CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path Switched Ring” and “UPSR” may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as “Path Protected Mesh Network” and “PPMN,” refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration. The Cisco ONS 15454 integrates Ethernet into a SONET platform through the use of Ethernet cards. This chapter describes the E-Series, G-Series, ML-Series, and CE-Series Ethernet cards. For installation and card turn-up procedures, refer to the Cisco ONS 15454 Procedure Guide. For ML-Series configuration information, refer to the Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration Guide. Chapter topics include: 5.1 Ethernet Card Overview, page 5-2 5.2 E100T-12 Card, page 5-4 5.3 E100T-G Card, page 5-6 5.4 E1000-2 Card, page 5-9 5.5 E1000-2-G Card, page 5-11 5.6 G1K-4 Card, page 5-14 5.7 ML100T-12 Card, page 5-16 5.8 ML100X-8 Card, page 5-18 5.9 ML1000-2 Card, page 5-20 5.10 ML-MR-10 Card, page 5-22 5.11 CE-100T-8 Card, page 5-25 5.12 CE-1000-4 Card, page 5-27 5.13 CE-MR-10 Card, page 5-30 5.14 Ethernet Card GBICs and SFPs, page 5-34

Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

  • Upload
    others

  • View
    12

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Cisco ONS 178-19870-01

C H A P T E R 5

Ethernet Cards

Note The terms “Unidirectional Path Switched Ring” and “UPSR” may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as “Path Protected Mesh Network” and “PPMN,” refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration.

The Cisco ONS 15454 integrates Ethernet into a SONET platform through the use of Ethernet cards. This chapter describes the E-Series, G-Series, ML-Series, and CE-Series Ethernet cards. For installation and card turn-up procedures, refer to the Cisco ONS 15454 Procedure Guide. For ML-Series configuration information, refer to the Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration Guide.

Chapter topics include:

• 5.1 Ethernet Card Overview, page 5-2

• 5.2 E100T-12 Card, page 5-4

• 5.3 E100T-G Card, page 5-6

• 5.4 E1000-2 Card, page 5-9

• 5.5 E1000-2-G Card, page 5-11

• 5.6 G1K-4 Card, page 5-14

• 5.7 ML100T-12 Card, page 5-16

• 5.8 ML100X-8 Card, page 5-18

• 5.9 ML1000-2 Card, page 5-20

• 5.10 ML-MR-10 Card, page 5-22

• 5.11 CE-100T-8 Card, page 5-25

• 5.12 CE-1000-4 Card, page 5-27

• 5.13 CE-MR-10 Card, page 5-30

• 5.14 Ethernet Card GBICs and SFPs, page 5-34

5-15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

Page 2: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards 5.1 Ethernet Card Overview

5.1 Ethernet Card OverviewThe card overview section summarizes the Ethernet card functions and provides the software compatibility for each card.

Note Each card is marked with a symbol that corresponds to a slot (or slots) on the ONS 15454 shelf assembly. The cards are then installed into slots displaying the same symbols. Refer to the Cisco ONS 15454 Procedure Guide for a list of slots and symbols.

5.1.1 Ethernet CardsTable 5-1 lists the Cisco ONS 15454 Ethernet cards.

Table 5-1 Ethernet Cards for the ONS 15454

Card Port Description For Additional Information...

E100T-12 The E100T-12 card provides 12 switched, autosensing, 10/100BaseT Ethernet ports and is compatible with the XCVT card.

See the “5.2 E100T-12 Card” section on page 5-4.

E100T-G The E100T-G card provides 12 switched, autosensing, 10/100BaseT Ethernet ports and is compatible with the XC10G and XC-VXC-10G cards.

See the “5.3 E100T-G Card” section on page 5-6.

E1000-2 The E1000-2 card provides two IEEE-compliant, 1000-Mbps ports. Gigabit Interface Converters (GBICs) are separate.

See the “5.4 E1000-2 Card” section on page 5-9.

E1000-2-G The E1000-2-G card provides two IEEE-compliant, 1000-Mbps ports. GBICs are separate. The E1000-2-G card is compatible with the XC10G and XC-VXC-10G cards.

See the “5.5 E1000-2-G Card” section on page 5-11.

G1K-4 The G1K-4 card provides four IEEE-compliant, 1000-Mbps ports. GBICs are separate. The G1K-4 card can operate with XCVT, XC10G and XC-VXC-10G cross-connect cards.

See the “5.6 G1K-4 Card” section on page 5-14.

M100T-12 The ML100T-12 card provides 12 switched, autosensing, 10/100Base-T Ethernet ports.

See the “5.7 ML100T-12 Card” section on page 5-16.

M100X-8 The ML100X-8 card provides eight switched, 100BaseFX Ethernet ports.

See the “5.8 ML100X-8 Card” section on page 5-18.

M1000-2 The ML1000-2 card provides two IEEE-compliant, 1000-Mbps ports. Small Form-factor Pluggable (SFP) connectors are separate.

See the “5.9 ML1000-2 Card” section on page 5-20.

ML-MR-10 The ML-MR-10 card is a ten-port multilayer Ethernet card. The Ethernet ports support speeds of 10 Mbps, 100 Mbps, or 1000 Mbps through pluggable SFPs.

See the “5.10 ML-MR-10 Card” section on page 5-22.

5-2Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 3: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

5-378-19870-01

Chapter 5 Ethernet Cards5.1.2 Card Com

patibility

the individual card reference

Table 5-1 Ethernet Cards for the ONS 15454 (continued)

R9.2 R9.2.1

Yes Yes

Yes Yes

Yes Yes

Yes Yes

— —

Yes Yes

Cisco ON

S 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

5.1.2 Card CompatibilityTable 5-2 lists the CTC software compatibility for each Ethernet card.

Note “Yes” indicates that this card is fully or partially supported by the indicated software release. Refer tosection for more information about software limitations for this card.

CE-100T-8 The CE-100T-8 card provides eight IEEE-compliant, 10/100-Mbps ports. The CE-100T-8 can operate with the XC10G, XC-VXC-10G, or XCVT cross-connect cards.

See the “5.11 CE-100T-8 Card” section on page 5-25.

CE-MR-10 The CE-MR-10 card is a ten-port Ethernet card. The Ethernet ports support speeds of 10 Mbps, 100 Mbps, or 1000 Mbps through pluggable SFPs.

See the “5.13 CE-MR-10 Card” section on page 5-30.

CE-1000-4 The CE-1000-4 card provides four IEEE-compliant, 1000-Mbps ports. The CE-1000-4 card can operate with the XC10G, XC-VXC-10G, or XCVT cross-connect cards.

See the “5.12 CE-1000-4 Card” section on page 5-27.

CE-MR-10 The CE-MR-10 card provides ten IEEE-compliant, 10/100/1000-Mbps ports. The CE-MR-10 card can operate with the XC10G, XC-VXC-10G, or XCVT cross-connect cards.

See the “5.13 CE-MR-10 Card” section on page 5-30.

Card Port Description For Additional Information...

Table 5-2 Ethernet Card Software Compatibility

EthernetCards

R3.0.1 R3.1 R3.2 R3.3 R3.4 R4.0 R4.1

R4.5 R4.6

R4.7 R5.0 R6.0 R7.0 R7.2 R8.0 R8.5 R9.0 R9.1

E100T-12 Yes Yes Yes Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes Yes Yes

E1000-2 Yes Yes Yes Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes Yes Yes

E100T-G Yes Yes Yes Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes Yes Yes

E1000-2-G Yes Yes Yes Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes Yes Yes

G1000-4 — — Yes Yes Yes Yes Yes — Yes — Yes Yes Yes Yes — — — —

G1K-4 — — Yes Yes Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes Yes Yes

Page 4: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

5-4

Chapter 5 Ethernet Cards5.2 E100T-12 Card

.

h card provides 12 switched, attached device (autosense) and r full duplex and determine 5-1 shows the faceplate and a

es Yes Yes

es Yes Yes

es Yes Yes

es Yes Yes

es Yes Yes

es Yes Yes

es Yes Yes

Table 5-2 Ethernet Card Software Compatibility (continued)

Ethernet 9.1 R9.2 R9.2.1

Cisco ON

S 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

5.2 E100T-12 Card

Note For hardware specifications, see the “A.7.1 E100T-12 Card Specifications” section on page A-49

The ONS 15454 uses E100T-12 cards for Ethernet (10 Mbps) and Fast Ethernet (100 Mbps). EacIEEE 802.3-compliant, 10/100BaseT Ethernet ports that can independently detect the speed of anautomatically connect at the appropriate speed. The ports autoconfigure to operate at either half owhether to enable or disable flow control. You can also configure Ethernet ports manually. Figureblock diagram of the card.

ML100T-12 — — — — — Yes Yes — Yes — Yes Yes Yes Yes Yes Yes Yes Y

ML100X-8 — — — — — — — — — — — Yes Yes Yes Yes Yes Yes Y

ML1000-2 — — — — — Yes Yes — Yes — Yes Yes Yes Yes Yes Yes Yes Y

ML-MR-10 — — — — — — — — — — — — — — — Yes Yes Y

CE-100T-8 — — — — — — — — — — Yes Yes Yes Yes Yes Yes Yes Y

CE-1000-4 — — — — — — — — — — — — Yes Yes Yes Yes Yes Y

CE-MR-10 — — — — — — — — — — — — — — — Yes Yes Y

Cards R3.0.1 R3.1 R3.2 R3.3 R3.4 R4.0 R4.1 R4.5 R4.6 R4.7 R5.0 R6.0 R7.0 R7.2 R8.0 R8.5 R9.0 R

Page 5: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards5.2.1 Slot Compatibility

Figure 5-1 E100T-12 Faceplate and Block Diagram

The E100T-12 Ethernet card provides high-throughput, low-latency packet switching of Ethernet traffic across a SONET network while providing a greater degree of reliability through SONET self-healing protection services. This Ethernet capability enables network operators to provide multiple 10/100-Mbps access drops for high-capacity customer LAN interconnects, Internet traffic, and cable modem traffic aggregation. It enables the efficient transport and co-existence of traditional time-division multiplexing (TDM) traffic with packet-switched data traffic.

