72
Chesterfield, Missouri Tenant Signage Criteria January 28, 2019

Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Chesterfield, Missouri

Tenant Signage CriteriaJanuary 28, 2019

Page 2: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

GENERAL SIGNAGE CRITERIA A. Introduction………………………………………………………………………………………………..…....3B. Submittals & Approvals………………………………………………………………………….…………….3C. Fabrication & Installation Requirements………………………………………………………………...…...4D. Non-Conformance……………………………………………………………………………………………...5E. Guarantee……………………………………………………………………………….………………..…….5F. Insurance Requirements…………………………………………………………………………...……….....6G. Sign Attachment Details…………………………………………………………………………………….…6H. Storefront Signage…………………………………………………………………………………..………....6I. Primary Tenant Identification Signage………………………………………………………………….........7

PRIMARY TENANT IDENTIFICATION SIGNAGEStorefront Tenant Identification Signage Location Keyplan………………………………………………...…...8Building Type Elevation………………………………………………………………………………………….….9

STOREFRONT SIGN TYPE A……………………………………………………………………………………12EXHIBIT A.1 - Typical Storefront Sign - Type A ………………………………………..…………….......13EXHIBIT A.2 - Single Line Detail..…………………………………………………………………………..14EXHIBIT A.3 - Double Line Detail..………………………………………………………………………….15EXHIBIT A.4 - Mounting Detail……………………………………..………………………………….…....16

STOREFRONT SIGN TYPE B……………………………………………………………………………………17EXHIBIT B.1 - Typical Storefront Sign - Type B ……..…………………………………………...…...….18EXHIBIT B.2 - Storefront Sign Type B Details... ………..………………………………………..…...…..19EXHIBIT B.3 - Mounting Detail……………………………………………………………………………...20

STOREFRONT SIGN TYPE C………………………………………….………………………………………..21EXHIBIT C.1 - Typical Storefront Sign - Type C …………..……………………………………...………22EXHIBIT C.2 - Storefront Sign - Type C Details.………..………………………………………..…...…..23EXHIBIT C.3 - Mounting Detail ……………………………………………………………………………..24

SECONDARY TENANT IDENTIFICATION SIGNAGESIGN TYPE D- Blade Sign…………………………………………………………………………………..…....25

EXHIBIT D.1 - Typical Blade Sign Detail…………………………………………………………..............26

SIGN TYPE E- Entry Door/Storefront Window Signage………………………………………………………..27

PERIMETER TENANT IDENTIFICATION SIGNAGEPerimeter Tenant Identification Signage Location and Size Keyplan ………………………………………...29

SIGN TYPE F/F1...…………………………………………………………………………………………………30EXHIBIT F.1 - Typical Perimeter Signage - Type F….....……….…………………………………...…...31EXHIBIT F.2 - Single Line Detail…………………………………………………………………...............32EXHIBIT F.3 - Typical Perimeter Signage - Type F1...……………...…………………..…………...…...33EXHIBIT F.4 - Double Line Detail…………………………..………………………………………............34

SIGN TYPE G/G1….………………………………………………………………………………………………35EXHIBIT G.1 - Typical Perimeter Signage - Type G/G1.....…..……………………………………...…...36EXHIBIT G.2 - Perimeter Signage Type G/G1 Detail……………………………………...………..........37

SIGN TYPE G2…………………………………………………………………………………………………….38EXHIBIT G2.1 - Typical Tower Signage - Type G2..……………………………………………………...39EXHIBIT G2.2 - Tower Signage - Type G2 Details..……………………………………………………....40

SPECIFIC SIGNAGE CRITERIA1. Service/Delivery Signage…………………………………………………………………………….......452. Temporary Signage ……………………………………………………………...……………………....453. Prohibited Signs…………………………………………………………………………………………...454. Food Court Signage……………………………………………………………………………………....46

General Signage Criteria 2

Page 3: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

5. Elevation at Food Tenant Counter ……………………………………………………….……….........47

General Signage Criteria 3

Page 4: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

A. IntroductionThis criteria has been developed to guide each Tenant to an imaginative signage solution. The guidelines established herein will ensure that Tenant identification is of consistent quality and is compatible with the architectural character of the Center. Each proposed sign will be evaluated on the design’s excellence and compatibility with neighboring signs and the overall character of the Center’s signage/graphics. Tenant’s signage depends on location and architectural conditions at the storefronts within the Center.1. Storefront Tenant Identification Sign Options for Internal Areas of Center:

a. Type A: Logos/Logos with Text: Combination face/halo lit cabinet type, routed faces with push-thru acrylic letters, as approved by Landlord.

b. Type B: Fabricated non-illuminated aluminum letters mounted to electrical raceway with concealed LEDs for wall wash.

c. Type C: Fabricated individual reverse channel letters with halo illumination. 2. Secondary Tenant Identification Sign Options for Internal Areas of Center:

a. Type D: Blade sign mounted above storefront entry doors (or centered between sets of doors)

b. Type E: Entry doors/Storefront signage3. Perimeter Tenant Identification Sign Options:

All perimeter/tower signs MUST include engineered sign drawings indicating structural support for sign.

a. Type F: Fabricated individual reverse channel letters with halo illuminationDouble Line: Secondary Text - routed push-thru acrylic letters in 10” electrical raceway

b. Type G: Tower Signage only - Individual face lit channel lettersc. Type G2: Tower Signage only - Logo/Logos with Text: Face lit cabinet type,

routed faces with push-thru acrylic letters OR backed with plex, as approved by Landlord.

NOTE: LEDs ARE NOT TO BE VISIBLE ON SIGN. ALL ILLUMINATION TO BE EVEN LIGHTING WITHOUT ANY “HOTSPOTS” ON SURFACES.

B. Submittals and Approvals1. All Tenant signage is subject to the Landlord’s written approval. The Landlord’s

approval shall be based on the following criteria:a. Design, fabrication, and method of installation of all signs shall conform to

this sign criteria.b. This sign criteria shall conform to the design standards of the Center in

harmony with adjacent signage conditions.2. The Tenant agrees to conform to the following procedures and submission

requirements to secure the Landlord’s approval:a. Submit one (1) set of detailed sign design, shop drawings: Simon Property

Groupb. Sign drawings are to be prepared by a reputable state licensed Sign

Contractor or as required to be licensed by the local authorities.c. Sign drawings must include a ⅛” scaled storefront drawing illustrating the

proposed sign design and all dimensions as they relate to the storefront elevation of the Tenant’s premises.

d. Sign drawings must also include a min. 1” = 1’-0” sign elevation and section through sign indicating construction and attachment methods and illumination details.

e. Letters must be accurately dimensioned and spaced.f. Sign external finish designations and types of materials must be included

with the sign drawings. g. Lighting from cantilevered point lights is not allowed.h. Unless Landlord has received the above described drawings and information

in the quantities set forth above, the Landlord will not approve the Tenant’s exterior sign.

3. All drawings marked “Revise and Resubmit” must be resubmitted with the required corrections prior to fabrication. Only after all drawings have been marked “Approved as Noted” and after permit is obtained may the fabricator

General Signage Criteria 4

Page 5: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

proceed with fabrication per approved drawings.4. The Tenant and Sign Contractor will not be permitted to commence installation of

the exterior sign unless all of the following conditions have occurred:a. A stamped set of final drawings reflecting the Landlord’s approval shall be on

file in the Landlord’s office.b. Tenant and their Sign Contractor shall be responsible for the securing of all

applicable sign permits required by the local authorities prior to fabrication of the signs. The Landlord’s stamped approval is required on all plans prior to the application for permit. ALL signs, including temporary tenant signs, must be submitted first to the City of Chesterfield. The application and 5 copies of both the sign and elevation with dimensions must be included (no fee required for this). Once approved, the City will give back 4 copies for Sign Contractor to submit to St. Louis County for the building permit for the sign.

c. The City of Chesterfield issued sign and electrical permits, as well as a stamped set of drawings reflecting the Landlord’s approval prior to sign installation. The Sign Contractor/Tenant shall be responsible for all inspections.

d. The Landlord must be notified 48 hours in advance prior to the sign installation, by contacting the on-site Center Manager.

e. The Landlord must receive a Certificate of Insurance from the Sign Contractor actually performing the installation.

