2
7/29/2019 Choke Manifold WFT110454 http://slidepdf.com/reader/full/choke-manifold-wft110454 1/2 weatherford.com 1 © 2009 Weatherford. All rights reserved. 6647.01 Surface Well Testing Choke Manifold Weatherford’s choke manifold is typically located on the rig oor and provides exible and variable ow control and well shut-in capability upstream of the process and measurement equipment during well test operations. The ow path on one side of the manifold has an adjustable choke and is used during well cleanup or drawdown operations until a stable ow condition has been reached. The opposite side of the manifold houses positive, xed-bean chokes that provide accurate ow control for predetermined ow rates under stable conditions.  A full-bore bypass is incorporated through the center of the manifold and can be used when choking downstream at the heater or open-ow conditions.  Applications Offshore and land operations Drillstem tests Well cleanups Production/well tests Well shut-ins at surface Features, Advantages and Benets Positive xed- and adjustable-choke boxes and full-bore bypass allows maximum operational exibility and control. Positive choke changeouts can be made quickly ofine. Low-torque metal-to-metal sealing on all gate valves provides increased reliability and ease of operation. Four-point lifting sling and integral forklift pockets provide exiblility to handling and movement.

Choke Manifold WFT110454

Embed Size (px)

Citation preview

Page 1: Choke Manifold WFT110454

7/29/2019 Choke Manifold WFT110454

http://slidepdf.com/reader/full/choke-manifold-wft110454 1/2

weatherford.com 1 © 2009 Weatherford. All rights reserved. 6647.01

Surface Well Testing

Choke Manifold Weatherford’s choke manifold is typically located on the rig

oor and provides exible and variable ow control and well

shut-in capability upstream of the process and measurement

equipment during well test operations. The ow path on one

side of the manifold has an adjustable choke and is used

during well cleanup or drawdown operations until a stable ow

condition has been reached. The opposite side of the manifold

houses positive, xed-bean chokes that provide accurate ow

control for predetermined ow rates under stable conditions.

 A full-bore bypass is incorporated through the center of the

manifold and can be used when choking downstream at the

heater or open-ow conditions.

 Applications

• Offshore and land operations

• Drillstem tests

• Well cleanups

• Production/well tests

• Well shut-ins at surface

Features, Advantages and Benets

• Positive xed- and adjustable-choke boxes and full-bore

bypass allows maximum operational exibility and control.

• Positive choke changeouts can be made quickly ofine.

• Low-torque metal-to-metal sealing on all gate valves provides

increased reliability and ease of operation.

• Four-point lifting sling and integral forklift pockets provide

exiblility to handling and movement.

Page 2: Choke Manifold WFT110454

7/29/2019 Choke Manifold WFT110454

http://slidepdf.com/reader/full/choke-manifold-wft110454 2/2

weatherford.com 2 © 2009 Weatherford. All rights reserved. 6647.01

Weatherford products and services are subject to the Company’s standard terms and conditions, available on request or at weatherford.com. For more information contact an authorized Weatherford representative.

Unless noted otherwise, trademarks and service marks herein are the property of Weatherford. Specications are subject to change without notice. Weatherford sells its products and services in accordance with the

terms and conditions set forth in the applicable contract between Weatherford and the client.

Surface Well Testing

Choke Manifold 

 Specications

Model CM-10000-5V Model CM-15000-5V

Size (in.) 3-1/16

Number of valves 5

Maximum working pressure

(psi/MPa)

10,000

69

15,000

103

Test pressure

(psi/MPa)

15,000

103

22,500

155 

Operating temperature range(°F/°C )  –20 to 250 –29 to 121

Service conditions H2S/CO

2

ID (nominal bore)

(in/mm)

3-1/16

77.79

Outside dimensions

L × W × H (ft/m)

6.29 × 8.00 x 3.12

1.92 × 2.44 × 0.95 

Floor to centerline of bore

(ft/m)

1.40

0.43

 Approximate weight

(lb/kg )

6,750

3,062 

Upstream connection 3-in. Fig 1502 union female3 1/16-in. API 16BX hub

Downstream connection 3-in. Fig 1502 union male

Needle type adjustable choke size (in.) 8/64 to 128/64

Fixed choke bean sizes (in.)4/64 to 64/64 at 4/64 increments

72/64 to 128/64 at 8/64 increments

Full bore bypass Yes

 Applied codes

 API 6A (PR1, PSL-2)

NACE MR-01-75

Material class - DD

Temperature class - P+U

DNV 2.7-3

Options• Sampling and chemical injection points

• Other sizes and specications available on request