(Annexure-V) CENTRAL INSTITUTE OF FISHERIES EDUCATION (Deemed University) I.C.A.R. VERSOVA, MUMBAI-400 061. ANNUEXURE TO SCHEDULE TO TENDER (to be returned by Bidders along with the Tender duly completed and Signed) Name of Equipment: Kjel.Tec for N Estimation. Qty: 1 No. Item No:- 01 (01) Specification Kjel Tec:- 2400/2600. Standard 10 programme. Power consumption 2200w. Water Consumption during distillation 1 liter/min at 5 0 C. Auto Sampler System. Titration, Standard Service Software, Printer, Balance, Computer interflow. 800 Storage of 2aw data. Standard false replacement sensor. Removable safety door. Removable drip tray, reagent alarm. Automatic alkali addition. Distillation <3min 30 sec. Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI.

cife.edu.incife.edu.in/cifehindi/docs/sep2010/All_Equipment... · Web viewBids must have supporting documents (technical) literature of copies of relevant pages from the service manual

Embed Size (px)

Citation preview

(Annexure-V)CENTRAL INSTITUTE OF FISHERIES EDUCATION

(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: Kjel.Tec for N Estimation. Qty: 1 No.

Item No:- 01 (01)

Specification

Kjel Tec:- 2400/2600.

Standard 10 programme.

Power consumption 2200w.

Water Consumption during distillation 1 liter/min at 50C.

Auto Sampler System.

Titration, Standard Service

Software, Printer, Balance, Computer interflow.

800 Storage of 2aw data.

Standard false replacement sensor.

Removable safety door.

Removable drip tray, reagent alarm.

Automatic alkali addition.

Distillation <3min 30 sec.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI.

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and signed)

Technical Compliance Statement.Name of Equipment: Kjel.Tec for N Estimation. Qty: 1 No. Item No:- 01 (01)

Specification asked for Specification Offered.

Kjel Tec:- 2400/2600.

Standard 10 programme.

Power consumption 2200w.

Water Consumption during distillation 1 liter/min at 50C.

Auto Sampler System.

Titration, Standard Service.

Software, Printer, Balance, Computer interflow.

800 Storage of 2aw data.

Standard false replacement sensor.

Removable safety door.

Removable drip tray, reagent alarm.

Automatic alkali addition.

Distillation <3min 30 sec.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.Note: - Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-1. Compliance/Deviation statement comparing the specification of the quoted model to the

required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS (Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: UV-Visible Double Beam Spectrophotometer. Qty: 1 No.

Item No:- 02 (02)

Specification

Double beam with variable slit width of 0.5nm.

Wave length range 190.0 to 1100 nm.

Automatic self check system.

Control by 32 bit UV-Vis software.

Measurement of transmittance, absorbance or conc., via factor, simple standard or line

calibration.

Spectra measurement.

Kinetic measurement.

Printing of storage of method of measurement results.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI.

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and signed)

Technical Compliance Statement.

Name of Equipment: UV-Visible Double Beam Spectrophotometer. Qty: 1 No. Item No:- 02 (02)

Specification asked for Specification Offered.

Double beam with variable slit width of 0.5nm.

Wave length range 190.0 to 1100 nm.

Automatic self check system.

Control by 32 bit UV-Vis software.

Measurement of transmittance, absorbance or conc., via

factor, simple standard or line calibration.

Spectra measurement.

Kinetic measurement.

Printing of storage of method of measurement results.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.Note: - Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-1. Compliance/Deviation statement comparing the specification of the quoted model to the

required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS

(Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: Nephalometer. Qty- 1 No. Item No:- 03 (20)

Specification

Principal of Operation- Nephalometer.

Range NTU :- 0-2000

Nephalometer :- 0-4000

EPA :- 0-4000 NTU

Accuracy :- ± 2% of reading + 0.01 NTU.

Resolution :- 0.01 NTU (0-9.99)

Response Time :- < 8 Seconds.

Calibration :- 1,10,100,1000 NTU.

Sample Cell Size :- 24 mm

Sample Size :- 412 ml.

Display :- Custom LTD, RTC – yes.

Light Source :- White, IR, Operating Time :- 400 to 1400F

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI.

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.Name of Equipment: Nephalometer.. Qty- 1 Nos.

Item No:- 03 (20)

Specification asked for Specification Offered.

Principal of Operation- Nephalometer.

Range NTU :- 0-2000

Nephalometer :- 0-4000

EPA :- 0-4000 NTU

Accuracy :- ± 2% of reading + 0.01 NTU.

Resolution :- 0.01 NTU (0-9.99)

Response Time :- < 8 Seconds.

Calibration :- 1,10,100,1000 NTU.

Sample Cell Size :- 24 mm

Sample Size :- 412 ml.

Display :- Custom LTD, RTC – yes.

Light Source :- White, IR, Operating Time :- 400 to 1400F

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-1. Compliance/Deviation statement comparing the specification of the quoted model

to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS. (Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION

(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: Student Microscope Qty :- 10 Nos.

Item No:- 04 (09)

Specification

450C Binocular tube WF 10 x /18 mm eyepiece.

Achromatic Objective:-

4x,10x, 40x, 100x oil condenser NA 1.25 with Iris Diaphragm.

Coaxial coarse and fine focusing system with division 0.001 mm and maximum

20 mm.

Stage 130/130 mm, moving range 50mm x 78mm with vernier scale locking

system at left side.

6V/20 watt halogen lamp with day light filter.

Optional: - Universal phase contract and dark field attachment.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.Name of Equipment: Student Microscope. Qty:-10 Nos.

Item No:- 04 (09)

Specification asked for Specification Offered.

450C Binocular tube WF 10 x /18 mm eyepiece.

Achromatic Objective:-

4x,10x, 40x, 100x oil condenser NA 1.25 with Iris Diaphragm.

Coaxial coarse and fine focusing system with division 0.001 mm and

maximum 20mm.

Stage 130/130 mm, moving range 50mm x 78mm with vernier scale

locking system at left side.

6V/20 watt halogen lamp with day light filter.

Optional :- Universal phase contract and dark field attachment.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-1. Compliance/Deviation statement comparing the specification of the quoted model

to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS.

(Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: Spectral Confocal Laser Scanning Microscope. Qty :- 1 Nos.

Item No:- 05 (53)

Specification

1. Inverted Fully Motorized and Automated Microscope:-a). Fully motorized PC controlled inverted microscope.b). Completely automated DIC (DIC prisms selection, Motorized Polarizer and Analyzer).c). Confocal grade objectives- 10x, 20x, 40x/1.25 oil (NA) and 60/63x/1.4 (NA) Oil imm.d). Z step size minimum 15nm.e). Motorized fluorescence turret for 6 fluorescence filter cubes, Mercury Arc Lamp with a life of minimum 2000 Hrs. Standard Filter cubes for DAPI, FITC and Rhodamine.f). System should have laser based focus drift management or a built in stability Manager alongwith Universal sample holder and imported antivibration table.2. Confocal Laser Scanning System:- A Confocal point scanner and detection system, with individual laser ports for UV, VIS and IR which is free from optical filters and secondary dichroics for highest system flexibility.

Spectral Detection:- Minimum 2 independent built into the scanner spectral PMT detectors tunable from 400-800 nm. Additional Transmitted light detector should also be quoted. Cooled PMT’s/GaSP Detectors and the systems should be upgradable to additional two spectral PMT detectors.

Laser & AOTF for Excitation:- Argon minimum 65m W-458/476/488/514 nm, HeNe-543 nm and HeNe-633nm, Acousto Optical Tunable Filter for simultaneous control of laser lines.

