19
590 S01002 010103 GMU.....L GMU.....U GMU.....D 811 112 201 811 112 301 811 118 221 811 118 321 811 123 221 811 123 321 811 128 221 811 128 321 811 132 221 811 132 321 811 134 221 811 134 321 811 138 201 811 138 301 811 138 401 811 146 221 811 146 321 811 146 421 811 152 201 811 152 301 811 152 401 811 156 221 811 156 321 811 156 421 811 158 221 811 158 321 811 158 421 811 162 201 811 162 301 811 162 401 0.1 0.5 1 2 3 4 6 10 16 20 25 32 A466 822A 466 01 GMB.....L GMB.....U GMB.....D 811 212 201 811 212 301 811 218 221 811 218 321 811 223 221 811 223 321 811 228 221 811 228 321 811 232 221 811 232 321 811 234 221 811 234 321 811 238 201 811 238 301 811 238 401 811 246 221 811 246 321 811 246 421 811 252 201 811 252 301 811 252 401 811 256 221 811 256 321 811 256 421 811 258 221 811 258 321 811 258 421 811 262 201 811 262 301 811 262 401 A466 822A 466 01 : Current ratings of 0.5, 1, 2, 3, 4, 10, 20, and 25 Amps : Current ratings of 0.5, 1, 2, 3, 4, 10, 20, and 25 Amps Circuit breakers Thermal-magnetic Alternating current Series GM DIN 3 Accessories Other characteristics Interrupting capacity Characteristics GMU... 1 pole GMB... 2 poles Spacing 17,6 mm (.693’’) Life, number of cycles (On+Off) Dielectric withstanding voltage Internal resistance Tripping curves S Degree of protection Weight Mechanical shock Ambient temperature Connection Rated voltage V Rated wire size AWG / mm² Part number Part number Adaptor for DIN 1 rail mount Type Part number Type Rating Complete the product type designation by replacing ..... with the desired current rating. For example : GMU 0.5 L GMB 10 U GMT 32 D Other ratings available, consult us. See table 1 on page 591 for current correction factor vs. temperature. Standard blocks. Products with other options are available, example : auxiliary contact. Consult us. Standard blocks. Products with other options are available, example : auxiliary contact. Consult us. According to standard NF-EN 60 898 According to standard I.E.C. 947-2 4 000 2 000 V rms See table 2 on page 591 Curve B : 3 In < S < 5 In - Curve C : 5 In < S < 10 In - Curve D : 10 In < S < 20 In IP 20 .21 lb (94 gr.) 30 g. -5° C to 40° C Ø 4,5 mm max. 240-415 V AC, 50 - 60 Hz screw clamp for 5 AWG (16 mm²) 415 V AC, 50 - 60 Hz screw clamp for 5 AWG (16 mm²) Curve B (1) Curve C (1) Curve D (1) Rated current in Amps Curve B (1) Curve C (1) Curve D (1) Spacing 35,2 mm (1.39’’) 4 000 2 000 V rms See table 2 on page 591 Curve B : 3 In < S < 5 In - Curve C : 5 In < S < 10 In - Curve D : 10 In < S < 20 In IP 20 .42 lb (188 gr.) 30 g. -5° C to 40° C Ø 4,5 mm max. Type Part number 6 000 Amps 10 000 Amps 6 000 Amps 10 000 Amps Note: (1) See Curves on pages 591 and 604.

Circuit breakers GMU GMB Thermal-magnetic 1 pole · 010103 1 gmu 0.5 t 811 118 620 gmu 1 t 811 123 620 gmu 2 t 811 128 620 gmu 3 t 811 132 620 gmu 4 t 811 134 620 gmu 10 t 811 146

Embed Size (px)

Citation preview

Page 1: Circuit breakers GMU GMB Thermal-magnetic 1 pole · 010103 1 gmu 0.5 t 811 118 620 gmu 1 t 811 123 620 gmu 2 t 811 128 620 gmu 3 t 811 132 620 gmu 4 t 811 134 620 gmu 10 t 811 146

590

S01002 010103

GMU.....L GMU.....U GMU.....D811 112 201 811 112 301811 118 221 811 118 321811 123 221 811 123 321811 128 221 811 128 321

811 132 221 811 132 321811 134 221 811 134 321811 138 201 811 138 301 811 138 401811 146 221 811 146 321 811 146 421

811 152 201 811 152 301 811 152 401811 156 221 811 156 321 811 156 421811 158 221 811 158 321 811 158 421811 162 201 811 162 301 811 162 401

0.10.512

34610

16202532

A466 822A 466 01

GMB.....L GMB.....U GMB.....D811 212 201 811 212 301811 218 221 811 218 321811 223 221 811 223 321811 228 221 811 228 321

811 232 221 811 232 321811 234 221 811 234 321811 238 201 811 238 301 811 238 401811 246 221 811 246 321 811 246 421

811 252 201 811 252 301 811 252 401811 256 221 811 256 321 811 256 421811 258 221 811 258 321 811 258 421811 262 201 811 262 301 811 262 401

A466 822A 466 01

: Current ratings of 0.5, 1, 2, 3, 4, 10, 20, and 25 Amps : Current ratings of 0.5, 1, 2, 3, 4, 10, 20, and 25 Amps

Circuit breakersThermal-magneticAlternating currentSeries GM

DIN 3

Accessories

Other characteristics

Interrupting capacity

Characteristics

GMU...1 pole

GMB...2 poles

Spacing 17,6 mm (.693’’)

Life, number of cycles (On+Off)Dielectric withstanding voltageInternal resistanceTripping curves SDegree of protectionWeightMechanical shock

Ambient temperatureConnection

Rated voltage V

Rated wire size AWG / mm²

Part number Part number

Adaptor for DIN 1 rail mount

Type Part number

Type RatingComplete theproduct type

designation byreplacing ..... withthe desired current

rating.For example :GMU 0.5 LGMB 10 UGMT 32 D

Other ratingsavailable,

consult us.

See table 1 onpage 591 for

current correctionfactor vs.

temperature.

Standard blocks. Products with other options are available,example : auxiliary contact. Consult us.

Standard blocks. Products with other options are available,example : auxiliary contact. Consult us.

According to standard NF-EN 60 898

According to standard I.E.C. 947-2

4 0002 000 V rms

See table 2 on page 591Curve B : 3 In < S < 5 In - Curve C : 5 In < S < 10 In - Curve D : 10 In < S < 20 In

IP 20.21 lb (94 gr.)

30 g.

-5° C to 40° CØ 4,5 mm max.

240-415 V AC, 50 - 60 Hz

screw clamp for 5 AWG (16 mm²)

415 V AC, 50 - 60 Hz

screw clamp for 5 AWG (16 mm²)

Curve B (1) Curve C (1) Curve D (1)Rated currentin Amps

Curve B (1) Curve C (1) Curve D (1)

Spacing 35,2 mm (1.39’’)

4 0002 000 V rms

See table 2 on page 591Curve B : 3 In < S < 5 In - Curve C : 5 In < S < 10 In - Curve D : 10 In < S < 20 In

IP 20.42 lb (188 gr.)

