Richard T. Reep Architect2707 Chelsea StreetOrlando, FL 32803
seal
The original sheet size is ARCH D 24" x 36". Copyright Richard T. Reep Architect, All rights reserved. c
Harris Civil EngineersLouis J. McTague LLC1200 Hillcrest Street Suite 200Orlando, FL 32803
www.harriscivilengineers.com407-629-4777EB9814
1121 Hamilton AvenueLongwood, FL 32750
www.ljmctague.com407-834-6840PE56061
Structural Engineer Civil Engineer Architect
BK Williams Engineering LLC333 Emerald Pl WIndian Harbour Beach, FL 32937
www.bkweng.com321-272-3559EE######
Electrical Engineer
6/15/2020 4:08:12 PM
G000
15 June 2020Issued for Bid
City of Winter Springs Central Winds Park - Trailhead Restroom1000 Central Winds DriveWinter Springs, Florida 32708
126 East State Road 434Winter Springs, Florida 32708
A200
A200
A2001A200
3
2
4A500
1
4
3
2 A500
5
8
7
6
1
3
2
1A400 Men's Room
1Women's Room
2
Utility Room3
warp slab as required to be flush with interior finished floor
8' - 0" 25' - 4"
8' -
0"9'
- 4"
8' -
0"
25' -
4"
Ove
rhan
g
Precast cap
4" concrete apron
7' - 4" 8' - 8"
3' -
4 5/
8"
1' - 4" 9' - 4"1' - 4"
Alum columns
Concrete sidewalk
cont
rol j
oint
control joint
EQ EQ EQcont
rol j
oint
cont
rol j
oint
cont
rol j
oint
control joint
control joint control joint
cont
rol j
oint
cont
rol j
oint
Downspout
5' turnaround 5' turnaround
FD FD FD
0' - 4"
cont
rol j
oint
cont
rol j
oint
4' - 0" stainless steel shelfmount at 4' - 6" AFF
mop handle bracketmount at 4' - 0" AFF
Men's Room1
Utility Room3
Women's Room2
Drinking Fountain
For toilet accessories see elevations
For toilet accessories see elevations
Center floor drain in room Center floor drain in room
1' -
5"2'
- 0"
Clearance at power panel
slop
e do
wn
slop
e do
wn
slop
e do
wn
1A400
Slope down 1/4" = 1' - 0"
6" x 6" aluminum Gutter
6" diameter aluminum Downspout
Low aluminum trellis High aluminum trellis
VTR wtih flashing boot
4A400
Exhaust fans
Richard T. Reep Architect2707 Chelsea Street
Orlando, FL [email protected]
407-408-4953AR11827
Civil Engineer
Structural Engineer
The original sheet size is ARCH D 24" x 36". Copyright Richard T. Reep Architect, All rights reserved. c
Electrical Engineer
6/15/2020 4:07:55 PM
A100
Floor Plan,Roof Plan
15 June 2020
Issued for Bid
Cen
tral W
inds
Par
k -
Trai
lhea
d R
estro
om
City
of W
inte
r Spr
ings
1/4" = 1'-0"1 Floor Plan - General 1/4" = 1'-0"3 Roof Plan
Finished Floor0' - 0"
top of low parapet10' - 8"
top of high parapet14' - 0"
1A400
Exposed CMU
Aluminum shade trellis
Knee wall Stacked stone veneer on CMU
Aluminum columns
Precast wall cap
4' -
0"
Stacked stone veneer parapet beyond
Aluminum cornice
Exposed CMU parapet beyond
1' - 4" Exterior light fixtures
Finished Floor0' - 0"
top of low parapet10' - 8"
top of high parapet14' - 0"
Stacked stone veneer on CMU
Downspout
Aluminum Shade trellis
3
Aluminum Shade trellis
Aluminum cornice
Aluminum coping cap
Aluminum cornice
Exposed splitface center scored CMU
Six 2" air gaps at 8' - 0" AFF
8' -
0"
18' - 0" 4' - 0"
4A400
alig
n
Meter
6' - 4" 1' - 4"
Tota
l hei
ght
14' -
0"
Finished Floor0' - 0"
top of low parapet10' - 8"
top of high parapet14' - 0"
Exposed splitface CMU
Downspout beyond
Aluminum shade trellis Aluminum shade trellis
1 2
Drinking fountain
Aluminum coping cap
Aluminum support beam and column
Precast knee wall cap
Stone veneer over CMU
Stone veneer over CMU
4' -
8"
1' - 0"
Aluminum support beam
Aluminum column
Precast knee wall cap
Stone veneer knee wall
Restroom sign typ
4A400
2' -
0" 4' -
0"
alig
n
1' - 0"2' - 0"
Typ exterior lighting
Finished Floor0' - 0"
top of high parapet14' - 0"
west knee wall2' - 0"
1A400
Stone veneer over CMU
Gutter Aluminium shade trellis
Precast knee wall cap
Downspout
Aluminum cornice
Stone veneer over CMU
Aluminum coping cap
Exposed splitface CMU
Six 2" air gaps at 8" o.c. Aluminum support columns
Aluminum support beam
Exposed splitface CMU
1' - 6" 1' - 6"
Exterior light fixtures
1' - 0"
Richard T. Reep Architect2707 Chelsea Street
Orlando, FL [email protected]
407-408-4953AR11827
Civil Engineer
Structural Engineer
The original sheet size is ARCH D 24" x 36". Copyright Richard T. Reep Architect, All rights reserved. c
Electrical Engineer
6/15/2020 4:07:57 PM
A200
Elevations
15 June 2020
Issued for Bid
Cen
tral W
inds
Par
k -
Trai
lhea
d R
estro
om
City
of W
inte
r Spr
ings
1/4" = 1'-0"1 East 1/4" = 1'-0"2 North
1/4" = 1'-0"3 South 1/4" = 1'-0"4 West
Project Specifications
00 – General Conditions• Site Logistics - coordinate site access, materials staging, and hours of operation with Sitework Contractor.• Provide permit box, silt fence as indicated in Package 2, tree protection fencing, portable toilet, temporary power, and temporary water.
