CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL R801.1 Application. The provisions of this chapter shall con- trol the design and construction of the roof-ceiling system for all buildings. R801.2 Requirements. Roof and ceiling construction shall be capable of accommodating all loads imposed according to Sec- tion R301 and of transmitting the resulting loads to the support- ing structural elements. R801.3 Roof drainage. In areas where expansive or collapsible soils are known to exist, all dwellings shall have a controlled method of water disposal from roofs that will collect and dis- charge roof drainage to the ground surface at least 5 feet (1524 mm) from foundation walls or to an approved drainage system. SECTION R802 WOOD ROOF FRAMING R802.1 Identification. Load-bearing dimension lumber for rafters, trusses and ceiling joists shall be identified by a grade mark of a lumber grading or inspection agency that has been approved by an accreditation body that complies with DOC PS 20. In lieu of a grade mark, a certificate of inspection issued by a lumber grading or inspection agency meeting the require- ments of this section shall be accepted. R802.1.1 Blocking. Blocking shall be a minimum of utility grade lumber. R802.1.2 End-jointed lumber. Approved end-jointed lum- ber identified by a grade mark conforming to Section R802.1 may be used interchangeably with solid-sawn mem- bers of the same species and grade. R802.1.3 Fire-retardant-treated wood. Fire-retardant- treated wood (FRTW) is any wood product which, when impregnated with chemicals by a pressure process or other means during manufacture, shall have, when tested in accordance with ASTM E 84, a listed flame spread index of 25 or less and shows no evidence of significant progressive combustion when the test is continued for an additional 20-minute period. In addition, the flame front shall not progress more than 10.5 feet (3200 mm) beyond the center line of the burners at any time during the test. R802.1.3.1 Pressure process. For wood products impreg- nated with chemicals by a pressure process, the process shall be performed in closed vessels under pressures not less than 50 pounds per square inch gauge (psig) (344.7 kPa). R802.1.3.2 Other means during manufacture. For wood products produced by other means during manu- facture the treatment shall be an integral part of the man- ufacturing process of the wood product. The treatment shall provide permanent protection to all surfaces of the wood product. R802.1.3.3 Testing. For wood products produced by other means during manufacture, other than a pressure process, all sides of the wood product shall be tested in accordance with and produce the results required in Sec- tion R802.1.3. Testing of only the front and back faces of wood structural panels shall be permitted. R802.1.3.4 Labeling. Fire-retardant-treated lumber and wood structural panels shall be labeled. The label shall contain: 1. The identification mark of an approved agency in accordance with Section 1703.5 of the Interna- tional Building Code. 2. Identification of the treating manufacturer. 3. The name of the fire-retardant treatment. 4. The species of wood treated. 5. Flame spread index and smoke-developed index. 6. Method of drying after treatment. 7. Conformance to applicable standards in accordance with Sections R802.1.3.5 through R802.1.3.8. 8. For FRTW exposed to weather, or a damp or wet location, the words “No increase in the listed clas- sification when subjected to the Standard Rain Test” (ASTM D 2898). R802.1.3.5 Strength adjustments. Design values for untreated lumber and wood structural panels as specified in Section R802.1 shall be adjusted for fire-retardant- treated wood. Adjustments to design values shall be based upon an approved method of investigation which takes into consideration the effects of the anticipated temperature and humidity to which the fire-retar- dant-treated wood will be subjected, the type of treat- ment and redrying procedures. R802.1.3.5.1 Wood structural panels. The effect of treatment and the method of redrying after treatment, and exposure to high temperatures and high humidities on the flexure properties of fire-retar- dant-treated softwood plywood shall be determined in accordance with ASTM D 5516. The test data developed by ASTM D 5516 shall be used to develop adjustment factors, maximum loads and spans, or both for untreated plywood design values in accor- dance with ASTM D 6305. Each manufacturer shall publish the allowable maximum loads and spans for service as floor and roof sheathing for their treatment. R802.1.3.5.2 Lumber. For each species of wood treated, the effect of the treatment and the method of redrying after treatment and exposure to high temperatures and high humidities on the allowable design properties of fire-retardant-treated lumber shall be determined in accordance with ASTM D 5664. The test data developed 2009 VIRGINIA RESIDENTIAL CODE 8-1

CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

Embed Size (px)

Citation preview

Page 1: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

CHAPTER 8

ROOF-CEILING CONSTRUCTION

SECTION R801GENERAL

R801.1 Application. The provisions of this chapter shall con-trol the design and construction of the roof-ceiling system forall buildings.

R801.2 Requirements. Roof and ceiling construction shall becapable of accommodating all loads imposed according to Sec-tion R301 and of transmitting the resulting loads to the support-ing structural elements.

R801.3 Roof drainage. In areas where expansive or collapsiblesoils are known to exist, all dwellings shall have a controlledmethod of water disposal from roofs that will collect and dis-charge roof drainage to the ground surface at least 5 feet (1524mm) from foundation walls or to an approved drainage system.

SECTION R802WOOD ROOF FRAMING

R802.1 Identification. Load-bearing dimension lumber forrafters, trusses and ceiling joists shall be identified by a grademark of a lumber grading or inspection agency that has beenapproved by an accreditation body that complies with DOC PS20. In lieu of a grade mark, a certificate of inspection issued bya lumber grading or inspection agency meeting the require-ments of this section shall be accepted.

R802.1.1 Blocking. Blocking shall be a minimum of utilitygrade lumber.

R802.1.2 End-jointed lumber. Approved end-jointed lum-ber identified by a grade mark conforming to SectionR802.1 may be used interchangeably with solid-sawn mem-bers of the same species and grade.

R802.1.3 Fire-retardant-treated wood. Fire-retardant-treated wood (FRTW) is any wood product which, whenimpregnated with chemicals by a pressure process or othermeans during manufacture, shall have, when tested inaccordance with ASTM E 84, a listed flame spread index of25 or less and shows no evidence of significant progressivecombustion when the test is continued for an additional20-minute period. In addition, the flame front shall notprogress more than 10.5 feet (3200 mm) beyond the centerline of the burners at any time during the test.

R802.1.3.1 Pressure process. For wood products impreg-nated with chemicals by a pressure process, the process shallbe performed in closed vessels under pressures not less than50 pounds per square inch gauge (psig) (344.7 kPa).

R802.1.3.2 Other means during manufacture. Forwood products produced by other means during manu-facture the treatment shall be an integral part of the man-ufacturing process of the wood product. The treatmentshall provide permanent protection to all surfaces of thewood product.

R802.1.3.3 Testing. For wood products produced byother means during manufacture, other than a pressureprocess, all sides of the wood product shall be tested inaccordance with and produce the results required in Sec-tion R802.1.3. Testing of only the front and back faces ofwood structural panels shall be permitted.

R802.1.3.4 Labeling. Fire-retardant-treated lumber andwood structural panels shall be labeled. The label shallcontain:

1. The identification mark of an approved agency inaccordance with Section 1703.5 of the Interna-tional Building Code.

2. Identification of the treating manufacturer.

3. The name of the fire-retardant treatment.

4. The species of wood treated.

5. Flame spread index and smoke-developed index.

6. Method of drying after treatment.

7. Conformance to applicable standards in accordancewith Sections R802.1.3.5 through R802.1.3.8.

8. For FRTW exposed to weather, or a damp or wetlocation, the words “No increase in the listed clas-sification when subjected to the Standard RainTest” (ASTM D 2898).

R802.1.3.5 Strength adjustments. Design values foruntreated lumber and wood structural panels as specifiedin Section R802.1 shall be adjusted for fire-retardant-treated wood. Adjustments to design values shall bebased upon an approved method of investigation whichtakes into consideration the effects of the anticipatedtemperature and humidity to which the fire-retar-dant-treated wood will be subjected, the type of treat-ment and redrying procedures.

R802.1.3.5.1 Wood structural panels. The effect oftreatment and the method of redrying after treatment,and exposure to high temperatures and highhumidities on the flexure properties of fire-retar-dant-treated softwood plywood shall be determinedin accordance with ASTM D 5516. The test datadeveloped by ASTM D 5516 shall be used to developadjustment factors, maximum loads and spans, orboth for untreated plywood design values in accor-dance with ASTM D 6305. Each manufacturer shallpublish the allowable maximum loads and spans forservice as floor and roof sheathing for their treatment.

R802.1.3.5.2 Lumber. For each species of wood treated,the effect of the treatment and the method of redryingafter treatment and exposure to high temperatures andhigh humidities on the allowable design properties offire-retardant-treated lumber shall be determined inaccordance with ASTM D 5664. The test data developed

2009 VIRGINIA RESIDENTIAL CODE 8-1

1M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:06 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 2: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

by ASTM D 5664 shall be used to develop modificationfactors for use at or near room temperature and at elevatedtemperatures and humidity in accordance with ASTM D6841. Each manufacturer shall publish the modificationfactors for service at temperatures of not less than 80°F(27°C) and for roof framing. The roof framing modifica-tion factors shall take into consideration the climatologi-cal location.

R802.1.3.6Exposure to weather. Where fire-retar-dant-treated wood is exposed to weather or damp or wetlocations, it shall be identified as “Exterior” to indicate thereis no increase in the listed flame spread index as defined inSection R802.1.3 when subjected to ASTM D 2898.

R802.1.3.7Interior applications. Interior fire-retar-dant-treated wood shall have a moisture content of notover 28 percent when tested in accordance with ASTM D3201 procedures at 92 percent relative humidity. Interiorfire-retardant-treated wood shall be tested in accordancewith Section R802.1.3.5.1 or R802.1.3.5.2. Interiorfire-retardant-treated wood designated as Type A shall betested in accordance with the provisions of this section.

R802.1.3.8Moisture content. Fire-retardant-treatedwood shall be dried to a moisture content of 19 percent orless for lumber and 15 percent or less for wood structuralpanels before use. For wood kiln dried after treatment(KDAT) the kiln temperatures shall not exceed thoseused in kiln drying the lumber and plywood submittedfor the tests described in Section R802.1.3.5.1 for ply-wood and R802.1.3.5.2 for lumber.

R802.1.4 Structural glued laminated timbers. Gluedlaminated timbers shall be manufactured and identified asrequired in ANSI/AITC A190.1 and ASTM D 3737.

R802.1.5 Structural log members. Stress grading of struc-tural log members of nonrectangular shape, as typicallyused in log buildings, shall be in accordance with ASTM D3957. Such structural log members shall be identified by thegrade mark of an approved lumber grading or inspectionagency. In lieu of a grade mark on the material, a certificateof inspection as to species and grade issued by a lum-ber-grading or inspection agency meeting the requirementsof this section shall be permitted to be accepted.

R802.2 Design and construction. The framing detailsrequired in Section R802 apply to roofs having a minimumslope of three units vertical in 12 units horizontal (25-percentslope) or greater. Roof-ceilings shall be designed and con-structed in accordance with the provisions of this chapter andFigures R606.11(1), R606.11(2) and R606.11(3) or in accor-dance with AFPA/NDS. Components of roof-ceilings shall befastened in accordance with Table R602.3(1).

R802.3 Framing details. Rafters shall be framed to ridge boardor to each other with a gusset plate as a tie. Ridge board shall beat least 1-inch (25 mm) nominal thickness and not less in depththan the cut end of the rafter. At all valleys and hips there shall bea valley or hip rafter not less than 2-inch (51 mm) nominal thick-ness and not less in depth than the cut end of the rafter. Hip andvalley rafters shall be supported at the ridge by a brace to a bear-ing partition or be designed to carry and distribute the specific

load at that point. Where the roof pitch is less than three unitsvertical in 12 units horizontal (25-percent slope), structuralmembers that support rafters and ceiling joists, such as ridgebeams, hips and valleys, shall be designed as beams.

R802.3.1 Ceiling joist and rafter connections. Ceiling joistsand rafters shall be nailed to each other in accordance withTable R802.5.1(9), and the rafter shall be nailed to the top wallplate in accordance with Table R602.3(1). Ceiling joists shallbe continuous or securely joined in accordance with TableR802.5.1(9) where they meet over interior partitions and arenailed to adjacent rafters to provide a continuous tie across thebuilding when such joists are parallel to the rafters.

Where ceiling joists are not connected to the rafters at the topwallplate, joists connected higher in the attic shall be installed asrafter ties, or rafter ties shall be installed to provide a continuoustie. Where ceiling joists are not parallel to rafters, rafter ties shallbe installed. Rafter ties shall be a minimum of 2-inch by 4-inch(51 mm by 102 mm) (nominal), installed in accordance with theconnection requirements in Table R802.5.1(9), or connectionsof equivalent capacities shall be provided. Where ceiling joistsor rafter ties are not provided, the ridge formed by these raftersshall be supported by a wall or girder designed in accordancewith accepted engineering practice.

Collar ties or ridge straps to resist wind uplift shall beconnected in the upper third of the attic space in accordancewith Table R602.3(1).

Collar ties shall be a minimum of 1-inch by 4-inch (25mm by 102 mm) (nominal), spaced not more than 4 feet(1219 mm) on center.

R802.3.2 Ceiling joists lapped. Ends of ceiling joists shallbe lapped a minimum of 3 inches (76 mm) or butted overbearing partitions or beams and toenailed to the bearingmember. When ceiling joists are used to provide resistanceto rafter thrust, lapped joists shall be nailed together inaccordance with Table R802.5.1(9) and butted joists shallbe tied together in a manner to resist such thrust.

R802.4 Allowable ceiling joist spans. Spans for ceiling joistsshall be in accordance with Tables R802.4(1) and R802.4(2).For other grades and species and for other loading conditions,refer to the AF&PA Span Tables for Joists and Rafters.

R802.5 Allowable rafter spans. Spans for rafters shall be inaccordance with Tables R802.5.1(1) through R802.5.1(8). Forother grades and species and for other loading conditions, referto the AF&PA Span Tables for Joists and Rafters. The span ofeach rafter shall be measured along the horizontal projection ofthe rafter.

R802.5.1 Purlins. Installation of purlins to reduce the spanof rafters is permitted as shown in Figure R802.5.1. Purlinsshall be sized no less than the required size of the rafters thatthey support. Purlins shall be continuous and shall be sup-ported by 2-inch by 4-inch (51 mm by 102 mm) bracesinstalled to bearing walls at a slope not less than 45 degreesfrom the horizontal. The braces shall be spaced not morethan 4 feet (1219 mm) on center and the unbraced length ofbraces shall not exceed 8 feet (2438 mm).

R802.6 Bearing. The ends of each rafter or ceiling joist shallhave not less than 11/2 inches (38 mm) of bearing on wood or

8-2 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

2M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:07 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 3: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

metal and not less than 3 inches (76 mm) on masonry or con-crete.

R802.6.1 Finished ceiling material. If the finished ceilingmaterial is installed on the ceiling prior to the attachment ofthe ceiling to the walls, such as in construction at a factory, acompression strip of the same thickness as the finish ceilingmaterial shall be installed directly above the top plate ofbearing walls if the compressive strength of the finish ceil-ing material is less than the loads it will be required to with-stand. The compression strip shall cover the entire length ofsuch top plate and shall be at least one-half the width of thetop plate. It shall be of material capable of transmitting theloads transferred through it.

R802.7 Cutting and notching. Structural roof members shallnot be cut, bored or notched in excess of the limitations speci-fied in this section.

R802.7.1 Sawn lumber. Notches in solid lumber joists, raf-ters, blocking and beams shall not exceed one-sixth of thedepth of the member, shall not be longer than one-third ofthe depth of the member and shall not be located in the mid-dle one-third of the span. Notches at the ends of the membershall not exceed one-fourth the depth of the member. Thetension side of members 4 inches (102 mm) or greater innominal thickness shall not be notched except at the ends ofthe members. The diameter of the holes bored or cut intomembers shall not exceed one-third the depth of the mem-ber. Holes shall not be closer than 2 inches (51 mm) to thetop or bottom of the member, or to any other hole located inthe member. Where the member is also notched, the holeshall not be closer than 2 inches (51 mm) to the notch.

Exception: Notches on cantilevered portions of raftersare permitted provided the dimension of the remainingportion of the rafter is not less than 4-inch nominal (102mm) and the length of the cantilever does not exceed 24inches (610 mm).

R802.7.2 Engineered wood products. Cuts, notches andholes bored in trusses, structural composite lumber, struc-tural glue-laminated members or I-joists are prohibitedexcept where permitted by the manufacturer’s recommen-dations or where the effects of such alterations are specifi-cally considered in the design of the member by a registereddesign professional.

R802.8 Lateral support. Roof framing members and ceilingjoists having a depth-to-thickness ratio exceeding 5 to 1 basedon nominal dimensions shall be provided with lateral support atpoints of bearing to prevent rotation. For roof rafters with ceil-ing joists attached per Table R602.3(1), the depth-thicknessratio for the total assembly shall be determined using the com-bined thickness of the rafter plus the attached ceiling joist.

Exception: Roof trusses shall be braced in accordance withSection R802.10.3.

R802.8.1 Bridging. Rafters and ceiling joists having a depth-to-thickness ratio exceeding 6 to 1 based on nominal dimen-sions shall be supported laterally by solid blocking, diagonalbridging (wood or metal) or a continuous 1-inch by 3-inch(25 mm by 76 mm) wood strip nailed across the rafters orceiling joists at intervals not exceeding 8 feet (2438 mm).

R802.9 Framing of openings. Openings in roof and ceilingframing shall be framed with header and trimmer joists. Whenthe header joist span does not exceed 4 feet (1219 mm), theheader joist may be a single member the same size as the ceilingjoist or rafter. Single trimmer joists may be used to carry a sin-gle header joist that is located within 3 feet (914 mm) of thetrimmer joist bearing. When the header joist span exceeds 4feet (1219 mm), the trimmer joists and the header joist shall bedoubled and of sufficient cross section to support the ceilingjoists or rafter framing into the header. Approved hangers shallbe used for the header joist to trimmer joist connections whenthe header joist span exceeds 6 feet (1829 mm). Tail joists over12 feet (3658 mm) long shall be supported at the header byframing anchors or on ledger strips not less than 2 inches by 2inches (51 mm by 51 mm).

R802.10 Wood trusses.

R802.10.1 Truss design drawings. Truss design drawings,prepared in conformance to Section R802.10.1, shall beprovided to the building official and approved prior toinstallation. Truss design drawings shall include, at a mini-mum, the information specified below. Truss design draw-ing shall be provided with the shipment of trusses deliveredto the jobsite.

1. Slope or depth, span and spacing.

2. Location of all joints.

3. Required bearing widths.

4. Design loads as applicable.

4.1. Top chord live load (as determined from Sec-tion R301.6).

4.2. Top chord dead load.

4.3. Bottom chord live load.

4.4. Bottom chord dead load.

4.5. Concentrated loads and their points of appli-cation.

4.6. Controlling wind and earthquake loads.

5. Adjustments to lumber and joint connector designvalues for conditions of use.

6. Each reaction force and direction.

7. Joint connector type and description (e.g., size,thickness or gage) and the dimensioned location ofeach joint connector except where symmetricallylocated relative to the joint interface.

8. Lumber size, species and grade for each member.

9. Connection requirements for:

9.1. Truss to girder-truss.

9.2. Truss ply to ply.

9.3. Field splices.

10. Calculated deflection ratio and/or maximumdescription for live and total load.

11. Maximum axial compression forces in the trussmembers to enable the building designer to designthe size, connections and anchorage of the perma-

2009 VIRGINIA RESIDENTIAL CODE 8-3

ROOF-CEILING CONSTRUCTION

3M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:07 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 4: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

nent continuous lateral bracing. Forces shall beshown on the truss design drawing or on supplemen-tal documents.

12. Required permanent truss member bracing location.

R802.10.2 Design. Wood trusses shall be designed in accor-dance with accepted engineering practice. The design andmanufacture of metal-plate-connected wood trusses shallcomply with ANSI/TPI 1. The truss design drawings shallbe prepared by a registered professional where required bythe statutes of the jurisdiction in which the project is to beconstructed in accordance with Section R106.1.

R802.10.2.1 Applicability limits. The provisions of thissection shall control the design of truss roof framingwhen snow controls for buildings not greater than 60 feet(18 288 mm) in length perpendicular to the joist, rafter ortruss span, not greater than 36 feet (10 973 mm) in widthparallel to the joist, rafter or truss span, not greater thantwo stories in height with each story not greater than 10feet (3048 mm) high, and roof slopes not smaller than3:12 (25-percent slope) or greater than 12:12 (100-per-cent slope). Truss roof framing constructed in accor-dance with the provisions of this section shall be limitedto sites subjected to a maximum design wind speed of110 miles per hour (49 m/s), Exposure A, B or C, and amaximum ground snow load of 70 psf (3352 Pa). Forconsistent loading of all truss types, roof snow load is tobe computed as: 0.7 pg.

R802.10.3 Bracing. Trusses shall be braced to prevent rota-tion and provide lateral stability in accordance with therequirements specified in the construction documents forthe building and on the individual truss design drawings. Inthe absence of specific bracing requirements, trusses shallbe braced in accordance with the Building ComponentSafety Information (BCSI 1-03) Guide to Good Practice forHandling, Installing & Bracing of Metal Plate ConnectedWood Trusses.

