Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
SHEET
NO.
CITY OF MARATHONROADWAY IMPROVEMENT PLANS
MONROE COUNTY
AVENUE L
PLANS PREPARED BY:
NOTE: THE SCALE OF THESE PLANS MAY
HAVE CHANGED DUE TO REPRODUCTION.
PROJECT LOCATION
0 2
Miles
1
N
UTILITY PLANS
PROFESSIONAL OF RECORD: CLAIR WRIGHT III, P.E.
P.E. NO.: 64089
KEY SHEET REVISIONS
DATE DESCRIPTION
INDEX OF UTILITY PLANS
SHEET NO. SHEET DESCRIPTION
01 KEY SHEET
02 TYPICAL SECTION
03 - 04 PLAN AND PROFILE
05 - 07 ROADWAY SECTIONS
08 - 10 UTILITY NOTES AND DETAILS
11 EROSION CONTROL
DAVID DOUGLAS ASSOCIATES, INC.
CIVIL ENGINEERS - LAND PLANNERS - CONTRACT ADMINISTRATORS
1821 Victoria Ave, Fort Myers, Florida 33901
Ph. 239-337-3330
Web: www.ddai-engineers.com
Certificate of Authorization # 7568
H:\_MARATHON-OFFICE-PROJECTS\2014\14-0107 MAL\CADD\DWG\01-14-0107-KEY.DWG 10-13-2015 - 5:09 PMJPANICARO
01
PROJECT LENGTH IS BASED ON ℄ OF CONSTRUCTION
LENGTH OF PROJECT
LINEAR FEET MILES
ROADWAY834.04 0.158
TYPICAL SECTION
AVENUE L
STA. 10+10.96 TO STA. 18+45.00
NEW CONSTRUCTION
OPTIONAL BASE GROUP 4 WITH
TYPE SP 9.5 STRUCTURAL COURSE (TRAFFIC A) (2")
EXISTING GRADE
±1.80
EXISTING GRADE
±5.39 - 5.94
TYPE B STABILIZATION
LBR 40
R/W LINE
R/W LINE
50' R/W
LIMITS OF CONSTRUCTION LIMITS OF CONSTRUCTION
STANDARD CLEARING & GRUBBING (60')
℄ CONSTRUCTION
0.02 0.02
0.06
0.06
2' 10' 10' 2'
PROFILE GRADE
POINT
FUTURE DEVELOPMENT
12"
6.00
5.80
5.80
5.68
5.68
18" THICK RUBBLE RIP-RAP DITCH LINING
W/FILTER FABRIC PER FDOT INDEX 281
FROM TOP OF BANK TO TOE OF SLOPE
SOD SOD
5' TEMP. CONSTRUCTION
EASEMENT
6'
2.8'
RETENTION AREA
6'
2.5'
RETENTION AREA
2'
1'
1.5'
3.70
3.70
4.35
MATCH EXISTING
MATCH EXISTING
4.2'3.2'
1.8'
1
:
3
1
:
2
1
:
3
1
:
1
:
5
1
:
3
CITY OF MARATHON, FLORIDA
ROAD NO. COUNTY PROJECT #
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS
SHEET
NO.
H:\_Marathon-Office-Projects\2014\14-0107 MAL\CADD\DWG\02-14-0107-TYP-SEC.dwg
Jason Panicaro10/13/2015 8:55:34 AM
AVENUE LMONROE 14-0107
DAVID DOUGLAS ASSOCIATES, INC.