Each E100T-12 card supports standards-based, wire-speed, Layer 2 Ethernet switching between its Ethernet interfaces. The IEEE 802.1Q tag logically isolates traffic (typically subscribers). IEEE 802.1Q also supports multiple classes of service.

5.2.1 Slot CompatibilityYou can install the E100T-12 card in Slots 1 to 6 and 12 to 17. Multiple E-Series Ethernet cards installed in an ONS 15454 can act independently or as a single Ethernet switch. You can create logical SONET ports by provisioning synchronous transport signal (STS) channels to the packet switch entity within the ONS 15454. Logical ports can be created with a bandwidth granularity of STS-1. The E100T-12 supports STS-1, STS-3c, STS-6c, and STS-12c circuit sizes.

10/100PHYS

A/D Mux

Flash DRAM CPU

Buffermemory

Controlmemory

EthernetMACs/switch

6136

2

FPGA BTC

Backplane

1

2

3

4

5

6

7

8

9

10

11

12

FAIL

ACT

SF

E100T12

5-5Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 6: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards 5.2.2 E100T-12 Card-Level Indicators

Note When making an STS-12c Ethernet circuit, the E-Series cards must be configured as single-card EtherSwitch.

5.2.2 E100T-12 Card-Level IndicatorsThe E100T-12 card faceplate has two card-level LED indicators, described in Table 5-3.

5.2.3 E100T-12 Port-Level IndicatorsThe E100T-12 card has 12 pairs of LEDs (one pair for each port) to indicate port conditions. Table 5-4 lists the port-level indicators. You can find the status of the E100T-12 card port using the LCD on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot.

5.2.4 Cross-Connect CompatibilityThe E100T-12 card is compatible with the XCVT card. Do not use the E100T-12 card with the XC10G and XC-VXC-10G cards.

5.3 E100T-G Card

Note For hardware specifications, see the “A.7.2 E100T-G Card Specifications” section on page A-49.

Table 5-3 E100T-12 Card-Level Indicators

Card-Level Indicators Description

FAIL LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the E100T-12 card. As part of the boot sequence, the FAIL LED is on until the software deems the card operational.

ACT LED (Green) The green ACT LED provides the operational status of the E100T-12. If the ACT LED is green, it indicates that the E100T-12 card is active and the software is operational.

SF LED Not used.

Table 5-4 E100T-12 Port-Level Indicators

LED State Description

Amber The port is active (transmitting and receiving data).

Solid green The link is established.

Off The connection is inactive, or traffic is unidirectional.

5-6Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 7: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards5.3 E100T-G Card

The ONS 15454 uses E100T-G cards for Ethernet (10 Mbps) and Fast Ethernet (100 Mbps). Each card provides 12 switched, IEEE 802.3-compliant, 10/100BaseT Ethernet ports that can independently detect the speed of an attached device (autosense) and automatically connect at the appropriate speed. The ports autoconfigure to operate at either half or full duplex and determine whether to enable or disable flow control. You can also configure Ethernet ports manually. Figure 5-2 shows the faceplate and a block diagram of the card.

Figure 5-2 E100T-G Faceplate and Block Diagram

The E100T-G Ethernet card provides high-throughput, low-latency packet switching of Ethernet traffic across a SONET network while providing a greater degree of reliability through SONET self-healing protection services. This Ethernet capability enables network operators to provide multiple 10/100 Mbps access drops for high-capacity customer LAN interconnects, Internet traffic, and cable modem traffic aggregation. It enables the efficient transport and co-existence of traditional TDM traffic with packet-switched data traffic.

Each E100T-G card supports standards-based, wire-speed, Layer 2 Ethernet switching between its Ethernet interfaces. The IEEE 802.1Q tag logically isolates traffic (typically subscribers). IEEE 802.1Q also supports multiple classes of service.

Note When making an STS-12c Ethernet circuit, the E-Series cards must be configured as single-card EtherSwitch.

10/100PHYS

A/D Mux

Flash DRAM CPU

Buffermemory

Controlmemory

EthernetMACs/switch

6187

7

FPGA BTC

Backplane

1

2

3

4

5

6

7

8

9

10

11

12

FAIL

ACT

SF

E100T-G

5-7Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 8: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards 5.3.1 Slot Compatibility

5.3.1 Slot CompatibilityYou can install the E100T-G card in Slots 1 to 6 and 12 to 17. Multiple E-Series Ethernet cards installed in an ONS 15454 can act independently or as a single Ethernet switch. You can create logical SONET ports by provisioning a number of STS channels to the packet switch entity within the ONS 15454. Logical ports can be created with a bandwidth granularity of STS-1. The ONS 15454 supports STS-1, STS-3c, STS-6c, or STS-12c circuit sizes.

5.3.2 E100T-G Card-Level IndicatorsThe E100T-G card faceplate has two card-level LED indicators, described in Table 5-5.

5.3.3 E100T-G Port-Level IndicatorsThe E100T-G card has 12 pairs of LEDs (one pair for each port) to indicate port conditions (Table 5-6). You can find the status of the E100T-G card port using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot.

5.3.4 Cross-Connect CompatibilityThe E100T-G card is compatible with the XCVT, XC10G and XC-VXC-10G cards.

Table 5-5 E100T-G Card-Level Indicators

Card-Level Indicators Description

FAIL LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the E100T-G card. As part of the boot sequence, the FAIL LED is turned on until the software deems the card operational.

ACT LED (Green) The green ACT LED provides the operational status of the E100T-G. If the ACT LED is green it indicates that the E100T-G card is active and the software is operational.

SF LED Not used.

Table 5-6 E100T-G Port-Level Indicators

LED State Description

Yellow (Active) Port is active (transmitting or receiving data). By default, indicates the transmitter is active but can be software controlled to indicate link status, duplex status, or receiver active.

Solid Green (Link) Link is established. By default, indicates the link for this port is up, but can be software controlled to indicate duplex status, operating speed, or collision.

5-8Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 9: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards5.4 E1000-2 Card

5.4 E1000-2 Card

Note For hardware specifications, see the “A.7.3 E1000-2 Card Specifications” section on page A-49.

The ONS 15454 uses E1000-2 cards for Gigabit Ethernet (1000 Mbps). The E1000-2 card provides two IEEE-compliant, 1000-Mbps ports for high-capacity customer LAN interconnections. Each port supports full-duplex operation.

The E1000-2 card uses GBIC modular receptacles for the optical interfaces. For details, see the “5.14 Ethernet Card GBICs and SFPs” section on page 5-34.

Figure 5-3 shows the card faceplate and a block diagram of the card.

Figure 5-3 E1000-2 Faceplate and Block Diagram

The E1000-2 Gigabit Ethernet card provides high-throughput, low-latency packet switching of Ethernet traffic across a SONET network while providing a greater degree of reliability through SONET self-healing protection services. This enables network operators to provide multiple 1000-Mbps access drops for high-capacity customer LAN interconnects. It enables efficient transport and co-existence of traditional TDM traffic with packet-switched data traffic.

Gigabit EthernetPHYS

A/D Mux

Flash DRAM CPU

Buffermemory

Controlmemory

EthernetMACs/switch

6136

3FPGA BTC

Backplane

E10002

FAIL

ACT

1

SF

33678 12931

2

RX

TX

RX

TX

ACT/LINK

ACT/LINK

5-9Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 10: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards 5.4.1 Slot Compatibility

Each E1000-2 card supports standards-based, Layer 2 Ethernet switching between its Ethernet interfaces and SONET interfaces on the ONS 15454. The IEEE 802.1Q VLAN tag logically isolates traffic (typically subscribers).

Multiple E-Series Ethernet cards installed in an ONS 15454 can act together as a single switching entity or as independent single switches supporting a variety of SONET port configurations.

You can create logical SONET ports by provisioning STS channels to the packet switch entity within the ONS 15454. Logical ports can be created with a bandwidth granularity of STS-1. The ONS 15454 supports STS-1, STS-3c, STS-6c, or STS-12c circuit sizes.

Note When making an STS-12c circuit, the E-Series cards must be configured as single-card EtherSwitch.

5.4.1 Slot CompatibilityYou can install the E1000-2 card in Slots 1 to 6 and 12 to 17. The E1000-2 is compatible with the XCVT card but not the XC10G or and XC-VXC-10G cards. The E1000-2-G is compatible with the XC10G and XC-VXC-10G.

5.4.2 E1000-2 Card-Level IndicatorsThe E1000-2 card faceplate has two card-level LED indicators, described in Table 5-7.

5.4.3 E1000-2 Port-Level IndicatorsThe E1000-2 card has one bicolor LED per port (Table 5-8). When the LED is solid green, it indicates that carrier is detected, meaning an active network cable is installed. When the LED is off, it indicates that an active network cable is not plugged into the port, or the card is carrying unidirectional traffic. When the LED flashes amber, it does so at a rate proportional to the level of traffic being received and transmitted over the port.

Table 5-7 E1000-2 Card-Level Indicators

Card-Level Indicators Description

FAIL LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the E1000-2 card. As part of the boot sequence, the FAIL LED is turned on until the software deems the card operational.

ACT LED (Green) The green ACT LED provides the operational status of the E1000-2. When the ACT LED is green it indicates that the E1000-2 card is active and the software is operational.

