NETWORK SWITCH BRUCE ELLMAN THEATRE SOUND [email protected] THIS DOCUMENT AND THE SPECIFICATIONS DESCRIBED WITHIN ARE THE EXCLUSIVE PROPERTY OF BRUCE ELLMAN THEATRE SOUND; ISSUED IN THE STRICTEST CONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED WITHOUT THE PRIOR WRITTEN PERMISSION OF BRUCE ELLMAN THEATRE SOUND HAUNTED HOTEL 2014 New York City College of Technology Voorhees Hall 186 Jay Street, Brooklyn NY HAUNTED HOTEL DANTE BLOCK DIAGRAM Exhibit Design: Norma Lee Chartoff Sound Design: Bruce Ellman SIZE DATE DWG NO REV D 8/28/2014 100 - NETWORK BLOCK SCALE 1 : 1 SHEET 1 of 11 Drafted by: Contract with TheatreWorks MAC TOWER COMPUTER RJ45 RJ45 QLAB COMPUTER (“B”) RACK “A” UL ELECTRICS ROOM NOTE: See network diagram for wiring / VLAN details Full Name Three-Letter Code Ranting Brothers Midway MWY Service Entrance SET Cellar Steps CST O'Skully's Wharf OWF Kitchen Prep KPP Service Hall SHL Scullery SLY Boiler BLR Numbered Suites NSS Foyer FYR Coat Check CCK Dining Chamber DCH Tipsy's Parlour TPR Suite 13 S13 Washroom WRM Cranny CNY Conservatory CON Check Out COT Patchen's Picture Palace PPP Cold Storage CSG Elevator ELV Technical Areas: Central Service Area CSA Sound Booth SBT Grid Room GRM USL Room ULR Light Booth LBT Catwalk 1 CW1 Catwalk 2 CW2 Catwalk 3 CW3 Dimmer Room DRM Room 14 V14 Room 13 V13 Audience Area (House) AAH Dressing Room DRM Speaker SPKR-nn Camera CAM-nn Microphone MIC-nn Motion Detector MOTDETC-nn Magnetic Sensor MAGSENSR-nn Photo Sensor PHOTSENS-nn Amp Rack AMPRACK-a SFX Rack SFXRACK-a TCP-I-O Box TCPIO-a Relay Box RELAY-a MechFX MechFX-nn SPLTRACK-01 Split Rack Cable Types XLR EN3 Speakon Coax/Power Cat5 XGA Mechanical Haunted Hotel Code Key Updated May 8, 2014 Device Types (where n equals unique numeric ID, a= alpha ID) DANTE VLAN SHOW CONTROL VLAN USB OMNI 9 OMNI 10 OMNI 11 OMNI 12 OMNI 1 OMNI 2 OMNI 3 OMNI 4 OMNI 5 OMNI 6 OMNI 7 OMNI 8 AES In Out FOH CONSOLE 1 S1-1 2 S1-2 7 S1-7 8 S1-8 5 S1-5 6 S1-6 3 S1-3 4 S1-4 9 S1-9 10 S1-10 11 S1-11 12 S1-12 13 S1-13 14 S1-14 15 S1-15 16 S1-16 YAMAHA DM1000 MIDI In Out Thru SLOT 2 MY16-AT In Out In Out SLOT 1 Dante-MY16-AUD Primary Secondary Ro8-D / 1 out 1 2 3 4 5 6 7 8 DANTE P DANTE S Ro8-D / 2 out 1 2 3 4 5 6 7 8 DANTE P DANTE S Ro8-D / 3 out 1 2 3 4 5 6 7 8 DANTE P DANTE S Ri8-D / 6 In 1 2 3 4 5 6 7 8 DANTE P DANTE S RACK “D” ONSTAGE CONSERVATORY AMP RACK “B” - ROOM V014 (SEE DETAIL ON RACK DRAWINGS) DANTE PRIMARY SWITCH Ro8-D / 4 out 1 2 3 4 5 6 7 8 DANTE P DANTE S Ro8-D / 5 out 1 2 3 4 5 6 7 8 DANTE P DANTE S MAC TOWER COMPUTER RJ45 RJ45 QLAB COMPUTER (“A”) NOTE: STANDBY COMPUTER “B” NIC 1 (SHOW CONTROL) HAS THE SAME IP ADDRESS AS COMPUTER “A” NIC 1 NIC 2 IS USED FOR DANTE VSC NETWORK. ALTERNATE DANTE ROUTING FOR COMPUTER “B” MUST BE ASSIGNED IN THE CONTROLLER. NETWORK SWITCH NOTE: Set the Ri8-D dip-switches to “Daisy-Chain”

City Tech Haunted Hotel Audiobruceellmanportfolio.businesscatalyst.com/assets/haunted... · Motion Detector MOTDETC-nn Magnetic Sensor MAGSENSR-nn Photo Sensor PHOTSENS-nn Amp Rack

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • TM

    Bay Stack 5510-48T Switch

    RPSU

    Pwr Status Up

    Base Down

    Link/Ac t

    In Use

    Console

    Link/Ac t

    In Use

    47 482 4 6 8 10 12

    1 3 5 7 9 11

    14 16 18 20 22 24

    13 15 17 19 21 23

    26 28 30 32 34 36

    25 27 29 31 33 35 Link/Act

    38 40 42 44 46 48

    37 39 41 43 45 47

    Link/Act

    Speed

    Speed

    NETWORK SWITCH

    BRUCE ELLMAN THEATRE SOUND

    [email protected]

    THIS DOCUMENT AND THE

    SPECIFICATIONS DESCRIBED WITHIN ARE

    THE EXCLUSIVE PROPERTY OF BRUCE

    ELLMAN THEATRE SOUND; ISSUED IN THE

    STRICTEST CONFIDENCE AND SHALL NOT

    BE REPRODUCED, COPIED, OR USED

    WITHOUT THE PRIOR WRITTEN

    PERMISSION OF BRUCE ELLMAN THEATRE

    SOUND

    HAUNTED HOTEL 2014New York City College of Technology

    Voorhees Hall186 Jay Street, Brooklyn NY

    HAUNTED HOTEL

    DANTE BLOCK DIAGRAM

    Exhibit Design: Norma Lee Chartoff

    Sound Design: Bruce Ellman

    SIZE DATE DWG NO REV

    D 8/28/2014 100 - NETWORK BLOCK

    SCALE 1 : 1 SHEET 1 of 11Drafted by:

    Contract with TheatreWorks

    MAC TOWER

    COMPUTER

    RJ45

    RJ45

    QLAB

    COMPUTER (“B”)

    RACK “A” UL ELECTRICS ROOM

    NOTE:

    See network diagram for wiring /

    VLAN details

    Full Name Three-Letter Code

    Ranting Brothers Midway MWY

    Service Entrance SET

    Cellar Steps CST

    O'Skully's Wharf OWF

    Kitchen Prep KPP

    Service Hall SHL

    Scullery SLY

    Boiler BLR

    Numbered Suites NSS

    Foyer FYR

    Coat Check CCK

    Dining Chamber DCH

    Tipsy's Parlour TPR

    Suite 13 S13

    Washroom WRM

    Cranny CNY

    Conservatory CON

    Check Out COT

    Patchen's Picture Palace PPP

    Cold Storage CSG

    Elevator ELV

    Technical Areas:

    Central Service Area CSA

    Sound Booth SBT

    Grid Room GRM

    USL Room ULR

    Light Booth LBT

    Catwalk 1 CW1

    Catwalk 2 CW2

    Catwalk 3 CW3

    Dimmer Room DRM

    Room 14 V14

    Room 13 V13

    Audience Area (House) AAH

    Dressing Room DRM

    Speaker SPKR-nn

    Camera CAM-nn

    Microphone MIC-nn

    Motion Detector MOTDETC-nn

    Magnetic Sensor MAGSENSR-nn

    Photo Sensor PHOTSENS-nn

    Amp Rack AMPRACK-a

    SFX Rack SFXRACK-a

    TCP-I-O Box TCPIO-a

    Relay Box RELAY-a

    MechFX MechFX-nn

    SPLTRACK-01 Split Rack

    Cable Types

    XLR EN3

    Speakon

    Coax/Power

    Cat5

    XGA

    Mechanical

    Haunted Hotel Code Key

    Updated May 8, 2014

    Device Types (where n equals unique numeric ID, a= alpha ID)

