30
9 CHARACTERIZED CONTROL VALVES (CCV ) Equal percentage flow characteristic yields a linear heat output. C v values equal to globe valves of the same size requiring no additional system design. Valve bodies available with stainless steel trim or chrome plated brass trim depending upon application and cost involved. Higher close-off rating ensures shut off . 3-way assemblies can be piped for mixing or diverting applications. Applications The Characterized Control Valve (CCV) marks a true advancement in control valves. It combines the high close-off capabilities of a ball valve with a specialized disc that ensures an equal percentage ow characteristic. Since its release in 1999, over 5 million CCVs have been sold in hydronic systems. The CCV offers a comprehensive Cv range for various applications such as air handlers, heating and cooling coils, fan coil units, unit ventilators, and VAV re-heat coils.

CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

9 CHARACTERIZED CONTROL VALVES(CCV )

■ Equal percentage fl ow characteristic yields a linear heat output.

■ Cv values equal to globe valves of the same size requiring no

additional system design.

■ Valve bodies available with stainless steel trim or chrome plated

brass trim depending upon application and cost involved.

■ Higher close-off rating ensures shut off.

■ 3-way assemblies can be piped for mixing or diverting applications.

Applications

The Characterized Control Valve (CCV) marks a true advancement

in control valves. It combines the high close-off capabilities of a ball

valve with a specialized disc that ensures an equal percentage fl ow

characteristic. Since its release in 1999, over 5 million CCVs have

been sold in hydronic systems. The CCV offers a comprehensive Cv

range for various applications such as air handlers, heating and cooling

coils, fan coil units, unit ventilators, and VAV re-heat coils.

Page 2: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

Characterized Control Valve Nomenclature

Ordering Example

2

1 Choose the valve actuator combination.

+NO B209+LRX24-MFT +Tagging (if needed)

Specify preference or confi guration.

3

Set-Up

5 Complete Ordering Example: B209+LRX24-MFT+NO+A01

Does order

require

tagging?

Tagging:

Valves may be

tagged per customer

specifi cation. ($10.00

charge per tag)

Example:

AHU-1

FCU-2

Part number for

tagging: 99981-00101

4

For MFT Orders Only - Select Programming Code

P-10001 (A01)

P-100xx (Axx) Control voltage applications

P-200xx (Wxx) Pulse width modulation

applications

P-300xx (Fxx) Floating Point applications

P-400xx (Jxx) On/Off applications

X-XXXXX Create custom MFT

confi guration code

X-XXXXX Create custom MFT

confi guration in the fi eld

with MFT-actuator PC-Tool software

Non-Spring Models

NO = Normally Open

NC = Normally Closed

Spring Return Models

NO/FO = Normally Open/Fail Open

NO/FC = Normally Open/Fail Closed

NC/FO = Normally Closed/Fail Open

NC/FC = Normally Closed/Fail Closed

See settings

Refers to valve ports A to AB.

*LR and AR include 120-240 VAC

B2 09 LRX 24 -MFT

Valve

B2 = 2-way

B3 = 3-way

Valve Size

07-80 = ½” to 3”

Trim Material

B = Chrome Plated

Brass Ball,

Nickel Plated

Stem

Blank = Stainless

Steel Ball

and Stem

Actuator Type

Non-Spring Return

TR

LRB

LRX

NRB

NRX

ARB

ARX

Spring Return

TFR

LF

AFR

Electronic Fail-Safe

GKR

Power Supply

24 = 24 VAC/DC

120 = 120 VAC*

230 = 230 VAC

UP = 24 to 240 VAC

Control

Blank = On/Off, Floating

Point

-3 = Floating Point

-SR = 2-10 VDC

-MFT = Multi-Function

Technology

-MFT95 = 0-135 Ω

-S = Built-in

Auxiliary

Switch

-T = Terminal

Strip

N4 = NEMA

4/4X

N4H = NEMA

4/4X

with

Heater

Page 3: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

9-1

B6 Characterized Control Valve Nomenclature

Ordering Example

2

1 Choose the valve actuator combination.

+NO B6250S-070+GRX24-MFT +Tagging (if needed)

Specify preference or confi guration.

3

Set-Up

5 Complete Ordering Example: B6250S-070+GRX24-MFT+NO+A01

Does order

require

tagging?

Tagging:

Valves may be

tagged per customer

specifi cation. ($10.00

charge per tag)

Example:

AHU-1

FCU-2

Part number for

tagging: 99981-00101

4

For MFT Orders Only - Select Programming Code

P-10001 (A01)

P-100xx (Axx) Control voltage applications

P-200xx (Wxx) Pulse width modulation

applications

P-300xx (Fxx) Floating Point applications

P-400xx (Jxx) On/Off applications

X-XXXXX Create custom MFT

confi guration code

X-XXXXX Create custom MFT

confi guration in the fi eld

with MFT-actuator PC-Tool software

Non-Spring Models

NO = Normally Open

NC = Normally Closed

Spring Return Models

NO/FO = Normally Open/Fail Open

NO/FC = Normally Open/Fail Closed

NC/FO = Normally Closed/Fail Open

NC/FC = Normally Closed/Fail Closed

See settings

Refers to valve ports A to AB.

*AR includes 120-240 VAC

B6 250 S -070 GRX 24 -MFT

Valve

B6 = 2-way

Flanged

Valve Size

250 = 2½” to 6”

Trim Material

S = Stainless

Steel Ball and

Stem

Cv

070 = 70 Cv

110 = 110 Cv

186 = 186 Cv

290 = 290 Cv

400 = 400 Cv

Actuator Type

Non-Spring Return

AR

GR

Spring Return

AFR

Electronic Fail-Safe

GKR

Power Supply

24 = 24 VAC/DC

120 = 120 VAC*

230 = 230 VAC

UP = 24 to 240 VAC

Control

Blank = On/Off, Floating

Point

-3 = Floating Point

-SR = 2-10 VDC

-MFT = Multi-Function

Technology

-MFT95 = 0-135 Ω

Page 4: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

9-2

Equal PercentageCharacteristic

CCV

Mode of OperationThe Characterized Control Valve is operated by a rotary actuator. The actuators are controlled by a standard voltagefor on/off control, a proportional signal, or 3-point controlsystem which move the ball of the valve to the positiondictated by the control system.

Product FeaturesThe equal-percentage characteristic of the fl ow is ensuredby the integral characterizing disc. This characteristicprovides linear heating or cooling output from the coilimproving energy effi ciency and comfort.

Actuator Specifi cationsControl type on/off, fl oating point, 2-10 VDC, multi-function technology (MFT)Manual override TR, LR, AR, NR, AFR seriesElectrical connection 3 ft. [1 m] cable with ½” conduit fi tting or covered screw terminal strip

Valve Specifi cationsService chilled or hot water, 60% glycolFlow characteristic A-port equal percentage B-port modifi ed for constant common port fl owControllable fl ow range 75°Sizes ½” - 2”End fi tting NPT female endsMaterials Body forged brass, nickel plated Ball stainless steel or chrome plated Stem stainless steel or chrome plated Seats Tefl on® PTFE Seat o-rings EPDM Characterizing disc ½”- 1 ½” (2-way) Tefzel® ½”-1” (3-way) Tefzel® 2” (2-way) B248-B250 Tefzel® 2” (2-way) B251-B254 stainless steel 1¼”- 2” (3-way) stainless steel O-rings EPDM (lubricated)Media temp. range 0°F to 250°F [-18°C to +120°C]Body pressure rating ½” - 1¼” (2-way) 600 psi ½” - 1” (3-way) 600 psi 1¼”(B231) - 2”(B251) 400 psi 1¼” - 2” (3-way) 400 psiClose-off pressure 200 psiMaximum differential pressure (ΔP) 50 psiLeakage 0% for A to AB < 2.0% for B to ABCv rating B port: 70% of A to AB CvTefzel® and Tefl on® are registered trademarks of DuPont

Valve Nominal Size Type Suitable Actuators

Cv Inches DN [mm]

2-wayNPT

3-wayNPT

Non-SpringReturn

Spring Return

NEMA 4

NEMA4X

½ 15 B207(B) B307(B)

TR S

erie

s

LR S

erie

s

TFR

Serie

s

LF S

erie

s

NR S

erie

s

0.46 ½ 15 B208(B) B308(B)

0.8 ½ 15 B209(B) B309(B)

1.2 ½ 15 B210(B) B310(B)

1.9 ½ 15 B211(B) B311(B)

3 ½ 15 B212(B) B312(B)

4.7 ½ 15 B213(B) B313(B)

7.4 ½ 15 B214(B)

10 ½ 15 B215(B) B315(B)

16 ½ 15 B216(B)* B316(B)*

4.7 ¾ 20 B217(B) B317(B)

7.4 ¾ 20 B218(B) B318(B)

10 ¾ 20 B219(B)

14 ¾ 20 B220(B)*

14 ¾ 20 B320(B)

24 ¾ 20 B221(B)* B321(B)*

7.4 1 25 B222 B322

10 1 25 B223 B323

19 1 25 B224

30 1 25 B225* B325*

10 1¼ 32 B229

19 1¼ 32 B230*

10 1¼ 32 B329

AR S

erie

s

AFR

Serie

s

AFR

Serie

s

AR S

erie

s

19 1¼ 32 B330

25 1¼ 32 B231 B331

37 1¼ 40 B232*

19 1½ 40 B238 B338

29 1½ 40 B239 B339

37 1½ 40 B240* B340

46 1½ 40 B341

29 2 50 B248 B347

37 2 50 B348

46 2 50 B249 B349

57 2 50 B250* B350

65 2 50 B251

68 2 50 B351

83 2 50 B352

85 2 50 B252

120 2 50 B253

240 2 50 B254*

* Models without characterizing discs. (B) Models with chrome plated brass ball and brass stem

Characterized Control Valve Product RangeB2.., B3..

Control Valve Product Range

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 5: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

9-3

Equal PercentageCharacteristic

CCV

Mode of OperationThe Characterized Control Valve is operated by a rotary actuator. The actuators are controlled by a standard voltagefor on/off control, a proportional signal, or 3-point controlsystem which move the ball of the valve to the positiondictated by the control system.

Product FeaturesThe equal-percentage characteristic of the fl ow is ensuredby the integral characterizing disc. This characteristicprovides linear heating or cooling output from the coilimproving energy effi ciency and comfort.