5. The Landlord reserves the right to revise this Signage Criteria in accordance with City of Chesterfield’s Sign Ordinance for up to thirty (30) days before the Tenant’s Rent Commencement date. However, this Signage Criteria may be revised at any time if so required by any government agency having jurisdiction over its contents.

6. In the event the Tenant changes their sign at any time during the term of their lease, Tenant must comply with any future modifications, revisions, or changes, which have been made to the Sign Criteria for the Center after the execution of their Lease Agreement.

7. The Tenant shall pay for all signs, their installation (including any required electrical connection back to the J-box and any secondary J-box required) and all other labor, materials, and future maintenance. Tenant will provide dimensional, waterproof blade sign, including their design with storefront sign submittal for review. Tenant will also be responsible for the fabrication and installation of the blade sign bracket to match existing at Center, if none exists at their space.

8. The Tenant and their Sign Contractor are responsible for understanding this Sign Criteria and conforming to its requirements.

9. The Tenant shall be ultimately responsible for the fulfillment of all requirements and specifications, including all applicable building and electrical codes.

10.All signs shall be reviewed for conformance with this criteria and overall design quality. Approval or disapproval of sign submittals based on aesthetic of design shall remain the sole right of the Landlord.

C. Fabrication & Installation RequirementsThe fabrication and installation of all signs shall be subject to the following restrictions:1. All signs mounted on concrete substrate are to be attached by pin-mounting or as

shown on detailed exhibits. Spacers to be painted to match adjacent building wall color.

2. Ladders, installation equipment and installation crews are not permitted to lean on building, awnings and storefront. All installation equipment must be freestanding type to avoid contact with or damage to building or storefront. Motorized man lift is allowed with Landlord’s prior approval. Rubber wheeled lifts must have wheel padding or white tires to prevent marks on paving areas. Vehicles are not permitted on pedestrian streets.

3. Tenant’s Sign Contractor is required to contact the onsite Center Manager prior to installation of signage and again at completion so acceptance can be determined.

4. Installation crews are responsible for establishing a safety zone around their work area. Tenant Signage crews must display caution tape and safety cones and apply these safety devices to the surface of walkways and doors. Electrical cords cannot be run outside of this safety zone.

5. All penetrations of the building structure required for sign installation shall be sealed in a

General Signage Criteria 5

Page 6: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

watertight condition and patched to match adjacent finish. Spacers must be painted to match building color. No PK housings allowed. Photos of correct installation of signs, from inside and out, are required to be provided within 48 hours of install.

6. Each Tenant, or their Sign Contractor, shall be responsible for the repair of any damage to the building caused by the installation of said Tenant’s sign. Particular attention must be made in and around the access panels into any canopy areas. If required, repainting these areas will be back-charged to the Tenant.

7. The installation Sign Contractor is responsible for removing all debris and cleaning the work area after installation is complete. Sign Contractor shall protect existing wall surfaces and nearby awning structures during sign installation.

8. The Sign Contractor must check sign to ensure proper illumination. Tenant is not allowed to disconnect from Landlord’s time clock override relay.

9. Each Tenant shall be responsible for the performance of its Sign Contractor. Any damage to surrounding walls or surfaces made by signage contractor shall be repaired at their expense

10. Each Tenant shall be responsible for the installation and maintenance of its sign. Should the Tenant’s sign require maintenance or repair, Landlord shall give Tenant fifteen (15) days written notice to effect said maintenance or repair. Should Tenant fail to do so, Landlord shall effect said maintenance or repair and Tenant shall reimburse Landlord within ten (10) days of receipt of invoice.

11. Tenant to use Landlord provided storefront J-box to wire storefront signage back to designated circuit. If no J-box exists, it is Tenant’s responsibility to provide and connect to Landlord’s timeclock.

12. UL labels MUST be placed on signs/sign letters according to local municipality's requirements. All other sign elements, including transformers, power supplies, and/or ballasts must also be labeled according to the most current National Electric Code standards, as well as any additional state requirements that apply. Secondary wiring must be completed by one of the permitted methods dictated by the most current NEC.

13. Interior raceways may be required to conceal wiring and transformers on interior of Tenant space if open ceiling condition exists or if it is a perimeter sign installation, depending on sign location and conditions. Raceway must be painted to match wall. Field survey conditions.

14. In some cases exterior weatherproof raceways may be required to cover any exposed electrical components above rooflines & roof membrane penetrations must be sealed. Penetration & raceway sealing must be coordinated with LL’s roofing contractor to preserve roof warranty. Contact Center Management for roofing contractor’s contact information.

15.If a Tenant sign change is absolutely necessary during winter months when temperatures drop below 45 degrees, upon existing sign removal, Tenant is required to patch holes and use color matched paint to do a “temporary” touch up until temperature warms up above 45 degrees PRIOR to new sign installation. Then during warmer weather, Tenant’s contractor must return to repaint sign band to Landlord’s satisfaction. Sign must be covered during repairs. This work must be completed in a timely fashion when warmer weather occurs.

D. Non-Conformance1. No field installation changes are permitted without first notifying the Landlord in

writing. If any sign is changed as to placement, location and/or size, which differ from the approved sign plan, Tenant and/or Sign Contractor will be responsible for repair, change, and/or relocation of sign to proper placement at their expense.

2. Any sign that is installed by Tenant which is not in conformance to the approved drawings shall be corrected by Tenant within 15 days after written notice by Landlord. In the event Tenant’s sign is not brought into conformance within said 15 days, then the Landlord shall have the option to correct non-conforming sign at Tenant’s expense.

E. GuaranteeEntire display shall be guaranteed by Sign Contractor for one (1) year from date of installation against defects in material and workmanship. Defective parts shall be replaced without charge.

F. Insurance RequirementsSIMON/WOODMONT DEVELOPMENT, LLC; ST. LOUIS PREMIUM OUTLETS MEMBER, LLC, SPIRIT OF ST. LOUIS OUTLETS, L.P.; are to be named as Additional Insured on all policies.

General Signage Criteria 6

Page 7: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Premium Outlets Simon, as Certificate Holder, shall be included on all policies as an additional insured/loss payee. Before commencing the work, the Contractor shall procure and maintain at its own expense, until final completion and acceptance of the work, the following minimum insurance forms and with insurance companies acceptable to the Owner:1. Worker’s Compensation Insurance for statutory obligations imposed by Worker’s

Compensation or Occupational Disease Laws, including, where applicable, the United States Longshoremen’s and Harbor Worker’s Act, the Federal Employer’s Liability Act, and the Jones Act. Employers’ Liability insurance shall be provided with a maximum limit of $1,000,000.00 per disease, $5,000,000.00 policy limit by disease.

2. Comprehensive Automobile Liability Insurance with the following minimum limits of liability:

Bodily Injury Liability $2,000,000 - Each OccurrenceProperty Damage Liability $2,000,000 - Each Occurrence

The insurance is to apply to all owned, non-owned and hired automobiles used by the Contractor in the performance of work.

3. General Liability, Contractual Liability and Products/Completed Operations Liability Insurance covering all operations required to complete the work with the following minimum limits of liability:

Bodily Injury Liability $2,000,000 - Each OccurrenceProperty Damage Liability $2,000,000 - Each Occurrence

The Products/Completed Operations Liability Insurance shall be provided for a period of at least two (2) years after completion of the work.The Contractual Liability Insurance coverage shall insure the performance of the contractual obligations assumed by the Contractor by acceptance of this order, including specifically, but without limitation, the Indemnification provisions of this agreement.

4. Excess Liability (Umbrella):Bodily Injury Liability $2,000,000 - Each OccurrenceProperty Damage Liability $2,000,000 - Each Occurrence

G. Signage Attachment DetailsAll wall penetrations are to be made using one of the approved attachments details as found in this Signage Criteria.

H. Storefront Signage1. All Tenants to have a storefront sign. Sign shall be located only on the spaces and on

the surfaces specially provided for same on the building elevations. Signage type and size shall be dictated by the building type the Tenant is located in as defined in the Building Signage Type Plans and location key plan.