SF LED Not used.

5-10Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 11: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards5.4.4 Cross-Connect Compatibility

5.4.4 Cross-Connect CompatibilityThe E1000-2 is compatible with XCVT cards. The XC10G and XC-VXC-10G cards require the E1000-2-G card.

5.5 E1000-2-G Card

Note For hardware specifications, see the “A.7.4 E1000-2-G Card Specifications” section on page A-50.

The ONS 15454 uses E1000-2-G cards for Gigabit Ethernet (1000 Mbps). The E1000-2-G card provides two IEEE-compliant, 1000-Mbps ports for high-capacity customer LAN interconnections. Each port supports full-duplex operation.

The E1000-2-G card uses GBIC modular receptacles for the optical interfaces. For details, see the “5.14 Ethernet Card GBICs and SFPs” section on page 5-34.

Figure 5-4 shows the card faceplate and a block diagram of the card.

Table 5-8 E1000-2 Port-Level Indicators

LED State Description

Amber The port is active (transmitting and receiving data).

Solid green The link is established.

Off The connection is inactive, or traffic is unidirectional.

5-11Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 12: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards 5.5 E1000-2-G Card

Figure 5-4 E1000-2-G Faceplate and Block Diagram

The E1000-2-G Gigabit Ethernet card provides high-throughput, low-latency packet switching of Ethernet traffic across a SONET network while providing a greater degree of reliability through SONET self-healing protection services. This enables network operators to provide multiple 1000-Mbps access drops for high-capacity customer LAN interconnects. It enables efficient transport and co-existence of traditional TDM traffic with packet-switched data traffic.

Each E1000-2-G card supports standards-based, Layer 2 Ethernet switching between its Ethernet interfaces and SONET interfaces on the ONS 15454. The IEEE 802.1Q VLAN tag logically isolates traffic (typically subscribers).

Multiple E-Series Ethernet cards installed in an ONS 15454 can act together as a single switching entity or as independent single switches supporting a variety of SONET port configurations.

Gigabit EthernetPHYS

A/D Mux

Flash DRAM CPU

Buffermemory

Controlmemory

EthernetMACs/switch

6187

8

FPGA BTC

Backplane

E1000-2-G

FAIL

ACT

1

SF

33678 12931

2

RX

TX

RX

TX

ACT/LINK

ACT/LINK

5-12Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 13: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards5.5.1 E1000-2-G Card-Level Indicators

You can create logical SONET ports by provisioning STS channels to the packet switch entity within the ONS 15454. Logical ports can be created with a bandwidth granularity of STS-1. The ONS 15454 supports STS-1, STS-3c, STS-6c, or STS-12c circuit sizes.

Note When making an STS-12c Ethernet circuit, the E-Series cards must be configured as a single-card EtherSwitch.

5.5.1 E1000-2-G Card-Level IndicatorsThe E1000-2-G card faceplate has two card-level LED indicators, described in Table 5-9.

5.5.2 E1000-2-G Port-Level IndicatorsThe E1000-2-G card has one bicolor LED per port (Table 5-10). When the green LINK LED is on, carrier is detected, meaning an active network cable is installed. When the green LINK LED is off, an active network cable is not plugged into the port, or the card is carrying unidirectional traffic. The amber port ACT LED flashes at a rate proportional to the level of traffic being received and transmitted over the port.

5.5.3 Cross-Connect CompatibilityThe E1000-2-G is compatible with the XCVT, XC10G, and XC-VXC-10G cards. You can install the card in Slots 1 to 6 and 12 to 17.

Table 5-9 E1000-2-G Card-Level Indicators

Card-Level Indicators Description

FAIL LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the E1000-2-G card. As part of the boot sequence, the FAIL LED is turned on until the software deems the card operational.

ACT LED (Green) The green ACT LED provides the operational status of the E1000-2-G. If the ACT LED is green it indicates that the E1000-2-G card is active and the software is operational.

SF LED The SF LED is not used in the current release.

Table 5-10 E1000-2-G Port-Level Indicators

LED State Description

Amber The port is active (transmitting and receiving data).

Solid green The link is established.

Off The connection is inactive, or traffic is unidirectional.

5-13Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 14: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards 5.6 G1K-4 Card

5.6 G1K-4 Card

Note For hardware specifications, see the “A.7.8 G1K-4 Card Specifications” section on page A-51.

The G1K-4 card is the functional equivalent of the earlier G1000-4 card and provides four ports of IEEE-compliant, 1000-Mbps interfaces. Each interface supports full-duplex operation for a maximum bandwidth of 1 Gbps or 2 Gbps bidirectional per port, and 2.5 Gbps or 5 Gbps bidirectional per card. Each port autonegotiates for full duplex and IEEE 802.3x flow control. The G1K-4 card uses GBIC modular receptacles for the optical interfaces. For details, see the “5.14 Ethernet Card GBICs and SFPs” section on page 5-34.

Figure 5-5 shows the card faceplate and the block diagram of the card.

Figure 5-5 G1K-4 Faceplate and Block Diagram

The G1K-4 Gigabit Ethernet card provides high-throughput, low-latency transport of Ethernet encapsulated traffic (IP and other Layer 2 or Layer 3 protocols) across a SONET network while providing a greater degree of reliability through SONET self-healing protection services. Carrier-class Ethernet transport is achieved by hitless (< 50 ms) performance in the event of any failures or protection

Flash DRAM CPU

8364

9

Backplane

GBICs

DecodePLD

Trans-ceivers

EthernetMACs/switch

Mux/DemuxFPGA

Inter-face

FPGABTCPOS

function

Buffermemory

Protect/MainRx/TxBPIAs

Power Clockgeneration

To FPGA, BTC, MACs

FAIL

ACT

G1K

RX

1

TX

RX

2

TX

RX

3

TX

RX

4

TX

ACT/LINK

ACT/LINK

ACT/LINK

ACT/LINK

5-14Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 15: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards5.6.1 STS-24c Restriction

switches (such as 1+1 APS, path protection, BLSR, or optical equipment protection) and by full provisioning and manageability, as in SONET service. Full provisioning support is possible through CTC or CTM. Each G1K-4 card performs independently of the other cards in the same shelf.

5.6.1 STS-24c RestrictionDue to hardware constraints, the card imposes an additional restriction on the combinations of circuits that can be dropped onto a G-Series card. These restrictions are transparently enforced by the ONS 15454, and you do not need to keep track of restricted circuit combinations.

When a single STS-24c terminates on a card, the remaining circuits on that card can be another single STS-24c or any combination of circuits of STS-12c size or less that add up to no more than 12 STSs (that is a total of 36 STSs on the card).

If STS-24c circuits are not being dropped on the card, the full 48 STSs bandwidth can be used with no restrictions (for example, using either a single STS-48c or 4 STS-12c circuits).

Note The STS-24c restriction only applies when a single STS-24c circuit is dropped; therefore, you can easily minimize the impact of this restriction. Group the STS-24c circuits together on a card separate from circuits of other sizes. The grouped circuits can be dropped on other G-Series cards on the ONS 15454.

5.6.2 G1K-4 CompatibilityThe G1K-4 card operates with the XCVT, XC10G or XC-VXC-10G cards. With the XC10G or XC-VXC-10G cards, you can install the G1K-4 card in Slots 1 to 6 and 12 to 17, for a total shelf capacity of 48 Gigabit Ethernet ports. (The practical limit is 40 ports because at least two slots are typically populated by optical cards such as OC-192). When used with the XCVT cards, the G1K-4 is limited to Slots 5, 6, 12, and 13.

5.6.3 G1K-4 Card-Level IndicatorsThe G1K-4 card faceplate has two card-level LED indicators, described in Table 5-11.

Table 5-11 G1K-4 Card-Level Indicators

Card-Level LEDs Description

FAIL LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the G1K-4 card. As part of the boot sequence, the FAIL LED is turned on, and it goes off when the software is deemed operational.

The red FAIL LED blinks when the card is loading software.

ACT LED (Green) The green ACT LED provides the operational status of the G1K-4. If the ACT LED is green, it indicates that the G1K-4 card is active and the software is operational.

5-15Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 16: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards 5.6.4 G1K-4 Port-Level Indicators

5.6.4 G1K-4 Port-Level IndicatorsThe G1K-4 card has four bicolor LEDs (one LED per port). Table 5-12 describes the status that each color represents.

5.7 ML100T-12 Card

Note For hardware specifications, see the “A.7.9 ML100T-12 Card Specifications” section on page A-52.

The ML100T-12 card provides 12 ports of IEEE 802.3-compliant, 10/100 interfaces. Each interface supports full-duplex operation for a maximum bandwidth of 200 Mbps per port and 2.488 Gbps per card. Each port independently detects the speed of an attached device (autosenses) and automatically connects at the appropriate speed. The ports autoconfigure to operate at either half or full duplex and can determine whether to enable or disable flow control. For ML-Series configuration information, see the Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration Guide.

Figure 5-6 shows the card faceplate and block diagram.

Caution Shielded twisted-pair cabling should be used for inter-building applications.

Table 5-12 G1K-4 Port-Level Indicators

Port-Level LED Status Description

Off No link exists to the Ethernet port.

Steady amber A link exists to the Ethernet port, but traffic flow is inhibited. For example, a lack of circuit setup, an error on the line, or a nonenabled port might inhibit traffic flow.

Solid green A link exists to the Ethernet port, but no traffic is carried on the port.

Flashing green A link exists to the Ethernet port, and traffic is carried on the port. The LED flash rate reflects the traffic rate for the port.