High Resolution Scanning :- Atleast Scan Resolution 7k x 7k with scanning area greater than or equal to 21mm, with minimum 5 frames per second at 512 x 512 resolution, with Scan zoom 1:50x and scan rotation minimum 180 Deg. 3. Software :- Basic operation software like multi-dimensional imaging, region of interest (ROI) scan, excitation line/frame sequential scan emission, spectrum recording quantification tools, multi-color restoration, spectral un-mixing, general time lapse experiment control.

Application Software: - Software should be controlling motorized functions of microscope, scan head control, laser control including AOTF, Image acquisition and processing.a). Should be capable of saving all parameters with the image for reproducible imaging.b). Line, Curved line, Frame, Z Stack, Time series & Multicolour imaging capabilities.c). Dedicated FRET SE, FRET AB & FRAP software’s.d). Standard Geometry Measurements like length, area, angles etc, including intensity.e). 3D image reconstruction from a Z-Stack image series and Advanced 3D movie making.f). Spectral unmixing and emission finger printing with separation of overlapping emission Spectra of fluorophores.g) Training at the manufacturers application centre should be included.Windows 7, Workstation with single 30” monitor.Optional Item:- Please quote 405nm Laser with necessary optics.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.Name of Equipment: Spectral Confocal Laser Scanning Microscope. Qty:-1Nos.

Item No:- 05 (53)

Specification asked for Specification Offered.

1. Inverted Fully Motorized and Automated Microscope:-a). Fully motorized PC controlled inverted microscope.b). Completely automated DIC (DIC prisms selection, Motorized Polarizer and Analyzer).c). Confocal grade objectives- 10x, 20x, 40x/1.25 oil (NA) and 60/63x/1.4 (NA) Oil imm.d). Z step size minimum 15nm.e). Motorized fluorescence turret for 6 fluorescence filter cubes, Mercury Arc Lamp with a life of minimum 2000 Hrs. Standard Filter cubes for DAPI, FITC and Rhodamine.f). System should have laser based focus drift management or a built in stability Manager alongwith Universal sample holder and imported antivibration table.2. Confocal Laser Scanning System:- A Confocal point scanner and detection system, with individual laser ports for UV, VIS and IR which is free from optical filters and secondary dichroics for highest system flexibility.

Spectral Detection:- Minimum 2 independent built into the scanner spectral PMT detectors tunable from 400-800 nm. Additional Transmitted light detector should also be quoted. Cooled PMT’s/GaSP Detectors and the systems should be upgradable to additional two spectral PMT detectors.

Laser & AOTF for Excitation:- Argon minimum 65m W-458/476/488/514 nm, HeNe-543 nm and HeNe-633nm, Acousto Optical Tunable Filter for simultaneous control of laser lines.

High Resolution Scanning :- Atleast Scan Resolution 7k x 7k with scanning area greater than or equal to 21mm, with minimum 5 frames per second at 512 x 512 resolution, with Scan zoom 1:50x and scan rotation minimum 180 Deg.3. Software :- Basic operation software like multi-dimensional imaging, region of interest (ROI) scan, excitation line/frame sequential scan emission, spectrum recording quantification tools, multi-color restoration, spectral un-mixing, general time lapse experiment control.

Application Software: - Software should be controlling motorized functions of microscope, scan head control, laser control including AOTF, Image acquisition and processing.a). Should be capable of saving all parameters with the image for reproducible imaging.b). Line, Curved line, Frame, Z Stack, Time series & Multicolour imaging capabilities.c). Dedicated FRET SE, FRET AB & FRAP software’s.

d). Standard Geometry Measurements like length, area, angles etc, including intensity.e). 3D image reconstruction from a Z-Stack image series and Advanced 3D movie making.f). Spectral unmixing and emission finger printing with separation of overlapping emission spectra of fluorophores.g) Training at the manufacturers application centre should be included.Windows 7, Workstation with single 30” monitors.Optional Item:- Please quote 405nm Laser with necessary optics.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-1. Compliance/Deviation statement comparing the specification of the quoted model

to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS.

(Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: Flow-Through Dissolved Oxygen Analyser. Qty :- 1 Nos.

Item No:- 06 (57)

Specification

Channels Two

Sensor Optical

Ambient Temperature Up to 550C

Display LCD Graphic

Sensor Check Automatic Self diagnostics

Sensor to Analyser distance 600 m or more

Accuracy 1% of reading or 0.02 ppm,

whichever is greater

Sensitivity 0.01 ppm

Repeatability 0.01 ppm

Measuring ranges 0-25 ppm

Temperature Compensation 0-600C

Memory Backup Should be present

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.Name of Equipment: Flow-Through Dissolved Oxygen Analyser. Qty:-1Nos.

Item No:- 06 (57)

Specification asked for Specification Offered.

Channels Two

Sensor Optical

Ambient Temperature Up to 550C

Display LCD Graphic

Sensor Check Automatic Self diagnostics

Sensor to Analyser distance 600 m or more

Accuracy 1% of reading or 0.02 ppm, whichever is greater

Sensitivity 0.01 ppm

Repeatability 0.01 ppm

Measuring ranges 0-25 ppm

Temperature Compensation 0-600C

Memory Backup Should be present

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-1. Compliance/Deviation statement comparing the specification of the quoted model

to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS. (Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: Plant Growth Chamber Qty :- 1 Nos.

Item No:- 07 (65)

Specification

Capacity 400 l or more

Temperature Range 0 to 600C

Accuracy ± 0.10C

Uniformity ± 0.5-1.00C at 20.00C

Humidity Range 30 to 98%

Accuracy ± 1%

Uniformity ± 2-3% at 60%

Sensor Electronic

Humidifier Evaporation by fan with heater

Controller Microprocessor based, Programmable

Display LCD Back Light

Illumination Range 0 to 20,000 Lux

Lamp FL 40 W x 15 EA, with Lamp on Delay

Material Inner Stainless Steel

Outer Powder Coated Steel

Door Inner Tempered Safety Glass with Silicon Packing

Outer 3 Side Magnetic Packing Door

Safety Over Temperature Cut-Off, Over Current

Breaker, Self Diagnostics.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.

Name of Equipment: Plant Growth Chamber. Qty:-1Nos.

Item No:- 07 (65)

Specification asked for Specification Offered.

Capacity 400 l or more

Temperature Range 0 to 600C

Accuracy ± 0.10C

Uniformity ± 0.5-1.00C at 20.00C

Humidity Range 30 to 98%

Accuracy ± 1%

Uniformity ± 2-3% at 60%

Sensor Electronic

Humidifier Evaporation by fan with heater

Controller Microprocessor based,

Programmable

Display LCD Back Light

Illumination Range 0 to 20,000 Lux

Lamp FL 40 W x 15 EA, with Lamp on

Delay

Material Inner Stainless Steel

Outer Powder Coated Steel

Door Inner Tempered Safety Glass with

Silicon Packing

Outer 3 Side Magnetic Packing Door

Safety Over Temperature Cut-Off,

Over Current Breaker, Self

Diagnostics.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.

Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-

1. Compliance/Deviation statement comparing the specification of the quoted model to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS.

(Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: Preparative Table Top Ultra Centrifuge Qty :- 1 Nos.

Item No:- 08 (75)

Specification

Maximum Speed 150,000 rpm

Maximum Force 1,019,000 x g

Speed Control ± 50 rpm of set speed

Sample imbalance tolerance ± 5 ml or 10% whichever is greater.

Drive Cooling Air cooled

Refrigeration System Solid state; no CFCs, ODCs

Set Temperature range 0 to 400C in 100C increments

Temperature Control ± 20C of set temperature.