    DANTE VLANSHOW CONTROL

    VLAN

    USB

    OMNI 9

    OMNI 10

    OMNI 11

    OMNI 12

    OMNI 1

    OMNI 2

    OMNI 3

    OMNI 4

    OMNI 5

    OMNI 6

    OMNI 7

    OMNI 8

    AES

    In Out

    FOH CONSOLE

    1 S1-1

    2 S1-2

    7 S1-7

    8 S1-8

    5 S1-5

    6 S1-6

    3 S1-3

    4 S1-4

    9 S1-9

    10 S1-10

    11 S1-11

    12 S1-12

    13 S1-13

    14 S1-14

    15 S1-15

    16 S1-16

    YAMAHA DM1000

    MIDIIn OutThru

    SLOT 2MY16-AT

    In Out

    In Out

    SLOT 1Dante-MY16-AUD

    Primary

    Secondary

    Ro8-D / 1 out

    1

    2

    3

    4

    5

    6

    7

    8

    DANTE P

    DANTE S

    Ro8-D / 2 out

    1

    2

    3

    4

    5

    6

    7

    8

    DANTE P

    DANTE S

    Ro8-D / 3 out

    1

    2

    3

    4

    5

    6

    7

    8

    DANTE P

    DANTE S

    Ri8-D / 6In

    1

    2

    3

    4

    5

    6

    7

    8

    DANTE P

    DANTE S

    RACK “D” ONSTAGE CONSERVATORY

    AMP RACK “B” - ROOM V014(SEE DETAIL ON RACK DRAWINGS)

    TM

    Bay Stack 5510-48T Switch

    RPSU

    Pwr Status Up

    Base Down

    Link/Ac t

    In Use

    Console

    Link/Ac t

    In Use

    47 482 4 6 8 10 12

    1 3 5 7 9 11

    14 16 18 20 22 24

    13 15 17 19 21 23

    26 28 30 32 34 36

    25 27 29 31 33 35 Link/Act

    38 40 42 44 46 48

    37 39 41 43 45 47

    Link/Act

    Speed

    Speed

    DANTE PRIMARY

    SWITCH

    Ro8-D / 4 out

    1

    2

    3

    4

    5

    6

    7

    8

    DANTE P

    DANTE S

    Ro8-D / 5 out

    1

    2

    3

    4

    5

    6

    7

    8

    DANTE P

    DANTE S

    MAC TOWER

    COMPUTER

    RJ45

    RJ45

    QLAB

    COMPUTER (“A”)

    NOTE:

    STANDBY COMPUTER “B” NIC

    1 (SHOW CONTROL) HAS THE

    SAME IP ADDRESS AS

    COMPUTER “A” NIC 1

    NIC 2 IS USED FOR DANTE

    VSC NETWORK. ALTERNATE

    DANTE ROUTING FOR

    COMPUTER “B” MUST BE

    ASSIGNED IN THE

    CONTROLLER.

    TM

    Bay Stack 5510-48T Switch

    RPSU

    Pwr Status Up

    Base Down

    Link/Ac t

    In Use

    Console

    Link/Ac t

    In Use

    47 482 4 6 8 10 12

    1 3 5 7 9 11

    14 16 18 20 22 24

    13 15 17 19 21 23

    26 28 30 32 34 36

    25 27 29 31 33 35 Link/Act

    38 40 42 44 46 48

    37 39 41 43 45 47

    Link/Act

    Speed

    Speed

    NETWORK SWITCH

    NOTE:

    Set the Ri8-D dip-switches to

    “Daisy-Chain”

  • XLR

    BRUCE ELLMAN THEATRE SOUND

    [email protected]

    THIS DOCUMENT AND THE

    SPECIFICATIONS DESCRIBED WITHIN ARE

    THE EXCLUSIVE PROPERTY OF BRUCE

    ELLMAN THEATRE SOUND; ISSUED IN THE

    STRICTEST CONFIDENCE AND SHALL NOT

    BE REPRODUCED, COPIED, OR USED

    WITHOUT THE PRIOR WRITTEN

    PERMISSION OF BRUCE ELLMAN THEATRE

    SOUND

    HAUNTED HOTEL 2014New York City College of Technology

    Voorhees Hall186 Jay Street, Brooklyn NY

    HAUNTED HOTEL

    SYSTEM BLOCK 1

    UPPER LEVEL

    Exhibit Design: Norma Lee Chartoff

    Sound Design: Bruce Ellman

    SIZE DATE DWG NO REV

    D 8/28/2014 101 - SYSTEM BLOCK DIAGRAM 1

    SCALE 1 : 1 SHEET 2 of 11Drafted by:

    Contract with TheatreWorks

    PWRCN

    PWR

    TM

    Bay Stack 5510-48T Switch

    RPSU

    Pwr Status Up

    Base Down

    Link/Ac t

    In Use

    Console

    Link/Ac t

    In Use

    47 482 4 6 8 10 12

    1 3 5 7 9 11

    14 16 18 20 22 24

    13 15 17 19 21 23

    26 28 30 32 34 36

    25 27 29 31 33 35 Link/Act

    38 40 42 44 46 48

    37 39 41 43 45 47

    Link/Act

    Speed

    Speed

    DANTE PRIMARY

    SWITCH

    FROM SHOW-CONTROL

    (MIDI)

    1

    SECURITY/PCDI

    1

    22

    OutIn

    SECURITY 2

    1

    SECURITY/PCDI

    1

    22

    OutIn

    SECURITY 1

    3 LETTER LOCATION CODE

    SPEAKER NO.

    MODEL

    POSITION

    en3.gif

    AAHSPKR-01UPM-1P (2)

    PWRCN

    PWR

    AAHSPKR-02UPM-1P (3)

    PWRCN

    PWR

    Full Name Three-Letter Code

    Ranting Brothers Midway MWY

    Service Entrance SET

    Cellar Steps CST

    O'Skully's Wharf OWF

    Kitchen Prep KPP

    Service Hall SHL

    Scullery SLY

    Boiler BLR

    Numbered Suites NSS

    Foyer FYR

    Coat Check CCK

    Dining Chamber DCH

    Tipsy's Parlour TPR

    Suite 13 S13

    Washroom WRM

    Cranny CNY

    Conservatory CON

    Check Out COT

    Patchen's Picture Palace PPP

    Cold Storage CSG

    Elevator ELV

    Technical Areas:

    Central Service Area CSA

    Sound Booth SBT

    Grid Room GRM

    USL Room ULR

    Light Booth LBT

    Catwalk 1 CW1

    Catwalk 2 CW2

    Catwalk 3 CW3

    Dimmer Room DRM

    Room 14 V14

    Room 13 V13

    Audience Area (House) AAH

    Dressing Room DRM

    Speaker SPKR-nn

    Camera CAM-nn

    Microphone MIC-nn

    Motion Detector MOTDETC-nn

    Magnetic Sensor MAGSENSR-nn

    Photo Sensor PHOTSENS-nn

    Amp Rack AMPRACK-a

    SFX Rack SFXRACK-a

    TCP-I-O Box TCPIO-a

    Relay Box RELAY-a

    MechFX MechFX-nn

    SPLTRACK-01 Split Rack

    Cable Types

    XLR EN3

    Speakon

    Coax/Power

    Cat5

    XGA

    Mechanical

    Haunted Hotel Code Key

    Updated May 8, 2014

    Device Types (where n equals unique numeric ID, a= alpha ID)

    USB

    OMNI 9

    OMNI 10

    OMNI 11

    OMNI 12

    OMNI 1

    OMNI 2

    OMNI 3

    OMNI 4

    OMNI 5

    OMNI 6

    OMNI 7

    OMNI 8

    AES IN

    In Out

    FOH CONSOLE

    AES OUT

    1 AN-1

    2 SL1-1

    7 S1-7

    8 S1-8

    5 S1-4

    6 S1-5

    3 SL1-2

    4 SL1-3

    9 AN-9

    10 AN-10

    11 S1-11

    12 S1-12

    13 S1-13

    14 AN-16

    15 AN-16

    16 AN-16

    YAMAHA DM1000

    MIDIInOut

    Thru

    SLOT 2EMPTY

    In Out

    In Out

    SLOT 1Dante-MY16-AUD

    Primary

    Secondary

    U1010-1

    XLR

    AMP 1

    DCHSPKR-03UPM-1P (1)

    DCHSPKR-01Bullet (1)

    DCHSPKR-02Bullet (2)

    S13SPKR-01JF-50 (1)

    WRMSPKR-01JF-60 (1)

    TPRSPKR-01MIN-7 (1)

    TPRSPKR-02JF-60 (2)

    CNYSPKR-01SB-120 (1)

    AMP RACK “A” - USL MACHINE ROOM(SEE DETAIL ON RACK DRAWINGS)

    SpeakOn

    U1010-2

    U1010-3

    K1-1

    CCK(BEAR)SPKR-01MIN-7 (2) ELEVATOR WILL REPLACE BEAR IN 2015!!!

