    CKMC5 – Data Sheet  Pag. 1/3 

    CKMC5Super Slim PWM Control ler / SoftStart for DC Loads

    Datasheet V3.0

  • 8/16/2019 Ckmc5 Datasheet Uk v3 0 Www 20.10.11--With-new-logo

    2/3

     

    CKMC5 – Data Sheet  Pag. 2/3 

    1. Features

    The CKMC module can be used for:•  allowing to operate high inrush current loads in conjunction with power supplies that

    have low overload capability or hiccup type of current limitation.

    •  DC loads where a power regulation is necessary, for example in motors and lamps.Remote power regulation is possible by use of an external potentiometer.

    The used technique is PWM (Pulse Width Modulation).It is equipped with a SoftStart circuit in order to avoid the known current peaks problemson inductive, capacitive or high dynamic loads as motors, lamps, coils and power supplies.The power level and the SoftStart duration are adjustable through two internal

    potentiometers.When an external potentiometer is used for remote power regulation this mode is settablethrough an internal switch (SW1).

    2. Technical data

    Parameter Range Remarks

    U supply forcontrol side (UIN) 

    24Vdc (factory set) or 12Vdc Custom voltages available onrequest.

    UOUT (load) 48Vdc max.

    IOUT (load) 4A nominal, max. 6A for 30 s

    SoftStart duration adjustable 0.5 - 5.0s

    Power level range adjustable 0 - 100%

    Protections (loadside)

    - short circuit (T fuse)- reverse polarity- transient over voltage

    Connections 5 clamp contacts for AWG26-14 wire

    Mechanical Plastic enclosure (UL 94 V-0) for DINrail, total width = 6mm 

    The smallest width in themarket !

    Environmental Temperature operating range:-10/+45°C

    Humidity: max. 85%, non condensing

    Higher temperature (max.60°C) possible with load

    derating, 150mA/°C

    3. WARNING!

    Before powering the unit check as follows:

    •  In and out polarity

    •  In and out voltage, UIN max = 28VDC (or 15VDC) and UOUT max = 48VDC

    •  Max. load current, IOUT max = 4A

  • 8/16/2019 Ckmc5 Datasheet Uk v3 0 Www 20.10.11--With-new-logo

    3/3

     

    CKMC5 – Data Sheet  Pag. 3/3 

    4. Block diagram

    100% 0% max min

    Power regulation     SoftStart duration regulation

    Power regulation is always active, with SoftStart ON or SoftStart OFF. SoftStart durationregulation is active with SoftStart ON.

    5. SoftStart settings

    With internal potentiometer:ON   SW1-1 ON OFF   SW1-1 ON

    SW1-2 ON SW1-2 OFFSW1-3 OFF SW1-3 OFFSW1-4 OFF SW1-4 OFF

    With external potentiometer:ON   SW1-1 OFF OFF   SW1-1 OFF

    SW1-2 OFF SW1-2 OFFSW1-3 ON SW1-3 ONSW1-4 ON SW1-4 OFF