveHot Water or Steam, 2-Way Modulating Valve2M1= ½"- #2 Port, 1.3CV2M2= ½"- #3 Port, 2.2CV2M4= ½"- #4 Port, 3.6CV2M5= ¾"- #5 Port, 5.0CV2M6= ¾"- #6 Port, 6.2CVSteam, 2-Way Modulating Valve 2M8= 1"- #7 Port, 8.2CV2M9= 1"- #8 Port, 11.0CVHot Water, 3-Way Modulating Valve 3M2= ½", 2.0CV3M4= ½", 4.0CV3M7= ¾", 6.8CV2EC= 2-Way 2 Pos End of Cycle (1" for ST; ¾" for HW)3EC= 3-Way 2 Pos End of Cycle (¾")NNN= NoneYYY= Controls by Others

Code 16= Hot Water Piping PackageA=Incl. 2-Unions, S&R Pressure Taps, Shutoff ValveB= Incl. 2-Unions, S&R Pressure Taps, 2-Shutoff ValveC= Incl. 2-Unions, S&R Pressure Taps, Shutoff & Flow ValvesY= None

Code 17= Cooling CoilChilled WaterC3= 3-RowC4= 4-RowC5= 5-RowDirect ExpansionAC= Split System Air ConditionerHP= Split System Heat PumpNN= None

Codes 18= Chilled Water Coil Valve2-Way Modulating Valve2M2= ½", 2.0CV2M4= ½", 4.0CV2M7= ¾", 6.8CV3-Way Modulating Valve 3M2= ½", 2.0CV3M4= ½", 4.0CV3M7= ¾", 6.8CV2EC= 2-Way 2 Pos End of Cycle (¾")3EC= 3-Way 2 Pos End of Cycle (¾")NNN= NoneYYY= Controls by Others

Code 19= Chilled Water Piping PackageA= Incl. 2-Unions, S&R Pressure Taps, Shutoff ValveB= Incl. 2-Unions, S&R Pressure Taps, 2-Shutoff ValveC= Incl. 2-Unions, S&R Pressure Taps, Shutoff Valve & Flow ValveY= None

Code 20= Coil Connection LocationsLY= Left Hand, Single CoilRY= Right Hand, Single CoilLR= Left Hand Cooling- Right Hand HeatingRL= Right Hand Cooling- Left Hand Heating LL= Left Hand Cooling- Left Hand HeatingRR= Right Hand Cooling- Right Hand Heating

Code 21= Drain Pan1= Standard2= Stainless Steel

Code 22= Exterior PanelsST= Standard

Code 23= Access PanelsS= StandardU= Unhinged

Code 24= Paint Color of Unit PanelsA= Putty Beige E= Soft GreyB= Soft Blue I= Antique IvoryC= Tile Black P= Prime CoatD= Goldenrod W= Off White

Code 25= External Static Pressure1= 0-.20" 2= .21-.45"(.21-.50" for Unit Size 008)

Code 26= Fan Shaft & Motor Bearing1= Oilable Sleeve2= Permanently Lubricated

Code 27= Air Inlet LocationBT= Bottom Grille, RA, Top Duct Collar OABR= Bottom Grille, RA, Rear Duct Collar OABN= Bottom Grille RA, No OART= Rear Duct Collar RA, Top Duct Collar OARR= Rear Duct Collar RA, Rear Duct Collar OARN= Rear Duct Collar RA, No OA

Continued on the next page.

Page 7: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

UV; AH001-008C, UAHX07-20 Des. 3, AV001-006C, UAVX07-15 Des. 3 Rev. R 01/16 RPL 0571158 / Page 7

Code 28= Outdoor Air DamperA= StandardB= Standard w/Setscrew LockC= Cold Weather InsulatedD= Cold Weather Insulated w/ Setscrew LockR= None, Recirculation Unit

Code 29= Cabinet Mounting & Discharge Air ArrangementSFB= Standard, Front Discharge, Barsock GrilleSFC= Standard, Front Discharge, Duct CollarSFV= Front Barsock Discharge Grille w/Side Defl. VanesPFD= Plenum, Front Discharge, Double Deflection GrillePBD= Plenum, Bottom Discharge, Double Deflection GrillePFC= Plenum, Front Discharge, Duct CollarPFB= Plenum, Front Discharge, Barsock Grille

Code 30= Always YY

Codes 31= Filter TypeP= Permanent MeshM= Renewable Media w/Metal FrameR= Roll FilterT= Throwaway

Code 32= Fiter Indicator1= Dirty Filter LightY= None

Code 33= Return Air Staic Balance1= IncludedY= None

Code 34= Auxiliary Drain PanA= IncludedY= None

Code 35= Service Switch1= IncludedY= None

Code 36= Future Use Only- Always Y

NomenclatureModel Number- AH, UAHB, UAHF, UAHR, UAHV

Page 8: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

UV; AH001-008C, UAHX07-20 Des. 3, AV001-006C, UAVX07-15 Des. 3 Rev. R 01/16 RPL 0571158 / Page 8

UAVV 003 C 01 F HWP 2 WY W U C Y YY HC3 2M1 A C3 Code 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17

2M7 B LY 1 ST S A W D FR A FTD YY P A A A 1 Y Code 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36

Continued on the next page.