    AMP 2

    AMP 3

    CNYSPKR-02JF-80 (1)

    AMP 4

    CONSPKR-01VID-1MM4XPD (1)

    CONSPKR-02VID-2MM4XPD (2)

    CONSPKR-05MM4XP (1)

    CONSPKR-06MM4XP (2)

    CONSPKR-07UP4XP (3)

    CONSPKR-08UP4XP (4)

    CONSPKR-09MM10 (1)

    K1 (1)

    CONSPKR-10MM4XP (5)

    EN3-F

    EN3-F

    EN3-F

    EN3-F

    EN3-F

    EN3-F

    EN3-F

    EN3-F

    GRDSPKR-01CQ-1 (1)

    PWRCN

    PWR

    Ro8-D / 2 out

    1

    2

    3

    4

    5

    6

    7

    8

    DANTE P

    DANTE S

    EN3-M

    EN3-M

    EN3-M

    EN3-M

    EN3-M

    EN3-M

    EN3-M

    EN3-MXLR

    XLR

    XLR

    XLR

    XLR

    XLR

    XLR

    XLR

    MPS 1In out

    1

    2

    3

    4

    5

    6

    7

    8

    Ro8-D / 3 out

    1

    2

    3

    4

    5

    6

    7

    8

    DANTE P

    DANTE S

    Ri8-D / 1In

    1

    2

    3

    4

    5

    6

    7

    8

    DANTE P

    DANTE S

    1

    WATCHOUT/PCDI1

    22

    OutInDINING

    CHAMBER

    1

    WATCHOUT/PCDI

    1

    22

    OutIn

    CONSERVATORYNOTE:

    PLEASE ASSIGN DEVICE NUMBERS TO THE RIO

    UNITS (E.G. “Ri8-D 6” IS SET TO DEVICE “6,” “Ro8-

    D 4” IS SET TO DEVICE “4,” ETC.)

    MPS488e SWITCHES ON BACK SHOULD NOT BE SET TO LINK INPUTS!

    RACK “D” ONSTAGE CONSERVATORY

    Ro8-D / 1 out

    1

    2

    3

    4

    5

    6

    7

    8

    DANTE P

    DANTE S

    MPS 2In out

    1

    2

    3

    4

    5

    ELVSPKR-01CORNER - NMM4XPD (3)

    EN3-F

    ELVSPKR-02CORNER - SMM4XPD (4)

    EN3-F

    ELVSPKR-03CORNER - EMM4XPD (5)

    EN3-F

    ELVSPKR-04CORNER - WMM4XPD (6)

    EN3-F

    ELVSPKR-05SUBMM10 (2)

    EN3-F

    TM

    Bay Stack 5510-48T Switch

    RPSU

    Pwr Status Up

    Base Down

    Link/Ac t

    In Use

    Console

    Link/Ac t

    In Use

    47 482 4 6 8 10 12

    1 3 5 7 9 11

    14 16 18 20 22 24

    13 15 17 19 21 23

    26 28 30 32 34 36

    25 27 29 31 33 35 Link/Act

    38 40 42 44 46 48

    37 39 41 43 45 47

    Link/Act

    Speed

    Speed

    DANTE PRIMARY

    SWITCH

    U1010-4

    MYWSPKR-02SP308A (1)Over Entry Door

    FOH AMP RACK

    AMP 1

    1Paging Mic.

    NOT USED IN

    2014

  • U1010-6

    AMP 1

    AMP RACK “B” - ROOM V014(SEE DETAIL ON RACK DRAWINGS)

    BRUCE ELLMAN THEATRE SOUND

    [email protected]

    THIS DOCUMENT AND THE

    SPECIFICATIONS DESCRIBED WITHIN ARE

    THE EXCLUSIVE PROPERTY OF BRUCE

    ELLMAN THEATRE SOUND; ISSUED IN THE

    STRICTEST CONFIDENCE AND SHALL NOT

    BE REPRODUCED, COPIED, OR USED

    WITHOUT THE PRIOR WRITTEN

    PERMISSION OF BRUCE ELLMAN THEATRE

    SOUND

    HAUNTED HOTEL 2014New York City College of Technology

    Voorhees Hall186 Jay Street, Brooklyn NY

    HAUNTED HOTEL

    SYSTEM BLOCK 2

    LOWER LEVEL

    Exhibit Design: Norma Lee Chartoff

    Sound Design: Bruce Ellman

    SIZE DATE DWG NO REV

    D 8/28/2014 102 - SYSTEM BLOCK DIAGRAM 2

    SCALE 1 : 1 SHEET 3 of 11Drafted by:

    Contract with TheatreWorks

    PWRCN

    PWR

    PWRCN

    PWR

    AMP 2

    Full Name Three-Letter Code

    Ranting Brothers Midway MWY

    Service Entrance SET

    Cellar Steps CST

    O'Skully's Wharf OWF

    Kitchen Prep KPP

    Service Hall SHL

    Scullery SLY

    Boiler BLR

    Numbered Suites NSS

    Foyer FYR

    Coat Check CCK

    Dining Chamber DCH

    Tipsy's Parlour TPR

    Suite 13 S13

    Washroom WRM

    Cranny CNY

    Conservatory CON

    Check Out COT

    Patchen's Picture Palace PPP

    Cold Storage CSG

    Elevator ELV

    Technical Areas:

    Central Service Area CSA

    Sound Booth SBT

    Grid Room GRM

    USL Room ULR

    Light Booth LBT

    Catwalk 1 CW1

    Catwalk 2 CW2

    Catwalk 3 CW3

    Dimmer Room DRM

    Room 14 V14

    Room 13 V13

    Audience Area (House) AAH

    Dressing Room DRM

    Speaker SPKR-nn

    Camera CAM-nn

    Microphone MIC-nn

    Motion Detector MOTDETC-nn

    Magnetic Sensor MAGSENSR-nn

    Photo Sensor PHOTSENS-nn

    Amp Rack AMPRACK-a

    SFX Rack SFXRACK-a

    TCP-I-O Box TCPIO-a

    Relay Box RELAY-a

    MechFX MechFX-nn

    SPLTRACK-01 Split Rack

    Cable Types

    XLR EN3

    Speakon

    Coax/Power

    Cat5

    XGA

    Mechanical

    Haunted Hotel Code Key

    Updated May 8, 2014

    Device Types (where n equals unique numeric ID, a= alpha ID)

    CSTSPKR-01JF-50 (2)

    KPPSPKR-01JF-60 (3)

    NSSSPKR-01JF-60 (4)

    SHLSPKR-01JF60 (7)

    SLYSPKR-01UPA-1P (1)

    CSGSPKR-01UPA-2P (2)

    NSSSPKR-04SP308A (2)

    NSSSPKR-03BULLET (3)

    NSS (RCN 01)SPKR-05JF-60 (6)

    AMP 3

    AMP 4

    TM

    Bay Stack 5510-48T Switch

    RPSU

    Pwr Status Up

    Base Down

    Link/Ac t

    In Use

    Console

    Link/Ac t

    In Use

    47 482 4 6 8 10 12

    1 3 5 7 9 11

    14 16 18 20 22 24

    13 15 17 19 21 23

    26 28 30 32 34 36

    25 27 29 31 33 35 Link/Act

    38 40 42 44 46 48

    37 39 41 43 45 47

    Link/Act

    Speed

    Speed

    DANTE PRIMARY

    SWITCH (2)

    CSTSPKR-02JF-60 (5)

    U1010-7

    K1 (3)

    K1 (4)

    3 LETTER LOCATION CODE

    SPEAKER NO.