02 – Sitework• Site clearing – remove existing vegetation in the required site areas for construction.• Site grading – rough grade site to level indicated on sheet C201. Provide fill as needed to achieve grades as shown.• Utilities: Provide for permanent power and water from local utilities.• Drainage: Site stormwater will be drained to location as indicated on C201.• Driveway and vehicular paving areas: See Package 2.
03 – Concrete• Provide concrete and grout for structural items as indicated and as specified on sheet S100.• Provide concrete for non-structural items to dimensions indicated on drawings. Use 3000psi concrete minimum.
04 – Concrete Masonry Units• Provide 8" x 8" x 16" concrete masonry units conforming to ASTM C90, with all shapes necessary to achieve project, and as specified on sheet S100. • Use ladder ties every 16". Reinforce as indicated on sheet S100.• All CMU shall be natural gray concrete color of uniform color and texture.• Exposed exterior face of block (where not concealed by veneer) shall be scored vertically in the center to create 8" x 8" exterior face module and be splitface.• Mortar shall be Type N, natural gray color.
05 – Metal• Provide structural steel as indicated and as specified on sheet S100.• Provide aluminum to ASTM B 210 Specification for Aluminum and Aluminum Alloy Drawn Seamless Tubes. • Aluminium tube shapes will be coated with fluoropolymer powder conforming to AAMA 2605. All fasteners for use with aluminum shapes shall be aluminum or stainless steel.
06 – Wood• Plywood shall be finish All dimensional lumber to be pressure treated.• Provide structural and nonstructural dimensional lumber and framing as specified on sheet S200.• 07 – Waterproofing• Sealants – Exterior sealants to be compatible with substrate.• Roof – provide membrane roofing equal to GAF Ruberoid granular surface modified bitumen roof membrane with all accessories including primer, flashing, sealants with minimum 10 year labor / 15 year material warranty. Provide coated aluminum flashing shapes and sizes as indicated on plans. Coating color to be selected from manufacturer's standard colors.• Insulation – For roof deck, provide 2" closed-cell polyisocyanurate (polyiso) foam core insulation panels.
08 – Doors• Specification: Basis of design is Cline Aluminum Doorss, Inc. Series 100BE for Doors and Frames. Email [email protected]. Provide urethane foam-filled aluminum door, flush face design, high traffic and high abuse. Door shall meet wind load criteria as indicated on sheet S1.1. Door shall have architectural quality aluminum sheet one-piece smooth face minimum 0.090" thick plain unpatterned. Door shall carry Florida Product Approval number FL6336.• Finish: Door and frame finish shall be factory finish fluoropolymer coating conforming to AAMA 2605 or better.• Frame: extruded channel aluminum components with manufacturer's standard corrosion-resistant, nonstaining, nonmagnetic metal anchors, clips, and accessories, profile Open Back with Applied Stop, 0.125" min thickness extruded shape. Corners shall be cut square with no exposed fasteners. Hinge and strike mounting plates shall be extruded aluminum alloy bar stock. Concealed integral channel. If steel perimeter anchors are used for masonry anchoring, provide coated steel and insulation between steel and aluminum to prevent galvanic action.• Hardware: Hardware shall be as specified on door schedule. • Louver: Where louver occurs, provide louver of extruded aluminum components with manufacturer's standard fasteners. Blades and frames shall have extruded aluminum alloy, with "Y" type louver blades for privacy. Louver shall have 50% minimum free air flow.
09 – Finishes• Exterior, concrete masonry units: After removing effloresence, excess mortar, rust and grease from exterior face of block, apply Copper Sulphate stain to a light hue. Mask areas not to receive sealer (aluminum, signage, etc).• Exterior, concrete masonry units: CMU shall be smooth-faced where Stacked Stone veneer is indicated. Provide Eldorado Stone Stacked Stone Veneer, Black River profile. Prepare 2' x 4' mockup on West Wall at base for review and approval. Contact [email protected].• Interior, floors: Provide polyurethane concrete slurry broadcast floor equal to Ucretre DP Basecoat B6 to 1/8" total thickness of base coat and top coat.ucrete • Interior Coating - Provide low VOC interior coating systems as follows: Concrete Masonry Units: First coat = acrylic high-build masonry block filler. Second coat = Acrylic gloss enamel. Wood: First coat = water-based primer. Second coat = water-based eggshell/satin acrylic latex.
10 – Accessories• Signage - Signage shall be securely affixed to exterior wall per manufacturer's instructions. Restroom signage: PVC raised-letter restroom signage with contrasting color conforming to Florida Building Code - Accessibility for restrooms. Donor Plaque: cast bronze donor plaque minimum 1/8" thickness with raised letters and enamel coated field. Restroom Accessories - Owner will furnish and install accessories marked with asterisk* Grab Bars: brushed stainless steel smooth 1 1/4" diameter with concealed flanges. * Toilet Paper Holders: Stainless Steel lockable jumbo roll, Bobrick B-2890. * Paper Towel Dispenser: Stainless Steel roll-type paper towel dispenser, Bobrick B-2860. * Soap Dispenser: Stainless Steel liquid type dispenser, Bobrick B-4112. P-trap underlav insulator: PVC insulating wrap, Handy-Shield by Plumberex Baby Changing Table: Stainless Steel foldable station, Koala KB200-01SS.
11 through 21 – not used
22 - Plumbing - See P100.
23 - HVAC• Exhaust Fans - Provide low-profile grill 110CFM exhaust fan with duct transition as required for roof cap connection. Provide equivalent to Nutone AERN110K.Blocking as required to support fan in roof structure. Flashing - self-flashing unit as required for low-slope roofs. Roof cap - Roof cap compatible with unit to include backdraft damper and bird screen, equivalent to Broan 634M.
26 - Electrical - See E100.