5-16Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 17: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards5.7.1 ML100T-12 Card-Level Indicators

Figure 5-6 ML100T-12 Faceplate and Block Diagram

The card features two virtual packet over SONET (POS) ports with a maximum combined bandwidth of STS-48. The ports function in a manner similar to OC-N card ports, and each port carries an STS circuit with a size of STS-1, STS-3c, STS-6c, STS-9c, STS-12c, or STS-24c. To configure an ML-Series card SONET STS circuit, refer to the “Create Circuits and VT Tunnels” chapter of the Cisco ONS 15454 Procedure Guide.

The ML-Series POS ports supports virtual concatenation (VCAT) of SONET circuits and a software link capacity adjustment scheme (SW-LCAS). The ML-Series card supports a maximum of two VCAT groups with each group corresponding to one of the POS ports. Each VCAT group must be provisioned with two circuit members. An ML-Series card supports STS-1c-2v, STS-3c-2v and STS-12c-2v. To configure an ML-Series card SONET VCAT circuit, refer to the “Create Circuits and VT Tunnels” chapter of the Cisco ONS 15454 Procedure Guide.

5.7.1 ML100T-12 Card-Level IndicatorsThe ML00T-12 card supports two card-level LED indicators. The card-level indicators are described in Table 5-13.

1

2

3

4

5

6

7

8

9

10

11

ACT

FAIL

ML100T12

1346

21

0

DOSFPGA BTC192

port1

4xMag.

12 xRJ45

OctalPHY

port0

SMII RGGI

OctalPHY

4xMag.

4xMag.

46

portA

portB

port3

port2

port0

port1

ch0-1 ch4-5

6

RGGI

SCL

Backplane

BPIAMainRx

BPIAProtect

Rx

BPIAMainTx

BPIAProtect

Tx

ProcessorDaughter Card

128MB SDRAM16MB FLASH8KB NVRAM

PacketBuffer6MB

PacketBuffer6MB

PacketBuffer4MB

4

2

2

4

4

2

2

Control Mem2MB

Control Mem2MB

Result Mem2MB

5-17Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 18: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards 5.7.2 ML100T-12 Port-Level Indicators

5.7.2 ML100T-12 Port-Level IndicatorsThe ML100T-12 card provides a pair of LEDs for each Fast Ethernet port: an amber LED for activity (ACT) and a green LED for LINK. The port-level indicators are described in Table 5-14.

5.7.3 Cross-Connect and Slot CompatibilityThe ML100T-12 card works in Slots 1 to 6 or 12 to 17 with the XC10G or XC-VXC-10G card. It works only in Slots 5, 6, 12, or 13 with the XCVT card.

5.8 ML100X-8 Card

Note For hardware specifications, see the “A.7.11 ML100X-8 Card Specifications” section on page A-53.

The ML100X-8 card provides eight ports with 100BaseFX interfaces. The FX interfaces support one of two connectors, an LX SFP or an FX SFP. The LX SFP is a 100 Mbps 802.3-compliant SFP that operates over a pair of single-mode optical fibers and includes LC connectors. The FX SFP is a 100 Mbps 802.3- compliant SFP that operates over a pair of multimode optical fibers and includes LC connectors. For more information on SFPs, see the “5.14 Ethernet Card GBICs and SFPs” section on page 5-34.

Each interface supports full-duplex operation for autonegotiation and a maximum bandwidth of 200 Mbps per port and 2.488 Gbps per card. For ML-Series configuration information, see the Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration Guide.

Table 5-13 ML100T-12 Card-Level Indicators

Card-Level LEDs Description

FAIL LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the ML100T-12 card. As part of the boot sequence, the FAIL LED is turned on until the software deems the card operational.

ACT LED (Green) The green ACT LED provides the operational status of the ML100T-12. If the ACT LED is green, it indicates that the ML100T-12 card is active and the software is operational.

Table 5-14 ML100T-12 Port-Level Indicators

Port-Level Indicators Description

ACT LED (Amber) A steady amber LED indicates a link is detected, but there is an issue inhibiting traffic. A blinking amber LED means traffic is flowing.

LINK LED (Green) A steady green LED indicates that a link is detected, but there is no traffic. A blinking green LED flashes at a rate proportional to the level of traffic being received and transmitted over the port.

Both ACT and LINK LED Unlit green and amber LEDs indicate no traffic.

5-18Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 19: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards5.8 ML100X-8 Card

Figure 5-7 shows the card faceplate and block diagram.

Figure 5-7 ML100X-8 Faceplate and Block Diagram

The card features two virtual packet over SONET (POS) ports with a maximum combined bandwidth of STS-48. The ports function in a manner similar to OC-N card ports, and each port carries an STS circuit with a size of STS-1, STS-3c, STS-6c, STS-9c, STS-12c, or STS-24c. To configure an ML-Series card SONET STS circuit, refer to the “Create Circuits and VT Tunnels” chapter of the Cisco ONS 15454 Procedure Guide.

The ML-Series POS ports supports virtual concatenation (VCAT) of SONET circuits and a software link capacity adjustment scheme (SW-LCAS). The ML-Series cards support a maximum of two VCAT groups with each group corresponding to one of the POS ports. Each VCAT group must be provisioned with two circuit members. An ML-Series card supports STS-1c-2v, STS-3c-2v and STS-12c-2v. To configure an ML-Series-card SONET VCAT circuit, refer to the “Create Circuits and VT Tunnels” chapter of the Cisco ONS 15454 Procedure Guide.

1317

86

ML 100X-8

FAIL

ACT

Tx0Rx

Tx1Rx

Tx2Rx

Tx3Rx

Tx4Rx

Tx5Rx

Tx6Rx

Tx7Rx

PHY

SFP

SFP

SFP

SFP

SFP

SFP

SFP

SFP

NetworkProcessor

Unit

TCAM

SONETFramer

PacketMemory

Backplane

5-19Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 20: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards 5.8.1 ML100X-8 Card-Level Indicators

5.8.1 ML100X-8 Card-Level IndicatorsThe ML100X-8 card supports two card-level LED indicators. Table 5-15 describes the card-level indicators.

5.8.2 ML100X-8 Port-Level IndicatorsThe ML100X-8 card provides a pair of LEDs for each Fast Ethernet port: an amber LED for activity (ACT) and a green LED for LINK. Table 5-16 describes the port-level indicators.

5.8.3 Cross-Connect and Slot CompatibilityThe ML100X-8 card operates in Slots 1 to 6 or 12 to 17 with the XC10G or XC-VXC-10G cards. It operates only in Slots 5, 6, 12, or 13 with the XCVT card.

5.9 ML1000-2 Card

Note For hardware specifications, see the “A.7.10 ML1000-2 Card Specifications” section on page A-52.

The ML1000-2 card provides two ports of IEEE-compliant, 1000-Mbps interfaces. Each interface supports full-duplex operation for a maximum bandwidth of 2 Gbps per port and 4 Gbps per card. Each port autoconfigures for full duplex and IEEE 802.3x flow control.

Table 5-15 ML100X-8 Card-Level Indicators

Card-Level LEDs Description

FAIL LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the ML100-FX card. As part of the boot sequence, the FAIL LED is turned on until the software deems the card operational.

ACT LED (Green) The green ACT LED provides the operational status of the ML100-FX. If the ACT LED is green, it indicates that the ML100-FX card is active and the software is operational.

Table 5-16 ML100X-8 Port-Level Indicators

Port-Level Indicators Description

ACT LED (Amber) A steady amber LED indicates a link is detected, but there is an issue inhibiting traffic. A blinking amber LED means traffic is flowing.

LINK LED (Green) A steady green LED indicates that a link is detected, but there is no traffic. A blinking green LED flashes at a rate proportional to the level of traffic being received and transmitted over the port.

Both ACT and LINK LED Unlit green and amber LEDs indicate no traffic.

5-20Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 21: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards5.9 ML1000-2 Card

SFP modules are offered as separate orderable products for maximum customer flexibility. For details, see the “5.14 Ethernet Card GBICs and SFPs” section on page 5-34.

Figure 5-8 shows the ML1000-2 card faceplate and block diagram.

Figure 5-8 ML1000-2 Faceplate and Block Diagram

The card features two virtual packet over SONET (POS) ports with a maximum combined bandwidth of STS-48. The ports function in a manner similar to OC-N card ports, and each port carries an STS circuit with a size of STS-1, STS-3c, STS-6c, STS-9c, STS-12c, or STS-24c. To configure an ML-Series card SONET STS circuit, refer to the “Create Circuits and VT Tunnels” chapter of the Cisco ONS 15454 Procedure Guide.

The ML-Series POS ports supports VCAT of SONET circuits and a software link capacity adjustment scheme (SW-LCAS). The ML-Series card supports a maximum of two VCAT groups with each group corresponding to one of the POS ports. Each VCAT group must be provisioned with two circuit members. An ML-Series card supports STS-1c-2v, STS-3c-2v and STS-12c-2v. To configure an ML-Series card SONET VCAT circuit, refer to the “Create Circuits and VT Tunnels” chapter of the Cisco ONS 15454 Procedure Guide.

1346

22

BTC192

Backplane

BPIAMainRx

BPIAProtect

Rx

BPIAMainTx

BPIAProtect

Tx

ProcessorDaughter Card

(FLASHs,SDRAMs)

PacketBuffer

512Kx96

PacketBuffer

512Kx96

SSRAM2x512Kx36

ch0-1 ch4-5Control Mem512Kx32

Control Mem512Kx32

Result Mem512Kx32

DOSFPGA

port2

port3

GMII

RGGI

RGGI

RGGI

RGGI

portA

portB

port3

port2

port0

port1

Serdes

Serdes

SFPGBIC

Module

SFPGBIC

Module

MAC 1 MAC 2

port0

port1

GMII

Panel Port 0

Panel Port 1

FAIL

ACT

TX1

RX

TX0

RX

LINK

ACT

LINK

ACT

CONSOLE

5-21Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 22: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards 5.9.1 ML1000-2 Card-Level Indicators

5.9.1 ML1000-2 Card-Level IndicatorsThe ML1000-2 card faceplate has two card-level LED indicators, described in Table 5-17.