R802.10.4 Alterations to trusses. Truss members shall notbe cut, notched, drilled, spliced or otherwise altered in anyway without the approval of a registered design professional.Alterations resulting in the addition of load (e.g., HVACequipment, water heater) that exceeds the design load for thetruss shall not be permitted without verification that the trussis capable of supporting such additional loading.

R802.10.5 Truss to wall connection. Trusses shall be con-nected to wall plates by the use of approved connectors havinga resistance to uplift of not less than 175 pounds (779 N) andshall be installed in accordance with the manufacturer’s speci-fications. For roof assemblies subject to wind uplift pressuresof 20 pounds per square foot (960 Pa) or greater, as establishedin Table R301.2(2), adjusted for height and exposure per TableR301.2(3), see section R802.11.

R802.11 Roof tie-down.

R802.11.1 Uplift resistance. Roof assemblies which are sub-ject to wind uplift pressures of 20 pounds per square foot (960Pa) or greater shall have roof rafters or trusses attached to theirsupporting wall assemblies by connections capable of provid-ing the resistance required in Table R802.11. Wind uplift pres-

sures shall be determined using an effective wind area of 100square feet (9.3 m2) and Zone 1 in Table R301.2(2), as adjustedfor height and exposure per Table R301.2(3).

A continuous load path shall be designed to transmit theuplift forces from the rafter or truss ties to the foundation.

8-4 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

4M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:07 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 5: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

2009 VIRGINIA RESIDENTIAL CODE 8-5

ROOF-CEILING CONSTRUCTION

TABLE R802.4(1)CEILING JOIST SPANS FOR COMMON LUMBER SPECIES

(Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)

CEILING JOISTSPACING(inches) SPECIES AND GRADE

DEAD LOAD = 5 psf

2 × 4 2 × 6 2 × 8 2 × 10

Maximum ceiling joist spans

(feet - inches) (feet - inches) (feet - inches) (feet - inches)

12

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

13-212-812-5

10-1012-512-211-7

10-1012-1112-812-511-612-2

11-1011-1010-10

20-819-1119-615-1019-619-118-215-1020-319-1119-617-019-118-818-815-10

Note aNote a25-820-125-825-224-020-1

Note aNote a25-821-825-224-724-720-1

Note aNote aNote a24-6

Note aNote aNote a24-6

Note aNote aNote a25-7

Note aNote aNote a24-6

16

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

11-1111-611-39-5

11-311-010-69-5

11-911-611-310-011-010-910-99-5

18-918-117-813-917-817-416-613-918-518-117-814-917-4

16-1116-1113-9

24-823-1023-017-523-4

22-1021-917-524-323-123-418-9

22-1022-422-417-5

Note aNote aNote a21-3

Note aNote aNote a21-3

Note aNote aNote a22-2

Note aNote aNote a21-3

19.2

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern -pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

11-310-1010-78-7

10-710-49-118-7

11-010-1010-79-1

10-410-210-28-7

17-817-016-712-616-816-415-712-617-417-016-813-616-4

15-1115-1112-6

23-322-521-0

15-1021-1121-620-6

15-1022-1022-5

21-1117-221-621-021-0

15-10

Note aNote a25-819-5

Note aNote a25-319-5

Note aNote aNote a20-3

Note a25-825-819-5

(continued)

5M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:07 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 6: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-6 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

TABLE R802.4(1)—continuedCEILING JOIST SPANS FOR COMMON LUMBER SPECIES

(Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)

CEILING JOISTSPACING(inches) SPECIES AND GRADE

DEAD LOAD = 5 psf

2 × 4 2 × 6 2 × 8 2 × 10

Maximum ceiling joist spans

(feet - inches) (feet - inches) (feet - inches) (feet - inches)

24

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

10-510-09-107-8

9-109-89-27-8

10-310-09-108-29-89-59-57-8

16-415-9

14-1011-215-615-214-511-216-115-915-612-015-214-914-911-2

21-720-118-914-220-519-718-614-221-220-1020-115-419-1118-918-914-2

Note a24-6

22-1117-4

Note a23-1122-717-4

Note aNote a23-1118-125-5

22-1122-1117-4

Check sources for availability of lumber in lengths greater than 20 feet.For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479kPa.a. Span exceeds 26 feet in length.

6M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:07 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 7: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

2009 VIRGINIA RESIDENTIAL CODE 8-7

ROOF-CEILING CONSTRUCTION

TABLE R802.4(2)CEILING JOIST SPANS FOR COMMON LUMBER SPECIES

(Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)

CEILING JOISTSPACING(inches) SPECIES AND GRADE

DEAD LOAD = 10 psf

2 × 4 2 × 6 2 × 8 2 × 10

Maximum ceiling joist spans

(feet - inches) (feet - inches) (feet - inches) (feet - inches)

12

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

10-510-09-107-89-109-89-27-810-310-09-108-29-89-59-57-8

16-415-914-1011-215-615-214-511-216-115-915-612-015-214-914-911-2

21-720-118-914-220-519-718-614-221-2

20-1020-115-4

19-1118-918-914-2

Note a24-6

22-1117-4

Note a23-1122-717-4

Note aNote a23-1118-125-5

22-1122-1117-4

16

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

9-69-18-96-8

8-118-98-46-89-49-1

8-117-18-98-78-76-8

14-1113-912-109-8

14-113-512-89-8

14-714-413-610-513-912-1012-109-8

19-717-516-312-418-6

16-1016-012-419-3

18-1117-513-318-116-316-312-4

25-021-3

19-1015-023-820-819-715-024-723-120-915-823-1

19-1019-1015-0

19.2

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

8-118-78-06-18-58-37-106-18-98-78-56-58-38-08-06-1

14-012-611-98-1013-312-311-78-1013-913-612-39-6

12-1111-911-98-10

18-515-1014-1011-317-515-614-811-318-117-9

15-1012-117-1

14-1014-1011-3

23-419-518-213-822-3

18-1117-1013-823-121-1

18-1114-421-818-218-213-8

(continued)

7M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:07 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 8: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-8 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

TABLE R802.4(2)—continuedCEILING JOIST SPANS FOR COMMON LUMBER SPECIES

(Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)

CEILING JOISTSPACING(inches) SPECIES AND GRADE

DEAD LOAD = 10 psf

2 × 4 2 × 6 2 × 8 2 × 10

Maximum ceiling joist spans

(feet - inches) (feet - inches) (feet - inches) (feet - inches)

24

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

8-37-87-25-5

7-107-67-15-58-18-07-85-97-87-27-25-5

13-011-210-67-1112-3

10-1110-47-1112-912-611-08-612-010-610-67-11

17-114-213-310-016-213-1013-110-016-1015-1014-210-1015-1013-313-310-0

20-1117-416-312-320-6

16-1116-012-321-6

18-1016-1112-1019-516-316-312-3

Check sources for availability of lumber in lengths greater than 20 feet.For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479kPa.a. Span exceeds 26 feet in length.

8M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:08 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 9: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

2009 VIRGINIA RESIDENTIAL CODE 8-9

ROOF-CEILING CONSTRUCTION

TABLE R802.5.1(1)RAFTER SPANS FOR COMMON LUMBER SPECIES

(Roof live load=20 psf, ceiling not attached to rafters, L/Δ = 180)

RAFTERSPACING(inches) SPECIES AND GRADE

DEAD LOAD = 10 psf DEAD LOAD = 20 psf

2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12

Maximum rafter spansa

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

12

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

11-611-110-108-7

10-1010 -710-18-711-311-110-109-110-710-410-48-7

18-017-416-712-617-016-815-1112-617-817-417-013-616-816-316-312-6

23-922-521-0

15-1022-5

21-1020-8

15-1023-4

22-1122-517-2

21-1121-021-0

15-10

Note bNote b25-819-5

Note bNote b25-319-5

Note bNote bNote b20-3

Note b25-825-819-5

Note bNote bNote b22-6

Note bNote bNote b22-6

Note bNote bNote b24-1

Note bNote bNote b22-6

11-610-69-107-5

10-1010-39-87-511-311-110-67-1110-79-109-107-5

18-015-414-410-1017-014-1114-210-1017-817-315-111-816-814-414-410-10

23-519-518-213-922-518-1117-1113-923-421-919-514-1021-918-218-213-9

Note b23-922-316-9

Note b23-2

21-1116-9

Note b25-1023-217-6

Note b22-322-316-9

Note bNote b25-919-6

Note bNote b25-519-6

Note bNote bNote b20-11Note b25-925-919-6

16

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

10-510-09-107-59-109-89-27-510-310-09-107-119-89-59-57-5

16-415-414-410-1015-614-1114-210-1016-115-915-111-815-214-414-410-10

21-719-518-213-920-518-1117-1113-921-220-1019-514-1019-1118-218-213-9

Note b23-922-316-9

Note b23-221-1116-9

Note b25-1023-217-625-522-322-316-9

Note bNote b25-919-6

Note bNote b25-519-6

Note bNote bNote b20-11Note b25-925-919-6

10-59-18-66-59-108-108-56-510-310-09-16-109-88-68-66-5

16-013-312-59-5

15-612-1112-39-5

16-115-013-010-114-1012-512-59-5

20-316-1015-9

11-1119-1116-515-6

11-1121-2

18-1016-1012-1018-1015-915-9

11-11

24-920-719-314-624-420-0

18-1114-6

Note b22-420-115-223-019-319-314-6

Note b23-1022-4

16-10Note b23-322-0

16-10Note bNote b23-718-1

Note b22-422-4

16-10

19.2

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

9-109-58-116-99-39-18-86-99-89-59-37-39-18-108-106-9

15-514-013-19-1114-713-812-119-1115-214-1013-910-814-313-113-19-11

20-417-916-712-719-217-416-412-7

19-1119-717-913-718-916-716-712-7

25-1121-820-315-424-621-120-015-425-523-721-216-023-1120-320-315-4

Note b25-223-617-9

Note b24-623-217-9

Note bNote b24-1019-1

Note b23-623-617-9

9-108-47-95-109-38-17-85-109-89-38-46-39-17-97-95-10

14-712-211-48-714-4

11-1011-28-715-213-8

11-119-313-711-411-48-7

18-615-414-410-1018-215-014-210-1019-1117-215-411-917-214-414-410-10

22-718-917-713-322-318-417-413-325-520-518-4

13-1021-017-717-713-3

Note b21-920-415-525-921-320-115-5

Note b24-421-616-624-420-420-415-5

(continued)

9M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:08 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 10: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-10 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

TABLE R802.5.1(1)—continuedRAFTER SPANS FOR COMMON LUMBER SPECIES

(Roof live load=20 psf, ceiling not attached to rafters, L/Δ = 180)

RAFTERSPACING(inches) SPECIES AND GRADE

DEAD LOAD = 10 psf DEAD LOAD = 20 psf

2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12

Maximum rafter spansa

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

24

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

9-18-78-06-18-78-47-116-18-118-98-76-58-58-08-06-1

14-412-611-98-1013-612-311-78-1014-113-912-39-613-311-911-98-10

18-1015-1014-1011-3

17-1015-614-811-318-617-9

15-1012-117-5

14-1014-1011-3

23-419-518-213-822-9

18-1117-1013-823-821-1

18-1114-421-818-218-213-8

Note b22-621-0

15-11Note b21-1120-9

15-11Note b25-222-217-125-221-021-0

15-11

8-117-56-115-38-77-36-105-38-118-37-55-78-46-116-115-3

13-110-1010-27-8

12-1010-710-07-8

14-112-310-88-3

12-210-210-27-8

16-713-9

12-109-916-313-512-89-918-615-413-910-615-4

12-1012-109-9

20-316-915-8

11-1019-1016-415-6

11-1022-1118-316-512-518-915-815-8

11-10

23-519-618-313-923-019-0

17-1113-9

Note b21-919-314-921-918-318-313-9

Check sources for availability of lumber in lengths greater than 20 feet.For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479kPa.a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters

on the bearing walls, such as rafter ties, is provided at that location. When ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall bemultiplied by the factors given below:

HC/HR Rafter Span Adjustment Factor

1/3 0.67

1/4 0.76

1/5 0.83

1/6 0.90

1/7.5 or less 1.00

where:HC = Height of ceiling joists or rafter ties measured vertically above the top of the rafter support walls.HR = Height of roof ridge measured vertically above the top of the rafter support walls.

b. Span exceeds 26 feet in length.

10M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:08 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 11: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

2009 VIRGINIA RESIDENTIAL CODE 8-11

ROOF-CEILING CONSTRUCTION

TABLE R802.5.1(2)RAFTER SPANS FOR COMMON LUMBER SPECIES

(Roof live load=20 psf, ceiling attached to rafters, L/Δ = 240)

RAFTERSPACING(inches) SPECIES AND GRADE

DEAD LOAD = 10 psf DEAD LOAD = 20 psf

2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12

Maximum rafter spansa

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

12

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

10-510-09-108-79-109-89-28-710-310-09-109-19-89-59-58-7

16-415-915-612-615-615-214-512-616-115-915-613-615-214-914-912-6

21-720-1020-5

15-1020-5

19-1119-0

15-1021-2

20-1020-517-2

19-1119-619-6

15-10

Note bNote b25-819-5

Note b25-524-319-5

Note bNote bNote b20-325-5

24-1024-1019-5

Note bNote bNote b22-6

Note bNote bNote b22-6

Note bNote bNote b24-1

Note bNote bNote b22-6

10-510-09-107-59-109-89-27-510-310-09-107-119-89-59-57-5

16-415-414-410-1015-614-1114-210-1016-115-915-111-815-214-414-410-10

21-719-518-213-920-518-1117-1113-921-220-1019-514-1019-1118-218-213-9

Note b23-922-316-9

Note b23-2

21-1116-9

Note b25-1023-217-625-522-322-316-9

Note bNote b25-919-6

Note bNote b25-519-6

Note bNote bNote b20-11Note b25-925-919-6

16

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

9-69-18-117-58-118-98-47-59-49-18-117-118-98-78-77-5

14-1114-414-1

10-1014-113-913-1

10-1014-714-414-111-813-913-513-5

10-10

19-718-1118-213-918-618-117-313-919-3

18-1118-6

14-1018-117-917-913-9

25-023-922-316-923-823-1

21-1116-924-724-123-217-623-122-322-316-9

Note bNote b25-919-6

Note bNote b25-519-6

Note bNote bNote b20-11Note b25-925-919-6

9-69-18-66-58-118-98-46-59-49-18-116-108-98-68-66-5

14-1113-312-59-5

14-112-1112-39-5

14-714-413-010-113-912-512-59-5

19-716-1015-9

11-1118-616-515-6

11-1119-3

18-1016-1012-1018-115-915-9

11-11

24-920-719-314-623-820-0

18-1114-624-722-420-115-223-019-319-314-6

Note b23-1022-4

16-10Note b23-322-0

16-10Note bNote b23-718-1

Note b22-422-4

16-10

19.2

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

8-118-78-56-98-58-37-106-98-98-78-57-38-38-18-16-9

14-013-613-19-1113-312-1112-49-1113-913-613-310-812-1112-812-89-11

18-517-916-712-717-517-116-312-718-117-917-513-717-116-716-712-7

23-721-820-315-422-321-120-015-423-122-821-216-021-920-320-315-4

Note b25-223-617-9

Note b24-623-217-9

Note bNote b24-1019-1

Note b23-623-617-9

8-118-47-95-108-58-17-85-108-98-78-46-38-37-97-95-10

14-012-211-48-7

13-311-1011-28-7

13-913-611-119-3

12-1111-411-48-7

18-515-414-4

10-1017-515-014-2

10-1018-117-215-411-917-114-414-4

10-10

22-718-917-713-322-318-417-413-323-120-518-4

13-1021-017-717-713-3

Note b21-920-415-525-921-320-115-5

Note b24-421-616-624-420-420-415-5

(continued)

11M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:08 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 12: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-12 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

TABLE R802.5.1(2)—continuedRAFTER SPANS FOR COMMON LUMBER SPECIES

(Roof live load=20 psf, ceiling attached to rafters, L/Δ = 240)

RAFTERSPACING(inches) SPECIES AND GRADE

DEAD LOAD = 10 psf DEAD LOAD = 20 psf

2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12

Maximum rafter spansa

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

24

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

8-38-07-106-17-107-87-36-18-18-07-106-57-87-67-66-1

13-012-611-98-1012-312-011-58-1012-912-612-39-612-011-911-98-10

17-215-1014-1011-316-215-614-811-3

16-1016-6

15-1012-1

15-1014-1014-1011-3

21-1019-518-213-820-818-1117-1013-821-621-118-1114-420-218-218-213-8

Note b22-621-015-1125-121-1120-915-11Note b25-222-217-124-721-021-015-11

8-37-5

6-115-3

7-107-3

6-105-38-18-07-55-77-8

6-116-115-3

13-010-1010-27-812-310-710-07-812-912-310-88-312-010-210-27-8

16-713-912-109-9

16-213-512-89-9

16-1015-413-910-615-412-1012-109-9

20-316-915-8

11-1019-1016-415-6

11-1021-618-316-512-518-915-815-8

11-10

23-519-618-313-923-019-0

17-1113-9

Note b21-919-314-921-918-318-313-9

Check sources for availability of lumber in lengths greater than 20 feet.For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479kPa.a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters

on the bearing walls, such as rafter ties, is provided at that location. When ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall bemultiplied by the factors given below:

HC/HR Rafter Span Adjustment Factor

1/3 0.67

1/4 0.76

1/5 0.83

1/6 0.90

1/7.5 or less 1.00

where:HC = Height of ceiling joists or rafter ties measured vertically above the top of the rafter support walls.HR = Height of roof ridge measured vertically above the top of the rafter support walls.

b. Span exceeds 26 feet in length.

12M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:09 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 13: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

2009 VIRGINIA RESIDENTIAL CODE 8-13

ROOF-CEILING CONSTRUCTION

TABLE R802.5.1(3)RAFTER SPANS FOR COMMON LUMBER SPECIES

(Ground snow load=30 psf, ceiling not attached to rafters, L/Δ = 180)

RAFTERSPACING(inches) SPECIES AND GRADE

DEAD LOAD = 10 psf DEAD LOAD = 20 psf

2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12

Maximum rafter spansa

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

12

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

10-09-89-57-19-69-38-107-19-109-89-67-79-39-19-17-1

15-914-913-910-514-1014-413-710-515-615-214-511-214-713-913-910-5

20-918-817-513-219-718-217-213-220-520-018-814-319-217-517-513-2

Note b22-921-416-125-022-221-016-1

Note b24-922-3

16-1024-621-421-416-1

Note bNote b24-818-8

Note b25-924-418-8

Note bNote bNote b20-0

Note b24-824-818-8

10-09-08-56-49-68-98-46-49-109-89-06-99-38-58-56-4

15-913-212-49-4

14-1012-1012-29-4

15-614-1012-1110-014-712-412-49-4

20-116-815-711-919-716-315-411-920-518-816-812-918-815-715-711-9

24-620-419-114-524-1

19-1018-914-5

Note b22-2

19-1115-122-919-119-114-5

Note b23-722-116-8

Note b23-021-916-8

Note bNote b23-4

17-11Note b22-122-116-8

16

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

9-18-98-26-28-78-58-06-28-118-98-76-78-58-28-26-2

14-412-9

11-119-013-612-511-99-014-113-912-69-813-3

11-1111-119-0

18-1016-215-111-517-1015-914-1111-518-618-116-212-417-515-115-111-5

23-919-918-5

13-1122-919-318-2

13-1123-821-519-314-722-118-518-5

13-11

Note b22-1021-516-2

Note b22-321-116-2

Note b25-722-717-425-721-521-516-2

9-17-107-35-68-77-77-25-6

8-118-8

7-105-108-57-37-35-6

13-911-510-88-113-611-110-68-114-1

12-1011-28-812-910-810-88-1

17-514-513-610-317-114-113-410-318-616-214-511-016-213-613-610-3

21-317-816-612-6

20-1017-216-312-623-819-217-313-019-916-616-612-6

24-820-519-214-624-2

19-1118-1014-6

Note b22-1020-215-6

22-1019-219-214-6

19.2

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

8-77-117-55-78-17-97-45-78-58-37-116-07-117-57-55-7

13-611-8

10-118-312-911-410-98-313-313-011-58-1012-5

10-1110-118-3

17-914-913-910-516-914-413-710-517-516-614-911-316-513-913-910-5

21-818-0

16-1012-921-417-716-712-922-319-717-713-420-2

16-1016-1012-9

25-220-1119-614-924-820-419-314-9

Note b23-420-7

15-1023-419-619-614-9

8-77-16-85-08-16-116-75-08-57-117-15-47-116-86-85-0

12-610-59-97-4

12-410-29-77-4

13-311-910-27-1111-89-99-97-4

15-1013-212-49-4

15-712-1012-29-4

17-514-913-210-114-912-412-49-4

19-516-115-111-519-115-8

14-1011-522-017-615-9

11-1118-015-115-111-5

22-618-817-613-222-118-217-313-225-9

20-1118-514-2

20-1117-617-613-2

(continued)

13M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:09 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 14: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-14 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

TABLE R802.5.1(3)—continuedRAFTER SPANS FOR COMMON LUMBER SPECIES

(Ground snow load=30 psf, ceiling not attached to rafters, L/Δ = 180)

RAFTERSPACING(inches) SPECIES AND GRADE

DEAD LOAD = 10 psf DEAD LOAD = 20 psf

2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12

Maximum rafter spansa

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

24

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

7-117-16-85-0

12-610-59-97-4

15-1013-212-49-4

19-516-115-111-5

22-618-817-613-2

7-86-45-114-6

11-39-48-86-7

14-211-911-08-4

17-414-513-610-2

20-116-815-7

11-107-66-116-75-07-107-87-15-47-46-86-85-0

11-1010-29-77-412-311-910-27-1111-79-99-97-4

15-712-1012-29-416-214-913-210-114-912-412-49-4

19-115-814-1011-520-817-615-911-1118-015-115-111-5

22-118-217-313-225-1

20-1118-514-2

20-1117-617-613-2

7-66-25-104-67-107-16-44-97-15-115-114-6

11-09-18-76-7

12-310-69-27-1

10-58-88-86-7

13-1111-6

10-108-416-213-211-99-013-211-011-08-4

17-014-013-310-219-815-814-110-816-113-613-610-2

19-916-315-5

11-1023-018-816-612-818-815-715-7

11-10

Check sources for availability of lumber in lengths greater than 20 feet.For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479kPa.a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters

on the bearing walls, such as rafter ties, is provided at that location. When ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall bemultiplied by the factors given below:

HC/HR Rafter Span Adjustment Factor

1/3 0.67

1/4 0.76

1/5 0.83

1/6 0.90

1/7.5 or less 1.00

where:HC = Height of ceiling joists or rafter ties measured vertically above the top of the rafter support walls.HR = Height of roof ridge measured vertically above the top of the rafter support walls.

b. Span exceeds 26 feet in length.