Acceleration/Deceleration rates 10/11

Rotor Safety Should be built in

Remote Control Should be provided

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.Name of Equipment: Preparative Table Top Ultra Centrifuge. Qty:-1Nos.

Item No:- 08 (75)

Specification asked for Specification Offered.

Maximum Speed 150,000 rpm

Maximum Force 1,019,000 x g

Speed Control ± 50 rpm of set speed

Sample imbalance tolerance ± 5 ml or 10% whichever is

greater.

Drive Cooling Air cooled

Refrigeration System Solid state; no CFCs, ODCs

Set Temperature range 0 to 400C in 100C increments

Temperature Control ± 20C of set temperature.

Acceleration/Deceleration rates 10/11

Rotor Safety Should be built in

Remote Control Should be provided

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-1. Compliance/Deviation statement comparing the specification of the quoted model

to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS. (Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION

(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: Continuous Flow Centrifuge Qty :- 1 Nos.

Item No:- 09 (76)

Specification

G-Force 17,000 or more

Speed Variable

Bowl Capacity 2.0 l or more

Process Volume 20-50 l

Cooling System/Coil To be Provided

Tachometer Electric

Safety Explosion Proof

Bowls Clarifying, Separating, Emulsifying,

Adjustable Separating and Closed.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.Name of Equipment: Continuous Flow Centrifuge. Qty:-1Nos.

Item No:- 09 (76)

Specification asked for Specification Offered.

G-Force 17,000 or more

Speed Variable

Bowl Capacity 2.0 l or more

Process Volume 20-50 l

Cooling System/Coil To be Provided

Tachometer Electric

Safety Explosion Proof

Bowls Clarifying, Separating, Emulsifying,

Adjustable Separating and Closed.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-1. Compliance/Deviation statement comparing the specification of the quoted model

to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS.

(Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: Horizontal Gel Electrophoresis Apparatus (Electrophoresis Apparatuses).

Item No:- 10 (87)

Specification

1. Horizontal Agarose gel electrophoresis apparatus 1 Nos.a. Buffer tank with lid, connectors and electrodes for unidirectional migration; b. A pair of connecting cords;c. UV-transparent gel tray about 15 x 20 cm with a pair of appropriate combs (1.5 mm thick);d. Provision for fitting 2 combs on one gel.2. Power pack for (western blotting) Electrophoresis 1 Nos.a. Dual mode (CV & CC) with auto-crossover; range upto 200 V, 500 mA, continuously variable

over range. b. Two outputs in parallel; c. Independent digital displays for mA and volts (resolution 1 mA, 1 V); protection of outputs

against short-circuiting; d. Over voltage tripping circuit to limit electronic component damage. e. Input V: 2203. Power pack for (Comet assay) Electrophoresis 1 Nos.a. Dual mode (CV & CC) with auto-crossover; range upto 30 V, 400 mA, continuously variable

over range. b. Single output; c. Independent digital displays for mA and volts (resolution 1 mA, 1 V); protection of outputs

against short-circuiting; d. Over voltage tripping circuit to limit electronic component damage. e. Input V: 220 4. Horizontal Electrophoresis system (Comet assay) 1 Nos.a. Apparatus should accommodate six 3x1” glass slides for comet assay.b. Complete ready to use unit with lid; buffer tank, male connectors and electrodes (for uni

directional migration); c. A pair of connecting cords. Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI.

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.

Name of Equipment: Horizontal Gel Electrophoresis Apparatus (Electrophoresis Apparatuses).

Item No:- 10 (87)

Specification asked for Specification Offered.

1. Horizontal Agarose gel electrophoresis apparatus 1 Nos.a. Buffer tank with lid, connectors and electrodes for unidirectional migration; b. A pair of connecting cords;c. UV-transparent gel tray about 15 x 20 cm with a pair of appropriate combs (1.5 mm thick);d. Provision for fitting 2 combs on one gel.

2. Power pack for (western blotting) Electrophoresis 1 Nos.a. Dual mode (CV & CC) with auto-crossover; range upto 200 V, 500 mA, continuously variable over range. b. Two outputs in parallel; c. Independent digital displays for mA and volts (resolution 1 mA, 1 V); protection of outputs against short-circuiting; d. Over voltage tripping circuit to limit electronic component damage. e. Input V: 2203. Power pack for (Comet assay) Electrophoresis 1 Nos.a. Dual mode (CV & CC) with auto-crossover; range upto 30 V, 400 mA, continuously variable over range. b. Single output; c. Independent digital displays for mA and volts (resolution 1 mA, 1 V); protection of outputs against short-circuiting; d. Over voltage tripping circuit to limit electronic component damage. e. Input V: 2204. Horizontal Electrophoresis system (Comet assay) 1 Nos.a. Apparatus should accommodate six 3x1” glass slides for comet assay.b. Complete ready to use unit with lid; buffer tank, male connectors and electrodes (for uni directional migration); c. A pair of connecting cords.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.

Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-1. Compliance/Deviation statement comparing the specification of the quoted model

to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS.

(Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: Speed Vacuum Concentrator Qty- 1 No.

Item No:- 11 (95)

Specification

Optimal and rapid vacuum evaporation of DNA, RNA and proteins samples should be possible at low temperature (~40C)

The Concentrator should be a complete system with a solvent / chemical resistant diaphragm

pump and efficient and gentle vacuum concentration ability.

Choice of heating levels; sub-ambient and above.

Sensor to reads internal chamber temperature.

Chemical-resistant chamber.

Centrifugation and Desiccators function.

Gas ballast valve to allow air to flow into the pump chamber to clear the pump of moisture and

prevent condensation/ Automatic condensate drain.

Timer selection between 1 min and 9:59 h.

Brake function.

Purification of the exhaust air against unpleasant vapors.

Rotor Required: Fixed angle rotor for 1.5/2.0 ml tubes.

Adapters should be available for 0.2 ml PCR tubes and 0.5ml microcentrifuge tubes in 1.5ml rotor

for future upgradation.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI.

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.

Name of Equipment: Speed Vacuum Concentrator. Qty- 1 Nos.

Item No:- 11 (95)

Specification asked for Specification Offered.

Optimal and rapid vacuum evaporation of DNA, RNA and proteins samples should be possible at low temperature (~40C)

The Concentrator should be a complete system with a solvent /

chemical resistant diaphragm pump and efficient and gentle

vacuum concentration ability.

Choice of heating levels; sub-ambient and above.

Sensor to reads internal chamber temperature.

Chemical-resistant chamber.

Centrifugation and Desiccators function.

Gas ballast valve to allow air to flow into the pump chamber to clear

the pump of moisture and prevent condensation/ Automatic

condensate drain.

Timer selection between 1 min and 9:59 h.

Brake function.

Purification of the exhaust air against unpleasant vapors.

Rotor Required: Fixed angle rotor for 1.5/2.0 ml tubes.

Adapters should be available for 0.2 ml PCR tubes and 0.5ml micro

centrifuge tubes in 1.5ml rotor for future upgradation.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.

Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-

1. Compliance/Deviation statement comparing the specification of the quoted model to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS.

(Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: Real Time PCR System. Qty- 1 No.

Item No:- 12 (89)

Specification

Application : Absolute and Relative quantitation: Simultaneous analysis of data for relative quantitation, multiplex-PCR, allelic discrimination (SNP), and Dissociation curve analysis as well as pathogen detection. : Both SYBR Green and Taqman probe-based assays.

Hardware : 96 well thermal cycling system: Temperature range of 4oC – 105oC: Provision for both 96 well plates and individual 0.2 ml PCR tubes

Thermal cycling/Reaction volume

: Reaction volume 10-50µl : Universal thermal cycling conditions to eliminate optimization of PCR conditions

Excitation and Filters : Five position fluorescence excitation and emission filters. : Should collect data for all 5 filters for all wells regardless of plate setup.: Provision to alter the plate setup after run completes.