Actuator Specifi cationsControl type on/off, fl oating point, 2-10 VDC, multi-function technology (MFT)Manual override AR and AFR seriesElectrical connection 3 ft. [1 m] cable with ½” conduit fi tting or covered screw terminal strip

Valve Specifi cationsService chilled or hot water, 60% glycolFlow characteristic A-port equal percentage B-port modifi ed for constant common port fl owControllable fl ow range 75°Sizes 2½” - 3”End fi tting NPT female endsMaterials Body forged brass, nickel plated Ball stainless steel Stem stainless steel Seats Tefl on® PTFE Seat o-rings EPDM Characterizing disc Tefzel® O-rings EPDM (lubricated)Media temp. range 0°F to 212°F [-18°C to +100°C]Body pressure rating 400 psiClose-off pressure 100 psiMaximum differential pressure (ΔP) 30 psiLeakage 0% for A to AB < 2.0% for B to ABTefzel® and Tefl on® are registered trademarks of DuPont

Valve Nominal Size Type Suitable Actuators

Cv Inches DN [mm] 2-wayNPT

Non-SpringReturn

Spring Return NEMA 4X

60 2½ 65 B261

AR S

erie

s

AFR

Serie

s

AR S

erie

s

75 2½ 65 B262

110 2½ 65 B263

150 2½ 65 B264

210 2½ 65 B265*

70 3 80 B277

130 3 80 B278

170 3 80 B280*

* Models without characterizing disc

Characterized Control Valve Product RangeB2..

Control Valve Product RangeP1

5001

- 04

/14

- Sub

ject

to c

hang

e. ©

Bel

imo

Airc

ontro

ls (U

SA),

Inc.

Page 6: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

9-4

Control Valve Product Range

Characterized Control Valve Product RangeB6..

Equal PercentageCharacteristic

CCV

Mode of OperationThe Characterized Control Valve is operated by a rotary actuator. The actuators are controlled by a standard voltage for on/off control, a proportional signal, or 3-point control system which move the ball of the valve to the position dictated by the control system.

Product FeaturesThe equal-percentage characteristic of the fl ow is ensured by the integral characterizing disc. This characteristic provides linear heating or cooling output from the coil improving energy effi ciency and comfort.

Actuator Specifi cationsControl type on/off, fl oating point, 2-10 VDC, multi-function technology (MFT)Manual override AR, GR, AFR and GKR seriesElectrical connection 3 ft. [1 m] cable with ½” conduit fi tting or covered screw terminal strip

Valve Specifi cationsService chilled or hot water, 60% glycolFlow characteristic A-port equal percentageControllable fl ow range 75°Sizes 2½”, 3”, 4”, 5”, 6”End fi tting ANSI 125 fl ange patternMaterials Body cast iron GG25 Ball stainless steel Stem stainless steel Seats Tefl on® PTFE Seat o-rings EPDM rubber Characterizing disc stainless steel O-rings EPDM (lubricated)Media temp. range 0°F to 250°F [-18°C to +120°C]Body pressure rating ANSI 125, Class B °F Psi -20° to +150° 200 200° 180 225° 180 250° 175Close-off pressure 100 psiMaximum differential pressure (ΔP) 50 psiLeakage 0% for A to AB

Valve Nominal Size Type Suitable Actuators

Cv Inches DN [mm]

2-way Flanged

Non-SpringReturn

Spring Return

Electronic Fail-Safe

70 2½ 65 B6250S-070

AR AFR

110 2½ 65 B6250S-110

110 3 80 B6300S-110

186 4 100 B6400S-186GR GK

R

290 5 125 B6500S-290

400 6 150 B6600S-400

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 7: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-5

CCV

PIPING REDUCTION CHART

Piping Reduction Factor (Fp) - Correction Factor for Valves

Values in chart are corrected Cv ratings for indicated pipe size.

VALVE SIZE LINE SIZEModel # Inches DN [mm] Cv Rating ½” ¾” 1” 1¼” 1½” 2” 2½” 3” 4” 5” 6”B216* ½ 15 16 16 8.7 7 - - - - - - - -B221* ¾ 20 24 - 24 19 16.1 14.6 - - - - - -B225* 1 25 30 - - 30 27.3 24.9 21.9 - - - - -B230* 1¼ 32 19 - - - 19 18.8 18.2 17.9 - - - -B232* 1¼ 32 37 - - - 37 35.5 31.8 30 - - - -B240* 1½ 40 37 - - - - 37 35 34 33 - - -B250* 2 50 57 - - - - - 57 56 54 52 - -B251 2 50 65 - - - - - 65 65 64 64 - -B252 2 50 85 - - - - - 85 81 78 74 - -B253 2 50 120 - - - - - 120 107 102 92 - -B254* 2 50 240 - - - - - 240 197 182 148 - -B261 2½ 65 60 - - - - - - 60 58 55 54 -B262 2½ 65 75 - - - - - - 75 73 72 70 -B263 2½ 65 110 - - - - - - 110 104 100 95 -B264 2½ 65 150 - - - - - - 150 139 132 122 -B265* 2½ 65 210 - - - - - - 210 190 175 164 -B277 3 80 70 - - - - - - - 70 69 68 68B278 3 80 130 - - - - - - - 130 119 115 113B280* 3 80 170 - - - - - - - 170 148 142 139

* Models without characterizing discs.

NOTE: Please use the corrected Cv values for the valves listed in the chart when installing them in pipes larger than the line size of the valve.All CCVs not listed do not require piping reduction factors.

NOTE: Values also apply to A-AB flow of 3-way versions.

Characterized Control ValvesP1

5001

- 04

/14

- Sub

ject

to c

hang

e. ©

Bel

imo

Airc

ontro

ls (U

SA),

Inc.

Page 8: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-6

CCV

SET-UP

2-WAY VALVE 3-WAY VALVESPECIFY UPON ORDERING SPECIFY UPON ORDERING

NON-

SPRI

NG R

ETUR

NSt

ays

in L

ast P

ositi

on

TR24-3(-T) Power to pin 2 will drive valve CCW. Power to pin 3will drive valve CW.

Power to pin 2 will drive valve CCW. Power to pin 3will drive valve CW.

LRB24-3(-T), ARB24-3(-T) Power to pin 2 will drive valve CW. Power to pin 3will drive valve CCW. Theabove will fuction when the directional switch is in the"1" position to reverse, selectthe "0" position.

Power to pin 2 will drive valve CW. Power to pin 3will drive valve CCW. Theabove will fuction when the directional switch is in the"1" position to reverse, selectthe "0" position.

TR24-SR(-T), LRB24-SR,LRB(X)24-MFT, ARB24-SR, ARB(X)24-MFT

NC: Normally closed A to AB, valve will open as voltage increases

NO: Normally open A to AB,valve will close as voltage increases

NC: Normally closed A to AB, valve will open as voltage increases

NO: Normally open A to AB,valve will close as voltage increases

SPRI

NG R

ETUR

NNo

te F

ail P

ositi

on

TFRB24, LF24 US, AFRB24

NO/FO: Normally open A toAB, valve will drive closed.Spring Action: Actuatorwill fail open A to AB uponpower loss.

NC/FC: Normally closed A to AB, valve will drive open. Spring Action: Actuator will fail closed A to AB uponpower loss.

NO/FO: Normally open A toAB, valve will drive closed.Spring Action: Actuatorwill fail open A to AB uponpower loss.

NC/FC: Normally closed A to AB, valve will drive open. Spring Action: Actuator will fail closed A to AB uponpower loss.

TFRB24-3, TFRB24-SR, TFRX24-MFT,LF24-3 US, LF24-SR US, LF24-MFT US, AFRB24-SR, AFRX24-MFT

NC/FO: Normally closed A to AB, valve will open as voltage increases. Actuatorswitch on CW. Spring Action: Will fail open upon power loss.

NC/FC: Normally closed A to AB, valve will open as voltage increases. Actuatorswitch on CW. Spring Action: Will fail closed upon power loss.

NO/FC: Normally open Ato AB, valve will close asvoltage increases. Actuatorswitch on CCW. Spring Action: Will fail closed upon power loss.

NO/FO: Normally open Ato AB, valve will close asvoltage increases. Actuatorswitch on CCW. Spring Action: Will fail open upon power loss.

Characterized Control ValvesEL

ECTR

ONIC

FAI

L-SA

FE

GKRB24-3-5-14† Power to pin 4 will drive valve CW. Power to pin 3will drive valve CCW. The above will fuction when the directional switch is in the"Y2" position to reverse, select the "Y1" position.

Power to pin 4 will drive valve CW. Power to pin 3will drive valve CCW. The above will fuction when the directional switch is in the"Y2" position to reverse, select the "Y1" position.

GKRX24-MFT-5-14† NC: Normally closed A to AB, will open as voltage increases when directionalswitch is in the “Y2” position.

NO: Normally open A toAB, will close as voltageincreases when directionalswitch is in the “Y1” position.

NC: Normally closed A to AB, will open as voltage increases when directionalswitch is in the “Y2” position.

NO: Normally open A toAB, will close as voltageincreases when directionalswitch is in the “Y2” position.

† The GK series Electronic Fail-Safe actuator will drive to a predetermined postion using the FO/FC dial on the actuator upon loss of power.

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 9: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-7

CCV

Characterized Control Valves

FLOW PATTERNS

2-way Characterized Control Valves™ (Belimo B2 Series)

Two-way valvesshould be installedwith the discupstream.

Flow direction

3-way Characterized Control Valves™ (Belimo B3 Series)MIXING DIVERTING

The A-port mustbe piped to the coilto maintain propercontrol.

INCORRECT PIPING

The A-port must be piped to the coil to maintain proper control.

WARNING! Do Not Pipe in this manner! Note Valve Porting! The A-port must be piped to the coil, not the B-port!Flow is not possible from A to B. If AB-port is not piped as the common port, the valve must be re-piped. It is good practice to install a balancing valve in the bypass line. These valves are intended for closed loop systems. Do not installin an open loop system or in an application that is open to atmospheric pressure.

OPERATION/INSTALLATION – CORRECT PIPING

2-way valves should be installed with the disc upstream. If installed with disc downstream, flow curve will be deeper. If installed “backwards” it is NOT necessary to remove and change. No damage or control problems will occur.3-WAY VALVES MUST BE PIPED CORRECTLY. They can be mixing or diverting. Mixing is the preferred piping arrangement.

The BELIMO Characterized Control Valve is a CONTROL valve, not a manual valve adapted for actuation. The control port is the A-port. It is similar to the globe valve in that the middle port is the B or bypass port. The common port AB is on the main opposite the A-port. These diagrams are for typical applications only. Consult engineering specification and drawings for particular circumstances.

REDUCED B-PORT FLOWNote: The B-port flow of the 3-way CCV is lower than that of the A-port. In most applications this is beneficial since the reduced flow compensates for the inexistentpressure drop across the coil in the bypass mode. Therefore, proper sizing is important to avoid flow noise in particular when the system is designed with constant speed pumps. Please refer to our valve sizing and selection guidelines.The flow velocity in the pipe upstream and downstream of the valve should be considered as well. The typical HVAC design maximum flow is 4 to 8 ft./s to avoid noise issues.Also, the pipe reduction factor must be considered. Pipe reducers decrease the Cv value of a valve and consequently increase the pressure drop across the valvecreating a situation that could lead to noise or a lower than designed flow.

