Page 1: Classic Magstripe Remote Controller (Old-LCU1)

06.06.03 1 of 17

VingCard 6866 Remote Controller

Measurements

and Installation

Page 2: Classic Magstripe Remote Controller (Old-LCU1)

06.06.03 2 of 17

Introduction. This manual describes: • Dimension for parts • Installation alternatives for Remote Controller. • System power requirements. • Connection alternatives for units to be controlled • Installation procedures • Checklist

1 GENERAL DESCRIPTION. .....................................................................................................................3

2 DIMENSIONS .............................................................................................................................................4 2.1 SURFACE MOUNTED MODEL..................................................................................................................4 2.2 FLUSH MOUNTED, MODEL.....................................................................................................................4 2.3 WEATHERPROOF HOUSING (OPTIONAL) ...............................................................................................5 2.4 FLUSH BOX FOR WEATHERPROOF HOUSING (OPTIONAL) ......................................................................5

3 SYSTEM COMPONENTS.........................................................................................................................6 3.1 EXPLODED VIEW...................................................................................................................................6 3.2 MOUNTING BRACKET. ..........................................................................................................................7 3.3 HEATING ELEMENT. (OPTIONAL) ..........................................................................................................7

4 INSTALLATION ........................................................................................................................................8 4.1 PREPARING THE REMOTE CONTROLLER FOR INSTALLATION ................................................................8 4.2 SURFACE INSTALLATION. .....................................................................................................................8 4.3 FLUSH INSTALLATION...........................................................................................................................9 4.4 SURFACE INSTALLATION WITH WEATHERPROOF HOUSING. ...............................................................10 4.5 FLUSH MOUNTED WITH WEATHERPROOF HOUSING. ...........................................................................11

5 POWER REQUIREMENTS....................................................................................................................12 5.1 POWER SUPPLY REQUIREMENTS..........................................................................................................12 5.2 INPUT VOLTAGE RANGE SELECTION. ...................................................................................................12

6 EXTERNAL CONNECTIONS................................................................................................................13

7 CONNECTION ALTERNATIVES. ........................................................................................................15

8 CHECK OF THE INSTALLATION.......................................................................................................17

Copyrights Information in this document is subject to change without further notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of VingCard a.s.

Page 3: Classic Magstripe Remote Controller (Old-LCU1)

06.06.03 3 of 17

1 General description. The Remote Controller is normally installed at doors where there are no space or room for a VingCard lock, or where the item to be controlled is far away from the Card Reader. The Remote Controller is used for controlling such item as; electric strikes, rotary gates, motor locks, garage gates, vehicle barriers e.t.c. The Remote Controller works like a normal card lock. By inserting and retracting a valid key card, the Remote Controller operates the device to be controlled. To operate the device from inside, the Remote Controller must be equipped with an egress switch (ordered separately). The Remote Controller can operate in “Passage” mode, “Normal” mode or “Internal Control” mode. The operations are set up in the VISION /2100 database. The unlock time can also be set up in the VISION /2100 database. A “ Green” LED on front will illuminate indicating that the card is accepted. If an invalid card is inserted a “Red” LED will illuminate.

Page 4: Classic Magstripe Remote Controller (Old-LCU1)

06.06.03 4 of 17

2 Dimensions

2.1 Surface mounted model

Height Width Depth Outside dimensions 7.9” / 200 mm 3.3” / 83 mm 2,5” / 64,5 mm Front 7.9” / 200 mm 3.3” / 83 mm 1” / 24mm

2.2 Flush mounted, model

Height Width Depth Outside dimensions 7.9” / 200 mm 3.3” / 83 mm 2,4” / 63 mm Front cover plate 8,6”/220 mm 4.0”/103 mm 0,1” / 2.5. mm Front Escutcheon 7.9” / 200 mm 3.3” / 83 mm 1” / 24mm

Page 5: Classic Magstripe Remote Controller (Old-LCU1)

06.06.03 5 of 17

2.3 Weatherproof Housing (optional)

2.4 Flush box for Weatherproof Housing (optional)

Height Width Depth Necessary cut-out in the wall 10.4” / 265 mm 4.5” / 115 mm 2.8” / 72 mm Flange 12.5” / 320 mm 6.1” / 155 mm 0.14” / 3.5 mm