Compatibility : Provision to segregate multiple dyes Using software: Provision to add new dyes without any hardware change.

Software : Dedicated licensed full version software for Taqman primer and probe design

: Dedicated computer for real time PCR operations.Service : Custom designed primer probes for absolute

quantification, gene expression assays and genotyping assays

License : The quote system must have full license for PCR process. : A copy of the license must be attached to the offer.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI.

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.

Name of Equipment: Real Time PCR System. Qty- 1 Nos.

Item No:- 12 (89)

Specification asked for Specification Offered.

Application : Absolute and Relative quantitation: Simultaneous analysis of data for relative

quantitation, multiplex-PCR, allelic discrimination (SNP), and Dissociation curve analysis as well as pathogen detection.

: Both SYBR Green and Taqman probe- based assays.

Hardware : 96 well thermal cycling system: Temperature range of 4oC – 105oC: Provision for both 96 well plates and individual 0.2 ml PCR tubes

Thermal cycling/Reaction volume

: Reaction volume 10-50µl : Universal thermal cycling conditions to eliminate optimization of PCR conditions

Excitation and Filters

: Five position fluorescence excitation and emission filters. : Should collect data for all 5 filters for all wells regardless of plate setup.: Provision to alter the plate setup after run completes.

Compatibility : Provision to segregate multiple dyes Using software: Provision to add new dyes without any hardware change.

Software : Dedicated licensed full version software for Taqman primer and probe design

: Dedicated computer for real time PCR operations.

Service : Custom designed primer probes for absolute quantification, gene expression assays and genotyping assays

License : The quote system must have full license for PCR process. : A copy of the license must be attached to the offer.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.

Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-1. Compliance/Deviation statement comparing the specification of the quoted model

to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS.

(Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: Visible Implant Elastometer. Qty-

Item No:- 13 (90)

Specification

Sr. No Colour Type Quantity

1 Red 15000

2 Orange 15000

3 Yellow 15000

4 Blue 15000

5 Pink 15000

6 Green 15000

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI.

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.

Name of Equipment: Visible Implant Elastometer. Qty-

Item No:- 13 (90)

Specification asked for Specification Offered.

Colour Type Quantity

Red 15000

Orange 15000

Yellow 15000

Blue 15000

Pink 15000

Green 15000

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.

Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-1. Compliance/Deviation statement comparing the specification of the quoted model

to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS.

(Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: Computer Aided Ornamental Fish Colour Analyser. Qty :- 1Nos.

Item No:- 14 (100)

Specification

True color Digital image capture device with appropriate color filters (Deice should be

able to capture the size ranging from 0.5 cm (or less) to 5.0 cm (or more)

Compatible computer hardware & Software with all necessary attachment devices.

The software should be loaded preferable without external hardware key.

Color analysis by (RGB) gray scale (256shade or more on 8 bits or higher version).

Image file format support: JEPG 2000 or higher.

Zeiss LSM

Leica LEI

Image-Pro SEQ

Metamorph SDK

FITS and Others.

Automatically archive and search, provide background archiving facility. Need to have

online upload/download facility. Data viewing enhancements, display data on images.

Image data conversion in spread sheet etc. Simplified user interface. Local user support

on both hardware and software and initial training.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.Name of Equipment: Computer Aided Ornamental Fish Colour Analyser. Qty:- 1 Nos.

Item No:- 14 (100)

Specification asked for Specification Offered.

True color Digital image capture device with appropriate color filters

(Deice should be able to capture the size ranging from 0.5 cm (or

less) to 5.0 cm (or more)

Compatible computer hardware & Software with all necessary

attachment devices.

The software should be loaded preferable without external hardware

key.

Color analysis by (RGB) gray scale (256shade or more on 8 bits or

higher version).

Image file format support: JEPG 2000 or higher.

Zeiss LSM

Leica LEI

Image-Pro SEQ

Metamorph SDK

FITS and Others.

Automatically archive and search, provide background archiving

facility. Need to have online upload/download facility. Data viewing

enhancements, display data on images.

Image data conversion in spread sheet etc. Simplified user interface.

Local user support on both hardware and software and initial training.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.

Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-1. Compliance/Deviation statement comparing the specification of the quoted model

to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS.

(Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: BOD Incubators Qty :- 1 Nos.

Item No:- 15 (92)

Specification

Capacity: - ~6 Cu.Ft.

Volume :- ~160-180 l

Three Shelves.

Temperature range 50C to 600C

Sensitivity :- ± 0.50C

Chamber illumination with white fluorescent and U.V. Lights

Stainless steel inner chamber.

CFC free refrigeration.

Self illuminated mains ON/OFF Switch Indicating Lamps, Electronics.

Digital Temp.Controller- Cum-indicator and fuse.

Safety thermostat to prevent over shoot.

Standard Model-Time proportional ON/OFF controller cum Indicator.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.

Name of Equipment: BOD Incubator. Qty:-1 Nos.

Item No:- 15 (92)

Specification asked for Specification Offered.

Capacity: - ~6 Cu.Ft.

Volume :- ~160-180 l

Three Shelves.

Temperature range 50C to 600C

Sensitivity :- ± 0.50C

Chamber illumination with white fluorescent and U.V. Lights

Stainless steel inner chamber.

CFC free refrigeration.

Self illuminated mains ON/OFF Switch Indicating Lamps,

Electronics.

Digital Temp.Controller- Cum-indicator and fuse.

Safety thermostat to prevent over shoot.

Standard Model-Time proportional ON/OFF controller cum

Indicator.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.

Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-1. Compliance/Deviation statement comparing the specification of the quoted model

to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS.

(Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: High Speed Table Top Microfuge Qty :- 1 Nos.

Item No:- 16 (84)

Specification

Refrigerated with temperature range between 00C and + 400C

Maximum Speed: - 13000-13500 rpm.

Maximum rcf :- ~ 20,000 x g

Acceleration time to maximum speed :- <13s

Breaking time to maximum speed :- <11s

Rotor: - Fixed angle 24 x 1.5/2 ml tubes.

Power supply :- 230 V

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.

Name of Equipment: High Speed Table Top Microfuge. Qty:-1Nos.

Item No:- 16 (84)

Specification asked for Specification Offered.

Refrigerated with temperature range between 00C and +

400C

Maximum Speed: - 13000-13500 rpm.

Maximum rcf :- ~ 20,000 x g

Acceleration time to maximum speed :- <13s

Breaking time to maximum speed :- <11s

Rotor: - Fixed angle 24 x 1.5/2 ml tubes.

Power supply :- 230 V

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-

1. Compliance/Deviation statement comparing the specification of the quoted model to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS.

(Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: Electronic Balance Qty :- 1 Nos.

Item No:- 17 (93)

Specification

Capacity :- 220 g

Readability :- 0.1 g

Operating Temperature (50C – 400C)

Steel Pan Size :- 80mm

User Selectable stability

Large backlit LCD display

Automatic internal calibration

Hanger for below balance weighing

Standard RS232C interface

Units gm,mg,oz etc.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.

Name of Equipment: Electronic Balance. Qty:-1Nos.Item No:- 17 (93)

Specification asked for Specification Offered.

Capacity :- 220 g

Readability :- 0.1 g

Operating Temperature (50C – 400C)

Steel Pan Size :- 80mm

User Selectable stability

Large backlit LCD display

Automatic internal calibration

Hanger for below balance weighing

Standard RS232C interface

Units gm,mg,oz etc.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-

1. Compliance/Deviation statement comparing the specification of the quoted model to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS.

(Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: Cold Chamber Qty :- 1 Nos.

