Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
\\albany.city\data\works & services\city engineering\engineering\04 drafting\__city of albany autocad files\coa standard drawings\coa std drawings.dwg
102 NORTH ROAD, YAKAMIA WA 6330PO BOX 484 ALBANY WA 6331
Tel: (08) 9841 9333Fax: (08) 9841 4099
Email: [email protected]: www.albany.wa.gov.au
CITY OF ALBANY ENGINEERING SERVICESSTANDARD CONSTRUCTION DRAWINGS
CATEGORY DRAWING No. DRAWING TITLE REVISION
DRAINAGE STD-01-01 TYPICAL MANHOLE REV 0STD-01-02 UNIVERSAL SIDE ENTRY PIT REV 0STD-01-03 COMBINATION SIDE ENTRY PIT REV 0STD-01-04 GRATED GULLY PIT REV 0STD-01-05 HOUSE CONNECTION PIT REV 0STD-01-06 UNDERGROUND STORAGE PIT REV 0STD-01-07 KERB OUTLET REV 0
KERBING STD-02-01 TYPE 1 KERB PROFILES REV 0STD-02-02 TYPE 2 KERB PROFILES REV 0STD-02-03 TYPE 3 KERB PROFILES REV 0STD-02-04 CONCRETE APRON REV 0
PATHWAYS STD-03-01 CONCRETE PATHWAY DETAILS REV 0STD-03-02 ASPHALT PATHWAY DETAILS REV 0STD-03-03 PEDESTRIAN RAMP - TYPE 1 REV 0STD-03-04 PEDESTRIAN RAMP - TYPE 2 REV 0
SIGNS STD-04-01 STREET NAME SIGNS REV 0
CROSSOVERS STD-05-01 STANDARD CROSSOVER - CONCRETE REV 0STD-05-02 STANDARD CROSSOVER - ASPHALT REV 0STD-05-03 STANDARD CROSSOVER - PAVED REV 0
SCALE 1:10STREET NAME PLATE
ALBANYRD
100 95 100TEXT LENGTH & TYPE VARIES
REFER TO NOTE 5 65 25
SIGN LENGTH VARIESREFER TO NOTE 4
TEXT LENGTH AND TYPEVARIES, REFER TO NOTE 5.
SIGN LENGTH VARIES
CITY OFALBANY LOGO. SIGN DEPTH VARIES
REFER TO NOTE 3.
FOR TEXT HEIGHTSREFER TO TABLE A
2500
MIN (30
00 M
AX)
SCALE: 1:25STEET SIGN DETAIL
∅300 x 600 DEEPCONCRETE FOOTING.
∅50nb GALVANISEDSIGN POST.
100
ALBANYRD
SUPPLEMENTARYPLATE.
GENERAL NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE SHOWN.2. ALL SIGN PLATES SHALL BE CONSTRUCTED FROM NON-CORROSIVE
ALUMINIUM EXTRUSIONS WITH A THICKNESS OF NO LESS THAN 3mm.SIGNS SHALL BE RECTANGULAR WITH THE LONG AXIS HORIZONTAL.WORDS SHALL BE WRITTEN HORIZONTALLY. ENDS SHALL BE CUTSQUARE.
3. MINIMUM DEPTH OF SIGNBOARD TO BE 150mm ON ROADS WHERESPEEDS ARE LESS THAN 70km/h. WHERE SPEEDS ARE GREATER AMINIMUM DEPTH OF 200mm IS TO BE USED.
4. THE MINIMUM LENGTH OF STREET NAME SIGNS SHALL BE 500mmAND THE MAXIMUM LENGTHS SHALL BE, 1200mm FOR SINGLE POSTEND-MOUNTED, 1800mm FOR CENTRE-MOUNTED AND 2000mm FORTWO-POST MOUNTED.
5. LETTERS FOR THE STREET NAME AND ALL LEGENDS ON THESUPPLEMENTARY PLATES SHALL BE SERIES D, AS SPECIFIED INAS 1744, EXCEPT THAT WHERE THIS WOULD OTHERWISE RESULT INAN OVERLENGTH SIGN, THE SIGN SHALL NOT BE LENGTHENED BUTTHE LETTERING MAY BE MADE PROPORTIONALLY NARROWER TO FITTHE AVAILABLE LENGTH. LETTERS SHALL BE NOT BE NARROWERTHAN SERIES C.
6. SIGN COLOUR CODE SHALL BE BLACK LETTERING ON A WHITEREFLECTIVE BACKGROUND. MIN DEPTH OF REFLECTORIZED SECTIONOF THE SIGN SHALL BE AT LEAST 130mm.
7. SIGNS TO BE FIXED TO STREET LIGHTS OR POLES WHERE POSSIBLE.
SCALE 1:10
CUL DE SAC
SCALE 1:10SUPPLEMENTARY PLATE
SIGN LENGTH VARIESREFER TO NOTE 4
100
505050 HIGH "SERIES D"LETTERING (TYPICAL)
100LESS THAN 70km/h
TRAFFIC SPEED
GREATER THAN 70km/h 130
50
65
TABLE ASTREET NAMELETTER HEIGHT
STREET TYPELETTER HEIGHT
2.5m
MIN C
LEAR
ANCE
FRO
MNA
TURA
L SU
RFAC
E TO
UNDE
RSIDE
OF S
IGN
N.T.S.90° DUAL SIGN MOUNT DETAIL
ALBANY RD
THIS DRAWING IS NOT TO BEUSED FOR CONSTRUCTION
UNLESS SIGNED AS APPROVED
102 NORTH ROAD, YAKAMIA WA 6330PO BOX 484 ALBANY WA 6331
Tel: (08) 9841 9333Fax: (08) 9841 4099
Email: [email protected]: www.albany.wa.gov.au 0
SHEET No
PROJECT
DRAWING NAME
DRAWING No
-FILE REF
DESIGNED
-JOB No
-SCALE
DRAWNAUTHORISED
DESCRIPTION APPROVED DATE
REV
REV
\\albany.city\data\works & services\city engineering\engineering\04 drafting\__city of albany autocad files\coa standard drawings\coa std drawings.dwg
APPROVED0 APPROVED DK 26/06/18 CITY OF ALBANY ENGINEERING SERVICESSTANDARD CONSTRUCTION DRAWINGS
STREET NAME SIGNSSTD-04-011:25 @ A3
JLP
2905 5
300
105
3075
125
250
125150 10
050
100
50
150
250
75 150 25
150
300
150
R25
R10
R25
SCALE: 1:5
MOUNTABLE KERB (TYPE 1)SCALE: 1:5
SEMI-MOUNTABLE KERB (TYPE 1)
R10
R25
SCALE: 1:5
BARRIER KERB (TYPE 1)
R10R25
R60
SCALE: 1:5
FLUSH KERB (TYPE 1)
3 N10 BARS @ 100mm CRS. LOCATEDCENTRALLY WHERE REQUIRED.
R10R10
10
1010
SCALE: 1:2EXPANSION JOINT DETAIL
BUTYL-MASTICPOLYMER SEALANT.
FOAM OR POLYTHENEBACKING.
EXPANSION GAP.
CONCRETE.
SCALE: 1:5TYPICAL KERB KEYING
250x100 CONCRETEKEY.
TYPICAL KERBPROFILES.
