BROAD Indoor Units have obtained international
certicates of ISO, CE, ETL and so on
BROAD Town, 410138,Changsha, China www.broad.com
Tel: +86-731-84086175 Fax: 84086387 ter [email protected]
纸80g
2011.07 First edition NO.:10,000
BY169-11 C 2011
In order to protect forests and
water resources, please follow
us to use thin, unlaminated
printing paper.
100g
FUNCTION
Air conditioning, air purication
STRUCTURE
Fan coils + electrostatic
cleaner + intelligent control
system+ movable metal shell
COOLING CAPACITY
2.7kW ~130kW
(7℃ chilled water and 65OC
hot water can be supplied)
UNIQUE ADVANTAGES
● Exposed installation of fan
coils, movable shell which
enables easy dust cleaning &
bacteria killing, eliminates the
"air-conditioning disease"
● Equipped with electrostatic
cleaner purifying indoor air
effectively
● Equipped with CO2 sensor
monitoring oxygen deciency
● Inverter-controlled fan, very
energy efcient
● 100% steel structure,
automobile stylish quality
baking nish
● Plug and play concept
BROAD AIR CONDITIONING
INDOOR UNITS
Design & Model selection Manual
Central Air Conditioning Terminals
2011.07 EN
8/15/2019 Chiller Fans
2/8
1
Electrostaticcleaning device
A / C W
. o u t l e t
C o n d
e n s a t e
o u t l e t
A / C W
. i n l e t
CO2 Sensor
UNIQUE TECHNOLOGIES
BROAD Air Conditioning indoor units are Central Air Conditioning Terminal products. Their unique air quality
technologies have rewritten the century-old air conditioning history. They have met needs of modern architecture
with their exquisite & various models, easy installation & maintenance.
ElectrostaticCleaner
ActiveCarbon lter
Coarse lter
Fan
Coils
Electrostatic dust cleaning:Tungsten
laments of electrostatic cleaners
continuously release high voltage static
electricity. All particles in the air are
positively charged, then adsorbed by
negative plates. Particles tinier than
human cells and pollens are ltered,
which can protect the respiratory system,
and reduce drastically the cancer risks.
Electrostatic Bacteria Killing: Tungsten
laments of electrostatic cleaners
continuously release high voltage static
electricity at 6,000v. It kills instantlybacteria, viruses, and can stop all kinds
of airborne diseases.
Active Carbon Filter eliminates
formaldehyde: traps all kinds of toxic
gases like benzene, nicotine, etc.
AIR PURIFICATION PRINCIPLE :
·
·
·
2
INDOOR UNIT PRODUCT OVERVIEW
Note: 1.Areas (recommended m2) need engineers to do detailed calculation, it's for your reference.
2.Super energy efcient building refers to envelop enclosure with thermal insulations and heat recovery
fresh air which have reached the highest building levels .
3.Large Model, Super large Model: areas suitable for a 4~6m height building.
Mo del C od e A /C cap aci ty Ar ea s (r eco mm end ed) m2 Dimensions
(L×W×H)
mm
Cooling
kW
Heating
kW
Common
building
Energy
Efcient
building
Super energy
efcient
building
Flat DC3.6 3.6 5.3 20 40 80 520x320x940
DC5.4 5.4 8.1 30 60 120 520x320x1310
DC7.2 7.2 10.8 35 75 150 520x320x1500
DC12 12 18 50 100 200 520x320x2250
Oval DQ5.4 5.4 8.1 30 60 120 1670x320x700
DQ12 12 18 50 100 200 2600x320x840
Horizontal
Long-range
DE12 12 18 70 150 300 2250x360x520
Vertical
long-range
DF12 12 18 60 120 250 520x360x2250
Curve AD2.7 2.7 4 12 25 40 1560x195x340
Large EH18 18 27 70 150 300 380x840x2590
EH25 25 37.5 100 200 400 380x840x3200
EH40 40 60 150 300 650 380x840x5000
Super large EC60 60 90 250 500 1000 2000x1900x3920
EC130 130 195 400 800 1600 3800x1900x3920
8/15/2019 Chiller Fans
3/8
3
PRODUCT STRUCTURE
CONTROLLER
Outdoor temp
Indoor temp
Indoor humidity
Cooling
Heating
Set temp
A/C W inlet temp
A/C W outlet temp
Real-time cooling capacity (heating capacity)
A/C W ow rate
Indoor CO2 level (monitor oxygen deciency)
Fan frequency(10~50Hz)
Five-position switch
Infrared window
Green light - Operation
Red light – Alarm
Light off when unit off
Timer
OK
Remotecontrol
Controller
Clean air outlet
Auto vent
Dirty air inlet
CO2 sensor
Humidity sensor
Indoor temp sensor
Coarse lter
insect mesh
Positively chargedtungsten flaments
Negatively charged
aluminum plates
Active carbon lter
Coilsthe only shared part withconventional products
Motor valve
adjust room temp and avoid A/Cwater circulation when the unit is off
to save pump electricity
Stainless steel bellows
Manual valveadjust ow rate, for shutoff inmaintenance
A/C W outlet
A/C W inlet
Manual valvebalance water system, for shutoff inmaintenance
Water lter
Condensate outlet
Heat meterconsists of ultrasonic ow meterand thermometer
Water pan
Fan
Electrostatic
cleaner
Air purication
system
Air conditioning
system
Inverter fan
C H T1K
4
CLEANING ELECTROSTATIC CLEANER
Easy to take out electrostatic cleaner
Open shell by a slight touch
Use detergent and water to wash
To maintain constant purication efciency, once the cleaner is very dusty, it has to be taken out and cleaned
(once per month). Easy to wash with detergent or ultrasonic cleaner. Each time it only takes a few minutes.
