CHAMPA FLATS CHAMPA STREET ALLEY PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ® 11/21/2017 3:41:59 PM B I M 3 6 0 : / / C h a m p a F l a t s / 1 1 6 1 4 5 . 0 0 C h a m p a F l a t s C & S _ A 1 8 _ C e n t r a l . r v t 1/8" = 1'-0" CHAMPA FLATS 2250 CHAMPA STREET, DENVER CO 80205 116145.00 OZ OZ 2017/11/08 SCHEMATIC DESIGN SITE PLAN A-100 CHAMPA FLATS Approver 1/8" = 1'-0" 1 SITE PLAN TRUE NORTH PROJECT NORTH 0' 4' 8' 16' 32' EXISTING BILLBOARD STAIR TRANSFORMER AT GRADE ELEVATOR AND STAIR OVERRUN UNIT ROOF DECKS AT LEVEL 4 TENANT AMENITY DECK AT LEVEL 4 PARKING GARAGE ENTRANCE/EXIT 2' EASEMENT 0' SETBACK 0' SETBACK 10' UPPER SETBACK 0' SETBACK AT GRADE 8' TREE LAWN ±20' PRORERTY LINE TO CURB DROP-OFF FOR RIDE-SHARING AND TAXI 10' STREET TREES IN TREE LAWN, PAVER GRATE, OR PLANTER 125.08 ZONE LOT WIDTH' MIN. 8' SIDEWALK MAIN BUILDING ENTRY

CHAMPA FLATS - Denver plan a-100 champa flats approver 1/8" = 1'-0" 1 site plan true north project north 0' 4' 8' 16' 32' existing billboard ... 14 see sheet a-600 for door schedule

  • Upload
    letuyen

  • View
    217

  • Download
    4

Embed Size (px)

Citation preview

CHAMPA FLATS

CHAMPA STREET

ALLEY

PROJ. NO.

DRAWN:

CHECKED:

DATE:

© OZ ARCHITECTURE

SCALE:

SHEET NUMBER

SHEET TITLE:

ISSUED FOR:

APPROVED:

3003 Larimer Street

Denver, Colorado 80205

phone 303.861.5704

www.ozarch.com

ARCHITECTURE®

11

/21/2

01

7 3

:41

:59

PM

BIM

36

0://C

ha

mp

a F

lats

/11

614

5.0

0 C

ha

mpa F

lats

C&

S_A

18

_C

en

tra

l.rv

t

1/8" = 1'-0"

CH

AM

PA

FLA

TS

22

50

CH

AM

PA

ST

RE

ET

, D

EN

VE

R C

O 8

02

05

116145.00

OZ

OZ

2017/11/08

SCHEMATIC DESIGN

SITE PLAN

A-100

CHAMPA FLATS

Approver

1/8" = 1'-0"1

SITE PLAN

TRUE

NORTH

PROJECT

NORTH

0' 4' 8' 16' 32'

EXISTINGBILLBOARD

STAIR

TRANSFORMERAT GRADE

ELEVATOR ANDSTAIR OVERRUN

UNIT ROOF DECKSAT LEVEL 4

TENANT AMENITYDECK AT LEVEL 4

PARKINGGARAGE

ENTRANCE/EXIT

2' EASEMENT

0' SETBACK

0' SETBACK

10' UPPER SETBACK

0' SETBACKAT GRADE

8' TREE LAWN

±20'

PR

OR

ER

TY

LIN

E T

O C

UR

B

DROP-OFF FORRIDE-SHARING AND TAXI

10'

STREET TREES IN TREE LAWN,PAVER GRATE, OR PLANTER

125.08 ZONE LOT WIDTH'

MIN. 8' SIDEWALK

MAIN BUILDING ENTRY

UP

UP

1

A-201

1

A-204

1

A-203

1

A-202

GA

G1.1 G2 G3 G4 G5 G6 G7

GB

GC

GD

GE

GF

A

C

F

L

P

3

17 1815

4

120' - 1"

11

8' -

8"

2' - 0" 14' - 1" 28' - 0" 16' - 0" 16' - 0" 28' - 0" 16' - 0"

17

' -

4"

25

' -

4"

27

' -

0"

27

' -

0"

22

' -

0"

1

A-301

1

A-302

STAIR 2

ST2

GARAGE

001

ST2-L0.5

D

ELEVATOR PIT

EV

G1

G1

1

2' - 0"

14

E

EXISTING WALL

NEW WALL

FLOOR PLAN LEGEND

AREA NOT IN CONTRACT

PROJ. NO.

DRAWN:

CHECKED:

DATE:

© OZ ARCHITECTURE

SCALE:

SHEET NUMBER

SHEET TITLE:

ISSUED FOR:

APPROVED:

3003 Larimer Street

Denver, Colorado 80205

phone 303.861.5704

www.ozarch.com

ARCHITECTURE®

11

/21/2

01

7 3

:42

:01

PM

BIM

36

0://C

ha

mp

a F

lats

/11

614

5.0

0 C

ha

mpa F

lats

C&

S_A

18

_C

en

tra

l.rv

t

1/8" = 1'-0"

CH

AM

PA

FLA

TS

22

50

CH

AM

PA

ST

RE

ET

, D

EN

VE

R C

O 8

02

05

116145.00

OZ

OZ

2017/11/08

SCHEMATIC DESIGN

SUB-LEVEL 1 - FLOORPLAN

A-100B

CHAMPA FLATS

Approver

FLOOR PLAN NOTES1 EL.100'-0" (LEVEL 1) EQUATES TO USGS DATUM ELEVATION OF ______.