Interior Walls - Sherwin Williams 6510, "Loyal Blue"
Interior exposed wood deck - Sherwin Williams SW7005, "Pure White"
Exposed center scored splitface CMUCopper Sulphate stain applied min 4 coats to light hue
Exterior metal - Aluminum color powder coated aluminum
Stacked stone veneer - Eldorado "Black River"
7' -
0"
3' - 0"
7' -
0"
3' - 0"
Painted aluminum frame
Painted aluminum door
Painted aluminum louver
Door Type A Door Type B
Concrete slab
Threshold
Door
Frame beyond
E9-0716
Filled cell
Sealant and backer rod
Blocking
Frame
Door
Threshold below
Concrete lintel
Sealant and backer rod
Blocking
Alum frame
Door
Doors: All door shall receive the FL6336 label. Basis of Design is as indicated in Specifications. All door hardware shall be:
Hinges: Exterior hinges to be Ball Bearing Stainless Steel (32D) on out swinging doors furnished with Non-Removable Pins (NRP) Stanley FBB199 or equalClosers: Shall be Corbin Russwin DC6210 (689) OPTIONAL
Locksets: Shall be Grade 1 Heavy Duty Cylindrical Lockset Corbin Russwin CL3500 series with Corbin Russwin Deadlock DL3000
Keying: Determined by City of Winter Springs
Thresholds and Weatherstrip: Shall be as follows: Weatherstrip: Wool Pile (Aluminum Door Mfr.) Threshold: Pemko 520S Door Sweep Pemko 18100CNB Rain Drip Cap, Pemko 346C
Hardware Schedule:
Quantity Description Model Number Finish MFR
3. EA HINGE FBB199NRP 32D STAN 1. EA. LOCKSET CL3510 NZD 626. CR 1 EA. DEADLOCK DL3013 626 CR 1. EA CYLINDER TBA 626 TBA 1. EA. SURFACE CLOSER. DC6210 689. CR. OPTIONAL 1. EA DOOR SWEEP 18100CNB AL PEM 1 EA. RAIN CAP 346C C PEM 1 EA. THRESHOLD 520S AL PEM
Richard T. Reep Architect2707 Chelsea Street
Orlando, FL [email protected]
407-408-4953AR11827
Civil Engineer
Structural Engineer
The original sheet size is ARCH D 24" x 36". Copyright Richard T. Reep Architect, All rights reserved. c
Electrical Engineer
6/15/2020 4:07:59 PM
A300
Schedules andSpecifications
15 June 2020
Issued for Bid
Cen
tral W
inds
Par
k -
Trai
lhea
d R
estro
om
City
of W
inte
r Spr
ings
Door Schedule
DoorNumber Door Type Door Size Frame Type
DetailsDescription
FinishHead Jamb Sill Door Frame Comments
1 A 36" x 84" Aluminum 6/A300 5/A300 4/A300 Aluminum paint paint witih louver2 A 36" x 84" Aluminum 6/A300 5/A300 4/A300 Aluminum paint paint witih louver3 B 36" x 84" Aluminum 6/A300 5/A300 4/A300 Aluminum paint paint -
Room Finish Schedule
RoomNumber
RoomName
FinishCommentsFloor Base Wall Ceiling
1 Men'sRoom
Ucrete Ucrete PaintedCMU
Paintedwood
See color schedule detail 2
2 Women'sRoom
Ucrete Ucrete PaintedCMU
Paintedwood
See color schedule detail 2
3 UtilityRoom
Ucrete Ucrete PaintedCMU
Paintedwood
See color schedule detail 2
1" = 1'-0"1 Architectural Specifications 1" = 1'-0"2 Color Selections
1/4" = 1'-0"3 Door and Frame Elevations
1 1/2" = 1'-0"4 Sill
1 1/2" = 1'-0"5 Jamb
1 1/2" = 1'-0"6 Head 1" = 1'-0"7 Door Hardware
Finished Floor0' - 0"
top of low parapet10' - 8"
top of high parapet14' - 0"
top of interior walls8' - 0"
A4002
Gutter
Downspout
2" x dimensional lumber framing
Low slope roof
A4007
4A400
4' -
6"
4' -
0"
Shelf Mop holder
Insect screen at vent gap
Finished Floor0' - 0"
top of low parapet10' - 8"
Bond beam
8" splitface center scored CMU
Alum coping over 2" x blocking
Counterflashing
1/2" x 1 1/2" alum termination bar w/ 2 1/2" concrete masonry anchors at 12" o.c.
Sealant at top of roof membrane
Roof cover - turn up min. 7"
Structural framing
Concrete sidewalkFloor finish
Base finish
Interior wall finish
Concrete slab
Vapor barrier
Compressed fill
P.T. 2" x 8" top plate with 7 1/2" J-bolt at 2' - 0" o.c. in bond beam
Roof Assembly: granular surface modified bitumen single layer over 3/8" densglas coverboard over 2" polyisocyanurate rigid insulation panels
Structural deck
P. T. 2" x 10" ledger
LUS210 with eight - 10d nails in ledger and four - 10d nails in joist
Stacked stone veneer on standard face 8" CMU
Aluminum 3" x 8" cornice
Flashing cleat
Use height of stacked stone veneer to determine number of courses of standard face CMU and transition to splitface CMU
Light fixture beyond
19' - 0" 4' - 4"
4' -
0"
0' -
11 1
/4"
0' -
11 1
/4"
0' -
11 1
/4"
0' -
11 1
/4"
typ both sides - 3" diameter aluminum columns at 1' - 0" on center under each trellis member
4' - 4" 9' - 0"
4' -
0"
0' -
11 1
/4"
0' -
11 1
/4"
0' -
11 1
/4"
0' -
11 1
/4"
3"x 8" sq alum tube
3" dia round alum tube
Parapet flashing beyond
Turn up roof cover
2" x blocking at end
Aluminum cornice
Aluminum flashing
Aluminum gutter
3/4" plywood
Aluminum downspout
Strap
Stacked stone veneer
8" CMU
End flashing
Roof Assembly: granular surface modified bitumen single layer over 3/8" denslglas coverboard over 2" polyisostyrene rigid insulation panels