14M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:09 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 15: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

2009 VIRGINIA RESIDENTIAL CODE 8-15

ROOF-CEILING CONSTRUCTION

TABLE R802.5.1(4)RAFTER SPANS FOR COMMON LUMBER SPECIES

(Ground snow load=50 psf, ceiling not attached to rafters, L/Δ = 180)

RAFTERSPACING(inches) SPECIES AND GRADE

DEAD LOAD = 10 psf DEAD LOAD = 20 psf

2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12

Maximum rafter spansa

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

12

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

8-58-27-85-108-07-107-55-108-48-28-06-27-107-87-85-10

13-312-011-38-612-611-911-18-613-0

12-1011-99-212-311-311-38-6

17-615-314-310-916-614-1014-010-917-216-1015-311-816-214-314-310-9

22-418-717-513-221-118-117-213-2

21-1120-318-213-920-817-517-513-2

26-021-720-215-325-621-0

19-1115-3

Note b24-121-316-424-120-220-215-3

8-57-77-15-58-07-57-05-58-48-27-75-97-107-17-15-5

13-311-210-57-1012-610-1010-37-1013-012-610-118-5

12-310-510-57-10

17-014-113-210-016-613-913-010-017-215-914-110-915-913-213-210-0

20-917-316-112-220-416-9

15-1012-2

21-1118-9

16-1012-919-316-116-112-2

24-020-018-814-123-719-518-514-1

Note b22-419-915-222-418-818-814-1

16

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

7-87-16-85-07-36-116-75-07-67-57-15-47-16-86-85-0

12-110-59-97-411-510-29-77-4

11-1011-710-27-1111-29-99-97-4

15-1013-212-49-4

15-012-1012-29-4

15-714-913-210-114-812-412-49-4

19-516-115-111-519-115-8

14-1011-5

19-1117-615-9

11-1118-015-115-111-5

22-618-817-613-222-118-217-313-224-3

20-1118-514-220-1117-617-613-2

7-86-76-24-87-36-56-14-87-67-46-7

4-117-16-26-24-8

11-79-89-06-1011-59-58-116-10

11-1010-109-57-410-99-09-06-10

14-812-211-58-8

14-511-1111-38-8

15-713-812-29-4

13-811-511-58-8

17-1114-1113-1110-617-814-613-910-6

19-1116-214-711-0

15-1113-1113-1110-6

20-1017-316-212-320-5

16-1015-1112-3

23-1019-417-113-119-416-216-212-3

19.2

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

7-36-66-14-76-106-46-04-77-17-06-64-116-86-16-14-7

11-49-68-116-910-99-38-96-911-210-89-47-310-68-118-116-9

14-612-011-38-614-211-911-18-614-813-512-09-213-511-311-38-6

17-814-813-910-517-514-413-710-518-916-014-410-1016-513-913-910-5

20-617-1

15-1112-120-216-715-912-1

22-1019-1

16-1012-1119-1

15-1115-1112-1

7-36-05-74-36-105-105-74-37-16-86-04-66-85-75-74-3

10-78-108-36-3

10-58-78-16-3

11-29-118-86-8

9-108-38-36-3

13-511-210-57-1113-2

10-1010-37-1114-812-511-28-612-510-510-57-11

16-513-712-99-7

16-113-312-79-718 7

14-1013-410-115-312-912-99-7

19-015-914-911-218-815-514-711-221-917-815-712-017-814-914-911-2

(continued)

15M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:09 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 16: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-16 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

TABLE R802.5.1(4)—continuedRAFTER SPANS FOR COMMON LUMBER SPECIES

(Ground snow load=50 psf, ceiling not attached to rafters, L/Δ = 180)

RAFTERSPACING(inches) SPECIES AND GRADE

DEAD LOAD = 10 psf DEAD LOAD = 20 psf

2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12

Maximum rafter spansa

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

24

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

6-85-105-54-16-45-85-44-16-76-55-104-46-25-55-54-1

10-8-67-116-09-118-37-106-010-49-78-46-59-67-117-116-0

13-010-910-17-7

12-910-69-117-7

13-812-010-98-3

12-010-110-17-7

15-1013-212-49-4

15-712-1012-19-417-514-4

12-109-914-812-412-49-4

18-415-314-310-918-014-1014-110-921-017-115-111-717-114-314-310-9

6-65-55-0

3-106-45-3

4-113-106-76-05-54-16-05-05-0

3-10

9-67-107-45-79-47-87-35-7

10-48-107-96-0

8-107-47-45-7

12-010-09-47-111-99-99-27-113-811-210-07-711-29-49-47-1

14-812-211-58-7

14-511-1011-38-7

16-713-3

11-119-0

13-711-511-58-7

17-014-113-210-016-813-913-010-019-515-9

13-1110-815-913-213-210-0

Check sources for availability of lumber in lengths greater than 20 feet.For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479kPa.a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters

on the bearing walls, such as rafter ties, is provided at that location. When ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall bemultiplied by the factors given below:

HC/HR Rafter Span Adjustment Factor

1/3 0.67

1/4 0.76

1/5 0.83

1/6 0.90

1/7.5 or less 1.00

where:HC = Height of ceiling joists or rafter ties measured vertically above the top of the rafter support walls.HR = Height of roof ridge measured vertically above the top of the rafter support walls.

b. Span exceeds 26 feet in length.

16M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:09 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 17: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

2009 VIRGINIA RESIDENTIAL CODE 8-17

ROOF-CEILING CONSTRUCTION

TABLE R802.5.1(5)RAFTER SPANS FOR COMMON LUMBER SPECIES

(Ground snow load=30 psf, ceiling attached to rafters, L/Δ = 240)

RAFTERSPACING(inches) SPECIES AND GRADE

DEAD LOAD = 10 psf DEAD LOAD = 20 psf

2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12

Maximum rafter spansa

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

12

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

9-18-98-77-18-78-58-07-18-118-98-77-78-58-38-37-1

14-413-913-610-513-613-312-710-514-113-913-611-213-3

12-1112-1110-5

18-1018-217-513-217-1017-516-713-218-618-217-1014-317-517-017-013-2

24-122-921-416-122-922-221-016-123-823-222-3

16-1022-321-421-416-1

Note bNote b24-818-8

Note b25-924-418-8

Note bNote bNote b20-0

Note b24-824-818-8

9-18-98-56-48-78-58-06-48-118-98-76-98-58-38-36-4

14-413-212-49-4

13-612-1012-29-4

14-113-912-1110-013-312-412-49-4

18-1016-815-711-9

17-1016-315-411-918-618-216-812-917-515-715-711-9

24-120-419-114-522-9

19-1018-914-523-822-2

19-1115-122-319-119-114-5

Note b23-722-116-8

Note b23-021-916-8

Note bNote b23-4

17-11Note b22-122-116-8

16

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

8-38-07-106-27-107-87-36-28-18-07-106-77-87-67-66-2

13-012-6

11-119-012-312-011-59-012-912-612-39-812-011-911-99-0

17-216-215-111-516-215-914-1111-516-1016-616-212-415-1015-115-111-5

21-1019-918-5

13-1120-819-318-2

13-1121-621-119-314-720-218-518-5

13-11

Note b22-1021-516-225-122-321-116-2

Note b25-722-717-424-721-521-516-2

8-37-107-35-67-107-77-25-68-18-07-105-107-87-37-35-6

13-011-510-88-1

12-311-110-68-1

12-912-611-28-8

12-010-810-88-1

17-214-513-610-316-214-113-410-3

16-1016-214-511-0

15-1013-613-610-3

21-317-816-612-620-817-216-312-621-619-217-313-019-916-616-612-6

24-820-519-214-624-2

19-1118-1014-6

Note b22-1020-215-6

22-1019-219-214-6

19.2

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

7-97-67-45-77-47-26-105-77-87-67-46-07-27-07-05-7

12-311-8

10-118-311-711-410-98-312-011-911-58-1011-4

10-1110-118-3

16-114-913-910-515-314-413-710-515-1015-614-911-314-1113-913-910-5

20-718-0

16-1012-919-517-716-712-920-219-717-713-419-0

16-1016-1012-9

25-020-1119-614-923-720-419-314-924-723-420-7

15-1023-119-619-614-9

7-97-16-85-07-46-116-75-07-87-67-15-47-26-86-85-0

12-310-59-97-4

11-710-29-77-4

12-011-910-27-1111-49-99-97-4

15-1013-212-49-4

15-312-1012-29-4

15-1014-913-210-114-912-412-49-4

19-516-115-111-519-115-8

14-1011-520-217-615-911-1118-015-115-111-5

22-618-817-613-222-118-217-313-224-7

20-1118-514-220-1117-617-613-2

(continued)

17M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:10 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 18: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-18 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

TABLE R802.5.1(5)—continuedRAFTER SPANS FOR COMMON LUMBER SPECIES

(Ground snow load=30 psf, ceiling attached to rafters, L/Δ = 240)

RAFTERSPACING(inches) SPECIES AND GRADE

DEAD LOAD = 10 psf DEAD LOAD = 20 psf

2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12

Maximum rafter spansa

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

24

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

7-37-06-85-0

6-106-86-45-07-17-06-105-46-86-66-65-0

11-410-59-97-4

10-910-29-77-411-210-1110-27-1110-69-99-97-4

15-013-212-49-4

14-212-1012-29-4

14-814-513-210-113-1012-412-49-4

19-116-115-111-518-015-8

14-1011-518-917-615-9

11-1117-815-115-111-5

22-618-817-613-2

21-1118-217-313-2

22-1020-1118-514-2

20-1117-617-613-2

7-36-45-114-6

6-106-25-104-67-17-06-44-96-85-115-114-6

11-39-48-86-7

10-99-18-76-7

11-210-69-27-1

10-58-88-86-7

14-211-911-08-4

13-1111-610-108-4

14-813-211-99-0

13-211-011-08-4

17-414-513-610-217-014-013-310-218-915-814-110-816-113-613-610-2

20-116-815-7

11-1019-916-315-5

11-1022-1018-816-612-818-815-715-7

11-10

Check sources for availability of lumber in lengths greater than 20 feet.For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479kPa.a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters

on the bearing walls, such as rafter ties, is provided at that location. When ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall bemultiplied by the factors given below:

HC/HR Rafter Span Adjustment Factor

1/3 0.67

1/4 0.76

1/5 0.83

1/6 0.90

1/7.5 or less 1.00

where:HC = Height of ceiling joists or rafter ties measured vertically above the top of the rafter support walls.HR = Height of roof ridge measured vertically above the top of the rafter support walls.

b. Span exceeds 26 feet in length.

18M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:10 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 19: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

2009 VIRGINIA RESIDENTIAL CODE 8-19

ROOF-CEILING CONSTRUCTION

TABLE R802.5.1(6)RAFTER SPANS FOR COMMON LUMBER SPECIES

(Ground snow load=50 psf, ceiling attached to rafters, L/Δ = 240)

RAFTERSPACING(inches) SPECIES AND GRADE

DEAD LOAD = 10 psf DEAD LOAD = 20 psf

2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12

Maximum rafter spansa

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

12

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

7-87-57-35-107-37-16-95-107-67-57-36-27-16-116-115-10

12-111-711-38-611-511-210-88-6

11-1011-711-59-211-2

10-1110-118-6

15-1115-314-310-915-014-814-010-915-715-415-011-814-814-314-310-9

20-318-717-513-219-218-117-213-2

19-1119-718-213-918-917-517-513-2

24-821-720-215-323-421-0

19-1115-324-323-921-316-4

22-1020-220-215-3

7-87-57-15-57-37-16-95-57-67-57-35-97-16-116-115-5

12-111-210-57-1011-510-1010-37-1011-1011-710-118-5

11-210-510-57-10

15-1114-113-210-015-013-913-010-015-715-414-110-914-813-213-210-0

20-317-316-112-219-216-9

15-1012-2

19-1118-9

16-1012-918-916-116-112-2

24-020-018-814-123-419-518-514-124-322-419-915-222-418-818-814-1

16

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

7-06-96-75-06-76-56-25-06-106-96-75-46-56-46-45-0

11-010-59-97-410-410-29-77-410-910-710-27-1110-29-99-97-4

14-513-212-49-4

13-812-1012-29-4

14-213-1113-210-113-412-412-49-4

18-516-115-111-517-515-8

14-1011-518-117-615-9

11-1117-015-115-111-5

22-518-817-613-221-218-217-313-222-0

20-1118-514-220-917-617-613-2

7-06-76-24-86-76-56-14-86-106-96-74-116-56-26-24-8

11-09-89-0

6-1010-49-5

8-116-1010-910-79-57-4

10-29-09-0

6-10

14-512-211-58-8

13-811-1111-38-8

14-213-812-29-4

13-411-511-58-8

17-1114-1113-1110-617-514-613-910-618-116-214-711-016-8

13-1113-1110-6

20-1017-316-212-320-5

16-1015-1112-322-019-417-113-119-416-216-212-3

19.2

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

6-76-46-14-76-26-15-94-76-56-46-24-116-15-115-114-7

10-49-68-116-99-99-38-96-910-29-119-47-39-68-118-116-9

13-712-011-38-6

12-1011-911-18-6

13-413-112-09-2

12-711-311-38-6

17-414-813-910-516-514-413-710-517-016-014-4

10-1016-013-913-910-5

20-617-1

15-1112-1

19-1116-715-912-120-919-1

16-1012-1119-1

15-1115-1112-1

6-76-05-74-36-25-105-74-36-56-46-04-66-15-75-74-3

10-48-108-36-39-98-78-16-3

10-29-118-86-89-68-38-36-3

13-511-210-57-11

12-1010-1010-37-1113-412-511-28-6

12-510-510-57-11

16-513-712-99-7

16-113-312-79-7

17-014-1013-410-115-312-912-99-7

19-015-914-911-218-815-514-711-220-917-815-712-017-814-914-911-2

(continued)

19M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:10 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 20: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-20 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

TABLE R802.5.1(6)—continuedRAFTER SPANS FOR COMMON LUMBER SPECIES

(Ground snow load=50 psf, ceiling attached to rafters, L/Δ = 240)

RAFTERSPACING(inches) SPECIES AND GRADE

DEAD LOAD = 10 psf DEAD LOAD = 20 psf

2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12

Maximum rafter spansa

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

24

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

6-15-105-54-15-95-85-44-16-05-105-94-45-85-55-54-1

9-78-67-116-09-18-37-106-09-59-38-46-58-107-117-116-0

12-710-910-17-7

11-1110-69-117-712-512-010-98-311-810-110-17-7

15-1013-212-49-4

15-212-1012-19-4

15-1014-412-109-9

14-812-412-49-4

18-415-314-310-918-0

14-1014-110-919-317-115-111-717-114-314-310-9

6-15-55-03-105-95-34-113-106-05-105-54-15-85-05-03-10

9-67-107-45-79-17-87-35-79-58-107-96-08-107-47-45-7

12-010-09-47-1

11-99-99-27-1

12-511-210-07-7

11-29-49-47-1

14-812-211-58-7

14-511-1011-38-7

15-1013-3

11-119-0

13-711-511-58-7

17-014-113-210-0

15-1113-913-010-019-315-9

13-1110-815-913-213-210-0

Check sources for availability of lumber in lengths greater than 20 feet.For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479kPa.a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters

on the bearing walls, such as rafter ties, is provided at that location. When ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall bemultiplied by the factors given below:

HC/HR Rafter Span Adjustment Factor

1/3 0.67

1/4 0.76

1/5 0.83

1/6 0.90

1/7.5 or less 1.00

where:HC = Height of ceiling joists or rafter ties measured vertically above the top of the rafter support walls.HR = Height of roof ridge measured vertically above the top of the rafter support walls.

20M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:10 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 21: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

2009 VIRGINIA RESIDENTIAL CODE 8-21

ROOF-CEILING CONSTRUCTION

TABLE R802.5.1(7)RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD

(Ceiling not attached to rafters, L/Δ = 180)

RAFTERSPACING(inches) SPECIES AND GRADE

DEAD LOAD = 10 psf DEAD LOAD = 20 psf

2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12

Maximum Rafter Spansa

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

(feet-inches)

12

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

7-77-16-85-07-26-116-75-07-57-37-15-47-06-86-85-0

11-1010-59-97-4

11-310-29-77-4

11-811-510-27-1111-09-99-97-4

15-813-212-49-4

14-912-1012-29-4

15-414-913-210-114-612-412-49-4

19-516-115-111-5

18-1015-8

14-1011-519-717-615-9

11-1118-015-115-111-5

22-618-817-613-222-118-217-313-2

23-1020-1118-514-2

20-1117-617-613-2

7-76-86-34-97-26-66-24-97-57-36-85-17-06-36-34-9

11-109-109-2

6-1111-39-79-1

6-1111-811-19-77-5

11-09-29-2

6-11

15-012-511-88-9

14-812-111-58-9

15-413-1112-59-6

13-1111-811-88-9

18-315-214-210-918-0

14-1014-010-919-716-6

14-1011-317-014-214-210-9

21-217-716-612-5

20-1017-216-312-5

23-1019-817-513-419-816-616-612-5

16

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

6-106-25-94-46-66-05-84-46-96-76-24-86-45-95-94-4

10-99-08-56-4

10-28-98-46-4

10-710-28-106-1010-08-58-56-4

13-911-510-88-1

13-511-210-68-1

14-012-911-58-9

12-910-810-88-1

16-1013-1113-19-1016-613-712-109-10

17-1015-213-710-415-713-113-19-10

19-616-215-211-519-215-9

14-1111-521-818-116-012-318-115-215-211-5

6-105-105-54-16-65-85-44-16-96-55-104-46-45-55-54-1

10-38-6

7-116-0

10-18-3

7-106-0

10-79-78-46-59-6

7-117-116-0

13-010-910-17-7

12-910-69-117-7

14-012-010-98-3

12-010-110-17-7

15-1013-212-49-4

15-712-1012-19-4

17-1014-4

12-109-9

14-812-412-49-4

18-415-314-310-918-0

14-1014-110-921-017-115-111-717-114-314-310-9

19.2

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

6-55-75-34-06-15-65-24-06-46-35-74-36-05-35-34-0

9-118-37-85-109-78-07-75-1010-09-38-16-39-27-87-85-10

12-710-59-97-4

12-410-29-77-4

13-211-810-58-0

11-89-99-97-4

15-412-911-11

9-015-112-511-99-0

16-913-1012-59-5

14-311-1111-11

9-0

17-914-9

13-1010-517-414-513-710-520-416-614-711-216-6

13-1013-1010-5

6-55-45-03-96-15-24-113-96-45-115-44-05-115-05-03-9

9-47-97-35-69-27-77-25-6

10-08-97-7

5-118-87-37-35-6

11-109-109-2

6-1111-89-79-1

6-1113-211-09-107-6

11-09-29-2

6-11

14-512-011-38-6

14-211-811-18-6

16-513-111-98-1013-511-311-38-6

16-913-1113-09-1015-513-712-109-1019-215-713-910-715-713-013-09-10

(continued)

21M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:11 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 22: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-22 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

TABLE R802.5.1(7)—continuedRAFTER SPANS FOR 70 PSF GROUND SNOW LOAD

(Ceiling not attached to rafters, L/Δ = 180)

RAFTERSPACING(inches) SPECIES AND GRADE

DEAD LOAD = 10 psf DEAD LOAD = 20 psf

2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12

Maximum rafter spansa

(feet-inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

24

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

6-05-04-83-75-84-114-83-75-115-75-03-95-64-84-83-7

8-107-46-115-28-87-26-95-29-38-37-35-78-36-116-115-2

11-39-48-96-7

11-09-18-76-7

12-210-59-47-1

10-58-98-96-7

13-911-510-88-1

13-611-110-68-1

15-712-511-18-5

12-910-810-88-1

15-1113-212-49-4

13-1112-1012-29-4

18-214-913-010-014-912-412-49-4

5-94-94-53-45-74-74-43-4

5-115-34-93-75-44-54-53-4

8-46-116-6

4-118-36-96-5

4-119-3

7-106-105-37-96-66-6

4-11

10-78-98-36-3

10-58-78-16-3

12-29-108-96-99-108-38-36-3

12-1110-910-07-7

12-410-69-117-7

14-811-810-67-1112-010-010-07-7

15-012-511-88-1012-412-211-68-1017-2

13-1112-49-5

12-1111-811-88-10

Check sources for availability of lumber in lengths greater than 20 feet.For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479kPa.a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters

on the bearing walls, such as rafter ties, is provided at that location. When ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall bemultiplied by the factors given below:

HC/HR Rafter Span Adjustment Factor

1/3 0.67

1/4 0.76

1/5 0.83

1/6 0.90

1/7.5 or less 1.00

where:HC = Height of ceiling joists or rafter ties measured vertically above the top of the rafter support walls.HR = Height of roof ridge measured vertically above the top of the rafter support walls.