CIVIL ENGINEERS - LAND PLANNERS - CONTRACT ADMINISTRATORS
1821 Victoria Ave, Fort Myers, Florida 33901
Ph. 239-337-3330
Web: www.ddai-engineers.com
Certification of Authorization # 7568
Clair Wright III, P.E. # 64089
02
TYPICAL SECTION
R15'
R25'
SAWCUT EXISTING ASPHALT
FOR SMOOTH EDGE AND REMOVAL
10'
10'
STA:10+00.53
OFF:22.76 (LT) PC
STA:10+25.64
OFF:31.34 (RT) PC
STA:10+39.24
OFF:10.00 (RT) PT
STA:10+22.33
OFF:10.00 (LT) PT
START TOE
STA:10+60.00
OFF:19.23 (RT)
START TOE
STA:10+40.00
OFF:19.40 (LT)
STA: 10+65.00
OFF: 19.25' (RT)
FDOT TYPE "E" (DBI)
CONTROL STRUCTURE
(STEEL GRATE ONLY)
GE:4.20
03
IE:2.20(SE)
STA: 10+18.24
OFF: 31.24' (LT)
1:4 MES FDOT INDEX 273
04
IE:2.20(NE)
STA: 10+47.14
OFF: 28.67' (RT)
1:4 MES FDOT INDEX 273
05
IE:2.20(SW)
58 LF-14"X23" ERCP
STA: 10+58.92
OFF: 29.45' (RT)
1:4 MES FDOT INDEX 273
06
IE:2.20(NW)
7 LF-14"X23" ERCP
10+00 11+00 12+00 13+00 14+00 15+00
AVENUE L
BEGIN PROJECT CONSTRUCTION
STA:10+10.96
CONTRACTOR TO ADJUST
EXISTING VALVE
N0° 00' 00.00"E
PROP. 4" PVC SDR 21
VACUUM SANITARY SEWER LINE
5' TEMPORARY CONSTRUCTION
EASEMENT (TYP)
RUBBLE RIP-RAP (TYP)
SEE ROADWAY CROSS SECTIONS
REMOVE EXISTING 4" END CAP
AND TIE INTO EXISTING 4"
VACUUM SEWER
CONTRACTOR TO FIELD VERIFY
LOCATION OF CAP AND VALVE
40 LF 3" SDR 21 PVC
VACUUM SEWER
LATERAL
(SINGLE SERVICE)
SEE MAIN CONNECTION
DETAILS FOR CONNECTION OPTIONS
STA:12+76.06
OFF:13.71 (RT)
SEE MAIN CONNECTION
DETAILS FOR CONNECTION OPTIONS
STA:14+95.76
OFF:14.00 (RT)
VALVE PIT (VP1)
W/3 LF 6" SDR26 PVC STUB
W/CLEANOUT (RESIDENTIAL SIDE PLUGGED)
STA:11+57.69
OFF:26.79 (LT)
INV. EL 3.7'
39 LF 3" SDR 21 PVC
VACUUM SEWER LATERAL
(DOUBLE SERVICE)
BEGIN RIP RAP
STA:10+67.57
OFF:23.50 (RT)
VALVE PIT (VP2)
W/3 LF (EACH SIDE) 6" SDR26 PVC STUB
W/CLEANOUT (RESIDENTIAL SIDE PLUGGED)
STA:12+78.45
OFF:26.80 (LT)
INV. EL 3.7'
STA:10+16.62
OFF:13.05 (LT)
12 LF 24" WHITE TRAFFIC BAR
AND R1-1 STOP SIGN
SEE MAIN CONNECTION
DETAILS FOR CONNECTION OPTIONS
STA:11+55.00
OFF:14.00 (RT)
5' SUMP X WIDTH OF MES
GRADE TO NATURAL GROUND
MAXIMUM 1:4, ELEVATION TO
MATCH MES FLOW LINE
5' SUMP X WIDTH OF MES GRADE TO NATURAL GROUND
MAXIMUM 1:4, ELEVATION TO MATCH MES FLOW LINE
STA:10+00.00
OFF:0.00
FOUND NAIL AND
DISC LS 4906
STA:11+68.41
OFF:0.00
SET 60d NAIL
STA:12+78.44
OFF:0.00
SET 60d NAIL
STA:13+88.44
OFF:0.00
SET 60d NAIL
MATCHLINE STA 14+60.00
0
2
4
6
8
10
12
14
16
14"X23" ERCP
FDOT TYPE "E" (DBI)
CONTROL STRUCTURE
GE:4.20
03
IE:2.20(SE)
PI 10+10.96
EL 5.77
PI 10+30.96
EL 6.00
11+00 12+00 13+00 14+00
EXISTING GROUND
EXISTING 6" WMEXISTING 4" WM
BEGIN PROJECT CONSTRUCTION
STA:10+10.96
4" SDR 2
1 PVC
VACUUM
SEWER
MAIN @ 0.2
%
STA 12+15
4" VSAN
INV=0.99
SERVICE LATERAL
CONNECTION
STA 12+16
4" VSAN 45° BEND
INV=0.07
45° BEND
EXISTING 4"
GATE VALVE
EXISTING 6"
VACUUM MAIN
SERVICE LATERAL
CONNECTION
1.16%
0.00%
EL. 6.00
EL. 5.25
0
2
4
6
8
10
12
14
16
CITY OF MARATHON, FLORIDA
ROAD NO. COUNTY PROJECT #
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS
SHEET
NO.
H:\_Marathon-Office-Projects\2014\14-0107 MAL\CADD\DWG\03-14-0107-PAP.dwg
Jason Panicaro10/13/2015 9:18:27 AM
AVENUE LMONROE 14-0107
DAVID DOUGLAS ASSOCIATES, INC.