Code 01= Unit TypeAV= Floor, Unit Ventilator UAVB= Floor, Face & Base, Reheat, Unit VentilatorUAVR= Floor, w/Valve Control, Reheat, Unit VentilatorUAVS= Floor, Face & Base, Unit VentilatorUAVV= Floor, w/Valve Control, Unit Ventilator

Code 02= Unit Size001= Series 1000- 500 CFM (AV only)003= Series 3000- 750 CFM (H07, S07)004= Series 4000- 1000 CFM (H10, S10)005= Series 5000- 1250 CFM (H13, S13)006= Series 6000- 1500 CFM (H15, S15)

Code 03= Vintage/Design C= Vintage C (example: AV003C)3= Design C (example: UAVV3H07)

Code 04= Unit Voltage01= 230/60/1 27= 460/60/3 03= 208/60/1 29= 230/60/311= 115/60/1 37=575/60/3 12= 208/60/3 47= 265/60/1

Code 05= Damper F= Face & Bypass N= None

Code 06= Temperature Controls Provider BRB= Siebe Pneumatic Factory InstalledHWP= Honeywell Pneumatic Factory Installed JCP= Johnson Pneumatic Factory Installed LGP= Landis Gyr/Powers Pneumatic Factory InstalledBCE= Barber-Colman Electric Factory InstalledMN2= MicroTech Network-ASHRAE Cycle IIMN3= MicroTech Network-ASHRAE Cycle IIIMP2= MicroTech Open Protocol-ASHRAE Cycle IIMP3= MicroTech Open Protocol-ASHRAE Cycle IIIMA2= MicroTech Stand-Alone-ASHRAE Cycle IIMA3= MicroTech Stand-Alone-ASHRAE Cycle IIIMM2= MicroTech Stand-Alone Master-ASHRAE Cycle IIMM3= MicroTech Stand-Alone Master-ASHRAE Cycle IIIMS2= MicroTech Stand-Alone Slave-ASHRAE Cycle IIMS3= MicroTech Stand-Alone Slave-ASHRAE Cycle IIIFLE= Controls By Others- Field Installed- ElectricFLP= Controls By Others- Field Installed- Pneumatic

Code 07= MicroTech Occupied/Unoccupied Controls1= Day-Night Changeover Relay, 24V2= Day-Night Changeover Relay, 115V3= Time Clock & Holiday Switch5= NoneY= Controls By Others

Code 08= MicroTech Room Temperature SensorsUY= Unit MountedWY= Wall Mounted w/o TCWT= Wall Mounted w/ TCCY= Wall Mounted w/ Comm Port w/o TCCT= Wall Mounted w/ Comm Port w/ TCYY= Controls By Others

Code 09= MicroTech Tenant OverrideU= Unit MountedW= Wall Mounted (Part of Wall Sensor) N= NoneY= Controls By Others

Code 10= MT Room Temperature Setpoint Adj. ± 3˚FU= Unit MountedW= Wall Mounted (Part of Wall Sensor) N= NoneY= Controls By Others

Code 11= MT Ventilation RelayA= Ventilation Lockout- 24VB= Ventilation Lockout- 115VC= Ventilation Interlock, Maximum- 24VD= Ventilation Interlock, Maximum- 115VN= NoneY= Controls By Others

Code 12= Shutdown RelayY= None

Code 13= Always YY

Code 14= Heating Coil Type & CapacityHot Water/Chilled Water- 2 PipeHC3= 3-RowHC4= 4-RowHC5= 5-RowHot WaterHW1= 1-RowHW2= 2-RowHW3= 3-RowSteam- Same End DrainSSL= Low Capacity SSH= High CapacitySteam- Opposite End DrainSDL= Low CapacitySDH= High CapacityElectric Heat- Open Wire Element1EW= 1 Element 6EW= 6 Element2EW= 2 Element 7EW= 7 Element3EW= 3 Element 8EW= 8 Element4EW= 4 Element 9EW= 9 Element5EW= 5 ElementElectric Heat- Sheathed Element1ES= 1 Element 6ES= 6 Element2ES= 2 Element 7ES= 7 Element3ES= 3 Element 8ES= 8 Element4ES= 4 Element 9ES= 9 Element5ES= 5 ElementNNN= None

Model Number- AV, UAVB, UAVR, UAVS, UAVVNomenclature

Page 9: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

UV; AH001-008C, UAHX07-20 Des. 3, AV001-006C, UAVX07-15 Des. 3 Rev. R 01/16 RPL 0571158 / Page 9

Model Number- AV, UAVB, UAVR, UAVS, UAVVNomenclature

Code 22= Exterior PanelsST= Standard

Code 23= Access PanelsS= StandardK= Key Lock

Code 24= Paint Color of Unit PanelsA= Putty Beige E= Soft GreyB= Soft Blue I= Antique IvoryC= Tile Black P= Prime CoatD= Goldenrod W= Off White

Code 25= Paint Color of TopA= Putty Beige H= Textured Charcoal BronzeB= Soft Blue I= Antique IvoryC= Tile Black P= Prime CoatD= Goldenrod W= Off WhiteE= Soft Grey

Code 26= Unit Depth/Adapter BackA= 16-5/8" Open Pipe PassageB= 16-5/8" Closed Pipe TunnelC= 16-5/8" w/ 9" Vertical Finished BackD= 21-7/8" Adapter Back Pipe PassageE= 21-7/8" Full Adapter Back Closed Pipe TunnelF= 21-7/8" Open Adapter BackK= 28" Total, Using 11-3/8" Top ExtensionL= 28" Total Closed Pipe Tunnel Full Adapter BackM= 21-7/8" Energy Recovery System Adapter Back