2. Square footage for Tenant wall signs shall be based on the maximum sign lengths and letter heights as defined in the following paragraphs and exhibits.

a. Each Tenant to have:- One (1) primary Storefront sign.- One (1) secondary Blade sign.- An additional exterior wall sign shall be offered to specific Tenants solely

at the Landlord’s discretion for perimeter signage on the exterior of the Center.

b. Subject to Landlord review and approval, specific Tenant locations (such as towers or corner spaces at ends of buildings) with more than one frontage and/or entry may be allowed one sign on each frontage provided architectural treatments at each location can accommodate a sign. If additional signs are allowed, signs located on adjacent building elevations shall be dictated by building signage type location elevations. Tenant is responsible for supply and installation of additional J-box where needed.

c. Sign area and location to be determined by Landlord.d. Letter height on primary storefront single line signs shall be as defined in

the following sections:Note: Consideration for moderate increases to maximum signs or letter heights may be given to Tenants with logotypes which have larger initial capital or dangling letters or other unique features.

General Signage Criteria 7

Page 8: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Specific locations and surrounding architectural treatments can dictate maximum sign height and length, which in some cases may be less than the maximum defined herein.

3. All signs (size, design, type and color) are subject to Landlord’s approval, based on aesthetic and relationship to neighboring Tenant signs.

4. Signs shall be limited to letters designating the store name as set forth in signed lease documents between Tenant and Landlord.

a. Tenant shall display their established registered trade name(s) only.

b. Registered Trademark Symbols are permitted subject to Landlord review/approval of fabrication requirements.

5. The colors and type styles of all signs shall be subject to Landlord’s approval. Established trade logos and signage are required to be used, providing they conform to the criteria described herein. The color of all lettering and/or sign panels shall be compatible with the building color and provide sufficient contrast with the background color of the building wall on which the sign is located.

6. Logo plaque components used in conjunction with individual letters are considered an integral part of the store identity and are included in the calculation of allowable sign area, subject to Landlord’s approval.

7. Individual shop address numerals will be provided and installed by the Landlord on the storefront and rear door of the Tenant space, and are not included in the calculation of allowable wall signage area.

8. No Tenant shall affix or maintain upon any exterior glass or other exterior surface of the storefront, any signs or symbols other than the signs provided for in this criteria.

9. No temporary signs of any nature will be accepted!

I. Primary Tenant Identification SignageTenant’s primary identification sign shall be selected from the following sign types based on the storefront’s location and architectural conditions within the Center’s internal areas.

General Signage Criteria 8

Page 9: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Storefront Tenant Identification Signage Location Keyplan 9

Page 10: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Sign Type: A Tilt-Up Concrete Wall (At Corner)

Logo cabinets as approved by landlord

Sign Type: A Tilt-Up Concrete Wall

Logo cabinets as approved by landlord

Sign Type: A EFIS Wall

Logo cabinets as approved by landlord

Building Type Elevation - Typical 10

Page 11: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Sign Type: B Tilt-Up Concrete Wall

Logo cabinets as approved by landlord

Sign Type: B Tilt-Up Concrete Wall

Logo cabinets as approved by landlord

Sign Type: B Tilt-Up Concrete Wall

Logo cabinets as approved by landlord

Building Type Elevation - Typical 11

Page 12: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Sign Type: C EFIS Wall

Logo cabinets as approved by landlord

Sign Type: C EFIS Wall

Logo cabinets as approved by landlord

Sign Type: C Sign Type: CEFIS Wall EFIS Wall

Logo cabinets as approved by landlord Logo cabinets as approved by landlord

Building Type Elevation - Typical 12

Page 13: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Sign Type A: REQUIRED AT CORNER FEATURE LOCATIONS AND ALLOWABLE AT ALL LOCATIONS IF LOGO ONLY – COMBINATION OF ROUTED ALUMINUM WITH PUSH-THRU ACRYLIC LETTERS OR BACKED WITH PLEX. ALL SIGNS TO HAVE FACE/HALO ILLUMINATION BY MULTI-DIRECTIONAL LEDS.a. Fabricated enclosed weatherproof aluminum box type cabinet with routed

face and push-thru acrylic copy OR backed with plex. Cabinet to have Lexan backing for combination face and halo illumination by brand specific LEDs to create sufficient illumination for sign location with no hot spots.

b. Color of logo box cabinet to be approved by Landlord prior to fabrication and installation. Logos/cabinets shall be contrast in color to wall.

c. Any copy within the logo box cabinet shall be routed from aluminum logo face with push-thru acrylic letters/logo symbol OR backed with plex. Copy/symbol shall be translucent acrylic with frosted finish on face or any color vinyl and ½” reveal. Color selected by Tenant and approved by Landlord. No glue-on allowed.

d. Size of logo will vary depending on elevation and designated sign band area. e. Tenant signs are to be centered on the Tenant's store frontage or between

prominent architectural elements, as dictated by Landlord. f. Length: The length of the individual Tenant signs on internal storefronts shall

be variable. However, the length shall not exceed 75 percent (75%) of Tenant's storefront width, or twenty-four feet (24'-0") in length, whichever of the two result in a smaller sign.

Example: 20' store width x 75% multiplier = 15 feet of allowable sign length. g. Bolts, connectors, sleeves, etc. shall be non-ferrous materials. h. All penetrations thru walls to be watertight. i. Power to Tenant sign circuits is 120 volt.

NOTE: This sign type may be substituted at any elevation for LOGOS only. Any lettering that is separate from the logo element must be designed as the correct sign type indicated for that typical elevation sign band.

Storefront Sign Type A 13

Page 14: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Sign Type A

Sign Type A

Signage Type A Examples

Signage mounting height will be determined at the time of installation by Landlord.

EXHIBIT A.1 - Typical Storefront - Sign Type A 14

Page 15: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

SIGN TYPE A .125 routed aluminum face with push-thru acrylic copy.

Single Line Text No exposed fasteners in face. Cabinet to have face andhalo lighting effect by brand specific LEDs.

Logo with Face/Halo Illumination (Shape varies)

Building face

2½” (min) to 6" (max) 1½” - 2"

1½” to 2" standoff with aluminum.125 routed aluminum facewith push-thru acrylic copy OR backed with plex. No exposed fasteners in face.

Brand specific LEDs on returnfor halo illumination

Aluminum cover over weephole to prevent light leak -(2) two - ¼” weep holesper letter

Aluminum return mechanicallyfastened to Lexan backs

Section Detail

spacers as required; Paint to matchbuilding surface.

³/16" clear Lexan backs withmechanically fastened to returns w/ angle clips & C.S. screws

Brand specific LEDs on back to create sufficient illumination to light face, with no hot spots

Low voltage wire

U.L. shut off switch & rubberboot in cabinet or as requiredfor access

Cabinet to have self contained power supply when applicable, or remote power supply as approved by Landlord.

Logo with Face & Halo Illumination

Note: All bolts, connectors, sleeves, electrical conduits, etc. to be non-ferrous. All penetrations thru tilt-up concrete wall panel to be watertight. LEDs are not to be visible on sign. All illumination to be even lighting without any hotspots on surfaces.

EXHIBIT A.2 - Single Line Details 15

Page 16: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

SIGN TYPE A .125 routed aluminum face with push-thru acrylic copy

Double Line Text No exposed fasteners in face. Cabinet to have face andhalo lighting effect by brand specific LEDs.

LogoText

Logo with Face/Halo Illumination (Shape varies)

Building face

2½” (min) to 6" (max) 1½” - 2"

1½” to 2" standoff with aluminum.125 routed aluminum facewith push-thru acrylic copy OR backed with plex. No exposed fasteners in face

Brand specific LEDs on returnfor halo illumination

Aluminum cover over weephole to prevent light leak -(2) two - ¼” weep holesper letter

Aluminum return mechanicallyfastened to Lexan backs

Section Detail

spacers as required; Paint to matchbuilding surface.

3/16" clear Lexan backs withmechanically fastened to returnsw/ angle clips & C.S. screws

Brand specific LEDs on back to create sufficient illumination to light face, with no hot spots.

Low voltage wire

U.L. shut off switch & rubberboot in cabinet or as requiredfor access

Cabinet to have self contained power supply when applicable, or remote power supply as approved by Landlord..

Logo with Face & Halo Illumination

Note: All bolts, connectors, sleeves, electrical conduits, etc. to be non-ferrous. All penetrations thru tilt-up concrete wall panel to be watertight. LEDs are not to be visible on sign. All illumination to be even lighting without any hotspots on surfaces.