5.9.2 ML1000-2 Port-Level IndicatorsThe ML1000-2 card has three LEDs for each of the two Gigabit Ethernet ports, described in Table 5-18.

5.9.3 Cross-Connect and Slot CompatibilityThe ML1000-2 card is compatible in Slots 1 to 6 or 12 to 17 with the XC10G or XC-VXC-10G card. It is only compatible in Slots 5, 6, 12, or 13 with the XCVT card.

5.10 ML-MR-10 Card

Note For hardware specifications, see the “A.7.12 ML-MR-10 Card Specifications” section on page A-53.

The ML-MR-10 card is a ten-port multilayer Ethernet card. The Ethernet ports support speeds of 10 Mbps, 100 Mbps, or 1000 Mbps through pluggable SFPs. SFP modules are offered as separate orderable products for flexibility. For details, see the “5.14 Ethernet Card GBICs and SFPs” section on page 5-34.

Table 5-17 ML1000-2 Card-Level Indicators

Card-Level LEDs Description

SF LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the ML1000-2 card. As part of the boot sequence, the FAIL LED is turned on until the software deems the card operational.

ACT LED (Green) The green ACT LED provides the operational status of the ML1000-2. When the ACT LED is green, it indicates that the ML1000-2 card is active and the software is operational.

Table 5-18 ML1000-2 Port-Level Indicators

Port-Level Indicators Description

ACT LED (Amber) A steady amber LED indicates a link is detected, but there is an issue inhibiting traffic. A blinking amber LED means traffic flowing.

LINK LED (Green) A steady green LED indicates that a link is detected, but there is no traffic. A blinking green LED flashes at a rate proportional to the level of traffic being received and transmitted over the port.

Both ACT and LINK LED Unlit green and amber LEDs indicate no traffic.

5-22Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 23: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards5.10 ML-MR-10 Card

The ML-MR-10 card has two RPR ports, which function in a manner similar to OC-N card ports. Each Ethernet port carries an STS circuit with a size of STS-12c, STS-24c, STS-48c, or STS-96c. The two RPR port interfaces combine to support a resilient packet ring (RPR) interface. The ML-MR-10 supports only frame-mapped generic framing procedure (GFP-F) encapsulation for SONET. In addition to this, the ML-MR-10 can be configured to support up to 26 POS ports, each one terminating a SONET GFP-F encapsulated circuit.

To configure a ML-MR-10 card SONET STS circuit, refer to the “Create Circuits and Tunnels” chapter in the Cisco ONS 15454 Procedure Guide.

Cisco IOS is used to provision the Layer 2 functions of the card. The ML-MR-10 card provides management for Layer 1 operations through CTC. You can use CTM for Layer 1 and Layer 2 monitoring and fault detection, and TL1 supports card inventory and equipment alarming.

Figure 5-9 shows the ML-MR-10 card faceplate and block diagram.

Figure 5-9 ML-MR-10 Faceplate and Block Diagram

FAIL

ACT/STBY

CONSOLE

1

2

3

4

5

6

7

8

9

10

SF

TX

RX

TX

RX

TX

RX

TX

RX

TX

RX

TX

RX

TX

RX

TX

RX

TX

RX

TX

RX24

0352

Backplane

SFP

SFP

SFP

SFP

SFP

SFP

SFP

SFP

SFP

SFP

Serdes 10xGE

MAC

IngressPPE+RPR

TM+IngressPPE+RPR

TM+Queues

SDHFramer Backplane

I/F

Instruction+Statistics

MEM

MEM

Reassembly+StatisticsMEM

MEM

CPU interface10/100/1000SFPs

CPU interface

CPU

MEM

TCAM

ML-MR

10

5-23Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 24: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards 5.10.1 ML-MR-10 Card-Level Indicators

The ML-MR-10 card supports 1:1 protection at the port level. It also supports 1:1 card protection with redundant cards installed. For more information on ML-MR-10 card protection, refer to the Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration Guide.

The ML-MR-10 card supports the Version Up feature, which allows a user to independently upgrade ML-MR-10 cards as part of an overall software upgrade process. With this feature enabled, the user first upgrades all the cards in the node that are not ML-MR-10 cards, then in a second pass updates the ML-MR-10 cards. For more information on the Version Up feature, refer to the Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration Guide.

The ML-MR-10 card supports an Ethernet Virtual Connection (EVC), which is an instance of an association of two or more user network interfaces (UNI) for Ethernet services. For more information on EVC, refer to the Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration Guide.

5.10.1 ML-MR-10 Card-Level IndicatorsThe ML-MR-10 card faceplate has two card-level LED indicators, described in Table 5-23.

5.10.2 ML-MR-10 Port-Level IndicatorsThe ML-MR-10 card provides a pair of LEDs for each Ethernet port: an amber LED for activity (ACT) and a green LED for link status (LINK). Table 5-24 describes the status that each color represents.

Table 5-19 ML-MR-10 Card-Level Indicators

Card-Level LEDs Description

FAIL LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the ML-MR-10 card. As part of the boot sequence, the FAIL LED is turned on until the software deems the card operational.

ACT LED (Green) The green ACT LED provides the operational status of the ML-MR-10 card. When the ACT LED is green, it indicates that the ML-MR-10 card is active and the software is operational.

Table 5-20 ML-MR-10 Port-Level Indicators

Port-Level Indicators Description

Off No link exists to the Ethernet port.

Steady amber A link exists to the Ethernet port, but traffic flow is inhibited. For example, a lack of circuit setup, an error on the line, or a disabled port might inhibit traffic flow.

Solid green A link exists to the Ethernet port, but no traffic is carried on the port.

Flashing green A link exists to the Ethernet port, and traffic is carried on the port. The LED flash rate reflects the traffic rate for that port.

5-24Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 25: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards5.10.3 Cross-Connect and Slot Compatibility

5.10.3 Cross-Connect and Slot CompatibilityThe ML-MR-10 card can be installed in Slots 1 to 6 and 12 to 17 when used with the XC10G and XC-VXC-10G cards. It is not compatible with the XCVT card.

Caution Fan-tray assembly 15454-CC-FTA (ANSI shelf) must be installed in a shelf where an ML-MR-10 card is installed.

5.10.4 ML-MR-10 Card-Differential Delay The differential delay has been hardcoded to 55ms for high-order circuits in high speed slots and 175ms for low-order circuits in high speed slots. For all other slots and circuit combinations, it has been hardcoded to 135ms.

5.11 CE-100T-8 Card

Note For hardware specifications, see the “A.7.6 CE-100T-8 Card Specifications” section on page A-51.

The CE-100T-8 card provides eight RJ-45 10/100 Mbps Ethernet ports and an RJ-45 console port on the card faceplate. The CE-100T-8 card provides mapping of 10/100 Mbps Ethernet traffic into SONET STS-12 payloads, making use of low-order (VT1.5) virtual concatenation, high-order (STS-1) virtual concatenation, GFP, and point-to-point protocol/high-level data link control (PPP/HDLC) framing protocols.

The CE-100T-8 card also supports the link capacity adjustment scheme (LCAS), which allows hitless dynamic adjustment of SONET link bandwidth. The CE-100T-8 card’s LCAS is hardware-based, but the CE-100T-8 also supports SW-LCAS. This makes it compatible with the ONS 15454 SDH ML-Series card, which supports only SW-LCAS and does not support the standard hardware-based LCAS. SW-LCAS is supported when a circuit from the CE-100T-8 terminates on the ONS 15454 SDH ML-Series card.

Note The SW-LCAS is not supported on CE-100T-8 cards for interoperation with the CE-MR-10, CE-MR-6, and ML-MR-10 cards.

The circuit types supported are:

• HO-CCAT

• LO-VCAT with no HW-LCAS

• LO-VCAT with HW-LCAS

• STS-1-2v SW-LCAS with ML only

Each 10/100 Ethernet port can be mapped to a SONET channel in increments of VT1.5 or STS-1 granularity, allowing efficient transport of Ethernet and IP over the SONET infrastructure.

Figure 5-10 shows the CE-100T-8 card faceplate and block diagram.

5-25Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 26: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards 5.11 CE-100T-8 Card

Figure 5-10 CE-100T-8 Faceplate and Block Diagram

The following paragraphs describe the general functions of the CE-100T-8 card and relate to the block diagram.

In the ingress direction, (Ethernet-to-SONET), the PHY, which performs all of the physical layer interface functions for 10/100 Mbps Ethernet, sends the frame to the network processor for queuing in the respective packet buffer memory. The network processor performs packet processing, packet switching, and classification. The Ethernet frames are then passed to the Ethermap where Ethernet traffic is terminated and is encapsulated using HDLC or GFP framing on a per port basis. The encapsulated Ethernet frames are then mapped into a configurable number of virtual concatenated low and high order payloads, such as VT1.5 synchronous payload envelope (SPE), STS-1 SPE, or a contiguous concatenated payload such as STS-3c SPE. Up to 64 VT1.5 SPEs or 3 STS-1 SPEs can be virtually concatenated. The SONET SPE carrying encapsulated Ethernet frames are passed onto the qMDM FPGA, where four STS-3 frames are multiplexed to form a STS-12 frame for transport over the SONET network by means of the Bridging Convergence Transmission (BTC) ASIC.