30 g.

-5° C to 40° CØ 4,5 mm max.

Type Part number

6 000 Amps

10 000 Amps

6 000 Amps

10 000 Amps

Note: (1) See Curves on pages 591 and 604.

Page 2: Circuit breakers GMU GMB Thermal-magnetic 1 pole · 010103 1 gmu 0.5 t 811 118 620 gmu 1 t 811 123 620 gmu 2 t 811 128 620 gmu 3 t 811 132 620 gmu 4 t 811 134 620 gmu 10 t 811 146

591

: Current ratings of 0.5, 1, 2, 3, 4, 10, 20, and 25 Amps : Current ratings of 0.5, 1, 2, 3, 4, 10, 20, and 25 Amps

S01003 010103

ADAPTATEUR A466PXXX 123 456 78

ADAPTATEUR A466PXXX 123 456 78

GMT.....L GMT.....U GMT.....D811 312 201 811 312 301811 318 221 811 318 321811 323 221 811 323 321811 328 221 811 328 321

811 332 221 811 332 321811 334 221 811 334 321811 338 201 811 338 301 811 338 401811 346 221 811 346 321 811 346 421

811 352 201 811 352 301 811 352 401811 356 221 811 356 321 811 356 421811 358 221 811 358 321 811 358 421811 362 201 811 362 301 811 362 401

GMQ.....L GMQ.....U GMQ.....D811 412 201 811 412 301811 418 221 811 418 321811 423 221 811 423 321811 428 221 811 428 321

811 432 221 811 432 321811 434 221 811 434 321811 438 201 811 438 301 811 438 401811 446 221 811 446 321 811 446 421

811 452 201 811 452 301 811 452 401811 456 221 811 456 321 811 456 421811 458 221 811 458 321 811 458 421811 462 201 811 462 301 811 462 401

A466 822A 466 01 A466 822A 466 01

0.5 4 0001 1 2002 4204 16010 1320 6

Part number Part number

Table 1

Table 2

Current correctionfactor vs. temperature

Ambient Correctiontemperature factor°C °F (multiply by)

- 20 - 4 1.25- 10 + 14 1.20- 5 + 23 1.17- 0 + 32 1.15+ 10 + 50 1.10+ 20 + 68 1.05+ 30 + 86 1.00+ 40 + 104 0.95+ 50 + 122 0.90+ 60 + 140 0.85+ 70 + 158 0.80

Internal resistancevs. current rating

Current Internalrating resistance

(A) (mΩ)

GMT...3 poles

Spacing 52,8 mm (2.08’’)

Standard blocks. Products with other options are available,example : auxiliary contact. Consult us.

Curve B Curve C Curve D

GMQ...4 poles

Spacing 70,4 mm (2.77’’)

Standard blocks. Products with other options are available,example : auxiliary contact. Consult us.

Curve B Curve C Curve D

4 0002 000 V rmsSee table 2

Curve B : 3 In < S < 5 In - Curve C : 5 In < S < 10 In - Curve D : 10 In < S < 20 InIP 20

.62 lb (282 gr.)30 g.

-5° C to 40° CØ 4,5 mm max.

415 V AC, 50 - 60 Hz

screw clamp for 5 AWG (16 mm²)

4 0002 000 V rmsSee table 2

Curve B : 3 In < S < 5 In - Curve C : 5 In < S < 10 In - Curve D : 10 In < S < 20 InIP 20

.83 lb (376 gr.)30 g.

-5° C to 40° CØ 4,5 mm max.

415 V AC, 50 - 60 Hz

screw clamp for 5 AWG (16 mm²)

Type Part number Type Part number

Curve B

Curve C

Curve D

See page 604 for larger scale curves.

Multiples of In (rating)

Tim

e in

sec

ond

s

Multiples of In (rating)

Tim

e in

sec

ond

s

Multiples of In (rating)

Tim

e in

sec

ond

s

6 000 Amps

10 000 Amps

6 000 Amps

10 000 Amps

Page 3: Circuit breakers GMU GMB Thermal-magnetic 1 pole · 010103 1 gmu 0.5 t 811 118 620 gmu 1 t 811 123 620 gmu 2 t 811 128 620 gmu 3 t 811 132 620 gmu 4 t 811 134 620 gmu 10 t 811 146

592

S01004 010103

GM1+N.....L GM1+N.....U GM1 +N.....D811 512 201 811 512 301811 518 201 811 518 301811 523 201 811 523 301811 528 201 811 528 301

811 532 201 811 532 301811 534 201 811 534 301811 538 201 811 538 301 811 538 401811 546 201 811 546 301 811 546 401

811 552 201 811 552 301 811 552 401811 556 201 811 556 301 811 556 401811 558 201 811 558 301 811 558 401811 562 201 811 562 301 811 562 401

0.10.512

34610

16202532

A466 822A 466 01

GM3+N.....L GM3+N.....U GM3+N.....D811 612 201 811 612 301811 618 201 811 618 301811 623 201 811 623 301811 628 201 811 628 301

811 632 201 811 632 301811 634 201 811 634 301811 638 201 811 638 301 811 638 401811 646 201 811 646 301 811 646 401

811 652 201 811 652 301 811 652 401811 656 201 811 656 301 811 656 401811 658 201 811 658 301 811 658 401811 662 201 811 662 301 811 662 401

A466 822A 466 01

Approvals: Contact Entrelec Approvals: Contact Entrelec

Circuit breakersThermal-magneticAlternating currentSeries GM

DIN 3

Accessories

Other characteristics

Interrupting capacity

Characteristics

GM1+N...1 pole + neutral

GM3+N...3 poles + neutral

Spacing 35.2 mm (1.39’’)

Life, number of cycles (On+Off)Dielectric withstanding voltageInternal resistanceTripping curves SDegree of protectionWeightMechanical shock

Ambient temperatureConnection

Rated voltage V

Rated wire size AWG / mm²

Part number Part number

Adaptor for DIN 1 rail mount

Type Part number

Type RatingComplete theproduct type

designation byreplacing ..... withthe desired current

rating.For example :GM1+N 0.5 LGM1+N 10 UGM3+N 32 D

Other ratingsavailable,

consult us.

See table 1 onpage 591 for

current correctionfactor vs.

temperature.

Standard blocks. Products with other options are available,example : auxiliary contact. Consult us.

Standard blocks. Products with other options are available,example : auxiliary contact. Consult us.

According to standard I.E.C. 898

According to standard I.E.C. 947-2

4 0002 000 V rms

See table 2 on page 591Curve B : 3 In < S < 5 In - Curve C : 5 In < S < 10 In - Curve D : 10 In < S < 20 In

IP 20.42 lb (188 gr.)

30 g.

-5° C to 40° CØ 4.5 mm max.