AAB 100% AAB 0%

AAB 100% AAB 0%BAB 0% BAB 70%

ABA 100% ABA 0%ABB 0% ABB 70%

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 10: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-8

CCV

B2/B3 Series Characterized Control Valves with Non-Spring Return Actuators2-way and 3-way Valves with Chrome Plated Brass Ball and Brass Stem, NPT Female Ends

ACTUATOR PART # TR24-3-T US TR24-3 US TR24-SR-T US TR24-SR US LRB24-3 LRB24-SR

Control type On/Off,Floating Point

On/Off,Floating Point Proportional Proportional On/Off,

Floating Point Proportional

Manual override • • • • • •Running time 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds 90 secondsActuator noise level <35 dB(A) <35 dB(A) <35 dB(A) <35 dB(A) <35 dB(A) <35 dB(A)ELECTRICAL CONNECTION:½” conduit fi tting • •3 ft. cable • • • •Covered terminal strip • •

2-WAY

Model # Cv Rating

Valve Nominal Size Close-Off psiInches DN/mm

B207B 0.3 ½ 15 200 $183 $195 $274 $286 $254 $379B208B 0.46 ½ 15 200 $183 $195 $274 $286 $254 $379B209B 0.8 ½ 15 200 $183 $195 $274 $286 $254 $379B210B 1.2 ½ 15 200 $185 $197 $276 $288 $256 $381B211B 1.9 ½ 15 200 $185 $197 $276 $288 $256 $381B212B 3 ½ 15 200 $189 $201 $282 $294 $262 $390B213B 4.7 ½ 15 200 $191 $203 $286 $298 $264 $394B214B 7.4 ½ 15 200 $195 $207 $290 $305 $269 $402B215B 10 ½ 15 200 $197 $209 $292 $307 $271 $404B216B* 16 ½ 15 200 $199 $211 $294 $309 $274 $406B217B 4.7 ¾ 20 200 $235 $250 $310 $325 $305 $419B218B 7.4 ¾ 20 200 $238 $252 $315 $329 $308 $424B219B 10 ¾ 20 200 $240 $254 $317 $333 $310 $426B220B* 16 ¾ 20 200 $243 $256 $319 $335 $312 $428B221B* 24 ¾ 20 200 $316 $4323-WAYB307B 0.3 ½ 15 200 $223 $238 $341 $353 $295 $421B308B 0.46 ½ 15 200 $223 $238 $341 $353 $295 $421B309B 0.8 ½ 15 200 $223 $238 $341 $353 $295 $421B310B 1.2 ½ 15 200 $225 $240 $343 $355 $297 $424B311B 1.9 ½ 15 200 $225 $240 $343 $355 $297 $424B312B 3 ½ 15 200 $233 $248 $349 $361 $301 $431B313B 4.7 ½ 15 200 $235 $250 $353 $365 $305 $435B315B 10 ½ 15 200 $238 $252 $355 $367 $312 $437B316B* 16 ½ 15 200 $247 $261 $368 $380 $314 $439B317B 4.7 ¾ 20 200 $290 $305 $371 $388 $333 $459B318B 7.4 ¾ 20 200 $292 $307 $374 $390 $337 $461B320B 16 ¾ 20 200 $344 $463B321B* 24 ¾ 20 200 $347 $466

* Models without characterizing discs. For corrected Cvs with piping reduction factor refer to page 9-5.

Visit www.belimo.us to see additional non-spring return sactuator options including 120V and -S models.

Valve Specifi cationsService chilled or hot water,

60% glycolFlow characteristic A-port equal percentage

B-port modifi ed linear forconstant fl ow

Controllable fl ow range 75°End fi tting NPT female endsMaterials:

Body forged brass, nickel platedBall chrome plated brassStem nickel plated brassSeats Tefl on® PTFECharacterizing disc TEFZEL®

O-rings EPDM (lubricated)Media temp. range 0°F to 250°F

[-18°C to +120°C]Body pressure rating 600 psiMaximum differentialpressure (ΔP) 50 psiLeakage 0% for A to AB

<2.0% for B to ABCv rating A-port: as stated in chart

B-port: 70% of A to AB Cv

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 11: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-9

CCV

B2/B3 Series Characterized Control Valves with Spring Return Actuators2-way and 3-way Valves with Chrome Plated Brass Ball and Brass Stem, NPT Female Ends

ACTUATOR PART # TFRB24 TFRB24-3 TFRB24-SR LF24 US LF24-3 US LF24-SR USControl type On/Off Floating Point Proportional On/Off Floating Point Proportional

Running timeMotor <75 seconds 90 seconds 95 seconds 75 seconds 150 seconds 150 secondsSpring <75 seconds <25 seconds <25 seconds <25 seconds <25 seconds <25 seconds

Actuator noise levelRunning <40 dB(A) <35 dB(A) <35 dB(A) <50 dB(A) <30 dB(A) <30 dB(A)Spring <40 dB(A) <62 dB(A) <62 dB(A) <62 dB(A) <62 dB(A) <62 dB(A)

ELECTRICAL CONNECTION:3 ft. cable, ½” conduit fi tting • • • • • •

2-WAY

Model # Cv Rating

Valve Nominal Size Close-Off psiInches DN/mm

B207B 0.3 ½ 15 200 $355 $406 $435 $409 $519 $535B208B 0.46 ½ 15 200 $355 $406 $435 $409 $519 $535B209B 0.8 ½ 15 200 $355 $406 $435 $409 $519 $535B210B 1.2 ½ 15 200 $358 $409 $437 $411 $521 $537B211B 1.9 ½ 15 200 $358 $409 $437 $411 $521 $537B212B 3 ½ 15 200 $362 $411 $439 $417 $528 $543B213B 4.7 ½ 15 200 $364 $415 $446 $419 $530 $545B214B 7.4 ½ 15 200 $366 $417 $448 $421 $532 $547B215B 10 ½ 15 200 $368 $419 $450 $426 $537 $549B216B* 16 ½ 15 200 $370 $421 $452 $428 $539 $551B217B 4.7 ¾ 20 200 $409 $459 $493 $467 $579 $592B218B 7.4 ¾ 20 200 $411 $461 $495 $469 $581 $595B219B 10 ¾ 20 200 $413 $463 $497 $472 $583 $597B220B* 16 ¾ 20 200 $415 $469 $499 $474 $585 $599B221B* 24 ¾ 20 200 $476 $587 $6013-WAYB307B 0.3 ½ 15 200 $419 $491 $513 $485 $597 $617B308B 0.46 ½ 15 200 $419 $491 $513 $485 $597 $617B309B 0.8 ½ 15 200 $419 $491 $513 $485 $597 $617B310B 1.2 ½ 15 200 $421 $493 $517 $487 $599 $619B311B 1.9 ½ 15 200 $424 $495 $517 $487 $599 $619B312B 3 ½ 15 200 $428 $497 $519 $497 $610 $630B313B 4.7 ½ 15 200 $433 $501 $523 $499 $612 $632B315B 10 ½ 15 200 $435 $503 $526 $501 $614 $634B316B* 16 ½ 15 200 $437 $505 $528 $503 $616 $637B317B 4.7 ¾ 20 200 $469 $539 $562 $537 $650 $670B318B 7.4 ¾ 20 200 $472 $541 $564 $539 $653 $672B320B 16 ¾ 20 200 $543 $655 $677B321B* 24 ¾ 20 200 $546 $657 $680

* Models without characterizing discs. For corrected Cvs with piping reduction factor refer to page 9-5.

Valve Specifi cationschilled or hot water,60% glycol

Flow characteristic A-port equal percentageB-port modifi ed linear forconstant fl ow

Controllable fl ow range 75°End fi tting NPT female endsMaterials:

Body forged brass, nickel platedBall chrome plated brassStem nickel plated brassSeats Tefl on® PTFECharacterizing disc TEFZEL®

O-rings EPDM (lubricated)Media temp. range 0°F to 250°F

[-18°C to +120°C]Body pressure rating 600 psiMaximum differentialpressure (ΔP) 50 psiLeakage 0% for A to AB

<2.0% for B to ABCv rating A-port: as stated in chart

B-port: 70% of A to AB Cv

Visit www.belimo.us to see additional spring return sactuator options including 120V and -S models.

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 12: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-10

CCV

ACTUATOR PART # TR24-3-TUS

TR24-3US TR24-SR-T US TR24-SR

US LRB24-3 LRB24-SR LRX24-MFT

Control type On/Off,Floating Point

On/Off,Floating Point Proportional Proportional On/Off,

Floating Point Proportional Proportional/MFT

Manual override • • • • • • •

Running time 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds150 seconds

default / 35 to 200variable

Actuator noise level <35 dB(A) <35 dB(A) <35 dB(A) <35 dB(A) <35 dB(A) <35 dB(A) <35 dB(A)ELECTRICAL CONNECTION:½” conduit fi tting • • •3 ft. cable • • • • •Covered terminal strip • •

2-WAY

Model # Cv Rating

Valve Nominal Size Close-Off psiInches DN/mm

B207 0.3 ½ 15 200 $213 $231 $325 $339 $274 $381 $499B208 0.46 ½ 15 200 $213 $231 $325 $339 $274 $381 $499B209 0.8 ½ 15 200 $213 $231 $325 $339 $274 $381 $499B210 1.2 ½ 15 200 $219 $235 $327 $341 $276 $383 $503B211 1.9 ½ 15 200 $219 $235 $327 $341 $276 $383 $503B212 3 ½ 15 200 $223 $238 $329 $343 $278 $385 $508B213 4.7 ½ 15 200 $227 $243 $335 $347 $291 $390 $517B214 7.4 ½ 15 200 $233 $248 $339 $351 $297 $394 $521B215 10 ½ 15 200 $235 $250 $341 $353 $308 $402 $526B216* 16 ½ 15 200 $282 $294 $402 $414 $274 $406 $528B217 4.7 ¾ 20 200 $272 $284 $357 $369 $322 $411 $537B218 7.4 ¾ 20 200 $274 $286 $359 $371 $324 $413 $539B219 10 ¾ 20 200 $276 $288 $363 $379 $326 $415 $541B220* 16 ¾ 20 200 $278 $290 $365 $381 $348 $437 $576B221* 24 ¾ 20 200 $331 $420 $546B222 7.4 1 25 200 $339 $431 $573B223 10 1 25 200 $346 $433 $579B224 19 1 25 200 $346 $437 $588B225* 30 1 25 200 $388 $479 $617B229 10 1¼ 32 200 $385 $472 $612B230* 19 1¼ 32 200 $387 $476 $614

* Models without characterizing discs.For corrected Cvs with piping reduction factor refer to page 9-5.