Code 27= Air Inlet LocationFR= Front RA, Rear OAFB= Front RA, Bottom Duct Collar OAFN= Front RA, No OAFT= Front RA, Top Duct Collar OADR= Draft Stop RA, Rear OADB= Draft Stop RA, Bottom Duct Collar OADN= Draft Stop RA, No OADT= Draft Stop RA, Top Duct Collar OA

Code 28= Outdoor Air DamperA= StandardB= Standard w/Setscrew LockC= Cold Weather InsulatedD= Cold Weather Insulated w/ Setscrew LockR= None, Recirculation Unit

Code 29= Cabinet Mounting & Discharge Air ArrangementWall MountedWFD= w/Plenum Front Discharge, Double Deflection GrilleWTB= Top Discharge, Barsock GrilleFloor MountedFTB= Top Discharge, Barsock Grille w/RH Top Access DoorFDC= Top Duct Collar w/RH Top Access DoorFTV= Top Grille, Side Deflection Vanes w/RH Top Access DoorFTD= Top Barsock Grille w/RH & LH Top Access DoorsFVD= Top Grille, Side Deflection Vanes w/LH Top Access DoorFDD= Top Duct Collar w/RH & LH Top Access DoorsInverted Wall MountedMFD= w/Plenum Front Discharge, Double Deflection GrilleMBB= Bottom Discharge, Bar Stock Grille

Code 30= Always YY

Code 15= MicroTech Heating Coil ValveHot Water or Steam, 2-Way Modulating Valve2M1= ½"- #2 Port, 1.3CV2M2= ½"- #3 Port, 2.2CV2M4= ½"- #4 Port, 3.6CV2M5= ¾"- #5 Port, 5.0CV2M6= ¾"- #6 Port, 6.2CVSteam, 2-Way Modulating Valve 2M8= 1"- #7 Port, 8.2CV2M9= 1"- #8 Port, 11.0CVHot Water, 3-Way Modulating Valve 3M2= ½", 2.0CV3M4= ½", 4.0CV3M7= ¾", 6.8CV2EC= 2-Way 2 Pos End of Cycle (1" for ST; ¾" for HW)3EC= 3-Way 2 Pos End of Cycle (¾")NNN= NoneYYY= Controls by Others

Code 16= Hot Water Piping PackageA=Incl. 2-Unions, S&R Pressure Taps, Shutoff ValveB= Incl. 2-Unions, S&R Pressure Taps, 2-Shutoff ValveC= Incl. 2-Unions, S&R Pressure Taps, Shutoff & Flow ValvesY= None

Code 17= Cooling CoilChilled WaterC3= 3-RowC4= 4-RowC5= 5-RowDirect ExpansionAC= Split System Air ConditionerHP= Split System Heat PumpNN= None

Codes 18= Chilled Water Coil Valve2-Way Modulating Valve2M2= ½", 2.0CV2M4= ½", 4.0CV2M7= ¾", 6.8CV3-Way Modulating Valve 3M2= ½", 2.0CV3M4= ½", 4.0CV3M7= ¾", 6.8CV2EC= 2-Way 2 Pos End of Cycle (¾")3EC= 3-Way 2 Pos End of Cycle (¾")NNN= NoneYYY= Controls by Others

Code 19= Chilled Water Piping PackageA= Incl. 2-Unions, S&R Pressure Taps, Shutoff ValveB= Incl. 2-Unions, S&R Pressure Taps, 2-Shutoff ValveC= Incl. 2-Unions, S&R Pressure Taps, Shutoff & Flow ValvesY= None

Code 20= Coil Connection LocationsLY= Left Hand, Single CoilRY= Right Hand, Single CoilLR= Left Hand Cooling- Right Hand HeatingRL= Right Hand Cooling- Left Hand Heating LL= Left Hand Cooling- Left Hand HeatingRR= Right Hand Cooling- Right Hand Heating

Code 21= Drain Pan1= Standard2= Stainless Steel

Page 10: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

UV; AH001-008C, UAHX07-20 Des. 3, AV001-006C, UAVX07-15 Des. 3 Rev. R 01/16 RPL 0571158 / Page 10

Model Number- AV, UAVB, UAVR, UAVS, UAVVNomenclature

Codes 31= Filter TypeP= Permanent MeshM= Renewable Media w/Metal FrameT= Throwaway

Code 32= Thru Piping in Upper Pipe TunnelA= (2) 7/8" Uninsulated Straight PipeB= (1) 1-5/8" Insulated Pipe- SupplyC= (1) 1-5/8" Insulated Pipe- ReturnD= (2) 1-5/8" Insulated PipeE= (1) 2-1/8" Insulated Pipe- SupplyF= (1) 2-1/8" Insulated Pipe- ReturnG= (2) 2-1/8" Insulated PipeH= (1) 1-5/8" Supply & (1) 2-1/8" Return InsulatedJ= (1) 2-1/8" Supply & (1) 1-5/8" Return InsulatedY= None

Code 33= Thru Piping in Lower Pipe TunnelA= (1) 1-5/8" Insulated- SupplyB= (1) 1-5/8" Insulated- ReturnC= (2) 2-1/8" UninsulatedY= None

Code 34= Auxiliary Drain PanA= IncludedY= None

Code 35= Service Switch1= IncludedY= None

Code 36= Always Y

Page 11: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

UV; AH001-008C, UAHX07-20 Des. 3, AV001-006C, UAVX07-15 Des. 3 Rev. R 01/16 RPL 0571158 / Page 11