2 EXTERIOR DIMENSIONS ARE TO FACE OF SHEATHING, FACE OFCONCRETE/MASONRY, COLUMN CENTERLINE, OR CENTERLINE OF WINDOWU.N.O.

3 INTERIOR DIMENSIONS ARE TO FACE OF STUD, FACE OFCONCRETE/MASONRY, OR COLUMN CENTERLINE U.N.O. DIMENSIONSDESIGNATED AS "CLEAR" OR "HOLD" SHALL BE MAINTAINED.

4 SEE SHEET G-503 FOR PARTITION TYPES. SEE CODE PLANS, G-100 SERIESSHEETS, FOR RATINGS OF PARTITIONS. METAL STUD PARTITIONS ARE TYPE23C, U.N.O. WOOD STUD PARTITIONS ARE TYPE W24C U.N.O.

5 PARTITION TYPES INDICATED CONTINUE AROUND CORNERS U.N.O.

6 MAINTAIN CONTINUITY OF RATED PARTITIONS AT HEAD AND BOTTOM OFPARTITION AND AT JOINTS WITH DISSIMILAR PARTITIONS WITH LISTED JOINTASSEMBLIES.

7 WHERE TWO DIFFERING PARTITION TYPES ABUT ALONG A CONTINUOUS LINE,THE CONTINUOUS FINISHED SURFACE OF THESE PARTITIONS SHALL ALIGNU.N.O.

8 WHERE DOORS ARE NOT SPECIFICALLY LOCATED, PROVIDE A HINGE-SIDEJAMB DIMENSION OF 4" FROM DOOR OPENING TO ADJACENTPERPENDICULAR PARTITION.

9 WHERE MECHANICAL DUCTWORK PENETRATES A COMPONENT OF THEFIRE-RATED ASSEMBLY, PROVIDE FIRE AND/OR SMOKE DAMPERS INACCORDANCE WITH IBC CHAPTER 7.

10 PROVIDE 1/2" CLEARANCE FROM DUCTWORK FOR VIBRATION ISOLATION.

11 THERE SHALL BE NO EXPOSED PIPES, DUCTS, ETC. ALL SUCH LINES SHALLBE CONCEALED OR FURRED UNLESS SPECIFICALLY NOTED AS EXPOSEDCONSTRUCTION.

12 FIELD VERIFY DIMENSIONS PRIOR TO FABRICATION OF CASEWORK,MILLWORK AND OTHER BUILT-IN ITEMS.

13 SEE SHEET G-401 FOR MOUNTING HEIGHTS AND BLOCKING FOR FUTUREGRAB BARS.

14 SEE SHEET A-600 FOR DOOR SCHEDULE.

15 SEE A-700 SERIES SHEETS FOR UNIT PLANS.

PROJECT FLAGNOTES

NO. FLAGNOTE

1/8" = 1'-0"1

LOWER LEVEL PARKING

TRUE

NORTH

PROJECT

NORTH

0' 4' 8' 16' 32'

PARKING (NOT SHOWN)

DN UP

DN UP

1

A-201

1

A-204

1

A-203

1

A-202

GA

G1.1

G2

G2 G3 G4 G5 G6 G7

GB

GC

GD

GE

GF

A

C

F

L

P

3

17 1815

4

118' - 1"

11

8' -

8"

14' - 1" 28' - 0" 16' - 0" 16' - 0" 28' - 0" 16' - 0"

17

' -

4"

25

' -

4"

27

' -

0"

27

' -

0"

22

' -

0"

98

' -

0"

10

1' -

4"

1

A-301

1

A-302

ST2-L1

STAIR 2

ST2

GARAGE

101

RESIDENTIALLOBBY

102

AMENITY SPACE

103

DELEVATOR 1

EV-1

ELEVATOR 2

EV-2

G11

10" 9' - 2" 6' - 11"

16' - 1"

14

E

LOADING DOCK AREAGARAGE ENTRY

EXISTING WALL

NEW WALL

FLOOR PLAN LEGEND

AREA NOT IN CONTRACT

PROJ. NO.

DRAWN:

CHECKED:

DATE:

© OZ ARCHITECTURE

SCALE:

SHEET NUMBER

SHEET TITLE:

ISSUED FOR:

APPROVED:

3003 Larimer Street

Denver, Colorado 80205

phone 303.861.5704

www.ozarch.com

ARCHITECTURE®

11

/21/2

01

7 3

:42

:04

PM

BIM

36

0://C

ha

mp

a F

lats

/11

614

5.0

0 C

ha

mpa F

lats

C&

S_A

18

_C

en

tra

l.rv

t

1/8" = 1'-0"

CH

AM

PA

FLA

TS

22

50

CH

AM

PA

ST

RE

ET

, D

EN

VE

R C

O 8

02

05

116145.00

OZ

OZ

2017/11/08

SCHEMATIC DESIGN

LEVEL 1 FLOOR PLAN

A-101

CHAMPA FLATS

Approver

1/8" = 1'-0"1

LEVEL 1 FLOOR PLAN

FLOOR PLAN NOTES1 EL.100'-0" (LEVEL 1) EQUATES TO USGS DATUM ELEVATION OF ______.