Structural roof deck
Roof framing joists
7 1/2" x 1/2" Anchor bolt at 2' - 0" on center
H3 hurricane clip ea roof joist
8" CMU bond beam w/ one #5 continuous
P. T. 2” x 8” bearing plate
Sealant at top of roof membrane
1/2" x 1 1/2" aluminum termination bar with 2 1/2" concrete masonry anchors at 1' - 0" on center
Counterflashing
Sealant at top of counterflashing
stacked stone veneer - north parapet
Turn roof membrane up 7" min
Roof assembly: granular surface modified bitumen over 3/8" densglas coverboard over 2" polyisocyanurate rigid insulation
P. T. wood blocking at edge
Roof framing joist
3" x 8" aluminum tube cornice
Aluminum coping over 2" x blocking
P. T. 2" x 8" top plate with 7" J-bolt at 2' - 0" o.c. in bond beam
Bond beam
Stacked stone veneer on 8" CMU
Stacked stone veneer on 8" CMU
Stacked stone veneer on 8" CMU
Richard T. Reep Architect2707 Chelsea Street
Orlando, FL [email protected]
407-408-4953AR11827
Civil Engineer
Structural Engineer
The original sheet size is ARCH D 24" x 36". Copyright Richard T. Reep Architect, All rights reserved. c
Electrical Engineer
6/15/2020 4:08:01 PM
A400
Sections andDetails
15 June 2020
Issued for Bid
Cen
tral W
inds
Par
k -
Trai
lhea
d R
estro
om
City
of W
inte
r Spr
ings
1/4" = 1'-0"1 Section 1
3/4" = 1'-0"2 Typical wall section
1/2" = 1'-0"6 High Aluminum Trellis
1/2" = 1'-0"5 Low Aluminum Trellis 3 Trellis isometric
1 1/2" = 1'-0"7 Eave detail 1 1/2" = 1'-0"4 High parapet detail
2' - 0"Paper towel dispenser
Soap dispenser
Insulation jacket at drain
8" base
Baby changing table
3' -
6"
EQ EQ
2' -
4 3/
4"
8" base
Baby changing table
Six 2" gaps Painted wood framing
0' - 8"
2' -
11"
Grab bar see 5/G100 for location
Toilet paper dispenser
8" base
1' -
4"
2' - 0"
2' -
11"
3' -
6"
Painted wood framing
Soap dispenser
Paper towel dispenser
8" base
Grab bar - see 5/G100 for location
Toilet paper holder
Paper towel dispenser
Soap dispenser
Insulation jacket at drain
8" base
Baby changing table
3' -
6"
2' - 0"
3' -
6"
Soap Dispenser
Paper towel dispenser Grab bar
Toilet paper dispenser8" base
Painted wood framingSix - 2" gaps
Grab bar - See 5/G100 for location
Toilet paper holder
0' - 8"
1' -
6"
EQ EQ
2' -
4 3/
4" Typ - 8" base
Baby changing table
Richard T. Reep Architect2707 Chelsea Street
Orlando, FL [email protected]
407-408-4953AR11827
Civil Engineer
Structural Engineer
The original sheet size is ARCH D 24" x 36". Copyright Richard T. Reep Architect, All rights reserved. c
Electrical Engineer
6/15/2020 4:08:03 PM
A500
InteriorElevations
15 June 2020
Issued for Bid
Cen
tral W
inds
Par
k -
Trai
lhea
d R
estro
om
City
of W
inte
r Spr
ings
1/4" = 1'-0"1 Room 1 - South 1/4" = 1'-0"2 Room 1 - West
1/4" = 1'-0"3 Room 1 - North 1/4" = 1'-0"4 Room 1 - East
1/4" = 1'-0"5 Room 2 - South 1/4" = 1'-0"6 Room 2 - West
1/4" = 1'-0"7 Room 2 - North 1/4" = 1'-0"8 Room 2 - East
4"
2" vent overhead
4" VTR
2"
2"
1 1/2"
1 1/
2"
1 1/
2"
to sanitary sewerto potable water supply
CO
FD2
P1
P2
FD3
P3
P2
FD2
P1
1 1/
2"
HB
all sanitary sewer lines are under slab except where necessary to connect to fixture
All water supply lines are above slab except to site connection.
4"
CO
sidewalk
1 1/2" up
CO
FD2
FD3
FD2
P1
P3
P2
4" VTR
P1
P2
To sanitary sewer
Finished Floor
4"
4"
4"
4"
4"
2"1 1/2"
2"
2"
2"
2"
slope 1/8" per foot
slope 1/8" per foot
CO
2"
2"2"
2"
2"
Plumbing Specifications
15 – Plumbing• Water supply piping shall be Schedule 40 CPVC, sizes as indicated.
Provide shutoff valve at each fixture P1, P2, and P3. All shutoff valves shall be located within Room 3.Connect water supply to new line at nearest location to potable water utility.
• Sanitary sewer piping shall be schedule 40 PVC, sizes as indicated.Provide cleanouts where shown.Provide vent through roof with flashing boot.Connect sanitary sewer to new sanitary line as indicated on Civil Engineering plans.
• Plumbing fixtures• P2 - Toilet: Kohler "Kingston" 4323 wall-mount 1.28 gpf with rear inlet. Provide seat. Mount toilet with seat at 19" above finished floor.• P1 - Lavatory: Kohler "Solo" 2084 wall-mount with K-8998 P-trap and 2 hangers. Provide Chicago Faucets 333-E12PSHAB single supply basin faucet with drainage trim and accessories, chrome plated brass.• P3 - Drinking fountain Elkay LK4406 Outdoor Drinking Fountain wall mount bi-level non-filtered non-refrigerated 316 stainless color = Gray.• FD1 - Floor drain, Rooms 1 and 2: PVC body with square nickel bgronze frame and grate, Zurn FD2322-ST FD shall include trap guard Trap Seal..• HB - Provide solid brass body hose bibb with brass handle mounted at 24" AFF where indicated.