CIVIL ENGINEERS - LAND PLANNERS - CONTRACT ADMINISTRATORS
1821 Victoria Ave, Fort Myers, Florida 33901
Ph. 239-337-3330
Web: www.ddai-engineers.com
Certification of Authorization # 7568
Clair Wright III, P.E. # 64089
03
1" = 40' Horizontal
1" = 4' Vertical
PLAN AND PROFILE
SCALE 1"=40'
10'
10'
STA: 14+88.00
OFF: 19.40' (LT)
FDOT TYPE "E" (DBI)
CONTROL STRUCTURE
(STEEL GRATE ONLY)
GE:5.30
01
IE:2.50(E)
STA: 14+88.00
OFF: 19.25' (RT)
FDOT TYPE "C" INLET
(STEEL GRATE ONLY)
GE:3.70
02
IE:1.60(W)
37 LF-14"X23" ERCP
14+00 15+00 16+00 17+00 18+00 18+53AVENUE L
END PROJECT CONSTRUCTION
STA:18+45.00
END TOE
STA:18+50.00
OFF:19.25 (RT)
END TOE
STA:18+50.00
OFF:19.40 (LT)
N0° 00' 00.00"E
VACUUM SANITARY SEWER LINE
RUBBLE RIP-RAP (TYP)
SEE ROADWAY CROSS SECTIONS
45° BEND
SEE MAIN CONNECTION
DETAILS FOR CONNECTION OPTIONS
STA:14+95.76
OFF:14.00 (RT)
4" X 3" REDUCER
STA:18+30.68
OFF:14.30 (RT)
41 LF 3" SDR 21 PVC
VACUUM SEWER LATERAL
(DOUBLE SERVICE)
41 LF 3" SDR 21 PVC
VACUUM SEWER LATERAL
(DOUBLE SERVICE)
SEE MAIN CONNECTION
DETAILS FOR CONNECTION OPTIONS
STA:17+15.76
OFF:14.00 (RT)
41 LF 3" SDR 21 PVC
VACUUM SEWER
LATERAL
(SINGLE SERVICE)
PROP. 4" PVC SDR 21
VACUUM SANITARY SEWER LINE
END RIP RAP
STA:18+49.52
OFF:24.32 (RT)
GRADE TO EXISTING GROUND
W/ MINIMUM 2' SHOULDER
AND 1:3 OR FLATTER SLOPE
W/CLEANOUT (RESIDENTIAL SIDE PLUGGED)
VALVE PIT (VP3)
W/3 LF (EACH SIDE) 6" SDR26 PVC STUB
W/CLEANOUT (RESIDENTIAL SIDE PLUGGED)
STA:14+98.45
OFF:26.80 (LT)
INV. EL 3.7'
VALVE PIT (VP4)
W/3 LF (EACH SIDE) 6" SDR26 PVC STUB
W/CLEANOUT (RESIDENTIAL SIDE PLUGGED)
STA:17+18.45
OFF:26.80 (LT)
INV. EL 3.7'
VALVE PIT (VP5)
W/3 LF 6" SDR26 PVC STUB
W/CLEANOUT (RESIDENTIAL SIDE PLUGGED)
STA:18+35.99
OFF:26.80 (LT)
INV. EL 3.7'
STA:13+88.44
OFF:0.00
SET 60d NAIL
STA:17+18.48
OFF:0.00
SET 60d NAIL
MATCHLINE STA 14+60.00
0
2
4
6
8
10
12
14
16
FDOT TYPE "E" (DBI)
CONTROL STRUCTURE
GE:5.30
01
IE:2.50(E)
14"X23" ERCP
PI 18+45.00
EL 6.00
15+00 16+00 17+00 18+00
EXISTING GROUND
EXISTING 4" WM
BEGIN PROJECT CONSTRUCTION
STA:18+45.00
SERVICE LATERAL
CONNECTION
SERVICE LATERAL
CONNECTION
STA 18+30
4" X 3" REDUCER
4" SDR 2
1 PVC
VACUUM
SEWER
MAIN @ 0.2
%
STA 12+15
4" VSAN
INV=1.04
STA 12+15
3" VSAN
INV=1.10
EL. 6.00
EL. 5.25
0
2
4
6
8
10
12
14
16
VACUUM MAIN
CITY OF MARATHON, FLORIDA
ROAD NO. COUNTY PROJECT #
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS
SHEET
NO.