In the Egress direction (SONET-to-Ethernet), the FPGA extracts four STS-3 SPEs from the STS-12 frame it receives from the BTC and sends each of the STS-3s to the ET3 mappers. The STS-3 SONET SPE carrying GFP or PPP/HDLC encapsulated Ethernet frames is then extracted and buffered in Ethermap’s external memory. This memory is used for providing alignment and differential delay compensation for the received low-order and high-order virtual concatenated payloads. After alignment and delay compensation have been done, the Ethernet frames are decapsulated with one of the framing protocols (GFP or HDLC). Decapsulated Ethernet frames are then passed onto the network processor for QoS queuing and traffic scheduling. The network processor switches the frame to one of the corresponding PHY channels and then to the Ethernet port for transmission to the external client(s).

CE100T8

FAIL

ACT

CONSOLE

1

2

3

4

5

6

7

8

1343

66

Packet Buffer3x0.5MB

Control Mem1x2MB

ETS#1

SDRAM

qMDMFPGA

PacketProcessor/

Switch Fabric qMDM

FPGA

OctalPHY

SMII8

8x10/100BaseT

RJ45

Part of qMDM FPGA FCC3

SMII

MII

4 SMII

STS3

STS3

STS3

ETS#2

SDRAM

SDRAM

STS3

SCC1

60x

Flash8MB

SDRAM128MB

CPLD

SDRAM

1

4 SMII

ETS#3

4 SMII

STS12

Add_Bus

Drop_Bus

ETS#4

3 SMII

BTC

CPU

nVRAM

Backplane

Option

5-26Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 27: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards5.11.1 CE-100T-8 Card-Level Indicators

For information on the CE-100T-8 QoS features, refer to the “CE-100T-8 Operations” chapter of the Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration Guide.

5.11.1 CE-100T-8 Card-Level IndicatorsThe CE-100T-8 card faceplate has two card-level LED indicators, described in Table 5-21.

5.11.2 CE-100T-8 Port-Level IndicatorsThe CE-100T-8 card has two LEDs embedded into each of the eight Ethernet port RJ-45 connectors. The LEDs are described in Table 5-22.

5.11.3 Cross-Connect and Slot CompatibilityThe CE-100T-8 card is compatible in Slots 1 to 6 or 12 to 17 with the XC10G, XC-VXC-10G, or XCVT cards.

5.12 CE-1000-4 Card

Note For hardware specifications, see the “A.7.5 CE-1000-4 Card Specifications” section on page A-50.

Table 5-21 CE-100T-8 Card-Level Indicators

Card-Level LEDs Description

SF LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the CE-100T-8 card. As part of the boot sequence, the FAIL LED is turned on until the software deems the card operational.

ACT LED (Green) The green ACT LED provides the operational status of the CE-100T-8. When the ACT LED is green, it indicates that the CE-100T-8 card is active and the software is operational.

Table 5-22 CE-100T-8 Port-Level Indicators

Port-Level Indicators Description

ACT LED (Amber) A steady amber LED indicates a link is detected, but there is an issue inhibiting traffic. A blinking amber LED means traffic flowing.

LINK LED (Green) A steady green LED indicates that a link is detected, but there is no traffic. A blinking green LED flashes at a rate proportional to the level of traffic being received and transmitted over the port.

Both ACT and LINK LED OFF

Unlit green and amber LEDs indicate no traffic.

5-27Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 28: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards 5.12 CE-1000-4 Card

The CE-1000-4 card uses pluggable GBICs to transport Ethernet traffic over a SONET network. The CE-1000-4 provides four IEEE 802.3-compliant, 1000-Mbps Gigabit Ethernet ports at the ingress. At the egress, the CE-1000-4 card provides an integrated Ethernet over SONET mapper with four virtual ports to transfer Ethernet packets over a SONET network.

The Ethernet ports automatically configure to operate at either half or full duplex and can determine whether to enable or disable flow control. The Ethernet ports can also be oversubscribed using flow control.

The Ethernet frames are encapsulated using the ITU-T generic framing procedure (GFP) (with or without CRC) or LEX, the point-to-point protocol (PPP) with high-level data link control (HDLC). The CE-1000-4 card can interoperate with G1K-4 cards (using LEX encapsulation), CE-100T-8 cards (using LEX or GFP-F), and ML-Series cards (using LEX or GFP-F).

The Ethernet frames can be mapped into:

• T1X1 G.707-based high-order virtual concatenated (HO VCAT) payloads:

– STS-3c

– STS-1

• Contiguously concatenated (CCAT) SONET payloads:

– Standard CCAT sizes (STS-1, STS-3c, STS-12c, STS-24c, STS-48c)

– Non-standard CCAT sizes (STS-6c, STS-9c, STS-18c).

To configure a CE-1000-4 card SONET STS or VCAT circuit, refer to the “Create Circuits and Tunnels” chapter in the Cisco ONS 15454 Procedure Guide.

The CE-1000-4 card provides multiple management options through Cisco Transport Controller (CTC), Cisco Transport Manager (CTM), Transaction Language 1 (TL1), and Simple Network Management Protocol (SNMP).

The CE-1000-4 card supports the software link capacity adjustment scheme (SW-LCAS). This makes it compatible with the ONS 15454 CE-100T-8 and ML-Series cards. The CE-1000-4 card supports VCAT groups (VCGs) that are reconfigurable when SW-LCAS is enabled (flexible VCGs). The CE-1000-4 card does not support the standard hardware-based LCAS.

The following guidelines apply to flexible VCGs:

• Members can be added or removed from VCGs.

• Members can be put into or out of service.

• Cross-connects can be added or removed from VCGs.

• Errored members will be automatically removed from VCGs.

• Adding or removing members from the VCG is service affecting.

• Adding or removing cross connects from the VCG is not service affecting if the associated members are not in group.

The CE-1000-4 card supports a non link capacity adjustment scheme (no-LCAS). This also makes it compatible with the ONS 15454 CE-100T-8 and ML-Series cards. The CE-1000-4 card supports VCAT groups (VCGs) that are fixed and not reconfigurable when no-LCAS is enabled (fixed VCGs).

The following guidelines apply to fixed VCGs:

• Members can be added or removed from VCGs using CTC or TL1.

• Members cannot be put into or out of service unless the force command mode is instantiated.

5-28Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 29: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards5.12.1 CE-1000-4 Card-Level Indicators

Note This is possible with CTC as it assumes the force command mode by default. However, to put members into or out of service using TL1, the force command mode must be set.

• Cross-connects can be added or removed from VCGs using CTC or TL1. This is service affecting as long as the VCG size (TXCOUNT) is not realigned with the loss of connections.

The CE-1000-4 card supports VCAT differential delay and provides these associated features:

• Supports a maximum VCG differential delay of 122 ms in each direction.

• Supports all protection schemes (path protection, two-fiber BLSR, four-fiber BLSR) on VCAT circuits that are split-fiber routed.

• Supports 2-fiber on VCAT circuits that are common-fiber routed.

• Differential delay compensation is automatically enabled on VCAT circuits that are diverse (split fiber) routed and disabled on VCAT circuits that are common-fiber routed.

Figure 5-11 shows the CE-1000-4 card faceplate and block diagram.

Figure 5-11 CE-1000-4 Faceplate and Block Diagram

5.12.1 CE-1000-4 Card-Level IndicatorsThe CE-1000-4 card faceplate has two card-level LED indicators, described in Table 5-23.

14

52

31

1

Rx

Tx

2

Rx

Tx

4

Rx

Tx

3

Rx

Tx

FAIL

ACT

CE-1000-4

ACT/LNK

ACT/LNK

ACT/LNK

ACT/LNK

4 ports:GigE

GBIC

GBIC

GBIC

GBIC

SERDES

CLOCK Generation

SERDES

SERDES

SERDESTADMMalena FPGA

Altera

8260 Processor, SDRAMFlash and DecodePLD

50MHz,100Mhz125Mhz,155MHz

BUFFERMEMORY

CDRFramer

QuicksilverFPGA

BTC192

POWER5V, 3.3V, 2.5V, 1.8V, -1.7V -48V

Diff.Delay.Mem.

Main RXBPIA

ProtectTX BPIA

ProtectRX BPIA

Main TXBPIA

STS48BACKPLANE

Interface

5-29Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 30: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards 5.12.2 CE-1000-4 Port-Level Indicators

Note If the CE-1000-4 card is inserted in a slot that has been preprovisioned for a different type of card, the red FAIL LED and the green ACT LED will flash alternately until the configuration mismatch is resolved.

5.12.2 CE-1000-4 Port-Level IndicatorsThe CE-1000-4 card provides a pair of LEDs for each Gigabit Ethernet port: an amber LED for activity (ACT) and a green LED for link status (LINK). Table 5-24 describes the status that each color represents.

5.12.3 Cross-Connect and Slot CompatibilityThe CE-1000-4 card can be installed in Slots 1 to 6 and 12 to 17 when used with the XC10G and XC-VXC-10G cards. When the shelf uses the XCVT card, the CE-1000-4 card can only be installed in Slots 5, 6, 12, and 13.

5.13 CE-MR-10 Card

Note For hardware specifications, see the “A.7.7 CE-MR-10 Card Specifications” section on page A-51.

Table 5-23 CE-1000-4 Card-Level Indicators

Card-Level LEDs Description

FAIL LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the CE-1000-4 card. As part of the boot sequence, the FAIL LED is turned on until the software deems the card operational.

ACT LED (Green) The green ACT LED provides the operational status of the CE-1000-4 card. When the ACT LED is green, it indicates that the CE-1000-4 card is active and the software is operational.

Table 5-24 CE-1000-4 Port-Level Indicators

Port-Level Indicators Description

Off No link exists to the Ethernet port.

Steady amber A link exists to the Ethernet port, but traffic flow is inhibited. For example, a lack of circuit setup, an error on the line, or a disabled port might inhibit traffic flow.