Richard T. Reep Architect2707 Chelsea Street
Orlando, FL [email protected]
407-408-4953AR11827
Civil Engineer
Structural Engineer
The original sheet size is ARCH D 24" x 36". Copyright Richard T. Reep Architect, All rights reserved. c
Electrical Engineer
6/15/2020 4:08:27 PM
P100
Plumbing Plan
15 June 2020
Issued for Bid
Cen
tral W
inds
Par
k -
Trai
lhea
d R
estro
om
City
of W
inte
r Spr
ings
1/4" = 1'-0"1 Plumbing Plan
1/8" = 1'-0"2 Plumbing Isometric - Sanitary
1" = 1'-0"3 Plumbing Specifications
J
OS
S; S3; S
4; S
K;
SWP; S
M; S
a
1
T
LEGEND DESCRIPTIONSYMBOL
NOTE: NOT EVERY ELECTRICAL LEGEND SYMBOL WILL BE USED
GFI
GFIWP
POWER PANELBOARD
JUNCTION BOX / EQUIPMENT CONNECTION
KEY NOTE IDENTIFIER
SWITCH: SINGLE; 3-WAY; 4-WAY; KEY SWITCH;WEATHERPROOF; MOTOR RATED; SWITCH LEG
DUPLEX RECEPTACLE
GFI DUPLEX RECEPTACLE
GFI, WEATHERPROOF HOUSING DUPLEXRECEPTACLE
A1
a 1L1-1
SWITCH LEG
FIXTURE TYPE
CIRCUIT DESIGNATION
TYPICAL LIGHTING FIXTUREDESIGNATIONS:
WALL MOUNTED OCCUPANCY SENSOR - AUTO ON/OFF
DISCONNECT SWITCH
GROUND ROD
TRANSFORMER
WALL MOUNTED LIGHT FIXTURE
RECESSED DOWN LIGHT
3#3/0, #3G, 2"C
CONDUIT SIZE
GROUND CONDUCTOR SIZE
QUANTITY AND SIZE OF CONDUCTORS
ELECTRICAL LEGEND:1. APPLICABLE CODES:
6TH EDITION, FLORIDA BUILDING CODE - BUILDING (2017) 6TH EDITION, FLORIDA BUILDING CODE - ACCESSIBILITY (2017) 6TH EDITION, FLORIDA BUILDING CODE - MECHANICAL (2017) 6TH EDITION, FLORIDA BUILDING CODE - PLUMBING (2017) 6TH EDITION, FLORIDA FIRE PREVENTION CODE (2017) NFPA 70, NATIONAL ELECTRICAL CODE (2014)
2. IT IS THE INTENT OF THESE CONTRACT DRAWINGS TO PROVIDE A COMPLETE AND WORKABLE FACILITY.
3. DESIGN DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW ALL OFFSETS, BENDS, ELBOWS, OR OTHER SPECIFIC ELEMENTS THAT MAY BE REQUIRED FOR PROPERINSTALLATION OF THE WORK. SUCH WORK SHALL BE VERIFIED AT THE SITE. ADDITIONAL BENDS, OFFSETS, AND CONDUIT AS REQUIRED BY VERTICAL AND HORIZONTALEQUIPMENT LOCATIONS OR OTHER JOB CONDITIONS, SHALL BE PROVIDED TO COMPLETE THE WORK AT NO ADDITIONAL COST TO THE OWNER.
4. EXCEPT WHERE SHOWN IN DIMENSIONAL DETAIL, THE LOCATIONS OF EQUIPMENT SHOWN ON PLANS ARE APPROXIMATE. SUCH ITEMS SHALL BE PLACED TO ELIMINATEINTERFERENCE WITH OTHER EQUIPMENT. THE EXACT LOCATIONS SHALL BE DETERMINED IN THE FIELD.
5. ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE NATIONAL & LOCAL CODES.
6. MATERIALS SHALL BE LISTED BY THE UNDERWRITER'S LABORATORIES, INC. SHOULD PLANS AND CODES CONFLICT, CONTACT THE CONSTRUCTION MANAGER. MAKE NOCHANGES, EVEN IN CASE OF CONFLICT, WITHOUT FIRST OBTAINING THE APPROVAL OF THE CONSTRUCTION MANAGER.
7. IN ACCORDANCE WITH NFPA 70, GROUND EXPOSED, NON CURRENT CARRYING METALLIC PARTS OF ELECTRICAL EQUIPMENT, METALLIC RACEWAY SYSTEMS, GROUNDINGCONDUCTOR IN METALLIC RACEWAYS.
8. BONDING JUMPERS SHALL BE USED TO BOND CONDUIT TO ENCLOSURES, BOXES, AND EQUIPMENT WHERE CONCENTRIC OR ECCENTRIC KNOCKOUTS ARE USED.
9. EQUIPMENT SIZES INDICATED ARE MINIMUM, BEFORE INSTALLING ANY WIRE OR CONDUIT, THE SUBCONTRACTOR SHALL OBTAIN THE EXACT EQUIPMENT REQUIREMENTSAND SHALL INSTALL WIRE, CONDUIT, CIRCUIT BREAKERS AND OTHER ITEMS OF THE CORRECT SIZE FOR THE EQUIPMENT ACTUALLY INSTALLED. HOWEVER, WIRE ANDCONDUIT SIZES FOR THE EQUIPMENT SHALL BE TAKEN AS A MINIMUM AND SHALL NOT BE REDUCED WITHOUT WRITTEN APPROVAL.
10. THE INSTALLATION OF THE ELECTRICAL WORK SHALL BE COORDINATED WITH THE WORK OF THE OTHER TRADES.
11. THE INSTALLATION SHALL BE ACCOMPLISHED BY WORKERS SKILLED IN THIS TYPE OF WORK WITH APPROPRIATE LICENSES.
12. THE CONTRACTOR SHALL INSTALL HIS WORK IN SUCH A MANNER AND AT SUCH A TIME AS WILL REQUIRE A MINIMUM OF CUTTING AND PATCHING OF THE BUILDINGSTRUCTURE.
13. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROTECT EXISTING UTILITIES FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE FOR REPAIR ORREPLACEMENT OF THE UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE COMPLETION OF THIS WORK.
14. ALL BOLTS, NUTS, WASHERS, ETC. USED FOR GROUNDING AND BONDING CONNECTIONS SHALL BE SILICON BRONZE. CONTRACTOR SHALL UTILIZE CONNECTORS TOPREVENT GALVANICACTION.
15. ALL EXPOSED ELECTRICAL CONDUIT VULNERABLE TO MECHANICAL DAMAGE SHALL BE RIGID GALVANIZED STEEL, UNLESS NOTED OTHERWISE. ALL OTHER CONDUITINSIDE FACILITY SHALL BE ELECTRICAL METAL TUBE (EMT). CONDUITS SHALL BE SUPPORTED BY SUITABLE CLAMPS, HANGERS OR STRAPS TO PROVIDE A RIGIDINSTALLATION.
