Civil & Structural Engineering Design Services Pty. Ltd. Client: EXTREME MARQUEES PTY. LTD. Project: Design check – 24.4m x 12.2m x 6.4m The Platoon Tent Structure (3m Bay) for 80km/hr Wind Speed. Reference: Extreme Marquees Pty Ltd Technical Data Report by: KZ Checked by: EAB Date: 21/02/2017 JOB NO: E-11-265139

Civil & Structural Engineering Design Services Pty. Ltd. · Number of Intermediate Purlin 4 h/d 0.22 h/b 0.43 Wind Pressure ρair ρ 1.2 Kg/m3 dynamic response factor C dyn 1 Wind

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • Civil & Structural Engineering Design Services Pty. Ltd. Client: EXTREME MARQUEES PTY. LTD. Project: Design check – 24.4m x 12.2m x 6.4m The Platoon Tent Structure (3m Bay) for 80km/hr Wind Speed. Reference: Extreme Marquees Pty Ltd Technical Data

    Report by: KZ Checked by: EAB Date: 21/02/2017 JOB NO: E-11-265139

  • Civil & Structural Engineering Design Services Pty. Ltd.

    2 | P a g e ABN: 62 051 307 852 3 Wanniti Road BELROSE NSW 2085 Tel: 02 9975 3899 Fax: 02 99751943

    Email: [email protected] Web: www.civilandstructural.com.au

    Table of Contents

    1 Introduction ....................................................................................................................................................... 3

    Design Restrictions and Limitations ............................................................................................................................. 4

    2 Specifications ..................................................................................................................................................... 5

    2.1 General ...................................................................................................................................................... 5

    2.2 Steel Properties .......................................................................................................................................... 6

    2.3 Members..................................................................................................................................................... 6

    3 Design Loads ..................................................................................................................................................... 6

    3.1 Ultimate ..................................................................................................................................................... 6

    3.2 Load Combinations ..................................................................................................................................... 6

    3.2.1 Serviceability ..................................................................................................................................... 6

    3.2.2 Ultimate ............................................................................................................................................. 6

    4 Wind Analysis .................................................................................................................................................... 7

    4.1 Parameters ................................................................................................................................................. 7

    4.2 Pressure Coefficients (Cfig).......................................................................................................................... 7

    4.2.1 Pressure summary ............................................................................................................................ 15

    4.3 Wind Load Diagrams ................................................................................................................................ 16

    4.3.1 Wind 1(case 1) ................................................................................................................................. 16

    4.3.2 Wind 1(case 2) ................................................................................................................................. 16

    4.3.3 Wind 2(Case1) ................................................................................................................................. 17

    4.3.4 Wind 2(case 2) ................................................................................................................................. 17

    4.3.5 Max Bending Moment due to critical load combination in major axis ................................................ 18

    4.3.6 Max Bending Moment in minor axis due to critical load combination ................................................ 18

    4.3.7 Max Shear in due to critical load combination .................................................................................. 19

    4.3.8 Max Axial force in upright support and roof beam due to critical load combination........................... 19

    4.3.9 Max reactions................................................................................................................................... 20

    5 Checking Members Based on AS4100:1998 ...................................................................................................... 20

    6 Summary .......................................................................................................................................................... 21

    6.1 Conclusions .............................................................................................................................................. 21

    7 Appendix A – Base Anchorage Requirements .................................................................................................... 22

    8 Appendix B – Hold Down Method Details ........................................................................................................ 23

    mailto:[email protected]://www.civilandstructural.com.au/

  • Civil & Structural Engineering Design Services Pty. Ltd.

    3 | P a g e ABN: 62 051 307 852 3 Wanniti Road BELROSE NSW 2085 Tel: 02 9975 3899 Fax: 02 99751943

    Email: [email protected] Web: www.civilandstructural.com.au

    1 Introduction

    This ‘Certification’ is the sole property for copyright to Mr. Ted Bennett of Civil & Structural Engineering Design

    Services Pty. Ltd.

    The following structural drawings and calculations are for the transportable tents supplied by Extreme Marquees.

    The frame consists principally of extruded hot dipped galvanized steel trusses and base plates.