Part Part Description Number 16.625” Closed Tunnel 063290103 16.625” Finished Back 063290391 21.875” Top Only 105657001 21.875” Full Open Tunnel 063291091 21.875” Full Closed Tunnel 063292491 21.875”, 2” Step Down, Full Open 107780091 21.875”, 2” Step Down, Full Closed 107792191 28” Full Closed Tunnel 107639491 28" Top Only 106001591

Unit Size 001 - 003/07 3 Fan Units

Part Part Description Number 16.625” Closed Tunnel 063290104 16.625” Finished Back 063290491 21.875” Top Only 105657002 21.875” Full Open Tunnel 063291191 21.875” Full Closed Tunnel 063292591 21.875”, 2” Step Down, Full Open 107780191 21.875”, 2” Step Down, Full Closed 107792291 28” Full Closed Tunnel 107639591 28" Top Only 106001691

Unit Size 004/10 4 Fan Units

Part Part Description Number 16.625” Closed Tunnel 063290105 16.625” Finished Back 063290591 21.875” Top Only 105657003 21.875” Full Open Tunnel 063291291 21.875” Full Closed Tunnel 063292691 21.875”, 2” Step Down, Full Open 107780291 21.875”, 2” Step Down, Full Closed 107792391 28” Full Closed Tunnel 107639691 28" Top Only 106001791

Part Part Description Number 16.625” Closed Tunnel 063290106 16.625” Finished Back 063290691 21.875” Top Only 105657004 21.875” Full Open Tunnel 063291391 21.875” Full Closed Tunnel 063292791 21.875”, 2” Step Down, Full Open 107780391 21.875”, 2” Step Down, Full Closed 107792491 28” Full Closed Tunnel 107639791 28" Top Only 106001891

Adapter Back Kits

Unit Size 005/13 5 Fan Units

Unit Size 006/15 6 Fan Units

Page 12: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

UV; AH001-008C, UAHX07-20 Des. 3, AV001-006C, UAVX07-15 Des. 3 Rev. R 01/16 RPL 0571158 / Page 12

1

24.80"

1

2

12"

12"

"L"

External CabinetryAV Cabinet

See Cabinet/Chassis components

Ref Description Part Number Qty. No. 1 Front Panel, End 1 2

2 Front Panel, Center 1 1 N/S Cabinet/Chassis components 1

1 Contact Daikin with unit model and serial number for part numbers on cabinet/chassis components.

Page 13: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

UV; AH001-008C, UAHX07-20 Des. 3, AV001-006C, UAVX07-15 Des. 3 Rev. R 01/16 RPL 0571158 / Page 13

External CabinetryAH Cabinet

1112

FRONT PANEL

Ref Description Part Number Qty. 11 Bottom Rear Access Panel 1 1

12 Bottom Front Access Panel 1 1 N/S Rear Panel 1 1

1 Contact Daikin with unit model and serial number for part numbers on cabinet/chassis components.

Page 14: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

UV; AH001-008C, UAHX07-20 Des. 3, AV001-006C, UAVX07-15 Des. 3 Rev. R 01/16 RPL 0571158 / Page 14

Ref. Description Part Unit Size/Qty. No. Number 001/003/07 004/10 005/13 006/15 008/20 N/S Shaft GC8504 1 N/S Shaft GC8505 1 N/S Shaft GC8506 1 N/S Shaft GC10116 1 1 N/S Wheel, Plastic 063262901 2 3 4 5 N/S Wheel, Metal GF110 4 N/S Sleeve Bearing AV units 4ACE2556A 1 1 1 1 N/S Ball Bearing AH units 4AAE7976 1 1 1 1 1 N/S Coupling, 1/4 HP Motor GC5021C 1 1 1 1 1 N/S Coupling 1/3 HP & 1/2 HP Motor GC8116B 1 1 1 1 1 N/S Housing AV units 106099201 2 3 4 5 N/S Housing AH units GCF5321 4 N/S Gasket AV units 105622201 1 1 1 1 1 N/S Motor- AV Unit 1

1/4 HP, Sleeve Bearing until 4/02 063261701 1 1 1 1 1 1/4 HP, Sleeve Bearing 4/02 & later 063261702 1 1 1 1 1 N/S Motor- AH Unit 1

1/4 HP, Ball Bearing 063353701 1 1 1 1 1 1/3 HP, Ball Bearing 107654201 1 1 1 1 1 1/2 HP, Ball Bearing LADQ5949 1 1 1 1 1

Fan Section Motor and Fan Unit Sizes 001 - 008

Components

N/S = Not shown on diagram.1 Motors are 115/60/1 regardless of unit voltage. It is important that the correct X1 transformer be installed (see Code 5 for voltage).NOTE: Do not mix plastic & aluminum wheels on same unit.

Page 15: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

UV; AH001-008C, UAHX07-20 Des. 3, AV001-006C, UAVX07-15 Des. 3 Rev. R 01/16 RPL 0571158 / Page 15

Description 001/003/07 004/10 005/13 006/15 008/20 3 Fan 4 Fan 5 Fan 6 Fan 4 Fan 500/750 CFM 1000 CFM 1250 CFM 1500 CFM 2000 CFM ELECTRIC HEAT ELEMENT (HTR 1/9) Open Wire Element, 208V 063413601 063413602 063413603 063413604 063413604 Element, 230V 063413605 063413606 063413607 063413608 063413608 Element, 265V 063413701 063413702 063413703 063413704 063413704 Element, 460V 063413609 063413610 063413611 063413612 063413612 Element, 575V 063413613 063413614 063413615 063413616 063413616 Sheathed Element, 208V 4EHH8887 4EHH8888 4EHH8889 4EHH8890 N/A Element, 230V 4EHH8891 4EHH8892 4EHH8893 4EHH8894 N/A Element, 265V 063414501 063414502 063414503 063414504 N/A Element, 460V 4EHH8895 4EHH8896 4EHH8897 4EHH8898 N/A Element, 575V 4EHH8899 4EHH8900 4EHH8901 4EHH8902 N/A