240 V AC, 50 - 60 Hz

screw clamp for 5 AWG (16 mm²)

415 V AC, 50 - 60 Hz

screw clamp for 5 AWG (16 mm²)

Curve B (1) Curve C (1) Curve D (1)Rated currentin Amps

Curve B (1) Curve C (1) Curve D (1)

Spacing 70.4 mm (2.77’’)

4 0002 000 V rms

See table 2 on page 591Curve B : 3 In < S < 5 In - Curve C : 5 In < S < 10 In - Curve D : 10 In < S < 20 In

IP 20.83 lb (376 gr.)

30 g.

-5° C to 40° CØ 4.5 mm max.

Type Part number

6 000 Amps

10 000 Amps

6 000 Amps

10 000 Amps

Note: (1) See Curves on pages 591 and 604.

Page 4: Circuit breakers GMU GMB Thermal-magnetic 1 pole · 010103 1 gmu 0.5 t 811 118 620 gmu 1 t 811 123 620 gmu 2 t 811 128 620 gmu 3 t 811 132 620 gmu 4 t 811 134 620 gmu 10 t 811 146

593

S01005 010103

GZ1+N.....L GZ1+N.....U GZ1+N.....D814 512 201 814 512 301814 518 201 814 518 301814 523 201 814 523 301814 528 201 814 528 301

814 532 201 814 532 301814 534 201 814 534 301814 538 201 814 538 301 814 538 401814 546 201 814 546 301 814 546 401

814 552 201 814 552 301 814 552 401814 556 201 814 556 301 814 556 401814 558 201 814 558 301 814 558 401814 562 201 814 562 301 814 562 401

0.10.512

34610

16202532

A466 822A 466 01 A466 822A 466 01

GZB.....L GZB.....U GZB.....D814 212 201 814 212 301814 218 201 814 218 301814 223 201 814 223 301814 228 201 814 228 301

814 232 201 814 232 301814 234 201 814 234 301814 238 201 814 238 301 814 238 401814 246 201 814 246 301 814 246 401

814 252 201 814 252 301 814 252 401814 256 201 814 256 301 814 256 401814 258 201 814 258 301 814 258 401814 262 201 814 262 301 814 262 401

Circuit breakersThermal-magneticAlternating currentSeries GZ

DIN 3

Accessories

Other characteristics

Interrupting capacity

Characteristics

GZ1+N...1 pole + neutral

GZB...2 poles

Spacing 17,6 mm (.693’’)

Life, number of cycles (On+Off)Dielectric withstanding voltageInternal resistanceTripping curves SDegree of protectionWeightMechanical shock

Ambient temperatureConnection

Rated voltage VRated wire size AWG / mm2

Part number Part number

Adaptor for DIN 1 rail mount

Type Part number

Type RatingComplete theproduct type

designation byreplacing ..... withthe desired current

rating.For example :GZ1+N 0.5 LGZ1+N 10 UGZB 32 D

Other ratingsavailable,

consult us.

See table 1 onpage 591 for

current correctionfactor vs.

temperature.

Standard blocks. Products with other options are available,example : auxiliary contact. Consult us.

Standard blocks. Products with other options are available,example : auxiliary contact. Consult us.

According to standard NF-EN 60 898

According to standard IEC 947-2

4 0002 000 V rms

See table 2 on page 591Curve B : 3 In < S < 5 In - Curve C : 5 In < S < 10 In - Curve D : 10 In < S < 20 In

IP 20.22 lb (99 gr.)

30 g.

-5° C to 40° CØ 4.5 mm max.

240 V AC, 50 - 60 Hzscrew clamp for 5 AWG (16 mm²)

415 V AC, 50 - 60 Hzscrew clamp for 5 AWG (16 mm²)

Curve B (1) Curve C (1) Curve D (1)Rated currentin Amps

Curve B (1) Curve C (1) Curve D (1)

Spacing 17,6 mm (.693’’)

4 0002 000 V rms

See table 2 on page 591Curve B : 3 In < S < 5 In - Curve C : 5 In < S < 10 In - Curve D : 10 In < S < 20 In

IP 20.24 lb (110 gr.)

30 g.

-5° C to 40° CØ 4.5 mm max.

Type Part number

3 000 Amps

4 500 Amps

4 500 Amps

6 000 Amps

Note: (1) See Curves on pages 591 and 604.

Approvals: Contact Entrelec Approvals: Contact Entrelec

Page 5: Circuit breakers GMU GMB Thermal-magnetic 1 pole · 010103 1 gmu 0.5 t 811 118 620 gmu 1 t 811 123 620 gmu 2 t 811 128 620 gmu 3 t 811 132 620 gmu 4 t 811 134 620 gmu 10 t 811 146

594

S01006 010103

0.10.512

34610

16202532

A466 822A 466 01 A466 822A 466 01

GMU 0.1T 811 112 601GMU 0.5 T 811 118 620GMU 1 T 811 123 620GMU 2 T 811 128 620

GMU 3 T 811 132 620GMU 4 T 811 134 620GMU 6 T 811 138 601GMU 10 T 811 146 620

GMU 16 T 811 152 601GMU 20 T 811 156 620GMU 25 T 811 158 620GMU 32 T 811 162 601

GMB 0.1T 811 212 601GMB 0.5 T 811 218 620GMB 1 T 811 223 620GMB 2 T 811 228 620

GMB 3 T 811 232 620GMB 4 T 811 234 620GMB 6 T 811 238 601GMB 10 T 811 246 620

GMB 16 T 811 252 601GMB 20 T 811 256 620GMB 25 T 811 258 620GMB 32 T 811 262 601

Note: (1) See Curves on pages 595 and 605.

: Current ratings of 0.5, 1, 2, 3, 4, 10, 20, and 25 Amps: Current ratings of 0.5, 1, 2, 3, 4, 10, 20, and 25 Amps

Circuit breakersThermalAlternating currentSeries GM

DIN 3

Accessories

Other characteristics

Interrupting capacity

Characteristics

GMU...T1 pole

GMB...T2 poles

Spacing 17,6 mm (.693’’)

Life, number of cycles (On+Off)Dielectric withstanding voltageInternal resistanceTripping curvesDegree of protectionWeightMechanical shock

Ambient temperatureConnection

Rated voltage

Rated wire size AWG / mm²

Adaptor for DIN 1 rail mount

Type Part number

TypeOther ratings

available,consult us.

See table 1 onpage 595 for

current correctionfactor vs.

temperature.

Standard blocks. Products with other options are available,example : auxiliary contact. Consult us.

Standard blocks. Products with other options are available,example : auxiliary contact. Consult us.

4 0002 000 V rms

See table 3 on page 595

IP 20.2 lb (87 gr.)

30 g.

-5° C to 40° CØ 4.5 mm max.