22M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:11 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 23: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

2009 VIRGINIA RESIDENTIAL CODE 8-23

ROOF-CEILING CONSTRUCTION

TABLE R802.5.1(8)RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD

(Ceiling attached to rafters, L/Δ = 240)

RAFTERSPACING(inches) SPECIES AND GRADE

DEAD LOAD = 10 psf DEAD LOAD = 20 psf

2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12

Maximum rafter spansa

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

12

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

6-106-76-65-06-66-46-15-06-96-76-65-46-46-26-25-0

10-910-59-97-4

10-210-09-67-4

10-710-510-27-1110-09-99-97-4

14-313-212-49-4

13-512-1012-29-4

14-013-813-210-113-212-412-49-4

18-216-115-111-517-215-814-1011-517-1017-615-911-1116-915-115-111-5

22-118-817-613-2

20-1018-217-313-221-8

20-1118-514-220-517-617-613-2

6-106-76-34-96-66-46-14-96-96-76-65-16-46-26-24-9

10-99-109-2

6-1110-29-79-1

6-1110-710-59-77-5

10-09-29-2

6-11

14-312-511-88-9

13-512-111-58-9

14-013-812-59-6

13-211-811-88-9

18-215-214-210-917-2

14-1014-010-9

17-1016-6

14-1011-316-914-214-210-9

21-217-716-612-5

20-1017-216-312-521-819-817-513-419-816-616-612-5

16

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

6-36-05-94-45-115-95-64-46-16-05-114-85-95-85-84-4

9-109-08-56-49-38-98-46-49-79-58-106-109-18-58-56-4

12-1111-510-88-1

12-211-210-68-1

12-812-511-58-9

11-1110-810-88-1

16-613-1113-19-1015-713-712-109-1016-215-213-710-415-313-113-19-10

19-616-215-211-518-1115-914-1111-519-818-116-012-318-115-215-211-5

6-35-105-54-1

5-115-85-44-16-16-0

5-104-45-95-55-54-1

9-108-67-116-09-38-37-106-09-79-58-46-59-17-117-116-0

12-1110-910-17-7

12-210-69-117-7

12-812-010-98-3

11-1110-110-17-7

15-1013-212-49-4

15-712-1012-19-4

16-214-4

12-109-9

14-812-412-49-4

18-415-314-310-918-0

14-1014-110-919-817-115-111-717-114-314-310-9

19.2

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

5-105-75-34-05-65-55-24-05-95-85-64-35-55-35-34-0

9-38-37-8

5-108-88-07-7

5-109-1

8-118-16-38-67-87-8

5-10

12-210-59-97-4

11-610-29-77-4

11-1111-810-58-0

11-39-99-97-4

15-412-9

11-119-0

14-812-511-99-0

15-313-1012-59-5

14-311-1111-11

9-0

17-914-913-1010-517-414-513-710-518-616-614-711-216-613-1013-1010-5

5-105-45-03-95-65-2

4-113-95-95-85-44-05-55-05-03-9

9-37-97-35-68-87-77-25-69-18-97-7

5-118-67-37-35-6

11-109-109-2

6-1111-69-79-1

6-1111-1111-09-107-6

11-09-29-2

6-11

14-512-011-38-6

14-211-811-18-6

15-313-111-98-1013-511-311-38-6

16-913-1113-09-1015-513-712-109-1018-615-713-910-715-713-013-09-10

(continued)

23M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:11 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 24: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-24 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

TABLE R802.5.1(8)—continuedRAFTER SPANS FOR 70 PSF GROUND SNOW LOADa

(Ceiling attached to rafters, L/Δ = 240)

RAFTERSPACING(inches) SPECIES AND GRADE

DEAD LOAD = 10 psf DEAD LOAD = 20 psf

2 × 4 2 × 6 2 × 8 2 × 10 2 × 12 2 × 4 2 × 6 2 × 8 2 × 10 2 × 12

Maximum rafter spansa

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

(feet -inches)

24

Douglas fir-larch SSDouglas fir-larch #1Douglas fir-larch #2Douglas fir-larch #3Hem-fir SSHem-fir #1Hem-fir #2Hem-fir #3Southern pine SSSouthern pine #1Southern pine #2Southern pine #3Spruce-pine-fir SSSpruce-pine-fir #1Spruce-pine-fir #2Spruce-pine-fir #3

5-55-04-83-75-24-114-83-75-45-35-03-95-04-84-83-7

8-77-46-115-28-17-26-95-28-58-37-35-77-116-116-115-2

11-39-48-96-7

10-89-18-76-7

11-110-59-47-1

10-58-98-96-7

13-911-510-88-1

13-611-110-68-1

14-212-511-18-5

12-910-810-88-1

15-1113-212-49-4

13-1112-1012-29-4

17-214-913-010-014-912-412-49-4

5-54-94-53-45-24-74-43-45-45-34-93-75-04-54-53-4

8-46-116-6

4-118-16-96-5

4-118-5

7-106-105-37-96-66-6

4-11

10-78-98-36-3

10-58-78-16-3

11-19-108-96-99-108-38-36-3

12-1110-910-07-7

12-410-69-117-7

14-211-810-67-1112-010-010-07-7

15-012-511-88-1012-412-211-68-1017-2

13-1112-49-5

12-1111-811-88-10

Check sources for availability of lumber in lengths greater than 20 feet.For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479kPa.a. The tabulated rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters

on the bearing walls, such as rafter ties, is provided at that location. When ceiling joists or rafter ties are located higher in the attic space, the rafter spans shall bemultiplied by the factors given below:

HC/HR Rafter Span Adjustment Factor

1/3 0.67

1/4 0.76

1/5 0.83

1/6 0.90

1/7.5 or less 1.00

where:HC = Height of ceiling joists or rafter ties measured vertically above the top of the rafter support walls.HR = Height of roof ridge measured vertically above the top of the rafter support walls.

24M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:11 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 25: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

2009 VIRGINIA RESIDENTIAL CODE 8-25

ROOF-CEILING CONSTRUCTION

TABLE R802.5.1(9)RAFTER/CEILING JOIST HEEL JOINT CONNECTIONSa, b, c, d, e, f, h

RAFTERSLOPE

RAFTERSPACING(inches)

GROUND SNOW LOAD (psf)

20g 30 50 70

Roof span (feet)

12 20 28 36 12 20 28 36 12 20 28 36 12 20 28 36

Required number of 16d common nailsa, b per heel joint splicesc, d, e, f

3:12121624

457

6811

81015

101319

457

6811

81116

111421

569

81116

121523

152030

6812

111421

152030

202639

4:12121624

345

568

6812

81015

345

569

68

12

81116

457

68

12

91217

111522

569

81116

121523

152029

5:12121624

334

457

569

6812

334

457

57

10

79

13

346

57

10

79

14

91218

457

79

13

91218

121623

7:12121624

333

445

457

569

333

345

457

569

334

457

57

10

79

13

345

569

79

13

91117

9:12121624

333

344

446

457

333

334

346

457

333

346

458

57

10

334

457

57

10

79

13

12:12121624

333

334

344

345

333

333

334

346

333

334

346

458

333

346

458

57

10

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479kPa.a. 40d box nails shall be permitted to be substituted for 16d common nails.b. Nailing requirements shall be permitted to be reduced 25 percent if nails are clinched.c. Heel joint connections are not required when the ridge is supported by a load-bearing wall, header or ridge beam.d. When intermediate support of the rafter is provided by vertical struts or purlins to a loadbearing wall, the tabulated heel joint connection requirements shall be per-

mitted to be reduced proportionally to the reduction in span.e. Equivalent nailing patterns are required for ceiling joist to ceiling joist lap splices.f. When rafter ties are substituted for ceiling joists, the heel joint connection requirement shall be taken as the tabulated heel joint connection requirement for

two-thirds of the actual rafter-slope.g. Applies to roof live load of 20 psf or less.h. Tabulated heel joint connection requirements assume that ceiling joists or rafter ties are located at the bottom of the attic space. When ceiling joists or rafter ties are

located higher in the attic, heel joint connection requirements shall be increased by the following factors:

HC/HR

Heel Joint ConnectionAdjustment Factor

1/3 1.5

1/4 1.33

1/5 1.25

1/6 1.2

1/10 or less 1.11

where:HC = Height of ceiling joists or rafter ties measured vertically above the top of the rafter support walls.HR = Height of roof ridge measured vertically above the top of the rafter support walls.

25M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:12 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 26: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-26 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

TABLE R802.11REQUIRED STRENGTH OF TRUSS OR RAFTER CONNECTIONS TO RESIST WIND UPLIFT FORCESa, b, c, e

(Pounds per connection)

BASIC WIND SPEED(mph) (3–second gust)

ROOF SPAN (feet) OVERHANGSd

(pounds/foot)12 20 24 28 32 36 40

85 -72 -120 -145 -169 -193 -217 -241 -38.55

90 -91 -151 -181 -212 -242 -272 -302 -43.22

100 -131 -218 -262 -305 -349 -393 -436 -53.36

110 -175 -292 -351 -409 -467 -526 -584 -64.56

For SI: 1 inch = 25.4 mm, 1 foot = 305 mm, 1 mph = 0.447 m/s, 1 pound/foot = 14.5939 N/m, 1 pound = 0.454 kg.a. The uplift connection requirements are based on a 30 foot mean roof height located in Exposure B. For Exposures C and D and for other mean roof heights, multi-

ply the above loads by the Adjustment Coefficients in Table R301.2(3).b. The uplift connection requirements are based on the framing being spaced 24 inches on center. Multiply by 0.67 for framing spaced 16 inches on center and multi-

ply by 0.5 for framing spaced 12 inches on center.c. The uplift connection requirements include an allowance for 10 pounds of dead load.d. The uplift connection requirements do not account for the effects of overhangs. The magnitude of the above loads shall be increased by adding the overhang loads

found in the table. The overhang loads are also based on framing spaced 24 inches on center. The overhang loads given shall be multiplied by the overhang projec-tion and added to the roof uplift value in the table.

e. The uplift connection requirements are based on wind loading on end zones as defined in Figure 6-2 of ASCE 7. Connection loads for connections located a dis-tance of 20% of the least horizontal dimension of the building from the corner of the building are permitted to be reduced by multiplying the table connection valueby 0.7 and multiplying the overhang load by 0.8.

RIDGE BOARD

PURLIN SAME SIZE ASRAFTER. SEE SECTION

R802.5.1

2 IN. x 4 IN. PURLINSUPPORT BRACE

AT 4 FT. O.C.

PURLIN CONTINUOUSBETWEEN SUPPORTBRACES

NAIL TO JOIST

TOP PLATE CEILING JOIST*SEE TABLES R802.4(1)AND R802.4(2)

45° MIN

RAFTER SPANSEE TABLES R802.5.1(1)THROUGH R802.5.1(8)

BEARINGPARTITIONS

For SI: 1 inch = 25.4 mm, 1 foot = 305 mm, 1 degree = 0.018 rad.Note: Where ceiling joints run perpendicular to the rafters, rafter ties shall be nailed to each rafter near the top of the ceiling joist.

FIGURE R802.5.1BRACED RAFTER CONSTRUCTION

26M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:12 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 27: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

SECTION R803ROOF SHEATHING

R803.1 Lumber sheathing. Allowable spans for lumber used asroof sheathing shall conform to Table R803.1. Spaced lumbersheathing for wood shingle and shake roofing shall conform tothe requirements of Sections R905.7 and R905.8. Spaced lum-ber sheathing is not allowed in Seismic Design Category D2.

TABLE R803.1MINIMUM THICKNESS OF LUMBER ROOF SHEATHING

RAFTER OR BEAM SPACING(inches)

MINIMUM NET THICKNESS(inches)

24 5/8

48a

11/2 T & G60b

72c

For SI: 1 inch = 25.4 mm.a. Minimum 270 Fb, 340,000 E.b. Minimum 420 Fb, 660,000 E.c. Minimum 600 Fb, 1,150,000 E.

R803.2 Wood structural panel sheathing.

R803.2.1 Identification and grade. Wood structuralpanels shall conform to DOC PS 1, DOC PS 2 or, whenmanufactured in Canada, CSA O437 or CSA O325, andshall be identified by a grade mark or certificate of inspec-tion issued by an approved agency. Wood structural panelsshall comply with the grades specified in TableR503.2.1.1(1).

R803.2.1.1 Exposure durability. All wood structuralpanels, when designed to be permanently exposed in out-door applications, shall be of an exterior exposure dura-bility. Wood structural panel roof sheathing exposed tothe underside may be of interior type bonded with exte-rior glue, identified as Exposure 1.

R803.2.1.2 Fire-retardant-treated plywood. The allow-able unit stresses for fire-retardant-treated plywood, includ-ing fastener values, shall be developed from an approvedmethod of investigation that considers the effects of antici-pated temperature and humidity to which the fire-retar-dant-treated plywood will be subjected, the type oftreatment and redrying process. The fire-retardant- treatedplywood shall be graded by an approved agency.

R803.2.2 Allowable spans. The maximum allowable spansfor wood structural panel roof sheathing shall not exceed thevalues set forth in Table R503.2.1.1(1), or APA E30.

R803.2.3 Installation. Wood structural panel used as roofsheathing shall be installed with joints staggered or not stag-gered in accordance with Table R602.3(1), or APA E30 forwoodroof framingorwithTableR804.3 for steel roof framing.

SECTION R804STEEL ROOF FRAMING

R804.1 General. Elements shall be straight and free of anydefects that would significantly affect their structural perfor-mance. Cold-formed steel roof framing members shall complywith the requirements of this section.

R804.1.1 Applicability limits. The provisions of this sec-tion shall control the construction of cold-formed steel roofframing for buildings not greater than 60 feet (18 288 mm)perpendicular to the joist, rafter or truss span, not greaterthan 40 feet (12 192 mm) in width parallel to the joist span ortruss, less than or equal to three stories above grade planeand with roof slopes not less than 3:12 (25-percent slope) orgreater than 12:12 (100 percent slope). Cold-formed steelroof framing constructed in accordance with the provisionsof this section shall be limited to sites subjected to a maxi-mum design wind speed of 110 miles per hour (49 m/s),Exposure B or C, and a maximum ground snow load of 70pounds per square foot (3350 Pa).

R804.1.2 In-line framing. Cold-formed steel roof framingconstructed in accordance with Section R804 shall belocated in line with load-bearing studs in accordance withFigure R804.1.2 and the tolerances specified as follows:

1. The maximum tolerance shall be 3/4 inch (19.1 mm)between the centerline of the horizontal framingmember and the centerline of the vertical framingmember.

2. Where the centerline of the horizontal framing mem-ber and bearing stiffener are located to one side of thecenter line of the vertical framing member, the maxi-mum tolerance shall be 1/8 inch (3 mm) between theweb of the horizontal framing member and the edgeof the vertical framing member.

R804.2 Structural framing. Load-bearing cold-formed steelroof framing members shall comply with Figure R804.2(1) andwith the dimensional and minimum thickness requirementsspecified in Tables R804.2(1) and R804.2(2). Tracks shallcomply with Figure R804.2(2) and shall have a minimumflange width of 11/4 inches (32 mm). The maximum inside bendradius for members shall be the greater of 3/32 inch (2.4 mm)minus half the base steel thickness or 1.5 times the base steelthickness.

R804.2.1 Material. Load-bearing cold-formed steel fram-ing members shall be cold-formed to shape from structuralquality sheet steel complying with the requirements of oneof the following:

1. ASTM A 653: Grades 33 and 50 (Class 1 and 3).

2. ASTM A 792: Grades 33 and 50A.

3. ASTM A 1003: Structural Grades 33 Type H and 50Type H.

R804.2.2 Identification. Load-bearing cold-formed steelframing members shall have a legible label, stencil, stampor embossment with the following information as a mini-mum:

1. Manufacturer’s identification.

2. Minimum base steel thickness in inches (mm).

3. Minimum coating designation.

4. Minimum yield strength, in kips per square inch (ksi)(MPa).

2009 VIRGINIA RESIDENTIAL CODE 8-27

ROOF-CEILING CONSTRUCTION

27M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:12 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 28: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-28 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

HORIZONTALFRAMINGMEMBER

HORIZONTALFRAMINGMEMBER

BEARING STIFFENER

TRACK

STUD

BEARINGSTIFFENER

HORIZONTALFRAMINGMEMBER

HORIZONTALFRAMINGMEMBER

HORIZONTALFRAMINGMEMBER

¾ (19 mm)

MAX.

″¾ (19 mm)

MAX.

″¾ (19 mm)

MAX.

VERTICALFRAMINGMEMBER

VERTICALFRAMINGMEMBER

VERTICALFRAMINGMEMBER

18/ (3mm) MAX.

FROM WEB OFHORIZONTALFRAMINGMEMBER TOEDGE OFVERTICALFRAMINGMEMBER

BEARING STIFFENER

TRACK

STUD

STUDCL

CL CL CL

CLCLCL

CL

For SI: 1 inch = 25.4 mm.

FIGURE R804.1.2IN-LINE FRAMING

TABLE R804.2(1)LOAD-BEARING COLD-FORMED STEEL MEMBER SIZES

NOMINAL MEMBER SIZEMEMBER DESIGNATIONa

WEB DEPTH(inches)

MINIMUM FLANGE WIDTH(inches)

MAXIMUM FLANGE WIDTH(inches)

MINIMUM LIP SIZE(inches)

350S162-t 3.5 1.625 2 0.5

550S162-t 5.5 1.625 2 0.5

800S162-t 8 1.625 2 0.5

1000S162-t 10 1.625 2 0.5

1200S162-t 12 1.625 2 0.5

For SI: 1 inch = 25.4 mm.a. The member designation is defined by the first number representing the member depth in hundredths of an inch, the letter “s” representing a stud or joist member, the

second number representing the flange width in hundredths of an inch, and the letter “t” shall be a number representing the minimum base metal thickness in mils [seeTable R804.2(2)].

TABLE R804.2(2)MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS

DESIGNATION THICKNESS (mils) MINIMUM BASE STEEL THICKNESS (inches)

33 0.0329

43 0.0428

54 0.0538

68 0.0677

97 0.0966

For SI: 1 inch = 25.4 mm, 1 mil = 0.0254 mm.

28M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:12 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 29: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

R804.2.3 Corrosion protection. Load-bearing cold-formedsteel framing shall have a metallic coating complying withASTM A 1003 and one of the following:

1. A minimum of G 60 in accordance with ASTM A653.

2. A minimum of AZ 50 in accordance with ASTM A792.

R804.2.4 Fastening requirements. Screws for steel-to-steelconnections shall be installed with a minimum edge distanceand center-to-center spacing of 1/2 inch (13 mm), shall beself-drilling tapping, and shall conform to ASTM C 1513.Structural sheathing shall be attached to cold-formed steelroof rafters with minimum No. 8 self-drilling tapping screwsthat conform to ASTM C 1513. Screws for attaching struc-tural sheathing to cold-formed steel roof framing shall have aminimum head diameter of 0.292 inch (7.4 mm) with coun-tersunk heads and shall be installed with a minimum edgedistance of 3/8 inch (10 mm). Gypsum board ceilings shall beattached to cold-formed steel joists with minimum No. 6screws conforming to ASTM C 954 or ASTM C 1513 with abugle head style and shall be installed in accordance withSection R805. For all connections, screws shall extendthrough the steel a minimum of three exposed threads. Allfasteners shall have rust inhibitive coating suitable for theinstallation in which they are being used, or be manufacturedfrom material not susceptible to corrosion.