Part Number/Unit Size

Electric Heat

Sch. Description Part Unit Size Sym. Number 001/003/07 004/10 005/13 006/15 008/20 F2A/F6C Fuse, 30A 208/230/265V 4EHG1979 2-6 2-6 2-6 2-6 2-6 F2A/F6C Fuse, 60A 208/230/265V 4EHG4083 2-6 2-6 2-6 2-6 2-6

AF Airflow Switch 4EMB8125 1 1 1 1 1 DF Deadfront Switch 4EAL2427 1 1 1 1 1 OH1 Thermostat, Overheat AV/AH 4ELN7697 1 1 1 1 1 OH2 Thermostat, Overheat AH 4ELN5523 1 1 1 1 1

Electric Controls

Electric Heat Elements

Page 16: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

UV; AH001-008C, UAHX07-20 Des. 3, AV001-006C, UAVX07-15 Des. 3 Rev. R 01/16 RPL 0571158 / Page 16

Coils Section

Hot Water Hot Water, Low Capacity, 1-row N/A 107691901 056953742 056953743 056953744 Hot Water, Med. Capacity, 2-row N/A 056953701 056953702 056953703 056953704 Chilled Water / Hot Water* Chilled Water, 3-row N/A 056953711 056953712 056953713 056953714 Chilled Water, 4-row N/A 056953721 056953723 056953725 056953727 Chilled Water, 5-row N/A 056953731 056953732 056953733 056953734 Steam** Steam,Low Capacity, 1-row N/A GRF1013 GRF1014 GRF1015 GRF1016 Steam, High Capacity, 2-row N/A GRF1000 GRF1001 GRF1002 GRF1003 Check Valve N/A 037520002 037520002 037520002 037520002 Direct Expansion Direct Expansion Coil 057055801 056666702 056666701 056666601 056666602 Direct Expansion Coil, Heat Pump N/A 056666702 056666701 056666601 056666602 Expansion Valve Expansion Valve 4FDV8931 056662904 056662904 056662902 056662905 Check Valve (heat pump coil) N/A 037520002 037520002 037520002 037520002

Part Number

72" Long

006/008/15/206 Fan

1500/2000 CFM

60" Long

005/135 Fan

1250 CFM

004/104 Fan

1000 CFM

48" Long

003/07 3 Fan

750 CFM36" Long

001 3 Fan

500 CFM36" Long

Description

N/A = Not Applicable* Reference Instructions - Hot Water Coil Mounting p/n 057053201.** Reference Instructions - Cold Water Coil Mounting p/n 057053101.

Coil Support ChannelPart Number 56958701

ScrewPart Number 4SBA4206

Channel Mount Diagram

Page 17: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

UV; AH001-008C, UAHX07-20 Des. 3, AV001-006C, UAVX07-15 Des. 3 Rev. R 01/16 RPL 0571158 / Page 17

AV/AH Coil SectionCoil Mount, Chilled Water Diagram

(Ref. 57053101)

AIR FLOW

See Note 5

LEFT-HAND APPLICATION RIGHT-HAND APPLICATION

30

20

DETAIL "A"

21

1921

See Note 4

Plug from Coil Ref. Note 1

AIR FLOW

NOTES:1. Remove upper plug Item 30 from coil and install in Item 2 as shown in Detail "A".2. Return label is placed always opposite drain connections. Supply label is placed always at center connection.3. Braze Item 1 with drain at bottom of connection.4. Drain connection floor unit or wall unit.5. Drain connection ceiling.6. Chilled water coil located on leaving air side (position 2) when used with hot water, steam or electric heat.7. Chilled water coil located on entering air side (position 1) when single coil.

See Note 4

See Note 6See Note 5

See Note 6

See Note 7

See Note 7

Page 18: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

UV; AH001-008C, UAHX07-20 Des. 3, AV001-006C, UAVX07-15 Des. 3 Rev. R 01/16 RPL 0571158 / Page 18

AV/AH Coil SectionCoil Mount, Hot Water Diagram

(Ref. 57053201)

AIR FLOW

LEFT-HAND APPLICATION RIGHT-HAND APPLICATION

30

20

Plug from Coil Ref. Note 1

DETAIL "A"

21

1921

See Note 5

See Note 4

NOTES:1. Remove upper plug Item 30 from coil and install in Item 2 as shown in Detail "A".2. Return label is placed always opposite drain connections. Supply label is placed always at center connection.3. Braze Item 1 with drain at bottom of connection.4. Drain connection floor unit or wall unit.5. Drain connection ceiling.6. Hot water coil located on leaving air side (position 2) when used with direct expansion coil.7. Hot water coil located on entering air side (position 1) when single coil or with chilled water coil.

