Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
TR
1
2
" = 1' - 0"
1 2
LAYOUT &
PLANTING
L-1
TR
EXISTING
BUILDING
EXISTING ELECTRICAL
KEY
4" D. MED.-FINE
BARK MULCH
EXISTING
CONCRETE
3
L-2
CHARBONNEAU RESIDENCE
ENTRY GARDEN
5171 42ND AVENUE SOUTH | SEATTLE, WA 98118
OCTOBER 25, 2019
LIM
IT
O
F W
OR
K
LIMIT OF WORK
2' 0' 1' 2' 4' 8'
LAYOUT PLAN
2' 0' 1' 2' 4' 8'
PLANTING PLAN
1
2
3
PLANTS SCHEDULE
12'-0"
5"
5"
2'-0"
9'
6'-8"
17'
EXISTING
BUILDING
EXISTING
CONCRETE
PORCH
EXISTING
WALK
EXISTING
VENT WELL
EXISTING FENCE &
CONCRETE WALL
EXISTING
DOWNSPOUT, TYP.
EXISTING HOSE BIB
2'
2'
DRY "CREEK BED"
LAY OUT CHANNEL AND
PLACE LARGE ROCKS
APPROXIMATELY AS
SHOWN. NOTE: LEAVE
APPX. 2' X 2' AREA
AROUND HOSE BIB
CLEAR OF LARGE ROCKS
MEDIUM IGNEOUS
RIVER ROCK, MAX.
18" SIDE, TYP.
SMALL IGNEOUS RIVER ROCK, MAX. 8" SIDE, TYP.,
FILL CHANNEL AFTER PLACING LARGER ROCKS
NOTE: ENSURE NO ROCKS SMALLER THAN 2" DIA.
ARE INCLUDED
3
L-2
3
L-2
PAVING EDGE, TYP.
BEFORE MULCHING, EXCAVATE ALONG ALL WALK OR PATIO
EDGES TO ENSURE GRADE IS 4" BELOW FINISHED GRADE. TOP
SURFACE OF MULCH TO BE LEVEL WITH WALK OR PATIO.
4
L-2
PAVER PATIO,
2' X 2' CONCRETE PAVERS
FREESTANDING
CONCRETE PAVER
EXISTING
WALK
2
L-2
EXISTING DOGWOOD
EXISTING PLUM
1
L-2
4X4 PATIO EDGING
IF NEEDED, USE 4X8 (LAID ON END) ON
WEST SIDE IN PLACE OF 4X4 TO RETAIN
LEVEL PATIO AGAINST SLOPING GRADE
1
L-2
SL
OP
E A
PP
X. 8
" D
OW
N F
RO
M W
AL
K T
O B
UIL
DIN
G
LEAVE APPX. 2'
CLEARANCE BETWEEN
PLANTS AND WALL OR
ELECTRICAL EQUIPT.
LIM
IT
O
F W
OR
K
LIMIT OF WORK
SEE L-2/4, L-2/5 AND L-2/6
SEE L-2/4, L-2/5 AND L-2/6
ROOTBALL + 1'-0"MIN ALL SIDES
B&B OR CONTAINERIZED SHRUB (TYP)
SET ALL PLANTS AT NURSERY LEVEL (TYP)
MIN. 3" D. MULCH, SEE SPECS
SHRUB PLANTING PIT PREPARATION = ROOTBALL
DEPTH & WIDTH PLUS 1'-0" ADDITIONAL ALL SIDES
FINISHED GRADE
REMOVE ALL WIRE, STRING AND ALL BURLAP
FROM ROOTBALL. CLEAN ROOTBALL OF ALL
CONTAINER SOIL, TAKING CARE TO PREVENT
DAMAGE TO OR DRYING OF ROOTS. CAREFULLY
SPLAY OUT ROOTS AROUND ROOTBALL. BACKFILL
WITH 6" LAYERS OF WATER AND PLANTING SOIL,
WATERING IN EACH LAYER TO PREVENT
SUBSIDENCE.
ROOTBALL
DEPTH
℄
5'-0"MIN
1'-6"
STAKE TREE WITH (2) TREATED 2"Ø LODGEPOLE PINE DOWELED
TREE STAKES (8'-0" LENGTH)
"CHAINLOCK" OR EQUAL TREE TIE MATERIAL (1" WIDTH) NAIL
OR STAPLE TREE TIE MATERIAL TO STAKE TO HOLD
VERTICALLY. LOOP EACH TIE AROUND HALF TREE LOOSELY
TO PROVIDE 1" SLACK FOR TRUNK GROWTH
MIN. 4" PACIFIC TOPSOILS MEDIUM-FINE
BARK MULCH OR SIM. (TYP.)