EXHIBIT A.3 - Double Line Details 16

Page 17: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Typical Mounting Details

Stud Framed Wall½” aluminum sleevepainted to match wallsurface, typ.

EIFS wall system

⅜" threaded stainlesssteel rod with steel togglebolt

Metal stud framing, typ.

Seal all interior and exterior wall penetrations

Hollow Wall Anchor Sign Attachmentto Structural Exterior Wall

3/8" dia. all thread stainless steel rod with Zinc plated steel toggle bolt Wings . Bolt length to be determined as required per wall construction.

Letter Mounting Detail at EIFS over Metal Stud Framing

½” aluminum sleevepainted to match wallsurface, typ.

EIFS wall system

⅜" threaded stainlesswedge anchor

Tilt-up concrete wallpanels, typ.

Masonry WallExpansion Sign Attachment to Masonry Constructed Wall

3/8" dia. stainless steel wedge anchor sign attachment to concrete, brick, rock and stone masonry wall installations

Seal all interior and exterior wall penetrations

Letter Mounting Detail at EIFS over Tilt-up Concrete Wall

Masonry Wall ½” aluminum sleeve Expansion Sign Attachmentpainted to match wall to Masonry Constructed Wallsurface, typ.

⅜" threaded stainless wedge anchor

3/8" dia. stainless steel wedge anchor sign attachment to concrete, brick, rock and stone masonry wall installations

Tilt-up concrete wall panels, typ.

Seal all wall penetrations

Letter Raceway Detail at Tilt-up Concrete Wall

Note: All bolts, connectors, sleeves, electrical conduits, etc. to be non-ferrous. All penetrations thru tilt-up concrete wall panel to be watertight. LEDs are not to be visible on sign. All illumination to be even lighting without any hotspots on surfaces.

EXHIBIT A.4 – Mounting Details 17

Page 18: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Sign Type B: NON-ILLUMINATED ALUMINUM CHANNEL LETTERS MOUNTED TO CURVED ELECTRICAL RACEWAY WITH CONCEALED LED MODULES FOR WALL WASH ILLUMINATION

a. Non-illuminated channel letters shall have a maximum depth of 4" (preferred depth = 2½”). Letters shall be fabricated from weatherproof with clear ¼” or ³/16" Lexan backing. All seams shall have continuous welds and be filled.

b. Color of letters preferred as clear coated natural metal (ex: Bronze, brass, and alum: polished, brushed or swirled, etc.), black, or Tenant's corporate colors as approved by Landlord, prior to fabrication and installation.

c. Optional secondary copy line on raceway shall be routed from sign shelf face with push-thru acrylic letters OR backed with plex. Copy shall be translucent acrylic with frosted finish on face or any color vinyl and ½” reveal. Color selected by Tenant and approved by Landlord. No glue-on allowed.

d. Raceway shall be fabricated from .125 min. weatherproof aluminum. Raceway to have a contrasting/complimentary color or weathered finish to letters and wall, which is to be approved by Landlord. All seams to have continuous welds and be filled.

e. Non-illuminated channel letters with wall wash concealed brand specific LED modules, with no hot spots. LED lighting system to be located inside raceway with clear or color acrylic lens over the lighting source.

f. Tenant signs are to be centered on the Tenant's store frontage or between prominent architectural elements, as dictated by Landlord.

g. Length: The length of the individual Tenant signs on internal storefronts shall be variable. However, the length shall not exceed 75 percent (75%) of Tenant's storefront width, or twenty-four feet (24'-0") in sign length, whichever of the two results in a smaller sign.

Example: 20 foot store width x 75% multiplier = 15 feet of allowable sign length. h. Height: 29" maximum sign assembly

Single line: Text letters on shelf shall not exceed 20" in height. The raceway height shall be 9". Double line: Text letters on shelf shall not exceed 20" in height. Secondary copy line located in face of raceway - 6" high maximum. Raceway height shall be 9". The outside assembly edge of letter and raceway height shall not exceed 29". Logo: Logo shall not exceed 24" in height.

i. Bolts, connectors, sleeves, etc. shall be all non-ferrous materials. j. All penetrations thru walls to be watertight. k. Power to Tenant sign circuits is 120 volt.

Storefront Sign Type B 18

Page 19: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Sign Type B

Varies - Maximum 75% of Tenants storefront width

Signage Type B Examples

Signage mounting height will be determined at the time of installation by Landlord.

Storefront Sign Type B EXHIBIT B.1 - Typical Storefront - Sign Type B 19

19

Page 20: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

SIGN TYPE BSingle or Double Line Text 20" high non-iIluminated aluminum

channel letter forms.

Back wall lit with concealed brand specific LED modules at 2 modules per foot mounted to electrical raceway.

TENANTS EC O N D

9" electrical raceway attached to wall

Elevation

Concealed brand specific LEDs

AR Y CO P YOptional secondary copy line on raceway routed fromsign face with push-thru acrylic letters OR backed with plex. Translucent acrylic with frosted finish on face or any color vinyl and ½” reveal. Color by Tenant, approved by Landlord.

12" (max)

Fabricated non-illuminated aluminum,channel letter forms w/ .090face/.063 returns/.1875 Lexan backs, typ. (4" deep max; 2½” preferred)

Back wall lit with concealed brand specific LEDs.

.125" thick (min) weatherproofaluminum electrical raceway whichprojects 12" from wall. Contrastingfinish on raceway. No access panelsallowed at bottom of raceway, typ.

Variable Length 12" (max)

Plan View

4" +10"Max Lexan backer panel, typ.

Clear or color acrylic lens overLED lighting

Secondary electrical supply frommodular 60 power supply.

12" ½” aluminum spacers as required;Raceway Paint to match wall.

Section Detail

Storefront Sign Type B EXHIBIT B.2 - Type B Details 20 20

Page 21: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

3" Brand specific LEDs, with no hot spots 2 modules per foot (uplighting)

3" 1 1/2"

Aluminum LED bracket

Tenant sign mounted to existing concrete tilt-up wall with expansion anchors as required by engineer

Secondary electrical supply from remote Modular 60 power supply 12VDC.

Enlarged Section Detail

Typical Mounting Details

½” aluminum sleevepainted to match wallsurface, typ.

EIFS wall system

⅜" threaded stainlesswedge anchor

Tilt-up concrete wallpanels, typ.

Masonry Wall

Expansion Sign Attachment to Masonry Constructed Wall

3/8" dia. stainless steel wedge anchor sign attachment to concrete, brick, rock and stone masonry wall installations

Seal all interior and exterior wall penetrations

Letter Raceway Detail at EIFS over Tilt-up Concrete Wall

½” aluminum sleevepainted to match wallsurface, typ.

⅜" threaded stainlesswedge anchor

Tilt-up concrete wallpanels, typ.

Seal all wall penetrations

Masonry WallExpansion Sign Attachment to Masonry Constructed Wall

3/8" dia. stainless steel wedge anchor sign attachment to concrete, brick, rock and stone masonry wall installations

Letter Raceway Detail at Tilt-up Concrete Wall Note: All bolts, connectors, sleeves, electrical conduits, etc. to be non-ferrous. All penetrations thru tilt-up concrete wall panel to be watertight.

LEDs are not to be visible on sign. All illumination to be even lighting without any hotspots on surfaces.

Storefront Sign Type B EXHIBIT B.3 - Mounting Detail 21 21

Page 22: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Sign Type C: INDIVIDUAL REVERSE CHANNEL HALO LIT LETTERS WITH LED ILLUMINATION

a. Individual reverse channel letters shall have a maximum depth of 4” (preferred depth = 2½”). Letters shall be fabricated from weatherproof .063 thick aluminum with clear ¼” or ³/16” Lexan backing. All seams shall have continuous welds and be filled.

b. Letter and return color preferred as black or clear coated natural metal (ex: Bronze, brass, aluminum: polished, brushed or swirled, etc) or Tenant’s corporate colors as approved by Landlord, prior to fabrication and installation. All seams to have continuous welds and be filled. 1½” spacers to be painted to match wall/facade color.

c. Tenant signs are to be centered on the Tenant’s store frontage or between prominent architectural elements unless noted otherwise by Landlord.

d. Individual pinned-off, reverse channel letters shall be back lit with brand specific LEDs to create sufficient illumination for sign location with no hot spots. Halo lighting with 2” min to 4” max returns.

e. Length: The length of the individual Tenant signs on internal storefronts shall be variable. However, the length shall not exceed 75 percent (75%) of Tenant’s storefront width, or twenty-four feet (24’-0” max.) in sign length, whichever of the two results in a smaller sign.