THIS DRAWING IS NOT TO BEUSED FOR CONSTRUCTION
UNLESS SIGNED AS APPROVED
102 NORTH ROAD, YAKAMIA WA 6330PO BOX 484 ALBANY WA 6331
Tel: (08) 9841 9333Fax: (08) 9841 4099
Email: [email protected]: www.albany.wa.gov.au 0
SHEET No
PROJECT
DRAWING NAME
DRAWING No
-FILE REF
DESIGNED
-JOB No
-SCALE
DRAWNAUTHORISED
DESCRIPTION APPROVED DATE
REV
REV
\\albany.city\data\works & services\city engineering\engineering\04 drafting\__city of albany autocad files\coa standard drawings\coa std drawings.dwg
APPROVED0 APPROVED DK 26/06/18 CITY OF ALBANY ENGINEERING SERVICESSTANDARD CONSTRUCTION DRAWINGS
TYPE 1 KERB PROFILES - 2 COAT SEALSTD-02-011:25 @ A3
JLP
NOTES:
1. CONCRETE FOR KERBING SHALL CONFORM TO AS 1379-1991.2. MINIMUM COMPRESSIVE STRENGTH 25MPa AT 28 DAYS.3. MAXIMUM AGGREGATE SIZE 14mm.4. MAXIMUM SLUMP 75mm.5. KEYED KERBING SHALL BE PROVIDED WHERE RADIUS OF
CURVATURE IS LESS THAN 40m.6. ALL TYPE 1 MOUNTABLE KERB TO BE KEYED.7. CONTRACTION JOINTS SHALL BE PROVIDED AT 2.0m
CENTRES CONSISTING OF A GROOVE TROWELLED INTO THECONCRETE SURFACE.
8. EVERY ALTERNATE JOINT SHALL BE AN EXPANSION JOINTAND SHALL CONSIST OF A FOAM FILLED, MASTIC GAP,10mm WIDE CUT TO THE FULL DEPTH OF THE KERB.
2000
500CROSSOVER
WIDTH 500
SCALE: 1:100PLAN
PROPERTY BOUNDARY
COUN
CIL
VERG
E WIDTH
VAR
IES
A -A -
EXISTING ROAD 2500
2.0% 2-4%
SCALE: 1:50SECTION A-A
PROP
ERTY
BOU
NDAR
Y
CONCRETE CROSSOVER.REFER TO TABLE FOR DETAILS.
SUB-BASE COMPACTED TO 98% MMDD.REFER TO TABLE FOR DETAILS.
EXISTING SUBGRADE COMPACTED TO95% MMDD TO A DEPTH OF 250mm.
MINIMUM WIDTH@ BOUNDARYCROSSOVER CLASS
3.0m1 OR 2 DWELLINGSON A SINGLE LOT
MAXIMUM WIDTH@ BOUNDARY
6.0m
MAXIMUM WIDTH@ ROAD
7.0m
ALLOWABLE CROSSOVER DIMENSIONS
3.0mSINGLE RESIDENTIALON HIGHWAY OR MRD 6.0m 7.0m
3.0mGROUPED DWELLINGS3 OR MORE 7.5m 7.5m
5.5mCOMMERCIAL
LIGHT INDUSTRIAL
6.0mHEAVY INDUSTRIAL 10.0m 10.0m
7.5mSERVICE STATIONS
7.5m 7.5m
5.5m 7.5m 7.5m
10.0m 10.0m
DOMESTIC
COMMERCIAL/INDUSTRIAL
HEAVY INDUSTRIAL
100mm
CONCRETETHICKNESS
150mm
200mm
20MPa
CONCRETESTRENGTH
25MPa
25MPa
-
MESHTYPE
F62
F62
75mm
SUB-BASETHICKNESS ON SAND
100mm
125mm
CROSSOVER CONSTRUCTION DETAILS
100mm
SUB-BASETHICKNESS ON CLAY
125mm
150mm
CROSSOVER TYPE
THIS DRAWING IS NOT TO BEUSED FOR CONSTRUCTION
UNLESS SIGNED AS APPROVED
102 NORTH ROAD, YAKAMIA WA 6330PO BOX 484 ALBANY WA 6331
Tel: (08) 9841 9333Fax: (08) 9841 4099
Email: [email protected]: www.albany.wa.gov.au 0
SHEET No
PROJECT
DRAWING NAME
DRAWING No
-FILE REF
DESIGNED
-JOB No
-SCALE
DRAWNAUTHORISED
DESCRIPTION APPROVED DATE
REV
REV
\\albany.city\data\works & services\city engineering\engineering\04 drafting\__city of albany autocad files\coa standard drawings\coa std drawings.dwg
APPROVED0 APPROVED DK 26/06/18 CITY OF ALBANY ENGINEERING SERVICESSTANDARD CONSTRUCTION DRAWINGS
STANDARD CROSSOVER - CONCRETESTD-05-01AS SHOWN
JLP
NOTES:
1. CROSSOVER TO GRADE UP @ 2.0% FROM BACK OFCONCRETE APRON OR MOUNTABLE KERB FOR ADISTANCE OF 2.5m.
2. FOR CROSSOVERS CONSTRUCTED ON NON KERBED ROADSASSUME KERB IN PLACE WHEN ESTABLISHING LEVELS.
3. WHERE THERE IS AN EXISTING PATHWAY IN VERGEREFER TO THE SPECIFICATION FOR DETAILS.
4. FOR COMMERCIAL/INDUSTRIAL AND HEAVY INDUSTRIALCROSSOVERS CONCRETE APRONS ARE TO BE REINFORCEDWITH F62 MESH.
5. FOR CROSSOVERS THAT DO NOT CONFORM TO THESESTANDARD LEVELS CONTACT CITY OF ALBANY FORFURTHER DETAILS.
OUTLET I.L.
LINER SIZE TO BEDETERMINED BY VOLUMEREQUIRED TO BE STORED.
LOT CONNECTION
300
PLAN SECTION A-A
NOMINAL 14mm AGGREGATEFILLED WEEP HOLE ONGEOTEXTILE SHEET.
ALL PIPES TO BE FINISHEDWITH MORTAR FILLET.50mm INSIDE, 100mm OUTSIDE
PRECAST CONCRETEBASE SLAB.
OUTLET HOLE TO DE DRILLED IN SCREWCAP. HOLE SIZE SIZE TO BE DETERMINEDBY FLOW RATES REQUIRED.
DISMOUNTABLE JOINER (MAINTENANCEACCESS) WHERE LESS THAN 300mmBETWEEN TOP OF RISER AND BASE OF LID.
PVC RISER TO BE PLACED OFFSET FROMMANHOLE COVER OPENING TO ALLOW EASEOF ACCESS TO BASE OF PIT VIA STEP IRONS.PIPE DIAMETER TO BE DETERMINED BYSTORMWATER CONVEYANCE REQUIREMENTS.
MORTAR BEDDING AND FILLET.
150
MIN
RISE
R HE
IGHT
DET
ERMINE
D BY
STOR
AGE
VOLU
ME R
EQUIRE
D
150mm PRECAST LIDWITH ACCESS HOLE.
PRECAST ACCESSCOVER WITH LID.
MORTARED BRICK SUPPORT TO BEPLACED UNDERNEATH CONNECTION.
INLET PIPE
A-
PRECAST ACCESSCOVER WITH LID.
SCALE: 1:25UNDERGROUND ATTENUATION PIT
A-
STEP IRONS.
NOTE: STEP IRONS TO BE INSTALLED WHERE DEPTH IS GREATERTHAN 1000mm FROM COVER TO BASE @300mm CENTRES.