16. CONDUIT SUPPORTS SHALL NOT BE FASTENED OR ATTACHED TO OTHER PIPES. PERFORATED STRAP HANGERS WILL NOT BE ALLOWED. EMPTY CONDUIT SHALL BETHOROUGHLY SWABBED OUT WITH DRY SWAB TO REMOVE MOISTURE AND DEBRIS BEFORE WIRE IS DRAWN IN. END OF CONDUIT SHALL BE TIGHTLY PLUGGED UNTILWIRE IS PULLED. NO CONDUIT SHALL BE LOCATED TO IMPAIR THE STRENGTH OF STRUCTURAL MEMBERS. MAKE CHANGES IN DIRECTION OF RUNS WITH SYMMETRICALBENDS. DO NOT INSTALL CRUSHED OR DEFORMED CONDUITS. AVOID TRAPPED CONDUITS. PREVENT PLASTER, DIRT, OR TRASH FROM LODGING IN CONDUIT, BOXES,FITTINGS. FREE CLOGGED CONDUITS OF OBSTRUCTIONS.
17. CONTRACTOR SHALL PROVIDE ALL NECESSARY LUGS FOR NEW PANELBOARDS AND ELECTRICAL EQUIPMENT TO HANDLE THE NUMBER AND SIZE OF CONDUCTORSSHOWN ON CONTRACT DOCUMENTS.
GENERAL ELECTRICAL NOTES:
SECTION 260519 - LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES
PART 1 - GENERAL
1.1 ACTION SUBMITTALS
A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT.
PART 2 - PRODUCTS
2.1 COPPER BUILDING WIRE
A. DESCRIPTION: FLEXIBLE, INSULATED AND UNINSULATED, DRAWN COPPER CURRENT-CARRYING CONDUCTOR WITH AN OVERALL INSULATION LAYER OR JACKET, OR BOTH, RATED 600 V OR LESS.
B. STANDARDS: LISTED AND LABELED AS DEFINED IN NFPA 70, BY A QUALIFIED TESTING AGENCY, AND MARKED FOR INTENDED LOCATION AND USE. ROHS COMPLIANT.
C. CONDUCTORS: COPPER, COMPLYING WITH ASTM B 3 FOR BARE ANNEALED COPPER AND WITH ASTM B 8 FOR STRANDED CONDUCTORS.
D. CONDUCTOR INSULATION: TYPE THHN AND TYPE THWN-2. COMPLY WITH UL 83.
2.2 CONNECTORS AND SPLICES
A. DESCRIPTION: FACTORY-FABRICATED CONNECTORS AND SPLICES OF SIZE, AMPACITY RATING, MATERIAL, TYPE, AND CLASS FOR APPLICATION AND SERVICE INDICATED; LISTED AND LABELED AS DEFINED IN NFPA 70, BY A QUALIFIED TESTING AGENCY, AND MARKED FOR INTENDED LOCATION AND USE.
PART 3 - EXECUTION
3.1 CONDUCTOR MATERIAL APPLICATIONS
A. FEEDERS: COPPER; SOLID FOR NO. 10 AWG AND SMALLER; STRANDED FOR NO. 8 AWG AND LARGER.
B. BRANCH CIRCUITS: COPPER. SOLID FOR NO. 10 AWG AND SMALLER; STRANDED FOR NO. 8 AWG AND LARGER.
3.2 CONDUCTOR INSULATION AND MULTICONDUCTOR CABLE APPLICATIONS AND WIRING METHODS
A. SERVICE ENTRANCE: TYPE THHN/THWN-2, SINGLE CONDUCTORS IN RACEWAY
B. FEEDERS: TYPE THHN/THWN-2, SINGLE CONDUCTORS IN RACEWAY
C. EXPOSED BRANCH CIRCUITS: TYPE THHN/THWN-2, SINGLE CONDUCTORS IN RACEWAY
3.3 INSTALLATION OF CONDUCTORS AND CABLES
A. CONCEAL CABLES IN FINISHED WALLS, CEILINGS, AND FLOORS UNLESS OTHERWISE INDICATED.
B. IDENTIFY AND COLOR-CODE CONDUCTORS AND CABLES.
SECTION 260526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMSPART 1 - GENERAL
1.1 BONDING AND EQUIPMENT GROUNDING
A. ALL ELECTRICAL EQUIPMENT (METALLIC CONDUIT, PANELBOARDS, ETC.) SHALL BE BONDED TOGETHER WITH A GREEN INSULATED COPPER SYSTEM GROUNDING CONDUCTOR IN ACCORDANCE WITH SPECIFIC RULES OF ARTICLE 250 OF THE NEC EQUIPMENT GROUNDING CONDUCTORS THROUGH THE RACEWAY SYSTEM AND FROM PANEL GROUNDING BAR OF EACH PANELBOARD TO BRANCH CIRCUIT EQUIPMENT AND DEVICES.
B. EQUIPMENT GROUNDING CONDUCTORS: ALL RACEWAYS SHALL HAVE AN INSULATED COPPER SYSTEM GROUND CONDUCTOR RUN THROUGHOUT THE ENTIRE LENGTH OF CIRCUIT INSTALLED WITHIN CONDUIT IN STRICT ACCORDANCE WITH NEC. GROUNDING CONDUCTOR SHALL BE INCLUDED IN TOTAL CONDUIT FILL WHEN DETERMINING CONDUIT SIZES, EVEN THOUGH NOT INCLUDED OR SHOWN ON DRAWINGS.
PART 2 - PRODUCTS
2.1 NOT USED
PART 3 - EXECUTION
3.1 EQUIPMENT GROUNDING
A. INSTALL INSULATED EQUIPMENT GROUNDING CONDUCTORS WITH ALL FEEDERS AND BRANCH CIRCUITS.
SECTION 260533 - RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS
PART 1 - GENERAL
1.1 SUBMITTALS
A. FOR ALL PRODUCTS.
PART 2 - PRODUCTS
2.1 METAL CONDUITS, TUBING, AND FITTINGS
A. METAL CONDUITS, TUBING, AND FITTINGS SHALL BE LISTED AND LABELED AS DEFINED IN NFPA 70, BY A QUALIFIED TESTING AGENCY, AND MARKED FOR INTENDED LOCATION AND APPLICATION.