Example: 20’ store width x 75% multiplier = 15 feet of allowable sign length.f. Height: 20" high letters for single line sign and 36" high panel for double line

sign, assembly area.Single line: Text letters shall not exceed 20" in height.Double lines: Tenant name letters shall not exceed 20" in height. Overall height not to exceed 36". Second line of copy to be in routed aluminum cabinet with routed face. Cabinet to be combo face/halo lit with LED's and ½” push-thru letters. Logo: Aluminum logos may extend 3" beyond letters above and/or below.

g. Bolts, connectors, sleeves, etc. shall be non-ferrous materials. h. All penetrations thru walls to be watertight. i. Power to Tenant sign circuits is 120 volt.

Storefront Sign Type C 22

Page 23: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Sign Type C

Signage Type C - Examples

Signage mounting height will be determined at the time of installation by Landlord.

EXHIBIT C.1 - Typical Storefront - Sign Type C 23

Page 24: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

SIGN TYPE C Single or Double Line Text

Fabricated aluminum, reverse channel letter forms with halo illumination

TENANTS E C O N D A

10" electrical raceway attached to wall

Elevation

2" to 4"max.

R Y C O P YOptional secondary copy line on raceway routed from sign face with push-thru acrylic letters OR backed with plex. Translucent acrylic with frosted finish on face or any color vinyl and ½” reveal. Color by Tenant, approved by Landlord.

Variable Length

Plan View

2½” (min) to 4" (max)

Fabricated reverse aluminumchannel letter with .090 face/.063 return/.1875 Lexan back

Brand specific LEDs on returnfor halo illumination

Aluminum cover over weephole to prevent light leak -(2) two - ¼” weep holesper letter

Aluminum return mechanicallyfastened to Lexan backs forface/halo illumination

1½” - 2"

1½” to 2" standoff with aluminumspacers as required; Paint to matchbuilding surface.

³/16" clear Lexan backs withmechanically fastened to returnsw/ angle clips & C.S. screws

Low voltage wireU.L. shut off switch & rubberboot in cabinet or as requiredfor access

Secondary electrical source from remotemodular power supply.

Brand specific LEDs on returnsfor face/halo illumination

Section Detail Note: All bolts, connectors, sleeves, electrical conduits, etc. to be non-ferrous. All penetrations thru tilt-up concrete wall panel to be watertight. LEDs are not

to be visible on sign. All illumination to be even lighting without any hotspots on surfaces.

EXHIBIT C.2 - Sign Type C Details 24

Page 25: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Typical Mounting Details

Stud Framed Wall½” aluminum sleevepainted to match wallsurface, typ.

EIFS wall system

⅜" threaded stainlesssteel rod with steel togglebolt

Metal stud framing, typ.

Seal all interior and exterior wall penetrations

Hollow Wall Anchor Sign Attachmentto Structural Exterior Wall

3/8" dia. all thread stainless steel rod with zinc plated steel toggle bolt Wings. Bolt length to be determined as required per wall construction.

Letter Mounting Detail at EIFS over Metal Stud Framing

Masonry Wall½” aluminum sleevepainted to match wallsurface, typ.

⅜" threaded stainlesswedge anchor

Tilt-up concrete wallpanels, typ.

Seal all wall penetrations

Expansion Sign Attachmentto Masonry Constructed Wall

3/8" dia. stainless steel wedge anchor sign attachment to concrete, brick, rock and stone masonry wall installations

Letter Mounting Detail at Tilt-up Concrete Wall

EXHIBIT C.3 - Mounting Detail 25

Page 26: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Sign Type D: BLADE SIGN MOUNTED ABOVE STOREFRONT ENTRY DOORSTenant will fabricate and install one (1) double-faced, weatherproof blade sign. Tenant will be responsible for the fabrication and installation of the blade sign bracket if none currently exists at space.a. The purpose of the blade sign is to identify the store entrance to shoppers

along pedestrian paths. The blade signs shall be located approximately at the center line over store entry doors or between sets of doors.

b. Blade sign shape may vary, but the size of the sign shall be limited to 6 square feet per sign face. The sign panel shall be maximum 36” wide by 24” high (maximum area).

c. Each Tenant will be allowed to use this sign with their logo to complement their individual style, emphasizing their corporate identity and/or product.

d. Painted dimensional letters mounted to blade panel are required to give interest and variety.

e. Tenants must submit blade sign shop drawings with details to Landlord for approval.

f. Sandblasting and wood are prohibited.g. Bolts, connectors, sleeves, etc. shall be all non-ferrous materials. h. Attach blade with locking carabiner style clip available at any hardware

store.

Storefront Sign Type D - Blade Signs 26

Page 27: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

4'- 0"

½” thick aluminum base plate, typ. 4" Adjustable to 18"-24" centers SS threaded support

rods w/ decorative acorn nut fasteners

6"

Aluminum tubular bracketframe w/ powder coatfinish, color Tiger DrylacRAL 9007 Silver Gross49192880

Aluminum platesto tie poles together

Proposed Blade Sign Wall Bracket - Top Elevation

4'- 0"

Slotted tube forsupport rod center adjustments

1'-1½” Adjustable to 24" centers 6½”

2¼” Adjustable to 18" centers 3" square aluminumtube (x1) welded to collar plate, typ.

1" square aluminum tubes (x2) welded to collar plate, typ.

9-1/2" ½” thick aluminum base plate, typ. Wall fasteners as required by engineering review

24"x36" signage panel

max. (by Tenant)

8"

3 1/2" Decorative acorn nut fasteners

Proposed Blade Sign Wall Bracket - Side Elevation

SS threaded support rods w/ decorative acorn nut

5" ½” thick aluminumbase plate, typ.

Blade Sign Wall Bracket - Front ElevationStorefront Sign Type D - Blade Signs

EXHIBIT D.1 - Blade Mounted Detail 2727

Page 28: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Sign Type E: ENTRY DOOR/STOREFRONT WINDOW SIGNAGE a. For the purpose of store identification, the Tenant may propose to the Landlord

a design layout of Tenant name and/or logo in white or black Vinyl Die-Cut Graphics or another color as per Landlord's approval for placement on the inside of entry doors. Each door is permitted one (1) square foot of Vinyl Die-Cut Sign area. The area must be centered 70” from grade or as otherwise directed due to door configurations. Please confirm placement with the Center Management before fabrication and installation.Door Vinyls:

b. For the purpose of additional store identification, the Tenant may also propose to the Landlord a design layout of store name/logo ONLY in black or white Vinyl Die-Cut Graphics or another color, as per Landlord's approval, for placement on the inside of every other (alternating) display window. The maximum permitted area on each window may not exceed one (1) square foot and placement must occur in the centered area measured a minimum of 8” inward toward the window's center from the vertical edges of the window and may not exceed 42” above grade. Window Vinyls:

c. Permanent store signage as part of window background display is limited to one (1) square foot of sign area per one (1) lineal foot of store frontage.

d. Tenant supplied Help Wanted signs are prohibited.e. Help Wanted and other standard information signs as deemed necessary by

Landlord, are provided by Landlord and shall be affixed to the inside left edge of the window immediately adjacent to the right of entry doors and no higher than 48” above grade. Such signage shall only be permitted to be affixed with clear suction cups.

f. Standard information signage icons such as no food, drink, smoking, store hours, etc. shall be provided by Landlord only. Facebook, Twitter, Foursquare shall be provided by Landlord at Tenant request and Tenant expense.

g. Credit Card or check acceptance signs or logos placed on storefront display windows or doors are strictly prohibited.

h. Alarm company stickers shall be limited to one per entry door and be located only at the extreme lower right corner of the glass area on the door.

i. Handicap access is permitted and shall be placed according to ADA or local Storefront Sign Type E - Entry Door/Storefront Window Signage 28

Page 29: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

jurisdiction under the supervision and approval of the Landlord.j. Other than as provided in this criteria and/or the Storefront Criteria, no signage

of any type is permitted to be placed in or affixed to storefront windows or doors. The Landlord reserves the right to require a Tenant, at its expense, to remove any storefront signage it considers to be non-complying or unprofessional.

k. All Tenant signage must be removed upon expiration or earlier termination of the Lease, and the storefront/fascia repaired, all at Tenant’s expense.