BOTTOM STEP 300mm ABOVE BASE.
500
MAX
THIS DRAWING IS NOT TO BEUSED FOR CONSTRUCTION
UNLESS SIGNED AS APPROVED
102 NORTH ROAD, YAKAMIA WA 6330PO BOX 484 ALBANY WA 6331
Tel: (08) 9841 9333Fax: (08) 9841 4099
Email: [email protected]: www.albany.wa.gov.au 0
SHEET No
PROJECT
DRAWING NAME
DRAWING No
-FILE REF
DESIGNED
-JOB No
-SCALE
DRAWNAUTHORISED
DESCRIPTION APPROVED DATE
REV
REV
\\albany.city\data\works & services\city engineering\engineering\04 drafting\__city of albany autocad files\coa standard drawings\coa std drawings.dwg
APPROVED0 APPROVED DK 26/06/18 CITY OF ALBANY ENGINEERING SERVICESSTANDARD CONSTRUCTION DRAWINGS
UNDERGROUND ATTENUATION PITSTD-01-061:25 @ A3
JLP
DRAINAGELID LEVEL TO BEADJUSTED TO SUITFINISHED GROUND LEVEL.
PRECAST CONCRETE BASE SLAB.
ALL PIPES TO BE FINISHEDWITH MORTAR FILLET.50mm INSIDE, 100mm OUTSIDE
A-
A-
300
MAX
500
MAX
1200℄ OF
LINER
PLAN SECTION A-A
MORTAR BEDDINGAND FILLET.
FOR LINER SIZE REFERTO 'TABLE A'.
NOMINAL 14mm AGGREGATEFILLED WEEP HOLE ONGEOTEXTILE SHEET.
GEOTEXTILE WRAPTO BASE OF PIT
2.0%ASPHALTIC CONCRETE SEAL.
COMPACTED GRAVELBASECOURSE.
FOR LINER SIZE REFERTO TABLE 'A'.
CLASS D CONCRETELID WITH CAST IRONACCESS COVER.
PROPOSEDKERB.
SCALE: 1:25TYPICAL MANHOLE
NOTE: STEP IRONS TO BE INSTALLED WHERE DEPTH IS GREATERTHAN 1000mm FROM COVER TO BASE @300mm CENTRES.
BOTTOM STEP 300mm ABOVE BASE. STEP IRONS ARE TO BEBOLTED ON THE WALL FACING ONCOMING TRAFFIC.
PIPE SIZE ∅
225 - 450
525 - 600
TABLE A
DN1050
DN1200
LINER TO BE SPUNCONCRETE WITH
INTERLOCKING JOINTS
NOTE: WHEN MANHOLE IS LOCATEDIN PATHWAY COVER TO BE SQUARE.
THIS DRAWING IS NOT TO BEUSED FOR CONSTRUCTION
UNLESS SIGNED AS APPROVED
102 NORTH ROAD, YAKAMIA WA 6330PO BOX 484 ALBANY WA 6331
Tel: (08) 9841 9333Fax: (08) 9841 4099
Email: [email protected]: www.albany.wa.gov.au 0
SHEET No
PROJECT
DRAWING NAME
DRAWING No
-FILE REF
DESIGNED
-JOB No
-SCALE
DRAWNAUTHORISED
DESCRIPTION APPROVED DATE
REV
REV
\\albany.city\data\works & services\city engineering\engineering\04 drafting\__city of albany autocad files\coa standard drawings\coa std drawings.dwg
APPROVED0 APPROVED DK 26/06/18 CITY OF ALBANY ENGINEERING SERVICESSTANDARD CONSTRUCTION DRAWINGS
TYPICAL MANHOLESTD-01-011:25 @ A3
JLP
2000
500CROSSOVER
WIDTH 500
SCALE: 1:100PLAN
PROPERTY BOUNDARY
COUN
CIL
VERG
E WIDTH
VAR
IES
A -A -
EXISTING ROAD2500
2.0% 2-4%
EXISTING SUBGRADE COMPACTED TO95% MMDD TO A DEPTH OF 250mm.
SUB-BASE COMPACTED TO 95% MMDD.REFER TO TABLE FOR DETAILS.
PROP
ERTY
BOU
NDAR
Y
25mm (±10mm) BEDDING LAYER.
SCALE: 1:50SECTION A-A
SELECTED PAVERS.
MINIMUM WIDTH@ BOUNDARYCROSSOVER CLASS
3.0m1 OR 2 DWELLINGSON A SINGLE LOT
MAXIMUM WIDTH@ BOUNDARY
6.0m
MAXIMUM WIDTH@ ROAD
7.0m
ALLOWABLE CROSSOVER DIMENSIONS
3.0mSINGLE RESIDENTIALON HIGHWAY OR MRD 6.0m 7.0m
3.0mGROUPED DWELLINGS3 OR MORE 7.5m 7.5m
5.5mCOMMERCIAL
LIGHT INDUSTRIAL
6.0mHEAVY INDUSTRIAL 10.0m 10.0m
7.5mSERVICE STATIONS
7.5m 7.5m
5.5m 7.5m 7.5m
10.0m 10.0m
DOMESTIC
COMMERCIAL/INDUSTRIAL
HEAVY INDUSTRIAL
75mm
SUB-BASETHICKNESS ON SAND
100mm
125mm
CROSSOVER CONSTRUCTION DETAILS
100mm
SUB-BASETHICKNESS ON CLAY
125mm
150mm
CROSSOVER TYPE
SCALE: 1:20PAVING EDGE RESTRAINT DETAIL
SELECTED PAVERS.
200
75
BEDDING LAYER.COMPACTED SUB-BASE.
CONCRETE EDGERESTRAINT.
THIS DRAWING IS NOT TO BEUSED FOR CONSTRUCTION
UNLESS SIGNED AS APPROVED
102 NORTH ROAD, YAKAMIA WA 6330PO BOX 484 ALBANY WA 6331
Tel: (08) 9841 9333Fax: (08) 9841 4099
Email: [email protected]: www.albany.wa.gov.au 0
SHEET No
PROJECT
DRAWING NAME
DRAWING No
-FILE REF
DESIGNED
-JOB No
-SCALE
DRAWNAUTHORISED
DESCRIPTION APPROVED DATE
REV
REV
\\albany.city\data\works & services\city engineering\engineering\04 drafting\__city of albany autocad files\coa standard drawings\coa std drawings.dwg
APPROVED0 APPROVED DK 26/06/18 CITY OF ALBANY ENGINEERING SERVICESSTANDARD CONSTRUCTION DRAWINGS
STANDARD CROSSOVER - PAVEDSTD-05-03AS SHOWN
JLP
NOTES:
1. CROSSOVER TO GRADE UP @ 2.0% FROM BACK OFCONCRETE APRON OR MOUNTABLE KERB FOR ADISTANCE OF 2.5m.
2. FOR CROSSOVERS CONSTRUCTED ON NON KERBED ROADSASSUME KERB IN PLACE WHEN ESTABLISHING LEVELS.
3. WHERE THERE IS AN EXISTING PATHWAY IN VERGEREFER TO THE SPECIFICATION FOR DETAILS.
4. FOR CROSSOVERS THAT DO NOT CONFORM TO THESESTANDARD LEVELS CONTACT CITY OF ALBANY FORFURTHER DETAILS.
1500
1500
300
TRAP
50mm PRECASTCONCRETE COVER.