H:\_Marathon-Office-Projects\2014\14-0107 MAL\CADD\DWG\04-14-0107-PAP.dwg
Jason Panicaro10/13/2015 9:18:44 AM
AVENUE LMONROE 14-0107
DAVID DOUGLAS ASSOCIATES, INC.
CIVIL ENGINEERS - LAND PLANNERS - CONTRACT ADMINISTRATORS
1821 Victoria Ave, Fort Myers, Florida 33901
Ph. 239-337-3330
Web: www.ddai-engineers.com
Certification of Authorization # 7568
Clair Wright III, P.E. # 64089
04
1" = 40' Horizontal
1" = 4' Vertical
PLAN AND PROFILE
SCALE 1"=40'
11+00.00
-4.0
0.0
4.0
8.0
12.0
0 10 20 30 40 5001020304050
6.00
6.00
0.02
0.06
0.02
0.06
12+00.00
-4.0
0.0
4.0
8.0
12.0
0 10 20 30 40 5001020304050
6.00
6.00
0.02
0.06
0.02
0.06
13+00.00
-4.0
0.0
4.0
8.0
12.0
0 10 20 30 40 5001020304050
6.00
6.00
0.02
0.06
0.02
0.06
4" WM
6" WM
6" WM
℄ CONSTRUCTION
5.16
5.11
5.24
1.64
5.24
5.44
6" WM
4" VACUUM SANITARY
4" VACUUM SANITARY
4" VACUUM SANITARY
Embankment
V(cy)A(sf)V(cy)
Regular Exc.
A(sf)
1" = 10' Horizontal
1" = 5' Vertical
13.011.2
12.815.6
93.2
37.6
43.0
7.7
47.849.4
52.250.3
SHEET TOTAL
317.2168.1
37.67.7
124.025.4
STA.10+10.96
BEGIN CONSTRUCTION STA.10+10.96
CITY OF MARATHON, FLORIDA
ROAD NO. COUNTY PROJECT #
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS
SHEET
NO.
H:\_Marathon-Office-Projects\2014\14-0107 MAL\CADD\DWG\05-14-0107-SEC.dwg
Jason Panicaro10/13/2015 8:56:43 AM
AVENUE LMONROE 14-0107
DAVID DOUGLAS ASSOCIATES, INC.
CIVIL ENGINEERS - LAND PLANNERS - CONTRACT ADMINISTRATORS
1821 Victoria Ave, Fort Myers, Florida 33901
Ph. 239-337-3330
Web: www.ddai-engineers.com
Certification of Authorization # 7568
Clair Wright III, P.E. # 64089
05
ROADWAY CROSS SECTIONS
14+00.00
-4.0
0.0
4.0
8.0
12.0
0 10 20 30 40 5001020304050
6.00
6.00
0.02
0.06
0.02
0.06
15+00.00
-4.0
0.0
4.0
8.0
12.0
0 10 20 30 40 5001020304050
6.00
6.00
0.02
0.06
0.02
0.06
16+00.00
-4.0
0.0
4.0
8.0
12.0
0 10 20 30 40 5001020304050
6.00
6.00
0.02
0.06
0.02
0.06
4" WM
4" WM
4" WM
℄ CONSTRUCTION
5.08
5.24
5.28
4" VACUUM SANITARY
4" VACUUM SANITARY
4" VACUUM SANITARY
Embankment
V(cy)A(sf)V(cy)
Regular Exc.
A(sf)
1" = 10' Horizontal
1" = 5' Vertical
16.316.2
31.07.9
85.4
15.0
44.3
16.0
87.544.5
44.369.5
SHEET TOTAL
217.2158.3
ROADWAY CROSS SECTIONSCITY OF MARATHON, FLORIDA
ROAD NO. COUNTY PROJECT #
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS
SHEET
NO.
H:\_Marathon-Office-Projects\2014\14-0107 MAL\CADD\DWG\06-14-0107-SEC.dwg
Jason Panicaro10/13/2015 8:57:02 AM
AVENUE LMONROE 14-0107
DAVID DOUGLAS ASSOCIATES, INC.
CIVIL ENGINEERS - LAND PLANNERS - CONTRACT ADMINISTRATORS
1821 Victoria Ave, Fort Myers, Florida 33901
Ph. 239-337-3330
Web: www.ddai-engineers.com
Certification of Authorization # 7568
Clair Wright III, P.E. # 64089
06
17+00.00
-4.0
0.0
4.0
8.0
12.0
0 10 20 30 40 5001020304050
6.00
6.00
0.02
0.06
0.02
0.06
18+00.00
-4.0
0.0
4.0
8.0
12.0
0 10 20 30 40 5001020304050
6.00
6.00
0.02
0.06
0.02
0.06
4" WM
4" WM
℄ CONSTRUCTION
5.37
5.22
4" VACUUM SANITARY
4" VACUUM SANITARY
Embankment
V(cy)A(sf)V(cy)
Regular Exc.