Storefront Sign Type E - Entry Door/Storefront Window Signage 29

Page 30: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Tenant Name and/or Logo Vinyl

Perimeter Tenant Signage Type F/F1 30

Page 31: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Perimeter Tenant Signage Type F/F1

Per

imet

er S

ign

Type

F/F

1P

erim

eter

Sig

n Ty

pe F

/F1

Tow

er S

ign

Type

G42

” Hig

h m

ax le

tters

Tow

er S

ign

Type

G1

36” H

igh

max

lette

rs

Tow

er S

ign

Type

G2

42” H

igh

max

alu

min

um lo

go c

abin

et

with

rout

ed a

lum

inum

face

; pus

h-th

ru

acry

lic le

tters

. Cab

inet

to h

ave

com

bina

tion

face

lit/h

alo

illum

inat

ion.

S

ize

will

var

y, b

ut n

ot to

exc

eed

200

sf

Perimeter Tenant Signage Location & Size Key Plan 3031

Page 32: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Sign Type F/F1: PERIMETER TENANT IDENTIFICATION SIGNS - REVERSE CHANNEL LETTERS WITH INTERNAL HALO ILLUMINATION.

a. All perimeter signs (size, design, type and color) are subject to Landlord's approval. b. Square footage for Tenant wall signs shall be based on maximum sign lengths and

letter heights as defined in the following criteria. c. Additional exterior wall signs shall be permitted to Tenants based on the Landlord's

discretion. d. Signs shall include letters and logos designating the store name as stated in signed

lease documents between Tenant and Landlord. e. No temporary signs are to be used. f. No projections outside of each designated sign area are allowed. g. SINGLE LINE TEXT: Tenant logos be internally illuminated channel with reverse

channel halo lit routed face and push- thru acrylic. Colors to be approved by Landlord. Tenant signs with letters outside of logo area to be individual halo lit reverse channel.

h. DOUBLE LINE TEXT: Secondary line of copy to be in routed aluminum cabinet with ½” push-thru acrylic letters. Colors to be approved by Landlord.

i. All logos (size, design, type and color) are subject to Landlord's approval. j. Square footage for Tenant logos shall be based on maximum square footage allowed,

and consideration to maximum sign heights will occur on those sign areas that can accommodate larger logos, however they may not exceed or intrude upon any architectural sign fascia/projection.

k. Select Tenants in the project may be offered one or more such sign(s) at Landlord's discretion.

l. Logo/letter returns shall match the faces, or black. m. All signs shall fit within the architectural frame as indicated herein. n. All signs should establish a facade rhythm, scale and proportion where not currently

existing. o. The size of any sign logo shall be consistent with the proportions of scale of building

elements in the facade. p. Tenant signs shall be mounted as indicated in this criteria.q. Landlord will provide electrical power and conduit to Landlord provided J-box. If not

provided, Tenant shall be responsible to supply and install J-box and any required connections per Building Standard and Landlord specifications. Power provided to perimeter signs is 120 volt.

r. Perimeter signs shall be installed during non-business hours. s. Lighting to be brand specific LEDs. The signs electrical components: power supply,

transformer are to be fully enclosed within a rectangular metal weatherproof aluminum remote raceway.

t. Color of letters must show sufficient contrast to building fascia subject to Landlord's discretion and approval.

u. Bolts, connectors, sleeves, etc. shall be all non-ferrous materials. All penetrations thru walls to be watertight. ALL penetrations must be sealed inside and out. Installer MUST email Landlord photos of front and back of sealed penetrations within 48 hours after install

v. Exterior raceways are required to cover any exposed electrical components above rooflines and seal any roof membrane penetrations. Penetration sealing must be coordinated with Landlord’s roofing contractor to preserve roof warranty. Should roof penetrations need to be made for sign installations, Tenant must use Landlord's roofing contractor. No exceptions.

w. Interior raceways may be required to conceal wiring/transformers on interior of Tenant space if open ceiling condition exists, depending on sign location and conditions. Raceway must be painted to match wall. Field survey conditions.

x. LEDs are not to be visible on sign. All illumination to be even lighting without any hotspots on surfaces.

Perimeter Tenant Signage Type F/F1 32

Page 33: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Sign Type F - Single Line Text

Varies

TENANTTENANT TENANT

Sign Type F Examples - Single Line Text

TENANT

Signage mounting height will be determined at the time of installation by Landlord.

Perimeter Tenant Signage Type F/F1 EXHIBIT F.1 - Perimeter Sign Type F - Single Line Text 32

36” -

42”

max

hei

ght

33

Page 34: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

SIGN TYPE F Single Line Text

Variable Length

Plan View Fabricated aluminum reverse channel letter forms with halo illumination.

TENANT Elevation

2½” (min) to 4" (max)

Fabricated reverse aluminumchannel letter with .090 face /.063 return/ .1875 Lexan back

Brand specific LEDs on returnfor halo illumination

Aluminum cover over weephole to prevent light leak -(2) two - ¼” weep holesper letter

EIFS wall systemover concrete

1" to 1½”1½” to 2" standoff with aluminumspacers as required; Paint to matchbuilding surface.

Low voltage wire

³/16" clear Lexan backs withmechanically fastened to returnsw/ angle clips & C.S. screws

3/8" threaded stainless concretewedge anchor

U.L. Shut off switch &rubber boot in cabinetor as required foraccess

Secondary electrical source fromremote modular 60 power supply

Section

Note: All bolts, connectors, sleeves, electrical conduits, etc. to be non-ferrous. All penetrations thru wall panel to be watertight. Tenant Sign Contractor to provide a pin support from the top of the letter back to exterior wall with a minimum two (2)-inch penetration (Epoxy-anchored and sealed); Tenant Contractor shall not fully penetrate the parapet wall. Penetration to stop at Least 1 from the back side of wall.

36” - 42”

36” - 42”

EXHIBIT F.2 - Single Line Text Detail 33

Page 35: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Sign Type F1 - Double Line Text

Varies

Sign Type F1 Examples - Double Line Text

Signage mounting height will be determined at the time of installation by Landlord.

EXHIBIT F3 - Perimeter Sign Type F1 - Double Line Text 34

36” -

42”

max

as

sem

bly

Page 36: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

SIGN TYPE F1 Variable lengthDouble Line Text

2" to 4" max.

Plan View

24”/30" high fabricated aluminum, reverse channel letter forms with halo illumination

TENANT S E C O N D A R Y C O P Y

Optional secondary copy line on raceway routed from10" electrical raceway attached to wall

Elevation

2½” (min) to 4" (max)

Fabricated reverse aluminumchannel letter with .090 face/.063 return/.1875 Lexan back

Brand specific LEDs on returnfor halo illumination

Aluminum cover over weephole to prevent light leak -(2) two – ¼” weep holesper letter

EIFS wall systemover concrete

sign face with push-thru acrylic letters. Translucentacrylic with frosted finish on face or any color vinyl and½” reveal. Color by Tenant, approved by Landlord.

1" to 1½”1½” to 2" standoff with aluminumspacers as required; Paint to matchbuilding surface.