8/15/2019 Chiller Fans
4/8
5
LOAD
QUANTITIES
ENERGY SAVING
COMFORT
OPTIONS
MODEL SELECTION GUIDANCE
Load selection cannot be roughly estimated, it is
closely related to building thermal insulation level
rather than building areas.
If a fast model selection is needed, please refer to P 2
“Areas(recommended m2)”.
One unit per room is recommended.
More units might be recommended for spacious room
with more furniture.
Inverter-controlled fan cuts energy consumption
drastically at low load operation.
Actually, air conditioners are running at low load
during 90% operation time.
Optional pre-set energy saving mode saves energy by
20%~30%.
Air cannot be blown directly to people.
Inverter-controlled fan makes the quiet operation.
Remote control: adjust temperature and air flow,
USD13/pc. One pc is recommended for one room,
for a room equipped with multiple fan coils, one is
recommended for 3 pcs. In public rooms like hotels
can use control panel instead.
Color: products have “standard color” please read
“Rated Parameters”, if customers prefer different colors,
additional 7% will be billed. It is also optional to choose
special panels, for instance, stainless steel, titanium, gold-
plating, price is high, lead time is longer.
Model Code A/C Capacity A/C water Fan Air owm3 /h
A/Ctubemm
Condensate tube mm
N.W.kg
Ship. Wkg
Standardcolor
CoolingkW
HeatingkW
Circu-lationkg/h
Resis-tancekPa
Powerdemand W
PowerconsumptionW
Flat DC3.6 3.6 5.3 442 30 130 25~98 650 Φ16 Φ16 33 40 White
DC5.4 5.4 8.1 663 40 140 30~105 970 Φ22 Φ16 45 54
DC7.2 7.2 10.8 884 40 140 40~110 1300 Φ22 Φ16 52 63
DC12 12 18 1473 50 260 60~200 2160 Φ28 Φ16 73 86
Oval DQ5.4 5.4 8.1 663 40 140 30~105 970 Φ22 Φ16 46 56 Wine red
DQ12 12 18 1473 50 350 70~280 2160 Φ28 Φ16 88 102
HorizontalLong-range
DE12 12 18 1473 50 450 100~360 2160 Φ28 Φ16 79 92 White
VerticalLong-range
DF12 12 18 1473 50 450 100~360 2160 Φ28 Φ16 79 92 White
Curve AD2.7 2.7 4 331 30 50 15~40 540 Φ16 Φ16 24 28 White
Large EH18 18 27 2210 60 450 130~380 2700 Φ28 Φ22 238 252 White
EH25 25 37.5 3100 6 0 620 180~520 3750 Φ35 Φ22 298 3 15
EH40 40 60 4960 60 1070 310~850 6000 Φ42 Φ22 478 505
Super large EC60 60 90 7440 70 4800 960~4080 10800 Φ 42 Φ22 800 860 Silvergrey
E C130 130 195 16100 80 6730 1950~5640 23400 Φ 76 Φ28 1300 1410
RATED PARAMETERS
1. Rated conditions for cooling: outlet/inlet water temp14/7℃, inlet air dry bulb temp 27℃, wet bulb temp 19.5℃
Rated conditions for heating: outlet/inlet temp 55 ℃/65℃, inlet air dry bulb temp 21℃.
2. External residual pressure of Super large series EC60 & EC130: 90Pa and 150Pa respectively(in operation with ducting system).
3. Standard at model designed as right side air blow, optional to choose “left side air blow” when an order is placed, letter
B must be added after the model.
4. Standard super large series designed as direct blow, optional to choose “ducting”, letter F must be added after the model.