∅150mm STORMWATERINLET FROM DEVELOPMENT.
A-
A-
LOT BOUNDARY
LOT
BOUN
DARY
∅150mm STORMWATERINLET FROM DEVELOPMENT.
∅100mm DWV STORMWATEROUTLET TO COUNCIL SYSTEM.
PLAN SECTION A-A
∅100mm DWV STORMWATEROUTLET TO COUNCIL SYSTEM.
REINFORCED CONCRETEOR PLASTIC LINER
50mm PRECASTCONCRETE BASE.
SCALE: 1:25HOUSE CONNECTION PIT
300mm WEEPHOLEWITH GRANULAR FILL.
NOTE:
MAINTENANCE RESPONSIBILITYFOR THIS MANHOLE REMAINSWITH THE PROPERTY OWNER.
LESS THAN 1200
GREATER THAN 1200
HOUSE CONNECTION PIT TABLE
600
900 WITH STEP IRONS
H.C. PIT DEPTH INSIDE DIAMETER
ALL PVC PIPES TO BE FINISHEDWITH MORTAR FILLET.50mm INSIDE, 100mm OUTSIDE.
NOTE: WHERE CONNECTION IS REQUIRED TO CITYOF ALBANY STORMWATER INFRASTRUCTURE,A PERMIT IS REQUIRED PRIOR TO CONNECTION.
THIS DRAWING IS NOT TO BEUSED FOR CONSTRUCTION
UNLESS SIGNED AS APPROVED
102 NORTH ROAD, YAKAMIA WA 6330PO BOX 484 ALBANY WA 6331
Tel: (08) 9841 9333Fax: (08) 9841 4099
Email: [email protected]: www.albany.wa.gov.au 0
SHEET No
PROJECT
DRAWING NAME
DRAWING No
-FILE REF
DESIGNED
-JOB No
-SCALE
DRAWNAUTHORISED
DESCRIPTION APPROVED DATE
REV
REV
\\albany.city\data\works & services\city engineering\engineering\04 drafting\__city of albany autocad files\coa standard drawings\coa std drawings.dwg
APPROVED0 APPROVED DK 26/06/18 CITY OF ALBANY ENGINEERING SERVICESSTANDARD CONSTRUCTION DRAWINGS
HOUSE CONNECTION PITSTD-01-051:25 @ A3
JLP
270DN1050 = 830DN1200 = 900
25
600
600
(TYP
)
PRECAST CONCRETE BASE SLAB.
HEAVY DUTY UNIVERSAL SIDEENTRY PIT FRAME AND COVER.
PLAN SECTION A-A
SCALE: 1:25UNIVERSAL SIDE ENTRY PIT
A-
2.0%
HEAVY DUTYCONVERSION/DIVERSIONSLAB TO SUIT LINER SIZE.
DEFLECTOR SLAB REQUIREDFOR ALL PITS EXCEPT WHENLOCATED AT LOW POINT.
PAVEMENT IN THIS AREA TOBE DEPRESSED FROM NORMALPAVEMENT LEVEL TO MATCHDEFLECTOR SLAB LEVEL.
FLOW
A-
HAND FORMED CONCRETEAPRON. THICKNESS TO MATCHDEPTH OF DEFLECTOR SLAB.
STEP IRONS FACINGONCOMING TRAFFIC.
CEMENT MORTAR CORNERS.
KERB WIDTH TO BE MAINTAINEDAROUND SWEEP AND GRADEDOWN TO TOP OF FRAME.
EXPANSION JOINT (TYP). ALL PIPES TO BE FINISHEDWITH MORTAR FILLET.50mm INSIDE, 100mm OUTSIDE
900
PIPE SIZE ∅
225 - 450
525 - 600
TABLE A
DN1050
DN1200
LINER TO BE SPUNCONCRETE WITH
INTERLOCKING JOINTS
SET EDGE OF SLAB 25mm BELOWFINISHED LEVEL. TAPER BASEAND SEAL OVER 300mm TOMATCH TOP OF SLAB.
ASPHALTIC CONCRETE SEAL.
COMPACTED GRAVELBASECOURSE.
100mm THICK CEMENT STABILISEDROADBASE OR CONCRETE.
INSIDE FACE OF PRECAST UNITSTO BE FLUSH ALL AROUND.
FRAME TO BE BEDDEDON 12mm MORTAR.
MORTAR BEDDINGAND FILLET.
FOR LINER SIZE REFERTO 'TABLE A'.
NOMINAL 14mm AGGREGATEFILLED WEEP HOLE ONGEOTEXTILE SHEET.
GEOTEXTILE WRAPTO BASE OF PIT
NOTE: STEP IRONS TO BE INSTALLED WHERE DEPTH IS GREATERTHAN 1000mm FROM COVER TO BASE @300mm CENTRES.
BOTTOM STEP 300mm ABOVE BASE. STEP IRONS ARE TO BEBOLTED ON THE WALL FACING ONCOMING TRAFFIC.
℄ OF
LINER
℄ OF
PIPE
FOAM JOINT (TYP).
THIS DRAWING IS NOT TO BEUSED FOR CONSTRUCTION
UNLESS SIGNED AS APPROVED
102 NORTH ROAD, YAKAMIA WA 6330PO BOX 484 ALBANY WA 6331
Tel: (08) 9841 9333Fax: (08) 9841 4099
Email: [email protected]: www.albany.wa.gov.au 0
SHEET No
PROJECT
DRAWING NAME
DRAWING No
-FILE REF
DESIGNED
-JOB No
-SCALE
DRAWNAUTHORISED
DESCRIPTION APPROVED DATE
REV
REV
\\albany.city\data\works & services\city engineering\engineering\04 drafting\__city of albany autocad files\coa standard drawings\coa std drawings.dwg
APPROVED0 APPROVED DK 26/06/18 CITY OF ALBANY ENGINEERING SERVICESSTANDARD CONSTRUCTION DRAWINGS
UNIVERSAL SIDE ENTRY PITSTD-01-021:25 @ A3
JLP
A -
45° 45°
WIDTH OF PATHWAY VARIESVARIES
KERB.
EXPANSION JOINT. EXPANSION JOINT.
SCALE: 1:50PEDESTRIAN RAMP - TYPE 1
PLAN
ELEVATION
SECTION A
UP
UP 1200 MIN(1:8 MAX)
100 ROAD PAVEMENTPATHWAY
NOTES:
1. THE KERB RAMP SHOULD BE ALIGNED IN THE DIRECTION OF TRAVEL.2. EDGE OF RAMP SHALL BE FLUSH WITH ROAD PAVEMENT (ASPHALT
OR SEAL).3. CONCRETE STRENGTH TO BE 25MPa COMPRESSIVE STRENGTH AT 28
DAYS. MAXIMUM AGGREGATE SIZE 14mm AND SLUMP OF 75mm.4. ALL CONCRETE SHALL BE BROOM FINISHED ACROSS THE DIRECTION
OF PEDESTRIAN TRAFFIC TO PROVIDE A NON-SLIP FINISH.5. TACTILE GROUND SURFACE INDICATORS SHOULD BE PROVIDED AND
INSTALLED AS PER AS 1428.4.
LAND
ING
1500
MIN
EXPANSION JOINT.KERB.
EXPANSION JOINT.KERB. RAMP.
TACTILE GROUNDSURFACE INDICATORS.