    The report examines the effect of 3s gust wind of 80 km/hr on 24.4m × 12.2m x 6.4m The Platoon Tent as the worst-

    case scenario. The relevant Australian Standards AS1170.0:2002 General principles, AS1170.1:2002 Permanent,

    imposed and other actions and AS1170.2:2011 Wind actions are used. The design check is in accordance with AS/NZS

    4100:1998 Steel Structures.

    mailto:[email protected]://www.civilandstructural.com.au/

  • Civil & Structural Engineering Design Services Pty. Ltd.

    4 | P a g e ABN: 62 051 307 852 3 Wanniti Road BELROSE NSW 2085 Tel: 02 9975 3899 Fax: 02 99751943

    Email: [email protected] Web: www.civilandstructural.com.au

    Design Restrictions and Limitations

    2.1 The erected structure is for temporary use only.

    2.2 It should be noted that if high gust wind speeds are anticipated or forecast in the locality of the tent, the temporary

    erected structure should be dismantled.

    2.3 For forecast winds in excess of (refer to summary) – all fabric shall be removed from the frames, and the

    structure should be completely dismantled.

    (Please note that the locality squall or gust wind speed is affected by factors such as terrain exposure and site

    elevations.)

    2.4 The structure may only be erected in regions with wind classifications no greater than the limits specified on the

    attached wind analysis.

    2.5 The wind classifications are based upon Terrain Category 2. Considerations have also been made to the regional

    wind terrain category, topographical location and site shielding from adjacent structures. Please note that in many

    instances topographical factors such as a location on the crest of a hill or on top of an escarpment may yield a

    higher wind speed classification than that derived for a higher wind terrain category in a level topographical

    region. For this reason, particular regard shall be paid to the topographical location of the structure. For localities

    which do not conform to the standard prescribed descriptions for wind classes as defined above, a qualified

    Structural Engineer may be employed to determine an appropriate wind class for that the particular site.

    2.6 The structures in no circumstances shall ever be erected in tropical or severe tropical cyclonic condition as defined

    on the Map of Australia in AS 1170.2-2011, Figure 3.1.

    2.7 The tent structure has not been designed to withstand snow and ice loadings such as when erected in alpine

    regions.

    2.8 For the projects, where the site conditions approach the design limits, extra consideration should be given to

    pullout tests of the stakes and professional assessment of the appropriate wind classification for the site.

    2.9 The tents are stabilized as using roof/wall cross bracing at end bays as shown on the drawings.

    mailto:[email protected]://www.civilandstructural.com.au/

  • Civil & Structural Engineering Design Services Pty. Ltd.

    5 | P a g e ABN: 62 051 307 852 3 Wanniti Road BELROSE NSW 2085 Tel: 02 9975 3899 Fax: 02 99751943

    Email: [email protected] Web: www.civilandstructural.com.au

    2 Specifications

    2.1 General

    Tent category

    Material Steel 350 Mpa

    Size Model

    24.4m x 12.2m The Platoon

    mailto:[email protected]://www.civilandstructural.com.au/

  • Civil & Structural Engineering Design Services Pty. Ltd.

    6 | P a g e ABN: 62 051 307 852 3 Wanniti Road BELROSE NSW 2085 Tel: 02 9975 3899 Fax: 02 99751943

    Email: [email protected] Web: www.civilandstructural.com.au

    2.2 Steel Properties

    Steel Properties

    Minimum Yeild Stress Fy 350 Mpa

    Young’s modulus E 2.0 Mpa

    Possion Ratio Ftu 0.25

    Shear yield strength Fsy 138 Mpa

    Bearing yield strength Fby 386 Mpa

    Bearing ultimate strength Fbu 552 Mpa

    2.3 Members

    Sections

    300mm Truss 60 x 1.5 CHS (Top & Bottom Chord)

    300mm Truss 60 x 1.5 CHS (Web )

    Cross Brace 60 x 1.5 CHS

    Cable Brace 8

    Roof Purlin 60 x 1.5 CHS

    Gable Beam & Pole 60 x 1.5 CHS

    3 Design Loads

    3.1 Ultimate

    Distributed load (kPa) Design load factor (-) Factored imposed load (kPa)

    Live Q - 1.5 -

    Self weight G self weight 1.35, 1.2, 0.9 1.2 self weight, 0.9 self weight

    3s 80km/hr gust W 0.245 Cfig 1.0 0.245 Cfig

    3.2 Load Combinations

    3.2.1 Serviceability

    Gravity = 1.0 × G

    Wind = 1.0 × G + 1.0 × W

    3.2.2 Ultimate

    Downward = 1.35 × G

    mailto:[email protected]://www.civilandstructural.com.au/

  • Civil & Structural Engineering Design Services Pty. Ltd.