A(sf)
1" = 10' Horizontal
1" = 5' Vertical
5.425.5
7.721.4
24.186.7
SHEET TOTAL
36.2130.1
12.143.4
END PROJECT STA.18+53
0.00.0
PROJECT TOTAL
570.6456.5
CITY OF MARATHON, FLORIDA
ROAD NO. COUNTY PROJECT #
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS
SHEET
NO.
H:\_Marathon-Office-Projects\2014\14-0107 MAL\CADD\DWG\07-14-0107-SEC.dwg
Jason Panicaro10/13/2015 8:57:23 AM
AVENUE LMONROE 14-0107
DAVID DOUGLAS ASSOCIATES, INC.
CIVIL ENGINEERS - LAND PLANNERS - CONTRACT ADMINISTRATORS
1821 Victoria Ave, Fort Myers, Florida 33901
Ph. 239-337-3330
Web: www.ddai-engineers.com
Certification of Authorization # 7568
Clair Wright III, P.E. # 64089
07
ROADWAY CROSS SECTIONS
CITY OF MARATHON, FLORIDA
ROAD NO. COUNTY PROJECT #
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS
SHEET
NO.
H:\_Marathon-Office-Projects\2014\14-0107 MAL\CADD\DWG\08-14-0107-DET.dwgJason Panicaro 10/13/2015 8:57:37 AM
AVENUE LMONROE 14-0107
DAVID DOUGLAS ASSOCIATES, INC.
CIVIL ENGINEERS - LAND PLANNERS - CONTRACT ADMINISTRATORS
1821 Victoria Ave, Fort Myers, Florida 33901
Ph. 239-337-3330
Web: www.ddai-engineers.com
Certification of Authorization # 7568
Clair Wright III, P.E. # 64089
08
UTILITY DETAILS
SHOWING UP TO 4 GRAVITY
CONNECTIONS TO SUMP
SECTION 'B'-'B'
SECTION 'A'-A'
R
VACUUM DETAIL
STANDARD DETAIL NO.
2 PIECE VALVE PIT BEDDING AND BACKFILL
VP-6HN.T.S.
R
VACUUM DETAIL
STANDARD DETAIL NO.
VALVE PIT SECTIONS 'A' AND 'B'
VP-5HN.T.S.
FEBRUARY 2008
FEBRUARY 2008
4" OR 6" SDR 21 OR
SCHEDULE 40 PVC PIPE
SEE SPECIFICATIONS
C 3" VACUUM LATERAL
AND AIRVAC VALVE
L
R
VACUUM DETAIL
STANDARD DETAIL NO.
AIRVAC 2 PIECE VALVE PIT - 6' DEEP
VP-1HN.T.S.
MODEL VP3042H
FEBRUARY 2008
NOTE: IN-SUMP BREATHER
NOT SHOWN IN THIS VIEW
FOR CLARITY--SEE ADJACENT
ELEVATION AND PLAN VIEWS
2" SENSOR LINE
3" SUCTION LINE
4" OR 6" GRAVITY STUB-OUT
WITH GLUED CAP (TYP.)
EXISTING GRADE
CONCRETE COLLAR:
FINAL DESIGN BY ENGINEER OF RECORDCAST IRON FRAME AND LID RATED FOR H20
TRAFFIC LOADING
SPIRAL WOUND, H20 LOADING
RATED, FIBERGLASS VALVE PIT.
27" I.D. AT TOP,
36" I.D. AT BOTTOM.
'A'
'A'
'B'
'B'
AIRVAC FLEXIBLE
CONNECTOR
"A"
4" GRAVITY
DIM "A" 1'-6" 1'-7"
6" GRAVITY
VACUUM SEWER MAIN
(DIRECTION OF FLOW
INTO PAPER.)
ANTI-
BUOYANCY
COLLAR
4-1/2"
6'-0 7/8"
C 3" VACUUM LATERAL
AND AIRVAC VALVE
L
AIRVAC 3" VACUUM VALVE
WHEN INSTALLING ANY PIPE THROUGH
NEVER USE PIPE JOINT GREASE.
A GROMMET USE ONLY WATER, MILD
DETERGENT OR SILICONE LUBRICANT.