B. GRC: COMPLY WITH ANSI C80.1 AND UL 6.
C. EMT: COMPLY WITH ANSI C80.3 AND UL 797.
D. FITTINGS FOR METAL CONDUIT: COMPLY WITH NEMA FB 1 AND UL 514B.
2.2 NONMETALLIC CONDUITS, TUBING, AND FITTINGS
A. LISTING AND LABELING: NONMETALLIC CONDUITS, TUBING, AND FITTINGS SHALL BE LISTED AND LABELED AS DEFINED IN NFPA 70, BY A QUALIFIED TESTING AGENCY, AND MARKED FOR INTENDED LOCATION AND APPLICATION.
B. RNC: TYPE EPC-40-PVC, COMPLYING WITH NEMA TC 2 AND UL 651 UNLESS OTHERWISE INDICATED.
C. FITTINGS FOR RNC: COMPLY WITH NEMA TC 3; MATCH TO CONDUIT OR TUBING TYPE AND MATERIAL.
2.3 BOXES, ENCLOSURES, AND CABINETS
A. SHEET METAL OUTLET AND DEVICE BOXES: COMPLY WITH NEMA OS 1 AND UL 514A.
B. CAST-METAL OUTLET AND DEVICE BOXES: COMPLY WITH NEMA FB 1, FERROUS ALLOY, TYPE FD, WITH GASKETED COVER.
C. SMALL SHEET METAL PULL AND JUNCTION BOXES: NEMA OS 1.
PART 3 - EXECUTION
3.1 RACEWAY APPLICATION
A. OUTDOORS:
1. EXPOSED CONDUIT: GRC.
2. CONCEALED CONDUIT, ABOVEGROUND: GRC, IMC OR EMT.
3. UNDERGROUND CONDUIT: RNC, TYPE EPC-40-PVC.
4. BOXES AND ENCLOSURES, ABOVEGROUND: NEMA 250, TYPE 3R.
B. INDOORS:
1. EXPOSED, NOT SUBJECT TO SEVERE PHYSICAL DAMAGE: EMT.
2. EXPOSED AND SUBJECT TO SEVERE PHYSICAL DAMAGE: GRC.
3. CONCEALED IN CEILINGS AND INTERIOR WALLS AND PARTITIONS: EMT
4. BOXES AND ENCLOSURES: NEMA 250, TYPE 1.
C. MINIMUM RACEWAY SIZE: 1/2-INCH.
3.2 FIRESTOPPING
A. INSTALL FIRESTOPPING AT PENETRATIONS OF FIRE-RATED FLOOR AND WALL ASSEMBLIES.
SECTION 262416 - PANELBOARDSPART 1 - GENERAL
1.1 ACTION SUBMITTALS
A. PRODUCT DATA: FOR EACH TYPE OF PANELBOARD.
B. SHOP DRAWINGS: FOR EACH PANELBOARD AND RELATED EQUIPMENT.
1.2 WARRANTY
A. MANUFACTURER'S WARRANTY: MANUFACTURER AGREES TO REPAIR OR REPLACE PANELBOARDS THAT FAIL IN MATERIALS OR WORKMANSHIP WITHIN 12 MONTHS FROM DATE OF SUBSTANTIAL COMPLETION.
B. SPD WARRANTY: MANUFACTURER AGREES TO REPAIR OR REPLACE PANELBOARDS THAT FAIL IN MATERIALS OR WORKMANSHIP WITHIN 60 MONTHS FROM DATE OF SUBSTANTIAL COMPLETION.
PART 2 - PRODUCTS
2.1 PANELBOARDS
A. MANUFACTURERS: EATON, SIEMENS, SQUARE D, GE
B. COMPLY WITH NEMA PB 1 AND NFPA 70.
C. ENCLOSURES: SURFACE-MOUNTED, DEAD-FRONT CABINETS.
D. PHASE, NEUTRAL, AND GROUND BUSES: COPPER
E. CONDUCTOR CONNECTORS: SUITABLE FOR USE WITH CONDUCTOR MATERIAL AND SIZES SPECIFIED. TERMINATIONS SHALL ALLOW USE OF 75 DEG C RATED CONDUCTORS WITHOUT DERATING. LUGS SUITABLE FOR INDICATED CONDUCTOR SIZES, WITH ADDITIONAL GUTTER SPACE, IF REQUIRED, FOR LARGER CONDUCTORS.
F. RATED FOR SERIES-CONNECTED SYSTEM WITH INTEGRAL OR REMOTE UPSTREAM OVERCURRENT PROTECTIVE DEVICES.
G. SURGE SUPPRESSION: FACTORY INSTALLED AS AN INTEGRAL PART OF PANELBOARDS, COMPLYING WITH UL 1449.
2.2 IDENTIFICATION
A. PANELBOARD LABEL: MANUFACTURER'S NAME AND TRADEMARK, VOLTAGE, AMPERAGE, NUMBER OF PHASES, AND NUMBER OF POLES SHALL BE LOCATED ON THE INTERIOR OF THE PANELBOARD DOOR.
B. CIRCUIT DIRECTORY: DIRECTORY CARD INSIDE PANELBOARD DOOR, MOUNTED IN TRANSPARENT CARD HOLDER. CIRCUIT DIRECTORY SHALL IDENTIFY SPECIFIC PURPOSE WITH DETAIL SUFFICIENT TO DISTINGUISH IT FROM ALL OTHER CIRCUITS.
PART 3 - EXECUTION
3.1 IDENTIFICATION
A. CREATE A DIRECTORY TO INDICATE INSTALLED CIRCUIT LOADS AND INCORPORATE OWNER'S FINAL ROOM DESIGNATIONS.
B. LABEL EACH PANELBOARD WITH A NAMEPLATE. INSTALL WARNING SIGNS AND ARC-FLASH LABEL.
ELECTRICAL SPECIFICATIONS
DEVICE MOUNTING HEIGHTSSWITCHES 48" AFF TO CENTERLINE OF DEVICE
RECEPTACLES 18" AFF TO CENTERLINE OF DEVICE
COUNTER HEIGHT RECEPTACLE48" AFF TO CENTERLINE OF DEVICE OR 2"ABOVE BACKSPLASH, COORDINATE WITHARCHITECTURAL ELEVATIONS
EXTERIOR WALL RECEPTACLES 24" AFF TO BOTTOM OF DEVICE
Richard T. Reep Architect2707 Chelsea Street
Orlando, FL [email protected]
407-408-4953AR11827
Civil Engineer
Structural Engineer
The original sheet size is ARCH D 24" x 36". Copyright Richard T. Reep Architect, All rights reserved. c
Electrical Engineer
6/15/2020 4:08:04 PM
E100
Electrical Notes
15 June 2020
Issued for Bid
Cen
tral W
inds
Par
k -
Trai
lhea
d R
estro
om
City
of W
inte
r Spr
ings
6" = 1'-0"1 Electrical Notes
BASIS OF DESIGN: ACUITY NLIGHT.NUMBER OF SWITCHES AND SENSORS AS SHOWN ON THE PLANS.