Valve Specifi cationsService chilled or hot water,

60% glycolFlow characteristic A-port equal percentageControllable fl ow range 75°End fi tting NPT female endsMaterials:

Body forged brass, nickel platedBall stainless steelStem stainless steelSeats Tefl on® PTFECharacterizing disc TEFZEL®

O-rings EPDM (lubricated)Media temp. range 0°F to 250°F

[-18°C to +120°C]Body pressure rating 600 psi Maximum differentialpressure (ΔP) 50 psiLeakage 0% for A to AB

B2 Series Characterized Control Valves with Non-Spring Return Actuators2-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

Visit www.belimo.us for additional non-spring return sactuator options including 120V and -S models.

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 13: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-11

CCV

ACTUATOR PART # ARB24-3 ARB24-SR ARX24-MFTControl type On/Off, Floating Point Proportional Proportional/MFTManual override • • •Running time 90 seconds 90 seconds 150 sec. default / 90 to 300 variableActuator noise level <45 dB(A) <45 dB(A) <45 dB(A)ELECTRICAL CONNECTION:3 ft. cable, ½” conduit fi tting • • •

2-WAY

Model # Cv Rating

Valve Nominal Size Close-Off psiInches DN/mm

B231 25 1¼ 32 200 $448 $592 $644B232* 37 1¼ 32 200 $457 $597 $659B238 19 1½ 40 200 $457 $605 $659B239 29 1½ 40 200 $457 $607 $663B240* 37 1½ 40 200 $459 $610 $665B248 29 2 50 200 $592 $734 $784B249 46 2 50 200 $595 $741 $788B250* 57 2 50 200 $597 $745 $798B251 65 2 50 200 $862 $1,078B252 85 2 50 200 $934 $1,149B253 120 2 50 200 $1,003 $1,218B254* 240 2 50 200 $1,218 $1,439B261 60 2½ 65 100 $952 $1,167B262 75 2½ 65 100 $1,022 $1,237B263 110 2½ 65 100 $1,090 $1,309B264 150 2½ 65 100 $1,163 $1,363B265* 210 2½ 65 100 $1,307 $1,522B277 70 3 80 100 $1,176 $1,393B278 130 3 80 100 $1,245 $1,463B280* 170 3 80 100 $1,535 $1,753

* Models without characterizing discs. For corrected Cvs with piping reduction factor refer to page 9-5.

Valve Specifi cationsService chilled or hot water,

60% glycolFlow characteristic A-port equal percentageControllable fl ow range 75°End fi tting NPT female endsMaterials:

Body forged brass, nickel platedBall stainless steelStem stainless steelSeats Tefl on® PTFECharacterizing disc TEFZEL® or stainless steelO-rings EPDM (lubricated)

Media temp. range1¼”-2” 0°F to 250°F

[-18°C to +120°C]2½”-3” 0°F to 212°F

[-18°C to +100°C]Body pressure rating 400 psi Maximum differentialpressure (ΔP)

1¼”-2” 50 psi2½”-3” 30 psi

Leakage 0% for A to AB

B2 Series Characterized Control Valves with Non-Spring Return Actuators2-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

Visit www.belimo.us for additional non-spring return sactuator options including 120V and -S models.

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 14: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-12

CCV

Valve Specifi cationsService chilled or hot water,

60% glycolFlow characteristic A-port equal percentage

B-port modifi ed linear forconstant fl ow

Controllable fl ow range 75°End fi tting NPT female endsMaterials:

Body forged brass, nickel platedBall stainless steelStem stainless steelSeats Tefl on® PTFECharacterizing disc TEFZEL®

O-rings EPDM (lubricated)Media temp. range 0°F to 250°F

[-18°C to +120°C]Body pressure rating 600 psi Maximum differentialpressure (ΔP) 50 psiLeakage 0% for A to AB

<2.0% for B to ABCv rating B port: 70% of A to AB Cv

B3 Series Characterized Control Valves with Non-Spring Return Actuators3-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

ACTUATOR PART # TR24-3-T US TR24-3 US TR24-SR-T US TR24-SR US LRB24-3 LRB24-SR LRX24-MFT

Control type On/Off,Floating Point

On/Off,Floating Point Proportional Proportional On/Off,

Floating Point Proportional Proportional/MFT

Manual override • • • • • • •

Running time 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds 150 sec. default /35 to 200 variable

Actuator noise level <35 dB(A) <35 dB(A) <35 dB(A) <35 dB(A) <35 dB(A) <35 dB(A) <35 dB(A)ELECTRICAL CONNECTION:½” conduit fi tting • • •3 ft. cable • • • • •Covered terminal strip • •3-WAY

Model # Cv Rating

Valve Nominal Size Close-Off psiInches DN/mm

B307 0.3 ½ 15 200 $268 $280 $386 $398 $333 $453 $575B308 0.46 ½ 15 200 $268 $280 $386 $398 $333 $453 $575B309 0.8 ½ 15 200 $268 $280 $386 $398 $333 $453 $575B310 1.2 ½ 15 200 $270 $282 $388 $400 $335 $457 $577B311 1.9 ½ 15 200 $270 $282 $388 $400 $335 $457 $577B312 3 ½ 15 200 $276 $288 $394 $406 $344 $461 $579B313 4.7 ½ 15 200 $278 $290 $398 $410 $349 $467 $590B315 10 ½ 15 200 $280 $292 $400 $412 $355 $472 $592B316* 16 ½ 15 200 $289 $301 $412 $424 $358 $474 $595B317 4.7 ¾ 20 200 $335 $347 $448 $463 $415 $506 $614B318 7.4 ¾ 20 200 $339 $351 $450 $465 $417 $508 $617B320 16 ¾ 20 200 $424 $513 $619B321* 24 ¾ 20 200 $427 $516 $622B322 7.4 1 25 200 $448 $575 $706B323 10 1 25 200 $450 $577 $708B325* 30 1 25 200 $599 $583 $862

* Models without characterizing discs. For corrected Cvs with piping reduction factor refer to page 9-5.

Visit www.belimo.us for additional non-spring return sactuator options including 120V and -S models.

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 15: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-13

CCV

Valve Specifi cationsService chilled or hot water,

60% glycolFlow characteristic A-port equal percentage

B-port modifi ed linear forconstant fl ow

Controllable fl ow range 75°End fi tting NPT female endsMaterials:

Body forged brass, nickel platedBall stainless steelStem stainless steelSeats Tefl on® PTFECharacterizing disc stainless steelO-rings EPDM (lubricated)

Media temp. range 0°F to 250°F[-18°C to +120°C]

Body pressure rating 400 psi Maximum differentialpressure (ΔP) 50 psiLeakage 0% for A to AB

<2.0% for B to ABCv rating B port: 70% of A to AB Cv

B3 Series Characterized Control Valves with Non-Spring Return Actuators3-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

ACTUATOR PART # ARB24-3 ARB24-SR ARX24-MFT

Control type On/Off, Floating Point Proportional Proportional/MFTManual override • • •Running time 90 seconds 90 seconds 150 sec. default / 90 to 300 variableActuator noise level <45 db(A) <45 dB(A) <45 dB(A)ELECTRICAL CONNECTION:3 ft. cable, ½” conduit fi tting • • •

3-WAY

Model # Cv Rating

Valve Nominal Size Close-Off psiInches DN/mm

B329 10 1¼ 32 200 $523 $612 $723B330 19 1¼ 32 200 $528 $617 $732B331 25 1¼ 32 200 $665 $808 $862B338 19 1½ 40 200 $674 $823 $887B339 29 1½ 40 200 $677 $827 $890B340 37 1½ 40 200 $679 $831 $894B341 46 1½ 40 200 $683 $836 $898B347 29 2 50 200 $902 $1,030 $1,088B348 37 2 50 200 $905 $1,032 $1,090B349 46 2 50 200 $905 $1,036 $1,090B350 57 2 50 200 $911 $1,038 $1,092B351 68 2 50 200 $918 $1,047 $1,098B352 83 2 50 200 $926 $1,054 $1,104

For corrected Cvs with piping reduction factor refer to page 9-5.

Visit www.belimo.us for additional non-spring return sactuator options including 120V and -S models.

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 16: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-14

CCV

ACTUATOR PART # TFRB24 TFRB24-3 TFRB24-SR TFRX24-MFT LF24 US LF24-3 US LF24-SR US LF24-MFT US

Control type On/Off Floating Point Proportional Proportional/MFT On/Off Floating Point Proportional Proportional/

MFT

Running timeMotor <75 seconds 90 seconds 95 seconds

150 secondsdefault /

75 to 300variable

75 seconds 150 seconds 150 seconds150 secondsdefault / 75 to300 variable

Spring <75 seconds <25 seconds <25 seconds <25 seconds <25 seconds <25 seconds <25 seconds <25 seconds

Actuator noise levelRunning <40 dB(A) <35 dB(A) <35 dB(A) <35 dB(A) <50 dB(A) <30 dB(A) <30 dB(A) <30 dB(A)Spring <40 dB(A) <62 dB(A) <62 dB(A) <62 dB(A) <62 dB (A) <62 dB (A) <62 dB (A) <62 dB (A)

ELECTRICAL CONNECTION:3 ft. cable, ½” conduit fi tting • • • • • • • •

2-WAY

Model # Cv Rating

Valve Nominal Size Close-Off psiInches DN/mm

B207 0.3 ½ 15 200 $368 $419 $450 $530 $428 $537 $555 $641B208 0.46 ½ 15 200 $368 $419 $450 $530 $428 $537 $555 $641B209 0.8 ½ 15 200 $368 $419 $450 $530 $428 $537 $555 $641B210 1.2 ½ 15 200 $371 $424 $453 $532 $431 $539 $557 $646B211 1.9 ½ 15 200 $371 $424 $453 $532 $431 $539 $557 $646B212 3 ½ 15 200 $379 $428 $459 $537 $437 $545 $564 $655B213 4.7 ½ 15 200 $381 $431 $461 $539 $439 $547 $566 $661B214 7.4 ½ 15 200 $383 $433 $463 $541 $442 $549 $569 $672B215 10 ½ 15 200 $385 $435 $467 $543 $439 $551 $571 $679B216* 16 ½ 15 200 $387 $437 $469 $545 $428 $539 $551 $681B217 4.7 ¾ 20 200 $424 $474 $508 $573 $482 $592 $605 $691B218 7.4 ¾ 20 200 $426 $476 $510 $575 $485 $595 $607 $694B219 10 ¾ 20 200 $428 $479 $513 $577 $487 $597 $610 $696B220* 16 ¾ 20 200 $431 $487 $515 $579 $466 $558 $596 $724B221* 24 ¾ 20 200 $492 $602 $615 $702B222 7.4 1 25 200 $497 $603 $617 $714B223 10 1 25 200 $503 $612 $627 $716B224 19 1 25 200 $513 $619 $634 $719B225* 30 1 25 200 $534 $628 $662 $790B229 10 1¼ 32 200 $528 $646 $659 $741B230* 19 1¼ 32 200 $530 $650 $661 $743

* Models without characterizing discs. For corrected Cvs with piping reduction factor refer to page 9-5.