NOTE:
2'-2 1/4"
6'-0" MIN. LENGTH
GRAVITY STUB-OUT
WITH GLUED CAP
FINISHED GRADE
TYPICAL VALVE
PIT ASSEMBLY
UNDISTURBED SOIL
COMPACTED SELECT FILL
FILL MATERIAL. MAY BE
ANTI-BUOYANCY COLLAR
THE SAME AS ABOVE
SAND OR OTHER SUITABLE
DENSITY OF 110 LBS
MATERIAL WITH MINIMUM
PER CUBIC FOOT.
6" MIN.
COMPACTED GRANULAR BEDDING
FROM BOTTOM OF EXCAVATION
TO CENTER LINE OF GRAVITY
STUB-OUT IN SUITABLE MATERIAL
SUCH AS #57 STONE, CRUSHED
SEA SHELL, "PEA" GRAVEL, DO
NOT BED IN OTHER MATERIAL
WITHOUT AIRVAC APPROVAL
FINISHED GRADE
4" OR 6" GRAVITY STUB-OUT
WITH GLUED CAP (TYP.)
ONE PIECE MOLDED
SUMP ASSEMBLY
4'-5"x 4'-5"x 1/2" FIBERGLASS
ANTI-BUOYANCY COLLAR
1'-11 1/2" 1/2"
+
-
R
VACUUM DETAIL
STANDARD DETAIL NO.
SERVICE LATERAL - UPHILL TO VACUUM MAIN
VSL-1N.T.S.
R
VACUUM DETAIL
STANDARD DETAIL NO.
AIRVAC FLEXIBLE CONNECTOR
VP-10N.T.S.
R
VACUUM DETAIL
STANDARD DETAIL NO.
STANDARD VALVE PIT ORIENTATION
VP-7N.T.S.
5'-0" MIN.
AIRVAC
VALVE PIT
ASSEMBLY
45° ELBOW
(HORIZONTAL)
45° ELBOW
WYE WITH 45°
ELBOW
NOTE:
REFER TO PLAN AND
PROFILE FOR
SERVICE LINE
ORIENTATION AND
DEVIATIONS FROM
STANDARD DETAIL.
45°
VA
CU
UM
M
AIN
FL
OW
5'-0" MIN.
45°
45°
45°
METHOD "B"
METHOD "A"
7'-10 1/4 ±3/4"
3'-4" ±3/4"
3" SCH 40 PVC
COUPLING
3" SPECIAL PVC FLEXIBLE HOSE WITH OD
CONTROLLED TO PIPE TOLERANCES, 1'-6"
MIN. BENDING RADIUS (BY AIRVAC)
3" SDR 21
PVC PIPE
GRADE
45°
VACUUM MAIN
CONNECTION
LIFT (TYP.)
AIRVAC FLEXIBLE
CONNECTOR
(TYP.)
6'-0" MIN. LENGTH
GRAVITY STUB-OUT
WITH GLUED CAP
RIGHT-OF-WAYPRIVATE PROPERTY
3" SERVICE LATERAL
0.20%MINIMUM SLOPE ON 3" SERVICE LATERAL
MINIMUM SLOPE BETWEEN LIFTS
MAXIMUM NUMBER OF LIFTS
MINIMUM DISTANCE, VALVE PIT TO FIRST LIFT
MINIMUM DISTANCE, LAST LIFT TO VACUUM MAIN
3'-0"MAXIMUM LIFT HEIGHT
5
5'-0"
5'-0"
SEE DETAIL NO. VM-4
SERVICE LATERAL NOTES
1'-0"RECOMMENDED LIFT HEIGHT
3" SCH 40 PVC
COUPLING
FOR SLOPE
SEE DETAIL NO. VM-4
MIN 5'-0" @ 0.20% SLOPE
FROM LAST LIFT TO MAIN
MIN 5'-0" @ 0.20% SLOPE FROM
VALVE PIT TO FIRST LIFT
MIN 5'-0", 20'-0" OR
GREATER RECOMMENDED
FEBRUARY 2008 FEBRUARY 2008 FEBRUARY 2008
INITIAL INSTALLATION - TO INSURE PROPER ALIGNMENT
1. FLEXIBLE CONNECTOR LENGTH MAY NOT BE ALTERED. DO NOT CUT PVC PIPE
OR THE FLEXIBLE HOSE.
2. INSERT BEVELED END INTO THE ALIGNMENT PORT ON THE VALVE PIT. PUSH
FLEXIBLE CONNECTOR ALL THE WAY TO THE 3" SUCTION ELBOW IN THE VALVE PIT.