See Note 4

See Note 6See Note 5

See Note 7

See Note 6

See Note 7

Page 19: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

UV; AH001-008C, UAHX07-20 Des. 3, AV001-006C, UAVX07-15 Des. 3 Rev. R 01/16 RPL 0571158 / Page 19

Ref. Description Part Unit Size No. Number 001/003/07 004/10 005/13 006/15 008/20 N/S Drain Pan AV GCF5014 1 N/S Drain Pan AV GCF5015 1 N/S Drain Pan AV GCF5016 1 N/S Drain Pan AV GCF5017 1 N/S Drain Pan, 1-Coil AH GCF5225 1 N/S Drain Pan, 1-Coil AH GCF5226 1 N/S Drain Pan, 1-Coil AH GCF5227 1 N/S Drain Pan, 1-Coil AH GCF5228 1 1 N/S Drain Pan, 2-Coil AH GCF5019 1 N/S Drain Pan, 2-Coil AH GCF5020 1 N/S Drain Pan, 2-Coil AH GCF5021 1 N/S Drain Pan Kit, 2-Coil AH 105672501 1 1 N/S Auxillary Drain Pan (C29 = FTB only) 105677701 1 1 1 1 1 N/S Auxillary Drain Pan (C29 = SFB only) 105677801 1 1 1 1 1 N/S Drain Plug 4RHD8916 1 1 1 1 1

N/S Shaft, Damper GC10747 1 1 1 1 1 N/S Counterweight GC10744 2 1 N/S Counterweight GC10745 1 1 2 2 N/S Crankarm GCF5203 1 2 2 2 2

Damper SectionDrain Pan, and Face & Bypass Damper Components

N/S = Not shown on diagram.

Page 20: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

UV; AH001-008C, UAHX07-20 Des. 3, AV001-006C, UAVX07-15 Des. 3 Rev. R 01/16 RPL 0571158 / Page 20

Ref. Description Part Unit Size No. Number 001/003/07 004/10 005/13 006/15 008/20 N/S Damper, OA 500/750 CFM 106010301 1 N/S Damper, OA 1000 CFM 106010401 1 N/S Damper, OA 1250 CFM 106010501 1 N/S Damper, OA 1500 CFM 106010601 1 1 N/S Damper, Room Air 500/750 CFM 106095801 1 N/S Damper, Room Air 1000 CFM 106095901 1 N/S Damper, Room Air 1250 CFM 106096001 1 N/S Damper, Room Air 1500 CFM 106096101 1 1

N/S Bearing, Sleeve 4ACN1491 5 5 5 5 5 N/S Spring, Damper 057086601 1 1 1 1 1 N/S Crankarm GCF5474 1 1 1 1 1 N/S Crank GCF5000 1 1 1 1 1 N/S OA Shaft Assy 106452801 1 1 1 1 1

N/S Shaft 1 until 2/99 GC11634 1 1 1 1 1 N/S Shaft 2/99 & later 105621801 1 1 1 1 1 N/S Shaft 1 until 2/99 GC10024 1 1 1 1 1 N/S Shaft 2/99 to 3/04 105621601 1 1 1 1 1 N/S Right Side Actuator Assy 1 2/99 & later 105622002 1 1 1 1 1

N/S Gasket BJ0270100 5 Ft. 6 Ft. 7 Ft. 8 Ft. 8 Ft. N/S Mohair BY0010100 13 Ft. 17 Ft. 21 Ft. 25 Ft. 25 Ft.

Damper SectionOA & Room Air Damper Components

N/S = Not shown on diagram.1 Replaces counterweight - RA (GC121A), angle, and screw.2 In February 1999, a second "slave" actuator was added to the right side of the room air damper. The new shafts are only used when this additional actuator is present.

Page 21: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

UV; AH001-008C, UAHX07-20 Des. 3, AV001-006C, UAVX07-15 Des. 3 Rev. R 01/16 RPL 0571158 / Page 21

Ref. Description Part Unit Size No. Number 001/003/07 004/10 005/13 006/15 008/20 N/S 3-Way Valve 1/2" Connections, #2 Port, 2.2 CV 105600201 1 1 1 1 1 1/2" Connections, #4 Port, 4.4 CV 105600202 1 1 1 1 1 3/4" Connections, #6 Port, 7.5 CV 105600203 1 1 1 1 1

N/S 2-Way Valve 1/2" Connections, #2 Port, 1.3 CV 105600301 1 1 1 1 1 1/2" Connections, #3 Port, 2.2 CV 105600302 1 1 1 1 1 1/2" Connections, #4 Port, 4.4 CV 105600303 1 1 1 1 1 3/4" Connections, #5 Port, 5.5 CV 105600304 1 1 1 1 1 3/4" Connections, #6 Port, 7.5 CV 105600305 1 1 1 1 1 1" Connections, #7 Port, 10.0 CV 105600306 1 1 1 1 1 1" Connections, #8 Port, 14.0 CV 105600307 1 1 1 1 1

N/S End Of Cycle Valve Kits- 2 Way Valves 3/4" Connections, Straight, 8.0 CV 105657816 1 1 1 1 1 3/4" Conn., Normally Closed, 7.0 CV 105657817 1 1 1 1 1 1" Conn., Normally Open, 7.0 CV 105657814 1 1 1 1 1

N/S End Of Cycle Valve Kits- 3 Way Valves 3/4" Conn, NO/NC, 7.0 CV 105657815 1 1 1 1 1

N/S Actuator Actuator, OA 105600401 1 1 1 1 1 Actuator, FBP 105600401 1 1 1 1 1 Actuator, Water & Steam 056610701 1 1 1 1 1

Hydronic Valves and Actuators

N/S = Not shown on diagram.