240-415 V AC, 50 - 60 Hz

screw clamp for 5 AWG (16 mm²)

415 V AC, 50 - 60 Hz

screw clamp for 5 AWG (16 mm²)

Curve T (1)Rated currentin Amps

Curve T (1)

Spacing 35,2 mm (1.39’’)

4 0002 000 V rms

See table 3 on page 595

IP 20.38 lb (174 gr.)

30 g.

-5° C to 40° CØ 4.5 mm max.

Type Part number

Type Part number Type Part number

10 In Rating < 5 Amps - 20 In Rating ≥ 5 Amps 10 In Rating < 5 Amps - 20 In Rating ≥ 5 AmpsCurve T

Page 6: Circuit breakers GMU GMB Thermal-magnetic 1 pole · 010103 1 gmu 0.5 t 811 118 620 gmu 1 t 811 123 620 gmu 2 t 811 128 620 gmu 3 t 811 132 620 gmu 4 t 811 134 620 gmu 10 t 811 146

595

S01007 010103

ADAPTATEURA466

ADAPTATEUR A466PXXX 123 456 78

A466 822A 466 01 A466 822A 466 01

GMT 0.1T 811 312 601GMT 0.5 T 811 318 620GMT 1 T 811 323 620GMT 2 T 811 328 620

GMT 3 T 811 332 620GMT 4 T 811 334 620GMT 6 T 811 338 601GMT 10 T 811 346 620

GMT 16 T 811 352 601GMT 20 T 811 356 620GMT 25 T 811 358 620GMT 32 T 811 362 601

GMQ 0.1T 811 412 601GMQ 0.5 T 811 418 620GMQ 1 T 811 423 620GMQ 2 T 811 428 620

GMQ 3 T 811 432 620GMQ 4 T 811 434 620GMQ 6 T 811 438 601GMQ 10 T 811 446 620

GMQ 16 T 811 452 601GMQ 20 T 811 456 620GMQ 25 T 811 458 620GMQ 32 T 811 462 601

0.5 3 0001 1 0002 3504 13010 1020 5

: Current ratings of 0.5, 1, 2, 3, 4, 10, 20, and 25 Amps : Current ratings of 0.5, 1, 2, 3, 4, 10, 20, and 25 Amps

Table 1

Table 3

Current correctionfactor vs. temperature

Ambient Correctiontemperature factor°C °F (multiply by)

- 20 - 4 1.25- 10 + 14 1.20- 5 + 23 1.17- 0 + 32 1.15+ 10 + 50 1.10+ 20 + 68 1.05+ 30 + 86 1.00+ 40 +104 0.95+ 50 +122 0.90+ 60 +140 0.85+ 70 +158 0.80

Internal resistancevs. current rating

Current Internalrating resistance

(A) (mΩ)

GMT...T3 poles

Spacing 52,8 mm (2.08’’)

GMQ...T4 poles

Spacing 70,4 mm (2.77’’)

Standard blocks. Products with other options are available,example : auxiliary contact. Consult us.

415 V AC, 50 - 60 Hz

screw clamp for 5 AWG (16 mm²)

Type Part number Type Part number

Curve T

See page 605 for larger scale curve.

Curve T (1) Curve T (1)

Type Part number Type Part number

4 0002 000 V rmsSee table 3

IP 20.77 lb (348 gr.)

30 g.

-5° C to 40° CØ 4.5 mm max.

10 In Rating < 5 Amps - 20 In Rating ≥ 5 Amps

415 V AC, 50 - 60 Hz

screw clamp for 5 AWG (16 mm²)

4 0002 000 V rmsSee table 3

IP 20.58 lb (261 gr.)

30 g.

-5° C to 40° CØ 4.5 mm max.

Standard blocks. Products with other options are available,example : auxiliary contact. Consult us.

10 In Rating < 5 Amps - 20 In Rating ≥ 5 Amps

Page 7: Circuit breakers GMU GMB Thermal-magnetic 1 pole · 010103 1 gmu 0.5 t 811 118 620 gmu 1 t 811 123 620 gmu 2 t 811 128 620 gmu 3 t 811 132 620 gmu 4 t 811 134 620 gmu 10 t 811 146

596

S01008 010103

0.10.512

34610

16202532

A466 822A 466 01 A466 822A 466 01

GFU 0.1 S 812 112 501GFU 0.5 S 812 118 501GFU 1 S 812 123 501GFU 2 S 812 128 501

GFU 3 S 812 132 501GFU 4 S 812 134 501GFU 6 S 812 138 501GFU 10 S 812 146 501

GFU 16 S 812 152 501GFU 20 S 812 156 501GFU 25 S 812 158 501GFU 32 S 812 162 501

GFB 0.1 S 812 212 501GFB 0.5 S 812 218 501GFB 1 S 812 223 501GFB 2 S 812 228 501

GFB 3 S 812 232 501GFB 4 S 812 234 501GFB 6 S 812 238 501GFB 10 S 812 246 501

GFB 16 S 812 252 501GFB 20 S 812 256 501GFB 25 S 812 258 501GFB 32 S 812 262 501

Approvals: Contact Entrelec Approvals: Contact Entrelec

Circuit breakersThermal-magneticDirect current100 V max.Series GF

DIN 3

Accessories

Other characteristics

Interrupting capacity

Characteristics

GFU...S1 pole

GFB...S2 poles

Spacing 17,6 mm (.693’’)

Life, number of cycles (On+Off)Dielectric withstanding voltage VInternal resistanceTripping curves SDegree of protectionWeightMechanical shock

Ambient temperatureConnection

Rated voltage V

Rated wire size AWG / mm²

Adaptor for DIN 1 rail mount

Type Part number

RatingOther ratings

available,consult us.

Standard blocks. Products with other options are available,example : auxiliary contact. Consult us.

Standard blocks. Products with other options are available,example : auxiliary contact. Consult us.

According to standard NF F62 001

4 0002 000 V rms

See table 2 on page 591Current rating 0.1 to 2 A : 5 In < S < 10 In - 3 to 32 A : 7 In < S < 14 In

IP 20.21 lb (94 gr.)

30 g.

- 25° C to + 70° CØ 4.5 mm max.

100 V DC max.

screw clamp for 5 AWG (16 mm²)

100 V DC max.

screw clamp for 5 AWG (16 mm²)

Rated currentin Amps

Spacing 35,2 mm (1.39’’)

4 0002 000 V rms

See table 2 on page 591Current rating 0.1 to 2 A : 5 In < S < 10 In - 3 to 32 A : 7 In < S < 14 In

IP 20.42 lb (188 gr.)

30 g.

- 25° C to + 70° CØ 4.5 mm max.