2 EXTERIOR DIMENSIONS ARE TO FACE OF SHEATHING, FACE OFCONCRETE/MASONRY, COLUMN CENTERLINE, OR CENTERLINE OF WINDOWU.N.O.

3 INTERIOR DIMENSIONS ARE TO FACE OF STUD, FACE OFCONCRETE/MASONRY, OR COLUMN CENTERLINE U.N.O. DIMENSIONSDESIGNATED AS "CLEAR" OR "HOLD" SHALL BE MAINTAINED.

4 SEE SHEET G-503 FOR PARTITION TYPES. SEE CODE PLANS, G-100 SERIESSHEETS, FOR RATINGS OF PARTITIONS. METAL STUD PARTITIONS ARE TYPE23C, U.N.O. WOOD STUD PARTITIONS ARE TYPE W24C U.N.O.

5 PARTITION TYPES INDICATED CONTINUE AROUND CORNERS U.N.O.

6 MAINTAIN CONTINUITY OF RATED PARTITIONS AT HEAD AND BOTTOM OFPARTITION AND AT JOINTS WITH DISSIMILAR PARTITIONS WITH LISTED JOINTASSEMBLIES.

7 WHERE TWO DIFFERING PARTITION TYPES ABUT ALONG A CONTINUOUS LINE,THE CONTINUOUS FINISHED SURFACE OF THESE PARTITIONS SHALL ALIGNU.N.O.

8 WHERE DOORS ARE NOT SPECIFICALLY LOCATED, PROVIDE A HINGE-SIDEJAMB DIMENSION OF 4" FROM DOOR OPENING TO ADJACENTPERPENDICULAR PARTITION.

9 WHERE MECHANICAL DUCTWORK PENETRATES A COMPONENT OF THEFIRE-RATED ASSEMBLY, PROVIDE FIRE AND/OR SMOKE DAMPERS INACCORDANCE WITH IBC CHAPTER 7.

10 PROVIDE 1/2" CLEARANCE FROM DUCTWORK FOR VIBRATION ISOLATION.

11 THERE SHALL BE NO EXPOSED PIPES, DUCTS, ETC. ALL SUCH LINES SHALLBE CONCEALED OR FURRED UNLESS SPECIFICALLY NOTED AS EXPOSEDCONSTRUCTION.

12 FIELD VERIFY DIMENSIONS PRIOR TO FABRICATION OF CASEWORK,MILLWORK AND OTHER BUILT-IN ITEMS.

13 SEE SHEET G-401 FOR MOUNTING HEIGHTS AND BLOCKING FOR FUTUREGRAB BARS.

14 SEE SHEET A-600 FOR DOOR SCHEDULE.

15 SEE A-700 SERIES SHEETS FOR UNIT PLANS.

PROJECT FLAGNOTES

NO. FLAGNOTE

TRUE

NORTH

PROJECT

NORTH

0' 4' 8' 16' 32'

MAIN BUILDING ENTRY

CHAMPA STREET

ALLEY

TRANSFORMERAT GRADE

0' SETBACK;FIRE-RATED

EXTERIOR WALL

0' SETBACK;FIRE-RATED

EXTERIOR WALL

ELEVATOR LOBBYMAIN LOBBYRETAIL / COMMERCIAL

DN UP

DN UP

1

A-201

1

A-204

1

A-203

1

A-202

GA

G1.1 G2 G3 G4 G5 G6 G7

GB

GC

GD

GE

GF

A

C

F

L

P

3

17 1815

4

120' - 1"

11

8' -

8"

2' - 0" 14' - 1" 28' - 0" 16' - 0" 16' - 0" 28' - 0" 16' - 0"

17

' -

4"

25

' -

4"

27

' -

0"

27

' -

0"

22

' -

0"

10

1' -

4"

1

A-301

1

A-302

ST2-L2

STAIR 2

ST2

GARAGE

201

LOBBY MEZZANINE

104

OPEN TO BELOW

D

1' - 1"

ELEVATOR 1

EV-1

ELEVATOR 2

EV-2

G1

1

2' - 0"

14

E

EXISTING WALL

NEW WALL

FLOOR PLAN LEGEND

AREA NOT IN CONTRACT

PROJ. NO.

DRAWN:

CHECKED:

DATE:

© OZ ARCHITECTURE

SCALE:

SHEET NUMBER

SHEET TITLE:

ISSUED FOR:

APPROVED:

3003 Larimer Street

Denver, Colorado 80205

phone 303.861.5704

www.ozarch.com

ARCHITECTURE®

11

/21/2

01

7 3

:42

:06

PM

BIM

36

0://C

ha

mp

a F

lats

/11

614

5.0

0 C

ha

mpa F

lats

C&

S_A

18

_C

en

tra

l.rv

t

1/8" = 1'-0"

CH

AM

PA

FLA

TS

22

50

CH

AM

PA

ST

RE

ET

, D

EN

VE

R C

O 8

02

05

116145.00

OZ

OZ

2017/11/08

SCHEMATIC DESIGN

LEVEL 2 FLOOR PLAN

A-102

CHAMPA FLATS

Approver

FLOOR PLAN NOTES1 EL.100'-0" (LEVEL 1) EQUATES TO USGS DATUM ELEVATION OF ______.