Page 6: Classic Magstripe Remote Controller (Old-LCU1)

06.06.03 6 of 17

3 System Components

3.1 Exploded view

Tamper handle

Connection board

Tamper switch Main Board

Housing

Lock Control unit, (LCU)

5537 Cylinder Side view Exploded view

1 - Mounting bracket. 2 - Housing. 3 - Plate for flush mounting 4 - Front Escutcheon. 5 - 5537 Cylinder

Page 7: Classic Magstripe Remote Controller (Old-LCU1)

06.06.03 7 of 17

3.2 Mounting bracket.

Mounting bracket

3.3 Heating element. (optional)

If the Remote Controller is installed in areas where temperature might fall below 0º (32ºF), it is recommended to use the heating element to ensure proper operation.

Heating element

A mounting bracket is always provided with the delivery of the Remote Controller. The Mounting bracket is supplied with 4 nuts (1) for mounting the Housing. The screws for installing the Mounting bracket (2) to the wall or into the recess in the wall are not included.

1 2

1. Connect the jumper wires on the Heating element according to the output voltage for the external power supply

2. Install Heating Element into the slot at the bottom of the Housing.

3. Plug the connector into the mating connector on the connection board

4. Power to the Heating element must be applied to terminal 11 and12. (See chapter 6)

Page 8: Classic Magstripe Remote Controller (Old-LCU1)

06.06.03 8 of 17

3

1

1 2

4 Installation

4.1 Preparing the Remote Controller for installation

4.1.1 Remove the Escutcheon by inserting the key into the cylinder, and turn the key anti clockwise, until the Escutcheon is released from the Housing.

4.1.2 Disconnect the ribbon cable between the Main board on the Escutcheon and the Connection board

4.2 Surface installation.

Surface installation Surface Installation Remote Controller 4.2.1 Position the Remote Controller and mark where it should be installed on the wall. 4.2.2 Install the Mounting plate securely to the wall with four suitable screws. (Mounting

screws are not included) 4.2.3 Drill a hole through the wall for the cables. 4.2.4 Insert the Remote Controller housing onto the 4 posts located on the fixing plate.

Apply the washers and tighten the 4 nuts 4.2.5 Connect the cables from the Power Supply and the cables to the device to be

controlled (See chapter 6) 4.2.6 Connect the ribbon cable between the Main board on Escutcheon and the

Connection board 4.2.7 Mount the Escutcheon by inserting the key into the cylinder and turn the key

clockwise until the Escutcheon is secured

Page 9: Classic Magstripe Remote Controller (Old-LCU1)

06.06.03 9 of 17

21

3

1

4.3 Flush installation.

Remote Controller 6866

Flush installation

4.3.1 Set the position for the Remote Controller and mark where it should be installed into the wall and make a recess in the wall according to the cut-out dimensions

4.3.2 Install the Fixing plate securely in the recess in the wall with four suitable screws. (Mounting screws are not included)

4.3.3 Drill a hole through the wall for the cables. 4.3.4 Insert the Remote Controller housing onto the 4 posts located on the fixing plate.

Apply the washers and tighten the 4 nuts 4.3.5 Connect the cables from the Power Supply and the cables to the device to be

controlled (See chapter 6) 4.3.6 Connect the ribbon cable between the Main board on Escutcheon and the

Connection board 4.3.7 Mount the Escutcheon by inserting the key into the cylinder and turn the key

clockwise until the Escutcheon is secured

Page 10: Classic Magstripe Remote Controller (Old-LCU1)

06.06.03 10 of 17

21

1

5

3

4

4.4 Surface installation with Weatherproof Housing.

Remote Controller 6866 Surface installation with weatherproof Housing

4.4.1 Positioning the Remote Controller and mark where it should be installed onto the wall.

4.4.2 Install the Mounting plate securely to the wall with four suitable screws. (Mounting screws are not included)

4.4.3 Drill a hole through the wall for the cables. 4.4.4 Install the Weather proof housing to the Mounting plate and then insert the Remote

Controller housing onto the 4 posts located on the fixing plate. Apply the washers and tighten the 4 nuts

4.4.5 Connect the cables from the Power Supply and the cables to the device to be controlled (See chapter 6)

4.4.6 Connect the ribbon cable between the Main board on Escutcheon and the Connection board

4.4.7 Mount the Escutcheon by inserting the key into the cylinder and turn the key clockwise until the Escutcheon is secured

Note

Silicone must be applied around the top and sides of the Weather proof housing to prevent condensation from the wall leaking into the Remote Controller.

