10
Safe2Torch Checklist

Checklist - NFRC

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Checklist - NFRC

1

Safe2Torch Checklist

Page 2: Checklist - NFRC

2

Purpose of this document

The Safe2Torch visual checklist has been developed to help identify areas of risk before carrying out hot works. Use it to identify whether you have any of these types of work area present on the intended job and then apply the requirements in the Safe2Torch Safe System of Work (SSoW).

Page 3: Checklist - NFRC

3

Check the following fire risks before starting hot works

Exposed timber deck

Metal decking (refurbishment) where old material may accumulate in the troughs

Concrete substrate where expansion joints are exposed

Yes

No

N/A

Yes

No

N/A

Insulation unless specifically designed and tested for use with torch-on membranes

Yes

No

N/A

Yes

No

N/A

Page 4: Checklist - NFRC

4

Details

Expansion joints with voids and/or combustible fillers

Fibreboard or timber fillets

Details under all abutments to roof tiles and slates

Yes

No

N/A

Yes

No

N/A

Detail under cladding/rendering

Yes

No

N/A

Yes

No

N/A

Page 5: Checklist - NFRC

5

Details

All abutments with open cavities (open perpends)

All timber substrates

Change in level details with fixed timber

Yes

No

N/A

Yes

No

N/A

Plastic fascias, soffits or gutters

Yes

No

N/A

Yes

No

N/A

Page 6: Checklist - NFRC

6

Details

Restricted spaces

Window sills and frames and door sills

Louvered vents, air ducts, intakes and outtakes

Yes

No

N/A

Yes

No

N/A

Junctions to existing waterproofing with flammable insulation/deck materials

Yes

No

N/A

Yes

No

N/A

Page 7: Checklist - NFRC

7

Details

Vulnerable plastic curbs, domes, pipes and similar details

Working in close proximity to potentially flammable liquids, primers and coatings

Timber, DPC or sarking membranes beneath fixed metal capping systems

Yes

No

N/A

Yes

No

N/A

Existing kitchen extraction plant coated in oils or fats

Yes

No

N/A

Yes

No

N/A

Page 8: Checklist - NFRC

8

Details

Timber cladding

Flammable wrapping to trunking/ducting

Thatched roof

Yes

No

N/A

Yes

No

N/A

Yes

No

N/A

Page 9: Checklist - NFRC

9

Other concerns or fire risks

Page 10: Checklist - NFRC

For more information and to pledge your support

The National Federation of Roofing Contractors Ltd31 Worship Street London EC2A 2DY

T: 020 7638 7663 E: [email protected]

www.nfrc.co.uk/safe2torch

Version 1.0, June 2019