    MODEL

    POSITION

    PWRCN

    PWR

    CSGSPKR-02UMS-1P (1)

    BOILER SPEAKER

    PHONE RING / PHONE VOICE

    STRETCHY GUY

    OLD RCN END OF HALL

    SHL BY PIRATE ROOM

    ENTRY SPEAKER – BOTTOM OF STAIRS

    KITCHEN PREP 1

    ENTRY SPEAKER – TOP OF STAIRS

    SCULLERY SPEAKER

    PWRCN

    PWR

    KPPSPKR-02UMS-1P (2)

    KITCHEN PREP 1 SUBWOOFER

    END OF HALL F/X SPEAKER (SUB)

    END OF HALL F/X SPEAKER (FULL RANGE)

    Ro8-D / 4 out

    1

    2

    3

    4

    5

    6

    7

    8

    DANTE P

    DANTE S

    Ro8-D / 5 out

    1

    2

    3

    4

    5

    6

    7

    8

    DANTE P

    DANTE S

  • BRUCE ELLMAN THEATRE SOUND

    [email protected]

    THIS DOCUMENT AND THE

    SPECIFICATIONS DESCRIBED WITHIN ARE

    THE EXCLUSIVE PROPERTY OF BRUCE

    ELLMAN THEATRE SOUND; ISSUED IN THE

    STRICTEST CONFIDENCE AND SHALL NOT

    BE REPRODUCED, COPIED, OR USED

    WITHOUT THE PRIOR WRITTEN

    PERMISSION OF BRUCE ELLMAN THEATRE

    SOUND

    HAUNTED HOTEL 2014New York City College of Technology

    Voorhees Hall186 Jay Street, Brooklyn NY

    HAUNTED HOTEL

    CONSERVATORY SPEAKER

    PLACEMENT

    Exhibit Design: Norma Lee Chartoff

    Sound Design: Bruce Ellman

    SIZE DATE DWG NO REV

    D 8/28/2014 104 - CONSERVATORY SPEAKERS

    SCALE 1/2" = 1'-0" NOT TO SCALE! SHEET 4 of 11Drafted by:

    Contract with TheatreWorks

    MM

    -10

    CONSPKR-01VID-1MM4P (1)

    CONSPKR-05UP4P (1)

    CONSPKR-06MM4P (4)

    CONSPKR-07MM-4P (3)

    CONSPKR-08UP4P (2)

    CONSPKR-09MM10 (1)

    CONSPKR-02VID-2MM4P (2)

    CONSPKR-10MM4P (5)

    Full Name Three-Letter Code

    Ranting Brothers Midway MWY

    Service Entrance SET

    Cellar Steps CST

    O'Skully's Wharf OWF

    Kitchen Prep KPP

    Service Hall SHL

    Scullery SLY

    Boiler BLR

    Numbered Suites NSS

    Foyer FYR

    Coat Check CCK

    Dining Chamber DCH

    Tipsy's Parlour TPR

    Suite 13 S13

    Washroom WRM

    Cranny CNY

    Conservatory CON

    Check Out COT

    Patchen's Picture Palace PPP

    Cold Storage CSG

    Elevator ELV

    Technical Areas:

    Central Service Area CSA

    Sound Booth SBT

    Grid Room GRM

    USL Room ULR

    Light Booth LBT

    Catwalk 1 CW1

    Catwalk 2 CW2

    Catwalk 3 CW3

    Dimmer Room DRM

    Room 14 V14

    Room 13 V13

    Audience Area (House) AAH

    Dressing Room DRM

    Speaker SPKR-nn

    Camera CAM-nn

    Microphone MIC-nn

    Motion Detector MOTDETC-nn

    Magnetic Sensor MAGSENSR-nn

    Photo Sensor PHOTSENS-nn

    Amp Rack AMPRACK-a

    SFX Rack SFXRACK-a

    TCP-I-O Box TCPIO-a

    Relay Box RELAY-a

    MechFX MechFX-nn

    SPLTRACK-01 Split Rack

    Cable Types

    XLR EN3

    Speakon

    Coax/Power

    Cat5

    XGA

    Mechanical

    Haunted Hotel Code Key

    Updated May 8, 2014

    Device Types (where n equals unique numeric ID, a= alpha ID)

  • DCH SPKR-02 – BULLET 2

    DCH SPKR-01 – BULLET 1

    S13 SPKR-01 – JF-50 1

    WRM SPKR-01 – JF-60 1

    TPR SPKR-01 – MIN-7 1

    TPR SPKR-01 – JF-60 2

    CNY SPKR-01 – SB-120 1 CNY SPKR-02 – JF-80 1CST SPKR-01 – JF-50 2

    KPP SPKR-01 – JF-60 3

    NSS SPKR-04 – SP308A 2

    NSS SPKR-01 – JF-60 4

    CST SPKR-02 JF-60 5

    NSS SPKR-03 – BULLET 3

    NSS SPKR-05 – JF-60 6

    SHL SPKR-01 – JF-60 7

    CCK SPKR-01 – MIN-7 2

    BOILER SPEAKER

    RACK B - RM 14 (V14)

    AMP 1 U-1010 (6)

    AMP 4 K-1 (4)

    AMP 3 K-1 (3)

    AMP 2 U-1010 (7)

    NOTE:

    RACKS A, B, AND D ARE CONNECTED

    VIA ETHERNET CABLES

    PLEASE RUN AT LEAST ONE SPARE CAT5E/6 TO EACH

    PHONE RING

    STRETCHY GUY

    BRUCE ELLMAN THEATRE SOUND

    [email protected]

    THIS DOCUMENT AND THE

    SPECIFICATIONS DESCRIBED WITHIN ARE

    THE EXCLUSIVE PROPERTY OF BRUCE

    ELLMAN THEATRE SOUND; ISSUED IN THE

    STRICTEST CONFIDENCE AND SHALL NOT

    BE REPRODUCED, COPIED, OR USED

    WITHOUT THE PRIOR WRITTEN

    PERMISSION OF BRUCE ELLMAN THEATRE

    SOUND

    HAUNTED HOTEL 2014New York City College of Technology

    Voorhees Hall186 Jay Street, Brooklyn NY

    HAUNTED HOTEL

    RACK DRAWINGS

    Exhibit Design: Norma Lee Chartoff

    Sound Design: Bruce Ellman

    SIZE DATE DWG NO REV

    D 8/28/2014 105 - RACK DRAWING

    SCALE 1" = 1'-0" SHEET 5 of 11Drafted by:

    Contract with TheatreWorks

    OLD RCN END OF HALL

    SHL BY PIRATE ROOM

    22 U

    AMP 1 U-1010 (1)

    AMP 2 U-1010 (2)

    AMP 3 U-1010 (3)

    AMP 4 K-1 (1)

    ENTRY SPEAKER – TOP OF STAIRS

    RACK A - USL

    TCP-IO

    NETWORK SWITCH

    FROM AMP CH 1

    MYW SPKR-02 – SP308A 1AMP 1 U-1010 (4)

    RACK “C” FOH RACK

    KITCHEN PREP FULL RANGE

    ENTRY SPEAKER – BOTTOM OF STAIRS

    CON SPKR-01 – MM-4XPD (1)MPS-488HPe (2) OUT 1-8

    NOTE:

    MPS488e SWITCHES ON BACK

    SHOULD BE SET TO NOT LINK

    INPUTS!