3. TO INSURE PROPER ALIGNMENT, CONNECT THE BEVELED END TO THE 3"
SUCTION ELBOW USING A TEMPORARY SLIP COUPLING. DO NOT GLUE THIS
COUPLING.
AFTER VALVE PIT INSTALLATION IS COMPLETED - TO ALLOW FOR VACUUM TESTING
1. AFTER THE VALVE PIT INSTALLATION IS COMPLETE, INCLUDING BACKFILL,
REMOVE TEMPORARY PVC COUPLING AND CUT THE PVC PIPE TO THE CENTER OF
THE VALVE PIT ±1". GLUE 3" PVC CAP ONTO END OF PVC PIPE.
2. DO NOT CONDUCT MAIN LINE VACUUM TESTING UNTIL THE TEMPORARY
COUPLING HAS BEEN REMOVED AND THE PVC CAP GLUED ON.
SEE AIRVAC INSTALLATION INSTRUCTIONS FOR ADDITIONAL DETAILS
CITY OF MARATHON, FLORIDA
ROAD NO. COUNTY PROJECT #
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS
SHEET
NO.
H:\_Marathon-Office-Projects\2014\14-0107 MAL\CADD\DWG\09-14-0107-DET.dwgJason Panicaro 10/13/2015 8:57:55 AM
AVENUE LMONROE 14-0107
DAVID DOUGLAS ASSOCIATES, INC.
CIVIL ENGINEERS - LAND PLANNERS - CONTRACT ADMINISTRATORS
1821 Victoria Ave, Fort Myers, Florida 33901
Ph. 239-337-3330
Web: www.ddai-engineers.com
Certification of Authorization # 7568
Clair Wright III, P.E. # 64089
09
UTILITY DETAILS
SCH 40 PVC 45° BEND
2'-0"
MIN.
R
VACUUM DETAIL
STANDARD DETAIL NO.
CHANGE IN DIRECTION
VM-3N.T.S.
SCH 40 PVC 45° BEND
NOTE:
1) SCH 40 PVC RIEBER GASKET
FITTINGS ARE ALSO ACCEPTABLE
2) 90° FITTINGS ARE NOT TO BE USED
FOR CHANGES IN DIRECTION
FEBRUARY 2008
SCH 40 OR SDR 21 PVC
VACUUM MAIN
VACUUM BRANCH
WYE ROLLED AT 45°
45° ELBOW
45°
22 1/2° ELBOW
A
45° ELBOW
A
22 1/2° ELBOW
FL
OW
ISOLATION VALVE
VACUUM MAIN
FLOW
45°
VACUUM BRANCH
F
L
O
W
PLAN VIEW
FLOW
WYE ROLLED AT 45°
45° ELBOW
6' MIN. FROM TOP OF LIFT
+
-
6"
45° ELBOW
LIMIT OF ASSEMBLY
A
VACUUM MAIN
VACUUM SEWER BRANCH
45° ELBOW
6 x 6 x 3
10 x 10 x 3
8 x 8 x 3
WYE SIZE
4 x 4 x 3
14 5/8"
10 1/4"
13"
8 7/8"
A B C
2 7/8"
18.97" 1.58'
15.35"
17.82"
14.93"3 23/32"
ED
1.32'
1.48'
F- INVERT
1.24'
PLAN VIEW (A)
SECTION A-A
8 7/8"
10 1/4"
11 21/32"
8 1/4"
14 1/4"
22 1/8"
16 1/8"
14 5/8"
15 1/2"
15 7/8"
16 25/32"
15 1/4"
10 x 10 x 3
10 x 10 x 4
10 x 10 x 6
10 x 10 x 8
6 x 6 x 3
13"
8 x 8 x 4
10 x 10 x 10
8 x 8 x 3
8 x 8 x 6
8 x 8 x 8
A
10 1/4"
WYE SIZE
4 x 4 x 3
6 x 6 x 4
6 x 6 x 6
4 x 4 x 4
2 7/8"
3 3/32"
5 7/32"
6 7/16"
1.03'
1.10'
1.24'
1.37'
12.37"
13.15"
14.92"
16.42"
2 7/8"
3 3/32"
8 1/8"
3 7/8"
5 7/32"
6 7/16"
0.77'9.28"
1.02'
1.78'
0.94'
1.26'
12.26"
21.34"
11.22"
15.09"
15.34" 1.28'
B
2 7/8"
3 3/32"
5 7/32"
3 3/32"
D- INVERT
0.63'
0.78'
0.99'
0.67'
C
8.30"
9.44"
11.93"
8.02"
1. 45° WYE, SOCKET x SOCKET x SOCKET
2. 45° ELL, SOCKET x SOCKET
DIMENSIONS BASED ON SPEARS MANUFACTURING
WYE FITTING
45° ELBOW
6'-0" MINIMUM FROM TOP OF LIFTVACUUM SEWER MAIN
PLAN VIEW (B)
FLOW
(1)
45° ELBOW
ELEVATION (B)
B
A
D
C
(2)
VACUUM SEWER
BRANCH
45° ELBOW
F
L
O
W
ELEVATION
LIMIT OF
ASSEMBLY
MAIN LINE WYE
ROLLED AT 45°
12"-18"
VARIES WITH
LINE SIZE
DIMENSIONS BASED ON SPEARS MANUFACTURING
1. 45 DEG WYE, SOCKET x SOCKET x SOCKET
2. 45 DEG ELL, SOCKET x SOCKET
VACUUM LINE VIEWED
INTO/OUT OF SHEET
BOTTOM OF BRANCH IS
2" MINIMUM ABOVE TOP
OF MAIN
VACUUM
BRANCH
ISOLATION
VALVE
2'-0"
MIN.