Notes:
PERFORMANCE CURVES
Air ow vs. Air pressure ( for super large series ducting model)
Chilled water owrate vs. Cooling capacity
C o ol i n g c a p a ci t y %
C o ol i n g c a
p a ci t y %
E x t er n al s t at i c pr e s s ur e ( P a )
Flowrate %
100
95
90
85
80
75
7050 60 70 80 90 100
Chilled water temp vs. Cooling capacity
Return air temp.
10℃9℃8℃7℃6℃5℃
140
120
100
8060
4023 24 25 26 27 28
Air ow %
300
100
200
0 60 100 140
ECF130
ECF50
●
●
●
●
●
●
●
●
●
●
●
6
320
1 0 0 ~ 6 0 0
185
2 6B
35
520
88 6 5
1 3 0
(illustrated model is 5.4kW)
Air inlet
Air outlet
4 bolts M8
L
A/C W supply A
A/C W return A
Condensate
Power input
FLAT MODEL (DC3.6、DC5.4、DC7.2、DC12)
Magnicent, economic (as per cooling capacity), suitable for all kinds of buildings.
Model L A B
DC3.6 940 Φ16 48
DC5.4 1310 Φ 22 60
DC7.2 1500 Φ 22 60
D C1 2 2 25 0 Φ 28 7 0
Dimensions (mm, the same
on the following pages)
Note: If it can’t be wall-mounted,
choose oor bracket, 5% price more.
8/15/2019 Chiller Fans
5/8
7
1100 2040
60 70
2 30 2 22
368 720
251259
1670 2600
3 0 0
7 0 0 1
0 5
8 2
2 4 4
2 8 7
8 4 0
Power input 6 bolts M8 A/C W return A/C W supply Condensate
22 28 22 28 16Air inlet
Air outlet
1 4 0 0 ~ 1 9 0 0
3 2 0
(illustrated model is 5.4kW)
OVAL Model (DQ5.4,DQ12)
Magnificent & stylish. Choices with special elegant panel (as mirror-style stainless steel,
brushed stainless steel, even titanium plate).
Note: Two data of dimension for DQ5.4 and DQ12 respectively.
8
Adjustable nozzles, suitable for densely-stuffed rooms.
HORIZONTAL LONG-RANGE MODEL (DE12)
Air outlet(adjustable
any direction)
Air inlet 65 Power input A /C W r et ur n 1 30
26
1 2 0
1 8 5
7 0
8 8
1 7 0 0 ~ 2 0 0 0
5 2 0
3 6 0
A/C Wsupply
4 bolts M8
2250
Condensate
28
16
28
8/15/2019 Chiller Fans
6/8
9
Air outlet(adjustable
any direction)
Air inlet
70 1 3 0
2 2 5 0
2 6 35
185
3 0
4 bolts M8
520
88360
1 0 0 ~ 1 5 0 0
6 5
Power input
A/C W supply
A/C W return
Condensate
28
28
16
Adjustable nozzles, suitable for densely-stuffed rooms.
VERTICAL LONG-RANGE (DF12)
10
Air outlet direct to the lobby
(adjustable)
Return water tube
28
Supply water tube
4 bolts M12
Condensate
Power input
Maintenance access Maintenance access
35 42
28 35 42
20
70
135
342
380
2 5 9 0
3 2 0 0
5 0 0 0
8 0
9 0
7 7 0
Air outlet(adjustable) Air inlet
(illustrated model is 25kW)
840 200
Suitable for open space, nozzles can be adjusted, especially suitable for airport, supermarket. Either
placing independently or against the wall, the body can be used for billboards.
LARGE MODEL (EH18、EH25、EH40)
Note:There are 3 dimensions:
EH18,EH25 and EH40
8/15/2019 Chiller Fans
7/8
11
SUPER LARGE MODEL (EC60、EC130)
Suitable for large open space, nozzles can be adjusted, can be connected to ducting system. Body can
be used as billboards.
12
Note: Two data of dimension for
EC60 and EC130 respectively.
Air outlet Air outlet Air outlet Air outlet
2000 3800 1900
300
3 9 2 0
1 6 0
Air outlet direct
to the lobby
(adjustable)
Paper filter
Coil
Coarse filter
Electrostaticcleaner
Air inlet Air inletAir inlet Air inlet
(illustrated model is EC60)
Maintenanceaccess
Maintenanceaccess
Maintenanceaccess
Maintenanceaccess
Power input
Condensate 22 1 50 20 0Φ 28Φ
A/C W supply
A/C W return
42Φ 76Φ
42Φ 76Φ
8/15/2019 Chiller Fans
8/8
13
Air inlet
Air outlet
A/C W s upply A/C W retur n
4 bolts M8
Power input Condensate
16
195
71 1791560
3 4 0
1 1 5
4 8
2 0 0 ~ 3 0 0
16
16
Low position installation, low position air outlet, super energy-efcient
CURVE MODEL (AD2.7)
14
1. Installation procedures
INSTALLATION TIPS
Pre-installed piping and wiringDuring the construction, A/C water supply & return tubes (with
pre-installed valve), condensate tubes, power supply cable,
signal wire shall be implemented to the location of indoor
units.Water pumps must be started circulation for 5 days at
least so that impurities inside tubes can be collected.
