Charging of Accumulators for Alpha Lubricator

Embed Size (px)

DESCRIPTION

charging accumulators of Alfa lubricators

Citation preview

  • Page 2 (10) When referring to this page, please quote Procedure M90302 Edition 0226

    Cylinder Lubricators903-2.1Checking

    Check of Accumulators:

    4. Measuring the nitrogen pre-pressure canonly be done with stopped engine and pres-sure-free lubrication system.

    Stop both oil pumps. Close the inlet valveand open the equalizing valve on the re-spective lubricator.

    The nitrogen pressure in the inlet accumu-lator (0.7 litre) can be checked without dis-mounting the accumulator. For use of thepressure setting tool, see Step 5.

    5. To measure the nitrogen pressure in theoutlet accumulator (0.16 litre), the accumu-lator or the lubricator with accumulatormust be dismounted. See Procedure 903-2.2.

    For nitrogen pressure in the accumulators,see Data.

    6. Use of Pressure Setting ToolAssemble the pressure setting tool asshown in Figure 5, and mount the reducingvalve on the nitrogen cylinder. If necessary,use a threaded adaptor.

    Mount a 0-60 bar pressure gauge on the fill-ing valve when the inlet accumulator (0.7 li-tre) is to be checked, and a 0-10 barpressure gauge when the outlet accumula-tor (0.16 litre) is to be checked.

    3.

    EN90

    3-2.

    1 21

    9 04

    D-1D-2

    5.

    NA9

    03-2

    .1

    222

    05

  • When referring to this page, please quote Procedure M90302 Edition 0226 Page 3 (10)

    Cylinder Lubricators 903-2.1Checking

    7. Before mounting the filling valve on the ac-cumulator, check that the accumulator topis clean.

    Mount the filling valve on the relevant accu-mulator with the union nut. Check thatvalves C and F are closed.

    Loosen the plug screw in the accumulatorusing a square drive handle in socket E.

    It is now possible to read the actual nitro-gen pressure in the accumulator on the dialgauge on the filling valve.

    8. If the accumulator needs to be refilled withnitrogen, open valve A and increase theoutlet pressure from valve C on spindle Bto 1-2 bar above the pressure stated in Da-ta.

    Open valve C until the accumulator is filledto the correct pressure.

    Close valve C and tighten the plug screwwith socket E to the torque stated in Data.

    Release the pressure in the filling valve atbleed screw F.

    Unscrew the filling valve from the accumu-lator. Retighten the plug screw to the torquestated in Data. Remount the accumulator.

    6.

    NA9

    03-2

    .1 2

    22 0

    6

    A

    B

    C

    EFD-3

  • 103-2Cylinder LubricatorsDataSAFETY PRECAUTIONS

    Data

    Special Data0015S50MC-C Cylinder Lubricators103-2

    X Stopped engineX Block the starting mechanismX Shut off starting air supplyX Engage turning gear

    Shut off cooling waterShut off fuel oilShut off lubrication oilLock turbocharger rotors

    Ref. Description Value Unit

    D-1 Nitrogen pressure inlet accumulator 25-30 bar

    D-2 Nitrogen pressure outlet accumulator 1.5 bar

    D-3 Plug screw tightening torque 30 NmWhen referring to this page, please quote Data D10302 EMAN B&W Diesel A/S Standard Tools: See Section 913dition 0015 Page 1 (2)

  • Cylinder Lubricators103-2DataSpare Parts

    Plate Item No. Description Qty

    90307-xxx 102 O-ring 290307-xxx 234 O-ring 190307-xxx 246 Feedback sensor (pick-up), complete 190307-xxx 557 O-ring 190307-xxx 437 O-ring 1290307-xxx 582 O-ring 1Page 2 (2) When referring to this page, please quote Data D10302 Edition 0015MAN B&W Diesel A/S