    7 | P a g e ABN: 62 051 307 852 3 Wanniti Road BELROSE NSW 2085 Tel: 02 9975 3899 Fax: 02 99751943

    Email: [email protected] Web: www.civilandstructural.com.au

    = 1.2 × G + Wu

    = 1.2 × G + Wu +WIS

    Upward = 0.9 × G + Wu

    0.9 × G + Wu+WIP

    4 Wind Analysis

    Wind towards surface (+ve), away from surface (-ve)

    4.1 Parameters Terrain category = 2 Site wind speed (Vsit,β) = VRMd(Mz,catMsMt)

    VR = 22.22m/s (80 km/hr) (regional 3 s gust wind speed)

    Md = 1

    Ms = 1

    Mt = 1

    Mz,cat = 0.91 (Table 4.1(B) AS1170.2)

    Vsit,β = 20.22 m/s

    Height of structure (h) = 5.25 m (mid of peak and eave)

    Width of structure (w) = 12.2 m Length of structure (l) = 24.4 m

    Pressure (P) = 0.5ρair (Vsit,β)2 Cfig Cdyn

    = 0.245Cfig kPa

    4.2 Pressure Coefficients (Cfig)

    Name Symbol Value Unit Notes Ref.

    Input

    Importance level

    2

    Table 3.1 - Table 3.2

    (AS1170.0)

    Annual probability of exceedance

    -

    Table 3.3

    Regional gust wind speed

    80 Km/hr Table 3.1 (AS1170.2)

    Regional gust wind speed VR 22.22 m/s

    Wind Direction Multipliers Md 1

    Table 3.2 (AS1170.2)

    Terrain Category Multiplier MZ,Cat 0.91 Table 4.1 (AS1170.2)

    Shield Multiplier MS 1 4.3 (AS1170.2)

    Topographic Multiplier Mt 1

    4.4 (AS1170.2)

    Site Wind Speed VSite,β 20.22 m/s VSite,β=VR*Md*Mz,cat*MS,Mt

    Pitch α 20 Deg

    mailto:[email protected]://www.civilandstructural.com.au/

  • Civil & Structural Engineering Design Services Pty. Ltd.

    8 | P a g e ABN: 62 051 307 852 3 Wanniti Road BELROSE NSW 2085 Tel: 02 9975 3899 Fax: 02 99751943

    Email: [email protected] Web: www.civilandstructural.com.au

    Pitch α 0.349 rad

    Width B 12.2 m

    Width Span Sw - m

    Length D 24 m

    Height Z 5.25 m

    Bay Span

    3 m

    Purlin Spacing

    2.2 m

    Number of Intermediate Purlin

    4

    h/d 0.22

    h/b 0.43

    Wind Pressure

    ρair ρ 1.2 Kg/m3

    dynamic response factor Cdyn 1

    Wind Pressure ρ*Cfig 0.245 Kg/m2 ρ=0.5ρair*(Vdes,β)2*Cfig*Cdyn 2.4 (AS1170.2)

    WIND DIRECTION 1 (Perpendicular to Length)

    Internal Pressure

    Opening Assumption

    Internal Pressure Coefficient (Without Dominant) MIN

    -0.1

    Table 5.1 A (AS1170.2)

    Internal Pressure Coefficient (Without Dominant) MAX

    0.2

    Internal Pressure Coefficient (With Dominant) MIN

    -0.1

    Table 5.1 B (AS1170.2)

    Internal Pressure Coefficient (With Dominant) MAX

    0.2

    N

    0.3

    Combination Factor KC,i 1

    Internal Pressure Coefficient MIN Cp,i 0.70

    Internal Pressure Coefficient MAX

    Cp,i 0.70

    External Pressure

    mailto:[email protected]://www.civilandstructural.com.au/

  • Civil & Structural Engineering Design Services Pty. Ltd.