Where No. 8 screws are specified in a steel-to-steel con-nection, reduction of the required number of screws in theconnection is permitted in accordance with the reductionfactors in Table R804.2.4 when larger screws are used orwhen one of the sheets of steel being connected is thickerthan 33 mils (0.84 mm). When applying the reduction fac-tor, the resulting number of screws shall be rounded up.

TABLE R804.2.4SCREW SUBSTITUTION FACTOR

SCREW SIZE

THINNEST CONNECTED STEEL SHEET (mils)

33 43

#8 1.0 0.67

#10 0.93 0.62

#12 0.86 0.56

For SI: 1 mil = 0.0254 mm.

R804.2.5 Web holes, web hole reinforcing and web holepatching. Web holes, web hole reinforcing, and web holepatching shall be in accordance with this section.

R804.2.5.1 Web holes. Web holes in roof framing mem-bers shall comply with all of the following conditions:

1. Holes shall conform to Figure R804.2.5.1;

2. Holes shall be permitted only along the centerlineof the web of the framing member;

3. Center-to-center spacing of holes shall not be lessthan 24 inches (610 mm);

4. The web hole width shall not be greater thanone-half the member depth, or 21/2 inches (64.5mm);

5. Holes shall have a web hole length not exceeding41/2 inches (114 mm); and

6. The minimum distance between the edge of thebearing surface and the edge of the web hole shallnot be less than 10 inches (254 mm).

Framing members with web holes not conforming tothe above requirements shall be reinforced in accordancewith Section R804.2.5.2, patched in accordance with

2009 VIRGINIA RESIDENTIAL CODE 8-29

ROOF-CEILING CONSTRUCTION

FIGURE R804.2(1)C-SHAPED SECTION

FIGURE R804.2(2)TRACK SECTION

29M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:14 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 30: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

Section R804.2.5.3 or designed in accordance withaccepted engineering practices.

R804.2.5.2 Web hole reinforcing. Reinforcement ofweb holes in ceiling joists not conforming to the require-ments of Section R804.2.5.1 shall be permitted if thehole is located fully within the center 40 percent of thespan and the depth and length of the hole does not exceed65 percent of the flat width of the web. The reinforcingshall be a steel plate or C-shape section with a hole thatdoes not exceed the web hole size limitations of SectionR804.2.5.1 for the member being reinforced. The steelreinforcing shall be the same thickness as the receivingmember and shall extend at least 1 inch (25.4 mm)beyond all edges of the hole. The steel reinforcing shallbe fastened to the web of the receiving member withNo.8 screws spaced no greater than 1 inch (25.4 mm)center-to-center along the edges of the patch with mini-mum edge distance of 1/2 inch (13 mm).

R804.2.5.3 Hole patching. Patching of web holes inroof framing members not conforming to the require-ments in Section R804.2.5.1 shall be permitted in accor-dance with either of the following methods:

1. Framing members shall be replaced or designed inaccordance with accepted engineering practiceswhere web holes exceed the following size limits:

1.1. The depth of the hole, measured across theweb, exceeds 70 percent of the flat width ofthe web; or

1.2. The length of the hole measured along theweb, exceeds 10 inches (254 mm) or thedepth of the web, whichever is greater.

2. Web holes not exceeding the dimensional require-ments in Section R804.2.5.3, Item 1, shall bepatched with a solid steel plate, stud section ortrack section in accordance with FigureR804.2.5.3. The steel patch shall, as a minimum,be the same thickness as the receiving member andshall extend at least 1 inch (25 mm) beyond all

edges of the hole. The steel patch shall be fastenedto the web of the receiving member with No.8screws spaced no greater than 1 inch (25 mm) cen-ter-to-center along the edges of the patch with min-imum edge distance of 1/2 inch (13 mm).

R804.3 Roof construction. Cold-formed steel roof systemsconstructed in accordance with the provisions of this sectionshall consist of both ceiling joists and rafters in accordancewith Figure R804.3 and fastened in accordance with TableR804.3, and hip framing in accordance with Section R804.3.3.

R804.3.1 Ceiling joists. Cold-formed steel ceiling joistsshall be in accordance with this section.

R804.3.1.1 Minimum ceiling joist size. Ceiling joistsize and thickness shall be determined in accordance

8-30 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

For SI: 1 inch = 25.4 mm.

FIGURE R804.2.5.1WEB HOLES

SOLID STEEL PLATE,C-SHAPE OR TRACK,MIN. THICKNESS ASJOIST

JOIST

NO. 8 SCREWSSPACED AT 1 IN. O.C.(TYP.)

For SI: 1 inch = 25.4 mm.

FIGURE R804.2.5.3WEB HOLE PATCH

30M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:17 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 31: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

with the limits set forth in Tables R804.3.1.1(1) throughR804.3.1.1(8). When determining the size of ceilingjoists, the lateral support of the top flange shall be classi-fied as unbraced, braced at mid-span or braced at thirdpoints in accordance with Section R804.3.1.4. Wheresheathing material is attached to the top flange of ceilingjoists or where the bracing is spaced closer than third

point of the joists, the “third point” values from TablesR804.3.1.1(1) through R804.3.1.1(8) shall be used.

Ceiling joists shall have a bearing support length ofnot less than 11/2 inches (38 mm) and shall be connectedto roof rafters (heel joint) with No. 10 screws in accor-dance with Figures R804.3.1.1(1) and R804.3.1.1(2) andTable 804.3.1.1(9).

2009 VIRGINIA RESIDENTIAL CODE 8-31

ROOF-CEILING CONSTRUCTION

CEILING JOIST

½ IN. GYPSUM BOARD

6 IN. MAX. TO CENTEROF SCREW PATTERN

350s162-33 MIL C- OR TRACKSECTION OR STRAP FOR CEILING

JOIST TOP FLANGE BRACING

C-SECTION OR TRACK INSTALLEDAT 4 FT. O.C. TO RAFTER SUPPORT BRACE

RAFTER BOTTOM FLANGEBRACING (FLAT STRAP,350S162-33 MIL C-SECTION,OR TRACK SECTION)

RAFTER SPANWITHOUT RAFTER SUPPORT BRACE

RIDGE MEMBERSEE FIGURE R804.3.2.4

RAFTER

RAFTER SPANWITH RAFTER SUPPORT BRACE

45°MIN

EAVE OVERHANG2 FT. MAX.

HEEL JOINTSEE FIGURER804.3.1(1)

CEILING JOIST SPAN

LOAD-BEARING WALL SHALL BEINSTALLED WHEN RAFTER BRACEIS USED

LOAD-BEARING WALL

LOAD-BEARING WALL

WHEN INSTALLED RAFTER SUPPORTBRACE SHALL BE A MINIMUM OF350s162-33 MIL C-SECTION, CONNECTEDTO EACH CEILING JOIST AND RAFTERWITH 4 SCREWS AT EACH END (COPEFLANGES OF BRA AT CEILING JOISTCONNECTION OR USE GUSSET PLATE)

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mil = 0.0254 mm.

FIGURE R804.3STEEL ROOF CONSTRUCTION

TABLE R804.3ROOF FRAMING FASTENING SCHEDULEa, b

DESCRIPTION OF BUILDING ELEMENTS NUMBER AND SIZE OF FASTENERS SPACING OF FASTENERS

Ceiling joist to top track of load-bearing wall 2 No. 10 screws Each joist

Roof sheathing (oriented strand board or plywood)to rafters No. 8 screws 6″ o.c. on edges and 12″ o.c. at interior supports.

6″ o.c. at gable end truss

Truss to bearing walla 2 No. 10 screws Each truss

Gable end truss to endwall top track No. 10 screws 12″ o.c.

Rafter to ceiling joist Minimum No. 10 screws, per TableR804.3.1.1(9)

Evenly spaced, not less than 1/2″ from all edges.

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa, 1 mil = 0.0254 mm.a. Screws shall be applied through the flanges of the truss or ceiling joist or a 54 mil clip angle shall be used with two No. 10 screws in each leg. See Section R804.3.9

for additional requirements to resist uplift forces.b. Spacing of fasteners on roof sheathing panel edges applies to panel edges supported by framing members and at all roof plane perimeters. Blocking of roof sheath-

ing panel edges perpendicular to the framing members shall not be required except at the intersection of adjacent roof planes. Roof perimeter shall be supported byframing members or cold-formed blocking of the same depth and gage as the floor members.

31M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:17 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 32: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

When continuous joists are framed across interior bear-ing supports, the interior bearing supports shall be locatedwithin 24 inches (610 mm) of midspan of the ceiling joist,and the individual spans shall not exceed the applicablespans in Tables R804.3.1.1(2), R804.3.1.1(4),R804.3.1.1(6) and R804.3.1.1(8).

When the attic is to be used as an occupied space, theceiling joists shall be designed in accordance with Sec-tion R505.

R804.3.1.2 Ceiling joist bearing stiffeners. Whererequired in Tables R804.3.1.1(1) through R804.3.1.1(8),bearing stiffeners shall be installed at each bearing sup-port in accordance with Figure R804.3.1.1(2). Bearingstiffeners shall be fabricated from a C-shaped or trackmember in accordance with the one of following:

1. C-shaped bearing stiffeners shall be a minimum 33mils (0.84 mm) thick.

2. Track bearing stiffener shall be a minimum 43 mils(1.09 mm) thick.

The minimum length of a bearing stiffener shall be thedepth of member being stiffened minus 3/8 inch (9.5 mm).Each stiffener shall be fastened to the web of the ceilingjoist with a minimum of four No. 8 screws equallyspaced as shown in Figure R804.3.1.1(2). Installation ofstiffeners shall be permitted on either side of the web.

R804.3.1.3 Ceiling joist bottom flange bracing. Thebottom flanges of ceiling joists shall be laterally bracedby the application of gypsum board or continuous steelstraps installed perpendicular to the joist run in accor-dance with one of the following:

1. Gypsum board shall be fastened with No. 6 screwsin accordance with Section R702.

2. Steel straps with a minimum size of 11/2 inches ×33 mils (38 mm × 0.84 mm) shall be installed at amaximum spacing of 4 feet (1219 mm). Strapsshall be fastened to the bottom flange at each joistwith one No.8 screw and shall be fastened toblocking with two No.8 screws. Blocking shall beinstalled between joists at a maximum spacing of12 feet (3658 mm) measured along a line of contin-uous strapping (perpendicular to the joist run).Blocking shall also be located at the termination ofall straps.

R804.3.1.4 Ceiling joist top flange bracing. The topflanges of ceiling joists shall be laterally braced asrequired by Tables R804.3.1.1(1) through R804.3.1.1(8),in accordance with one of the following:

1. Minimum 33-mil (0.84 mm) C-shaped member inaccordance with Figure R804.3.1.4(1).

2. Minimum 33-mil (0.84 mm) track section inaccordance with Figure R804.3.1.4(1).

3. Minimum 33-mil (0.84 mm) hat section in accor-dance with Figure R804.3.1.4(1).

4. Minimum 54-mil (1.37 mm) 11/2 inch cold-rolledchannel section in accordance with FigureR804.3.1.4(1).

5. Minimum 11/2 inch by 33 mil (38 mm by 0.84 mm)continuous steel strap in accordance with FigureR804.3.1.4(2).

Lateral bracing shall be installed perpendicular to theceiling joists and shall be fastened to the top flange ofeach joist with one No. 8 screw. Blocking shall beinstalled between joists in line with bracing at a maxi-mum spacing of 12 feet (3658 mm) measured perpendic-ular to the joists. Ends of lateral bracing shall be attachedto blocking or anchored to a stable building componentwith two No. 8 screws.

R804.3.1.5 Ceiling joist splicing. Splices in ceilingjoists shall be permitted, if ceiling joist splices are sup-ported at interior bearing points and are constructed inaccordance with Figure R804.3.1.5. The number ofscrews on each side of the splice shall be the same asrequired for the heel joint connection in TableR804.3.1.1(9).

R804.3.2 Roof rafters. Cold-formed steel roof rafters shallbe in accordance with this section.

R804.3.2.1 Minimum roof rafter sizes. Roof rafter sizeand thickness shall be determined in accordance with thelimits set forth in Tables R804.3.2.1(1) and R804.3.2.1(2)based on the horizontal projection of the roof rafter span.For determination of roof rafter sizes, reduction of roofspans shall be permitted when a roof rafter support braceis installed in accordance with Section R804.3.2.2. Thereduced roof rafter span shall be taken as the larger of thedistance from the roof rafter support brace to the ridge orto the heel measured horizontally.

For the purpose of determining roof rafter sizes inTables R804.3.2.1(1) and R804.3.2.1(2), wind speedsshall be converted to equivalent ground snow loads inaccordance with Table R804.3.2.1(3). Roof rafter sizesshall be based on the higher of the ground snow load orthe equivalent snow load converted from the wind speed.

R804.3.2.1.1 Eave overhang. Eave overhangs shallnot exceed 24 inches (610 mm) measured horizon-tally.

R804.3.2.1.2 Rake overhangs. Rake overhangs shallnot exceed 12 inches (305 mm) measured horizon-tally. Outlookers at gable endwalls shall be installedin accordance with Figure R804.3.2.1.2.

R804.3.2.2 Roof rafter support brace. When used toreduce roof rafter spans in determining roof rafter sizes, aroof rafter support brace shall meet all of the followingconditions:

1. Minimum 350S162-33 C-shaped brace memberwith maximum length of 8 feet (2438 mm).

2. Minimum brace member slope of 45 degrees(0.785 rad) to the horizontal.

8-32 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

32M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:18 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 33: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

3. Minimum connection of brace to a roof rafter andceiling joist with four No.10 screws at each end.

4. Maximum 6 inches (152 mm) between brace/ceil-ing joist connection and load-bearing wall below.

5. Each roof rafter support brace greater than 4 feet(1219 mm) in length, shall be braced with a supple-mental brace having a minimum size of350S162-33 or 350T162-33 such that the maxi-mum unsupported length of the roof rafter supportbrace is 4 feet (1219 mm). The supplemental braceshall be continuous and shall be connected to eachroof rafter support brace using two No.8 screws.

R804.3.2.3 Roof rafter splice. Roof rafters shall not bespliced.

R804.3.2.4 Roof rafter to ceiling joist and ridge mem-ber connection. Roof rafters shall be connected to a par-allel ceiling joist to form a continuous tie betweenexterior walls in accordance with Figures R804.3.1.1(1)or R804.3.1.1(2) and Table R804.3.1.1(9). Ceiling joistsshall be connected to the top track of the load-bearingwall in accordance with Table R804.3, either with twoNo.10 screws applied through the flange of the ceilingjoist or by using a 54 mil (1.37 mm) clip angle with twoNo.10 screws in each leg. Roof rafters shall be connectedto a ridge member with a minimum 2-inch by 2-inch (51mm by 51 mm) clip angle fastened with No. 10 screws tothe ridge member in accordance with Figure R804.3.2.4and Table R804.3.2.4. The clip angle shall have a steelthickness equivalent to or greater than the roof rafterthickness and shall extend the depth of the roof raftermember to the extent possible. The ridge member shallbe fabricated from a C-shaped member and a track sec-tion, which shall have a minimum size and steel thick-ness equivalent to or greater than that of adjacent roofrafters and shall be installed in accordance with FigureR804.3.2.4.The ridge member shall extend the full depthof the sloped roof rafter cut.

R804.3.2.5 Roof rafter bottom flange bracing. Thebottom flanges of roof rafters shall be continuouslybraced, at a maximum spacing of 8 feet (2440 mm) asmeasured parallel to the roof rafters, with one of the fol-lowing members:

1. Minimum 33-mil (0.84 mm) C-shaped member.

2. Minimum 33-mil (0.84 mm) track section.

3. Minimum 11/2-inch by 33-mil (38 mm by 0.84mm) steel strap.

The bracing element shall be fastened to the bottomflange of each roof rafter with one No.8 screw andshall be fastened to blocking with two No.8 screws.Blocking shall be installed between roof raftersin-line with the continuous bracing at a maximumspacing of 12 feet (3658 mm) measured perpendicu-lar to the roof rafters. The ends of continuous bracingshall be fastened to blocking or anchored to a stablebuilding component with two No.8 screws.

R804.3.3 Hip framing. Hip framing shall consist ofjack-rafters, hip members, hip support columns and connec-tions in accordance with this section, or shall be in accor-dance with an approved design. The provisions of thissection for hip members and hip support columns shallapply only where the jack rafter slope is greater than orequal to the roof slope. For the purposes of determiningmember sizes in this section, wind speeds shall be convertedto equivalent ground snow load in accordance with TableR804.3.2.1(3).

R804.3.3.1 Jack rafters. Jack rafters shall meet therequirements for roof rafters in accordance with SectionR804.3.2, except that the requirements in SectionR804.3.2.4 shall not apply.

R804.3.3.2 Hip members. Hip members shall be fabri-cated from C-shape members and track section, whichshall have minimum sizes determined in accordance withTable R804.3.3.2. The C-shape member and track sec-tion shall be connected at a maximum spacing of 24inches (610 mm) using No. 10 screws through top andbottom flanges in accordance with Figure R804.3.2.4.The depth of the hip member shall match that of the roofrafters and jack rafters, or shall be based on an approveddesign for a beam pocket at the corner of the supportingwall.

R804.3.3.3 Hip support columns. Hip support columnsshall be used to support hip members at the ridge. A hipsupport column shall consist of a pair of C-shape mem-bers, with a minimum size determined in accordancewith Table R804.3.3.3. The C-shape members shall beconnected at a maximum spacing of 24 inches (610 mm)on center to form a box using minimum 3-inch (76 mm)× 33-mil (0.84 mm) strap connected to each of theflanges of the C-shape members with three-No. 10screws. Hip support columns shall have a continuousload path to the foundation and shall be supported at theceiling line by an interior wall or by an approved designfor a supporting element.

2009 VIRGINIA RESIDENTIAL CODE 8-33

ROOF-CEILING CONSTRUCTION

33M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:18 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 34: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-34 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

TABLE R804.3.1.1(1)CEILING JOIST SPANS

SINGLE SPANS WITH BEARING STIFFENERS10 lb per sq ft LIVE LOAD (NO ATTIC STORAGE)a, b, c 33 ksi STEEL

MEMBERDESIGNATION

ALLOWABLE SPAN (feet-inches)

Lateral Support of Top (Compression) Flange

Unbraced Mid-Span Bracing Third-Point Bracing

Ceiling Joist Spacing (inches)

16 24 16 24 16 24

350S162-33 9′-5″ 8′-6″ 12′-2″ 10′-4″ 12′-2″ 10′-7″350S162-43 10′-3″ 9′-2″ 12′-10″ 11′-2″ 12′-10″ 11′-2″350S162-54 11′-1″ 9′-11″ 13′-9″ 12′-0″ 13′-9″ 12′-0″350S162-68 12′-1″ 10′-9″ 14′-8″ 12′-10″ 14′-8″ 12′-10″350S162-97 14′-4″ 12′-7″ 16′-4″ 14′-3″ 16′-4″ 14′-3″550S162-33 10′-7″ 9′-6″ 14′-10″ 12′-10″ 15′-11″ 13′-4″550S162-43 11′-8″ 10′-6″ 16′-4″ 14′-3″ 17′-10″ 15′-3″550S162-54 12′-6″ 11′-2″ 17′-7″ 15′-7″ 19′-5″ 16′-10″550S162-68 13′-6″ 12′-1″ 19′-2″ 17′-1″ 21′-0″ 18′-4″550S162-97 15′-9″ 13′-11″ 21′-8″ 19′-3″ 23′-5″ 20′-5″800S162-33 12′-2″ 10′-11″ 17′-8″ 15′-10″ 19′-10″ 17′-1″800S162-43 13′-0″ 11′-9″ 18′-10″ 17′-0″ 21′-6″ 19′-1″800S162-54 13′-10″ 12′-5″ 20′-0″ 18′-0″ 22′-9″ 20′-4″800S162-68 14′-11″ 13′-4″ 21′-3″ 19′-1″ 24′-1″ 21′-8″800S162-97 17′-1″ 15′-2″ 23′-10″ 21′-3″ 26′-7″ 23′-10″

1000S162-43 13′-11″ 12′-6″ 20′-2″ 18′-3″ 23′-1″ 20′-9″1000S162-54 14′-9″ 13′-3″ 21′-4″ 19′-3″ 24′-4″ 22′-0″1000S162-68 15′-10″ 14′-2″ 22′-8″ 20′-5″ 25′-9″ 23′-2″1000S162-97 18′-0″ 16′-0″ 25′-3″ 22′-7″ 28′-3″ 25′-4″1200S162-43 14′-8″ 13′-3″ 21′-4″ 19′-3″ 24′-5″ 21′-8″1200S162-54 15′-7″ 14′-0″ 22′-6″ 20′-4″ 25′-9″ 23′-2″1200S162-68 16′-8″ 14′-11″ 23′-11″ 21′-6″ 27′-2″ 24′-6″1000S162-97 18′-9″ 16′-9″ 26′-6″ 23′-8″ 29′-9″ 26′-9″

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.a. Deflection criterion: L/240 for total loads.b. Ceiling dead load = 5 psf.c. Bearing stiffeners are required at all bearing points and concentrated load locations.