The cable hole through the wall must be sealed with silicon or similar. This is necessary for 2 purposes: 1. Prevent airflow through the Remote Controller. The airflow might cause

condensation of water inside the Remote Controller, which might cause malfunctions

2. To maintain the fire rate of the wall

Page 11: Classic Magstripe Remote Controller (Old-LCU1)

06.06.03 11 of 17

21

33°

7

5

3

1

4

6

4.5 Flush mounted with Weatherproof Housing.

Remote Controller Flush mounted with weatherproof

housing

4.5.1 Set the position for the Remote Controller and mark where it should be installed into the wall and make a recess in the wall according to the cut-out dimensions

4.5.2 Install the Fixing plate securely in the recess in the wall with four suitable screws. (Mounting screws are not included)

4.5.3 Drill a hole through the wall for the cables. 4.5.4 Install the flush box, then the weatherproof housing and at last the Card-Reader

housing onto the 4 posts located on the fixing plate. Apply the washers and tighten the 4 nuts

4.5.5 Connect the cables from the Power Supply and the cables to the device to be controlled (See chapter 6)

4.5.6 Connect the ribbon cable between the Main board on Escutcheon and the Connection board

4.5.7 Mount the Escutcheon by inserting the key into the cylinder and turn the key clockwise until the Escutcheon is secured

Note

Silicone must be applied around the top and sides of the Weather proof housing to prevent condensation from the wall leaking into the Remote Controller.

The cable hole through the wall must be sealed with silicon or similar. This is necessary for 2 purposes: 1. Prevent airflow through the Remote Controller. The airflow might cause

condensation of water inside the Remote Controller, which might cause malfunctions

2. To maintain the fire rate of the wall

Page 12: Classic Magstripe Remote Controller (Old-LCU1)

06.06.03 12 of 17

5 Power requirements.

5.1 Power supply requirements.

Min. Volt Max. Volt Standby current Active current 6866 (Plug X4, Range I) 10,8 V 30,0 VAC 15 mA 150 mA 6866 (Plug X4, Range I) 15.0 V 40,0 V DC 15 mA 150 mA 6866 (Plug X4, Range II) 10,8V 15,0 V DC 15 mA 150 mA Heating element (24V) 24V +/-20% AC/DC 0,8 A Heating element (12V) 12V +/-20% AC/DC 1,6 A An External 12V or 24V DC power supply must be connected to the Remote Controller. The power supply is not delivered with the Remote Controller, and must be ordered separately. If you want the Remote Controller to operate also when the Main Power fails the external power supply must be connected to an UPS (Uninterruptible Power Supply). To decide the required capacity of Power Supply /UPS, all the external connected equipment (electronic strike, motor locks), power consumption must also be added. For outdoors installations or installations were the temperature might fall below 0º (32ºF) it is recommended to use the optional Heating Element. The heating element can, if desirable, be powered by a separate power supply

5.2 Input voltage range selection.

Use the jumper connectors on Main board to select the correct voltage input, according to the voltage output of the power supply. Range I (as delivered from factory) The Power supply can be 10,8 VAC – 30 VAC or 15 VDC – 40 VDC Range II The Power supply can be 10,8 VDC – 15 VDC

Page 13: Classic Magstripe Remote Controller (Old-LCU1)

06.06.03 13 of 17

6 External connections

(See next page for a more detailed description of the connections)