A
B B
TO
FROM
WALL SWITCHOCCUPANCY SENSOR LIGHTING
POWER PACK
OSD
OS
J J
OS OS
OS
ELECTRIC METER
PANEL P
GFIP-1
WP-2
WP-2
WP-2
WP-2
EWCGFIP-3
DP-2
DP-2
DP-2S
MEF-1P-5
SM
EF-1P-5
NOTES1. PROVIDE 2 #12, 1 #12G, 3/4"C FOR ALL CIRCUITS.2. EXHAUST FANS ARE CONTROLLED VIA OCCUPANCY SENSOR3. FOR EXTERIOR LIGHTING LOCATIONS, SEE SHEET A200 EXTERIOR ELEVATIONS.
WP-2
WP-2
Richard T. Reep Architect2707 Chelsea Street
Orlando, FL [email protected]
407-408-4953AR11827
Civil Engineer
Structural Engineer
The original sheet size is ARCH D 24" x 36". Copyright Richard T. Reep Architect, All rights reserved. c
Electrical Engineer
6/15/2020 4:08:05 PM
E200
ElectricalPlans, Panel
Schedule,Diagrams
15 June 2020
Issued for Bid
Cen
tral W
inds
Par
k -
Trai
lhea
d R
estro
om
City
of W
inte
r Spr
ings
1" = 20'-0"2 Site Plan - Electrical
1" = 20'
20' 0 20' 40'
GRAPHIC SCALE
GRAPHIC SCALE
2'
1/4"=1'-0"
0' 12'8'4'
M
DUKE ENERGY UTILITYTRANSFORMER
#2G
BUILDING STEEL
METALLIC WATER PIPING
EXTERNALBONDING BAR
TEST WELL
5/8" X 20' GROUND ROD
#2G IN 3/4"CONDUIT
CONCRETE ENCASEDFOOTER REBAR
LIGHTING FIXTURE SCHEDULETYPE DESCRIPTION CATALOG LAMP VOLTAGE REMARKS
D4" LOW PROFILE, SURFACEM OUNTED, LED
WRAPAROUND FIXTURE. 4000 LUMENS, CURVED RIBBED DIFFUSER, 82 CRI, 4000K CCT, WHITE FINISH.
LITHONIA #BLWP4-40L-ADP-EZI-LP840 35W LED 120/277
W
ARCHITECTURAL WALL SCONCE LED FIXTURE, 1200LUMENS OUTPUT, 4000K CCT, 80 CRI, 4W LED.
NATURAL ALUMINUM FINISH. PHOTOCELLCONTROLLED.
LITHONIA #WDGE1LED-P1-40K-80CRI-VW-MVOLT-PE-DNAXD
4W LED 120/277SEE A200 FOR
MOUNTING LOCATIONS.
#2 BONDINGJUMPER
PANEL: P RATING: 100A SERVICE: 120/208V, 1PHASE,3W FED FROM: UTILITY TRANSFORMERTYPE: NEMA1 AIC: 10 KAIC SURFACE/FLUSH: SURFACE MLO/MCB: 60AMCB
BRANCH CIRCUIT BRANCH CIRCUIT
CKT LOAD DESCRIPTIONLOAD (KVA) CKT BKR CKT BKR LOAD (KVA)
LOAD DESCRIPTION CKTØA ØB POLE TRIP POLE TRIP ØA ØB
1 RECEPTACLE 180 1 20 1 20 129 LIGHTING 23 ELECTRIC WATER COOLER 500 1 20 1 20 1440 LIFT STATION 45 EXHAUST FANS 360 1 20 1 20 67 1 20 1 20 89 1 20 1 20 1011
2 501 20 12
13 1 20 1415
2 50 2 30 SURGE PROTECTIVE DEVICE16
17 18540 500 VA SUB‐TOTALS 129 1440
PANEL: P REC LTG MTR EQUPCONNECTED VA 680 129 360 1440DEMAND FACTOR NEC 125% 75% 100%
DEMAND VA 680 161 270 1440TOTAL CONNECTED AMPS: 13 ATOTAL DEMAND AMPS: 12 A
WPGFIP-4
RECEPTACLE FOR LIFTSTATION. MOUNTINSIDE LIFT STATIONVAULT
120/240V, 1�PANEL P
INCOMING UTILITY
3#300KCMIL, 3"CL =650'VD = 1.94% ELECTRIC
SERVICEMETER
#2G IN 3/4"C
NG
3#300KCMIL, 3"CL < 5'VD = 0.01%
NTS2 SINGLE LINE DIAGRAM 12" = 1'-0"3 Lighting Control Diagram - Auto on / Auto off
1/4" = 1'-0"1 Electrical Floor Plan
NOTES:SERVICE HAS BEEN SIZED FOR MAXIMUM 2% VOLTAGE DROP. BRANCH CIRCUITS HAVE BEEN SIZED FOR MAXIMUM 3% VOLTAGE DROP. VOLTAGE DROP FOR FEEDERS AND BRANCH CIRCUITS COMBINED HAVE BEEN SIZED FOR A MAXIMUM OF 5% VOLTAGE DROP PER FBC-EC C405.6.3.
120V RECEPTACLE AND LIGHTING BRANCH FEEDER CONDUCTORS HAVE BEEN SIZED FOR A MAXIMUM 3% VOLTAGE DROP FROM THE PANEL TO THE LOAD.
CONTRACTOR SHALL PROVIDE AND INSTALL CONDUIT AND CONDUCTORS FROM DUKE ENERGY TRANSFORMER.