    9 | P a g e ABN: 62 051 307 852 3 Wanniti Road BELROSE NSW 2085 Tel: 02 9975 3899 Fax: 02 99751943

    Email: [email protected] Web: www.civilandstructural.com.au

    1. Windward Wall

    External Pressure Coefficient CP,e 0.7 Table 5.2 A

    Area Reduction Factor Ka 1

    Table 5.4

    combination factor applied to internal pressures

    KC,e 0.8

    local pressure factor Kl 1

    porous cladding reduction factor Kp 1

    aerodynamic shape factor Cfig,e 0.56

    Wind Wall Pressure P 0.14 kPa

    Edge Column Force F 0.21 kN/m

    Intermediate Column Force F 0.41 kN/m

    2. Leeward Wall

    External Pressure Coefficient CP,e -0.4

    Table 5.2 B

    Area Reduction Factor Ka 1 Table 5.4

    combination factor applied to internal pressures

    KC,e 0.8

    local pressure factor Kl 1

    porous cladding reduction factor Kp 1

    aerodynamic shape factor Cfig,e -0.32

    Lee Wall Pressure P -0.08 kPa

    Edge Column Force F -0.12 kN/m

    Intermediate Column Force F -0.24 kN/m

    3. Side Wall

    Table 5.2 C

    Area Reduction Factor Ka 1 Table 5.4

    combination factor applied to internal pressures

    KC,e 0.8

    local pressure factor Kl 1

    porous cladding reduction factor Kp 1

    External Pressure Coefficient CP,e -0.65

    0 to 1h

    External Pressure Coefficient CP,e -0.5

    1h to 2h

    External Pressure Coefficient CP,e -0.3

    2h to 3h

    External Pressure Coefficient CP,e -0.2 >3h

    aerodynamic shape factor Cfig,e -0.52

    0 to 1h

    aerodynamic shape factor Cfig,e -0.4

    1h to 2h

    aerodynamic shape factor Cfig,e -0.24

    2h to 3h

    aerodynamic shape factor Cfig,e -0.16 >3h

    Side Wall Pressure P -0.13 kPa 0 to 1h

    Side Wall Pressure P -0.10 kPa 1h to 2h

    mailto:[email protected]://www.civilandstructural.com.au/

  • Civil & Structural Engineering Design Services Pty. Ltd.

    10 | P a g e ABN: 62 051 307 852 3 Wanniti Road BELROSE NSW 2085 Tel: 02 9975 3899 Fax: 02 99751943

    Email: [email protected] Web: www.civilandstructural.com.au

    Side Wall Pressure P -0.06 kPa 2h to 3h

    Side Wall Pressure P -0.04 kPa >3h

    4. Roof

    α>10o

    r (rise) r 2.3 m

    h/r h/r 2.28

    Breadth Effect

    1.18

    (b/d)^0.25>1

    Rise-to-span ratio r/d 0.19

    4.1 Roof Windward Quarter

    U U 3.05 m

    Area Reduction Factor Ka 1

    combination factor applied to internal pressures

    KC,e 0.8

    local pressure factor Kl 1

    porous cladding reduction factor Kp 1

    External Pressure Coefficient MIN

    CP,e -0.61 Table C3

    External Pressure Coefficient MAX

    CP,e 0

    Factored External Pressure Coefficient MIN

    CP,e -0.72

    Factored External Pressure Coefficient MAX

    CP,e 0.00

    aerodynamic shape factor MIN Cfig,e -0.58

    aerodynamic shape factor MAX Cfig,e 0.00

    Pressure MIN P -0.14 kPa

    Pressure MAX P 0.00 kPa

    Edge Rafter Force MIN F -0.21 kN/m

    Edge Rafter Force Max F 0.00 kN/m

    Intermediate Rafter Force MIN F -0.43 kN/m

    Intermediate Rafter Force MAX F 0.00 kN/m

    4.2 Roof Centre Half

    T T 6.1 m

    Area Reduction Factor Ka 1

    combination factor applied to internal pressures

    KC,e 0.8

    local pressure factor Kl 1

    porous cladding reduction factor Kp 1

    External Pressure Coefficient MIN

    CP,e -1.01

    Table C3

    External Pressure Coefficient MAX

    CP,e -1.01

    Factored External Pressure Coefficient MIN

    CP,e -1.19

    Factored External Pressure Coefficient MAX

    CP,e -1.19

    aerodynamic shape factor MIN Cfig,e -0.95

    mailto:[email protected]://www.civilandstructural.com.au/

  • Civil & Structural Engineering Design Services Pty. Ltd.

