TSN19301-1 Rev.1 - Page 1 28th October, 2019
MODELSNEPTUNE KEYPAD TOUCH EM/HID S/ALONE or WIEGAND IP65 (2x6) ACKPWST
PROGRAMMING
ENTER PROGRAMMING MODE
* <MASTER CODE> # (default 888888)
CHANGE MASTER CODE
0
<NEW MASTER CODE> # <REPEAT> #
ADD PIN USERS
1
<USER NUMBER (1-2000)> #
<PIN NUMBER> #
1
2
3
1
2
MASTER CODE MUST BE BETWEEN 6-8 DIGITS.PRESS * TO EXIT PROGRAMMING
ADDITIONAL USERS CAN BE ADDED BY REPEATING STEPS 2 & 3
EXAMPLE1 1 # 9384 # 2 # 2958 # 3 # 9876 # *
The programming above added 3 users with unique pin numbers
PIN NUMBERS MUST BE BETWEEN 4-6 DIGITSPRESS * TO EXIT PROGRAMMING
ADD CARD USERS
1
<USER NUMBER (1-2000)> #
<BADGE CARD>
1
2
3
ADDITIONAL USERS CAN BE ADDED BY REPEATING STEPS 2 & 3
EXAMPLE1 1 # <BADGE CARD> 2 # <BADGE CARD> *
The programming above added 2 users with cards
THE ABOVE METHOD IS PREFERRED FOR CARD PROGRAMMINGSO INSTALLERS CAN NOTE WHICH USER NUMBER EACH CARD
IS ASSIGNED TO.PRESS * TO EXIT PROGRAMMING
DELETE USERS BY USER NUMBER
2
<USER NUMBER (1-2000)> #
1
2
ALL USERS CAN BE DELETED USING THE FOLLOWING STEPS
PIN NUMBERS MUST BE BETWEEN 4-6 DIGITSPRESS * TO EXIT PROGRAMMING
2
0000 #
1
2
SET DOOR RELAY TIME
4
0 # (50ms / 5 seconds) DEFAULT1 - 99 # (Another time in seconds)
1
2
PRESS * TO EXIT PROGRAMMING
DELETE USERS BY CARD
2
<BADGE CARD>
1
2
THSI METHOD REQUIRES EXISTING CARD TO BE PRESENTPRESS * TO EXIT PROGRAMMING
ADD CARD USERS WITH MANAGER CARDS
<BADGE MANAGER ADD CARD>
<BADGE USER CARD BEING ADDED>
1
2
<BADGE MANAGER ADD CARD>3
THIS METHOD DOES NOT REQUIRE PROGRAMMING MODEMETHOD IS IDENTICAL FOR DELETING USERS WITH MANAGER CARD
Colour Indicators refer to LED status lights on Keypad
NEPTUNE Quick Reference Guide
TSN19301-1 Rev.1 - Page 2 28th October, 2019
NEPTUNE Quick Reference Guide
PROGRAMMING (Advanced)
SET TO WIEGAND/STANDALONE MODE
71
WIEGAND: FOR CONNECTION TO EXTERNAL ACCESS CONTROL SYSTEMPRESS ** TO EXIT PROGRAMMING
1
0 # (Wiegand)1 # (Standalone) DEFAULT
2
3
SET WIEGAND FORMAT
71
APPLICABLE WHEN IN WIEGAND MODEPRESS ** TO EXIT PROGRAMMING
2
26 - 37 # (26bit to 37bit Wiegand Output)DEFAULT - 26bit Wiegand
2
3
SET KEYPAD TRANMISSION FORMAT
71
APPLICABLE WHEN IN WIEGAND MODEPRESS ** TO EXIT PROGRAMMING
3
0 # Buffered Output1 # 4bit Burst DEFAULT2 # 8bit Burst
2
3
TURN INDICATOR LIGHT ON/OFF
81
THIS IS IN REFERENCE TO THE LED LIGHT ABOVE THE KEYPADPRESS ** TO EXIT PROGRAMMING
1
0 # (Off)1 # (On) DEFAULT
2
3
DISABLE/ENABLE KEYPAD BUZZER
81
KEYPAD BUZZER WILL STILL OCCUR DURING PROGRAMMING MODEPRESS ** TO EXIT PROGRAMMING
2
0 # (Disable)1 # (Enable) DEFAULT
2
3
DISABLE/ENABLE KEYPAD BACKLIGHT
81
PRESS ** TO EXIT PROGRAMMING
3
0 # (Disable)1 # (Enable) DEFAULT
2
3
USER OPERATION
Additional programming options available in User Manual
Successful Command (Long Beep)
Unsuccessful Command (3 Short Beeps)
USER ENTRY
User Presents Card, orEnters Pin Number #
CHANGING EXISTING USER PIN
* <USER NUMBER> <CURRENT PIN> #
<NEW PIN> # <NEW PIN> # Valid Access (Long Beep)LED stays green on for relay time
Access Denied (3 Short Beeps) Successful Command
TSN19301-1 Rev.1 - Page 3 28th October, 2019
NEPTUNE Quick Reference Guide
POWER SUPPLY
+-
+
-
12VDC (Red)
GND (Black)
COM (Purple)
NC (Orange)
OPEN (Yellow)
NEPANOB
ACKPWST
12VDC
FEM3500 *
POWER SUPPLY
+-
+
-
12VDC (Red)
GND (Black)
COM (Purple)
NO (Blue)
OPEN (Yellow)
NEPANOB
ACKPWST
12VDC
FES20 *
Power to Open (Normally Open)
Power to Lock (Normally Closed)
STANDALONE WIRING EXAMPLES
For connection to Access Control Panel (must be set to Wiegand mode)WIEGAND WIRING EXAMPLE
12VDC (Red)
GND (Black)
ACKPWST
D0 (Green)
D1 (White)
LED (Brown)
BUZZER (Yellow)BUZZER
LED
D1
D0
GND
+12VDC
ACCESSCONTROL
PANEL