2 EXTERIOR DIMENSIONS ARE TO FACE OF SHEATHING, FACE OFCONCRETE/MASONRY, COLUMN CENTERLINE, OR CENTERLINE OF WINDOWU.N.O.

3 INTERIOR DIMENSIONS ARE TO FACE OF STUD, FACE OFCONCRETE/MASONRY, OR COLUMN CENTERLINE U.N.O. DIMENSIONSDESIGNATED AS "CLEAR" OR "HOLD" SHALL BE MAINTAINED.

4 SEE SHEET G-503 FOR PARTITION TYPES. SEE CODE PLANS, G-100 SERIESSHEETS, FOR RATINGS OF PARTITIONS. METAL STUD PARTITIONS ARE TYPE23C, U.N.O. WOOD STUD PARTITIONS ARE TYPE W24C U.N.O.

5 PARTITION TYPES INDICATED CONTINUE AROUND CORNERS U.N.O.

6 MAINTAIN CONTINUITY OF RATED PARTITIONS AT HEAD AND BOTTOM OFPARTITION AND AT JOINTS WITH DISSIMILAR PARTITIONS WITH LISTED JOINTASSEMBLIES.

7 WHERE TWO DIFFERING PARTITION TYPES ABUT ALONG A CONTINUOUS LINE,THE CONTINUOUS FINISHED SURFACE OF THESE PARTITIONS SHALL ALIGNU.N.O.

8 WHERE DOORS ARE NOT SPECIFICALLY LOCATED, PROVIDE A HINGE-SIDEJAMB DIMENSION OF 4" FROM DOOR OPENING TO ADJACENTPERPENDICULAR PARTITION.

9 WHERE MECHANICAL DUCTWORK PENETRATES A COMPONENT OF THEFIRE-RATED ASSEMBLY, PROVIDE FIRE AND/OR SMOKE DAMPERS INACCORDANCE WITH IBC CHAPTER 7.

10 PROVIDE 1/2" CLEARANCE FROM DUCTWORK FOR VIBRATION ISOLATION.

11 THERE SHALL BE NO EXPOSED PIPES, DUCTS, ETC. ALL SUCH LINES SHALLBE CONCEALED OR FURRED UNLESS SPECIFICALLY NOTED AS EXPOSEDCONSTRUCTION.

12 FIELD VERIFY DIMENSIONS PRIOR TO FABRICATION OF CASEWORK,MILLWORK AND OTHER BUILT-IN ITEMS.

13 SEE SHEET G-401 FOR MOUNTING HEIGHTS AND BLOCKING FOR FUTUREGRAB BARS.

14 SEE SHEET A-600 FOR DOOR SCHEDULE.

15 SEE A-700 SERIES SHEETS FOR UNIT PLANS.

PROJECT FLAGNOTES

NO. FLAGNOTE

1/8" = 1'-0"1

LEVEL 2 FLOOR PLAN

TRUE

NORTH

PROJECT

NORTH

0' 4' 8' 16' 32'

PARKING (NOT SHOWN)

DN

UP

DN

UP

1

A-201

1

A-204

1

A-203

1

A-202

GA

G1.1 G2 G3 G4 G5 G6 G7

GB

GC

GD

GE

GF

A

C

F

L

P

3

17 1815

4

118' - 1"

11

8' -

8"

14' - 1" 28' - 0" 16' - 0" 16' - 0" 28' - 0" 16' - 0"

17

' -

4"

25

' -

4"

27

' -

0"

27

' -

0"

22

' -

0"

10

1' -

4"

1

A-301

1

A-302

ST2-L3STAIR 2

ST2

GARAGE

301

AMENITY

303

DELEVATOR 1

EV-1

ELEVATOR 2

EV-2

G1

1

14

E

EXISTING WALL

NEW WALL

FLOOR PLAN LEGEND

AREA NOT IN CONTRACT

PROJ. NO.

DRAWN:

CHECKED:

DATE:

© OZ ARCHITECTURE

SCALE:

SHEET NUMBER

SHEET TITLE:

ISSUED FOR:

APPROVED:

3003 Larimer Street

Denver, Colorado 80205

phone 303.861.5704

www.ozarch.com

ARCHITECTURE®

11

/21/2

01

7 3

:42

:09

PM

BIM

36

0://C

ha

mp

a F

lats

/11

614

5.0

0 C

ha

mpa F

lats

C&

S_A

18

_C

en

tra

l.rv

t

1/8" = 1'-0"

CH

AM

PA

FLA

TS

22

50

CH

AM

PA

ST

RE

ET

, D

EN

VE

R C

O 8

02

05

116145.00

OZ

OZ

2017/11/08

SCHEMATIC DESIGN

LEVEL 3 FLOOR PLAN

A-103

CHAMPA FLATS

Approver

FLOOR PLAN NOTES1 EL.100'-0" (LEVEL 1) EQUATES TO USGS DATUM ELEVATION OF ______.

2 EXTERIOR DIMENSIONS ARE TO FACE OF SHEATHING, FACE OFCONCRETE/MASONRY, COLUMN CENTERLINE, OR CENTERLINE OF WINDOWU.N.O.

3 INTERIOR DIMENSIONS ARE TO FACE OF STUD, FACE OFCONCRETE/MASONRY, OR COLUMN CENTERLINE U.N.O. DIMENSIONSDESIGNATED AS "CLEAR" OR "HOLD" SHALL BE MAINTAINED.