    RACK D - ONSTAGECON SPKR-02 – MM-4XPD (2)

    CON SPKR-05 – MM-4XP (1)

    CON SPKR-06 – MM-4XP (2)

    CON SPKR-07 – UP-4XP (1)

    CON SPKR-08 – UP-4XP (2)

    CON SPKR-09 – MM-10 (1)

    CON SPKR-10 – MM-4XP (3)

    Full Name Three-Letter Code

    Ranting Brothers Midway MWY

    Service Entrance SET

    Cellar Steps CST

    O'Skully's Wharf OWF

    Kitchen Prep KPP

    Service Hall SHL

    Scullery SLY

    Boiler BLR

    Numbered Suites NSS

    Foyer FYR

    Coat Check CCK

    Dining Chamber DCH

    Tipsy's Parlour TPR

    Suite 13 S13

    Washroom WRM

    Cranny CNY

    Conservatory CON

    Check Out COT

    Patchen's Picture Palace PPP

    Cold Storage CSG

    Technical Areas:

    Central Service Area CSA

    Sound Booth SBT

    Grid Room GRM

    USL Room ULR

    Light Booth LBT

    Catwalk 1 CW1

    Catwalk 2 CW2

    Catwalk 3 CW3

    Dimmer Room DRM

    Room 14 V14

    Room 13 V13

    Audience Area (House) AAH

    Dressing Room DRM

    Elevator ELV

    Speaker SPKR-nn

    Camera CAM-nn

    Microphone MIC-nn

    Motion Detector MOTDETC-nn

    Magnetic Sensor MAGSENSR-nn

    Photo Sensor PHOTSENS-nn

    Amp Rack AMPRACK-a

    SFX Rack SFXRACK-a

    TCP-I-O Box TCPIO-a

    Relay Box RELAY-a

    MechFX MechFX-nn

    SPLTRACK-01 Split Rack

    Cable Types

    XLR EN3

    Speakon

    Coax/Power

    Cat5

    XGA

    Mechanical

    Haunted Hotel Code Key

    Updated May 8, 2014

    Device Types (where n equals unique numeric ID, a= alpha ID)

    RM-440

    RO8-D 1

    Ro8-D 2

    RO8-D 4

    RO8-D 5

    Ri8-D 1

    Ro8-D 3

    FROM FOH MIXER OMNI 2

    TO AMP CH 1

    NETWORK SWITCH

    NETWORK SWITCH

  • BRUCE ELLMAN THEATRE SOUND

    [email protected]

    THIS DOCUMENT AND THE

    SPECIFICATIONS DESCRIBED WITHIN ARE

    THE EXCLUSIVE PROPERTY OF BRUCE

    ELLMAN THEATRE SOUND; ISSUED IN THE

    STRICTEST CONFIDENCE AND SHALL NOT

    BE REPRODUCED, COPIED, OR USED

    WITHOUT THE PRIOR WRITTEN

    PERMISSION OF BRUCE ELLMAN THEATRE

    SOUND

    HAUNTED HOTEL 2014New York City College of Technology

    Voorhees Hall186 Jay Street, Brooklyn NY

    HAUNTED HOTEL

    DANTE PATCH SCHEDULE

    Exhibit Design: Norma Lee Chartoff

    Sound Design: Bruce Ellman

    SIZE DATE DWG NO REV

    D 8/28/2014 106 - DANTE PATCH SCHEDULE

    SCALE 1" = 1'-0" SHEET 6 of 11Drafted by:

    Contract with TheatreWorks

    Full Name Three-Letter Code

    Ranting Brothers Midway MWY

    Service Entrance SET

    Cellar Steps CST

    O'Skully's Wharf OWF

    Kitchen Prep KPP

    Service Hall SHL

    Scullery SLY

    Boiler BLR

    Numbered Suites NSS

    Foyer FYR

    Coat Check CCK

    Dining Chamber DCH

    Tipsy's Parlour TPR

    Suite 13 S13

    Washroom WRM

    Cranny CNY

    Conservatory CON

    Check Out COT

    Patchen's Picture Palace PPP

    Cold Storage CSG

    Elevator ELV

    Technical Areas:

    Central Service Area CSA

    Sound Booth SBT

    Grid Room GRM

    USL Room ULR

    Light Booth LBT

    Catwalk 1 CW1

    Catwalk 2 CW2

    Catwalk 3 CW3

    Dimmer Room DRM

    Room 14 V14

    Room 13 V13

    Audience Area (House) AAH

    Dressing Room DRM

    Elevator ELV

    Speaker SPKR-nn

    Camera CAM-nn

    Microphone MIC-nn

    Motion Detector MOTDETC-nn

    Magnetic Sensor MAGSENSR-nn

    Photo Sensor PHOTSENS-nn

    Amp Rack AMPRACK-a

    SFX Rack SFXRACK-a

    TCP-I-O Box TCPIO-a

    Relay Box RELAY-a

    MechFX MechFX-nn

    SPLTRACK-01 Split Rack

    Cable Types

    XLR EN3

    Speakon

    Coax/Power

    Cat5

    XGA

    Mechanical

    Haunted Hotel Code Key

    Updated May 8, 2014

    Device Types (where n equals unique numeric ID, a= alpha ID)

    R Ri8-D (WATCHOUT) OUTS 1 2 3 4 5 6 7 8

    D DM1000 DANTE OUT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

    Q QLAB OUT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 56 47 48

    DM1000

    SLOT 1 DANTE CARD 1 Q1

    2 Q2

    3 R1

    4 R2

    5 R3

    6 Q5

    7 Q11

    8 Q12

    9 Q13

    10 Q20

    11 Q26

    12 Q27

    13

    14 Q34

    15

    16 Q36

    Ro8-D 1

    1 D2

    2 Q40

    3 Q41

    4 Q42

    5 Q43

    6 Q44

    7

    8

    Ro8-D 2

    1 Q3

    2 Q4

    3 D3

    4 Q6

    5 Q7

    6 Q8

    7 Q9

    8 Q10

    Ro8-D 3

    1 D4

    2 D5

    3 Q33

    4 D10

    5 Q35

    6 D11

    7 Q37

    8 Q38

    Ro8-D 4

    1 Q17

    2 Q18

    3 Q19

    4 D7

    5 Q21

    6 Q22

    7 Q23

    8 Q15

    Ro8-D 5

    1 Q25

    2 D8 Q26

    3 D9 Q27

    4 Q28

    5

    6

    7

    NOT USED

    IN 2014

  • Full Name Three-Letter Code

    Ranting Brothers Midway MWY

    Service Entrance SET

    Cellar Steps CST

    O'Skully's Wharf OWF

    Kitchen Prep KPP

    Service Hall SHL

    Scullery SLY

    Boiler BLR

    Numbered Suites NSS

    Foyer FYR

    Coat Check CCK

    Dining Chamber DCH

    Tipsy's Parlour TPR

    Suite 13 S13

    Washroom WRM

    Cranny CNY

    Conservatory CON

    Check Out COT

    Patchen's Picture Palace PPP

    Cold Storage CSG

    Elevator ELV

    Technical Areas:

    Central Service Area CSA

    Sound Booth SBT

    Grid Room GRM

    USL Room ULR

    Light Booth LBT

    Catwalk 1 CW1

    Catwalk 2 CW2

    Catwalk 3 CW3

    Dimmer Room DRM

    Room 14 V14

    Room 13 V13

    Audience Area (House) AAH

    Dressing Room DRM

    Speaker SPKR-nn

    Camera CAM-nn

    Microphone MIC-nn

    Motion Detector MOTDETC-nn

    Magnetic Sensor MAGSENSR-nn

    Photo Sensor PHOTSENS-nn

    Amp Rack AMPRACK-a

    SFX Rack SFXRACK-a

    TCP-I-O Box TCPIO-a

    Relay Box RELAY-a

    MechFX MechFX-nn

    SPLTRACK-01 Split Rack

    Cable Types

    XLR EN3

    Speakon

    Coax/Power

    Cat5

    XGA

    Mechanical

    Haunted Hotel Code Key

    Updated May 8, 2014

    Device Types (where n equals unique numeric ID, a= alpha ID)

    THE GRAVESEND INN 2014

    DM1000

    INPATCH CH. NAME SOURCE ASSIGN

    LAYER 1 CH1 PAGE MIC HOUSE AN1 AUX 1 (HOUSE PAGE)

    ANALOG CH2 PAGE MIC LOBBY AN1 AUX 6 (LOBBY PAGE)

    CH3 PAGE MIC BS AN1 BUS 4 (BACKSTAGE PAGE)

    CH4 WATCHOUT DCH S1-03 AUX 2 (DCH)

    CH5 WATCHOUT CON VID 1 S1-04 AUX 4

    CH6 WATCHOUT CON VID 2 S1-05 AUX 5

    CH7

    CH8

    CH9 SEC/PCDI 1 AN9 BUS 7

    CH10 SEC/PCDI 2 AN10 BUS 8

    LAYER 2 CH17 Q1 S1-01 AUX 1 (GRD 1 - HOUSE CQ1)

    DIGITAL CH18 Q2 S1-02 AUX 2 (DCH 3 - DINING CHAMBER UPM-1P)

    CH19 Q5 S1-06 AUX 3 (S13 1 - SUITE 13)

    CH20 Q11 S1-07 AUX 4 (CON 1, VID 1 - MM-4XPD)

    CH21 Q12 S1-08 AUX 5 (CON 2, VID 2 - MM-4XPD)

    CH22 Q13 S1-09 AUX 6 (LOBBY SPEAKER)