Type Part number

Type Part numberType Part number

1 000 Amps 1 000 Amps

Page 8: Circuit breakers GMU GMB Thermal-magnetic 1 pole · 010103 1 gmu 0.5 t 811 118 620 gmu 1 t 811 123 620 gmu 2 t 811 128 620 gmu 3 t 811 132 620 gmu 4 t 811 134 620 gmu 10 t 811 146

597

S01009 010103

0.10.512

34610

16202532

A466 822A 466 01 A466 822A 466 01

GCU 0.1 S 813 112 501GCU 0.5 S 813 118 501GCU 1 S 813 123 501GCU 2 S 813 128 501

GCU 3 S 813 132 501GCU 4 S 813 134 501GCU 6 S 813 138 501GCU 10 S 813 146 501

GCU 16 S 813 152 501GCU 20 S 813 156 501GCU 25 S 813 158 501GCU 32 S 813 162 501

GCB 0.1 S 813 212 501GCB 0.5 S 813 218 501GCB 1 S 813 223 501GCB 2 S 813 228 501

GCB 3 S 813 232 501GCB 4 S 813 234 501GCB 6 S 813 238 501GCB 10 S 813 246 501

GCB 16 S 813 252 501GCB 20 S 813 256 501GCB 25 S 813 258 501GCB 32 S 813 262 501

Approvals: Contact Entrelec Approvals: Contact Entrelec

Circuit breakersThermal-magneticDirect current150 V max.Series GC

DIN 3

Accessories

Other characteristics

Interrupting capacity

Characteristics

GCU...S1 pole

GCB...S2 poles

Spacing 17,6 mm (.693)

Life, number of cycles (On+Off)Dielectric withstanding voltage VInternal resistanceTripping curves SDegree of protectionWeightMechanical shock

Ambient temperatureConnection

Rated voltage V

Rated wire size AWG / mm²

Adaptor for DIN 1 rail mount

Type Part number

RatingOther ratings

available,consult us.

Standard blocks. Products with other options are available,example : auxiliary contact. Consult us.

According to standard NF F62 001

4 0002 000 V rms

See table 2 on page 591Current rating 0.1 to 2 A : 5 In < S < 10 In - 3 to 32 A : 7 In < S < 14 In

IP 20.21 lb (94 gr.)

30 g.

- 25° C to + 70° CØ 4.5 mm max.

150 V DC max.

screw clamp for 5 AWG (16 mm²)

150 V DC max.

screw clamp for 5 AWG (16 mm²)

Rated currentin Amps

Spacing 35,2 mm (1.39’’)

4 0002 000 V rms

See table 2 on page 591Current rating 0.1 to 2 A : 5 In < S < 10 In - 3 to 32 A : 7 In < S < 14 In

IP 20.42 lb (188 gr.)

30 g.

- 25° C to + 70° CØ 4.5 mm max.

Type Part number

Type Part numberType Part number

1 500 Amps 1 500 Amps

Standard blocks. Products with other options are available,example : auxiliary contact. Consult us.

Page 9: Circuit breakers GMU GMB Thermal-magnetic 1 pole · 010103 1 gmu 0.5 t 811 118 620 gmu 1 t 811 123 620 gmu 2 t 811 128 620 gmu 3 t 811 132 620 gmu 4 t 811 134 620 gmu 10 t 811 146

598

S01010 010103

0.10.512

34610

16202532

A466 822A 466 01 A466 822A 466 01

GFU 0.1 T 812 112 601GFU 0.5 T 812 118 601GFU 1 T 812 123 601GFU 2 T 812 128 601

GFU 3 T 812 132 601GFU 4 T 812 134 601GFU 6 T 812 138 601GFU 10 T 812 146 601

GFU 16 T 812 152 601GFU 20 T 812 156 601GFU 25 T 812 158 601GFU 32 T 812 162 601

GFB 0.1 T 812 212 601GFB 0.5 T 812 218 601GFB 1 T 812 223 601GFB 2 T 812 228 601

GFB 3 T 812 232 601GFB 4 T 812 234 601GFB 6 T 812 238 601GFB 10 T 812 246 601

GFB 16 T 812 252 601GFB 20 T 812 256 601GFB 25 T 812 258 601GFB 32 T 812 262 601

Approvals: Contact Entrelec Approvals: Contact Entrelec

Circuit breakersThermalDirect current100 V max.Series GF

DIN 3

Accessories

Other characteristics

Interrupting capacity

Characteristics

GFU...T1 pole

GFB...T2 poles

Spacing 17,6 mm (0.693’’)

Life, number of cycles (On+Off)Dielectric withstanding voltageInternal resistance

Degree of protectionWeightMechanical shock

Ambient temperatureConnection

Rated voltage V

Rated wire size AWG / mm²

Adaptor for DIN 1 rail mount

Type Part number

TypeOther ratings

available,consult us.

See table 1 onpage 595 for

current correctionfactor vs.

temperature.

Standard blocks. Products with other options are available,example : auxiliary contact. Consult us.

Standard blocks. Products with other options are available,example : auxiliary contact. Consult us.

4 0002 000 V rms

See table 3 on page 595

IP 20.2 lb (87 gr.)

30 g.

- 5° C to 40° CØ 4.5 mm. max.

100 V DC max. 100 V DC max.

Curve T (1)Rated currentin Amps

Curve T (1)

Spacing 35,2 mm (1.39’’)

4 0002 000 V rms

See table 3 on page 595

IP 20.38 lb (174 gr.)

30 g.

-5° C to 40° CØ 4.5 mm. max.

Type Part number

Type Part number Type Part number

10 In Rating < 5 Amps - 20 In Rating ≥ 5 Amps 10 In Rating < 5 Amps - 20 In Rating ≥ 5 AmpsCurve T

Note: (1) See Curves on pages 595 and 605.

Page 10: Circuit breakers GMU GMB Thermal-magnetic 1 pole · 010103 1 gmu 0.5 t 811 118 620 gmu 1 t 811 123 620 gmu 2 t 811 128 620 gmu 3 t 811 132 620 gmu 4 t 811 134 620 gmu 10 t 811 146

599

S01011 010103

0.10.512

34610

16202532

A466 822A 466 01 A466 822A 466 01

GCU 0.1 T 813 112 601GCU 0.5 T 813 118 601GCU 1 T 813 123 601GCU 2 T 813 128 601

GCU 3 T 813 132 601GCU 4 T 813 134 601GCU 6 T 813 138 601GCU 10 T 813 146 601

GCU 16 T 813 152 601GCU 20 T 813 156 601GCU 25 T 813 158 601GCU 32 T 813 162 601

GCB 0.1 T 813 212 601GCB 0.5 T 813 218 601GCB 1 T 813 223 601GCB 2 T 813 228 601

GCB 3 T 813 232 601GCB 4 T 813 234 601GCB 6 T 813 238 601GCB 10 T 813 246 601

GCB 16 T 813 252 601GCB 20 T 813 256 601GCB 25 T 813 258 601GCB 32 T 813 262 601

Approvals: Contact Entrelec Approvals: Contact Entrelec

Circuit breakersThermalDirect current150 V max.Series GC

DIN 3

Accessories

Other characteristics

Interrupting capacity

Characteristics

GCU...T1 pole

GCB...T2 poles

Spacing 17,6 mm (0.693’’)

Life, number of cycles (On+Off)Dielectric withstanding voltageInternal resistance

Degree of protectionWeightMechanical shock

Ambient temperatureConnection

Rated voltage V

Rated wire size AWG / mm²

Adaptor for DIN 1 rail mount

Type Part number

TypeOther ratings

available,consult us.