4 SEE SHEET G-503 FOR PARTITION TYPES. SEE CODE PLANS, G-100 SERIESSHEETS, FOR RATINGS OF PARTITIONS. METAL STUD PARTITIONS ARE TYPE23C, U.N.O. WOOD STUD PARTITIONS ARE TYPE W24C U.N.O.

5 PARTITION TYPES INDICATED CONTINUE AROUND CORNERS U.N.O.

6 MAINTAIN CONTINUITY OF RATED PARTITIONS AT HEAD AND BOTTOM OFPARTITION AND AT JOINTS WITH DISSIMILAR PARTITIONS WITH LISTED JOINTASSEMBLIES.

7 WHERE TWO DIFFERING PARTITION TYPES ABUT ALONG A CONTINUOUS LINE,THE CONTINUOUS FINISHED SURFACE OF THESE PARTITIONS SHALL ALIGNU.N.O.

8 WHERE DOORS ARE NOT SPECIFICALLY LOCATED, PROVIDE A HINGE-SIDEJAMB DIMENSION OF 4" FROM DOOR OPENING TO ADJACENTPERPENDICULAR PARTITION.

9 WHERE MECHANICAL DUCTWORK PENETRATES A COMPONENT OF THEFIRE-RATED ASSEMBLY, PROVIDE FIRE AND/OR SMOKE DAMPERS INACCORDANCE WITH IBC CHAPTER 7.

10 PROVIDE 1/2" CLEARANCE FROM DUCTWORK FOR VIBRATION ISOLATION.

11 THERE SHALL BE NO EXPOSED PIPES, DUCTS, ETC. ALL SUCH LINES SHALLBE CONCEALED OR FURRED UNLESS SPECIFICALLY NOTED AS EXPOSEDCONSTRUCTION.

12 FIELD VERIFY DIMENSIONS PRIOR TO FABRICATION OF CASEWORK,MILLWORK AND OTHER BUILT-IN ITEMS.

13 SEE SHEET G-401 FOR MOUNTING HEIGHTS AND BLOCKING FOR FUTUREGRAB BARS.

14 SEE SHEET A-600 FOR DOOR SCHEDULE.

15 SEE A-700 SERIES SHEETS FOR UNIT PLANS.

PROJECT FLAGNOTES

NO. FLAGNOTE

1/8" = 1'-0"1

LEVEL 3 FLOOR PLAN

TRUE

NORTH

PROJECT

NORTH

0' 4' 8' 16' 32'

PARKING (NOT SHOWN)

FITNESS / AMENITY

UP

DN

DN

UP

1

A-201

1

A-204

1

A-203

1

A-202

A

C

F

G G

H

J J

K

L

M

P

5

3

7 9

8

11 12 13

16

17

18

1815

16

' -

0"

2' -

0"

26

' -

0"

28

' -

0"

14' - 0" 14' - 0" 14' - 0" 14' - 0" 14' - 0" 14' - 0" 16' - 0" 10' - 0" 10' - 0"

28

' -

0"

6' -

0"

14

' -

0"

14

' -

0"

14

' -

0"

14

' -

0"

6' -

0"

14

' -

0"

10' - 0" 2' - 0" 12' - 0" 14' - 0"

2

B

122' - 0"

120' - 0"

4

11

0' -

0"

10

50' - 0" 18' - 0"

72

' -

0"

1

A-301

1

A-302

ST2-L4

STAIR 2

ST2

STORAGE

409

TRASH

411

UNIT A

424

UNIT A1

417

AMENITY

415

UNIT C

407

UNIT A

405

UNIT C

403

UNIT C

401

UNIT A

408

UNIT A

410

UNIT A

412

UNIT A

414

UNIT A

416

CORRIDOR

400

UNIT A

418

UNIT A

420

UNIT A

422

UNIT A2

404

UNIT A

406

MECHANICALROOM

402

D

ELEVATOR 2

EV-2

ELEVATOR 1

EV-1

1 6

IT/JC

419

14

E

EXISTING WALL

NEW WALL

FLOOR PLAN LEGEND

AREA NOT IN CONTRACT

PROJ. NO.

DRAWN:

CHECKED:

DATE:

© OZ ARCHITECTURE

SCALE:

SHEET NUMBER

SHEET TITLE:

ISSUED FOR:

APPROVED:

3003 Larimer Street

Denver, Colorado 80205

phone 303.861.5704

www.ozarch.com

ARCHITECTURE®

11

/21/2

01

7 3

:42

:12

PM

BIM

36

0://C

ha

mp

a F

lats

/11

614

5.0

0 C

ha

mpa F

lats

C&

S_A

18

_C

en

tra

l.rv

t

1/8" = 1'-0"

CH

AM

PA

FLA

TS

22

50

CH

AM

PA

ST

RE

ET

, D

EN

VE

R C

O 8

02

05

116145.00

OZ

OZ

2017/11/08

SCHEMATIC DESIGN

LEVEL 4 FLOOR PLAN

A-104

CHAMPA FLATS

Approver

FLOOR PLAN NOTES1 EL.100'-0" (LEVEL 1) EQUATES TO USGS DATUM ELEVATION OF ______.

2 EXTERIOR DIMENSIONS ARE TO FACE OF SHEATHING, FACE OFCONCRETE/MASONRY, COLUMN CENTERLINE, OR CENTERLINE OF WINDOWU.N.O.