Solid green A link exists to the Ethernet port, but no traffic is carried on the port.

Flashing green A link exists to the Ethernet port, and traffic is carried on the port. The LED flash rate reflects the traffic rate for that port.

5-30Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 31: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards5.13 CE-MR-10 Card

The CE-MR-10 card provides ten IEEE 802.3-compliant 10/100/1000-Mbps Gigabit Ethernet ports at the ingress. At the egress, the CE-MR-10 card provides an integrated Ethernet-over-SONET mapper with ten virtual ports to transfer Ethernet packets over a SONET network.

The CE-MR-10 card uses pluggable SFPs to transport Ethernet traffic over a SONET network. SFP modules are offered as separate orderable products for flexibility. For details, see the “5.14 Ethernet Card GBICs and SFPs” section on page 5-34.

The Ethernet frames are encapsulated using the ITU-T generic framing procedure (GFP) (with or without CRC) or LEX, the Point-to-Point Protocol (PPP) with high-level data link control (HDLC).

The Ethernet ports automatically configure to operate at either half or full duplex and can determine whether to enable or disable flow control. The Ethernet ports can also be oversubscribed using flow control.

The CE-MR-10 card supports the link capacity adjustment scheme (LCAS), which allows hitless dynamic adjustment of SONET link bandwidth. The CE-MR-10 card's LCAS is hardware-based, but the CE-MR-10 also supports software LCAS (SW-LCAS). This makes it compatible with ML-Series cards, which support only SW-LCAS, along with G-Series and CE-Series cards. The CE-MR-10 card also supports the non link capacity adjustment scheme (non-LCAS). The CE-MR-10 card supports both flexible and fixed VCAT groups (VCG).

Note The SW-LCAS is not supported on CE-MR-10 cards for interoperation with the CE-100T-8 and ML-MR-10 cards.

Note The CE-MR-10 card does not support interoperation between the LCAS and non-LCAS circuits.

The Ethernet frames can be mapped into:

• T1X1 G.707-based high-order virtual concatenated (HO VCAT) payloads

– STS-3c-nv, where n is 1 to 7

– STS-1-nv, where n is 1 to 21

• T1X1 G.707-based low-order virtual concatenated (LO VCAT) payloads

– VT1.5-nv, where n is 1 to 64

• Contiguously concatenated (CCAT) SONET payloads

– Standard CCAT sizes (STS-1, STS-3c, STS-12c, STS-24c, and STS-48c)

– Non-standard CCAT sizes (STS-6c and STS-9c)

To configure a CE-MR-10 card circuit, refer to the “Create Circuits and Tunnels” chapter in the Cisco ONS 15454 Procedure Guide.

The CE-MR-10 card provides multiple management options through CTC, CTM, TL1, and SNMP.

Figure 5-12 shows the CE-MR-10 card faceplate and block diagram.

5-31Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 32: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards 5.13.1 CE-MR-10 Card-Level Indicators

Figure 5-12 CE-MR-10 Faceplate and Block Diagram

Note The backplane capacity of the CE-MR-10 card is 10 Gigabit Ethernet ports in slots 5, 6, 12, and 13 and 2.5 Gigabit Ethernet ports in slots 1 to 4 and 14 to 17.

5.13.1 CE-MR-10 Card-Level IndicatorsThe CE-MR-10 card faceplate has two card-level LED indicators, described in Table 5-25.

1597

24

Marvell10GMAC

MV8211935mm

SP14

FCC (2x)

SP14

SP14

MP41FPGA

Backplane

BCM5482SPHY

SFP

SFP

SFP

SFP

SFP

SFP

SFP

SFP

SFP

SFP

BCM5482SPHY

BCM5482SPHY

BCM5482SPHY

BCM5482SPHY

FCC (2x)

SP14

MPC8555Subsystem

SuperCarreraASIC

MEM QDR21Mx36

IBPIA

IBPIA

MP4EFPGA

MEM QDR21Mx36

MEM

RLDRAM28Mx36

MEMRLDRAM28Mx36

FAIL

ACT

LINK

ACT

TX

1

RX

LINK

ACT

TX

2

RX

LINK

ACT

TX

3

RX

LINK

ACT

TX

4

RX

LINK

ACT

TX

5

RX

LINK

ACT

TX

6

RX

LINK

ACT

TX

7

RX

LINK

ACT

TX

8

RX

LINK

ACT

TX

9

RX

LINK

ACT

TX

10

RX

CE-MR

10

5-32Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 33: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards5.13.2 CE-MR-10 Port-Level Indicators

5.13.2 CE-MR-10 Port-Level IndicatorsThe CE-MR-10 card provides a pair of LEDs for each port: an amber LED for activity (ACT) and a green LED for link status (LINK).

Table 5-26 describes the status that each color represents.

5.13.3 Cross-Connect and Slot CompatibilityThe CE-MR-10 card can be installed in Slots 1 to 6 and 12 to 17 when used with the XC10G and XC-VXC-10G cards. It is not compatible with the XVT card.

Caution Fan-tray assembly 15454-CC-FTA (ANSI shelf) must be installed in a shelf where a CE-MR-10 card is installed.

5.13.4 CE-MR-10 Card- Differential Delay The differential delay has been hardcoded to 55ms for high-order circuits in high speed slots and 175ms for low-order circuits in high speed slots. For all other slots and circuit combinations, it has been hardcoded to 135ms.

Table 5-25 CE-MR-10 Card-Level Indicators

Card-Level LEDs Description

FAIL LED (Red) The red FAIL LED indicates that the card processor is not ready or that a catastrophic software failure occurred on the card. As part of the boot sequence, the FAIL LED is turned on until the software deems the card operational.

ACT LED (Green) The green ACT LED provides the operational status of the CE-1000-4 card. When the ACT LED is green, it indicates that the CE-1000-4 card is active and the software is operational.

Table 5-26 CE-MR-10 Port-Level Indicators

Port-Level Indicators Description

Off No link exists to the Ethernet port.

Steady amber A link exists to the Ethernet port, but traffic flow is inhibited. For example, a lack of circuit setup, an error on the line, or a disabled port might inhibit traffic flow.

Solid green A link exists to the Ethernet port, but no traffic is carried on the port.

Flashing green A link exists to the Ethernet port, and traffic is carried on the port. The LED flash rate reflects the traffic rate for that port.

5-33Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 34: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards 5.14 Ethernet Card GBICs and SFPs

5.14 Ethernet Card GBICs and SFPsThis section describes the GBICs and SFPs used with the Ethernet cards.

The ONS 15454 Ethernet cards use industry standard SFPs and GBIC modular receptacles. The ML-MR-10, ML100X-8, ML1000-2, and CE-MR-10 cards use standard Cisco SFPs. The Gigabit E-Series, G-1K-4, and CE-1000-4 cards use standard Cisco GBICs. With Software Release 4.1 and later, G-Series cards can also be equipped with dense wavelength division multiplexing (DWDM) and coarse wavelength division multiplexing (CWDM) GBICs to function as Gigabit Ethernet transponders.

For all Ethernet cards, the type of GBIC or SFP plugged into the card is displayed in CTC and TL1. Cisco offers SFPs and GBICs as separate orderable products.

5.14.1 Compatibility by CardTable 5-27 shows the GBICs for the E1000-2-G, G1K-4, or CE-1000-4 cards.

Note The GBICs are very similar in appearance. Check the GBIC label carefully before installing it.

Table 5-28 shows the available SFPs and XFPs for Ethernet cards.

Table 5-27 Available GBICs

GBICAssociated Cards Application Fiber Product Number

1000BASE-SX

E1000-2-GG1K-4CE-1000-4

Short reach Multimode fiber up to 550 m long

15454E-GBIC-SX=15454-GBIC-SXONS-GC-GE-SX

1000BASE-LX

E1000-2-GG1K-4 CE-1000-4

Long reach Single-mode fiber up to 5 km long

15454E-GBIC-LX=15454-GBIC-LXONS-GC-GE-LX

1000BASE-ZX

G1K-4 CE-1000-4

Extra long reach Single-mode fiber up to 70 km long

15454E-GBIC-ZX=15454-GBIC-ZXONS-GC-GE-ZX

Table 5-28 Available SFPs and XFPs

SFP/XFPAssociated Cards Application Fiber Product Number

1000BASE-SX ML1000-2 Short reach Multimode fiber up to 550 m long

ONS-SC-GE-SX

ML1000-2ML-MR-10CE-MR-10

Short reach 850 nm multimode fiber up to 500 m long

ONS-SI-GE-SX

5-34Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 35: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards5.14.2 Speed-Duplex Combinations on SFPs

5.14.2 Speed-Duplex Combinations on SFPsTable 5-29 through Table 5-33 provides information on the speed-duplex combination supported on different SFP types for ML-MR-10 and CE-MR-10 cards.