Item No:- 18 (118)

Specification

Walk-in-Chiller room dimension 11’ 7” x 10’ 7’1/2” x 8’ 0-1/4” (Ext. Dime)

Internal Volume 790 cubic ft (approx)

Panel Design PUF panels with Kolpak Design.

Cold Room Assembling 1. Cam Lock arrangement between wall and

ceiling joints.

2. Cam Lock arrangement wall and flooring joints.

3.L-Shaped rounded corner panels.

View Port (14” x 14”) – 5Nos. (one on Door and 4 on wall

panels)

Hardware on Door Kayson make (Imported )

Room temperature required 00C to -50C

Insulation type 100 mm thick PUF panels with0.55 mm thick SS

Inside and SS Outside.

Flooring Floor Panel with Marine ply (9mm) along with

Aluminium cheaquered (2mm) plate.

Incoming Product rate Chemicals for Lab equipment.

Incoming product temperature 300C

Pull down time 24 hours

Door size Clear door opening of 34” x 78” (1 Nos.)

Ambient temperature + 380C

Cooling unit model LST 065-HGM 022

Capacity 8400 btu/hr at 100C SST at 380C Ambient

temperature.

Cooling unit type Air cooled, spilt type

Density of panels 40 ± 2 Kg/cubic meter

Type of compressor Hermetic

Electric Supply 230V/1Ph/50Hz

Compressor run time 16 Hours

Refrigerant R 22

Door Type Heavy duty hinges

Door Frame construction All accessories like light switch, temperature

indicator are fitted on the door frame.

Construction of the door 1. Flush fir with FRP Door perimeter.

2. Door closure and sweep Gasket.

3. The door should contain magnetic gaskets to

rest on stainless steel strip on door frame.

4. The stainless steel strip should contain door

heater to prevent Frost Formation on the door.

5. Digital Temperature indicator, light switch and

wiring connecting the same should be concealed

inside the panels.

Panel Assembly sealing PVC gaskets between adjacent wall panels to

form Tight Joint.

Temperature indicator Digital Temperature indicator.

Compressive strength at 10% 2-6 Kg/Square meter deformation.

Adhesive Strength 2.9 Kg/Square meter.

Dimensional Variation < 2% (48 Hours)

Closed cell content 90-95%

Thermal Conductivity 0.019-0.022 W/m.deg.c

Water absorption 1 w/v

Safety latch at door Swing type

Blowing agent R-141B (Non CFC)

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.Name of Equipment: Cold Chamber. Qty:-1 Nos.

Item No:- 18 (118)

Specification asked for Specification Offered.

Walk-in-Chiller room dimension 11’ 7” x 10’ 7’1/2” x 8’ 0-1/4” (Ext.

Dime)

Internal Volume 790 cubic ft (approx)

Panel Design PUF panels with Kolpak Design.

Cold Room Assembling 1. Cam Lock arrangement between

wall and ceiling joints.

2. Cam Lock arrangement wall and

flooring joints.

3.L-Shaped rounded corner panels.

View Port (14” x 14”) – 5Nos. (one on Door and

4 on wall panels)

Hardware on Door Kayson make (Imported )

Room temperature required 00C to -50C

Insulation type 100 mm thick PUF panels with0.55

mm thick SS Inside and SS Outside.

Flooring Floor Panel with Marine ply (9mm)

along with Aluminium cheaquered

(2mm) plate.

Incoming Product rate Chemicals for Lab equipment.

Incoming product temperature 300C

Pull down time 24 hours

Door size Clear door opening of 34” x 78” (1

Nos.)

Ambient temperature + 380C

Cooling unit model LST 065-HGM 022

Capacity 8400 btu/hr at 100C SST at 380C

Ambient temperature.

Cooling unit type Air cooled, spilt type

Density of panels 40 ± 2 Kg/cubic meter

Type of compressor Hermetic

Electric Supply 230V/1Ph/50Hz

Compressor run time 16 Hours

Refrigerant R 22

Door Type Heavy duty hinges

Door Frame construction All accessories like light switch,

temperature indicator are fitted on the

door frame.

Construction of the door 1. Flush fir with FRP Door perimeter.

2. Door closure and sweep Gasket.

3. The door should contain magnetic

gaskets to rest on stainless steel strip

on door frame.

4. The stainless steel strip should

contain door heater to prevent Frost

Formation on the door.

5. Digital Temperature indicator, light

switch and wiring connecting the

same should be concealed inside the

panels.

Panel Assembly sealing PVC gaskets between adjacent wall

panels to form Tight Joint.

Temperature indicator Digital Temperature indicator.

Compressive strength at 10% 2-6 Kg/Square meter deformation.

Adhesive Strength 2.9 Kg/Square meter.

Dimensional Variation < 2% (48 Hours)

Closed cell content 90-95%

Thermal Conductivity 0.019-0.022 W/m.deg.c

Water absorption 1 w/v

Safety latch at door Swing type

Blowing agent R-141B (Non CFC)

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.

Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-1. Compliance/Deviation statement comparing the specification of the quoted model

to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS.

(Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: UV-Spectrophotometer (II Derivatives) Qty :- 1 Nos.

Item No:- 19 (119)

Specification

Wavelength range 190 to 1100nm

Spectral bandwidth 1nm (190 to 1100nm)

Wavelength display 0.1-nm increments

Wavelength accuracy ± 0.3nm

Wavelength repeatability ± 0.1nm

Photometric system Double Beam

Photometric range Absorbance :- -0-3 Abs

Transmittance: 0% to 200%

Photometric accuracy ± 0.01 Abs (1.0Abs)

Photometric repeatability Less than ± 0.01Abs (1Abs)

Measuring Modes

Photometric Mode:- Single wavelength or at

multiple (up to 3) wavelengths.

Spectrum Mode:- Wavelength scanning, peak

detection and area calculations.

Quantitation Mode/derivative mode:-

Wavelength scan with the Derivatives modes;

combinations of wavelengths of 1 to 3 and the

third, fourth, or even up to the seventh order

derivative modes and calibration curve with the

resolution of overlapping peaks.

Kinetics Mode:- dealings the change of

absorbance as a function of time.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.Name of Equipment: UV Spectrophotometer (II derivatives). Qty:-1 Nos.

Item No:- 19 (119)

Specification asked for Specification Offered.

Wavelength range 190 to 1100nm

Spectral bandwidth 1nm (190 to 1100nm)

Wavelength display 0.1-nm increments

Wavelength accuracy ± 0.3nm

Wavelength repeatability ± 0.1nm

Photometric system Double Beam

Photometric range Absorbance :- -0-3 Abs

Transmittance: 0% to 200%

Photometric accuracy ± 0.01 Abs (1.0Abs)

Photometric repeatability Less than ± 0.01Abs (1Abs)

Measuring Modes

Photometric Mode:- Single wavelength

or at multiple (up to 3) wavelengths.

Spectrum Mode:- Wavelength

scanning, peak detection and area

calculations.

Quantitation Mode/derivative mode:-

Wavelength scan with the Derivatives

modes; combinations of wavelengths of

1 to 3 and the third, fourth, or even up

to the seventh order derivative modes

and calibration curve with the resolution

of overlapping peaks.

Kinetics Mode:- dealings the change of

absorbance as a function of time.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.

Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-1. Compliance/Deviation statement comparing the specification of the quoted model

to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS.

(Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: Bio Safety Cabinet (Biocontainment work station). Qty :- 1 Nos.

Item No:- 20 (138)

Specification

ISO class 5, NSF international standard of A2 type bio-safety cabinets (Formerly

B3 type floor mounted biosafety workstation with following features).