3 INTERIOR DIMENSIONS ARE TO FACE OF STUD, FACE OFCONCRETE/MASONRY, OR COLUMN CENTERLINE U.N.O. DIMENSIONSDESIGNATED AS "CLEAR" OR "HOLD" SHALL BE MAINTAINED.

4 SEE SHEET G-503 FOR PARTITION TYPES. SEE CODE PLANS, G-100 SERIESSHEETS, FOR RATINGS OF PARTITIONS. METAL STUD PARTITIONS ARE TYPE23C, U.N.O. WOOD STUD PARTITIONS ARE TYPE W24C U.N.O.

5 PARTITION TYPES INDICATED CONTINUE AROUND CORNERS U.N.O.

6 MAINTAIN CONTINUITY OF RATED PARTITIONS AT HEAD AND BOTTOM OFPARTITION AND AT JOINTS WITH DISSIMILAR PARTITIONS WITH LISTED JOINTASSEMBLIES.

7 WHERE TWO DIFFERING PARTITION TYPES ABUT ALONG A CONTINUOUS LINE,THE CONTINUOUS FINISHED SURFACE OF THESE PARTITIONS SHALL ALIGNU.N.O.

8 WHERE DOORS ARE NOT SPECIFICALLY LOCATED, PROVIDE A HINGE-SIDEJAMB DIMENSION OF 4" FROM DOOR OPENING TO ADJACENTPERPENDICULAR PARTITION.

9 WHERE MECHANICAL DUCTWORK PENETRATES A COMPONENT OF THEFIRE-RATED ASSEMBLY, PROVIDE FIRE AND/OR SMOKE DAMPERS INACCORDANCE WITH IBC CHAPTER 7.

10 PROVIDE 1/2" CLEARANCE FROM DUCTWORK FOR VIBRATION ISOLATION.

11 THERE SHALL BE NO EXPOSED PIPES, DUCTS, ETC. ALL SUCH LINES SHALLBE CONCEALED OR FURRED UNLESS SPECIFICALLY NOTED AS EXPOSEDCONSTRUCTION.

12 FIELD VERIFY DIMENSIONS PRIOR TO FABRICATION OF CASEWORK,MILLWORK AND OTHER BUILT-IN ITEMS.

13 SEE SHEET G-401 FOR MOUNTING HEIGHTS AND BLOCKING FOR FUTUREGRAB BARS.

14 SEE SHEET A-600 FOR DOOR SCHEDULE.

15 SEE A-700 SERIES SHEETS FOR UNIT PLANS.

PROJECT FLAGNOTES

NO. FLAGNOTE

1/8" = 1'-0"1

LEVEL 4 FLOOR PLAN

TRUE

NORTH

PROJECT

NORTH

0' 4' 8' 16' 32'

TENANT AMENITY ROOFDECK AT LEVEL 4

TENANTAMENITYKITCHEN /LOUNGE

UNIT ROOF DECKSAT LEVEL 4

DN UP

DNUP

1

A-201

1

A-204

1

A-203

1

A-202

A

C

F

G G

H

J J

K

L

M

P

5

3

7 9

8

11 12 13

16

17

18

18152

B

4 10

16

' -

0"

2' -

0"

26

' -

0"

28

' -

0"

14' - 0" 14' - 0" 14' - 0" 14' - 0" 14' - 0" 14' - 0" 16' - 0" 10' - 0" 10' - 0"

28

' -

0"

6' -

0"

14

' -

0"

14

' -

0"

14

' -

0"

14

' -

0"

6' -

0"

14

' -

0"

10' - 0" 2' - 0" 12' - 0" 14' - 0"

122' - 0"

120' - 0"

11

0' -

0"

50' - 0" 18' - 0"

72

' -

0"

1

A-301

1

A-302

ST2-L5

STAIR 2

ST2

STORAGE

509

TRASH

511

UNIT A

524

UNIT A1

517

UNIT A1

515

UNIT C

507

UNIT A

505

UNIT C

503

UNIT C

501

UNIT A

508

UNIT A

510

UNIT A

512

UNIT A

514

UNIT A

516

CORRIDOR

500

UNIT A

518

UNIT A

520

UNIT A

522

UNIT A2

504

UNIT A

506

MECHANICALROOM

502

D

ELEVATOR 2

EV-2

ELEVATOR 1

EV-1

1 6

IT/JC

519

14

E

EXISTING WALL

NEW WALL

FLOOR PLAN LEGEND

AREA NOT IN CONTRACT

PROJ. NO.

DRAWN:

CHECKED:

DATE:

© OZ ARCHITECTURE

SCALE:

SHEET NUMBER

SHEET TITLE:

ISSUED FOR:

APPROVED:

3003 Larimer Street

Denver, Colorado 80205

phone 303.861.5704

www.ozarch.com

ARCHITECTURE®

11

/21/2

01

7 3

:42

:15

PM

BIM

36

0://C

ha

mp

a F

lats

/11

614

5.0

0 C

ha

mpa F

lats

C&

S_A

18

_C

en

tra

l.rv

t

1/8" = 1'-0"

CH

AM

PA

FLA

TS

22

50

CH

AM

PA

ST

RE

ET

, D

EN

VE

R C

O 8

02

05

116145.00

OZ

OZ

2017/11/08

SCHEMATIC DESIGN

LEVEL 5-13 FLOORPLAN

A-105

CHAMPA FLATS

Approver

FLOOR PLAN NOTES1 EL.100'-0" (LEVEL 1) EQUATES TO USGS DATUM ELEVATION OF ______.