B2 Series Characterized Control Valves with Spring Return Actuators2-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

Valve Specifi cationsService chilled or hot water,

60% glycolFlow characteristic A-port equal percentageControllable fl ow range 75°End fi tting NPT female endsMaterials:

Body forged brass, nickel platedBall stainless steelStem stainless steelSeats Tefl on® PTFECharacterizing disc TEFZEL®

O-rings EPDM (lubricated)Media temp. range 0°F to 250°F

[-18°C to +120°C]Body pressure rating 600 psi Maximum differentialpressure (ΔP) 50 psiLeakage 0% for A to AB

Visit www.belimo.us for additional spring return sactuator options including 120V and -S models.

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 17: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-15

CCV

B2 Series Characterized Control Valves with Spring Return Actuators2-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

Valve Specifi cationsService chilled or hot water,

60% glycolFlow characteristic A-port equal percentageControllable fl ow range 75°End fi tting NPT female endsMaterials:

Body forged brass, nickel platedBall stainless steelStem stainless steelSeats Tefl on® PTFECharacterizing disc TEFZEL® or stainless steelO-rings EPDM (lubricated)

Media temp. range1¼”-2” 0°F to 250°F

[-18°C to +120°C]2½”-3” 0°F to 212°F

[-18°C to +100°C]Body pressure rating 400 psi Maximum differentialpressure (ΔP)

1¼”-2” 50 psi2½”-3” 30 psi

Leakage 0% for A to AB

ACTUATOR PART # AFRB24 AFRB24-SR AFRX24-MFT

Control type On/Off Proportional Proportional/MFTManual override • • •

Running timeMotor 75 seconds 90 seconds 150 seconds default /

70 to 200 variableSpring <20 seconds <20 seconds <20 seconds

Actuator noise levelRunning <50 dB(A) <40 dB(A) <45 dB(A)Spring <62 dB(A) <62 dB(A) <62 dB(A)

ELECTRICAL CONNECTION:3 ft. cable, ½” conduit fi tting • • •

2-WAY

Model # Cv Rating

Valve Nominal Size Close-Off psiInches DN/mm

B231 25 1¼ 32 200 $612 $759 $870B232* 37 1¼ 32 200 $614 $762 $872B238 19 1½ 40 200 $618 $768 $876B239 29 1½ 40 200 $620 $773 $878B240* 37 1½ 40 200 $622 $778 $880B248 29 2 50 200 $862 $1,035 $1,088B249 46 2 50 200 $872 $1,042 $1,096B250* 57 2 50 200 $880 $1,049 $1,100B251 65 2 50 200 $1,074 $1,218B252 85 2 50 200 $1,144 $1,293B253 120 2 50 200 $1,212 $1,361B254* 240 2 50 200 $1,216 $1,362B261 60 2½ 65 100 $1,219 $1,361B262 75 2½ 65 100 $1,275 $1,383B263 110 2½ 65 100 $1,340 $1,451B264 150 2½ 65 100 $1,371 $1,526B265* 210 2½ 65 100 $1,519 $1,667B277 70 3 80 100 $1,387 $1,540B278 130 3 80 100 $1,460 $1,606B280* 170 3 80 100 $1,745 $1,894

* Models without characterizing discs.For corrected Cvs with piping reduction factor refer to page 9-5.

Visit www.belimo.us for additional spring return sactuator options including 120V and -S models.

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 18: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-16

CCV

ACTUATOR PART # TFRB24 TFRB24-3 TFRB24-SR TFRX24-MFT LF24 US LF24-3 US LF24-SR US LF24-MFT US

Control type On/Off Floating Point Proportional Proportional/MFT On/Off Floating Point Proportional Proportional/

MFT

Running timeMotor <75 seconds 90 seconds 95 seconds

150 secondsdefault / 75 to300 variable

75 seconds 150 seconds 150 seconds150 secondsdefault / 75 to300 variable

Spring <75 seconds <25 seconds <25 seconds <25 seconds <25 seconds <25 seconds <25 seconds <25 seconds

Actuator noise levelRunning <40 dB(A) <35 dB(A) <35 dB(A) <35 dB(A) <50 dB(A) <30 dB(A) <30 dB(A) <30 dB(A)

Spring <40 dB(A) <62 dB(A) <62 dB(A) <62 dB(A) <62 dB (A) <62 dB (A) <62 dB (A) <62 dB (A)

ELECTRICAL CONNECTION:3 ft. cable, ½” conduit fi tting • • • • • • • •

3-WAY

Model # Cv Rating

Valve Nominal Size Close-Off psiInches DN/mm

B307 0.3 ½ 15 200 $444 $515 $526 $605 $501 $614 $646 $706B308 0.46 ½ 15 200 $444 $515 $526 $605 $501 $614 $646 $706B309 0.8 ½ 15 200 $444 $515 $526 $605 $501 $614 $646 $706B310 1.2 ½ 15 200 $446 $517 $528 $607 $503 $617 $648 $710B311 1.9 ½ 15 200 $450 $519 $530 $610 $503 $617 $648 $710B312 3 ½ 15 200 $457 $521 $535 $614 $515 $627 $659 $723B313 4.7 ½ 15 200 $459 $526 $539 $616 $517 $630 $661 $728B315 10 ½ 15 200 $461 $528 $541 $621 $519 $632 $665 $739B316* 16 ½ 15 200 $463 $530 $543 $623 $521 $634 $667 $741B317 4.7 ¾ 20 200 $501 $575 $583 $659 $549 $661 $683 $754B318 7.4 ¾ 20 200 $503 $577 $588 $663 $559 $667 $689 $759B320 14 ¾ 20 200 $566 $679 $701 $763B321* 24 ¾ 20 200 $546 $657 $680 $766B322 7.4 1 25 200 $583 $699 $714 $784B323 10 1 25 200 $590 $701 $716 $786B325* 30 1 25 200 $649 $775 $801 $964

*Models without characterizing discs.For corrected Cvs with piping reduction factor refer to page 9-5.

B3 Series Characterized Control Valves with Spring Return Actuators3-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

Valve Specifi cationsService chilled or hot water,

60% glycolFlow characteristic A port equal percentage

B port modifi ed linear forconstant fl ow

Controllable fl ow range 75°End fi tting NPT female endsMaterials:

Body forged brass, nickel platedBall stainless steelStem stainless steelSeats Tefl on® PTFECharacterizing disc TEFZEL® or stainless steelO-rings EPDM (lubricated)

Media temp. range 0°F to 250°F[-18°C to +120°C]

Body pressure rating 600 psi Maximum differentialpressure (ΔP) 50 psiLeakage 0% for A to AB

<2.0% for B to ABCv rating A-port: as stated in chart

B-port: 70% of A to AB Cv

Visit www.belimo.us for additional spring return sactuator options including 120V and -S models.

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 19: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-17

CCV

ACTUATOR PART # AFRB24 AFRB24-SR AFRX24-MFT

Control type On/Off Proportional Proportional/MFTManual override • • •

Running timeMotor 75 seconds 90 seconds 150 seconds default / 75 to 200 variableSpring <20 seconds <20 seconds <20 seconds

Actuator noise levelRunning <45 dB(A) <45 dB(A) <45 dB(A)Spring <62 dB(A) <62 dB(A) <62 dB(A)

ELECTRICAL CONNECTION:3 ft. cable, ½ ” conduit fi tting • • •

3-WAY

Model # Cv Rating

Valve Nominal Size Close-Off psiInches DN/mm

B329 10 1¼ 32 200 $697 $834 $868B330 19 1¼ 32 200 $703 $838 $872B331 25 1¼ 32 200 $850 $1,007 $1,078B338 19 1½ 40 200 $864 $1,022 $1,081B339 29 1½ 40 200 $866 $1,042 $1,083B340 37 1½ 40 200 $872 $1,048 $1,085B341 46 1½ 40 200 $1,039 $1,228 $1,264B347 29 2 50 200 $1,225 $1,393 $1,432B348 37 2 50 200 $1,228 $1,395 $1,435B349 46 2 50 200 $1,230 $1,397 $1,437B350 57 2 50 200 $1,235 $1,408 $1,442B351 68 2 50 200 $1,410 $1,629 $1,667B352 83 2 50 200 $1,472 $1,688 $1,727For corrected Cvs with piping reduction factor refer to page 9-5.

B3 Series Characterized Control Valve with Spring Return Actuators3-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

Valve Specifi cationsService chilled or hot water,

60% glycolFlow characteristic A port equal percentage

B port modifi ed linear forconstant fl ow

Controllable fl ow range 75°End fi tting NPT female endsMaterials:

Body forged brass, nickel platedBall stainless steelStem stainless steelSeats Tefl on® PTFECharacterizing disc stainless steelO-rings EPDM (lubricated)

Media temp. range 0°F to 250°F[-18°C to +120°C]

Body pressure rating 400 psi Maximum differentialpressure (ΔP) 50 psiLeakage 0% for A to AB

<2.0% for B to ABCv rating A-port: as stated in chart

B-port: 70% of A to AB Cv

Visit www.belimo.us for additional spring return sactuator options including 120V and -S models.

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 20: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-18

CCV

ACTUATOR PART # ARB24-3-5-14 ARX24-MFT-5-14 GRB24-3-5-14 GRX24-MFT-5-14On/Off, Floating Point Proportional/MFT On/Off, Floating Point Proportional/MFT

Manual override • • • •

Running time 90 seconds 150 seconds default / 90 to 150 variable 150 seconds 150 seconds

Actuator noise level <45 dB(A) <45 dB(A) <45 dB(A) <45 dB(A)ELECTRICAL CONNECTION:3 ft. cable, ½” conduit fi tting • • • •

2-WAY

Model # Cv Rating

Valve Nominal Size Close-Off

psiInches DN/mm

B6250S-070 70 2½ 65 100 $1,770 $1,932B6250S-110 110 2½ 65 100 $1,848 $1,994B6300S-110 110 3 80 100 $1,937 $2,165B6400S-186 186 4 100 100 $2,240 $2,403B6500S-290 290 5 125 100 $3,248 $3,334B6600S-400 400 6 150 100 $4,124 $4,213

Example: ARX24-MFT is the basic model. Add the P… pre-set MFT confi guration number and list price to the actuator when ordering, as needed.Note: Most popular confi gurations available at no additional cost. All other confi gurations carry a $34.00 list price.