1000BASE-LX ML1000-2 Long reach Single-mode fiber up to 5 km long

ONS-SC-GE-LX

ML1000-2ML-MR-10CE-MR-10

Long reach 1310 nm single-mode fiber up to 10 km long

ONS-SI-GE-LX

1000BASE-ZX ML1000-2ML-MR-10CE-MR-10

Extra long reach 1550 nm single-mode fiber

ONS-SI-GE-ZX

100BASE-FX ML100X-8 Short reach 1310 nm multimode fiber up to 2 km long

ONS-SE-100-FX

ML100X-8ML-MR-10CE-MR-10

Short reach 1310 nm multimode fiber

ONS-SI-100-FX

100BASE-LX10 ML100X-8 Long reach 1310 nm single-mode fiber

ONS-SE-100-LX10

ML100X-8ML-MR-10CE-MR-10

Long reach 1310 nm single-mode fiber

ONS-SI-100-LX10

10/100/1000BASE-T

ML-MR-10CE-MR-10

Short reach RJ45 ONS-SE-ZE-EL

100BASE-BX ML100X-8ML-MR-10CE-MR-10

Short reach 1550 nm RX ONS-SE-100-BX10U

100BASE-BX ML100X-8ML-MR-10CE-MR-10

Short reach 1310 nm RX ONS-SE-100-BX10D

E1/DS1 over Fast Ethernet

ML-MR-10CE-MR-10

— — ONS-SC-E1-T1-PW(Release 9.2 only)

E3/DS3 PDH over Fast Ethernet

ML-MR-10CE-MR-10

— — ONS-SC-E3-T3-PW(Release 9.2 only)

Table 5-28 Available SFPs and XFPs (continued)

SFP/XFPAssociated Cards Application Fiber Product Number

Table 5-29 Speed-Duplex Matrix for Electrical 10/100/1000Base-T SFPs

Speed ConfigurationDuplex Configuration(Y- Supported, N-Not supported)

Full Half Auto

5-35Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 36: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards 5.14.2 Speed-Duplex Combinations on SFPs

10 Mbps Y Y Y

100 Mbps Y Y Y

1000 Mbps Y N Y

Auto Y Y Y

Table 5-29 Speed-Duplex Matrix for Electrical 10/100/1000Base-T SFPs

Table 5-30 Speed-Duplex Matrix for Optical 1000BaseSX/LX/ZX SFPs

Speed ConfigurationDuplex Configuration(Y- Supported, N-Not supported)

Full Half Auto

10 Mbps N N N

100 Mbps N N N

1000 Mbps Y N Y

Auto Y N Y

Table 5-31 Speed-Duplex Matrix for Optical 100Base FX/LX10/BX-D/BX-U SFPs

Speed ConfigurationDuplex Configuration(Y- Supported, N-Not supported)

Full Half Auto

10 Mbps N N N

100 Mbps Y N N

1000 Mbps N N N

Auto N N N

Table 5-32 Speed-Duplex Matrix for E1/DS1 over Fast Ethernet SFP

Speed ConfigurationDuplex Configuration(Y- Supported, N-Not supported)

Full Half Auto

10 Mbps N N N

100 Mbps Y N N

1000 Mbps N N N

Auto N N N

5-36Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 37: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards5.14.3 GBIC Description

5.14.3 GBIC DescriptionGBICs are integrated fiber optic transceivers that provide high-speed serial links from a port or slot to the network. Various latching mechanisms can be utilized on the GBIC pluggable modules. There is no correlation between the type of latch and the model type (such as SX or LX/LH) or technology type (such as Gigabit Ethernet). See the label on the GBIC for technology type and model. One GBIC model has two clips (one on each side of the GBIC) that secure the GBIC in the slot on the Ethernet card; the other has a locking handle. Both types are shown in Figure 5-13.

GBIC dimensions are:

• Height 0.39 in. (1 cm)

• Width 1.18 in. (3 cm)

• Depth 2.56 in. (6.5 cm)

GBIC temperature ranges are:

• COM—Commercial operating temperature range –5 degrees C to 70 degrees C (23 degrees F to 158 degrees F)

• EXT—Extended operating temperature range –5 degrees C to 85 degrees C (23 degrees F to 185 degrees F)

• IND—Industrial operating temperature range –40 degrees C to 85 degrees C (-40 degrees F to 185 degrees F)

Figure 5-13 GBICs with Clips (left) and with a Handle (right)

Table 5-33 Speed-Duplex Matrix for E3/DS3 PDH over Fast Ethernet SFP

Speed ConfigurationDuplex Configuration(Y- Supported, N-Not supported)

Full Half Auto

10 Mbps N N N

100 Mbps Y N N

1000 Mbps N N N

Auto N N N

ReceiverClip

HandleTransmitter Receiver

Transmitter 5117

8

5-37Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 38: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards 5.14.4 G1K-4 DWDM and CWDM GBICs

5.14.4 G1K-4 DWDM and CWDM GBICs DWDM (15454-GBIC-xx.x, 15454E-GBIC-xx.x) and CWDM (15454-GBIC-xxxx, 15454E-GBIC-xxxx) GBICs operate in an ONS 15454 G-Series card when the card is configured in Gigabit Ethernet Transponding mode or in Ethernet over SONET mode. DWDM and CWDM GBICs are both wavelength division multiplexing (WDM) technologies and operate over single-mode fibers with SC connectors. Cisco CWDM GBIC technology uses a 20 nm wavelength grid and Cisco ONS 15454 DWDM GBIC technology uses a 1 nm wavelength grid. CTC displays the specific wavelengths of the installed CWDM or DWDM GBICs. DWDM wavelengths are spaced closer together and require more precise lasers than CWDM. The DWDM spectrum allows for optical signal amplification. For more information on G-Series card transponding mode, refer to the Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration Guide.

The DWDM and CWDM GBICs receive across the full 1300 nm and 1500 nm bands, which includes all CWDM, DWDM, LX/LH, ZX wavelengths, but transmit on one specified wavelength. This capability can be exploited in some of the G-Series transponding modes by receiving wavelengths that do not match the specific transmission wavelength.

Note G1K-4 cards with the Common Language Equipment Identification (CLEI) code of WM5IRWPCAA (manufactured after August 2003) support CWDM and DWDM GBICs. G1K-4 cards manufactured prior to August 2003 do not support CWDM or DWDM GBICs.

The ONS 15454-supported CWDM GBICs reach up to 100 to 120 km over single-mode fiber and support eight wavelengths as shown in Table 5-34.

The ONS 15454-supported DWDM GBICs reach up to 100 to 120 km over single-mode fiber and support 32 different wavelengths in the red and blue bands. Paired with optical amplifiers, such as the Cisco ONS 15216, the DWDM GBICs allow maximum unregenerated spans of approximately 300 km (Table 5-35).

CWDM or DWDM GBICs for the G-Series card come in set wavelengths and are not provisionable. The wavelengths are printed on each GBIC, for example, CWDM-GBIC-1490. The user must insert the specific GBIC transmitting the wavelength required to match the input of the CWDM/DWDM device for successful operation (Figure 5-14). Follow your site plan or network diagram for the required wavelengths.

Table 5-34 Supported Wavelengths for CWDM GBICs

CWDM GBIC Wavelengths 1470 nm 1490 nm 1510 nm 1530 nm 1550 nm 1570 nm 1590 nm 1610 nm

Corresponding GBIC Colors Gray Violet Blue Green Yellow Orange Red Brown

Band 47 49 51 53 55 57 59 61

Table 5-35 Supported Wavelengths for DWDM GBICs

Blue Band 1530.33 nm 1531.12 nm 1531.90 nm 1532.68 nm 1534.25 nm 1535.04 nm 1535.82 nm 1536.61 nm

1538.19 nm 1538.98 nm 1539.77 nm 1540.56 nm 1542.14 nm 1542.94 nm 1543.73 nm 1544.53 nm

Red Band 1546.12 nm 1546.92 nm 1547.72 nm 1548.51 nm 1550.12 nm 1550.92 nm 1551.72 nm 1552.52 nm

1554.13 nm 1554.94 nm 1555.75 nm 1556.55 nm 1558.17 nm 1558.98 nm 1559.79 nm 1560.61 nm

5-38Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 39: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards5.14.5 SFP Description

Figure 5-14 CWDM GBIC with Wavelength Appropriate for Fiber-Connected Device

A G-Series card equipped with CWDM or DWDM GBICs supports the delivery of unprotected Gigabit Ethernet service over Metro DWDM (Figure 5-15). It can be used in short-haul and long-haul applications.

Figure 5-15 G-Series with CWDM/DWDM GBICs in Cable Network

5.14.5 SFP DescriptionSFPs are integrated fiber-optic transceivers that provide high-speed serial links from a port or slot to the network. Various latching mechanisms can be utilized on the SFP modules. There is no correlation between the type of latch and the model type (such as SX or LX/LH) or technology type (such as Gigabit Ethernet). See the label on the SFP for technology type and model. One type of latch available is a mylar tab (Figure 5-16), a second type of latch available is an actuator/button (Figure 5-17), and a third type of latch is a bail clasp (Figure 5-18).

SFP dimensions are:

• Height 0.03 in. (8.5 mm)

FAIL

ACT

G1K

RX

1

TX

RX

2

TX

RX

3

TX

RX

4

TX

ACT/LINK

ACT/LINK

ACT/LINK

ACT/LINK

CWDM Mux

1470-nm Input

CWDM-GBIC-1470

9095

7

Fiber Optic Connection

CWDM/DWDM Mux only

ONS Nodewith G-Series Cards

with CWDM/DWDM GBICs

QAM

9095

4VoD

HFC

Conventional GigE signals

CWDM/DWDM Demux only

GigE / GigE /

GigE over 's

= Lambdas

5-39Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1

78-19870-01

Page 40: Chapter 5, Ethernet Cards - Cisco · CHAPTER 5-1 Cisco ONS 15454 Reference Manual, Releases 9.1, 9.2, and 9.2.1 78-19870-01 5 Ethernet Cards Note The terms “Unidirectional Path

Chapter 5 Ethernet Cards 5.14.5 SFP Description

• Width 0.53 in. (13.4 mm)

• Depth 2.22 in. (56.5 mm)

SFP temperature ranges for are:

• COM—Commercial operating temperature range –5 degrees C to 70 degrees C (23 degrees F to 158 degrees F)

• EXT—Extended operating temperature range –5 degrees C to 85 degrees C (23 degrees F to 185 degrees F)

• IND—Industrial operating temperature range –40 degrees C to 85 degrees C (-40 degrees F to 185 degrees F)