See table 1 onpage 595 for

current correctionfactor vs.

temperature.

Standard blocks. Products with other options are available,example : auxiliary contact. Consult us.

Standard blocks. Products with other options are available,example : auxiliary contact. Consult us.

4 0002 000 V rms

See table 3 on page 595

IP 20.2 lb (87 gr.)

30 g.

- 5° C to 40° CØ 4.5 mm. max.

150 V DC max. 150 V DC max.

Curve T (1)Rated currentin Amps

Curve T (1)

Spacing 35,2 mm (1.39’’)

4 0002 000 V rms

See table 3 on page 595

IP 20.38 lb (174 gr.)

30 g.

-5° C to 40° CØ 4.5 mm. max.

Type Part number

Type Part number Type Part number

10 In Rating < 5 Amps - 20 In Rating ≥ 5 Amps 10 In Rating < 5 Amps - 20 In Rating ≥ 5 AmpsCurve T

Note: (1) See Curves on pages 595 and 605.

Page 11: Circuit breakers GMU GMB Thermal-magnetic 1 pole · 010103 1 gmu 0.5 t 811 118 620 gmu 1 t 811 123 620 gmu 2 t 811 128 620 gmu 3 t 811 132 620 gmu 4 t 811 134 620 gmu 10 t 811 146

600

S01015 010103

6101620

253240

A466 822A 466 01 A466 822A 466 01

DDI1+N...C0.01 DDI1+N...C0.03 DDI1+N...C0.310 mA 30 mA 300 mA

863 538 311 863 538 321 863 538 341863 546 311 863 546 321 863 546 341863 552 311 863 552 321 863 552 341

863 556 321 863 556 341

863 558 321 863 558 341863 562 321 863 562 341863 566 321 863 566 341

DDIB...C0.01 DDIB...C0.03 DDIB...C0.310 mA 30 mA 300 mA

863 238 311 863 238 321 863 238 341863 246 311 863 246 321 863 246 341863 252 311 863 252 321 863 252 341

863 256 321 863 256 341

863 258 321 863 258 341863 262 321 863 262 341863 266 321 863 266 341

Approvals: Contact Entrelec Approvals: Contact Entrelec

Circuit breakersEarth leakage deviceThermal-magneticAlternating currentSeries DDI

DIN 3

Accessories

Other characteristics

Interrupting capacity

Characteristics

DDI1+N...C...1 pole + neutral in 2 modules

DDIB...C...2 poles protected in 3 modules

Spacing 35 mm (1.38’’)

Life, number of cycles (On+Off)Dielectric withstanding voltage

Tripping curves SDegree of protectionWeightMechanical shock

Ambient temperature

Rated voltage V

Rated wire size AWG / mm²

Part number Part number

Adaptor for DIN 1 rail mount

Type Part number

Type RatingComplete theproduct type

designation byreplacing ..... withthe desired current

rating.For example :

DDI1+N 6 C 0.03DDI1+N 10 C 0.01

DDIB 25 C 0.3

Other ratingsavailable,

consult us.

Standard blocks. Products with other options are available.Consult us.

Standard blocks. Products with other options are available.Consult us.

Note: (1) See page 604 for larger scale curves.

According to standard I.E.C. 1 009 - 1

4 0002 000 V rms

5 In < S < 10 InIP 20

.49 lb (220 gr.)30 g.

-5° C to 40° C

240 V AC, 50/60 Hz

screw clamp for 3 AWG (25 mm²)

240 V AC, 50/60 Hz

screw clamp for 3 AWG (25 mm²)

Spacing 52,5 mm (2.07)

4 0002 000 V rms

5 In < S < 10 InIP 20

.72 lb (325 gr.)30 g.

-5° C to 40° C

Type Part number

Curve :Type :

Sensitivity :Rated current

in Amps

6 000 Amps (10 000 Amps on request)

Curve C (1)

Curve C (1) Curve C (1) Curve C (1) Curve C (1) Curve C (1) Curve C (1)

Multiples of In (rating)

Tim

e in

sec

ond

s

6 000 Amps

Page 12: Circuit breakers GMU GMB Thermal-magnetic 1 pole · 010103 1 gmu 0.5 t 811 118 620 gmu 1 t 811 123 620 gmu 2 t 811 128 620 gmu 3 t 811 132 620 gmu 4 t 811 134 620 gmu 10 t 811 146

601

S01013 010103

ADAPTATEUR A466

DDI3+N...C0.01 DDI3+N...C0.03 DDI3+N...C0.310 mA 30 mA 300 mA

863 638 311 863 638 321 863 638 341863 646 311 863 646 321 863 646 341863 652 311 863 652 321 863 652 341863 656 311 863 656 321 863 656 341

863 658 311 863 658 321 863 658 341863 662 311 863 662 321 863 662 341863 666 311 863 666 321 863 666 341

Approvals: Contact Entrelec

Current correctionfactor vs. temperature

Ambient Correctiontemperature factor°C °F (multiply by)

- 20 - 4 1.25- 10 + 14 1.20- 5 + 23 1.17- 0 + 32 1.15+ 10 + 50 1.10+ 20 + 68 1.05+ 30 + 86 1.00+ 40 + 104 0.95+ 50 + 122 special P/N+ 60 + 140 special P/N+ 70 + 158 special P/N

Internal resistancevs. current rating

Current Internalrating resistance

(A) (mΩ)

DDI3+N3 poles protected + neutral in 4

Spacing 52,8 mm (2.08’’)

Standard blocks. Products with other options are available,example : auxiliary contact. Consult us.

Curve C

See page 604 for larger scale curves.

Part numberCurve C

Multiples of In (rating)

Tim

e in

sec

ond

s

0.5 4 0001 1 2002 4204 16010 1320 6

Table 2

Table 1

A466 822A 466 01

415 V AC, 50 - 60 Hz

screw clamp for 3 AWG (25 mm²)

Type Part number

4 0002 000 V rms

5 In < S < 10 InIP 20

.58 lb (261 gr.)30 g.