B6 Series Characterized Control Valves with Non-Spring Return Actuators2-way Valve with Stainless Steel Ball and Stem, Flanged Ends

Valve Specifi cationsService chilled or hot water,

60% glycolFlow characteristic A-port equal percentageControllable fl ow range 75°End fi tting ANSI 125 fl ange patternMaterials:

Body cast iron - GG25Ball stainless steelStem stainless steelSeats Tefl on® PTFECharacterizing disc stainless steelO-rings EPDM (lubricated)

Media temp. range 0°F to 250°F[-18°C to +120°C]

Body pressure rating According to ANSI 125,standard class B

Maximum differentialpressure (ΔP)

50 psi

Leakage 0% for A to AB

Visit www.belimo.us for additional non-spring return sactuator options including 120V and -S models.

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 21: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-19

CCV

ACTUATOR PART # AFRB24-5-14 AFRX24-MFT-5-14 GKRX24-3-5-14 GKRX24-MFT-5-14Control type On/Off Proportional/MFT On/Off, Floating Point Proportional/MFTManual override • • • •

Running timeMotor 75 seconds 150 seconds default /

70 to 220 variable150 seconds default /

90 to 150 variable150 seconds default /

90 to 150 variableFail-Safe <20 seconds <20 seconds 35 seconds 35 seconds

Actuator noise levelRunning <45 dB(A) <45 dB(A) <45 dB(A) <45 dB(A)Spring 62 dB(A) 62 dB(A)

ELECTRICAL CONNECTION:3 ft. cable, ½” conduit fi tting • • • •

2-WAY

Model # Cv Rating

Valve Nominal Size Close-Off

psiInches DN/mm

B6250S-070 70 2½ 65 100 $1,804 $2,030B6250S-110 110 2½ 65 100 $1,886 $2,104B6300S-110 110 3 80 100 $2,036 $2,318B6400S-186 186 4 100 100 $2,524 $2,706B6500S-290 290 5 125 100 $3,542 $3,729B6600S-400 400 6 150 100 $4,404 $4,607

Example: AFRX24-MFT is the basic model. Add the P… pre-set MFT confi guration number and list price to the actuator when ordering, as needed.Note: Most popular confi gurations available at no additional cost. All other confi gurations carry a $34.00 list price.

B6 Series Characterized Control Valves with Spring Return and Electronic Fail-Safe Actuators

2-way Valve with Stainless Steel Ball and Stem, Flanged Ends

Valve Specifi cationschilled or hot water,60% glycol

Flow characteristic A-port equal percentageControllable fl ow range 75°End fi tting ANSI 125 fl ange patternMaterials:

Body cast iron - GG25Ball stainless steelStem stainless steelSeats Tefl on® PTFECharacterizing disc stainless steelO-rings EPDM (lubricated)

Media temp. range 0°F to 250°F[-18°C to +120°C]

Body pressure rating According to ANSI 125,standard class B

Maximum differentialpressure (ΔP)

50 psi

Leakage 0% for A to AB

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 22: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-20

CCV

ACTUATOR PART # NRX24-3-T N4 NRX24-SR-T N4 NRX24-MFT-T N4 ARX24-3-T N4 ARX24-SR-T N4 ARX24-MFT-T N4Control type On/Off, Floating Point Proportional Proportional/MFT On/Off, Floating Point Proportional Proportional/MFTManual override • • • • • •

Running time 90 seconds 90 seconds 150 seconds default / 60 to 200 variable 90 seconds 90 seconds 150 seconds default /

60 to 200 variableActuator noise level <45 dB(A) <45 dB(A) <45 dB(A) <45 dB(A) <45 dB(A) <45 dB(A)Optional built-in heater • • • • • •ELECTRICAL CONNECTION:Terminal strip • • • • • •

2-WAY

Model # Cv Rating

Valve Nominal Size Close-Off psiInches DN/mm

B207 0.3 ½ 15 200 $573 $679 $798B208 0.46 ½ 15 200 $573 $679 $798B209 0.8 ½ 15 200 $573 $679 $798B210 1.2 ½ 15 200 $575 $681 $803B211 1.9 ½ 15 200 $575 $681 $803B212 3 ½ 15 200 $575 $681 $803B213 4.7 ½ 15 200 $579 $687 $808B214 7.4 ½ 15 200 $585 $694 $814B215 10 ½ 15 200 $590 $699 $818B216* 16 ½ 15 200 $590 $698 $817B217 4.7 ¾ 20 200 $623 $712 $838B218 7.4 ¾ 20 200 $625 $714 $841B219 10 ¾ 20 200 $627 $716 $843B220* 16 ¾ 20 200 $632 $721 $847B221* 24 ¾ 20 200 $636 $724 $850B222 7.4 1 25 200 $641 $732 $872B223 10 1 25 200 $646 $734 $878B224 19 1 25 200 $646 $739 $885B225* 30 1 25 200 $650 $743 $890B229 10 1¼ 32 200 $685 $769 $911B230* 19 1¼ 32 200 $687 $773 $913B231 25 1¼ 32 200 $747 $887 $940B232* 37 1¼ 32 200 $749 $890 $946B238 19 1½ 40 200 $756 $902 $960B239 29 1½ 40 200 $756 $902 $960B240* 37 1½ 40 200 $761 $907 $950B248 29 2 50 200 $782 $909 $967B249 46 2 50 200 $890 $1,034 $1,085B250* 57 2 50 200 $892 $1,038 $1,090B251 65 2 50 200 $894 $1,047 $1,098B252 85 2 50 200 $1,163 $1,311 $1,378B253 120 2 50 200 $1,231 $1,383 $1,448B254* 240 2 50 200 $1,305 $1,453 $1,520B261 60 2½ 65 100 $1,317 $1,467 $1,535B262 75 2½ 65 100 $1,319 $1,469 $1,538B263 110 2½ 65 100 $1,321 $1,471 $1,540B264 150 2½ 65 100 $1,391 $1,540 $1,608B265* 210 2½ 65 100 $1,460 $1,610 $1,665B277 70 3 80 100 $1,475 $1,627 $1,690B278 130 3 80 100 $1,547 $1,694 $1,764B280* 170 3 80 100 $1,606 $1,757 $1,821

B2 Series Characterized Control Valves with NEMA 4X Non-Spring Return Actuators2-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

Valve Specifi cationsService chilled or hot water, 60% glycolFlow characteristic A-port equal percentageControllable fl ow range 75°End fi tting NPT female endsMaterials:

Body forged brass, nickel platedBall stainless steelStem stainless steelSeats Tefl on® PTFECharacterizing disc TEFZEL® or stainless steelO-rings EPDM (lubricated)

Media temp. range1½”-2”2½”-3”

0°F to 250°F [-18°C to +120°C] 0°F to 212°F [-18°C to +100°C]

Body pressure rating½” - 1¼” (B230) 600 psi 1¼” (B231) - 3” 400 psi

Maximum differentialpressure (ΔP) 50 psi (1½”-2”)

30 psi (2½”-3”)Leakage 0% for A to AB

ACTUATOR PART # NRX24-3-T N4H NRX24-SR-T N4H NRX24-MFT-T N4H ARX24-3-T N4H ARX24-SR-T N4H ARX24-MFT-T N4HAdd to List Price for heater +$365 +$365 +$365 +$365 +$365 +$365

*Models without characterizing discs. For corrected Cvs with piping reduction factor refer to page 9-5.

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 23: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-21

CCV

ACTUATOR PART # NRX24-3-T N4 NRX24-SR-T N4 NRX24-MFT-T N4 ARX24-3-T N4 ARX24-SR-T N4 ARX24-MFT-T N4Control type On/Off, Floating Point Proportional Proportional/MFT On/Off, Floating Point Proportional Proportional/MFTManual override • • • • • •

Running time 90 seconds 90 seconds 150 seconds default / 60 to 200 variable 90 seconds 90 seconds 150 seconds default /

60 to 200 variableActuator noise level <45 dB(A) <45 dB(A) <45 dB(A) <45 dB(A) <45 dB(A) <45 dB(A)Optional built-in heater • • • • • •ELECTRICAL CONNECTION:Terminal strip • • • • • •

3-WAY

Model # Cv Rating

Valve Nominal Size Close-Off psiInches DN/mm

B307 0.3 ½ 15 200 $619 $741 $874B308 0.46 ½ 15 200 $619 $741 $874B309 0.8 ½ 15 200 $619 $741 $874B310 1.2 ½ 15 200 $621 $743 $876B311 1.9 ½ 15 200 $621 $743 $876B312 3 ½ 15 200 $623 $745 $878B313 4.7 ½ 15 200 $623 $745 $878B315 10 ½ 15 200 $625 $747 $880B316* 16 ½ 15 200 $624 $746 $878B317 4.7 ¾ 20 200 $704 $790 $1,092B318 7.4 ¾ 20 200 $706 $792 $1,094B320 14 ¾ 20 200 $710 $796 $1,098B321* 24 ¾ 20 200 $713 $800 $1,101B322 7.4 1 25 200 $726 $849 $989B323 10 1 25 200 $728 $864 $1,006B325* 30 1 25 200 $737 $862 $1,003B329 10 1¼ 32 200 $825 $911 $1,022B330 19 1¼ 32 200 $829 $916 $1,032B331 25 1¼ 32 200 $967 $1,107 $1,163B338 19 1½ 40 200 $976 $1,120 $1,189B339 29 1½ 40 200 $978 $1,124 $1,191B340 37 1½ 40 200 $980 $1,126 $1,193B341 46 1½ 40 200 $982 $1,136 $1,200B347 29 2 50 200 $1,204 $1,329 $1,387B348 37 2 50 200 $1,206 $1,331 $1,391B349 46 2 50 200 $1,208 $1,338 $1,393B350 57 2 50 200 $1,213 $1,342 $1,399B351 68 2 50 200 $1,218 $1,344 $1,399B352 83 2 50 200 $1,223 $1,348 $1,403

B3 Series Characterized Control Valves with NEMA 4X Non-Spring Return Actuators3-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

Valve Specifi cationsService chilled or hot water,

60% glycolFlow characteristic A-port equal percentage

B-port modifi ed linear forconstant fl ow

Controllable fl ow range 75°End fi tting NPT female endsMaterials:

Body forged brass, nickel platedBall stainless steelStem stainless steelSeats Tefl on® PTFECharacterizing disc TEFZEL® or stainless steelO-rings EPDM (lubricated)

Media temp. range 0°F to 250°F[-18°C to +120°C]

Body pressure rating ½” - 1”1¼” - 2”

600 psi400 psi

Maximum differentialpressure (ΔP) 50 psiLeakage 0% for A to AB

<2.0% for B to ABCv rating B-port: 70% of A to AB Cv

ACTUATOR PART # NRX24-3-T N4H NRX24-SR-T N4H NRX24-MFT-T N4H ARX24-3-T N4H ARX24-SR-T N4H ARX24-MFT-T N4HAdd to List Price for heater +$365 +$365 +$365 +$365 +$365 +$365

*Models without characterizing discs. For corrected Cvs with piping reduction factor refer to page 9-5.