2 EXTERIOR DIMENSIONS ARE TO FACE OF SHEATHING, FACE OFCONCRETE/MASONRY, COLUMN CENTERLINE, OR CENTERLINE OF WINDOWU.N.O.

3 INTERIOR DIMENSIONS ARE TO FACE OF STUD, FACE OFCONCRETE/MASONRY, OR COLUMN CENTERLINE U.N.O. DIMENSIONSDESIGNATED AS "CLEAR" OR "HOLD" SHALL BE MAINTAINED.

4 SEE SHEET G-503 FOR PARTITION TYPES. SEE CODE PLANS, G-100 SERIESSHEETS, FOR RATINGS OF PARTITIONS. METAL STUD PARTITIONS ARE TYPE23C, U.N.O. WOOD STUD PARTITIONS ARE TYPE W24C U.N.O.

5 PARTITION TYPES INDICATED CONTINUE AROUND CORNERS U.N.O.

6 MAINTAIN CONTINUITY OF RATED PARTITIONS AT HEAD AND BOTTOM OFPARTITION AND AT JOINTS WITH DISSIMILAR PARTITIONS WITH LISTED JOINTASSEMBLIES.

7 WHERE TWO DIFFERING PARTITION TYPES ABUT ALONG A CONTINUOUS LINE,THE CONTINUOUS FINISHED SURFACE OF THESE PARTITIONS SHALL ALIGNU.N.O.

8 WHERE DOORS ARE NOT SPECIFICALLY LOCATED, PROVIDE A HINGE-SIDEJAMB DIMENSION OF 4" FROM DOOR OPENING TO ADJACENTPERPENDICULAR PARTITION.

9 WHERE MECHANICAL DUCTWORK PENETRATES A COMPONENT OF THEFIRE-RATED ASSEMBLY, PROVIDE FIRE AND/OR SMOKE DAMPERS INACCORDANCE WITH IBC CHAPTER 7.

10 PROVIDE 1/2" CLEARANCE FROM DUCTWORK FOR VIBRATION ISOLATION.

11 THERE SHALL BE NO EXPOSED PIPES, DUCTS, ETC. ALL SUCH LINES SHALLBE CONCEALED OR FURRED UNLESS SPECIFICALLY NOTED AS EXPOSEDCONSTRUCTION.

12 FIELD VERIFY DIMENSIONS PRIOR TO FABRICATION OF CASEWORK,MILLWORK AND OTHER BUILT-IN ITEMS.

13 SEE SHEET G-401 FOR MOUNTING HEIGHTS AND BLOCKING FOR FUTUREGRAB BARS.

14 SEE SHEET A-600 FOR DOOR SCHEDULE.

15 SEE A-700 SERIES SHEETS FOR UNIT PLANS.

PROJECT FLAGNOTES

NO. FLAGNOTE

1/8" = 1'-0"1

LEVEL 5-13 FLOOR PLAN

TRUE

NORTH

PROJECT

NORTH

0' 4' 8' 16' 32'

DN

DN

1

A-201

1

A-204

1

A-203

1

A-202

A

C

F

G G

H

J J

K

L

M

P

5

3

7 9

8

11 12 13

16

17

18

18152

B

4 10

16

' -

0"

28

' -

0"

28

' -

0"

14' - 0" 14' - 0" 14' - 0" 14' - 0" 14' - 0" 14' - 0" 16' - 0" 10' - 0" 10' - 0"

28

' -

0"

6' -

0"

14

' -

0"

14

' -

0"

14

' -

0"

14

' -

0"

6' -

0"

14

' -

0"

10' - 0" 2' - 0"

10' - 0" 112' - 0"

120' - 0"

11

0' -

0"

50' - 0" 18' - 0"

72

' -

0"

1

A-301

1

A-302

ST2-R

ST1-R

STAIR 2

ST2

D

ELEVATOROVERRUN

R-01

MECHANICALROOM

R-02

R-02

1 6

14

E

PROJ. NO.

DRAWN:

CHECKED:

DATE:

© OZ ARCHITECTURE

SCALE:

SHEET NUMBER

SHEET TITLE:

ISSUED FOR:

APPROVED:

3003 Larimer Street

Denver, Colorado 80205

phone 303.861.5704

www.ozarch.com

ARCHITECTURE®

11

/21/2

01

7 3

:42

:18

PM

BIM

36

0://C

ha

mp

a F

lats

/11

614

5.0

0 C

ha

mpa F

lats

C&

S_A

18

_C

en

tra

l.rv

t

1/8" = 1'-0"

CH

AM

PA

FLA

TS

22

50

CH

AM

PA

ST

RE

ET

, D

EN

VE

R C

O 8

02

05

116145.00

OZ

OZ

2017/11/08

SCHEMATIC DESIGN

ROOF PLAN

A-106

CHAMPA FLATS

Approver

1/8" = 1'-0"1

ROOF PLAN

ROOF PLAN NOTES1 MAINTAIN MINIMUM SLOPE OF 1/4" PER FOOT AT ROOF AREAS (INCLUDING

CRICKETS). SLOPE VALLEYS A MINIMUM OF 1/8” PER FOOT.