-5° C to 40° C

6 000 Amps

Page 13: Circuit breakers GMU GMB Thermal-magnetic 1 pole · 010103 1 gmu 0.5 t 811 118 620 gmu 1 t 811 123 620 gmu 2 t 811 128 620 gmu 3 t 811 132 620 gmu 4 t 811 134 620 gmu 10 t 811 146

602

S01014 010103

2540

A466 822A 466 01 A466 822A 466 01

IDIQ.....N 0.03 IDIQ.....N 0.330 mA 300 mA

861 458 721 861 458 741861 466 721 861 466 741

IDIB... N 0.03 IDIB... N 0.330 mA 300 mA

861 258 721 861 258 741861 266 721 861 266 741

Approvals: Contact Entrelec Approvals: Contact Entrelec

SwitchesEarth leakage deviceAlternating currentSeries IDI

DIN 3

Accessories

Other characteristics

Sensitivity

Characteristics

IDIB...N...2 poles

IDIQ...N...4 poles

Spacing 35 mm (1.38’’)

Life, number of cycles (On+Off)Dielectric withstanding voltage

Degree of protectionWeightMechanical shock

Ambient temperature

Rated voltage V

Rated wire size AWG / mm²

Part number Part number

Adaptor for DIN 1 rail mount

Type Part number

Type RatingComplete theproduct type

designation byreplacing ..... withthe desired current

rating.For example :

IDIB 25 N 0.03IDIQ 40 N 0.3

Other ratingsavailable,

consult us.

Standard blocks. Products with other options are available.Consult us.

Standard blocks. Products with other options are available.Consult us.

According to standard I.E.C. 1 008-1

4 0002 000 V rms

IP 20.42 lb (190 gr.)

30 g.

-5° C to 40° C

240 V AC, 50/60 Hz

screw clamp for 3 AWG (25 mm²)

415 V AC, 50/60 Hz

screw clamp for 3 AWG (25 mm²)

Spacing 70 mm (2.76’’)

4 0002 000 V rms

IP 20.75 lb (340 gr.)

30 g.

-5° C to 40° C

Type Part number

PolesN° 1 N° 2 N° 3 N° 4

Type :Sensitivity :

Rated currentin Amps

Standard : 30 mAmps (10 mAmps, 300 mAmps) Standard : 30 mAmps (10 mAmps, 300 mAmps)

Page 14: Circuit breakers GMU GMB Thermal-magnetic 1 pole · 010103 1 gmu 0.5 t 811 118 620 gmu 1 t 811 123 620 gmu 2 t 811 128 620 gmu 3 t 811 132 620 gmu 4 t 811 134 620 gmu 10 t 811 146

603

S01017 010103

00 01 02 03 33 43 07 08 09

00 01 02 03 04 05 06 07 08 09*

*

Notes: (2) See curves on pages 595 and 605.(1) See curves on pages 591 and 604.

Circuit breakers Series GALAXIE : GD - GH - GN - GV – To order, see page 608

Accessories

Other characteristics

Interrupting capacity

Characteristics SERIES GD SERIES GH SERIES GN SERIES GV

Life, number of cycles (On+Off)Dielectric withstanding voltage

Tripping curves (1) (2) S

Mechanical shock

Ambient temperature

Rated voltage1 + neutral version

One pole version Multipole version

One pole and two pole version

BasesAuxiliary for position signalling (O/F)

Type Part Number

Terminations

According to standard IEC 898

According to standard NF F62 001

4 000 4 000 4 000 4 0002 000 V rms 2 000 V rms 2 000 V rms 2 000 V rms

Curve B : 3 In < S < 5 In - Curve C : 5 In < S < 10 In - Curve D : 10 In < S < 20 In Nominal current 0.1 to 2 A : 5 In < S < 10 In - 3 to 32 A : 7 In < S < 14 In

30 g. 30 g. 30 g. 30 g.

-5° C to 40° C -5° C to 40° C -25° C to + 70° C -25° C to + 70° C

240 V AC (50/60 Hz)240/415 V AC (50/60 Hz) 240/415 V AC (50/60 Hz)

415 V AC (50/60 Hz) 415 V AC (50/60 Hz)48 V DC max. 100 V DC max. 150 V DC max.

P R O J E C T I O N M O U N T I N G S C R E W F L U S H M O U N T I N G Maximum thickness of mounting panel :3 mm. 3 mm. 3 mm. 6 mm. 6 mm. 6 mm. 6 mm.

Dimensions in millimeters

Fastenings and operations (3 poles max. except 02 : 2 poles and 05 : 4 poles)

Fastenings and operations No 00 - 01 - 02 - 03 - 04 - 06 - 07 - 08

Pole Pole Pole Pole Pole Pole Pole Pole PoleN° 2 N° 1 N° 3 N° 2 N° 1 N° 4 N° 3 N° 2 N° 1

1 Width 2 Widths 3 Widths = 1 handle 4 Widths = 2 handles

UL, CSA : For list of certified products : consult us Circuit breakers NF F62 001 : consult us

Four-pole circuit breaker :

Fastening and operation No 05only

Tightening torque :1,8 Nm max. 1,8 Nm max. 1,8 Nm max. 3 Nm max.

16 A max. 240 A max. 16 A max. 16 A max. 16 A max. Except Fastening 08 2 poles max. 2 poles max. 2 poles max.

Type Part Number Type Part Number Type Part Number

NOTE :Neutral on pole N° 1

anyFastenings and operations

3 000 A 4 500 A (models U and D: rating ≥ 5 A)

4 500 A (model L: rating ≥ 10 A)

1 000 A (48 V DC max.) 500 A 1 000 A (48 V DC max.)10 In cal. < 5 A ; 20 In cal > 5 A 10 In cal. < 5 A ; 20 In cal > 5 A 10 In cal. < 5 A ; 20 In cal > 5 A

Fastenings / Operations 00 01 02 03 04 05 06 07 08 09

Size A 8 8 8 8 8 17,5 15 15 21 28

Size C 32 32 32 32 32 37 32 32 32 32

Terminations 00 01 02 03 33 43 07 08 09

Size B 15 4 4 12 4 4 4 4 11

See Accessories, page 607See Options, page 607

See Accessories, page 607See Options, page 607

See Accessories, page 607See Options, page 607

See Accessories, page 607See Options, page 607

Fastenings and operations No 05 - 09

Pole Pole Pole Pole PoleN° 1 N° 2 N° 1 N° 2 N° 3

1 Width 2 Widths 3 Widths

Page 15: Circuit breakers GMU GMB Thermal-magnetic 1 pole · 010103 1 gmu 0.5 t 811 118 620 gmu 1 t 811 123 620 gmu 2 t 811 128 620 gmu 3 t 811 132 620 gmu 4 t 811 134 620 gmu 10 t 811 146

604

S01020 010103

CURVE B CURVE C

CURVE D

THERMAL MAGNETIC AC CURRENT CURVESFOR SERIES GM, GD, GZ, GH, DDI

ALTERNATING CURRENT, at 30° Caccording to NF C 61410 standard

Multiples of In (rating) Multiples of In (rating)

Multiples of In (rating)

Tim

e in

sec

ond

s

Tim

e in

sec

ond

s

Tim

e in

sec

ond

s

Limits standard

For information

Test conditions: - cold (I = 0 before overload)

- overload on all the poles

for multipole devices

Page 16: Circuit breakers GMU GMB Thermal-magnetic 1 pole · 010103 1 gmu 0.5 t 811 118 620 gmu 1 t 811 123 620 gmu 2 t 811 128 620 gmu 3 t 811 132 620 gmu 4 t 811 134 620 gmu 10 t 811 146