    11 | P a g e ABN: 62 051 307 852 3 Wanniti Road BELROSE NSW 2085 Tel: 02 9975 3899 Fax: 02 99751943

    Email: [email protected] Web: www.civilandstructural.com.au

    aerodynamic shape factor MAX Cfig,e -0.95

    Pressure MIN P -0.23 kPa

    Pressure MAX P -0.23 kPa

    Edge Rafter Force MIN F -0.35 kN/m

    Edge Rafter Force Max F -0.35 kN/m

    Intermediate Rafter Force MIN F -0.70 kN/m

    Intermediate Rafter Force MAX F -0.70 kN/m

    4.1 Roof Windward Quarter

    D D 3.05 m

    Area Reduction Factor Ka 1

    combination factor applied to internal pressures

    KC,e 0.8

    local pressure factor Kl 1

    porous cladding reduction factor Kp 1

    External Pressure Coefficient MIN

    CP,e -0.706 Table C3

    External Pressure Coefficient MAX

    CP,e 0

    Factored External Pressure Coefficient MIN

    CP,e -0.84

    Factored External Pressure Coefficient MAX

    CP,e 0.00

    aerodynamic shape factor MIN Cfig,e -0.67

    aerodynamic shape factor MAX Cfig,e 0.00

    Pressure MIN P -0.16 kPa

    Pressure MAX P 0.00 kPa

    Edge Rafter Force MIN F -0.25 kN/m

    Edge Rafter Force Max F 0.00 kN/m

    Intermediate Rafter Force MIN F -0.49 kN/m

    Intermediate Rafter Force MAX F 0.00 kN/m

    WIND DIRECTION 2 (Parallel to Length)

    Internal Pressure

    Opening Assumption

    Internal Pressure Coefficient (Without Dominant) MIN

    -0.1

    Table 5.1 A (AS1170.2)

    Internal Pressure Coefficient (Without Dominant) MAX

    0.2

    mailto:[email protected]://www.civilandstructural.com.au/

  • Civil & Structural Engineering Design Services Pty. Ltd.

    12 | P a g e ABN: 62 051 307 852 3 Wanniti Road BELROSE NSW 2085 Tel: 02 9975 3899 Fax: 02 99751943

    Email: [email protected] Web: www.civilandstructural.com.au

    Internal Pressure Coefficient (With Dominant) MIN

    -0.1

    Table 5.1 B (AS1170.2)

    Internal Pressure Coefficient (With Dominant) MAX

    0.2

    N

    0.3

    Cpi= N*Cpe

    Combination Factor KC,i 1

    Internal Pressure Coefficient MIN Cp,i 0.70

    Internal Pressure Coefficient MAX

    Cp,i 0.70

    External Pressure

    1. Windward Wall

    External Pressure Coefficient CP,e 0.7 Table 5.2 A

    Area Reduction Factor Ka 1

    Table 5.4

    combination factor applied to internal pressures

    KC,e 0.8

    local pressure factor Kl 1

    porous cladding reduction factor Kp 1

    aerodynamic shape factor Cfig,e 0.56

    Wind Wall Pressure P 0.14 kPa

    Edge Column Force F #VALUE! kN/m

    Intermediate Column Force F #VALUE! kN/m

    2. Leeward Wall

    External Pressure Coefficient CP,e -0.3 Table 5.2 B

    Area Reduction Factor Ka 1 Table 5.4

    combination factor applied to internal pressures

    KC,e 0.8

    local pressure factor Kl 1

    porous cladding reduction factor Kp 1

    aerodynamic shape factor Cfig,e -0.24

    Lee Wall Pressure P -0.06 kPa

    Edge Column Force F #VALUE! kN/m

    Intermediate Column Force F #VALUE! kN/m

    3. Side Wall

    Table 5.2 C

    Area Reduction Factor Ka 1 Table 5.4

    combination factor applied to internal pressures

    KC,e 0.8

    local pressure factor Kl 1

    porous cladding reduction factor Kp 1

    External Pressure Coefficient CP,e -0.65 0 to 1h

    External Pressure Coefficient CP,e -0.5 1h to 2h

    External Pressure Coefficient CP,e -0.3 2h to 3h

    mailto:[email protected]://www.civilandstructural.com.au/

  • Civil & Structural Engineering Design Services Pty. Ltd.