RAMP 1200 MIN (1:8
MAX)
10
1010
SCALE: 1:2EXPANSION JOINT DETAIL
BUTYL-MASTICPOLYMER SEALANT.
FOAM OR POLYTHENEBACKING.
EXPANSION GAP.
CONCRETE.
THIS DRAWING IS NOT TO BEUSED FOR CONSTRUCTION
UNLESS SIGNED AS APPROVED
102 NORTH ROAD, YAKAMIA WA 6330PO BOX 484 ALBANY WA 6331
Tel: (08) 9841 9333Fax: (08) 9841 4099
Email: [email protected]: www.albany.wa.gov.au 0
SHEET No
PROJECT
DRAWING NAME
DRAWING No
-FILE REF
DESIGNED
-JOB No
-SCALE
DRAWNAUTHORISED
DESCRIPTION APPROVED DATE
REV
REV
\\albany.city\data\works & services\city engineering\engineering\04 drafting\__city of albany autocad files\coa standard drawings\coa std drawings.dwg
APPROVED0 APPROVED DK 26/06/18 CITY OF ALBANY ENGINEERING SERVICESSTANDARD CONSTRUCTION DRAWINGS
PEDESTRIAN RAMP - TYPE 1STD-03-031:50 @ A3
JLP
SCALE: 1:25
TYPICAL ASPHALT PATHWAYTO BACK OF KERB
EXISTING KERBAND PAVEMENT. 25mm ASPHALT
PATH WIDTH VARIES
2.0%
25mm ASPHALT
PATH WIDTH VARIES
2.0%
200SHOULDER
200SHOULDER
200SHOULDER
SUBGRADE COMPACTED TO 95% MMDDTO A DEPTH OF 250mm.
150mm GRAVEL BASECOURSECOMPACTED TO 98% MMDD.
SUBGRADE COMPACTED TO 95% MMDDTO A DEPTH OF 250mm.
150mm GRAVEL BASECOURSECOMPACTED TO 98% MMDD.
SCALE: 1:25TYPICAL ASPHALT PATHWAY
150x25 JARRAHEDGING BOARD.
150mm GRAVEL BASECOURSE.
25mm ASPHALT.
SCALE: 1:10TIMBER EDGING DETAIL
THIS DRAWING IS NOT TO BEUSED FOR CONSTRUCTION
UNLESS SIGNED AS APPROVED
102 NORTH ROAD, YAKAMIA WA 6330PO BOX 484 ALBANY WA 6331
Tel: (08) 9841 9333Fax: (08) 9841 4099
Email: [email protected]: www.albany.wa.gov.au 0
SHEET No
PROJECT
DRAWING NAME
DRAWING No
-FILE REF
DESIGNED
-JOB No
-SCALE
DRAWNAUTHORISED
DESCRIPTION APPROVED DATE
REV
REV
\\albany.city\data\works & services\city engineering\engineering\04 drafting\__city of albany autocad files\coa standard drawings\coa std drawings.dwg
APPROVED0 APPROVED DK 26/06/18 CITY OF ALBANY ENGINEERING SERVICESSTANDARD CONSTRUCTION DRAWINGS
CONCRETE PATHWAY DETAILSSTD-03-011:25 @ A3
JLP
NOTES:
1. ALL BITUMEN PRODUCTS SHALL COMPLY WITH THE FOLLOWINGRELEVANT STANDARDS
- AS2008-1997 RESIDUAL BITUMEN FOR PAVEMENTS.- AS2150-2005 HOT MIX ASPHALT - A GUIDE TO GOOD PRACTICE.- AS1160-1996 BITUMEN EMULSIONS FOR THE CONSTRUCTION ANDMAINTENANCE OF PAVEMENTS.
500
(TYP
)
STEP IRONS FACINGONCOMING TRAFFIC.
A-
A-
PLAN
℄ OF
LINER
ASPHALTIC CONCRETE SEAL.
COMPACTED GRAVELBASECOURSE.
PRECAST CONCRETE BASE SLAB.
ALL PIPES TO BE FINISHEDWITH MORTAR FILLET.50mm INSIDE, 100mm OUTSIDE
MORTAR BEDDINGAND FILLET.
FOR LINER SIZE REFERTO 'TABLE A'.
NOMINAL 14mm AGGREGATEFILLED WEEP HOLE ONGEOTEXTILE SHEET.
GEOTEXTILE WRAPTO BASE OF PIT
2.0%
SECTION A-A
EXPANSION JOINT (TYP).
HAND FORM KERB.
TRAFFICABLE 'WAVE GRATE' ORSIMILAR APPROVED CYCLE-SAFEGRATE WITH GALVINISED LOCKDOWN BOLTS.
NOTE: STEP IRONS TO BE INSTALLED WHERE DEPTH IS GREATERTHAN 1000mm FROM COVER TO BASE @300mm CENTRES.
BOTTOM STEP 300mm ABOVE BASE. STEP IRONS ARE TO BEBOLTED ON THE WALL FACING ONCOMING TRAFFIC.
PIPE SIZE ∅
225 - 450
525 - 600
TABLE A
DN1050
DN1200
LINER TO BE SPUNCONCRETE WITH
INTERLOCKING JOINTS
SCALE: 1:25COMBINATION SIDE ENTRY PIT
FOAM JOINT (TYP).
THIS DRAWING IS NOT TO BEUSED FOR CONSTRUCTION
UNLESS SIGNED AS APPROVED
102 NORTH ROAD, YAKAMIA WA 6330PO BOX 484 ALBANY WA 6331
Tel: (08) 9841 9333Fax: (08) 9841 4099
Email: [email protected]: www.albany.wa.gov.au 0
SHEET No
PROJECT
DRAWING NAME
DRAWING No
-FILE REF
DESIGNED
-JOB No
-SCALE
DRAWNAUTHORISED
DESCRIPTION APPROVED DATE
REV
REV
\\albany.city\data\works & services\city engineering\engineering\04 drafting\__city of albany autocad files\coa standard drawings\coa std drawings.dwg
APPROVED0 APPROVED DK 26/06/18 CITY OF ALBANY ENGINEERING SERVICESSTANDARD CONSTRUCTION DRAWINGS
COMBINATION SIDE ENTRY PITSTD-01-031:25 @ A3
JLP
A-
A-
PLAN
TRAFFICABLE 'WAVE GRATE' ORSIMILAR APPROVED CYCLE-SAFEGRATE WITH GALVINISED LOCKDOWN BOLTS.
EXPANSION JOINT.
EXPANSION JOINT.
2.0%
℄ OF
LINER
SECTION A-A
ASPHALTIC CONCRETE SEAL.
COMPACTED GRAVELBASECOURSE.
PRECAST CONCRETE BASE SLAB.
ALL PIPES TO BE FINISHEDWITH MORTAR FILLET.50mm INSIDE, 100mm OUTSIDE
MORTAR BEDDINGAND FILLET.
FOR LINER SIZE REFERTO 'TABLE A'.
NOMINAL 14mm AGGREGATEFILLED WEEP HOLE ONGEOTEXTILE SHEET.
GEOTEXTILE WRAPTO BASE OF PIT
CAST INSITU KERB FLUSHTO BACK OF GULLY FRAME.
TRAFFICABLE 'WAVE GRATE' OR SIMILARAPPROVED CYCLE-SAFE GRATE RAISED25mm FOR ASPHALTIC CONCRETE AND100mm FOR BRICK PAVING.