Material :- Stainless steel 304 or thicker steel should be used for bulk head,

work table and for drain pan below the table.

Size :- 4’ x 2’ of HEPA bioclean hyperbaric work space.

Door :- Fully openable toughened glass front door with counterweight

arrangement.

Cleanliness level :- Class 100 or less (US FED STD 209E) or ISO5

Airflow regine:- HEPA filtered air with down flow of 100 FPM. 70% of air can be

recirculated in the workspace after filtration. 30% discarded

through exhaust after disinfection/filtration. Modification of

direction of flow with above properties is acceptable. Return air

plenum should be under negative pressure.

Noise level: - Low.

HEPA filters :- EU 13 grade, HEPA filters with 99.9% efficiency on 0.3 micron

challenge. Return air should also be adequately safe.

Power supply: - 220 Volt single phase 50Hz to suit Indian condition.

Additional features:- Germicidal UV lamp, sealed white light of more than

200lux in the work area, two 5/15 amp electrical points to

connect loop steriliser, vortex, gas connection with knobs,

low noise blowers for supply and exhaust, air pressure

monitor, failure alarm and indicator.

Installation should include ducting.

To be quoted as option:- Electrically operated multiple loop steriliser.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI

(Annexure-VI)CENTRAL INSTITUTE OF FISHERIES EDUCATION

(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.Name of Equipment: Bio Safety Cabinet (Biocontainment work station). Qty:-1Nos.

Item No:- 20 (138)

Specification asked for Specification Offered.

ISO class 5, NSF international standard of A2 type bio-safety cabinets

(Formerly B3 type floor mounted biosafety workstation with following

features).

Material :- Stainless steel 304 or thicker steel should be used for bulk

head, work table and for drain pan below the table.

Size :- 4’ x 2’ of HEPA bioclean hyperbaric work space.

Door :- Fully openable toughened glass front door with counterweight

arrangement.

Cleanliness level :- Class 100 or less (US FED STD 209E) or ISO5

Airflow regine:- HEPA filtered air with down flow of 100 FPM. 70% of

air can be recirculated in the workspace after

filtration. 30% discarded through exhaust after

disinfection/filtration. Modification of direction of flow

with above properties is acceptable. Return air

plenum should be under negative pressure.

Noise level: - Low.

HEPA filters :- EU 13 grade, HEPA filters with 99.9% efficiency on

0.3 micron challenge. Return air should also be

adequately safe.

Power supply: - 220 Volt single phase 50Hz to suit Indian condition.

Additional features:- Germicidal UV lamp, sealed white light of more

than 200lux in the work area, two 5/15 amp

electrical points to connect loop steriliser,

vortex, gas connection with knobs, low noise

blowers for supply and exhaust, air pressure

monitor, failure alarm and indicator.

Installation should include ducting.

To be quoted as option:- Electrically operated multiple loop steriliser.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-1. Compliance/Deviation statement comparing the specification of the quoted model

to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS.

(Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: Research Grade Rheometer. Qty :- 1 Nos.

Item No:- 21 (139)

Specification

Application Research Grade Rheometer with porous carbon air bearing for

low torque control operation.

Should have Optical encoder for accurate measurement of

angular displacement.

Data display The system may be stand alone but for data acquisition, analysis

software may be provided. PC should not be quoted. (The

configuration of PC required may be indicated)

Motor The system should have advanced drag cup motor or non-contact

induction motor or any other motor with very low inertia and

should be possible to operate under Controlled Stress &

Controlled Strain mode

Cooling system Necessary peltier temperature control system would be preferred.

Any external cooling for precise measurement may be acceptable

Measurement geometries The geometries should include Cone & Plate, Parallel Plate for

characterizing fluids, creams, gels, oils etc. One set of parallel

plate and a set of cone and plate of 2cm dia should be quoted.

The 4cm dia should be quoted as option

Torque Range 0.1µN.m to 150 mN.m

Torque Resolution 0.001 µN.m [1]

Motor Inertia 18 µN.m.s

Angular Velocity Range CS -0 to 300 rad/s

Angular Velocity Range CR 0.1µ rad/s to 300 rad/s

Frequency Range 1µ rad/s to 100Hz

Displacement Resolution 0.4 nrad

Step Change in Velocity 25 ms

Step Change in Strain 60 ms

Bearing Type Air bearing Thurst

Temp Range -20 °C to 150 °C

Measurements

Oscillation Mode Tests:

i. Torque/Stress sweep (linear or log) at

single frequency

ii. Frequency sweep (linear or log) at single

torque

iii. Frequency sweep (linear or log) at single

strain

iv. Strain/angular displacement sweep

(linear or log) at single frequency

v. Temperature sweep at single

frequency/torque

vi. Superimposed stress oscillation and

steady shear

vii. Superimposed strain oscillation and

steady shear

viii. Multiple simultaneous frequencies

superimposed on above modes

Flow Mode Tests:

i. Controlled stress or

torque sweeps.

ii. Controlled rate (1/s) or

speed (rad/s) sweeps.

iii. Stress stepped flow.

iv. Equilibrium stress

stepped flow (ensures material has time to respond to

each level of stress).

v. Temperature sweeps at

constant stress or rate.

vi. Squeeze flow and pull

off.

Creep Mode Tests:i. Constant stress creep

and recovery.

ii. Automatic sensing of

steady state during creep test.

Stress relaxation

Moisture trap Provision to cover sample during run

Other accessories Oil less compressor with air and oil filter and drying assembly

(Good quality local make is acceptable)

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.Name of Equipment: Research Grade Rheometer. Qty:-1Nos.

Item No:- 21(139)

Specification asked for Specification Offered.

Application Research Grade Rheometer with porous

carbon air bearing for low torque control

operation.

Should have Optical encoder for

accurate measurement of angular

displacement.

Data display The system may be stand alone but for

data acquisition, analysis software may

be provided. PC should not be quoted.

(The configuration of PC required may

be indicated).

Motor The system should have advanced drag

cup motor or non-contact induction

motor or any other motor with very low

inertia and should be possible to operate

under Controlled Stress & Controlled

Strain mode

Cooling system Necessary peltier temperature control

system would be preferred. Any external

cooling for precise measurement may be

acceptable

Measurement

geometries

The geometries should include Cone &

Plate, Parallel Plate for characterizing

fluids, creams, gels, oils etc. One set of

parallel plate and a set of cone and plate

of 2cm dia should be quoted. The 4cm

dia should be quoted as option

Torque Range 0.1µN.m to 150 mN.m

Torque Resolution 0.001 µN.m [1]

Motor Inertia 18 µN.m.s

Angular Velocity

Range CS

0 to 300 rad/s

Angular Velocity

Range CR

0.1µ rad/s to 300 rad/s

Frequency Range 1µ rad/s to 100Hz

Displacement

Resolution

0.4 nrad

Step Change in

Velocity

25 ms

Step Change in Strain 60 ms

Bearing Type Air bearing Thurst

Temp Range -20 °C to 150 °C

Measurements

Oscillation Mode Tests:

i) Torque/Stress sweep (linear or log) at

single frequency

ii)Frequency sweep (linear or log) at

single torque

iii)Frequency sweep (linear or log) at

single strain

iv)Strain/angular displacement sweep

(linear or log) at single frequency

v)Temperature sweep at single

frequency/torque

vi)Superimposed stress oscillation and

steady shear

vii)Superimposed strain oscillation and

steady shear

viii)Multiple simultaneous frequencies

superimposed on above modes

Flow Mode Tests:

i) Controlled stress or torque sweeps.

ii) Controlled rate (1/s) or speed (rad/s)

sweeps.

iii) Stress stepped flow.

iv) Equilibrium stress stepped flow

(ensures material has time to respond to

each level of stress).

v) Temperature sweeps at constant

stress or rate.

vi) Squeeze flow and pull off.

