Chlorsys Electro-Chlorination Package
TM
Advantage of Technology • Effective protection against macro and micro-fouling (continuous and shock dosing)• Safe and reliable, also eliminating the handling and storing of hazardous chlorine based chemicals.• Ideal to be used as an anti-bacterial agent (disinfection)• Suitable for offshore installations where chlorine is required for fine filter water injection packages.• Minimum environmental impact (chlorine decomposes back into common salt again)• No heavy metal pollution (e.g. copper or lead)
Application field • Offshore platforms• Chemical Industry• Desalination plants• Waste water plants• Power plants
Anti-fouling system for offshore and marine applicationChlorsys Electro-Chlorination PackageTM
Electro-Chlorination Package CHLORSYS TM 2 - 3
Description of chlorination Package ❶ Inlet seawater control system ❷Electrolysers ❸Hypo storage tank❹Hydrogen de-gassing Blower ❺Hypo Dosing system ❻DC power Supply ❼Acid Tank ❽ Trolley
Anti-fouling system for offshore and marine applicationChlorsys Electro-Chlorination PackageTM
Electro-Chlorination Package CHLORSYS TM 2 - 3
Anti-fouling system for offshore and marine applicationChlorsys Electro-Chlorination PackageTM
Electro-Chlorination Package CHLORSYS TM 4 - 5
Main Component of Chlorination Package 1. The ElectrolyserThe electolyser consist of bi-polar anode and cathodes that are arranged to form multiple cells. Electrolyser material is titanium. Anodes required a coating of mixed material oxides(MMO) of the platinum group of metal
Efficiency comparison of electrolyser type
Yellow lineBlue lineRed line
Violet line
TypeBi-PolarBi-Polar
Mono PolarTubular
CompanyKwangsan
ABC
DC kW/NaOCI per 1kg3.7~4.4 kW/kg4.5~6.25 kW/kg4.5~6.25 kW/kg6.2 ~8 kW/kg
Anti-fouling system for offshore and marine applicationChlorsys Electro-Chlorination PackageTM
Electro-Chlorination Package CHLORSYS TM 4 - 5
2. ACID Washing systemDuring electrolysis, calcium carbonate and magnesium hydroxide will deposit on the cathode, a process commonly referred to as “scaling” It is universal phenomenon with all electro-chlorinators. ACID washing system is easy remove by flushing the 5 % diluted hydrochloric acid. ACID washing system is possible for periodic operation by user, the process takes approx. 1 hour.
3. Hypo Dosing systemHypo dosing pump type using the piston or diaphragm or centrifugal mag-drvie dosing pumpQuantity of dosing pumps is 1 x 100 % or 2 x 100 % and consists of duty and stand-by functional.Hypo dosing pump controlled by proportional flow or programmable on-line residual Cl2 control Hypo dosing system is operation of the continuous and shock dosing at the anti-bio-fouling.
Acid Tank
Hypo dosing Pump로
Main Component of Chlorination Package4. Hypo Storage Tank & Hydrogen de-gassing BlowerHydrogen is always generated during electro-chlorination and is directly proportional the amount of generated chlorine.Hydrogen is the safely diluted and removed with blower air from blower fan.There are usually 2 blower fans, a duty and stand-by fan.
Purpose of Chlorination PackageWhere seawater is used for cooling purposes, sodium hypochlorite is an economical and safe method to produce this powerful biocide and disinfecting agent in offshore and marine applications.For offshore applications, Electro-Chlorination Package (anti-fouling systems) are built as complete skid-mounted units with each component stringently tested prior to assembly, ready for immediate shipment, installation and commissioning.
Our Electro-Chlorination package system is• Local or remote controlled• Safe or hazardous areas systems• Unlimited chlorine capacities (from a few kilograms to several tons of Cl2/day)• Manual or automatic acid cleaning systems• ACID-free self-cleaning electro-chlorination systems, e.g. tubular or reverse polarity automatic self-cleaning electrolysers
Anti-fouling system for offshore and marine applicationChlorsys Electro-Chlorination PackageTM
Electro-Chlorination Package CHLORSYS TM 6 - 7
Hydrogen de-gassing blower
Hypo Storage Tank
Specification of KwangSan Chlorination Package
Anti-fouling system for offshore and marine applicationChlorsys Electro-Chlorination PackageTM
Electro-Chlorination Package CHLORSYS TM 6 - 7
KS-CHPK-20KS-CHPK-50KS-CHPK-100KS-CHPK-150KS-CHPK-200KS-CHPK-300KS-CHPK-400KS-CHPK-500KS-CHPK-1000KS-CHPK-2000
ModelRequired seawater
(m3/hr)
Required electric power(kWh) (AC)
DimensionL × W × H (m)
2050
100150200300400500
10002000
0.832.084.176.258.3312.516.720.841.783.3
0.421.042.083.104.176.258.30
10.4220.8041.70
8302,0834,1676,2508,33412,50016,66820,83341,66783,333
4151,0422,0833,1254,1676,2508,33210,41720,83341,667
4102031416283104208410
2.3 x 1.0 x 1.53.2 x 1.2 x 1.74.4 x 1.5 x 2.04.6 x 1.6 x 2.54.8 x 1.7 x 2.75.0 x 1.8 x 2.75.2 x 1.9 x 2.85.5 x 2.0 x 2.95.7 x 2.1 x 3.06.0 x 2.4 x 3.1
Disinfection amount (m3/h)
1ppm 2ppm
Capacity
kg Cl2 / Day kg Cl2 / hr
Diagram of Chlorination Package
Need more information?Contact us
1173-2, Jisa-dong, Gangseo-gu, Busan, KoreaTel: +82-51-974-6301 Fax: +82-51-974-6305www.kwangsan.com E-mail : [email protected]