34M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:18 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 35: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

2009 VIRGINIA RESIDENTIAL CODE 8-35

ROOF-CEILING CONSTRUCTION

TABLE R804.3.1.1(2)CEILING JOIST SPANS

TWO EQUAL SPANS WITH BEARING STIFFENERS10 lb per sq ft LIVE LOAD (NO ATTIC STORAGE)a, b, c 33 ksi STEEL

MEMBERDESIGNATION

ALLOWABLE SPAN (feet-inches)

Lateral Support of Top (Compression) Flange

Unbraced Mid-Span Bracing Third-Point Bracing

Ceiling Joist Spacing (inches)

16 24 16 24 16 24

350S162-33 12′-11″ 10′-11″ 13′-5″ 10′-11″ 13′-5″ 10′-11″350S162-43 14′-2″ 12′-8″ 15′-10″ 12′-11″ 15′-10″ 12′-11″350S162-54 15′-6″ 13′-10″ 17′-1″ 14′-6″ 17′-9″ 14′-6″350S162-68 17′-3″ 15′-3″ 18′-6″ 16′-1″ 19′-8″ 16′-1″350S162-97 20′-10″ 18′-4″ 21′-5″ 18′-10″ 21′-11″ 18′-10″550S162-33 14′-4″ 12′-11″ 16′-7″ 14′-1″ 17′-3″ 14′-1″550S162-43 16′-0″ 14′-1″ 17′-11″ 16′-1″ 20′-7″ 16′-10″550S162-54 17′-4″ 15′-6″ 19′-5″ 17′-6″ 23′-2″ 19′-0″550S162-68 19′-1″ 16′-11″ 20′-10″ 18′-8″ 25′-2″ 21′-5″550S162-97 22′-8″ 19′-9″ 23′-6″ 20′-11″ 27′-11″ 25′-1″800S162-33 16′-5″ 14′-10″ 19′-2″ 17′-3″ 23′-1″ 18′-3″800S162-43 17′-9″ 15′-11″ 20′-6″ 18′-5″ 25′-0″ 22′-6″800S162-54 19′-1″ 17′-1″ 21′-8″ 19′-6″ 26′-4″ 23′-9″800S162-68 20′-9″ 18′-6″ 23′-1″ 20′-9″ 28′-0″ 25′-2″800S162-97 24′-5″ 21′-6″ 26′-0″ 23′-2″ 31′-1″ 27′-9″

1000S162-43 18′-11″ 17′-0″ 21′-11″ 19′-9″ 26′-8″ 24′-1″1000S162-54 20′-3″ 18′-2″ 23′-2″ 20′-10″ 28′-2″ 25′-5″1000S162-68 21′-11″ 19′-7″ 24′-7″ 22′-2″ 29′-10″ 26′-11″1000S162-97 25′-7″ 22′-7″ 27′-6″ 24′-6″ 33′-0″ 29′-7″1200S162-43 19′-11″ 17′-11″ 23′-1″ 20′-10″ 28′-3″ 25′-6″1200S162-54 21′-3″ 19′-1″ 24′-5″ 22′-0″ 29′-9″ 26′-10″1200S162-68 23′-0″ 20′-7″ 25′-11″ 23′-4″ 31′-6″ 28′-4″1000S162-97 26′-7″ 23′-6″ 28′-9″ 25′-10″ 34′-8″ 31′-1″

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.a. Deflection criterion: L/240 for total loads.b. Ceiling dead load = 5 psf.c. Bearing stiffeners are required at all bearing points and concentrated load locations.

35M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:18 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 36: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-36 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

TABLE R804.3.1.1(3)CEILING JOIST SPANS

SINGLE SPANS WITH BEARING STIFFENERS20 lb per sq ft LIVE LOAD (LIMITED ATTIC STORAGE)a, b, c 33 ksi STEEL

MEMBERDESIGNATION

ALLOWABLE SPAN (feet-inches)

Lateral Support of Top (Compression) Flange

Unbraced Mid-Span Bracing Third-Point Bracing

Ceiling Joist Spacing (inches)

16 24 16 24 16 24

350S162-33 8′-2″ 7′-2″ 9′-9″ 8′-1″ 9′-11″ 8′-1″350S162-43 8′-10″ 7′-10″ 11′-0″ 9′-5″ 11′-0″ 9′-7″350S162-54 9′-6″ 8′-6″ 11′-9″ 10′-3″ 11′-9″ 10′-3″350S162-68 10′-4″ 9′-2″ 12′-7″ 11′-0″ 12′-7″ 11′-0″350S162-97 12′-1″ 10′-8″ 14′-0″ 12′-0″ 14′-0″ 12′-0″550S162-33 9′-2″ 8′-3″ 12′-2″ 10′-2″ 12′-6″ 10′-5″550S162-43 10′-1″ 9′-1″ 13′-7″ 11′-7″ 14′-5″ 12′-2″550S162-54 10′-9″ 9′-8″ 14′-10″ 12′-10″ 15′-11″ 13′-6″550S162-68 11′-7″ 10′-4″ 16′-4″ 14′-0″ 17′-5″ 14′-11″550S162-97 13′-4″ 11′-10″ 18′-5″ 16′-2″ 20′-1″ 17′-1″800S162-33 10′-7″ 9′-6″ 15′-1″ 13′-0″ 16′-2″ 13′-7″800S162-43 11′-4″ 10′-2″ 16′-5″ 14′-6″ 18′-2″ 15′-9″800S162-54 12′-0″ 10′-9″ 17′-4″ 15′-6″ 19′-6″ 17′-0″800S162-68 12′-10″ 11′-6″ 18′-5″ 16′-6″ 20′-10″ 18′-3″800S162-97 14′-7″ 12′-11″ 20′-5″ 18′-3″ 22′-11″ 20′-5″

1000S162-43 12′-1″ 10′-11″ 17′-7″ 15′-10″ 19′-11″ 17′-3″1000S162-54 12′-10″ 11′-6″ 18′-7″ 16′-9″ 21′-2″ 18′-10″1000S162-68 13′-8″ 12′-3″ 19′-8″ 17′-8″ 22′-4″ 20′-1″1000S162-97 15′-4″ 13′-8″ 21′-8″ 19′-5″ 24′-5″ 21′-11″1200S162-43 12′-9″ 11′-6″ 18′-7″ 16′-6″ 20′-9″ 18′-2″1200S162-54 13′-6″ 12′-2″ 19′-7″ 17′-8″ 22′-5″ 20′-2″1200S162-68 14′-4″ 12′-11″ 20′-9″ 18′-8″ 23′-7″ 21′-3″1000S162-97 16′-1″ 14′-4″ 22′-10″ 20′-6″ 25′-9″ 23′-2″

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.a. Deflection criterion: L/240 for total loads.b. Ceiling dead load = 5 psf.c. Bearing stiffeners are required at all bearing points and concentrated load locations.

36M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:19 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 37: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

2009 VIRGINIA RESIDENTIAL CODE 8-37

ROOF-CEILING CONSTRUCTION

TABLE R804.3.1.1(4)CEILING JOIST SPANS

TWO EQUAL SPANS WITH BEARING STIFFENERS20 lb per sq ft LIVE LOAD (LIMITED ATTIC STORAGE)a, b, c 33 ksi STEEL

MEMBERDESIGNATION

ALLOWABLE SPAN (feet-inches)

Lateral Support of Top (Compression) Flange

Unbraced Mid-Span Bracing Third-Point Bracing

Ceiling Joist Spacing (inches)

16 24 16 24 16 24

350S162-33 10′-2″ 8′-4″ 10′-2″ 8′-4″ 10′-2″ 8′-4″350S162-43 12′-1″ 9′-10″ 12′-1″ 9′-10″ 12′-1″ 9′-10″350S162-54 13′-3″ 11′-0″ 13′-6″ 11′-0″ 13′-6″ 11′-0″350S162-68 14′-7″ 12′-3″ 15′-0″ 12′-3″ 15′-0″ 12′-3″350S162-97 17′-6″ 14′-3″ 17′-6″ 14′-3″ 17′-6″ 14′-3″550S162-33 12′-5″ 10′-9″ 13′-2″ 10′-9″ 13′-2″ 10′-9″550S162-43 13′-7″ 12′-1″ 15′-6″ 12′-9″ 15′-8″ 12′-9″550S162-54 14′-11″ 13′-4″ 16′-10″ 14′-5″ 17′-9″ 14′-5″550S162-68 16′-3″ 14′-5″ 18′-0″ 16′-1″ 20′-0″ 16′-4″550S162-97 19′-1″ 16′-10″ 20′-3″ 18′-0″ 23′-10″ 19′-5″800S162-33 14′-3″ 12′-4″ 16′-7″ 12′-4″ 16′-7″ 12′-4″800S162-43 15′-4″ 13′-10″ 17′-9″ 16′-0″ 21′-8″ 17′-9″800S162-54 16′-5″ 14′-9″ 18′-10″ 16′-11″ 22′-11″ 20′-6″800S162-68 17′-9″ 15′-11″ 20′-0″ 18′-0″ 24′-3″ 21′-10″800S162-97 20′-8″ 18′-3″ 22′-3″ 19′-11″ 26′-9″ 24′-0″

1000S162-43 16′-5″ 14′-9″ 19′-0″ 17′-2″ 23′-3″ 18′-11″1000S162-54 17′-6″ 15′-8″ 20′-1″ 18′-1″ 24′-6″ 22′-1″1000S162-68 18′-10″ 16′-10″ 21′-4″ 19′-2″ 25′-11″ 23′-4″1000S162-97 21′-8″ 19′-3″ 23′-7″ 21′-2″ 28′-5″ 25′-6″1200S162-43 17′-3″ 15′-7″ 20′-1″ 18′-2″ 24′-6″ 18′-3″1200S162-54 18′-5″ 16′-6″ 21′-3″ 19′-2″ 25′-11″ 23′-5″1200S162-68 19′-9″ 17′-8″ 22′-6″ 20′-3″ 27′-4″ 24′-8″1000S162-97 22′-7″ 20′-1″ 24′-10″ 22′-3″ 29′-11″ 26′-11″

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.a. Deflection criterion: L/240 for total loads.b. Ceiling dead load = 5 psf.c. Bearing stiffeners are required at all bearing points and concentrated load locations.

37M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:19 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 38: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-38 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

TABLE R804.3.1.1(5)CEILING JOIST SPANS

SINGLE SPANS WITHOUT BEARING STIFFENERS10 lb per sq ft LIVE LOAD (NO ATTIC STORAGE)a, b 33 ksi STEEL

MEMBERDESIGNATION

ALLOWABLE SPAN (feet-inches)

Lateral Support of Top (Compression) Flange

Unbraced Mid-Span Bracing Third-Point Bracing

Ceiling Joist Spacing (inches)

16 24 16 24 16 24

350S162-33 9′-5″ 8′-6″ 12′-2″ 10′-4″ 12′-2″ 10′-7″350S162-43 10′-3″ 9′-12″ 13′-2″ 11′-6″ 13′-2″ 11′-6″350S162-54 11′-1″ 9′-11″ 13′-9″ 12′-0″ 13′-9″ 12′-0″350S162-68 12′-1″ 10′-9″ 14′-8″ 12′-10″ 14′-8″ 12′-10″350S162-97 14′-4″ 12′-7″ 16′-10″ 14′-3″ 16′-4″ 14′-3″550S162-33 10′-7″ 9′-6″ 14′-10″ 12′-10″ 15′-11″ 13′-4″550S162-43 11′-8″ 10′-6″ 16′-4″ 14′-3″ 17′-10″ 15′-3″550S162-54 12′-6″ 11′-2″ 17′-7″ 15′-7″ 19′-5″ 16′-10″550S162-68 13′-6″ 12′-1″ 19′-2″ 17′-0″ 21′-0″ 18′-4″550S162-97 15′-9″ 13′-11″ 21′-8″ 19′-3″ 23′-5″ 20′-5″800S162-33 — — — — — —

800S162-43 13′-0″ 11′-9″ 18′-10″ 17′-0″ 21′-6″ 19′-0″800S162-54 13′-10″ 12′-5″ 20′-0″ 18′-0″ 22′-9″ 20′-4″800S162-68 14′-11″ 13′-4″ 21′-3″ 19′-1″ 24′-1″ 21′-8″800S162-97 17′-1″ 15′-2″ 23′-10″ 21′-3″ 26′-7″ 23′-10″1000S162-43 — — — — — —

1000S162-54 14′-9″ 13′-3″ 21′-4″ 19′-3″ 24′-4″ 22′-0″1000S162-68 15′-10″ 14′-2″ 22′-8″ 20′-5″ 25′-9″ 23′-2″1000S162-97 18′-0″ 16′-0″ 25′-3″ 22′-7″ 28′-3″ 25′-4″1200S162-43 — — — — — —

1200S162-54 — — — — — —

1200S162-68 16′-8″ 14′-11″ 23′-11″ 21′-6″ 27′-2″ 24′-6″1000S162-97 18′-9″ 16′-9″ 26′-6″ 23′-8″ 29′-9″ 26′-9″

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.a. Deflection criterion: L/240 for total loads.b. Ceiling dead load = 5 psf.

38M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:20 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 39: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

2009 VIRGINIA RESIDENTIAL CODE 8-39

ROOF-CEILING CONSTRUCTION

TABLE R804.3.1.1(6)CEILING JOIST SPANS

TWO EQUAL SPANS WITHOUT BEARING STIFFENERS10 lb per sq ft LIVE LOAD (NO ATTIC STORAGE)a, b 33 ksi STEEL

MEMBERDESIGNATION

ALLOWABLE SPAN (feet-inches)

Lateral Support of Top (Compression) Flange

Unbraced Mid-Span Bracing Third-Point Bracing

Ceiling Joist Spacing (inches)

16 24 16 24 16 24

350S162-33 11′-9″ 8′-11″ 11′-9″ 8′-11″ 11′-9″ 8′-11″350S162-43 14′-2″ 11′-7″ 14′-11″ 11′-7″ 14′-11″ 11′-7″350S162-54 15′-6″ 13′-10″ 17′-1″ 13′-10″ 17′-7″ 13′-10″350S162-68 17′-3″ 15′-3″ 18′-6″ 16′-1″ 19′-8″ 16′-1″350S162-97 20′-10″ 18′-4″ 21′-5″ 18′-9″ 21′-11″ 18′-9″550S162-33 13′-4″ 9′-11″ 13′-4″ 9′-11″ 13′-4″ 9′-11″550S162-43 16′-0″ 13′-6″ 17′-9″ 13′-6″ 17′-9″ 13′-6″550S162-54 17′-4″ 15′-6″ 19′-5″ 16′-10″ 21′-9″ 16′-10″550S162-68 19′-1″ 16′-11″ 20′-10″ 18′-8″ 24′-11″ 20′-6″550S162-97 22′-8″ 20′-0″ 23′-9″ 21′-1″ 28′-2″ 25′-1″800S162-33 — — — — — —

800S162-43 17′-9″ 15′-7″ 20′-6″ 15′-7″ 21′-0″ 15′-7″800S162-54 19′-1″ 17′-1″ 21′-8″ 19′-6″ 26′-4″ 23′-10″800S162-68 20′-9″ 18′-6″ 23′-1″ 20′-9″ 28′-0″ 25′-2″800S162-97 24′-5″ 21′-6″ 26′-0″ 23′-2″ 31′-1″ 27′-9″

1000S162-43 — — — — — —

1000S162-54 20′-3″ 18′-2″ 23′-2″ 20′-10″ 28′-2″ 21′-2″1000S162-68 21′-11″ 19′-7″ 24′-7″ 22′-2″ 29′-10″ 26′-11″1000S162-97 25′-7″ 22′-7″ 27′-6″ 24′-6″ 33′-0″ 29′-7″1200S162-43 — — — — — —

1200S162-54 — — — — — —

1200S162-68 23′-0″ 20′-7″ 25′-11″ 23′-4″ 31′-6″ 28′-4″1000S162-97 26′-7″ 23′-6″ 28′-9″ 25′-10″ 34′-8″ 31′-1″

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.a. Deflection criterion: L/240 for total loads.b. Ceiling dead load = 5 psf.

39M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:20 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 40: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-40 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

TABLE R804.3.1.1(7)CEILING JOIST SPANS

SINGLE SPANS WITHOUT BEARING STIFFENERS20 lb per sq ft LIVE LOAD (LIMITED ATTIC STORAGE)a, b 33 ksi STEEL

MEMBERDESIGNATION

ALLOWABLE SPAN (feet-inches)

Lateral Support of Top (Compression) Flange

Unbraced Mid-Span Bracing Third-Point Bracing

Ceiling Joist Spacing (inches)

16 24 16 24 16 24

350S162-33 8′-2″ 6′-10″ 9′-9″ 6′-10″ 9′-11″ 6′-10″350S162-43 8′-10″ 7′-10″ 11′-0″ 9′-5″ 11′-0″ 9′-7″350S162-54 9′-6″ 8′-6″ 11′-9″ 10′-3″ 11′-9″ 10′-3″350S162-68 10′-4″ 9′-2″ 12′-7″ 11′-0″ 12′-7″ 11′-0″350S162-97 12′-10″ 10′-8″ 13′-9″ 12′-0″ 13′-9″ 12′-0″550S162-33 9′-2″ 8′-3″ 12′-2″ 8′-5″ 12′-6″ 8′-5″550S162-43 10′-1″ 9′-1″ 13′-7″ 11′-8″ 14′-5″ 12′-2″550S162-54 10′-9″ 9′-8″ 14′-10″ 12′-10″ 15′-11″ 13′-6″550S162-68 11′-7″ 10′-4″ 16′-4″ 14′-0″ 17′-5″ 14′-11″550S162-97 13′-4″ 11′-10″ 18′-5″ 16′-2″ 20′-1″ 17′-4″800S162-33 — — — — — —

800S162-43 11′-4″ 10′-1″ 16′-5″ 13′-6″ 18′-1″ 13′-6″800S162-54 20′-0″ 10′-9″ 17′-4″ 15′-6″ 19′-6″ 27′-0″800S162-68 12′-10″ 11′-6″ 18′-5″ 16′-6″ 20′-10″ 18′-3″800S162-97 14′-7″ 12′-11″ 20′-5″ 18′-3″ 22′-11″ 20′-5″

1000S162-43 — — — — — —

1000S162-54 12′-10″ 11′-6″ 18′-7″ 16′-9″ 21′-2″ 15′-5″1000S162-68 13′-8″ 12′-3″ 19′-8″ 17′-8″ 22′-4″ 20′-1″1000S162-97 15′-4″ 13′-8″ 21′-8″ 19′-5″ 24′-5″ 21′-11″1200S162-43 — — — — — —

1200S162-54 — — — — — —

1200S162-68 14′-4″ 12′-11″ 20′-9″ 18′-8″ 23′-7″ 21′-3″1000S162-97 16′-1″ 14′-4″ 22′-10″ 20′-6″ 25′-9″ 23′-2″

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.a. Deflection criterion: L/240 for total loads.b. Ceiling dead load = 5 psf.

40M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:21 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 41: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

2009 VIRGINIA RESIDENTIAL CODE 8-41

ROOF-CEILING CONSTRUCTION

TABLE R804.3.1.1(8)CEILING JOIST SPANS

TWO EQUAL SPANS WITHOUT BEARING STIFFENERS20 lb per sq ft LIVE LOAD (LIMITED ATTIC STORAGE)a, b 33 ksi STEEL

MEMBERDESIGNATION

ALLOWABLE SPAN (feet-inches)

Lateral Support of Top (Compression) Flange

Unbraced Mid-Span Bracing Third-Point Bracing

Ceiling Joist Spacing (inches)

16 24 16 24 16 24

350S162-33 8′-1″ 6′-1″ 8′-1″ 6′-1″ 8′-1″ 6′-1″350S162-43 10′-7″ 8′-1″ 10′-7″ 8′-1″ 10′-7″ 8′-1″350S162-54 12′-8″ 9′-10″ 12′-8″ 9′-10″ 12′-8″ 9′-10″350S162-68 14′-7″ 11′-10″ 14′-11″ 11′-10″ 14′-11″ 11′-10″350S162-97 17′-6″ 14′-3″ 17′-6″ 14′-3″ 17′-6″ 14′-3″550S162-33 8′-11″ 6′-8″ 8′-11″ 6′-8″ 8′-11″ 6′-8″550S162-43 12′-3″ 9′-2″ 12′-3″ 9′-2″ 12′-3″ 9′-2″550S162-54 14′-11″ 11′-8″ 15′-4″ 11′-8″ 15′-4″ 11′-8″550S162-68 16′-3″ 14′-5″ 18′-0″ 15′-8″ 18′-10″ 14′-7″550S162-97 19′-1″ 16′-10″ 20′-3″ 18′-0″ 23′-9″ 19′-5″800S162-33 — — — — — —

800S162-43 13′-11″ 9′-10″ 13′-11″ 9′-10″ 13′-11″ 9′-10″800S162-54 16′-5″ 13′-9″ 18′-8″ 13′-9″ 18′-8″ 13′-9″800S162-68 17′-9″ 15′-11″ 20′-0″ 18′-0″ 24′-1″ 18′-3″800S162-97 20′-8″ 18′-3″ 22′-3″ 19′-11″ 26′-9″ 24′-0″

1000S162-43 — — — — — —

1000S162-54 17′-6″ 13′-11″ 19′-1″ 13′-11″ 19′-1″ 13′-11″1000S162-68 18′-10″ 16′-10″ 21′-4″ 19′-2″ 25′-11″ 19′-7″1000S162-97 21′-8″ 19′-3″ 23′-7″ 21′-2″ 28′-5″ 25′-6″1200S162-43 — — — — — —

1200S162-54 — — — — — —

1200S162-68 19′-9″ 17′-8″ 22′-6″ 19′-8″ 26′-8″ 19′-8″1000S162-97 22′-7″ 20′-1″ 24′-10″ 22′-3″ 29′-11″ 26′-11″

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.a. Deflection criterion: L/240 for total loads.b. Ceiling dead load = 5 psf.