605

S01021 010103

5000

2000

1000

500

200

100

50

20

10

5

2

1

0.5

0.2

0.10.05

0.02

0.010.005

0.002

0.0011 1.5 2 3 4 5 10 15 20 30

CURVE B CURVE C

CURVE T

THERMAL MAGNETIC DC CURRENT CURVESFOR SERIES GF, GC, GN AND GV TYPE S

DIRECT CURRENT, at 30° Caccording to NF C 61410 standard

Multiples of In (rating) Multiples of In (rating)

Multiples of In (rating)

Tim

e in

sec

ond

s

Tim

e in

sec

ond

s

Tim

e in

sec

ond

s

THERMAL DC OR AC CURRENT CURVESFOR SERIES GM, GD, GF, GC, GN AND GV TYPE T

ALTERNATING OR DIRECT CURRENT

Page 17: Circuit breakers GMU GMB Thermal-magnetic 1 pole · 010103 1 gmu 0.5 t 811 118 620 gmu 1 t 811 123 620 gmu 2 t 811 128 620 gmu 3 t 811 132 620 gmu 4 t 811 134 620 gmu 10 t 811 146

606

S01022 010103

X H S

S H

X

1

N

111412

N 12 14

N2

1

11

P/N: 822A 466.01

Series GM - GF - GC

OPTIONS AND ACCESSORIES FOR MODULAR CIRCUIT BREAKERS SERIES GM - GF - GC - GZAll circuit breakers are available with one or several poles (multipole)

Auxiliary contacts

Characteristics

Switching capacity (resistive circuit) :

3 A with 240 V AC- max. value : 3 A with 48 V DC

- min. value : 5 mA with 15 V DC

Quick-connect tabs 2,8 x 0,8 mm (S.H.X. terminals)

Series GZ (1+N only)

GM, GF, GC can be ordered equipped with a pushbutton Adapter for mounting on DIN 1 / DIN 3 rails

Page 18: Circuit breakers GMU GMB Thermal-magnetic 1 pole · 010103 1 gmu 0.5 t 811 118 620 gmu 1 t 811 123 620 gmu 2 t 811 128 620 gmu 3 t 811 132 620 gmu 4 t 811 134 620 gmu 10 t 811 146

607

S01023 010103

11

20

20

17.6

==

56

BASE MOUNTINGWithout auxiliary contact

ACCESSORIES FOR CIRCUIT BREAKERS SERIES GD - GN - GV

DIN RAIL MOUNTINGWithout auxiliary contact

With auxiliary contact With auxiliary contact

1 pole 2 poles 3 poles 4 poles

Part number 821B11001 821B21001 821B31001 821B41001

OPTIONS

Base for PCB Cover + waterproof equipment

Auxiliary contact Adjustable thermal protection

Part number : Part number : Part number :

821E20801 821E20601 821E10001

1 pole 2 poles 3 poles 4 poles

without contact 821B13001 821B23001 821B33001 821B43001

with contact 1 821B13101 821B23101 821B33101 821B43101

with contact 2 821B23201 821B33201 821B43201

with contact 3 821B33301 821B43301

with contact 4 821B43401

1 pole 2 poles 3 poles 4 poles

without contact 821B10001 821B20001 821B30001 821B40001

with contact 1 821B10101 821B20101 821B30101 821B40101

with contact 2 821B20201 821B30201 821B40201

with contact 3 821B30301 821B40301

with contact 4 821B40401

Page 19: Circuit breakers GMU GMB Thermal-magnetic 1 pole · 010103 1 gmu 0.5 t 811 118 620 gmu 1 t 811 123 620 gmu 2 t 811 128 620 gmu 3 t 811 132 620 gmu 4 t 811 134 620 gmu 10 t 811 146

608

S01016 010103

GD B 10 U 07 03 P2 - T - - - -

HOW TO ORDER GD - GH - GN - GV SERIES CIRCUIT BREAKERS

SERIES

GD Standard Galaxie AC 240/415 V 50/60 Hzcan be used at 48 V DC max.

GH High rupturing capacity GalaxieAC 240/415 V 50/60 Hz

GN Special Galaxie 100 V DC max.

GV Special Galaxie 150 V DC max.

GA Severe environment Galaxie(i.e. military use) consult us

VERSIONS

U One-pole (1 protected pole)

B Two-pole (2 protected poles)

T Three-pole (3 protected poles)

Q Four-pole (4 protected poles)

1+N Two-pole (1 protected pole + neutral)

3+N Four-pole (3 protected poles + neutral)

RATING (In : Amps)

0.1 - 0.2 - 0.3 - 0.5 - 1 - 1.5 - 2 - 2.5 - 3 - 4 - 56 - 8 - 10 - 12 - 13 - 16 - 20 - 25 - 30 - 32Heavy duty types : ratings according to NF EN60 898Other ratings, consult us.

MODELS

L Thermal-magnetic - Curve Baccording to NF EN60 898

U Thermal-magnetic - Curve Caccording to NF EN60 898

D Thermal-magnetic - Curve Daccording to NF EN60 898Ratings 6 to 32 A

S Thermal-magnetic (series GN and GV only)according to NF F 62001

T Thermal (except series GH)

FASTENINGS AND OPERATIONS* *

00 - 01 - 02 - 03 - 04 - 05 - 06 - 07 - 08 - 09

TERMINATIONS* *

00 - 01 - 02 - 03 - 07 - 08 - 09 - 33 - 43

RATING ENGRAVED

J On resetting button

METAL THREADED BUSHING

W For fastening and operations 6-7-8.Tightening torque : 3 Nm max.(compulsory with option K)

CIRCUIT BREAKER SERIES GD MODEL D*

R With adjustable thermal protection(Not possible with option K)

MECHANICAL IMPACT

V 50 g

E 100 G

TROPICALIZATION

T (Compulsory with option E 100)

THERMAL PROTECTION

C Temperature compensated from + 20°C to + 60°C

K Temperature compensated from - 40°C to + 85°Cseries GD, GH and GA (Compulsory with Option W)

AUXILIARY CONTACT FOR POSITION SIGNALLING O/F***

P1 on 1 pole

P2 on 2 poles

P3 on 3 poles

P4 on 4 poles

* Series GD, Model D only

** See page 603

*** See Accessories, page 607

EXAMPLE :

1 Circuit breaker Series : Galaxie standard AC - Version : 2 protected poles - Rating : 10 A - Model : magnetic-thermal, curve C - Fastenings and operations :Threaded bushing flush type 2 buttons - Terminations : Screws and back connectors - With Options Auxiliary for position signalling O/F : on 2 poles - Tropicalizationhas reference GDB10U0703 P2T

OPTIONSCIRCUIT BREAKERS

FITTED OR UNPLUGGABLE OR PROJECTING CIRCUIT BREAKERS