Page 22: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

UV; AH001-008C, UAHX07-20 Des. 3, AV001-006C, UAVX07-15 Des. 3 Rev. R 01/16 RPL 0571158 / Page 22

Controls Ref. Sch. Description Part Unit Size No. Sym. Number 001 003 004 005 006 008 07 10 13 15 20 N/S --- PC Board Control MicroTech M325 107627201 1 1 1 1 1 1

N/S Sensor- Humidity Transducer 106048601 1 1 1 1 1 1 N/S S1 Sensor- Room Temp Unit Mtd. GEF1947 1 1 1 1 1 1 N/S S1 Sensor- Room Temp Wall Mtd. 1

N/S S2 Sensor, Discharge Air Temp GEF1947 1 1 1 1 1 1 N/S S3 Sensor, Outdoor Air 80" GEF1948 1 1 1 1 1 1 N/S S4 Sensor, Mixed Air Temp 3 Fan 063297203 1 1 Sensor, Mixed Air Temp 4 Fan 063297204 1 Sensor, Mixed Air Temp 5 Fan 063297205 1 Sensor, Mixed Air Temp 6 Fan 063297206 1 1 N/S S5 Sensor, Water Temp GEF1948 1 1 1 1 1 1

N/S T4 Thermostat, Low Temp DE Coil 4ELN7604 1 1 1 1 1 1 N/S T6 TStat, Low Temp 144" Cap Tube 4ELN9178 1 1 1 1 1 1 N/S X1 Transformer- Motor Speed 1/4 HP Motor 120V Primary 105658001 1 1 1 1 1 1 1/4 HP Motor 208/265V Primary 063338302 1 1 1 1 1 1 1/3 or 1/2 HP Motor 115/460/575V 4EPB8039 1 1 1 1 1 1 1/3 or 1/2 HP Motor 208/230/265-277V 4EPB8040 1 1 1 1 1 1 N/S X2 Transformer- DE Cool 40 VA 115/460/575V 060630802 1 1 1 1 1 1 40 VA 208/230V/24V 060630802 1 1 1 1 1 1 40 VA 277/24V 060630802 1 1 1 1 1 1 N/S X3 Transformer- Control 75 VA 120V-24V Sec 062986902 1 1 1 1 1 1 75 VA 208/240-24V 056717701 1 1 1 1 1 1 75 VA 265-277/460-24V 4EPC9177 1 1 1 1 1 1 N/S X4 Transformer- Step Down 500 VA 460/240V 4EPC6552A 1 1 1 1 1 1 750 VA 460V 4EPC7743 1 1 1 1 1 1 N/S X5 Transformer 40VA 208/240-24V 063042401 1 1 1 1 1 1 50VA 277-24V 060630702 1 1 1 1 1 1 40VA 120-24V 060630802 1 1 1 1 1 1 N/S X6 Transformer, UVC 4EPC9188 1 1 1 1 1 1

N/S --- PC Board Controls Controls By Others T4 Thermostat, Control- DE DE Enter @28°F 4ELN7604 1 1 1 1 1 1 REC Receptacle, 15Amp, Dual Voltage until 4/04 4EGA4209 1 1 1 1 1 1 RC3 Receptacle, DE- 20Amp until 4/04 4EGA4307 1 1 1 1 1 1 Plug, Shorting until 4/04 4EFA9248 1 1 1 1 1 1 Plug 4EFA8173 1 1 1 1 1 1 TDR2 Time Delay Relay Anti-Short, 5 min. 4EWS7798 1 1 1 1 1 1 Cord-Set 10Amp, 115V, 107" 067183501 1 1 1 1 1 1 N/S = Not shown on diagram.1 Contact local Parts Distributor. Unit model and serial number is required for proper identification.

Page 23: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

UV; AH001-008C, UAHX07-20 Des. 3, AV001-006C, UAVX07-15 Des. 3 Rev. R 01/16 RPL 0571158 / Page 23

Controls

N/S X7 Fuseholder 4EHB1933 N/S FC/FD Fuse, X4 Transformer, 4.0 amp 4EHG7663 N/S FC/FD Fuse, X4 Transformer, 3.5 amp 4EHG7713 N/S FA Fuse, 10.0 amp 4EHG7795 N/S FA Fuse, 9.0 amp 4EHG8684 N/S FA Fuse, 7.0 amp 4EHG7750 N/S FA Fuse, 6.25 amp 4EHG8910 N/S FA Fuse, 5.6 amp 4EHG7749 N/S FA Fuse, 5.0 amp 4EHG8089 N/S FA Fuse, 4.5 amp 4EHG7664 N/S FA Fuse, 4.0 amp 4EHG7663 N/S FA Fuse, 3.5 amp 4EHG7713 N/S FA Fuse, 3.0 amp 4EHG7748 N/S --- Cord Set, Motor Plug, 24" 4EFZ7630 N/S --- Cord Set, Motor Receptacle, 6" 4EGZ7629 N/S --- Receptacle, Dual Volt 1 4EGA4209 N/S --- Receptacle, DE Cool 4EGA4307

N/S R4 Fan Relay until 6/99 4EWJ8505 Fan Relay * 6/99 & later 4EWJ9054 N/S R5 Night Setback Relay 24V 4EWJ9054 Night Setback Relay 115V 4EWJ9053 N/S R6 Vent Lockout Relay 24V 4EWJ9054 Vent Lockout Relay 115V 4EWJ9053 N/S R8 RVSG Valve Relay, DE Cooling 4EWJ8799 N/S C1/C11 Elec. Ht. Relay Operating & Backup 4EWJ8799 N/S R13 Interlock Exhaust Fan Relay 24V 4EWJ9054 Interlock Exhaust Fan Relay 115V 4EWJ9053 N/S TDR Time Delay Relay, Low Volt. Prot. Electric Heat 4EWS7798