Low voltage wire

³/16" clear Lexan backs withmechanically fastened to returnsw/ angle clips & C.S. screws

⅜" threaded stainless concretewedge anchor

U.L. Shut off switch &rubber boot in cabinetor as required foraccess

Secondary electrical source fromremote modular 60 power supply

Section

Note: All bolts, connectors, sleeves, electrical conduits, etc. to be non-ferrous. All penetrations thru tilt-up concrete wall panel to bewatertight. LEDs are not to be visible on sign. All illumination to be even lighting without any hotspots on surfaces

EXHIBIT F4 - Perimeter Sign Type F1 - Details 35

36” -

42”

m

ax

asse

mbl

y

36” -

42”

max

as

sem

bly

Page 37: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Sign Type G/G1: TOWER SIGNAGE - FABRICATED ALUMINUM PUSH-THRU FACE LIT CHANNEL LETTERS OR FOR LOGOS ONLY: ROUTED ALUMINUM CABINET WITH PUSH-THRU ACRYLIC LETTERS/LOGO

a. All Tower signs (size, design, type and color) are subject to Landlord's approval. b. Square footage for Tenant wall signs shall be based on maximum sign lengths and

letter heights as defined in the following criteria and exhibits. c. Additional exterior wall signs shall be permitted to Tenants based on the Landlord's

discretion. d. Signs shall include letters and logos designating the store name as stated in signed

lease documents between Tenant and Landlord. e. No temporary signs are to be used. f. No projections outside of each designated sign area are allowed. g. Tenant logos may either be face lit logo or routed aluminum cabinet with push-thru

letters/logo. Colors to be approved by Landlord. h. All logos (size, design, type and color) are subject to Landlord's approval. i. Square footage for Tenant logos shall be based on maximum square footage allowed,

and consideration to maximum sign heights will occur on those sign areas that can accommodate larger logos, however they may not exceed or intrude upon any architectural sign fascia/projection.

j. Select Tenants in the project may be offered one or more such sign(s) at Landlord's discretion.

k. Logo/letter returns shall match the faces, or black. l. All signs shall fit within the architectural frame as indicated herein. m. All signs should establish a facade rhythm, scale and proportion where not currently

existing. n. The size of any sign logo shall be consistent with the proportions of scale of building

elements in the facade. o. Tenant signs shall be mounted as indicated in this criteria.p. Landlord will provide electrical power and conduit to Landlord provided J-box. If not

provided, Tenant shall be responsible to supply and install J-box and any required connections per Building Standard and Landlord specifications. Power provided to perimeter signs is 120 volt.

q. Perimeter signs shall be installed during non-business hours. r. Lighting: Lighting to be brand specific LEDs. The signs electrical components: power

supply, transformers are to be fully enclosed within a rectangular metal weather-proofed aluminum remote raceway.

s. Color of letters must show sufficient contrast to building fascia subject to Landlord's discretion and approval.

t. Bolts, connectors, sleeves, etc. shall be all non-ferrous materials. u. All penetrations thru walls to be watertight. v. Exterior raceways are required to cover any exposed electrical components above

rooflines and seal any roof membrane penetrations. Penetration sealing must be coordinated with Landlord’s roofing contractor to preserve roof warranty. Should roof penetrations need to be made for sign installations, Tenant must use Landlord's roofing contractor. No exceptions.

w. ALL penetrations must be sealed inside and out. Installer MUST email Landlord photos of front and back of sealed penetrations within 3 days after install of any tower sign.

x. Interior raceways may be required to conceal wiring/transformers on interior of Tenant space if open ceiling condition exists, depending on sign location and conditions. Raceway must be painted to match wall. Field survey conditions.

y. LEDs are not to be visible on sign. All illumination to be even lighting without any hotspots on surfaces.

Tenant Tower Signage - Sign Type G/G1 37

Page 38: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

SIGN TYPE G/G1

TENANT TENANT TENANT TENANT

Sign Type G/G1 Examples

Signage mounting height will be determined at the time of installation by Landlord.

Tenant Tower Signage - Sign Type G2 38

EXHIBIT G.1 - Tower Tenant Signage Elevation 37

Page 39: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Tenant Tower Signage - Sign Type G2 39

Page 40: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

SIGN TYPE G/G1 Tower Signage

Variable Length

Plan View

Elevation

2½” (min) to 4" (max)

1" - 1½” standoff with aluminumspacers as required; Paint to matchwall surface.

Fabricated aluminum channelletter with acrylic push-thruletter face

Brand specific LEDs to provide sufficient illumination

with no hot spots

Aluminum cover over weephole to prevent light leak -(2) two - ¼” weep holesper letter

Existing vertical2"x4 " member

Existing horizontal2"x6" member

Fabricated aluminum channelletter with acrylic push-thruletter face

6"x6"x¼” thick aluminum plate withwelded 1½”x1½”"x¼” wall x 5" longaluminum tube. Plate to be fastenedwith (2) ⅜" dia x 4" long lag screwsand 1" O.D. x .25" wall aluminumspacers to existing wood blocking

2"x8" wood blocking betweenmetal studs by others - fastenedwith (6) #10 x 3" long woodscrews

.090 aluminum letter backs

Low voltage wire

U.L. Shut off switch &rubber boot in cabinetor as required foraccess

Secondary electrical source fromremote power supply

EIFS wall system over ⅝" sheathing

6" metal stud framing, typ.

Section

EXHIBIT G/G1 - Typical Wall Section at Tower with Horizontal Members 38

Note: All bolts, connectors, sleeves, electrical conduits, etc. to be non-ferrous. LEDs are not to be visible on sign. All illumination to be even lighting without any hotspots on surfaces

Page 41: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Sign Type G2: LOGOS/LOGOS WITH TYPE: ALUMINUM FACE WITH PUSH-THRU ACRYLIC LETTERS. ILLUMINATION BY LEDS. LOGOS/LOGOS WITH TEXT ONLY.

a. Fabricated enclosed weatherproof aluminum box type cabinet with routed face and push-thru acrylic copy. Cabinet to be illuminated with brand specific LEDs to create sufficient illumination for sign location with no hot spots.

b. Any copy within the logo box cabinet shall be routed from aluminum logo face with push-thru acrylic letters/logo symbol. Copy/symbol shall be translucent acrylic with frosted finish on face or any color vinyl and ½” reveal. No glue-on allowed.

c. Size of logo will vary depending on elevation and designated sign band area. d. All perimeter signs (size, design, type and color) are subject to Landlord's

approval. Logos shall be contrast in color to wall.e. Additional exterior wall signs shall be permitted to Tenants based on the

Landlord's discretion.f. Signs shall include letters and logos designating the store name as stated in

signed lease documents between Tenant and Landlord.g. No temporary signs are to be used.h. No projections outside of each designated sign area are allowed.i. Tenant logos to be internally illuminated cabinets with routed face and push-

thru acrylic.j. Square footage for Tenant logos shall be based on maximum square footage

allowed, and consideration to maximum sign heights will occur on those sign areas that can accommodate larger logos, however they may not exceed or intrude upon any architectural sign fascia/projection.

k. Logo/letter returns shall match the faces.l. All signs shall fit within the architectural frame as indicated herein.m. All signs should establish a facade rhythm, scale and proportion where not

currently existing.n. The size of any sign logo shall be consistent with the proportions of scale of

building elements in the facade.o. Landlord will provide electrical power and conduit to Landlord provided J-box. If

not provided, Tenant shall be responsible to supply and install J-box and any required connections per Building Standard and Landlord specifications. Power provided to perimeter signs is 120 volt.

p. All penetrations must be watertight. ALL penetrations must be sealed inside and out. Installer MUST email Landlord photos of front and back of sealed penetrations within 48 hours after install.

q. Perimeter signs shall be installed during non-business hours. r. Color of cabinet/logo must show sufficient contrast to building fascia subject

to Landlord's discretion and approval. s. Bolts, connectors, sleeves, etc. shall be all non-ferrous materials.

Tenant Tower Signage - Sign Type G2 41

Page 42: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

SIGN TYPE G2

LOGO COPY

LOGO COPY

LOGO COPY

LOGO COPY

Tenant Tower Signage - Sign Type G2 42

…..

……

Page 43: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Sign Type G2 Examples

Signage mounting height will be determined at the time of installation by Landlord.

SIGN TYPE G2

2½” (min) to 6" (max)

1" - 1½” standoff with aluminum spacers as required; Paint to match wall surface.

Fabricated aluminum cabinetwith internal LED illuminationand ½” thick routed and push-thru acrylic logo copy.

Brand specific LEDs & low voltage wire

U.L. shut off switch & rubber

boot in cabinet or as requiredfor access

Aluminum cover over weephole to prevent light leak -(2) two – ¼” weep holesper letter

Existing horizontal2"x6" member

LOGOCOPY

Elevation

Tenant Tower Signage - Sign Type G2 43

EXHIBIT G2.2 - Tower Signage - Sign Type G2 - Details

Page 44: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Fabricated aluminum face lit sign with⅛" thick aluminum backing.Inside of the letter to be painted withMatte finish light enhancement paint.