13 £

Doo

r Sen

sor

14 £

Doo

r Sen

sor

15 £

Tam

per O

utpu

t 16

£ T

ampe

r Out

put

17 £

Lat

ch S

enso

r 18

£ L

atch

Sen

sor

19 £

Priv

acy

20 £

Priv

acy

Ear

th G

roun

d £

1E

gres

s £ 2

Egr

ess £

3In

put f

rom

Pow

er S

uppl

y (+

) £ 4

Inpu

t fro

m P

ower

Sup

ply

(-) £

5O

utpu

t Pow

er (+

) £ 6

Out

put P

ower

(-) £

7N

orm

ally

Clo

sed

Rela

y Te

rmin

al £

8C

omm

on R

elay

Ter

min

al £

9N

orm

ally

Ope

n Re

lay

Term

inal

£ 1

0Po

wer

supp

ly fo

r Hea

ting

Ele

men

t £ 1

1Po

wer

supp

ly fo

r Hea

ting

Ele

men

t £ 1

2

Page 14: Classic Magstripe Remote Controller (Old-LCU1)

06.06.03 14 of 17

Terminal number 1. Earth Ground Connect this terminal to building earth

2&3 Egress Input for a normally open push button switch. Output Relay is activated for a preset time period, by momentarily pressing this switch. Used to unlock the door from inside.

4&5 Power supply input 12/24V power supply input, where terminal 4 is + and terminal 5 is –

6&7 Power supply output Terminal 6 is connected to terminal 4, and terminal 7 is connected to terminal 5.

8 NC (Normally closed) Relay output. Connected to common (terminal 9) when output relay is not activated

9 Common Relay output. Centre contact for NC and NO.

10 NO (Normally open) Relay output. Connected to common (terminal 9) when output relay is activated

11&12 Power supply input for Heating element

Power supply input for the heating element (12V AC/DC 1.6A or 24V AC/DC 0.8A)

13&14 Door sensor input A door sensor determines if the door is closed. If this sensor is connected, the output relay will deactivate as soon as the door is closed. Use a sensor with contacts that opens when the door is closed

15&16 Tamper Output Connected to a normally closed switch inside the Remote Controller. This switch opens if the Remote Controller is opened or removed from wall. A security alarm system can be connected to these terminals.

17&18 Latch Sensor input Not in use

19&20 Privacy switch input Input, for connecting a Privacy indicator switch. When the switch is closed, only keycards set up with deadbolt override are granted access.

Page 15: Classic Magstripe Remote Controller (Old-LCU1)

06.06.03 15 of 17

7 Connection alternatives. 9.1 Alternative 1 Voltage will be applied to load, when a valid key card is inserted, or the egress switch depressed 9.2 Alternative 2 Voltage is disconnected from load, when a valid key card is inserted, or the egress switch depressed

POWER SUPPLY

REMOTE CONTROLLER 2 3

1 4 5 6 7 9 10 8

C NO NC LOAD

15 16 11 12

13 14 17 18 19 20

POWER SUPPLY

1 4 5 6 7 9 10 8

C NO NC LOAD

15 16 11 12

13 14 17 18 19 20 2 3 REMOTE CONTROLLER

Egress switch

Egress switch

Page 16: Classic Magstripe Remote Controller (Old-LCU1)

06.06.03 16 of 17

9.3 Alternative 3. Acts like a normally closed switch. Contacts open when a valid keycard is inserted, or the egress switch depressed 9.4 Alternative 4. Acts like a normally open switch. Contacts close when a valid keycard is inserted, or the egress switch depressed

POWER SUPPLY

LOAD

1 4 5 6 7 9 10 8

15 16 11 12

13 14 17 18 19 20

REMOTE CONTROLLER

POWER SUPPLY

LOAD

1 4 5 6 7 9 10 8

15 16 11 12

13 14 17 18 19 20

REMOTE CONTROLLER

C NO NC

2 3

2 3

C NO NC

Egress switch

Egress switch

Page 17: Classic Magstripe Remote Controller (Old-LCU1)

06.06.03 17 of 17

8 Check of the installation. Check the following:

8.1.1 The Remote Controller is mounted at a suitable height and sidewalls are is in a vertical position.

8.1.2 All cables are properly fixed, and located either in the wall or in surface conduits. 8.1.3 No cables are pinched. 8.1.4 Door and locking devices are operating properly. 8.1.5 All holes are filled or sealed. 8.1.6 The power consumption is not higher than what the Power Supply provides. (See

Power supply requirements). 8.1.7 Check the Function of all external devices.