N/S SW1 Switch, Disconnect, Electric Heat, 100 amp 4EUL6509A Switch, Disconnect, Electric Heat, 225 amp 4EVQ6319 N/S SW1 Switch, Disconnect, Non-Electric Heat 106616101 N/S SW2 Switch, Fan Speed, Remote GE420A N/S SW2 Rotary Switch, 2-Pole (120V, 227V) 057543001 N/S SW2 Rotary Switch, 3-Pole (208V, 230V) 057542901 N/S --- Knob (Rotary Switch) 802018013 N/S SW3 Switch, Day-Night/TOR 4EAL7261 N/S SW4 Switch, Holiday 4EAL7260 N/S SW5 Switch, Emergency, Elec. Heat, Heat Pump 4EAL7261 N/S SW6 Switch, Energy Conserving, Heat Pump 4EAL7759 N/S TC 24 hour Time Clock with Reserve Power, 120V 4ETA9083 N/S TC 24 hour Time Clock with Reserve Power, 208-230V 4ETA9094 N/S Ref. Time Clock Instruction with Reserve Power GE1424

Bub.No.

Ref.No. Description Part

Number

Fuses, Relays, Switches and Time Clock

N/S = Not shown on diagram.* If 4EWJ9054 is installed on units built prior to June 15, 1999, the R4 harness terminals must be field retrofitted with 1/4" terminals.1 Dual voltage receptacle was removed from std control box, per PC 9754, effective 10-16-89. (Used in "Controls By Others" application.)

Page 24: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

UV; AH001-008C, UAHX07-20 Des. 3, AV001-006C, UAVX07-15 Des. 3 Rev. R 01/16 RPL 0571158 / Page 24

Ref. Description Part Unit Size No. Number 001/003/07 004/10 005/13 006/015 008/20 N/S Filter, Air- Permanent Aluminum GO1006 1 Box of 25 GO1006 105637401 N/S Filter, Air- Permanent Aluminum GO1007 1 Box of 25 GO1007 105637501 N/S Filter, Air- Permanent Aluminum GO1008 1 Box of 25 GO1008 105637601 N/S Filter, Air- Permanent Aluminum GO1006 2 2 Box of 25 GO1006 105637401

N/S Filter, Air- Throwaway GO279C 1 Box of 12 GO279C 105637801 N/S Filter, Air- Throwaway GO280C 1 Box of 12 GO280C 105637901 N/S Filter, Air- Throwaway GO281C 1 Box of 12 GO281C 105638001 N/S Filter, Air- Throwaway GO279C 2 2 Box of 12 GO279C 105637801

N/S Renewable Filter Rack & Media GOF501 1 Box of 25 GOF501 105637001 N/S Renewable Filter Rack & Media GOF502 1 Box of 25 GOF502 105637101 N/S Renewable Filter Rack & Media GOF503 1 Box of 25 GOF503 105637201 N/S Renewable Filter Rack & Media GOF501 2 2 Box of 25 GOF501 105637001

N/S Renewable Media KJ0100400 1 1 1 1 1

Field Installed Accessories

Filters

N/S = Not shown on diagram.

Page 25: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs.To Locate A Distributor, Go To www.DaikinApplied.com or Call 1-800-37PARTS

Critical Daikin Applied OEM PartsAre What Your HVAC Unit Needs!

571158 Rev. R 01/2016 CPL Page 1 of 2

AAF Unit VentilatorsHerman Nelson Unit Ventilators

AH 001 - 008, Vintage C

UAHB, UAHF, UAHR, UAHV07 - 20 Design 3

Critical Components Unit Sizes Voltage Part Number

Control MicroTech M325 Controller ALL ALL 107627201

Blower Fan MotorMotor, Ball Bearing, 1/4HP 001 - 008 (07-20) 115/60/1 063353701Motor, Ball Bearing, 1/3 HP 001 - 008 (07-20) 115/60/1 107654201Motor, Ball Bearing, 1/2 HP 001 - 008 (07-20) 115/60/1 LADQ5949

Blower Fan Assembly Fan Housing 001 - 006 (07-15) N/A 106099201Fan Housing 008 (20) N/A GCF5321Fan Wheel, Metal 001 - 006 (07-15) N/A 063257601Fan Wheel, Plastic 001 - 006 (07-15) N/A 063262901Fan Wheel, Plastic 008 (20) N/A GF110

Page 26: Classmate Conventional Unit Ventilators - Daikin Appliedsalesportal.daikinapplied.com/bizlit/DocumentStorage/Unit... · AAF Herman Nelson Classmate Conventional Unit Ventilators AH

Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs.To Locate A Distributor, Go To www.DaikinApplied.com or Call 1-800-37PARTS

Critical Daikin Applied OEM PartsAre What Your HVAC Unit Needs!

571158 Rev. R 01/2016 CPL Page 2 of 2

AAF Unit VentilatorsHerman Nelson Unit Ventilators

AV 001 - 006, Vintage C

UAVB, UAVR, UAVS, UAVV07 - 15 Design 3

Critical Components Unit Sizes Voltage Part Number

Control MicroTech M325 Controller ALL ALL 107627201

Blower Fan MotorMotor, Sleeve Bearing, 1/4HP 001 - 006 (07 - 15) 115/60/1 063261702

Blower Fan Assembly Fan Housing ALL N/A 106099201Fan Wheel ALL N/A 063262901