Brand specific LEDs modules mounted to the aluminum backer panel.

Logo/Name made of push-thruacrylic letters with ½” reveal

6"x6"x¼” thick aluminum plate withwelded 1½”x1½”x¼” wall x 5" longaluminum tube. Plate to be fastenedwith (2) ⅜" dia x 4" long lag screwsand 1" O.D. x .25" wall aluminumspacers to existing wood blocking

2"x8" wood blocking betweenmetal studs by others - fastenedwith (6) #10 x 3" long woodscrews

.125" thick aluminum backs withmechanically fastened to returnsw/ angle clips & C.S. screws

EIFS wall system over ⅝" sheathing

Cabinet to have self contained powersupply when applicable, or remotepower supply as approved by Landlord.

Existing vertical 2"x4 " member

6" metal stud framing, typ.

Section

Tenant Tower Signage - Sign Type G2 44

Page 45: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Tower Sign Mounting Details 45

Page 46: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Tower Sign Mounting Details 46

Page 47: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Tower Sign Mounting Details 47

Page 48: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

SPECIFIC SIGNAGE CRITERIA 1. Service/Delivery Signage

The Landlord shall furnish and install suite number to be located on the rear door of Tenant’s suite. The sign shall be positioned on the door at a typical location in a material, size and color determined by Landlord.

2. Temporary Signage a. Temporary Promotional Signage on Exterior of Store.

i. No temporary promotional exterior store identification signage is allowed. ii. Exterior banners for promotional purposes are prohibited inside the store. iii. A-frame poster holder or other types of freestanding signs may not be

outside of the Lease Line at any time. The Lease Line is defined as the boundary between storefront glazing and entrance doors and common areas.

iv. No merchandise shall be placed outside of Lease Line. b. Temporary Promotional Signage Inside Store Only.

i. All temporary signage must be submitted to the General Manager for review and approval of Promotional Sign Variance.

ii. Each variance shall be limited to two (2) weeks, and upon expiration may be renewed once with proof of supporting advertising (4 week maximum).

iii. The total area of promotional signage is limited to one (1) square foot per lineal foot of store frontage.

iv. All temporary promotional signage must be professionally produced. Handmade or personal computer graphic signs are prohibited.

v. Promotional signs affixed in any manner to storefront windows or entry doors are prohibited. Such signs intended to be visible through storefront windows may be temporarily suspended with aircraft cable or monofilament no closer than twelve (12”) inches from the inside of window. The Landlord reserves the right to remove any promotional material that is visible through the storefront windows which is deemed to be inconsistent with the quality level of the Center.

vi. Fabric of lightweight posters must be weighted. Curled sign materials are not permitted.

vii. All interior banners shall be considered Temporary Promotional Signage and as such, be subject to all rules governing same. The area of interior banners may not exceed one (1) square foot per lineal foot of storefront. In no case may an interior banner be hung closer to the storefront than half the distance from the furthest back wall of the store, and may not be suspended with the lower edge less than eight (8') feet above the floor.

3. Prohibited Signs a. Signs constituting a traffic hazard - No persons shall install or cause to be

installed or maintain any sign which simulates or imitates in size, color, lettering, or design, any traffic sign or signal, or which makes use of the words Stop, Look, Danger or any other words, phases, symbols or characters in such a manner to interfere with, mislead or confuse traffic.

b. Immoral or Unlawful Advertising - It shall be unlawful for any person to exhibit, post or display, cause to be exhibited, posted or displayed upon any sign, anything of any obscene, indecent or immoral nature or unlawful activity.

c. No signs will be permitted in the common area in front of the store. No signs shall be installed, relocated or maintained so as to prevent free ingress to or egress from any door.

d. Animated, Audible or Moving Signs - Signs consisting of, or giving the effect of moving, swinging, rotating, flashing, blinking, scintillating, fluctuating or having animated light area are prohibited.

e. Off-Premise Signs - Any sign installed for the purpose of advertising a project, event, person or subject occurring off the Center property is prohibited unless approved in writing by the General Manager.

Specific Signage Criteria 48

Page 49: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

f. Vehicle Signs - Signs on or affixed to trucks, automobiles, trailers or other vehicles which advertise, identify or provide direction to a use or activity not related to its lawful making of deliveries of merchandise or service, are prohibited.

g. Light Bulb Strings and Exposed Tubing - Storefront display lighting (other than temporary, decorative holiday lighting) which consist of unshielded light bulbs, open, exposed neon or gaseous light tubing are prohibited. An exception hereto may be granted by Landlord with prior written approval when the display is an integral part of the design character of the activity to which it relates.

h. Credit Card/Telecheck/Security Signage - Vendor provided adhesive signs are prohibited on any entry doors or display windows.

i. Lettering painted directly on the building facade will not be permitted except as defined in these criteria.

j. Unprofessional hand-lettered signs are prohibited in the public view from the storefront. Absolutely no signs are permitted to be taped to the storefront on any visible surface.

k. Inventory Liquidation Signs - Going Out of Business, Bankruptcy Sale, Closing This Store, Lost Our Lease, etc. signs are strictly prohibited.

l. Flyers - Distribution of flyers, for any purpose, outside of Tenant's leased premises unless specifically authorized by Landlord is prohibited.

m. Neon or Internally Illuminated Signs - Unless specifically approved by the Landlord, neon or internally illuminated signage is prohibited inside stores.

4. Food Court Signage - Food Court Tenants Only a. General Sign Criteria

i. Square footage for the signs on designated facias within the Food Court area shall be based on the maximum sign lengths and letter heights as defined in this section.

ii. Colors to be approved by Landlord prior to fabrication and installation. If face lit letters are used, all letters must be trimless. Trim caps are not allowed.

iii. Tenant sign letters/logo are to be centered on the Tenant's sign band between Neutral Piers.

iv. Height: 48" max height for double line copy/30" max height for single line copy

v. Length: The length of the individual Tenant signs on sign panel shall not exceed eighteen feet (18'-0”) in sign length.

b. All Food Court Signs (size, design, color, material) are subject to Landlord's approval based on aesthetics and relationship to neighboring Tenant signs. Refer to Item B Submittals & Approvals under General Sign Criteria.

c. The information content on the signs shall be limited to letters designating the store name as set forth in signed lease documents between Tenant and Landlord.

d. No signage promoting brand name consumer goods will be accepted (i.e. Drink Coke, etc.). Soft drink company coolers are not permitted.

e. Tenants are encouraged to be creative with the designs of their signs. In addition to the established trade name of the store, icons or other graphic devices may be used to enhance the sign.

f. Tenant identification signs may be multi-layered. g. No projection above or below the designated sign zone will be permitted.

h. The center line of all copy and graphics shall be centered within the sign band as indicated on Food Court Tenant Signage Placement Exhibit.

i. All hardware is to be countersunk and painted to match. j. No photo transparency illuminated boxes are permitted for storefront sign.

Specific Signage Criteria 49

Page 50: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

k. Menu Boards. i. Sign boards displaying and prices shall be innovative and professionally

executed. ii. Proposed location and design of menu boards shall be included in Tenant's

signage submittal and are subject to the Landlord's Approval. iii. Permanent information shall be silk-screened, etched, painted or mounted

to a baseboard of metal, wood, plastic laminate, acrylic or glass. Flimsy or fragile materials are not permitted.

iv. Hand-written changeable information is not permitted. v. Internally illuminated menu boards are acceptable if they have a black face

with white (reversed) lettering. Design of this type of menu board is subject to Landlord approval.

vi. Chalkboards as use for menu boards are not permitted. vii. The following board types are strictly prohibited:

- Plastic, rubber or felt channel type boards with individual interchangeable plastic letters.

- Menu boards available through national food and beverage companies advertising products.

Specific Signage Criteria 50

Page 51: Chesterfield, Missouri - Do Business With Simon Property Group · Web viewStorefront Sign Type C 42 Tower Sign Mounting Details Elevation at Food Tenant Counter 48 3 General Signage

Enlarged Elevation

Elevation at Food Tenant Counter 51