    CH23 Q20 S1-10 AUX 7 (CSG 1 - UPA-2P)

    CH24 Q26 S1-11 AUX 8 (NSS-6, SPEAKER NEAR THEATRE ENTRANCE)

    CH25 Q27 S1-12 BUS 1 (SLH SPEAKER NEAR PIRATE ROOM)

    CH26 Q34 S1-13 BUS 2 (CON 6)

    CH27 Q36 S1-14 BUS 3 (CON 8)

    CH28

    CH29

    CH30

    CH31

    CH32

    LAYER 3 CH33 DCH BUS 4 AUX 2

    DIGITAL CH34 S13 BUS 4 AUX 3

    PAGING CH35 VID BUS 4 AUX 4 / 5

    CH36 CSG BUS 4 AUX 7

    CH37 NSS6 BUS 4 AUX 8

    CH38 SLH BUS 4 BUS 1

    CH39

    CH40

    CH41

    CH42

    CH43

    CH44

    CH45

    CH46

    CH47

    CH48

    DM1000

    OUTPATCH SEND TO:

    AUX 1 OMNI 1 GRD-1

    AUX 2 OMNI 2 MWY-1

    AUX 3 S1-02 DCH-3

    AUX 4 S1-04 CSG-01

    AUX 5 S1-11 CON-1

    AUX 6 S1-12 CON-2

    AUX 7 S1-14 CON-6

    AUX 8 S1-15 CON-8

    BUS 1 S1-09 SLH-1

    BUS 2 S1-10 CON-6

    BUS-3 S1-11 CON-8

    BUS-4 LAYER 3 PAGE

    BUS-5 N/A

    BUS-6 N/A

    BUS-7 OMNI 3 AAH-1

    BUS-8 OMNI 4 AAH-2

    NOTES:

    LAYER 1 (INPUTS 1-16):

    1) INPUTS 1-3 ARE ALL ASSIGNED FROM ANALOG IN “1” PAGING MIC.

    2) INPUT 3 (BACKSTAGE PAGING) IS ROUTED TO BUS 4

    3) INPUTS 4-6 ARE WATCHOUT INPUTS FROM SLOT 1 DANTE FEEDS

    4) FEED FROM CONSERVATORY WATCHOUT (BE SURE TO ADJUST MIX LEVEL BETWEEN DIRECT/FILL SPEAKERS CON 1/6 AND CON 2/8

    USING THE APPROPRIATE INPUT CHANNELS— 4 / 5 AND 6 / 7)

    5) INPUTS 9 & 10 ARE ANALOG FROM THE VIDEO SECURITY SYSTEM PCDI’S

    LAYER 2 (INPUTS 17-32):

    1) ALL ARE QLAB / DANTE FEEDS REQUIRING ADDITIONAL ROUTING

    2) ALL ARE AT UNITY GAIN

    LAYER 3 (INPUTS 33-48):

    1) USED TO DIRECT AND SET LEVEL TO BACKSTAGE PAGE SPEAKERS

    2) ALL ARE SOURCED FROM BUS 4

    3) SET LEVELS FOR INDIVIDUAL BACKSTAGE SPEAKERS ON LAYER 3 AND SET OVERALL

    LEVEL ON LAYER 1, INPUT 3

    BRUCE ELLMAN THEATRE SOUND

    [email protected]

    THIS DOCUMENT AND THE

    SPECIFICATIONS DESCRIBED WITHIN ARE

    THE EXCLUSIVE PROPERTY OF BRUCE

    ELLMAN THEATRE SOUND; ISSUED IN THE

    STRICTEST CONFIDENCE AND SHALL NOT

    BE REPRODUCED, COPIED, OR USED

    WITHOUT THE PRIOR WRITTEN

    PERMISSION OF BRUCE ELLMAN THEATRE

    SOUND

    HAUNTED HOTEL 2014New York City College of Technology

    Voorhees Hall186 Jay Street, Brooklyn NY

    HAUNTED HOTEL

    MIXER PATCH SCHEDULE

    Exhibit Design: Norma Lee Chartoff

    Sound Design: Bruce Ellman

    SIZE DATE DWG NO REV

    D 8/28/2014 106A - DM1000 PATCH

    SCALE 1" = 1'-0" SHEET 7 of 11Drafted by:

    Contract with TheatreWorks

  • BRUCE ELLMAN THEATRE SOUND

    [email protected]

    THIS DOCUMENT AND THE SPECIFICATIONS

    DESCRIBED WITHIN ARE THE EXCLUSIVE

    PROPERTY OF BRUCE ELLMAN THEATRE

    SOUND; ISSUED IN THE STRICTEST

    CONFIDENCE AND SHALL NOT BE

    REPRODUCED, COPIED, OR USED WITHOUT

    THE PRIOR WRITTEN PERMISSION OF

    BRUCE ELLMAN THEATRE SOUND

    HAUNTED HOTEL 2014New York City College of Technology

    Voorhees Hall186 Jay Street, Brooklyn NY

    HAUNTED HOTEL

    SIGNAL FLOW

    Exhibit Design: Norma Lee Chartoff

    Sound Design: Bruce Ellman

    SIZE DATE DWG NO REV

    D 8/28/2014 106B - SIGNAL FLOW

    SCALE 1/4" = 1'-

    0"SHEET 8 of 11Drafted by:

    Contract with TheatreWorks

    NOT TO SCALE

    Full Name Three-Letter Code

    Ranting Brothers Midway MWY

    Service Entrance SET

    Cellar Steps CST

    O'Skully's Wharf OWF

    Kitchen Prep KPP

    Service Hall SHL

    Scullery SLY

    Boiler BLR

    Numbered Suites NSS

    Foyer FYR

    Coat Check CCK

    Dining Chamber DCH

    Tipsy's Parlour TPR

    Suite 13 S13

    Washroom WRM

    Cranny CNY

    Conservatory CON

    Check Out COT

    Patchen's Picture Palace PPP

    Cold Storage CSG

    Elevator ELV

    Technical Areas:

    Central Service Area CSA

    Sound Booth SBT

    Grid Room GRM

    USL Room ULR

    Light Booth LBT

    Catwalk 1 CW1

    Catwalk 2 CW2

    Catwalk 3 CW3

    Dimmer Room DRM

    Room 14 V14

    Room 13 V13

    Audience Area (House) AAH

    Dressing Room DRM

    Speaker SPKR-nn

    Camera CAM-nn

    Microphone MIC-nn

    Motion Detector MOTDETC-nn

    Magnetic Sensor MAGSENSR-nn

    Photo Sensor PHOTSENS-nn

    Amp Rack AMPRACK-a

    SFX Rack SFXRACK-a

    TCP-I-O Box TCPIO-a

    Relay Box RELAY-a

    MechFX MechFX-nn

    SPLTRACK-01 Split Rack

    Cable Types

    XLR EN3

    Speakon

    Coax/Power

    Cat5

    XGA

    Mechanical

    Haunted Hotel Code Key

    Updated May 8, 2014

    Device Types (where n equals unique numeric ID, a= alpha ID)

    QLAB OUT ANALOG SOURCE DESCRIPTIONDM1000 INPUT

    CHANNEL(S)DM1000 IN PATCH DM1000 OUTPATCH ANALOG OUT SPEAKER

    1 - THEATER UNDER SCORE 17 S1-01 AUX 1 - OMNI 1 DM1000 OMNI 1 GRID-01 (CQ-1)

    - MIC HOUSE PAGE 1 ANA1 AUX 1 - OMNI 1 DM1000 OMNI 1 GRID-01 (CQ-1)

    2 - DINING CHAMBOR F/X 18 S1-02 AUX 2 - S1-02 Ro8-D/1 CH 1 DCH-03 (UPM-1P)

    - Ri8-D/6 CH 1 DINING CHAMBOR VIDEO 4 S1-03 AUX 2 - S1-02 Ro8-D/1 CH 1 DCH-03 (UPM-1P)

    - MIC BACKSTAGE PAGE 3 / 33 ANA1 AUX 2 - S1-02 Ro8-D/1 CH 1 DCH-03 (UPM-1P)

    3 - DINING CHAMBOR F/X - - - Ro8-D/2 CH 1 DCH-01 (BULLET)

    4 - DINING CHAMBOR F/X - - - Ro8-D/2 CH 2 DCH-02 (BULLET)

    5 - SUITE 13 F/X 19 S1-06 AUX 3 - S1-03 Ro8-D/2 CH 3 S13-01 (JF-60)