    13 | P a g e ABN: 62 051 307 852 3 Wanniti Road BELROSE NSW 2085 Tel: 02 9975 3899 Fax: 02 99751943

    Email: [email protected] Web: www.civilandstructural.com.au

    External Pressure Coefficient CP,e -0.2 >3h

    aerodynamic shape factor Cfig,e -0.52

    0 to 1h

    aerodynamic shape factor Cfig,e -0.4

    1h to 2h

    Side Wall Pressure P -0.13 kPa 0 to 1h

    Side Wall Pressure P -0.10 kPa 1h to 2h

    Side Wall Pressure P -0.06 kPa 2h to 3h

    Side Wall Pressure P -0.04 kPa >3h

    4. Roof

    α3h

    External Pressure Coefficient MAX

    CP,e -0.40 0 to 0.5h

    External Pressure Coefficient MAX

    CP,e -0.40 0.5 to 1h

    External Pressure Coefficient MAX

    CP,e 0.00 1h to 2h

    External Pressure Coefficient MAX

    CP,e 0.10 2h to 3h

    External Pressure Coefficient MAX

    CP,e 0.20

    >3h

    aerodynamic shape factor MIN Cfig,e -0.72

    0 to 0.5h

    aerodynamic shape factor MIN Cfig,e -0.72 0.5 to 1h

    aerodynamic shape factor MIN Cfig,e -0.4

    1h to 2h

    aerodynamic shape factor MIN Cfig,e -0.24 2h to 3h

    aerodynamic shape factor MIN Cfig,e -0.16 >3h

    aerodynamic shape factor MAX Cfig,e -0.32 0 to 0.5h

    aerodynamic shape factor MAX Cfig,e -0.32

    0.5 to 1h

    mailto:[email protected]://www.civilandstructural.com.au/

  • Civil & Structural Engineering Design Services Pty. Ltd.

    14 | P a g e ABN: 62 051 307 852 3 Wanniti Road BELROSE NSW 2085 Tel: 02 9975 3899 Fax: 02 99751943