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 24: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-22

CCV

B2, B3 Series Characterized Control Valves with NEMA 4 Spring Return Actuators2-way and 3-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

Valve Specifi cationsService chilled or hot water, 60% glycolFlow characteristic A-port equal percentageControllable fl ow range 75°End fi tting NPT female endsMaterials:

Body forged brass, nickel platedBall stainless steelStem stainless steelSeats Tefl on® PTFECharacterizing disc TEFZEL® or stainless steelO-rings EPDM (lubricated)

Media temp. range1½”-2”2½”-3”

0°F to 250°F [-18°C to +120°C]0°F to 212°F [-18°C to +100°C]

Body pressure rating 400 psi Maximum differentialpressure (ΔP) 50 psi (1½”-2”)

30 psi (2½”-3”)Leakage 0% for A to ABCv rating A-port: as stated in chart

B-port: 70% of A to AB Cv

*Models without characterizing discs. For corrected Cvs with piping reduction factor refer to page 9-5.

ACTUATOR PART # AFRX24 N4H AFRX24-MFT N4H

Add to List Price for heater +$1,022 +$1,022

ACTUATOR PART # AFRX24 N4 AFRX24-MFT N4Control type On/Off, Floating Point Proportional/MFTManual override • •Running time 75 seconds 150 secondsActuator noise level <45 dB(A) <45 dB(A)Optional built-in heater • •ELECTRICAL CONNECTION:Terminal strip • •

2-WAY

Model # Cv Rating

Valve Nominal Size Close-Off psiInches DN/mm

B231 25 1¼ 32 200 $1,181 $1,356B232* 37 1¼ 32 200 $1,184 $1,360B238 19 1½ 40 200 $1,188 $1,364B239 29 1½ 40 200 $1,190 $1,366B240* 37 1½ 40 200 $1,193 $1,368B248 29 2 50 200 $1,432 $1,442B249 46 2 50 200 $1,442 $1,618B250* 57 2 50 200 $1,451 $1,626B251 65 2 50 200 $1,642 $1,820B252 85 2 50 200 $1,714 $1,889B253 120 2 50 200 $1,783 $1,957B254* 240 2 50 200 $1,999 $2,173B261 60 2½ 65 100 $1,732 $1,907B262 75 2½ 65 100 $1,802 $1,977B263 110 2½ 65 100 $1,874 $2,048B264 150 2½ 65 100 $1,941 $2,117B265* 210 2½ 65 100 $2,090 $2,264B277 70 3 80 100 $1,957 $2,132B278 130 3 80 100 $2,031 $2,205B280* 170 3 80 100 $2,314 $2,4903-WAYB329 10 1¼ 32 200 $1,369 $1,539B330 19 1¼ 32 200 $1,375 $1,543B331 25 1¼ 32 200 $1,521 $1,748B338 19 1½ 40 200 $1,535 $1,751B339 29 1½ 40 200 $1,537 $1,753B340 37 1½ 40 200 $1,543 $1,755B341 46 1½ 40 200 $1,710 $1,983B347 29 2 50 200 $1,894 $2,100B348 37 2 50 200 $1,897 $2,103B349 46 2 50 200 $1,899 $2,105B350 57 2 50 200 $1,905 $2,110B351 68 2 50 200 $2,079 $2,334B352 83 2 50 200 $2,140 $2,394

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 25: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-23

CCV

ACTUATOR PART # LRQX24-MFT NRQX24-MFT ARQX24-MFTControl type Proportional/MFT Proportional/MFT Proportional/MFTManual override • • •Running time 5 seconds (default) 5 seconds (default) 7 secondsActuator noise level <35 dB(A) <45 dB(A) <45 dB(A)ELECTRICAL CONNECTION:3 ft. cable, ½” conduit fi tting • • •2-WAY

Model # Cv Rating

Valve Nominal Size Close-Off psiInches DN/mm

B207 0.3 ½ 15 200 $661B208 0.46 ½ 15 200 $661B209 0.8 ½ 15 200 $661B210 1.2 ½ 15 200 $665B211 1.9 ½ 15 200 $665B212 3 ½ 15 200 $670B213 4.7 ½ 15 200 $679B214 7.4 ½ 15 200 $685B215 10 ½ 15 200 $689B216* 16 ½ 15 200 $691B217 4.7 ¾ 20 200 $704B218 7.4 ¾ 20 200 $706B219 10 ¾ 20 200 $708B220* 16 ¾ 20 200 $710B221* 24 ¾ 20 200 $713B222 7.4 1 25 200 $737B223 10 1 25 200 $743B224 19 1 25 200 $749B225* 30 1 25 200 $752B229 10 1¼ 32 200 $773B230* 19 1¼ 32 200 $776B231 25 1¼ 32 200 $808B232* 37 1¼ 32 200 $825B238 19 1½ 40 200 $825B239 29 1½ 40 200 $829B240* 37 1½ 40 200 $831B248 29 2 50 200 $950B249 46 2 50 200 $954B250* 57 2 50 200 $962B251 65 2 50 200 $1,215B252 85 2 50 200 $1,287B253 120 2 50 200 $1,353B254* 240 2 50 200 $1,548

* Models without characterizing discs. For corrected Cvs with piping reduction factor refer to page 9-5.

B2 Series Characterized Control Valveswith Quick Running Non-Spring Return Actuators

2-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

Valve Specifi cationsService chilled or hot water,

60% glycolFlow characteristic A-port equal percentageControllable fl ow range 75°End fi tting NPT female endsMaterials:

Body forged brass, nickel platedBall stainless steelStem stainless steelSeats Tefl on® PTFECharacterizing disc TEFZEL® or stainless steelO-rings EPDM (lubricated)

Media temp. range 0°F to 250°F[-18°C to +120°C]

Body pressure rating ½” - 1¼” (B230) 600 psi1¼” (B231) - 2” 400 psi

Maximum differentialpressure (ΔP) 50 psiLeakage 0% for A to AB

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 26: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-24

CCV

B3 Series Characterized Control Valveswith Quick Running Non-Spring Return Actuators3-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

ACTUATOR PART # LRQX24-MFT NRQX24-MFTControl type Proportional/MFT Proportional/MFTManual override • •Running time 5 seconds (default) 5 seconds (default)Actuator noise level <35 dB(A) <45 dB(A)ELECTRICAL CONNECTION:3 ft. cable, ½” conduit fi tting • •3-WAY

Model # Cv Rating

Valve Nominal Size Close-Off psiInches DN/mm

B307 0.3 ½ 15 200 $739B308 0.46 ½ 15 200 $739B309 0.8 ½ 15 200 $739B310 1.2 ½ 15 200 $741B311 1.9 ½ 15 200 $741B312 3 ½ 15 200 $743B313 4.7 ½ 15 200 $752B315 10 ½ 15 200 $754B316* 16 ½ 15 200 $753B317 4.7 ¾ 20 200 $776B318 7.4 ¾ 20 200 $780B320 14 ¾ 20 200 $782B321* 24 ¾ 20 200 $782B322 7.4 1 25 200 $868B323 10 1 25 200 $870B325* 30 1 25 200 $874B329 10 1¼ 32 200 $885

* Models without characterizing discs. For corrected Cvs with piping reduction factor refer to page 9-5.

Valve Specifi cationsService chilled or hot water,

60% glycolFlow characteristic A-port equal percentage

B port modifi ed linear forconstant fl ow

Controllable fl ow range 75°End fi tting NPT female endsMaterials:

Body forged brass, nickel platedBall stainless steelStem stainless steelSeats Tefl on® PTFECharacterizing disc TEFZEL® or stainless steelO-rings EPDM (lubricated)

Media temp. range 0°F to 250°F[-18°C to +120°C]

Body pressure rating: 600 psi Maximum differentialpressure (ΔP) 50 psiLeakage 0% for A to AB

<2.0% for B to ABCv rating B-port: 70% of A to AB Cv

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 27: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-25

CCV

Model Control Input Feedback PowerSupply

Running Time(s) VA Rating Cable

Length Re-order Number List Price

ARX24-3 On/Off, Floating Pointg Add on 24 VAC/VDC 95 5.5 10 ft. AR000 0C3 000 $392ARX24-3 On/Off, Floating Pointg Add on 24 VAC/VDC 95 5.5 16 ft. AR000 0C5 000 $413ARX24-3-S On/Off, Floating Pointg Built-in 24 VAC/VDC 95 5.5 10 ft. AR020 0A3 000 $492ARX24-3-S On/Off, Floating Pointg Built-in 24 VAC/VDC 95 5.5 16 ft. AR020 0A5 000 $514ARX24-3-T On/Off, Floating Pointg Add on 24 VAC/VDC 95 5.5 N/A ART00 0T2 000 $347ARX120-3 On/Off, Floating Pointg Add on 100-230 VAC/VDC 95 7 10 ft. AR060 0A3 000 $445ARX120-3 On/Off, Floating Pointg Add on 100-230 VAC/VDC 95 7 16.ft. AR060 0A5 000 $466ARX24-SR 2-10 VDC (4-20mA*)( ) 2-10 VDC 24 VAC/VDC 95 5 10 ft. AR030 0C3 000 $539ARX24-SR 2-10 VDC (4-20mA*)( ) 2-10 VDC 24 VAC/VDC 95 5 16 ft. AR030 0C5 000 $561ARX24-SR-T 2-10 VDC (4-20mA*)( ) 2-10 VDC 24 VAC/VDC 95 5 N/A ARTW0 0T2 000 $497ARX120-SR 2-10 VDC (4-20mA*)( ) 2-10 VDC 100-230 VAC/VDC 95 7.5 10 ft. AR450 0A3 000 $599ARX120-SR 2-10 VDC (4-20mA*)( ) 2-10 VDC 100-230 VAC/VDC 95 7.5 16 ft. AR4500A5 000 $621

MFT VERSIONSARX24-MFT Various Various 24 VAC/VDC Various 6 3 ft. AR100 0C1 XXX** $534ARX24-MFT Various Various 24 VAC/VDC Various 6 10 ft. AR100 0C3 XXX** $565ARX24-MFT Various Various 24 VAC/VDC Various 6 16 ft. AR100 0C5 XXX** $588ARX24-MFT95 0 to 135 Ω Various 24 VAC/VDC 150 6 3 ft. AR0L0 0C3 R01 $547

*With 500 Ω resistor** See page 9-27 for P-Codes available.The P-Code programs the actuator for the desired Control Input, Feedback and Running Time.