(TAPERED AT TRUNK)
FINISHED GRADE
ROUGHEN SIDES OF PLANTING PIT
REMOVE ALL WIRE & STRING, AND REMOVE
ALL BURLAP FROM TOP 2/3 OF ROOTBALL
NATIVE BACKFILL SOIL AMENDMENT WITH 25% (@1/3
CU YD) DECOMPOSED ORGANIC MULCH AMENDMENT
FOR ENTIRE TREE PIT AREA X ROOTBALL DEPTH
UNDISTURBED SUBGRADE (PROVIDES FIRM
BASE SO THAT ROOTBALL WILL NOT SINK)
TREE PIT DEPTH=ROOTBALL DEPTH
(MEASURE BEFORE DIGGING TO
AVOID OVER-EXCAVATION)
SET TOP OF ROOT CROWN 2" ABOVE
ADJACENT GRADE
SHAPE SOIL SURFACE TO CREATE A
3' DIAMETER WATERING RING
DRIVE STAKES TO 1'-0" BELOW
ROOTBALL INTO UNDISTURBED SOIL
DRIVE STAKE AT ROOTBALL EDGE (TYP)
MIN WIDTH OF TREE PIT=2 TIMES
ROOTBALL DIAMETER OR 4'-0",
WHICHEVER IS GREATER
MULCH AREA TO BE CLEAR
OF GRASS, WEEDS, ETC. TO
REDUCE COMPETITION WITH
TREE ROOTS
℄
FOR
AREA
SPACING
ADJUSTMENT
CONTINUOUS OUTER ROW SETBACK
FROM EDGE OF PLANTING BED WITH
TRIANGULAR SPACING INSIDE BED, TYP.
FOR RECOMMENDED SPACING SEE PLANTING SCHEDULE
6" (TYP.)
EDGE OF PLANTING BED OR PAVEMENT
= PLANT LOCATION
WHEN PLANTING GROUNDCOVERS IN BEDS ALREADY PLANTED WITH
LARGER PLANTS, PLANT ONLY OUTER EDGES AND OPEN INTERIOR
SPACES, SPACING AS SHOWN ABOVE.
MIN. 4" PACIFIC TOPSOILS MEDIUM-FINE
BARK MULCH OR SIM. (TYP.)
SCARIFIED SUBGRADE
TYPICAL GROUND COVER PLANT
(PLANTED AT NURSERY LEVEL TYP.)
BEFORE MULCHING,
EXCAVATE ALONG ALL
WALK OR PATIO EDGES
TO ENSURE GRADE IS 4"
BELOW FINISHED GRADE.
TOP SURFACE OF MULCH
IS TO BE LEVEL WITH
WALK OR PATIO
12"
TR
2 2
DETAILS,
NOTES
L-2
TR
CHARBONNEAU RESIDENCE
ENTRY GARDEN
5171 42ND AVENUE SOUTH | SEATTLE, WA 98118
OCTOBER 25, 2019
PRECAST CONCRETE PAVER PATIO, 4X4 POST EDGING
SCALE: 1-
1
2
" = 1'-0"
12" L. #3 REBAR, 48" O.C., TYP.
4" D.
5
8
"-MINUS CRUSHED ROCK,
COMPACTED TO 90% DRY DENSITY,
LINED WITH GEOTEXTILE FABRIC
PRESSURE-TREATED
4 X 4 POST, TYP.
24" X 24" MUTUAL MATERIALS
VANCOUVER BAY GREY
PRECAST CONCRETE PAVER,
TYP.,
1
4
" JOINTS FILLED WITH
POLYMERIC FINISHING SAND
2" D. CLEAN PATIO/PAVER
SAND, COMPACTED TO
90% DRY DENSITY, LINED
WITH GEOTEXTILE FABRIC
1
24" X 24" MUTUAL MATERIALS VANCOUVER
BAY GREY PRECAST CONCRETE PAVER
4" D.
5
8
"-MINUS CRUSHED ROCK, COMPACTED
TO 90% DRY DENSITY, LINED WITH
GEOTEXTILE FABRIC
12" L. #3 REBAR, ROUGHLY CENTERED ON
EACH SIDE AND DRIVEN TIGHT TO EDGE,
SUNK 1" BELOW SURFACE OF PAVER, TYP.
FREESTANDING PRECAST CONCRETE PAVERS
SCALE: 1-
1
2
" = 1'-0"
2" D. CLEAN PATIO / PAVER SAND, LIGHTLY COMPACTED
AND LEVELLED, LINED WITH GEOTEXTILE FABRIC
2
SHRUB PLANTING
NOT TO SCALE
TREE PLANTING
NOT TO SCALE
GROUNDCOVER PLANT LAYOUT
NOT TO SCALE
BARK MULCH AND GROUNDCOVER PLANTING
NOT TO SCALE
7
5
4
8
DRY "CREEK BED"
3
SCALE: 1-
1
2
" = 1'-0"
SMALL IGNEOUS RIVER ROCK, MAX. 8" SIDE, TYP.,
FILL CHANNEL AFTER PLACING LARGER ROCKS
NOTE: ENSURE NO ROCKS SMALLER THAN 2" DIA.