41M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:21 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 42: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-42 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

TABLE R804.3.1.1(9)NUMBER OF SCREWS REQUIRED FOR CEILING JOIST TO ROOF RAFTER CONNECTIONa

ROOFSLOPE

NUMBER OF SCREWS

Building width (feet)

24 28 32 36 40

Ground snow load (psf)

20 30 50 70 20 30 50 70 20 30 50 70 20 30 50 70 20 30 50 70

3/12 5 6 9 11 5 7 10 13 6 8 11 15 7 8 13 17 8 9 14 19

4/12 4 5 7 9 4 5 8 10 5 6 9 12 5 7 10 13 6 7 11 14

5/12 3 4 6 7 4 4 6 8 4 5 7 10 5 5 8 11 5 6 9 12

6/12 3 3 5 6 3 4 6 7 4 4 6 8 4 5 7 9 4 5 8 10

7/12 3 3 4 6 3 3 5 7 3 4 6 7 4 4 6 8 4 5 7 9

8/12 2 3 4 5 3 3 5 6 3 4 5 7 3 4 6 8 4 4 6 8

9/12 2 3 4 5 3 3 4 6 3 3 5 6 3 4 5 7 3 4 6 8

10/12 2 2 4 5 2 3 4 5 3 3 5 6 3 3 5 7 3 4 6 7

11/12 2 2 3 4 2 3 4 5 3 3 4 6 3 3 5 6 3 4 5 7

12/12 2 2 3 4 2 3 4 5 2 3 4 5 3 3 5 6 3 4 5 7

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.a. Screws shall be No. 10.

CEILING JOIST

RAFTER

TRACK

FASTEN RAFTER TOCEILING JOIST WITHMINIMUM NO. 10 SCREWSAS REQUIRED OR THROUGHCLIP ANGLE, PLATE OR OTHERAPPROVED CONNECTOR

LOAD BEARING STUD

FASTEN ROOF TO WALLTRACK WITH 2-NO. 10SCREWS THROUGH CEILINGJOIST FLANGES, 54 MIL CLIPANGLE (MINIMUM), STEELPLATE OR OTHERAPPROVED CONNECTOR

For SI: 1 mil = 0.0254 mm.

FIGURE R804.3.1.1(1)JOIST TO RAFTER CONNECTION

42M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:23 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 43: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

2009 VIRGINIA RESIDENTIAL CODE 8-43

ROOF-CEILING CONSTRUCTION

ANCHORAGE ATEND IS REQUIRED.

BRACING. USE 1 NO. 8 SCREW TO EACH JOIST.

AT SPLICE LOCATIONS, EITHER LAP MEMBERSAS SHOWN OR ABUT, WITH 2 NO. 8 SCREWSEACH END OF EACH MEMBER.

CEILING FRAMINGMEMBERS. GYPSUM BOARDON BOTTOM CHORD NOTSHOWN FOR CLARITY.

FIGURE R804.3.1.4(1)CEILING JOIST TOP FLANGE BRACING WITH C-SHAPE, TRACK OR COLD-ROLLED CHANNEL

RAFTER

4 NO. 10 SCREWS, EVENLYSPACED, THROUGH WEBSTEFFENER AND CEILINGJOIST. (SCREWS PENETRATINGRAFTER AND CEILING JOISTMEMBERS MAY COUNTTOWARD HEEL JOISTCONNECTION REQUIREMENTS)

LOAD BEARING STUD

BEARINGSTIFFENER

CEILINGJOIST

TRACK

FIGURE R804.3.1.1(2)BEARING STIFFENER

43M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:24 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 44: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-44 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

C-SHAPE OR TRACKSECTION WITHMINIMUM SIZE ANDTHICKNESS ASCEILING JOIST

CEILING JOIST

CEILING JOIST

NUMBER OF SCREWSON EACH SIDE OFSPLICE SHALL BE THESAME AS REQUIREDFOR THE HEEL JOINTCONNECTION

TRACK

LOAD BEARING STUD

6 IN. MIN3 IN. MIN.

For SI: 1 inch = 25.4 mm.

FIGURE R804.3.1.5SPLICED CEILING JOISTS

ANCHORAGE ATEND IS REQUIRED.

STRAP BRACING, INSTALL TAUT,USE 1 NO. 8 SCREW TO EACH JOIST.

SHORT SEGMENT OFSTUD OR TRACKUSED AS BLOCKING:AT STRAP SPLICELOCATIONS, AT ENDS,AND AT MAX. 12 FT O.C.

For SI: 1 foot = 304.8 mm.

FIGURE R804.3.1.4(2)CEILING JOIST TOP FLANGE BRACING WITH CONTINUOUS STEEL STRAP AND BLOCKING

44M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:26 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 45: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

2009 VIRGINIA RESIDENTIAL CODE 8-45

ROOF-CEILING CONSTRUCTION

TABLE R804.3.2.1(1)ROOF RAFTER SPANSa, b, c

33 ksi STEEL

MEMBERDESIGNATION

ALLOWABLE SPAN MEASURED HORIZONTALLY (feet-inches)

Ground snow load (psf)

20 30 50 70

Rafter spacing (inches)

16 24 16 24 16 24 16 24

550S162-33 14′-0″ 11′-6″ 11′-11″ 9′-7″ 9′-6″ 7′-9″ 8′-2″ 6′-8″

550S162-43 16′-8″ 13′-11″ 14′-5″ 11′-9″ 11′-6″ 9′-5″ 9′-10″ 8′-0″

550S162-54 17′-11″ 15′-7″ 15′-7″ 13′-3″ 12′-11″ 10′-7″ 11′-1″ 9′-1″

550S162-68 19′-2″ 16′-9″ 16′-9″ 14′-7″ 14′-1″ 11′-10″ 12′-6″ 10′-2″

550S162-97 21′-3″ 18′-6″ 18′-6″ 16′-2″ 15′-8″ 13′-8″ 14′-0″ 12′-2″

800S162-33 16′-5″ 13′-5″ 13′-11″ 11′-4″ 11′-1″ 8′-2″ 9′-0″ 6′-0″

800S162-43 19′-9″ 16′-1″ 16′-8″ 13′-7″ 13′-4″ 10′-10″ 11′-5″ 9′-4″

800S162-54 22′-8″ 18′-6″ 19′-2″ 15′-8″ 15′-4″ 12′-6″ 13′-1″ 10′-8″

800S162-68 25′-10″ 21′-2″ 21′-11″ 17′-10″ 17′-6″ 14′-4″ 15′-0″ 12′-3″

800S162-97 21′-3″ 18′-6″ 18′-6″ 16′-2″ 15′-8″ 13′-8″ 14′-0″ 12′-2″

1000S162-43 22′-3″ 18′-2″ 18′-9″ 15′-8″ 15′-0″ 12′-3″ 12′-10″ 10′-6″

1000S162-54 25′-8″ 20′-11″ 21′-8″ 17′-9″ 17′-4″ 14′-2″ 14′-10″ 12′-1″

1000S162-68 29′-7″ 24′-2″ 25′-0″ 20′-5″ 20′-0″ 16′-4″ 17′-2″ 14′-0″

1000S162-97 34′-8″ 30′-4″ 30′-4″ 25′-10″ 25′-3″ 20′-8″ 21′-8″ 17′-8″

1200S162-54 28′-3″ 23′-1″ 23′-11″ 19′-7″ 19′-2″ 15′-7″ 16′-5″ 13′-5″

1200S162-68 32′-10″ 26′-10″ 27′-9″ 22′-8″ 22′-2″ 18′-1″ 19′-0″ 15′-6″

1200S162-97 40′-6″ 33′-5″ 34′-6″ 28′-3″ 27′-7″ 22′-7″ 23′-8″ 19′-4″

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.a. Table provides maximum horizontal rafter spans in feet and inches for slopes between 3:12 and 12:12.b. Deflection criterion: L/240 for live loads and L/180 for total loads.c. Roof dead load = 12 psf.

45M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:26 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 46: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-46 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

TABLE R804.3.2.1(2)ROOF RAFTER SPANSa, b, c

50 ksi STEEL

MEMBERDESIGNATION

ALLOWABLE SPAN MEASURED HORIZONTALLY (feet-inches)

Equivalent ground snow load (psf)

20 30 50 70

Rafter spacing (inches)

16 24 16 24 16 24 16 24

550S162-33 15′-4″ 12′-11″ 13′-4″ 10′′-11″ 10′-9″ 8′-9″ 9′-2″ 7′-6″

550S162-43 16′-8″ 14′-7″ 14′-7″ 12′-9″ 12′-3″ 10′-6″ 11′-0″ 9′-0″

550S162-54 17′-11″ 15′-7″ 15′-7″ 13′-8″ 13′-2″ 11′-6″ 11′-9″ 10′-3″

550S162-68 19′-2″ 16′-9″ 16′-9″ 14′-7″ 14′-1″ 12′-4″ 12′-7″ 11′-0″

550S162-97 21′-3″ 18′-6″ 18′-6″ 16′-2″ 15′-8″ 13′-8″ 14′-0″ 12′-3″

800S162-33 18′-10″ 15′-5″ 15′-11″ 12′-9″ 12′-3″ 8′-2″ 9′-0″ 6′-0″

800S162-43 22′-3″ 18′-2″ 18′-10″ 15′-5″ 15′-1″ 12′-3″ 12′-11″ 10′-6″

800S162-54 24′-2″ 21′-2″ 21′-1″ 18′-5″ 17′-10″ 14′-8″ 15′-5″ 12′-7″

800S162-68 25′-11″ 22′-8″ 22′-8″ 19′-9″ 19′-1″ 16′-8″ 17′-1″ 14′-9″

800S162-97 28′-10″ 25′-2″ 25′-2″ 22′-0″ 21′-2″ 18′-6″ 19′-0″ 16′-7″

1000S162-43 25′-2″ 20′-7″ 21′-4″ 17′-5″ 17′-0″ 13′-11″ 14′-7″ 10′ − 7″

1000S162-54 29′-0″ 24′-6″ 25′-4″ 20′-9″ 20′-3″ 16′-7″ 17′-5″ 14′-2″

1000S162-68 31′-2″ 27′-3″ 27′-3″ 23′-9″ 20′-0″ 19′-6″ 20′-6″ 16′-8″

1000S162-97 34′-8″ 30′-4″ 30′-4″ 26′-5″ 25′-7″ 22′-4″ 22′-10″ 20′-0″

1200S162-54 33′-2″ 27′-1″ 28′-1″ 22′-11″ 22′-5″ 18′-4″ 19′-3″ 15′-8″

1200S162-68 36′- 4″ 31′-9″ 31′-9″ 27′-0″ 26′-5″ 21′-6″ 22′-6″ 18′-6″

1200S162-97 40′-6″ 35′-4″ 35′-4″ 30′-11″ 29′-10″ 26′-1″ 26′-8″ 23′-1″

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.a. Table provides maximum horizontal rafter spans in feet and inches for slopes between 3:12 and 12:12.b. Deflection criterion: L/240 for live loads and L/180 for total loads.c. Roof dead load = 12 psf.

46M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:26 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 47: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

2009 VIRGINIA RESIDENTIAL CODE 8-47

ROOF-CEILING CONSTRUCTION

TABLE R804.3.2.1(3)BASIC WIND SPEED TO EQUIVALENT SNOW LOAD CONVERSION

BASIC WIND SPEEDAND EXPOSURE

EQUIVALENT GROUND SNOW LOAD (psf)

Roof slope

Exp. B Exp. C 3:12 4:12 5:12 6:12 7:12 8:12 9:12 10:12 11:12 12:12

85 mph — 20 20 20 20 20 20 30 30 30 30

100 mph 85 mph 20 20 20 20 30 30 30 30 50 50

110 mph 100 mph 20 20 20 20 30 50 50 50 50 50

— 110 mph 30 30 30 50 50 50 70 70 70 —

For SI: 1 mile per hour = 0.447 m/s, 1 pound per square foot = 0.0479 kPa.

OPTION #1

350S 162-33 BLOCKINGBETWEEN OUTLOOKERSWITH #8 SCREWS @ 6 IN.0.C. TO WALL TRACK(MIN. 3 SCREWS EACH)

1 FT MAX 1 FT MIN

#8 SCREWS @ 6 IN. O.C.

#8 SCREWS@ 6 IN. O.C.

CLIP ANGLEWITH 2 - #8SCREWS EACHLEG

ROOF RAFTER

350S162-33 (WITH0 WEB HOLES)OUTLOOK RAFTERSALIGN WITH EACHGABLE WALL STUD

4 - #8 SCREWS(OUTLOOKER TOWALL TRACK)

WALL SHEATHING

GABLE ENDWALL STUDS OPTION #2

1 FT MAX(SEE NOTE)

1 FT MIN

#8 SCREWS @ 6 IN. O.C.

ROOF RAFTER

NOTE: ROOF SHEATHING JOINTS PARALLELTO THE GABLE ENDWALL ARE NOT PERMITTEDIN THIS REGION UNLESS ANTENSION TIE IS PROVIDED.

APPROVED

350S 162-33 OUTLOOKERS@ 2 FT O.C. WITHCONTINUOUSTRACK EACH END

2 - #8 SCREWSTO EACH STUD

WALL SHEATHING

GABLE ENDWALL STUDS

FIGURE R804.3.2.1.2GABLE ENDWALL OVERHANG DETAILS

47M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:28 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 48: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

R804.3.3.4 Hip framing connections. Hip rafter framingconnections shall be installed in accordance with the fol-lowing:

1. Jack rafters shall be connected at the eave to a paral-lel C-shape blocking member in accordance withFigure R804.3.3.4(1). The C-shape blocking mem-ber shall be attached to the supporting wall trackwith minimum two No. 10 screws.

2. Jack rafters shall be connected to a hip member witha minimum 2 inch × 2 inch (51 mm × 51 mm) clipangle fastened with No. 10 screws to the hip memberin accordance with Figure R804.3.2.4 and TableR804.3.2.4. The clip angle shall have a steel thick-ness equivalent to or greater than the jack rafterthickness and shall extend the depth of the jack raftermember to the extent possible.

3. The connection of the hip support columns at theceiling line shall be in accordance with FigureR804.3.3.4(2), with an uplift strap sized in accor-dance with Table R804.3.3.4(1).

4. The connection of hip support members, ridge mem-bers and hip support columns at the ridge shall be in

accordance with Figures R804.3.3.4(3) andR804.3.3.4(4) and Table R804.3.3.4(2).

5. The connection of hip members to the wall cornershall be in accordance with Figure R804.3.3.4(5)and Table R804.3.3.4(3).

R804.3.4 Cutting and notching. Flanges and lips of load-bearing cold-formed steel roof framing members shall notbe cut or notched.

R804.3.5 Headers. Roof-ceiling framing above wall openingsshall be supported on headers. The allowable spans for headersin load-bearing walls shall not exceed the values set forth inSection R603.6 and Tables R603.6(1) through R603.6(24).

R804.3.6 Framing of openings in roofs and ceilings. Open-ings in roofs and ceilings shall be framed with header and trim-mer joists. Header joist spans shall not exceed 4 feet (1219 mm)in length. Header and trimmer joists shall be fabricated fromjoist and track members having a minimum size and thickness atleast equivalent to the adjacent ceiling joists or roof rafters andshall be installed in accordance with Figures R804.3.6(1) andR804.3.6(2). Each header joist shall be connected to trimmerjoists with a minimum of four 2-inch by 2-inch (51 by 51 mm)clip angles. Each clip angle shall be fastened to both the header

8-48 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

CLIP ANGLE

RAFTER(TYP.)

NO. 10 SCREWS IN EACHLEG OF CLIP ANGLE

HIP MEMBER OR RIDGEMEMBER: C-SHAPE INSIDEA TRACK SECTION FASTENEDWITH NO. 10 SCREWS AT 24 IN.O.C. THROUGH TOP ANDBOTTOM FLANGES

FIGURE R804.3.2.4HIP MEMBER OR RIDGE MEMBER CONNECTION

TABLE R804.3.2.4SCREWS REQUIRED AT EACH LEG OF CLIP ANGLE FOR HIP RAFTER

TO HIP MEMBER OR ROOF RAFTER TO RIDGE MEMBER CONNECTIONa

BUILDING WIDTH(feet)

NUMBER OF SCREWS

Ground snow load (psf)

0 to 20 21 to 30 31 to 50 51 to 70

24 2 2 3 4

28 2 3 4 5

32 2 3 4 5

36 3 3 5 6

40 3 4 5 7

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.a. Screws shall be No. 10 minimum.

48M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:29 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 49: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

and trimmer joists with four No. 8 screws, evenly spaced,through each leg of the clip angle. The steel thickness of the clipangles shall be not less than that of the ceiling joist or roof rafter.Each track section for a built-up header or trimmer joist shallextend the full length of the joist (continuous).

R804.3.7 Roof trusses. Cold-formed steel trusses shall bedesigned and installed in accordance with AISI S100, Sec-tion D4. Trusses shall be connected to the top track of theload-bearing wall in accordance with Table R804.3, eitherwith two No.10 screws applied through the flange of thetruss or by using a 54 mil (1.37 mm) clip angle with twoNo.10 screws in each leg.

R804.3.8 Ceiling and roof diaphragms. Ceiling and roofdiaphragms shall be in accordance with this section.

R804.3.8.1 Ceiling diaphragm. At gable endwalls a ceil-ing diaphragm shall be provided by attaching a minimum1/2-inch (12.7 mm) gypsum board in accordance withTables R804.3.8(1) and R804.3.8(2) or a minimum3/8-inch (9.5 mm) wood structural panel sheathing, whichcomplies with Section R803, in accordance with TableR804.3.8(3) to the bottom of ceiling joists or roof trussesand connected to wall framing in accordance with FiguresR804.3.8(1) and R804.3.8(2), unless studs are designed asfull height without bracing at the ceiling. Flat blockingshall consist of C-shape or track section with a minimumthickness of 33 mils (0.84 mm).

The ceiling diaphragm shall be secured with screwsspaced at a maximum 6 inches (152 mm) o.c. at panel edgesand a maximum 12 inches (305 mm) o.c. in the field. Multi-plying the required lengths in Tables R804.3.8(1) andR804.3.8(2) for gypsum board sheathed ceiling dia-phragms shall be permitted to be multiplied by 0.35 shall bepermitted if all panel edges are blocked. Multiplying therequired lengths in Tables R804.3.8(1) and R804.3.8(2) forgypsum board sheathed ceiling diaphragms by 0.9 shall bepermitted if all panel edges are secured with screws spacedat 4 inches (102 mm) o.c.

R804.3.8.2 Roof diaphragm. A roof diaphragm shallbe provided by attaching a minimum of 3/8 inch (9.5 mm)wood structural panel which complies with SectionR803 to roof rafters or truss top chords in accordancewith Table R804.3. Buildings with 3:1 or larger planaspect ratio and with roof rafter slope (pitch) of 9:12 orlarger shall have the roof rafters and ceiling joistsblocked in accordance with Figure R804.3.8(3).

R804.3.9 Roof tie-down. Roof assemblies subject to winduplift pressures of 20 pounds per square foot (0.96 kPa) orgreater, as established in Table R301.2(2), shall have raf-ter-to-bearing wall ties provided in accordance with TableR802.11.

2009 VIRGINIA RESIDENTIAL CODE 8-49

ROOF-CEILING CONSTRUCTION

TABLE R804.3.3.3HIP SUPPORT COLUMN SIZES

BUILDING WIDTH(feet)

HIP SUPPORT COLUMN DESIGNATIONa, b

Equivalent ground snow load (psf)

0 to 20 21 to 30 31 to 50 51 to 70

24 2-350S162-33 2-350S162-33 2-350S162-43 2-350S162-54

28 2-350S162-54 2-550S162-54 2-550S162-68 2-550S162-68

32 2-550S162-68 2-550S162-68 2-550S162-97 —

36 2-550S162-97 — — —

40 — — — —

For SI: 1 foot = 304,8 mm, 1 pound per square foot = 0.0479 kPa.a. Box shape column only in accordance with Figure R804.3.3.4(2).b. 33 ksi steel for 33 and 43 mil material; 50 ksi steel for thicker material.