    Email: [email protected] Web: www.civilandstructural.com.au

    aerodynamic shape factor MAX Cfig,e 0 1h to 2h

    aerodynamic shape factor MAX Cfig,e 0.08

    2h to 3h

    aerodynamic shape factor MAX Cfig,e 0.16

    >3h

    Pressure MIN P -0.18 kPa 0 to 0.5h

    Pressure MIN P -0.18 kPa 0.5 to 1h

    Pressure MIN P -0.10 kPa 1h to 2h

    Pressure MIN P -0.06 kPa 2h to 3h

    Pressure MIN P -0.04 kPa >3h

    Pressure MAX P -0.08 kPa 0 to 0.5h

    Pressure MAX P -0.08 kPa 0.5 to 1h

    Pressure MAX P 0.00 kPa 1h to 2h

    Pressure MAX P 0.02 kPa 2h to 3h

    Pressure MAX P 0.04 kPa >3h

    Edge Purlin Force MIN F -0.19 kN/m 0 to 0.5h

    Edge Purlin Force MIN F -0.19 kN/m 0.5 to 1h

    Edge Purlin Force MIN F -0.11 kN/m 1h to 2h

    Edge Purlin Force MIN F -0.06 kN/m 2h to 3h

    Edge Purlin Force MIN F -0.04 kN/m >3h

    Edge Purlin Force MAX F -0.09 kN/m 0 to 0.5h

    Edge Purlin Force MAX F -0.09 kN/m 0.5 to 1h

    Edge Purlin Force MAX F 0.00 kN/m 1h to 2h

    Edge Purlin Force MAX F 0.02 kN/m 2h to 3h

    Edge Purlin Force MAX F 0.04 kN/m >3h

    Intermediate Purlin Force MIN F -0.39 kN/m 0 to 0.5h

    Intermediate Purlin Force MIN F -0.39 kN/m 0.5 to 1h

    Intermediate Purlin Force MIN F -0.22 kN/m 1h to 2h

    Intermediate Purlin Force MIN F -0.13 kN/m 2h to 3h

    Intermediate Purlin Force MIN F -0.09 kN/m >3h

    Intermediate Purlin Force MAX F -0.17 kN/m 0 to 0.5h

    Intermediate Purlin Force MAX F -0.17 kN/m 0.5 to 1h

    Intermediate Purlin Force MAX F 0.00 kN/m 1h to 2h

    Intermediate Purlin Force MAX F 0.04 kN/m 2h to 3h

    Intermediate Purlin Force MAX F 0.09 kN/m >3h

    mailto:[email protected]://www.civilandstructural.com.au/

  • Civil & Structural Engineering Design Services Pty. Ltd.

    15 | P a g e ABN: 62 051 307 852 3 Wanniti Road BELROSE NSW 2085 Tel: 02 9975 3899 Fax: 02 99751943

    Email: [email protected] Web: www.civilandstructural.com.au

    4.2.1 Pressure summary

    WIND EXTERNAL PRESSURE Direction1 (Perpendicular to Length) Direction2 (Parallel to Length)

    Windward (kPa) 0.14 0.14

    Leeward (kPa) -0.08 -0.06

    Sidewall (m)

    Length (m) (m) (Kpa) (Kpa)

    0 - 1h 0 5.25 -0.13 -0.13

    1h - 2h 5.25 10.5 -0.10 -0.10

    2h - 3h 10.5 15.75 -0.06 -0.06

    >3h 15.75 - -0.04 -0.04

    Roof

    Length (m) (m)

    Min (Kpa)

    Max (Kpa) Length (m) (m) Min

    (Kpa) Max

    (Kpa)

    Windward Quarter

    0 - 0.25d

    0 3.05 -0.14 0.00 0-0.5h 0.00 2.63 -0.18 -0.08

    Centre Half 0.25d - 0.75d

    3.05 9.15 -0.23 -0.23 0.5h-1h 2.63 5.25 -0.18 -0.08

    Leeward Quarter 0.75d -

    1d 9.15 12.2 -0.16 0.00 1h-2h 5.25 10.50 -0.10 0.00

    2h-3h 10.50 15.75 -0.06 0.02

    >3h 15.75 - -0.04 0.04

    Wind Internal Pressure (kPa)

    Min (kPa) Max (kPa) Min (kPa) Max (kPa)

    Proportion of Cpe Proportion

    of Cpe Proportion of Cpe

    Proportion of Cpe

    AS1170.2 Direction 1 Direction 2

    mailto:[email protected]://www.civilandstructural.com.au/

  • Civil & Structural Engineering Design Services Pty. Ltd.

    16 | P a g e ABN: 62 051 307 852 3 Wanniti Road BELROSE NSW 2085 Tel: 02 9975 3899 Fax: 02 99751943

    Email: [email protected] Web: www.civilandstructural.com.au

    4.3 Wind Load Diagrams

    4.3.1 Wind 1(case 1)

    4.3.2 Wind 1(case 2)

    mailto:[email protected]://www.civilandstructural.com.au/

  • Civil & Structural Engineering Design Services Pty. Ltd.

    17 | P a g e ABN: 62 051 307 852 3 Wanniti Road BELROSE NSW 2085 Tel: 02 9975 3899 Fax: 02 99751943

    Email: [email protected] Web: www.civilandstructural.com.au

    4.3.3 Wind 2(Case1)

    4.3.4 Wind 2(case 2)

    After 3D model analysis, each member is checked based on adverse load combination.

    In this regard the maximum bending moment, shear and axial force due to adverse load combinations for each member

    are presented as below:

    mailto:[email protected]://www.civilandstructural.com.au/

  • Civil & Structural Engineering Design Services Pty. Ltd.