Actuator Specifi cationsTorque 180 in-lbs [20 Nm]Ambient temperature -22°F to +122°F

[-30°C to +50°C]Angle of rotation max 90°, adjustable

with mechanical stopelectronically variable

Position indication handleManual override external push-buttonDirection of rotation reversible with switchDimensions 7.47” x 3.45” x 2.52”

[189.8 x 88 x 64 mm]Electrical connection 18 GA plenum rated cable,

½” conduit connectorOverload protection electronic throughout

rotationAuxiliary switch(es) (-S) models: 1 SPDT, 3A

(0.5A inductive) @ 250Vadjustable 5° to 85°

Housing NEMA 2/IP54Agency listings cULus acc. to UL 60730-

1A/-2-14, CAN/CSA E60730-1:02, CSA C22.2 No. 24-93,CE acc. to 2006/95/EC and89/336/EEC

Variable with MFT

AR Series Non-Spring Return ActuatorsCustom, Direct Coupled, Non-Spring Return Actuator, 180 in-lbs Minimum Torque

All ARActuatorshave BDCM

MFT= 2-10 VDC Default, or Set, Modify, Read:• Control (PWM, VDC range, Floating Point)• Feedback (0-10 VDC, 0-5 VDC, 2-10 VDC, Variable)• Motion (run time)

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 28: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-26

CCV

LR Series Non-Spring Return ActuatorsCustom, Direct Coupled Non-Spring Return Actuator, 45 in-lbs Minimum Torque

Model Control Input Feedback Power SupplyRunningTime(s)[Default]

VARating

CableLength

Re-orderNumber List Price ‡

LRX24-3 On/Off, Floating Point Add on 24 VAC/DC 90 seconds 2 10 ft. LR000 RC3 000 $241LRX24-3 On/Off, Floating Point Add on 24 VAC/DC 90 seconds 2 16 ft. LR000 RC5 000 $262LRX24-3-S On/Off, Floating Point Add on 24 VAC/DC 90 seconds 2 10 ft. LR020 RA3 000 $330LRX24-3-S On/Off, Floating Point Add on 24 VAC/DC 90 seconds 2 16 ft. LR020 RA5 000 $352LRX24-3-T On/Off, Floating Point Add on 24 VAC/DC 90 seconds 2 N/A LRT00 RT2 000 $194LRX120-3 On/Off, Floating Point Add on 100-230 VAC 90 seconds 4 10 ft. LR060 RA3 000 $288LRX120-3 On/Off, Floating Point Add on 100-230 VAC 90 seconds 4 16 ft. LR060 RA5 000 $310LRX24-SR 2-10 VDC (4-20mA*) 2-10 VDC 24 VAC/DC 90 seconds 4.5 10 ft. LR030RC3 000 $359LRX24-SR 2-10 VDC (4-20mA*) 2-10 VDC 24 VAC/DC 90 seconds 4.5 16 ft. LR560RC5 000 $379LRX24-SR-T 2-10 VDC (4-20mA*) 2-10 VDC 24 VAC/DC 90 seconds 4.5 N/A LRTW0 5T2 000 $306LRX120-SR 2-10 VDC (4-20mA*) 2-10 VDC 100-230 VAC 90 seconds 4.5 10 ft. LR450 5A3 000 $430LRX120-SR 2-10 VDC (4-20mA*) 2-10 VDC 100-230 VAC 90 seconds 4.5 16 ft. LR450 5A5 000 $453

MFT VERSIONSLRX24-MFT Various Various 24 VAC/VDC Various 5 3 ft. LR100 RC1 XXX** $401LRX24-MFT Various Various 24 VAC/VDC Various 5 10 ft. LR100 RC3 XXX** $431LRX24-MFT Various Various 24 VAC/VDC Various 5 16 ft. LR100 RC5 XXX** $453LRX24-MFT95 0 to 135 Ω 2-10 VDC 24 VAC/VDC 150 seconds 5 3 ft. LR0L0 RC1 R01 $463

‡ Prices do not refl ect additional programming code surcharge.*With 500 Ω resistor** See page 9-27 for P-Codes available.The P-Code programs the actuator for the desired Control Input, Feedback and Running Time.

Actuator Specifi cationsTorque 45 in-lbs [5 Nm]Ambient temperature -22°F to +122°F

[-30°C to +50°C]Angle of rotation max. 90°, adjustable with

mechanical stopelectronically variable

Position indication handleManual override external push-buttonDirection of rotation reversible with switchDimensions 6.18” x 2.6” x 2.34”

[157 x 66 x 59.4 mm]Electrical connection 18 GA plenum rated cable,

½” conduit fi tting terminalstrip (-T) models

Overload protection electronic throughoutrotation

Auxiliary switch LRX24-3-S - 1SPDT, 3A(0.5A) @ 250 VAC, ULListed, adjustable 0° to 100°

Housing NEMA 2/IP54Agency listings cULus acc. to UL 60730-

1A/-2-14, CAN/CSA E60730-1:02, CSA C22.2 No. 24-93,CE acc. to 2006/95/EC and89/336/EEC

Variable with MFT

All actuatorshave BDCM

MFT= 2-10 VDC Default, or Set, Modify, Read:• Control (PWM, VDC range, Floating Point)• Feedback (0-10 VDC, 0-5 VDC, 2-10 VDC, Variable)• Motion (run time)

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 29: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-27

CCV

CONTROL

ACTUATOR TYPE CONFIGURATIONDESCRIPTION P-CODE CONTROL INPUT FEEDBACK POSITION RUNNING TIME List Price ‡

-3 and SR N/A 0 2-10 VDC (for -3) 2-10 VDC (for -3) 150 seconds No ChargeN/A 2 2-10 VDC (for -SR) 2-10 VDC (for -SR) 90 seconds No Charge

MFT and PC P-10001 A01 2-10 VDC 2-10 VDC 150 seconds No Charge*P-10002 A02 0.5-10 VDC 0-10 VDC 150 seconds No ChargeP-10003 A03 2-10 VDC 0-5.0 VDC 150 seconds No ChargeP-10004 A04 4-7 VDC 2-10 VDC 150 seconds $34P-10005 A05 6-9 VDC 2-10 VDC 150 seconds $34P-10006 A06 10.5 -13.5 VDC 2-10 VDC 150 seconds $34P-10007 A07 0.5-5 VDC 2-10 VDC 150 seconds $34P-10009 A09 5-10 VDC 2-10 VDC 150 seconds $34P-10010 A10 5-10 VDC 0-10 VDC 150 seconds $34P-10013 A13 0.5-10 VDC 2-10 VDC 150 seconds $34P-10015 A15 2-5 VDC 2-10 VDC 150 seconds $34P-10016 A16 2-6 VDC 2-10 VDC 150 seconds $34P-10017 A17 6-10 VDC 2-10 VDC 150 seconds $34P-10018 A18 14-17 VDC 2-10 VDC 150 seconds $34P-10020 A20 9-12 VDC 2-10 VDC 150 seconds $34P-10028 A28 0.5-10 VDC 0.5-10 VDC 100 seconds No ChargeP-10031 A31 0.5- 4 VDC 2-10 VDC 150 seconds $34P-10063 A63 0.5-4.5 VDC 0.5- 4.5 VDC 150 seconds No ChargeP-10032 A32 2-10 VDC 2-10 VDC 100 seconds No ChargeP-10064 A64 5.5-10 VDC 5.5-10.0 VDC 150 seconds No Charge

N/A AAT 2-10 VDC 2-10 VDC 20 seconds No ChargeP-20001 W01 0.59-2.93 seconds 2-10 VDC 150 seconds $34P-20002 W02 0.02 to 5.00 seconds 2-10 VDC 150 seconds No ChargeP-20003 W03 0.10 to 25.50 seconds 2-10 VDC 150 seconds No ChargeP-20004 W04 0.10 to 25.60 seconds 2-10 VDC 150 seconds $34P-20005 W05 0.10 to 5.20 seconds 0-5.0 VDC 150 seconds $34P-30001 F01 Floating Point 2-10 VDC 150 seconds No ChargeP-30002 F02 Floating Point 0-10 VDC 150 seconds $34P-40002 J02 On/Off 2-10 VDC 150 seconds No Charge

N/A S01 (for -PC only) Phasecut 2-10 VDC 150 seconds No ChargeP-16001 R01 (for -MFT95 only) 0 to 135 Ω 2-10 VDC 150 seconds No Charge

NOTE: More P-codes are available, consult factory.‡ Add to list price on previous page.*P-10001 is the default confi guration for MFT.

Customize ProductsDefault and MFT Programming Codes

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.

Page 30: CHARACTERIZED CONTROL VALVES (CCV )hvac.duralitte.com.mx/wp-content/uploads/2014/05/...Cv values equal to globe valves of the same size requiring no additional system design. Valve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-28

CCV

NON-SPRING RETURN SPRING RETURNWEATHER SHIELDS LR AR LF AF AFR List Price

ZS-CCV-90*CCV/PICCV weather shield kit LF/AF • • $215

ZS-CCV-100*CCV/PICCV weather shield kit LR/AR • • $215

ZS-CCV-110*CCV/PICCV weather shield kit AFR • $215

EXTENSION BRACKETCCV-EXT-KITCCV/PICCV valve neck extension kit forM5 screw

• • • • • $193

CCV-EXT-M4Linkage extension kit • • • • • $193

AUXILIARY SWITCHES & POTENTIOMETERSS1AAuxiliary switch - 1x SPDT, 3A(0.5A inductive) @ 250 VAC

• • $86

S2AAuxiliary switch - 2x SPDT, 3A(0.5A inductive) @ 250 VAC

• • $128

P140A GRFeedback potentiometer 140 Ω • • $141

P500A GRFeedback potentiometer 500 Ω • • $141

P1000A GR Feedback potentiometer 1000 Ω • • $141

P2800A GRFeedback potentiometer 2800 Ω • • $141

P5000A GR Feedback potentiometer 5000 Ω • • $141

P10000A GRFeedback potentiometer 10000 Ω • • $141

NOTE: CCV-EXT-KIT is an option for all CCVs except for B6 fl anged CCVs.NOTE: For TFR/TR actuators, no weather shield available at this time. Please call 800-543-9038 for assistance.* Designed to NEMA 4 specifi cations.NOTE: For B6 series valves, no weather shield available at this time.

Valve AccessoriesCCV

P150

01 -

04/1

4 - S

ubje

ct to

cha

nge.

© B

elim

o Ai

rcon

trols

(USA

), In

c.