ARE INCLUDED
MEDIUM IGNEOUS RIVER ROCK,
MAX. 18" SIDE, TYP.
PLACE AS SHOWN IN LAYOUT PLAN
4"
4" D. MEDIUM-FINE
BARK MULCH, TYP.
LINE CHANNEL WITH
LANDSCAPE FABRIC
(SMALL DASHES)
8"
SURROUNDING GRADE BEFORE
MULCHING (LARGE DASHES)
EXCAVATE 8" D. SLOPE-SIDED
CHANNEL, USE CUT TO CREATE
4" HT. SLOPED RIDGES ALONG
CHANNEL SIDES, TYP.
1'-0" - 3'-0"
LAY OUT AND MARK COURSE OF "CREEK" BEFORE DIGGING.
VARY CHANNEL WIDTH SMOOTHLY, AS SHOWN IN LAYOUT PLAN.
GROUNDCOVER PLANTING DIAGRAM
6
SCALE:
1
4
" = 1'-0"
KEY:
GROUNDCOVER PLANT
MIX FOR SHADE (SEE
PLANTS SCHEDULE)
GROUNDCOVER PLANT
MIX FOR SUN (SEE
PLANTS SCHEDULE)
EXISTING BUILDING
EXISTING
BUILDING
EXISTING
WALK
PLANTING AND MULCHING INSTRUCTIONS :
1. REMOVE ALL EXISTING PLANTS. RETAIN PLANTS FROM
SCHEDULE L-1/3 (Polystichum munitum, Fragaria chiloensis,
ETC.) IF DESIRED
2. CLEAR AND GRUB PLANTING BEDS OF ALL WEEDS,
DEAD PLANT MATERIAL, STUMPS, LARGE ROCKS, ETC.
3. DIG AWAY 4" MIN. DEPTH OF SOIL FROM ALL BUILDING
AND CONCRETE EDGES (APPX. 12" WIDE STRIP).
DEPOSIT REMOVED SOIL IN CENTER OF BED. THIS
PERMITS INSTALLATION OF 4" D. MULCH WITHOUT
SLUMPING ONTO WALKS.
4. GRADE BEDS SMOOTH AND EVENLY DISTRIBUTE
ALL-PURPOSE ORGANIC PLANT FOOD (APPX. 50 LBS.
FOR WHOLE SITE).
5. PLANT ALL TREES, SHRUBS AND PERENNIALS,
BREAKING UP ROOTBALLS TO SPREAD ROOTS OUT
LATERALLY. IMPORTANT: ROOT FLARE OF ALL PLANTS
TO BE 4" ABOVE SOIL GRADE , TO ALLOW FOR 4" D.
MULCH WITHOUT BURYING CROWNS OF PLANTS.
6. WATER IN PLANTS THOROUGHLY, THEN INSTALL 4" D.
WOODY MULCH (PACIFIC TOPSOILS MEDIUM-FINE BARK
MULCH OR SIM.). WATER AGAIN, AND GENTLY
COMPACT BY WALKING.
7. AFTER INSTALLING LARGER PLANTS AND MULCH, LAY
OUT AND PLANT GROUNDCOVER PLANTS (12" O.C.).
PUSH ASIDE MULCH FOR EACH PLANT, CREATE SMALL
HOLE IN SOIL, INSTALL PLANT AND RESTORE MULCH
AROUND EACH PLANT. WATER THOROUGHLY.
SEE PLANTING DETAILS L-2
EDGING:
PRESSURE-TREATED 4X4 POST
(OR SUB. 7 LF 4X8 POST, SEE LAYOUT PLAN NOTE)
#3 REBAR
PAVER PATIO AND FREESTANDING PAVER:
5
8
"-MINUS CRUSHED ROCK (OR
1
4
"-MINUS)
CLEAN PATIO/PAVER SAND
24" X 24" MUTUAL MATERIALS VANCOUVER BAY PRECAST CONCRETE PAVERS, GREY
LANDSCAPE FABRIC
FINISH:
PACIFIC TOPSOILS MEDIUM-FINE BARK MULCH OR SIM.
DRY "CREEK BED":
MEDIUM IGNEOUS RIVER ROCK, MAX. 18" SIDE
SMALL IGNEOUS RIVER ROCK, MAX. 8" SIDE
LANDSCAPE FABRICMATERIALS TAKEOFFS (BY TYPE)
0.5 CY
0.25 CY
10
55 SF
26 LF
8 LF
2.5 CY
15 - 20
APPX. 0.25 CY
20 SF