    18 | P a g e ABN: 62 051 307 852 3 Wanniti Road BELROSE NSW 2085 Tel: 02 9975 3899 Fax: 02 99751943

    Email: [email protected] Web: www.civilandstructural.com.au

    4.3.5 Max Bending Moment due to critical load combination in major axis

    4.3.6 Max Bending Moment in minor axis due to critical load combination

    mailto:[email protected]://www.civilandstructural.com.au/

  • Civil & Structural Engineering Design Services Pty. Ltd.

    19 | P a g e ABN: 62 051 307 852 3 Wanniti Road BELROSE NSW 2085 Tel: 02 9975 3899 Fax: 02 99751943

    Email: [email protected] Web: www.civilandstructural.com.au

    4.3.7 Max Shear in due to critical load combination

    4.3.8 Max Axial force in upright support and roof beam due to critical load combination

    mailto:[email protected]://www.civilandstructural.com.au/

  • Civil & Structural Engineering Design Services Pty. Ltd.

    20 | P a g e ABN: 62 051 307 852 3 Wanniti Road BELROSE NSW 2085 Tel: 02 9975 3899 Fax: 02 99751943

    Email: [email protected] Web: www.civilandstructural.com.au

    4.3.9 Max reactions

    Max Reaction (Bearing) N* = 5.3 kN

    Max Reaction (Uplift) N* = 8.35 kN

    5 Checking Members Based on AS4100:1998

    All Members pass

    mailto:[email protected]://www.civilandstructural.com.au/

  • Civil & Structural Engineering Design Services Pty. Ltd.

    21 | P a g e ABN: 62 051 307 852 3 Wanniti Road BELROSE NSW 2085 Tel: 02 9975 3899 Fax: 02 99751943

    Email: [email protected] Web: www.civilandstructural.com.au

    6 Summary

    6.1 Conclusions

    a. The 12.2m x 24.4m The Platoon Tent structure as specified has been analyzed with a conclusion that it has the

    capacity to withstand wind speeds up to and including 80km/hr.

    b. For forecast winds in excess of 80km/hr – all fabric shall be removed from the frames, and the structure should

    be completely dismantled.

    c. Wall cross bracing as well as roof cable bracing are required at each end bay to resist against lateral movement

    due to wind direction2.

    d. For uplift due to 80km/hr, 10 kN (1T) holding down weight/per leg for upright support is required.

    e. The bearing pressure of soil should be clarified and checked by an engineer prior to any construction for

    considering foundation and base plate.

    f. Bracing Cables are required to have the minimum tensile strength (SWL) equal to 10kN.

    g. Design of fabric by others.

    Yours faithfully,

    E.A. Bennett M.I.E. Aust. NPER 198230

    mailto:[email protected]://www.civilandstructural.com.au/

  • Civil & Structural Engineering Design Services Pty. Ltd.

    22 | P a g e ABN: 62 051 307 852 3 Wanniti Road BELROSE NSW 2085 Tel: 02 9975 3899 Fax: 02 99751943

    Email: [email protected] Web: www.civilandstructural.com.au

    7 Appendix A – Base Anchorage Requirements

    24.4m x 12.2m x 6.4m The Platoon Tent Structure:

    Tent Span Sile Type Required Weight Per Leg

    12.2 m

    A 1000kg

    B 1000kg

    C 1000kg

    D 1000kg

    E 1000kg

    Definition of Soil Types:

    Type A : Loose sand such as dunal sand. Uncompacted site filling may also be included in this soil type.

    Type B : Medium to stiff clays or silty clays

    Type C: Moderately compact sand or gravel eg. of alluvial origin.

    Type D : Compact sand and gravel eg. Weathered sandstone or compacted quarry rubble hardstand

    Type E : Concrete slab on ground. Number of dyna bolts and slab thickness to be designed.

    mailto:[email protected]://www.civilandstructural.com.au/

  • Civil & Structural Engineering Design Services Pty. Ltd.

    23 | P a g e ABN: 62 051 307 852 3 Wanniti Road BELROSE NSW 2085 Tel: 02 9975 3899 Fax: 02 99751943

    Email: [email protected] Web: www.civilandstructural.com.au

    8 Appendix B – Hold Down Method Details

    mailto:[email protected]://www.civilandstructural.com.au/