Creep Mode Tests:i) Constant stress creep and recovery.

ii) Automatic sensing of steady state

during creep test.

Stress relaxation

Moisture trap Provision to cover sample during run

Other accessories Oil less compressor with air and oil filter

and drying assembly (Good quality local

make is acceptable)

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-1. Compliance/Deviation statement comparing the specification of the quoted model

to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS.

(Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: Semi Automatic Vacuum Seamer for Cans (alongwith vacuum Pump)

Item No:- 22 (140) Qty :- 1 Nos.

Specification

Production Capacity 1 Can/ minute.

Feeding Manual

Display Digital display

Can type (Can Dia) Appropriate for Easy to open can of size 307*109

Size (Height) Adjustable height

Vacuum level needed 5 m bars

Other specification Should to equipped with appropriate vacuum switch and pressure

switch.

Necessary safeguard for workers safety.

Indian electrical condition 220 V, 50-60 Htz.

Note- Vendors are requested to attach the Technical compliance statement with respect to

Above specification as per Annexure-VI

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.Name of Equipment: Semi Automatic Vacuum Seamer for Cans (alongwith vacuum Pump)

Item No:- 22 (140) Qty:-1Nos.

Specification asked for Specification Offered.

Production Capacity 1 Can/ minute.

Feeding Manual

Display Digital display

Can type (Can Dia) Appropriate for Easy to open can of size

307*109

Size (Height) Adjustable height

Vacuum level needed 5 m bars

Other specification Should to equipped with appropriate

vacuum switch and pressure switch.

Necessary safeguard for workers safety.

Indian electrical condition 220 V,

50-60 Htz.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-1. Compliance/Deviation statement comparing the specification of the quoted model

to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS. (Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: Inverted Research Microscope Qty :- 1 Nos.

Item No:- 23 (135)

Specification

1. Stand: - Rugged and sturdy Inverted stand with low positioned co-axial coarser and fine focus

knobs with harmonic focusing. Fine focus should have 1 micron scaling. It should

have built-in electronic power supply for 12V/100W illuminator with conveniently

positioned ON/OFF switch and regulating knob. It should have a side port on the left

hand side for mounting 35mm SLR camera/Scientific Digital camera. The side port

should have two beam splitting positions for (1) 100% light for observation and (2)

80% for documentation and 20% for observation.

2. Optics: - Microscope should have infinity colour corrected optics with high contrast and

resolution. The microscope should be suitable for bright field / phase contrast and

should be upgradable for Epi-Fluorescence techniques, DIC and DIC for plastic

vessels.

3. Nosepiece:- Focusable Sextuple revolving objective nosepiece (should accommodate upto 6

objectives) mounted on ball bearing with highly precise click stops. The nosepiece

should have slots for DIC sliders.

4. Stage:- Large specimen stage app. 250x230mm plate with attachable stage of travel range

130 x 85 mm. There should be common mounting frame to hold Petri dishes of size

35-60 mm and specimen slides.

5. Binocular Tube:- Binocular tube 450C with field of view 23mm on the microscope stand with

swiveling eyepiece tubes with I.P.D. adjustable range 55-75 mm.

6. Illumination:- Built-in illumination to the stand with 12 V / 100 W tungsten halogen lamp. The

lamp should be easily changeable. Filters for ground glass bleu and green filter

should be quoted. The power supply should be adaptable to voltages 90-250V.

7. Condenser:- Long working distance Condenser with aperture value of 0.55 with turret

comprising aperture diaphragm for bright field, phase stops Ph1, Ph2 and Ph3

and provision to attach DIC prisms and plasDIC diaphragms.

8. Objectives:- Long working distance objectives with high contrast and resolution common for

bright field, fluorescence, phase contrast and DIC technique for samples in plastic

containers.

Plan achromatic objectives 5x/0.12, 10x/0.25 Ph1 and LD objective

20x/0.30 Ph1 and LD Plan-neofluar Objective 40x/0.50 Ph2 should be quoted.

9. Eyepieces:- Wide field focusing eyepieces with 23mm field of view with soft rubber eyecups

and should be suitable for spectacle wearers. It should be marked with ± 5 diopter

settings. The eyepieces should be suitable for graticule insertion.

10. Camera:- More 14 Mega pixel digital camera with appropriate mounting attachment should be

quoted.

11. Accessories (Quoted as Option):- Research grade peltier-cooled monochrome camera for

low intensity fluorescent image along with the software,

interface for computer and other components required for

image capturing and processing.

Graticule for the eye piece.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.Name of Equipment: Inverted Research Microscope. Qty:-1 Nos.

Item No:- 23 (135)

Specification asked for Specification Offered.

1. Stand Rugged and sturdy Inverted stand with low positioned

co-axial coarser and fine focus knobs with harmonic

focusing. Fine focus should have 1 micron scaling. It

should have built-in electronic power supply for

12V/100W illuminator with conveniently positioned

ON/OFF switch and regulating knob. It should have a

side port on the left hand side for mounting 35mm SLR

camera/Scientific Digital camera. The side port should

have two beam splitting positions for (1) 100% light for

observation and (2) 80% for documentation and 20% for

observation.

2. Optics Microscope should have infinity colour corrected optics

with high contrast and resolution. The microscope

should be suitable for bright field / phase contrast and

should be upgradable for Epi-Fluorescence techniques,

DIC and DIC for plastic vessels.

3. Nosepiece Focusable Sextuple revolving objective nosepiece

(should accommodate upto 6 objectives) mounted on

ball bearing with highly precise click stops. The

Nosepiece should have slots for DIC sliders.

4. Stage Large specimen stage app. 250x230mm plate with

attachable stage of travel range 130 x 85 mm. There

should be common mounting frame to hold Petri dishes

of size 35-60 mm and specimen slides.

5. Binocular Tube

Binocular tube 450C with field of view 23mm on the

microscope stand with swiveling eyepiece tubes with

I.P.D. adjustable range 55-75 mm.

6. Illumination Built-in illumination to the stand with 12 V / 100 W

tungsten halogen lamp. The lamp should be easily

changeable. Filters for ground glass bleu and green filter

should be quoted. The power supply should be

adaptable to voltages 90-250V.

7. Condenser Long working distance Condenser with aperture value of

0.55 with turret comprising aperture diaphragm for bright

field, phase stops Ph1, Ph2 and Ph3 and provision to

attach DIC prisms and plasDIC diaphragms.

8. Objectives Long working distance objectives with high contrast and

resolution common for bright field, fluorescence, phase

contrast and DIC technique for samples in plastic

containers.

Plan achromatic objectives 5x/0.12, 10x/0.25 Ph1 and

LD objective 20x/0.30 Ph1 and LD Plan-neofluar

Objective 40x/0.50 Ph2 should be quoted.

9. Eyepieces Wide field focusing eyepieces with 23mm field of view

with soft rubber eyecups and should be suitable for

spectacle wearers. It should be marked with ± 5 diopter

settings. The eyepieces should be suitable for graticule

insertion.

10. Camera More 14 Mega pixel digital camera with appropriate

mounting attachment should be quoted.

11. Accessories (Quoted as Option)

Research grade peltier-cooled monochrome camera for

low intensity fluorescent image along with the software,

interface for computer and other components required

for image capturing and processing.

Graticule for the eye piece.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-1. Compliance/Deviation statement comparing the specification of the quoted model

to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS.

(Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: High Speed Refrigerated Centrifuge. Qty :- 1 Nos.

Item No:- 24 (137)

Specification

Floor Model, High Speed Refrigerated Centrifuge with 20,000 rpm or more and

50,000g or more.