Shell installationIndoor units are to be installed after the room decoration.
Handle them with care to avoid any damage. Locate and
drill holes on the wall against the screw holes on the shell
back rst, then insert expansion bolts and mount the unit.
(Large model must be equipped with anchor bolts whereas
super large model may not apply them) .
Tube connectionConnect the pre-installed water supply tube, water return
tube and condensate tube to the i ndoor units. Check
&clean impurities of the water lter.Water return & supply
tubes can be connected with exible stainless steel bellows
Power connectionLead power cable from the wiring terminal to indoor power
supply. The power cable must comply with the local codes
and standards.
Controller installation(most models have installedcontrollers before shipment).The controller can be installed on a supporter supplied with
the unit, or lead 3×0.15mm2 control cable from the wiring
terminal and install the controller onto the wall nearby. The
location should be convenient to operate.
4. Tips for piping connection
5. Electric wiring(List of site work)
Item Installationposition
Material Applicable Materialsource
Scope
Externalpower
Wiringterminal
3×1.0mm2
3×1.5mm2
3×2.5mm2
5×4.0mm2
5×6.0mm2
2.7~7.2kW
9~18kW
25~40kW
60kW
130kW
User Installer
Controller Wiring
terminal
3×0.15mm2
communicationcable
All BROAD Installer
Notes:
All electric materials and methods for installation must comply
with the local codes and standards.
Specific connection refers to “Exterior wiring diagram”
attached with unit.
All the units must be of reliable grounding.
Stainless steel bellows (BROAD supply)
Outdoor thermometer installationLead a 2×0.3mm2 cable from indoor unit wiring termi nal.
Install the sensor outside the window and avoid direct
sunshine. The length of the cable should be less than 30m.
(If thermometer is separately purchased from BROAD,it must
be mounted in the sunshade box from BROAD).
3. Tips for shell installation
8. Air purication commissioningCompare particles from the outlet and inlet with particle
detector (or Particles instrument).
Take out the electrostatic cleaner after operating for a day
and check dust collection.
If not, there might be some faults. Please notify BROAD or
BROAD authorized service provider.
6. Power on inspection
7. A/C hydraulic balance commissioningStart up all indoor units in the whole building for cooling or
heating operation.
Check that whether the output of each indoor unit is
consistent. Use an infrared thermometer to test whether the air
outlet temp from each indoor unit is the same.
Turn up its ow regulating valve or turn down valves of nearby
indoor units if the air temp from an indoor unit cannot reach
the target. Repeat the adjustment till a hydraulic balance is
reached.
Generally the valve openness of those indoor units closer to
the chiller should be smaller.
After completion of whole building installation, keep the
chilled water pump running continuously for min. 5 days to
accumulate impurities at each lter. Wash the l ters before
indoor units are installed.
2. Tips for piping and wiring pre-installation
Pre-installed valve (BROAD supply)
W. return valve
Elbow for
temporary
circulation
W. supply valve
Water lter
Note: Please follow the marks to install and make sure not
to mix up the supply & return W. tubes, otherwise
coils will be clogged!
Fix the reserved location of pipeline wire and installation
height, then Install pipeline.
Copper tubes must be adopted in supply/ return water
tubes. Low temperature brazed welding is recommended
in connecting the tubes (450℃ hot air guns welding). The
A/C W. tubes should be covered with 30mm-80mm rubber
plastic cold insulation material and non-metal tubes can
be used for condensate tubes.
BROAD pre-installed valve should be installed at the end of
pipeline(as shown below). Water supply valve is also a ow
regulating valve which can balance the ow rate of each
indoor unit. It also has a shutoff function which facilitates
lter washing. The valve must be reset each time.
●
●
●
●
Keep the shell horizontal with no more than 2 mm gradient.
The expansion bolts should be strong enough to support at
least 3 times the weight of the shell (as there might be an
impact when the cover is opened).
Shut off the pre-installed valves (water return/ supply
valves), take out and wash water lter, then x them back.
Take out the bellows for temporary circulation and send it
back to BROAD.
Connect the pre-installed valves with indoor units by 2
stainless steel bellows of proper length.
The condensate tube must be with a certain gradient.
After the installation is completed, check the settings in
indoor unit controller item by item according to “Parameter
Setting” from User's Manual.
Pay special attention to the fan motor noise, outdoor/
indoor temperature and CO2 concentration.
Check indoor unit and lighting on/off through controller or
remote control.
●
●
●
●
●
●
●
●
●