TABLE R804.3.3.2HIP MEMBER SIZES, 33 ksi STEEL

BUILDING WIDTH(feet)

HIP MEMBER DESIGNATIONa

Equivalent ground snow load (psf)

0 to 20 21 to 30 31 to 50 51 to 70

24800S162-68800T150-68

800S162-68800T150-68

800S162-97800T150-97

1000S162-971000T150-97

281000S162-681000T150-68

1000S162-681000T150-68

1000S162-971000T150-97

1200S162-971200T150-97

321000S162-971000T150-97

1000S162-971000T150-97

1200S162-971200T150-97

361200S162-971200T150-97

— — —

40 — — — —

For SI: 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.a. The web depth of the roof rafters and jack rafters is to match at the hip or they shall be installed in accordance with an approved design.

49M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:29 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 50: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-50 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

TABLE R804.3.3.4(1)UPLIFT STRAP CONNECTION REQUIREMENTS

HIP SUPPORT COLUMN AT CEILING LINE

BUILDING WIDTH(feet)

BASIC WIND SPEED (mph) EXPOSURE B

85 100 110 — —

BASIC WIND SPEED (mph) EXPOSURE C

— 85 — 100 110

Number of No. 10 screws in each end of each 3 inch by 54-mil steel strapa, b, c

24 3 4 4 6 7

28 4 6 6 8 10

32 5 8 8 11 13

36 7 10 11 14 17

40 — — — — —

For SI: 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa, 1 mil = 0.0254 mm.a. Two straps are required, one each side of the column.b. Space screws at 3/4 inch on-center and provide 3/4 inch end distance.c. 50 ksi steel strap.

CEILING JOISTTYP.

JACK RAFTERTYP.

CONNECTION OF BLOCKING TOJOIST W/ CLIP ANGLE OR BENT WEBOF BLOCKING W/2–#8 SCREWS

WALL STUDTYP.

SHEATHINGTYP.

TYP. ROOF BLOCKINGDETAIL AND HOLDOWN

4–#10 SCREWSEVENLY SPACED

C-SECTION BLOCKING ATEACH JACK RAFTERSAME MEMBER AS CEILING JOIST.

FIGURE R804.3.3.4(1)JACK RAFTER CONNECTION AT EAVE

50M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:29 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 51: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

2009 VIRGINIA RESIDENTIAL CODE 8-51

ROOF-CEILING CONSTRUCTION

3 IN. x 33 MIL STRAP EACHSIDE W/3–#10 SCREWSTO EACH C-SECTIONSPACED AT 24 IN. O.C. FORFULL HEIGHT OF COLUMN

HIP SUPPORT COLUMN

TRACK SECTION BETWEENCEILING JOISTS, FASTENW/4–#10 SCREWS TO TOPTRACK OF WALL BELOW

WALL TRACK

3 IN. x 54 MIL STRAP EACHSIDE W/#10 SCREWS

CEILING JOIST

INTERIOR WALL STUD

HIP SUPPORT COLUMNCONTINUING TOFOUNDATION OR TOPOF WALL BELOW

For SI: 1 inch = 25.4 mm, 1 mil = 0.0254 mm.

FIGURE R804.3.3.4(2)HIP SUPPORT COLUMN

TABLE R804.3.3.4(2)CONNECTION REQUIREMENTS

HIP MEMBER TO HIP SUPPORT COLUMN

BUILDING WIDTH(feet)

NUMBER OF NO. 10 SCREWS IN EACH FRAMING ANGLEa, b, c

Equivalent ground snow load (psf)

0 to 20 21 to 30 31 to 50 51 to 70

24 10 10 10 12

28 10 10 14 18

32 10 12 — —

36 14 — — —

40 — — — —

For SI: 1 foot = 304.8 mm, 1 pound per square foot = 0.0479kPa.a. Screws to be divided equally between the connection to the hip member and the column. Refer to Figures R804.3.3.4(3) and R804.3.3.4(4).b. The number of screws required in each framing angle is not to be less than shown in Table R804.3.3.4(1).c. 50 ksi steel from the framing angle.

51M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:29 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 52: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-52 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

CONNECTIONSRIDGE MEMBER

HIP MEMBER

HIP SUPPORT COLUMNHOLD TOP OF COLUMNBELOW ROOF SHEATHING

FIGURE R804.3.3.4(3)HIP CONNECTIONS AT RIDGE

TABLE R804.3.3.4(3)UPLIFT STRAP CONNECTION REQUIREMENTS

HIP MEMBER TO WALL

BUILDING WIDTH(feet)

BASIC WIND SPEED (mph) EXPOSURE B

85 100 110 — —

BASIC WIND SPEED (mph) EXPOSURE C

— 85 — 100 110

Number of No. 10 screws in each end of each 3 inch by 54-mil Steel strapa, b, c

24 2 2 3 3 4

28 2 3 3 4 5

32 3 4 4 6 7

36 3 5 5 7 8

40 — — — — —

For SI: 1 foot = 304.8 mm, 1 pound per square foot = 0.0479kPa.a. Two straps are required, one each side of the column.b. Space screws at 3/4 inches on-center and provide 3/4 inch end distance.c. 50 ksi steel strap.

52M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:29 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 53: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

2009 VIRGINIA RESIDENTIAL CODE 8-53

ROOF-CEILING CONSTRUCTION

CONNECTION @ 3½ BOX COLUMN″

CONNECTION @ 5½ BOX COLUMN″

C

C

C

WORK POINT &BOX COLUMN

WORK POINT &OUTSIDE FACE OFHIP MEMBER

WORK POINT &OUTSIDE FACE OFHIP MEMBER

HIP MEMBERTYP. 2 PLACES

BENT 54 MILCONNECTION P

54 MIL CLIP ANGLE

RE

Q’D

WORK POINT

MIN. OF 3—#10SCREWS @EA. LOCATION

BENT 54 MILCONNECTION P

RIDGE MEMBER

BOX COLUMN

54 MIL CLIP ANGLE

NOTE: RAFTERS NOT SHOWN FOR CLARITY

L

L

1½″

1½″

2″

2″3″

3″

3″

3″

C

C

C

WORK POINT &OUTSIDE FACE OFHIP MEMBER

WORK POINT &BOX COLUMN

54 MIL CLIP ANGLE

WORK POINT

WORK POINT &OUTSIDE FACE OFHIP MEMBER

HIP MEMBERTYP. 2 PLACES

BENT 54 MILCONNECTION P

MIN. OF 3—#10SCREWS @EA. LOCATION

BENT 54 MILCONNECTION P

RIDGE MEMBER

BOX COLUMN

54 MIL CLIP ANGLE

NOTE: RAFTERS NOT SHOWN FOR CLARITY

L

L

1½″

1½″

2″

2″

3″

3″

3″

For SI: 1 inch = 25.4 mm, 1 mil = 0.0254 mm.

FIGURE R804.3.3.4(4)HIP CONNECTIONS AT RIDGE AND BOX COLUMN

53M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:29 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 54: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-54 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

For SI: 1 foot = 304.8 mm.

FIGURE R804.3.6(1)ROOF OR CEILING OPENING

HIP MEMBERWEB STIFFENERS(MATCH WALL STUDS)EACH SIDE W/6 —#10 SCREWSTOP TRACK W/2 —#10 SCREWS

WALL TOP TRACKTYP.

UPLIFT STRAP LOCATION

FIGURE R804.3.3.4(5)HIP MEMBER CONNECTION AT WALL CORNER

54M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:30 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 55: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

2009 VIRGINIA RESIDENTIAL CODE 8-55

ROOF-CEILING CONSTRUCTION

NO. 8 SCREWS AT 24 IN. O.C.TOP AND BOTTOM (TYP.)

HEADER JOISTC-SHAPE INSIDE A TRACK

4 NO. 8 SCREWS THROUGH EACH LEGOF CLIP ANGLE (ONE SIDE OFCONNECTION) MINIMUM LENGTH EQUALS

JOIST WEB DEPTH MINUS / IN.1

2

JOIST/RAFTER

TRIMMER JOISTC-SHAPE INSIDEA TRACK (TYP.)

MINIMUM 2 IN. × 2 IN. CLIP ANGLEWITH 4 NO. 8 SCREWSTHROUGH EACH LEG, BOTHSIDES OF CONNECTION

For SI: 1 inch = 25.4 mm.

FIGURE R804.3.6(2)HEADER TO TRIMMER CONNECTION

TABLE R804.3.8(1)REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS

GYPSUM BOARD SHEATHED, CEILING HEIGHT = 8 FT a, b, c, d, e, f

Exposure B

BASIC WIND SPEED (mph)

85 100 110 — —

Exposure C — 85 — 100 110

Roof pitch Building endwall width (feet) Minimum diaphragm length (feet)

3:12to

6:12

24 - 28 14 20 22 28 32

28 - 32 16 22 28 32 38

32 - 36 20 26 32 38 44

36 - 40 22 30 36 44 50

6:12to

9:12

24 - 28 16 22 26 32 36

28 - 32 20 26 32 38 44

32 - 36 22 32 38 44 52

36 - 40 26 36 44 52 60

9:12to

12:12

24 - 28 18 26 30 36 42

28 - 32 22 30 36 42 50

32 - 36 26 36 42 50 60

36 - 40 30 42 50 60 70

For SI: 1 inch = 25.4 mm, 1 pound per square foot = 0.0479kPa, 1 mile per hour = 0.447 m/s, 1 foot = 304.8 mm, 1 mil = 0.0254 mm.a. Ceiling diaphragm is composed of 1/2 inch gypsum board (min. thickness) secured with screws spaced at 6 inches o.c. at panel edges and 12 inches o.c. in field. Use

No. 8 screws (min.) when framing members have a designation thickness of 54 mils or less and No. 10 screws (min.) when framing members have a designationthickness greater than 54 mils.

b. Maximum aspect ratio (length/width) of diaphragms is 2:1.c. Building width is in the direction of horizontal framing members supported by the wall studs.d. Required diaphragm lengths are to be provided at each end of the structure.e. Multiplying required diaphragm lengths by 0.35 is permitted if all panel edges are blocked.f. Multiplying required diaphragm lengths by 0.9 is permitted if all panel edges are secured with screws spaced at 4 inches o.c.

55M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:32 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 56: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-56 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

CEILING JOISTS

FLAT STUD OR TRACKBLOCKING AT 48 IN. O.C.AT FIRST TWO JOISTSPACES

3-NO. 8 SCREWS ATEACH STUD

STUD BLOCKINGAT CEILINGELEVATION

GABLE ENDWALL STUDS

NO. 8 SCREWS AT6 INCHES O.C. TOFLAT BLOCKING

WOOD STRUCTURALPANEL OR GYPSUMBOARD DIAPHRAGM

For SI: 1 inch = 25.4 mm.

FIGURE R804.3.8(1)CEILING DIAPHRAGM TO GABLE ENDWALL DETAIL

TABLE R804.3.8(2)REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS

GYPSUM BOARD SHEATHEDCEILING HEIGHT = 9 OR 10 FTa, b, c, d, e, f

Exposure B

BASIC WIND SPEED (mph)

85 100 110 — —

Exposure C — 85 — 100 110

Roof pitch Building endwall width (feet) Minimum diaphragm length (feet)

3:12to

6:12

24 - 28 16 22 26 32 38

28 - 32 20 26 32 38 44

32 - 36 22 30 36 44 50

36 - 40 26 36 42 50 58

6:12to

9:12

24 - 28 18 26 30 36 42

28 - 32 22 30 36 42 50

32 - 36 26 36 42 50 58

36 - 40 30 42 48 58 68

9:12to

12:12

24 - 28 20 28 34 40 46

28 - 32 24 34 40 48 56

32 - 36 28 40 48 56 66

36 - 40 34 46 56 66 78

For SI: 1 inch = 25.4 mm, 1 pound per square foot = 0.0479kPa, 1 mph = 0.447 m/s, 1 foot = 304.8 mm, 1 mil = 0.0254 mm.a. Ceiling diaphragm is composed of 1/2 inch gypsum board (min. thickness) secured with screws spaced at 6 inches o.c. at panel edges and 12 inches o.c. in field. Use

No. 8 screws (min.) when framing members have a designation thickness of 54 mils or less and No. 10 screws (min.) when framing members have a designationthickness greater than 54 mils.

b. Maximum aspect ratio (length/width) of diaphragms is 2:1.c. Building width is in the direction of horizontal framing members supported by the wall studs.d. Required diaphragm lengths are to be provided at each end of the structure.e. Required diaphragm lengths are permitted to be multiplied by 0.35 if all panel edges are blocked.f. Required diaphragm lengths are permitted to be multiplied by 0.9 if all panel edges are secured with screws spaced at 4 inches o.c.

56M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:33 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 57: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

2009 VIRGINIA RESIDENTIAL CODE 8-57

ROOF-CEILING CONSTRUCTION

ROOF SHEATHING

ROOF BLOCKING

NO. 8 SCREWS AT 6 IN. O.C.

STRUCTURAL WALL

ROOF RAFTER(OR TRUSS TOP CHORD)

CEILING JOIST(OR TRUSS BOTTOM CHORD)

WOOD STRUCTURAL PANELOR GYPSUM BOARD DIAPHRAGM

350T125-33 TRACK BLOCKING

For SI: 1 inch = 25.4 mm.

FIGURE R804.3.8(2)CEILING DIAPHRAGM TO SIDEWALL DETAIL

TABLE R804.3.8(3)REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS

WOOD STRUCTURAL PANEL SHEATHEDCEILING HEIGHT = 8, 9 OR 10 FTa, b, c, d

Exposure B

BASIC WIND SPEED (mph)

85 100 110 — —

Exposure C — 85 — 100 110

Roof pitch Building endwall width (feet) Minimum diaphragm length (feet)

3:12to

6:12

24 - 28 10 10 10 10 10

28 - 32 12 12 12 12 12

32 - 36 12 12 12 12 12

36 - 40 14 14 14 14 14

6:12to

9:12

24 - 28 10 10 10 10 10

28 - 32 12 12 12 12 12

32 - 36 12 12 12 12 12

36 - 40 14 14 14 14 14

9:12to

12:12

24 - 28 10 10 10 10 10

28 - 32 12 12 12 12 12

32 - 36 12 12 12 12 12

36 - 40 14 14 14 14 14

For SI: 1 inch = 25.4 mm, 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s, 1 foot = 304.8 mm, 1 mil = 0.0254 mm.a. Ceiling diaphragm is composed of 3/8 inch wood structural panel sheathing (min. thickness) secured with screws spaced at 6 inches o.c. at panel edges and in field.

Use No. 8 screws (min.) when framing members have a designation thickness of 54 mils or less and No. 10 screws (min.) when framing members have a designa-tion thickness greater than 54 mils.

b. Maximum aspect ratio (length/width) of diaphragms is 3:1.c. Building width is in the direction of horizontal framing members supported by the wall studs.d. Required diaphragm lengths are to be provided at each end of the structure.

57M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:34 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 58: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

SECTION R805CEILING FINISHES

R805.1 Ceiling installation. Ceilings shall be installed inaccordance with the requirements for interior wall finishes asprovided in Section R702.

SECTION R806ROOF VENTILATION

R806.1 Ventilation required. Enclosed attics and enclosed raf-ter spaces formed where ceilings are applied directly to theunderside of roof rafters shall have cross ventilation for eachseparate space by ventilating openings protected against theentrance of rain or snow. Ventilation openings shall have a leastdimension of 1/16 inch (1.6 mm) minimum and 1/4 inch (6.4 mm)maximum. Ventilation openings having a least dimension largerthan 1/4 inch (6.4 mm) shall be provided with corrosion-resistantwire cloth screening, hardware cloth, or similar material withopenings having a least dimension of 1/16 inch (1.6 mm) mini-

mum and 1/4 inch (6.4 mm) maximum. Openings in roof framingmembers shall conform to the requirements of Section R802.7.

R806.2 Minimum area. The total net free ventilating areashall not be less than 1/150 of the area of the space ventilatedexcept that reduction of the total area to 1/300 is permitted pro-vided that at least 50 percent and not more than 80 percent ofthe required ventilating area is provided by ventilators locatedin the upper portion of the space to be ventilated at least 3 feet(914 mm) above the eave or cornice vents with the balance ofthe required ventilation provided by eave or cornice vents. Asan alternative, the net free cross-ventilation area may bereduced to 1/300 when a Class I or II vapor retarder is installed onthe warm-in-winter side of the ceiling.

R806.3 Vent and insulation clearance. Where eave or cornicevents are installed, insulation shall not block the free flow ofair. A minimum of a 1-inch (25 mm) space shall be providedbetween the insulation and the roof sheathing and at the loca-tion of the vent.

8-58 2009 VIRGINIA RESIDENTIAL CODE

ROOF-CEILING CONSTRUCTION

1 / IN. × 33 MIL CONT.

STRAP LAP 12 IN. WITH4-NO. 5 SCREWS WHERESPLICE REQUIRED

1

2

SCREW THROUGH ROOFSHEATHING TO STRAPNO. 8 AT 6 IN. O.C.

SHADED AREA INDICATESBLOCKING BREAK SHAPEAT 12 FT O.C.

SCREWS THROUGH STRAPTO BLKG AND BLKG TO TOPOF WALL TRACK FLANGENO. 8 AT 6 IN. O.C.

2 IN.

43 MILBLKG LENGTHREQUIRED TOLAP WALL TRACKFLANGE A MIN.

1 / IN.1

4

ROOFSLOPE

TOPTRACK

NOTE: BLKG SHALLBE PERMITTED TOBE ATTACHED TOOUTSIDE FACE OFSHEATHING OR PREFERABLYDIRECTLY TO TRACKFLANGE PRIOR TO SHEATHINGPLACEMENT AS SHOWN

For SI: 1 mil = 0.0254 mm, 1 inch = 25.4 mm.

FIGURE R804.3.8(3)ROOF BLOCKING DETAIL

58M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:35 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 59: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

R806.4 Unvented attic assemblies. Unvented attic assemblies(spaces between the ceiling joists of the top story and the roofrafters) shall be permitted if all the following conditions are met:

1. The unvented attic space is completely contained withinthe building thermal envelope.

2. No interior vapor retarders are installed on the ceilingside (attic floor) of the unvented attic assembly.

3. Where wood shingles or shakes are used, a minimum 1/4 inch(6 mm) vented air space separates the shingles or shakes andthe roofing underlayment above the structural sheathing.

4. In climate zones 5, 6, 7 and 8, any air-impermeable insu-lation shall be a vapor retarder, or shall have a vaporretarder coating or covering in direct contact with theunderside of the insulation.

5. Either Items 5.1, 5.2 or 5.3 shall be met, depending on theair permeability of the insulation directly under the struc-tural roof sheathing.

5.1. Air-impermeable insulation only. Insulationshall be applied in direct contact with the under-side of the structural roof sheathing.

5.2. Air-permeable insulation only. In addition to theair-permeable installed directly below the struc-tural sheathing, rigid board or sheet insulationshall be installed directly above the structuralroof sheathing as specified in Table R806.4 forcondensation control.

5.3. Air-impermeable and air-permeable insulation.The air-impermeable insulation shall be appliedin direct contact with the underside of the struc-tural roof sheathing as specified in Table R806.4for condensation control. The air-permeableinsulation shall be installed directly under theair-impermeable insulation.

SECTION R807ATTIC ACCESS

R807.1 Attic access. Buildings with combustible ceiling orroof construction shall have an attic access opening to atticareas that exceed 30 square feet (2.8 m2) and have a verticalheight of 30 inches (762 mm) or greater. The vertical heightshall be measured from the top of the ceiling framing membersto the underside of the roof framing members.

The rough-framed opening shall not be less than 22 inchesby 30 inches (559 mm by 762 mm) and shall be located in ahallway or other readily accessible location. When located in awall, the opening shall be a minimum of 22 inches wide by 30inches high. When the access is located in a ceiling, minimumunobstructed headroom in the attic space shall be 30 inches(762 mm) at some point above the access measured verticallyfrom the bottom of ceiling framing members. See SectionM1305.1.3 for access requirements where mechanical equip-ment is located in attics.

2009 VIRGINIA RESIDENTIAL CODE 8-59

ROOF-CEILING CONSTRUCTION

TABLE R806.4INSULATION FOR CONDENSATION CONTROL

CLIMATE ZONEMINIMUM RIGID BOARD ON AIR-IMPERMEABLE

INSULATION R-VALUEa

2B and 3B tile roof only 0 (none required)

1, 2A, 2B, 3A, 3B, 3C R-5

4C R-10

4A, 4B R-15

5 R-20

6 R-25

7 R-30

8 R-35

a. Contributes to but does not supersede Chapter 11 energy requirements.

59M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:35 AM

Color profile: Generic CMYK printer profileComposite Default screen

Page 60: CHAPTER 8 ROOF-CEILING CONSTRUCTION - ecodes.bizecodes.biz/ecodes_support/free_resources/Virginia2009/09Residential... · CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL

8-60 2009 VIRGINIA RESIDENTIAL CODE

60M:\data\CODES\STATE CODES\Virginia\2009\Residential\Final VP\08_Va_Res_2009.vpTuesday, March 01, 2011 11:51:35 AM

Color profile: Generic CMYK printer profileComposite Default screen