Fixed angle Rotor for 250ml x 4,30,000g and 50ml x 4,18,000g to be included. Both should be in one rotor with adaptor.The temperature range should be :- -20 to 400C.

Drive system should include high torque brushless high frequency motor.

Nine stage acceleration and deceleration.

Centrifuge should have foldable liquid crystal display.Centrifuge should be with non contact imbalance protection device and real

time control.

Automatic RCF calculation and RCF integration should be possible.

Self locking rotor and automatic identifications of rotor should be standard.

System should maintain the low temperature within the rotor chamber.

Automatic rotor cover status detector should be available.Centrifuge should also be capable of using various other fixed angle rotors,

swing rotors and continuous flow rotor. The list of these rotors to be included in

your offer.

Instrument to work with single phase 230V AC / 50 Hz power supply.

Instrument should have CE marking for electrical safety.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.Name of Equipment: High Speed Refrigerated Centrifuge. Qty:-1Nos.

Item No:- 24 (137)

Specification asked for Specification Offered.

Floor Model, High Speed Refrigerated Centrifuge with 20,000 rpm or

more and 50,000g or more.

Fixed angle Rotor for 250ml x 4,30,000g and 50ml x 4,18,000g to be included. Both should be in one rotor with adaptor.The temperature range should be :- -20 to 400C.

Drive system should include high torque brushless high frequency

motor.

Nine stage acceleration and deceleration.

Centrifuge should have foldable liquid crystal display.

Centrifuge should be with non contact imbalance protection device

and real time control.

Automatic RCF calculation and RCF integration should be possible.

Self locking rotor and automatic identifications of rotor should be standard.

System should maintain the low temperature within the rotor chamber.

Automatic rotor cover status detector should be available.Centrifuge should also be capable of using various other fixed angle

rotors, swing rotors and continuous flow rotor. The list of these rotors

to be included in your offer.

Instrument to work with single phase 230V AC / 50 Hz power supply.

Instrument should have CE marking for electrical safety.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.

Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-1. Compliance/Deviation statement comparing the specification of the quoted model

to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS.

(Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: Flow Meter Qty :- 1 Nos.

Item No:- 25 (148)

Specification

Flow Meter comprising with 125 mm impeller 0.27 m.

Suspension set.

Control Display Unit.

35 m supervision cable.

0.75 m tall fin

Suspension bar & Conversion Unit.

Velocity range :- 0.03 to 10 m/s.

Accuracy :- ± 1.5% readings above 0.15 m/s & ± 0.004 m/s above 15 m/s.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.Name of Equipment: Flow Meter. Qty:-1Nos.

Item No:- 25 (148)

Specification asked for Specification Offered.

Flow Meter comprising with 125 mm impeller 0.27 m.

Suspension set.

Control Display Unit.

35 m supervision cable.

0.75 m tall fin

Suspension bar & Conversion unit.

Velocity range :- 0.03 to 10 m/s.

Accuracy :- ± 1.5% readings above 0.15 m/s & ± 0.004 m/s above

15 m/s.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-1. Compliance/Deviation statement comparing the specification of the quoted model

to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

SIGNATURE WITH STAMP OF THE BIDDERS.

(Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: ELISA Reader Qty :- 1 Nos.

Item No:- 26 (161)

Specification

Multiskam-FC.

Wave length range 340-850 nm.

8 Position filter.

Accessories:- Attachment of Computer & Colour Laser Jet Printer.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.Name of Equipment: ELISA Reader. Qty:-1Nos.

Item No:- 26 (161)

Specification asked for Specification Offered.

Multiskam-FC

Wave length range 340-850 nm.

8 Position filter.

Accessories:- Attachment of Computer & Colour Laser Jet Printer.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.

Note :- Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-1. Compliance/Deviation statement comparing the specification of the quoted model

to the required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

NOTE :- The Rates may be quoted for delivery, Installation & Demonstration at CIFE, Kolkata Center, 30-GN Block, Sector-V, Salt Lake City, Kolkata-700 091 (W.B.)

SIGNATURE WITH STAMP OF THE BIDDERS.

(Annexure-V)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Name of Equipment: PCR Unit Qty :- 1 Nos.

Item No:- 27 (207)

Specification

Interchangeable Block Selection : Up to 8

Temperature Control Mode:- Block, Tube.

Temperature control Range:- 40C - 990C.

Heating Rate:- 400C/ Sec, Cooling Rate:- 30C.

Temp Control Accuracy:- ± 0.50C @ 950C

± 0.30C @ 720C

± 0.20C @ 550C

± 0.80C @ 950C

± 0.50C @ 720C

± 0.50C @ 720C

± 0.40C @ 550C

Heating rate Maximum:- ± 0.30C Second.

Cooling Rate Maximum:- ± 0.20C Second.

Hot lid Temperature :- Adjustable, 1000C to 1100C.

Digital Display :- 20*2 Character LED.

Maximum no. of Cycle :- 99 cycle.

Maximum Segment / Cycle :- 5.

No. of programme :- 99 files.

Power supply :- AC220V, 50Hz, 600VA.

Dimension :- 470*340*260mm, 18.5*13.4*10.2*.

Net Weight :- 10 Kg.

Printer Connector :- RS232.

Maximum Steps:- 16.

Gradient :- 300C Maximum, 10C Minimum.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-VI

(Annexure-VI)

CENTRAL INSTITUTE OF FISHERIES EDUCATION(Deemed University) I.C.A.R.VERSOVA, MUMBAI-400 061.

ANNUEXURE TO SCHEDULE TO TENDER(to be returned by Bidders along with the Tender duly completed and Signed)

Technical Compliance Statement.Name of Equipment: PCR Unit. Qty:-1Nos.

Item No:- 27 (207)

Specification asked for Specification Offered.

Interchangeable Block Selection : Up to 8

Temperature Control Mode:- Block, Tube.

Temperature control Range:- 40C - 990C.

Heating Rate:- 400C/ Sec, Cooling Rate:- 30C.

Temp Control Accuracy:- ± 0.50C @ 950C

± 0.30C @ 720C

± 0.20C @ 550C

± 0.80C @ 950C

± 0.50C @ 720C

± 0.50C @ 720C

± 0.40C @ 550C

Heating rate Maximum: ± 0.30C Second.

Cooling Rate Maximum: ± 0.20C Second.

Hot lid Temperature : Adjustable, 1000C to 1100C.

Digital Display : 20*2 Character LED.

Maximum no. of Cycle : 99 cycle.

Maximum Segment / Cycle : 5.

No. of programme : 99 files.

Power supply : AC220V, 50Hz, 600VA.

Dimension : 470*340*260mm, 18.5*13.4*10.2*.

Net Weight : 10 Kg.

Printer Connector: RS232.

Maximum Steps: 16.

Gradient : 300C Maximum, 10C Minimum.

Note- Vendors are requested to attach the Technical compliance statement with respect to Above specification as per Annexure-V.Note: - Mark (YES) if specification offered is as per tender or better. If not, specify the specification offered.

An item-by-item commentary on the purchaser’s Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provision of the Technical Specifications.

(Technical literatutre/brouchers/manuals should be attached along with this format)

Please Note:-1. Compliance/Deviation statement comparing the specification of the quoted model to the

required specifications. This statement should also give the last page of the technical literature where the relevant specification is mentioned.

2. Bids must have supporting documents (technical) literature of copies of relevant pages from the service manual or factory test (data) for the points noted above, failure regarding which may result in rejection of bid.

NOTE :- The Rates may be quoted for delivery, Installation & Demonstration at CIFE, Lahli via Anwal, Rohtak (Haryana), Pin-124 411