PIPE SIZE ∅
225 - 450
525 - 600
TABLE A
DN1050
DN1200
LINER TO BE SPUNCONCRETE WITH
INTERLOCKING JOINTS
SCALE: 1:25GRATED GULLY PIT
NOTE: STEP IRONS TO BE INSTALLED WHERE DEPTH IS GREATERTHAN 1000mm FROM COVER TO BASE @300mm CENTRES.
BOTTOM STEP 300mm ABOVE BASE. STEP IRONS ARE TO BEBOLTED ON THE WALL FACING ONCOMING TRAFFIC.
THIS DRAWING IS NOT TO BEUSED FOR CONSTRUCTION
UNLESS SIGNED AS APPROVED
102 NORTH ROAD, YAKAMIA WA 6330PO BOX 484 ALBANY WA 6331
Tel: (08) 9841 9333Fax: (08) 9841 4099
Email: [email protected]: www.albany.wa.gov.au 0
SHEET No
PROJECT
DRAWING NAME
DRAWING No
-FILE REF
DESIGNED
-JOB No
-SCALE
DRAWNAUTHORISED
DESCRIPTION APPROVED DATE
REV
REV
\\albany.city\data\works & services\city engineering\engineering\04 drafting\__city of albany autocad files\coa standard drawings\coa std drawings.dwg
APPROVED0 APPROVED DK 26/06/18 CITY OF ALBANY ENGINEERING SERVICESSTANDARD CONSTRUCTION DRAWINGS
GRATED GULLY PITSTD-01-041:25 @ A3
JLP
290
300
130
3075
25
5 5
125
250
175
100
50
125
50
175
250
75 150 25
150
25
25
300
150
125
R10
R25
SCALE: 1:5
MOUNTABLE KERB (TYPE 2)
R25R10
R25
SCALE: 1:5
SEMI-MOUNTABLE KERB (TYPE 2)
R10R25
R60
3 N10 BARS @ 100mm CRS. LOCATEDCENTRALLY WHERE REQUIRED.
R10
R10
SCALE: 1:5
BARRIER KERB (TYPE 2)SCALE: 1:5
FLUSH KERB (TYPE 2)
25mm ASPHALTSEAL.
25mm ASPHALTSEAL.
25mm ASPHALTSEAL.
10
1010
SCALE: 1:2EXPANSION JOINT DETAIL
BUTYL-MASTICPOLYMER SEALANT.
FOAM OR POLYTHENEBACKING.
EXPANSION GAP.
CONCRETE.
SCALE: 1:5TYPICAL KERB KEYING
250x100 CONCRETEKEY.
TYPICAL KERBPROFILES.
THIS DRAWING IS NOT TO BEUSED FOR CONSTRUCTION
UNLESS SIGNED AS APPROVED
102 NORTH ROAD, YAKAMIA WA 6330PO BOX 484 ALBANY WA 6331
Tel: (08) 9841 9333Fax: (08) 9841 4099
Email: [email protected]: www.albany.wa.gov.au 0
SHEET No
PROJECT
DRAWING NAME
DRAWING No
-FILE REF
DESIGNED
-JOB No
-SCALE
DRAWNAUTHORISED
DESCRIPTION APPROVED DATE
REV
REV
\\albany.city\data\works & services\city engineering\engineering\04 drafting\__city of albany autocad files\coa standard drawings\coa std drawings.dwg
APPROVED0 APPROVED DK 26/06/18 CITY OF ALBANY ENGINEERING SERVICESSTANDARD CONSTRUCTION DRAWINGS
TYPE 2 KERB PROFILES - 25mm ASPHALTSTD-02-021:25 @ A3
JLP
NOTES:
1. CONCRETE FOR KERBING SHALL CONFORM TO AS 1379-1991.2. MINIMUM COMPRESSIVE STRENGTH 25MPa AT 28 DAYS.3. MAXIMUM AGGREGATE SIZE 14mm.4. MAXIMUM SLUMP 75mm.5. KEYED KERBING SHALL BE PROVIDED WHERE RADIUS OF
CURVATURE IS LESS THAN 40m.6. CONTRACTION JOINTS SHALL BE PROVIDED AT 2.0m
CENTRES CONSISTING OF A GROOVE TROWELLED INTO THECONCRETE SURFACE.
7. EVERY ALTERNATE JOINT SHALL BE AN EXPANSION JOINTAND SHALL CONSIST OF A FOAM FILLED, MASTIC GAP,10mm WIDE CUT TO THE FULL DEPTH OF THE KERB.
A-
A-
SCALE: 1:10KERB OUTLET DETAIL
SECTION A-APLAN
MIN
400
COVE
R TO
PIPE
100
600
(MIN)
300x300 CONCRETE ENCASEMENTTO PVC RISER.
∅100 DWV PVC PIPE.
CONCRETE KERB OR PREFABRICATEDSTORMWATER KERB ADAPTOR.
∅100 DWV PVC PIPE CAST INTO CONCRETEKERB OR CONNECTED TO KERB ADAPTOR.
SCREWCAP LID FOR INSPECTION SETINTO PROTECTIVE CONCRETE SURROUND.
NATURAL SURFACE
ROAD SURFACE
SCREWCAP LID
PROTECTIVE CONCRETE SURROUND
KERB
THIS DRAWING IS NOT TO BEUSED FOR CONSTRUCTION
UNLESS SIGNED AS APPROVED
102 NORTH ROAD, YAKAMIA WA 6330PO BOX 484 ALBANY WA 6331
Tel: (08) 9841 9333Fax: (08) 9841 4099
Email: [email protected]: www.albany.wa.gov.au 0
SHEET No
PROJECT
DRAWING NAME
DRAWING No
-FILE REF
DESIGNED
-JOB No
-SCALE
DRAWNAUTHORISED
DESCRIPTION APPROVED DATE
REV
REV
\\albany.city\data\works & services\city engineering\engineering\04 drafting\__city of albany autocad files\coa standard drawings\coa std drawings.dwg
APPROVED0 APPROVED DK 26/06/18 CITY OF ALBANY ENGINEERING SERVICESSTANDARD CONSTRUCTION DRAWINGS
STORMWATER KERB OUTLETSTD-01-071:10 @ A3
JLP
40
290
300
145
3075
40
5
125 125
250
50
190
100
40
140
50
190
245
75 150 20
150
300
150
5
R10
R25
40mm ASPHALTSEAL.
R25R10
R25 40mm ASPHALTSEAL.
R10R25
R60
40mm ASPHALTSEAL.
3 N10 BARS @ 100mm CRS. LOCATEDCENTRALLY WHERE REQUIRED.
R10
R10
SCALE: 1:5
MOUNTABLE KERB (TYPE 3)SCALE: 1:5
SEMI-MOUNTABLE KERB (TYPE 3)
SCALE: 1:5
BARRIER KERB (TYPE 3)SCALE: 1:5
FLUSH KERB (TYPE 3)10
1010
SCALE: 1:2EXPANSION JOINT DETAIL
BUTYL-MASTICPOLYMER SEALANT.
FOAM OR POLYTHENEBACKING.
EXPANSION GAP.
CONCRETE.
SCALE: 1:5TYPICAL KERB KEYING
250x100 CONCRETEKEY.
TYPICAL KERBPROFILES.