    - MIC BACKSTAGE PAGE 3 / 34 ANA1 AUX 3 - S1-03 Ro8-D/2 CH 3 S13-01 (JF-60)

    6 - WASHROOM - - - Ro8-D/2 CH 4 WRM-01 (JF-60)

    7 - TIPSY'S PARLOR - - - Ro8-D/2 CH 5 TPR-01 (MIN-7)

    8 - TIPSY'S PARLOR - - - Ro8-D/2 CH 6 TPR-02 (JF-60)

    9 - CRANNY - - - Ro8-D/2 CH 7 CNY-01 (SB-120)

    CNY-02 (JF-80)

    10 - CHECK IN (BEAR) - - - Ro8-D/2 CH 8 CCK-01 (MIN-7)

    - SECURITY PCDI AUDITORIUM AUDIO

    FROM SECURITY CAM

    9 ANA9 BUS 7 DM1000 OMNI 3 AAH-01 (UPM-1P)

    - SECURITY PCDI AUDITORIUM AUDIO

    FROM SECURITY CAM

    10 ANA10 BUS 8 DM1000 OMNI 4 AAH-02 (UPM-1P)

    11 - VIDEO F/X LEFT 20 S1-07 AUX 4 - S1-04 Ro8-D/3 CH 1 CON-01 (MM-4XPD)

    12 - VIDEO F/X RIGHT 21 S1-08 AUX 5 - S1-05 Ro8-D/3 CH 2 CON-02 (MM-4XPD)

    - Ri8-D/6 CH2 CONSERVATORY VIDEO

    LEFT CHANNEL

    5 S1-04 AUX 4 - S1-04 Ro8-D/3 CH 1 CON-01 (MM-4XPD)

    - Ri8-D/6 CH3 CONSERVATORY VIDEO

    RIGHT CHANNEL

    6 S1-05 AUX 5 - S1-05 Ro8-D/3 CH 2 CON-02 (MM-4XPD)

    - Ri8-D/6 CH2 CONSERVATORY UP LEFT

    AMBIANCE SPEAKER

    7 S1-04 BUS 2 - S1-13 Ro8-D/3 CH 4 CON-06 (MM-4XP)

    - Ri8-D/6 CH3 CONSERVATORY DOWN

    LEFT AMBIANCE SPEAKER

    8 S1-05 BUS 3 - S1-14 Ro8-D/3 CH 6 CON-08 (UP-4XP)

    - MIC BACKSTAGE PAGE 3 / 35 ANA1 AUX 4 - S1-04

    AUX 5 - S1-05

    Ro8-D/3 CH 1

    Ro8-D/3 CH 2

    CON-01 (MM-4XPD)

    CON-02 (MM-4XPD)

    13 - LOBBY MUSIC (LOBBY) 22 S1-09 AUX 6 - OMNI 2 DM1000 OMNI 2 MYW-02 (SP308A)

    - MIC LOBBY PAGE 2 ANA1 AUX 6 - OMNI 2 DM1000 OMNI 2 MYW-02 (SP308A)

    15 - TOP OF STAIRS MUSIC-

    F/X

    - - - Ro8-D/4 CH 8 CST-02 (JF-60)

    17 - BOTTOM OF STAIRS

    MUSIC - F/X

    - - - Ro8-D/4 CH 1 CST-01 (JF-60)

    18 - KITCHEN PREP FULL

    RANGE

    - - - Ro8-D/4 CH 2 KPP-01 (JF-80)

    19 - SCULLERY - - - Ro8-D/4 CH 3 SLY-01 (UPA-1P)

    20 - COLD STORAGE FULL

    RANGE

    23 S1-10 AUX 7 - S1-07 Ro8-D/4 CH 4 CSG-01 (UPA-2P)

    - MIC BACKSTAGE PAGE 3/36 ANA1 AUX 7 - S1-07 Ro8-D/4 CH 4 CSG-01 (UPA-2P)

    21 - COLD STORAGE SUB - - - Ro8-D/4 CH 5 CSG-02 (UMS-1P)

    22 - BOILER SPEAKER - - - Ro8-D/4 CH 6 NSS-04 (SP308A)

    23 - STRETCHY GUY - - - Ro8-D/4 CH 7 NSS-01 (JF-60)

    25 PHONE - - - Ro8-D/5 CH 1 NSS-03 (BULLET)

    26 - RECEPTION(THEATRE

    ENTRANCE

    24 S1-11 AUX 8 - S1-08 Ro8-D/5 CH 2 NSS-06 (JF-60)

    - MIC BACKSTAGE PAGE 3/37 ANA1 AUX 8 - S1-08 Ro8-D/5 CH 2 NSS-06 (JF-60)

    27 - OUTSIDE PIRATE ROOM 25 S1-12 BUS 1 - S1-09 Ro8-D/5 CH 3 SHL-01 (JF-60)

    - MIC BACKSTAGE PAGE 3/38 ANA1 BUS 1 - S1-09 Ro8-D/5 CH 3 SHL-01 (JF-60)

    28 - KITCHEN PREP SUB - - - Ro8-D/5 CH 4 KPP-02 (UMS-1P)

    33 - CONSERVATORY UP

    RIGHT AMBIANCE

    SPEAKER

    - - - Ro8-D/3 CH 3 CON-05 (UP-4XP)

    34 - CONSERVATORY UP LEFT

    AMBIANCE SPEAKER

    26 S1-13 BUS 2 - S1-13 Ro8-D/3 CH 4 CON-06 (MM-4XP)

    35 - CONSERVATORY DOWN

    RIGHT AMBIANCE

    SPEAKER

    - - - Ro8-D/3 CH 5 CON-07 (MM-4XP)

    36 - CONSERVATORY DOWN

    LEFT AMBIANCE SPEAKER

    27 S1-14 BUS 3 - S1-14 Ro8-D/3 CH 6 CON-08 (UP-4XP)

    37 - CONSERVATORY SUB - - - Ro8-D/3 CH 7 CON-09 (MM-10P)

    38 - TRASH CAN - - - Ro8-D/3 CH 8 CON-10 (MM-4XP)

  • BRUCE ELLMAN THEATRE SOUND

    [email protected]

    THIS DOCUMENT AND THE SPECIFICATIONS

    DESCRIBED WITHIN ARE THE EXCLUSIVE

    PROPERTY OF BRUCE ELLMAN THEATRE SOUND;

    ISSUED IN THE STRICTEST CONFIDENCE AND SHALL

    NOT BE REPRODUCED, COPIED, OR USED WITHOUT

    THE PRIOR WRITTEN PERMISSION OF BRUCE

    ELLMAN THEATRE SOUND

    HAUNTED HOTEL 2014New York City College of Technology

    Voorhees Hall186 Jay Street, Brooklyn NY

    HAUNTED HOTEL

    KITCHEN PREP SPEAKER

    PLACEMENT

    Exhibit Design: Norma Lee Chartoff

    Sound Design: Bruce Ellman

    SIZE DATE DWG NO REV

    D 8/28/2014 107 - KITCHEN PREP SPEAKERS

    SCALE 1/2" = 1'-0" NOT TO SCALE! SHEET 9 of 11Drafted by:

    Contract with TheatreWorks

    KPPSPKR-01JF60

    Full Name Three-Letter Code

    Ranting Brothers Midway MWY

    Service Entrance SET

    Cellar Steps CST

    O'Skully's Wharf OWF

    Kitchen Prep KPP

    Service Hall SHL

    Scullery SLY

    Boiler BLR

    Numbered Suites NSS

    Foyer FYR

    Coat Check CCK

    Dining Chamber DCH

    Tipsy's Parlour TPR

    Suite 13 S13

    Washroom WRM

    Cranny CNY

    Conservatory CON

    Check Out COT

    Patchen's Picture Palace PPP

    Cold Storage CSG

    Elevator ELV

    Technical Areas:

    Central Service Area CSA

    Sound Booth SBT

    Grid Room GRM

    USL Room ULR

    Light Booth LBT

    Catwalk 1 CW1

    Catwalk 2 CW2

    Catwalk 3 CW3

    Dimmer Room DRM

    Room 14 V14

    Room 13 V13

    Audience Area (House) AAH

    Dressing Room DRM

    Speaker SPKR-nn

    Camera CAM-nn

    Microphone MIC-nn

    Motion Detector MOTDETC-nn

    Magnetic Sensor MAGSENSR-nn

    Photo Sensor PHOTSENS-nn

    Amp Rack AMPRACK-a

    SFX Rack SFXRACK-a

    TCP-I-O Box TCPIO-a

    Relay Box RELAY-a

    MechFX MechFX-nn

    SPLTRACK-01 Split Rack

    Cable Types

    XLR EN3

    Speakon

    Coax/Power

    Cat5

    XGA

    Mechanical

    Haunted Hotel Code Key

    Updated May 8, 2014

    Device Types (where n equals unique numeric ID, a= alpha ID)

    ums

    UMS-1P HIDDEN

    BEHIND FLAT

    JF60 BEHIND

    PERFORATED

    SECTION OF

    FLAT

    JF60 BEHIND

    PERFORATED

    SECTION OF

    FLAT

    KPPSPKR-02UMS-1P

    KPPSPKR-02UMS-1P

    KPPSPKR-01JF60

    UMS-1P HIDDEN

    BEHIND FLAT

  • UPM 1P IDEAL

    POSITIONS

    CATWALK 10'

    OFF CENTER

    UPM 1P

    ALTERNATE

    POSITIONS OFF

    CENTER OF

    CATWALK

    UPM 1P IDEAL

    POSITIONS

    CATWALK 10'

    OFF CENTER

    ALTERNATE

    POSITIONPREFERRED

    POSITION

    PREFERRED

    POSITION

    BRUCE ELLMAN THEATRE SOUND

    [email protected]

    THIS DOCUMENT AND THE SPECIFICATIONS

    DESCRIBED WITHIN ARE THE EXCLUSIVE PROPERTY

    OF BRUCE ELLMAN THEATRE SOUND; ISSUED IN THE

    STRICTEST CONFIDENCE AND SHALL NOT BE

    REPRODUCED, COPIED, OR USED WITHOUT THE

    PRIOR WRITTEN PERMISSION OF BRUCE ELLMAN

    THEATRE SOUND

    HAUNTED HOTEL 2014New York City College of Technology

    Voorhees Hall186 Jay Street, Brooklyn NY

    HAUNTED HOTEL

    AUDIENCE AREA SPEAKERS

    Exhibit Design: Norma Lee Chartoff

    Sound Design: Bruce Ellman

    SIZE DATE DWG NO REV

    D 8/28/2014 108 - AUDIENCE AREA SPEAKERS

    SCALE 1/4" = 1'-0" SHEET 10 of 11Drafted by:

    Contract with TheatreWorks

    NOT TO SCALE

    Full Name Three-Letter Code

    Ranting Brothers Midway MWY

    Service Entrance SET

    Cellar Steps CST

    O'Skully's Wharf OWF

    Kitchen Prep KPP

    Service Hall SHL

    Scullery SLY

    Boiler BLR

    Numbered Suites NSS

    Foyer FYR

    Coat Check CCK

    Dining Chamber DCH

    Tipsy's Parlour TPR

    Suite 13 S13

    Washroom WRM

    Cranny CNY

    Conservatory CON

    Check Out COT

    Patchen's Picture Palace PPP

    Cold Storage CSG

    Elevator ELV

    Technical Areas:

    Central Service Area CSA

    Sound Booth SBT

    Grid Room GRM

    USL Room ULR

    Light Booth LBT

    Catwalk 1 CW1

    Catwalk 2 CW2

    Catwalk 3 CW3

    Dimmer Room DRM

    Room 14 V14

    Room 13 V13

    Audience Area (House) AAH

    Dressing Room DRM

    Speaker SPKR-nn

    Camera CAM-nn

    Microphone MIC-nn

    Motion Detector MOTDETC-nn

    Magnetic Sensor MAGSENSR-nn

    Photo Sensor PHOTSENS-nn

    Amp Rack AMPRACK-a

    SFX Rack SFXRACK-a

    TCP-I-O Box TCPIO-a

    Relay Box RELAY-a

    MechFX MechFX-nn

    SPLTRACK-01 Split Rack

    Cable Types

    XLR EN3

    Speakon

    Coax/Power

    Cat5

    XGA

    Mechanical

    Haunted Hotel Code Key

    Updated May 8, 2014

    Device Types (where n equals unique numeric ID, a= alpha ID)

  • BRUCE ELLMAN THEATRE SOUND

    [email protected]

    THIS DOCUMENT AND THE

    SPECIFICATIONS DESCRIBED WITHIN ARE

    THE EXCLUSIVE PROPERTY OF BRUCE

    ELLMAN THEATRE SOUND; ISSUED IN THE

    STRICTEST CONFIDENCE AND SHALL NOT

    BE REPRODUCED, COPIED, OR USED

    WITHOUT THE PRIOR WRITTEN

    PERMISSION OF BRUCE ELLMAN THEATRE

    SOUND

    HAUNTED HOTEL 2014New York City College of Technology

    Voorhees Hall186 Jay Street, Brooklyn NY

    HAUNTED HOTEL

    COMS

    Exhibit Design: Norma Lee Chartoff

    Sound Design: Bruce Ellman

    SIZE DATE DWG NO REV

    D 8/28/2014 200 - COMS

    SCALE 1" = 1'-0" SHEET 11 of 11Drafted by:

    Contract with TheatreWorks

    Full Name Three-Letter Code

    Ranting Brothers Midway MWY

    Service Entrance SET

    Cellar Steps CST

    O'Skully's Wharf OWF

    Kitchen Prep KPP

    Service Hall SHL

    Scullery SLY

    Boiler BLR

    Numbered Suites NSS

    Foyer FYR

    Coat Check CCK

    Dining Chamber DCH

    Tipsy's Parlour TPR

    Suite 13 S13

    Washroom WRM

    Cranny CNY

    Conservatory CON

    Check Out COT

    Patchen's Picture Palace PPP

    Cold Storage CSG

    Elevator ELV

    Technical Areas:

    Central Service Area CSA

    Sound Booth SBT

    Grid Room GRM

    USL Room ULR

    Light Booth LBT

    Catwalk 1 CW1

    Catwalk 2 CW2

    Catwalk 3 CW3

    Dimmer Room DRM

    Room 14 V14

    Room 13 V13

    Audience Area (House) AAH

    Dressing Room DRM

    Speaker SPKR-nn

    Camera CAM-nn

    Microphone MIC-nn

    Motion Detector MOTDETC-nn

    Magnetic Sensor MAGSENSR-nn

    Photo Sensor PHOTSENS-nn

    Amp Rack AMPRACK-a

    SFX Rack SFXRACK-a

    TCP-I-O Box TCPIO-a

    Relay Box RELAY-a

    MechFX MechFX-nn

    SPLTRACK-01 Split Rack

    Cable Types

    XLR EN3

    Speakon

    Coax/Power

    Cat5

    XGA

    Mechanical

    Haunted Hotel Code Key

    Updated May 8, 2014

    Device Types (where n equals unique numeric ID, a= alpha ID) CHAN. 1 OUT

    CHAN. 2 OUT

    CHAN. 3 OUT CHAN A IN

    VID 1 VID 2 VID 3

    RM 440

    AMP RACK “B” - ROOM V014(SEE DETAIL ON RACK DRAWINGS)

    RS 501 RS 501 RS 501

    IN HOUSE VIDEO CONTROL

    LIGHTING BOOTH RACK

    SB 440

    CHAN A IN

    WIRELESS 1

    CHAN A

    WIRELESS 2

    CHAN A

    WIRELESS 4

    CHAN A

    WIRELESS 3

    CHAN A

    V014 BISCUIT

    SM BISCUIT

    LIGHT BOOTH

    KB 211GM

    CHAN. 4 OUT

    CHAN A

    CM 244

    WIRELESS BASE STATION

    WIRED BASE STATION / MATRIX

    NOTE:

    ALL WIRED COMM CONNECTIONS ARE VIA 3-PIN XLR

    HAUNTED HOTEL 2014 DRAWINGS 8-28-14.vsd100 - NETWORK BLOCK101 - SYSTEM BLOCK DIAGRAM 1102 - SYSTEM BLOCK DIAGRAM 2104 - CONSERVATORY SPEAKERS105 - Rack Drawing106 - DANTE PATCH SCHEDULE106A - DM1000 PATCH106B - SIGNAL FLOW107 - Kitchen Prep Speakers108 - Audience Area Speakers200 - COMS