2'-0"
MIN.
R
VACUUM DETAIL
STANDARD DETAIL NO.
BRANCH TO MAIN CONNECTION ASSEMBLY - OPTION 1
VMC-1N.T.S.
R
VACUUM DETAIL
STANDARD DETAIL NO.
BRANCH TO MAIN CONNECTION ASSEMBLY - OPTION 3
VMC-3N.T.S.
R
VACUUM DETAIL
STANDARD DETAIL NO.
BRANCH TO MAIN CONNECTION ASSEMBLY - OPTION 2
VMC-2N.T.S.
R
VACUUM DETAIL
STANDARD DETAIL NO.
PREFERRED VALVE PIT TO MAIN CONNECTIONS
VMC-4N.T.S.
FL
OW
6'-0" MINIMUM FROM TOP OF LIFT
FEBRUARY 2008 FEBRUARY 2008FEBRUARY 2008
FEBRUARY 2008
2 7/8"
2 7/8"
2 7/8"
2 7/8"
2 7/8"
2 7/8"
2 7/8"
3 23/32"
3 23/32"
3 23/32"
BOTTOM OF BRANCH IS
2" MINIMUM ABOVE TOP
OF MAIN
VACUUM BRANCH
VACUUM LINE VIEWED
INTO/OUT OF SHEET
MAIN LINE WYE
ROLLED AT 45°
45° ELBOW
SECTION A-A
F
E
D
C
B
A
(2)
(2)
(1)
FLOW FLOW
FL
OW
6' MINIMUM FROM TOP OF LIFT
PLAN VIEW
VACUUM
SEWER MAIN
WYE FITTING (1)
FROM VALVE PIT
3" LATERAL, 2" OR 0.20% FALL
FROM VALVE TO MAIN (MIN.)
45° ELL TURNED TO UP (2)
45° ELL TURNED SIDE (2)
’
” ”
CITY OF MARATHON, FLORIDA
ROAD NO. COUNTY PROJECT #
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS
SHEET
NO.
H:\_Marathon-Office-Projects\2014\14-0107 MAL\CADD\DWG\10-14-0107-DET.dwgJason Panicaro 10/14/2015 10:45:35 AM
AVENUE LMONROE 14-0107
DAVID DOUGLAS ASSOCIATES, INC.
CIVIL ENGINEERS - LAND PLANNERS - CONTRACT ADMINISTRATORS
1821 Victoria Ave, Fort Myers, Florida 33901
Ph. 239-337-3330
Web: www.ddai-engineers.com
Certification of Authorization # 7568
Clair Wright III, P.E. # 64089
10
UTILITY DETAILS
AVENUE L
AVENUE L
CITY OF MARATHON, FLORIDA
ROAD NO. COUNTY PROJECT #
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS
SHEET
NO.
H:\_Marathon-Office-Projects\2014\14-0107 MAL\CADD\DWG\11-14-0107-EROSION.dwg
Jason Panicaro10/14/2015 10:49:02 AM
AVENUE LMONROE 14-0107
DAVID DOUGLAS ASSOCIATES, INC.
CIVIL ENGINEERS - LAND PLANNERS - CONTRACT ADMINISTRATORS
1821 Victoria Ave, Fort Myers, Florida 33901
Ph. 239-337-3330
Web: www.ddai-engineers.com
Certification of Authorization # 7568
Clair Wright III, P.E. # 64089
11
EROSION CONTROL
SCALE 1"=60'
” ”