THIS DRAWING IS NOT TO BEUSED FOR CONSTRUCTION
UNLESS SIGNED AS APPROVED
102 NORTH ROAD, YAKAMIA WA 6330PO BOX 484 ALBANY WA 6331
Tel: (08) 9841 9333Fax: (08) 9841 4099
Email: [email protected]: www.albany.wa.gov.au 0
SHEET No
PROJECT
DRAWING NAME
DRAWING No
-FILE REF
DESIGNED
-JOB No
-SCALE
DRAWNAUTHORISED
DESCRIPTION APPROVED DATE
REV
REV
\\albany.city\data\works & services\city engineering\engineering\04 drafting\__city of albany autocad files\coa standard drawings\coa std drawings.dwg
APPROVED0 APPROVED DK 26/06/18 CITY OF ALBANY ENGINEERING SERVICESSTANDARD CONSTRUCTION DRAWINGS
TYPE 3 KERB PROFILES - 40mm ASPHALTSTD-02-031:25 @ A3
JLP
NOTES:
1. CONCRETE FOR KERBING SHALL CONFORM TO AS 1379-1991.2. MINIMUM COMPRESSIVE STRENGTH 25MPa AT 28 DAYS.3. MAXIMUM AGGREGATE SIZE 14mm.4. MAXIMUM SLUMP 75mm.5. KEYED KERBING SHALL BE PROVIDED WHERE RADIUS OF
CURVATURE IS LESS THAN 40m.6. CONTRACTION JOINTS SHALL BE PROVIDED AT 2.0m
CENTRES CONSISTING OF A GROOVE TROWELLED INTO THECONCRETE SURFACE.
7. EVERY ALTERNATE JOINT SHALL BE AN EXPANSION JOINTAND SHALL CONSIST OF A FOAM FILLED, MASTIC GAP,10mm WIDE CUT TO THE FULL DEPTH OF THE KERB.
600
600WIDTH OF DRIVEWAY
(3.0m MIN) 600
A -
PLAN
ELEVATION
UP
UP
KERB.
EXPANSION JOINT. EXPANSION JOINT.
EXPANSION JOINT.KERB.
EXPANSION JOINT.KERB.
DRIVEWAY.
DRIVEWAY.
NOTES:
1. CONCRETE STRENGTH TO BE 25MPa COMPRESSIVE STRENGTHAT 28 DAYS. MAXIMUM AGGREGATE SIZE 14mm AND SLUMP OF75mm.
2. CONCRETE APRON TO HAVE A DEEP BROOM FINISH (2mm) WITHA SMOOTH EDGE APPROX 75mm WIDE AT EDGES ANDEXPANSION JOINTS.
3. EXPANSION JOINT PACKING MATERIAL TO EXTEND 50MMBELOW BASE OF PATH AND 10MM OUT OF SIDES TO ENSURECOMPLETE SEPARATION OF PANELS.
4. F62 STEEL REINFORCING MESH REQUIRED INCOMMERCIAL/INDUSTRIAL & HEAVY INDUSTRIAL APRONS ONLY.REFER TO CITY OF ALBANY ENGINEERING SERVICES STANDARDCONSTRUCTION DRAWING STD-05-01 FOR CROSSOVER DETAILS.
SCALE: 1:50CONCRETE APRON
NOTE: CONCRETE APRONS ARE NOT REQUIRED IN AREAS WHEREMOUNTABLE KERBING HAS BEEN USED.
10
1010
SCALE: 1:2EXPANSION JOINT DETAIL
BUTYL-MASTICPOLYMER SEALANT.
FOAM OR POLYTHENEBACKING.
EXPANSION GAP.
CONCRETE.
ROAD PAVEMENTDRIVEWAY.
30100
250
600
SECTION A
NOTES:
1. CONCRETE STRENGTH TO BE 25MPa COMPRESSIVE STRENGTHAT 28 DAYS. MAXIMUM AGGREGATE SIZE 14mm AND SLUMP OF75mm.
2. CONCRETE APRON TO HAVE A DEEP BROOM FINISH (2mm) WITHA SMOOTH EDGE APPROX 75mm WIDE AT EDGES ANDEXPANSION JOINTS.
3. EXPANSION JOINT PACKING MATERIAL TO EXTEND 50MMBELOW BASE OF PATH AND 10MM OUT OF SIDES TO ENSURECOMPLETE SEPARATION OF PANELS.
4. F62 STEEL REINFORCING MESH REQUIRED INCOMMERCIAL/INDUSTRIAL & HEAVY INDUSTRIAL APRONS ONLY.REFER TO CITY OF ALBANY ENGINEERING SERVICES STANDARDCONSTRUCTION DRAWING STD-05-01 FOR CROSSOVER DETAILS.
THIS DRAWING IS NOT TO BEUSED FOR CONSTRUCTION
UNLESS SIGNED AS APPROVED
102 NORTH ROAD, YAKAMIA WA 6330PO BOX 484 ALBANY WA 6331
Tel: (08) 9841 9333Fax: (08) 9841 4099
Email: [email protected]: www.albany.wa.gov.au 0
SHEET No
PROJECT
DRAWING NAME
DRAWING No
-FILE REF
DESIGNED
-JOB No
-SCALE
DRAWNAUTHORISED
DESCRIPTION APPROVED DATE
REV
REV
\\albany.city\data\works & services\city engineering\engineering\04 drafting\__city of albany autocad files\coa standard drawings\coa std drawings.dwg
APPROVED0 APPROVED DK 26/06/18 CITY OF ALBANY ENGINEERING SERVICESSTANDARD CONSTRUCTION DRAWINGS
CONCRETE APRONSTD-02-041:25 @ A3
JLP
2000
500CROSSOVER
WIDTH 500
SCALE: 1:100PLAN
PROPERTY BOUNDARY
COUN
CIL
VERG
E WIDTH
VAR
IES
A -A -
EXISTING ROAD2500
2.0% 2-4%
SCALE: 1:50SECTION A-A
PROP
ERTY
BOU
NDAR
Y
25mm ASPHALT SEAL.
EXISTING SUBGRADE COMPACTED TO95% MMDD TO A DEPTH OF 250mm.
SUB-BASE COMPACTED TO 98% MMDD.REFER TO TABLE FOR DETAILS.
MINIMUM WIDTH@ BOUNDARYCROSSOVER CLASS
3.0m1 OR 2 DWELLINGSON A SINGLE LOT
MAXIMUM WIDTH@ BOUNDARY
6.0m
MAXIMUM WIDTH@ ROAD
7.0m
ALLOWABLE CROSSOVER DIMENSIONS
3.0mSINGLE RESIDENTIALON HIGHWAY OR MRD 6.0m 7.0m
3.0mGROUPED DWELLINGS3 OR MORE 7.5m 7.5m
5.5mCOMMERCIAL
LIGHT INDUSTRIAL
6.0mHEAVY INDUSTRIAL 10.0m 10.0m
7.5mSERVICE STATIONS
7.5m 7.5m
5.5m 7.5m 7.5m
10.0m 10.0m
DOMESTIC
COMMERCIAL/INDUSTRIAL
HEAVY INDUSTRIAL
75mm
SUB-BASETHICKNESS ON SAND
100mm
125mm
CROSSOVER CONSTRUCTION DETAILS
100mm
SUB-BASETHICKNESS ON CLAY
125mm
150mm
CROSSOVER TYPE150x25 JARRAHEDGING BOARD. 150mm GRAVEL BASE
COURSE.
25mm ASPHALT.
SCALE: 1:20TIMBER EDGING DETAIL
THIS DRAWING IS NOT TO BEUSED FOR CONSTRUCTION
UNLESS SIGNED AS APPROVED
102 NORTH ROAD, YAKAMIA WA 6330PO BOX 484 ALBANY WA 6331
Tel: (08) 9841 9333Fax: (08) 9841 4099
Email: [email protected]: www.albany.wa.gov.au 0
SHEET No
PROJECT
DRAWING NAME
DRAWING No
-FILE REF
DESIGNED
-JOB No
-SCALE
DRAWNAUTHORISED
DESCRIPTION APPROVED DATE
REV
REV
\\albany.city\data\works & services\city engineering\engineering\04 drafting\__city of albany autocad files\coa standard drawings\coa std drawings.dwg
APPROVED0 APPROVED DK 26/06/18 CITY OF ALBANY ENGINEERING SERVICESSTANDARD CONSTRUCTION DRAWINGS
STANDARD CROSSOVER - ASPHALTSTD-05-02AS SHOWN
JLP
NOTES:
1. CROSSOVER TO GRADE UP @ 2.0% FROM BACK OFCONCRETE APRON OR MOUNTABLE KERB FOR ADISTANCE OF 2.5m.
2. FOR CROSSOVERS CONSTRUCTED ON NON KERBED ROADSASSUME KERB IN PLACE WHEN ESTABLISHING LEVELS.
3. WHERE THERE IS AN EXISTING PATHWAY IN VERGEREFER TO THE SPECIFICATION FOR DETAILS.
4. FOR CROSSOVERS THAT DO NOT CONFORM TO THESESTANDARD LEVELS CONTACT CITY OF ALBANY FORFURTHER DETAILS.
2.0%
100mm CONCRETE
PATH WIDTH VARIES
SUBGRADE COMPACTED TO 95% MMDDTO A DEPTH OF 250mm.
EXISTING KERBAND PAVEMENT.
2.0%
100mm CONCRETE
PATH WIDTH VARIES
SUBGRADE COMPACTED TO 95% MMDDTO A DEPTH OF 250mm.
EXPANSION JOINT.
SCALE: 1:25
TYPICAL CONCRETE PATHWAYTO BACK OF KERB
SCALE: 1:25TYPICAL CONCRETE PATHWAY
SCALE: 1:10LOCK JOINT DETAIL
CONCRETE PATH.
3mm RECYCLEDP.V.C. JOINT STRIP.
50
12
SCALE: 1:10PATHWAY EXPANSION JOINT DETAIL
CONCRETE PATHWAY.
FOAM OR POLYURETHANEFILLER.
THIS DRAWING IS NOT TO BEUSED FOR CONSTRUCTION
UNLESS SIGNED AS APPROVED
102 NORTH ROAD, YAKAMIA WA 6330PO BOX 484 ALBANY WA 6331
Tel: (08) 9841 9333Fax: (08) 9841 4099
Email: [email protected]: www.albany.wa.gov.au 0
SHEET No
PROJECT
DRAWING NAME
DRAWING No
-FILE REF
DESIGNED
-JOB No
-SCALE
DRAWNAUTHORISED
DESCRIPTION APPROVED DATE
REV
REV
\\albany.city\data\works & services\city engineering\engineering\04 drafting\__city of albany autocad files\coa standard drawings\coa std drawings.dwg
APPROVED0 APPROVED DK 26/06/18 CITY OF ALBANY ENGINEERING SERVICESSTANDARD CONSTRUCTION DRAWINGS
CONCRETE PATHWAY DETAILSSTD-03-011:25 @ A3
JLP
NOTES:
1. CONCRETE STRENGTH TO 25Mpa COMPRESSIVE STRENGTH AT 28 DAYS.MAXIMUM AGGREGATE SIZE 14mm AND MAX SLUMP OF 75mm.
2. PATHWAY TO HAVE A DEEP BROOM FINISH (2mm) WITH A SMOOTH EDGEAPPROX 75mm WIDE AT EDGES AND EXPANSION JOINTS. THERE IS TOBE NO SMOOTH EDGE AT LOCK JOINTS.
3. LOCK JOINT SPACING NOT TO EXCEED 1.5 x PATHWAY WIDTH.4. EXPANSION JOINTS TO BE INSTALLED AT 50m SPACING ON STRAIGHTS,
AT THE START AND END OF CURVES, WHERE PATH CONNECTS ANOTHERPATH OR KERB, BETWEEN BACK OF KERB AND EDGE OF PATH, ANDWHERE PATH ABUTS A BUILDING OR IN-GROUND INFRASTRUCTURE.
5. PATHWAY EXPANSION JOINTS TO ALIGN WITH KERB EXPANSION JOINTS.6. EXPANSION JOINT PACKING MATERIAL TO EXTEND 50mm BELOW BASE
OF PATH AND 10mm OUT OF SIDES TO ENSURE COMPLETE SEPARATIONOF PANELS.
A -
RAMP 1200 MIN (1:8
MAX)
WIDTH OF PATHWAY 600600
KERB.
EXPANSION JOINT. EXPANSION JOINT.
SCALE: 1:50PEDESTRIAN RAMP - TYPE 2
PLAN
ELEVATION
SECTION A
UP 1200 MIN(1:8 MAX)
100 ROAD PAVEMENTPATHWAY
NOTES:
1. THE KERB RAMP SHOULD BE ALIGNED IN THE DIRECTION OF TRAVEL.2. EDGE OF RAMP SHALL BE FLUSH WITH ROAD PAVEMENT (ASPHALT
OR SEAL).3. CONCRETE STRENGTH TO BE 25MPa COMPRESSIVE STRENGTH AT 28
DAYS. MAXIMUM AGGREGATE SIZE 14mm AND SLUMP OF 75mm.4. ALL CONCRETE SHALL BE BROOM FINISHED ACROSS THE DIRECTION
OF PEDESTRIAN TRAFFIC TO PROVIDE A NON-SLIP FINISH.5. TACTILE GROUND SURFACE INDICATORS SHOULD BE PROVIDED AND
INSTALLED AS PER AS 1428.4.
LAND
ING
1500
MIN
EXPANSION JOINT.KERB.
EXPANSION JOINT.KERB. RAMP.
UP
TACTILE GROUNDSURFACE INDICATORS.
10
1010
SCALE: 1:2EXPANSION JOINT DETAIL
BUTYL-MASTICPOLYMER SEALANT.
FOAM OR POLYTHENEBACKING.
EXPANSION GAP.
CONCRETE.
THIS DRAWING IS NOT TO BEUSED FOR CONSTRUCTION
UNLESS SIGNED AS APPROVED
102 NORTH ROAD, YAKAMIA WA 6330PO BOX 484 ALBANY WA 6331
Tel: (08) 9841 9333Fax: (08) 9841 4099
Email: [email protected]: www.albany.wa.gov.au 0
SHEET No
PROJECT
DRAWING NAME
DRAWING No
-FILE REF
DESIGNED
-JOB No
-SCALE
DRAWNAUTHORISED
DESCRIPTION APPROVED DATE
REV
REV
\\albany.city\data\works & services\city engineering\engineering\04 drafting\__city of albany autocad files\coa standard drawings\coa std drawings.dwg
APPROVED0 APPROVED DK 26/06/18 CITY OF ALBANY ENGINEERING SERVICESSTANDARD CONSTRUCTION DRAWINGS
PEDESTRIAN RAMP - TYPE 2STD-03-041:50 @ A3
JLP