2 MAINTAIN 2" MINIMUM RIGID INSULATION AT ROOF DRAINS.

3 OVERFLOW DRAINS ARE TO BE 2" ABOVE PRIMARY ROOF DRAINS U.N.O.

4 PROVIDE WALKWAY PADS BETWEEN AND AROUND MECHANICAL EQUIPMENT,ACCESS POINTS, AND WINDOW WASHING LOCATIONS.

5 SEE SHEET ____ FOR TYPICAL ROOF DETAILS.

PROJECT FLAGNOTES

NO. FLAGNOTE

TRUE

NORTH

PROJECT

NORTH

0' 4' 8' 16' 32'

ROOF-MOUNTED PV SYSTEM(NOT SHOWN)

2250

STUCCO COLOR 1

STUCCO COLOR 2

STUCCO COLOR 1

6' X 6' UNIT WINDOW WITH 2' OPERABLE PANEL ANDINTEGRATED PTAC GRILLE

WOOD RAINSCREEN

CHARRED WOODRAINSCREEN

STAINED WOOD SCREEN

PUBLIC BENCH

RETAIL/COMMERCIAL ENTRYMAIN BUILDING ENTRYELEVATOR LOBBY EGRESS

BIKE RACKS

STUCCO COLOR 2

FIBER CEMENT PANELSYSTEM

PARAPET TO FULL HEIGHTOF ELEVATOR OVERRUN

TENANT FITNESS CENTERAND AMENITY LEVEL

UNIT DECKS AT LEVEL 4

LEVEL 1100' - 0"

ROOF242' - 2"

LEVEL 2110' - 6"

LEVEL 3121' - 0"

LEVEL 0.589' - 6"

LEVEL 4135' - 6"

LEVEL 5146' - 2"

LEVEL 6156' - 10"

LEVEL 7167' - 6"

LEVEL 8178' - 2"

LEVEL 9188' - 10"

LEVEL 10199' - 6"

LEVEL 11210' - 2"

LEVEL 12220' - 10"

LEVEL 13231' - 6"

53 7 98 11 12 13 16 17 18152 4 10

15

2' -

6"

2' -

6"

7' -

10

"1

0' -

8"

10

' -

8"

10

' -

8"

10

' -

8"

10

' -

8"

10

' -

8"

10

' -

8"

10

' -

8"

10

' -

8"

10

' -

8"

14

' -

6"

10

' -

6"

10

' -

6"

10

' -

6"

1

A-301

1

A-302

T.O. STAIR250' - 0"

4' -

10

"

1 6 14

PROJ. NO.

DRAWN:

CHECKED:

DATE:

© OZ ARCHITECTURE

SCALE:

SHEET NUMBER

SHEET TITLE:

ISSUED FOR:

APPROVED:

3003 Larimer Street

Denver, Colorado 80205

phone 303.861.5704

www.ozarch.com

ARCHITECTURE®

11

/21/2

01

7 3

:42

:39

PM

BIM

36

0://C

ha

mp

a F

lats

/11

614

5.0

0 C

ha

mpa F

lats

C&

S_A

18

_C

en

tra

l.rv

t

1/8" = 1'-0"

CH

AM

PA

FLA

TS

22

50

CH

AM

PA

ST

RE

ET

, D

EN

VE

R C

O 8

02

05

116145.00

OZ

OZ

2017/11/08

SCHEMATIC DESIGN

BUILDING ELEVATIONS

A-201

CHAMPA FLATS

Approver

1/8" = 1'-0"1

EAST ELEVATION FACING ALLEY

NO UNIT WINDOWSFACING ALLEY; UNIT

WINDOWS FACENORTH-SOUTH

TENANT AMENITY ROOFDECK AT LEVEL 4

TRANSFORMER(OPEN TO SKY)

LEVEL 1100' - 0"

ROOF242' - 2"

LEVEL 2110' - 6"

LEVEL 3121' - 0"

LEVEL 0.589' - 6"

LEVEL 4135' - 6"

LEVEL 5146' - 2"

LEVEL 6156' - 10"

LEVEL 7167' - 6"

LEVEL 8178' - 2"

LEVEL 9188' - 10"

LEVEL 10199' - 6"

LEVEL 11210' - 2"

LEVEL 12220' - 10"

LEVEL 13231' - 6"

A C F G H J K L M PB

7' -

10

"1

0' -

8"

10

' -

8"

10

' -

8"

10

' -

8"

10

' -

8"

10

' -

8"

10

' -

8"

10

' -

8"

10

' -

8"

10

' -

8"

14

' -

6"

10

' -

6"

10

' -

6"

10

' -

6"

T.O. STAIR250' - 0"

D E

PROJ. NO.

DRAWN:

CHECKED:

DATE:

© OZ ARCHITECTURE

SCALE:

SHEET NUMBER

SHEET TITLE:

ISSUED FOR:

APPROVED:

3003 Larimer Street

Denver, Colorado 80205

phone 303.861.5704

www.ozarch.com

ARCHITECTURE®

11

/21/2

01

7 3

:42

:58

PM

BIM

36

0://C

ha

mp

a F

lats

/11

614

5.0

0 C

ha

mpa F

lats

C&

S_A

18

_C

en

tra

l.rv

t

1/8" = 1'-0"

CH

AM

PA

FLA

TS

22

50

CH

AM

PA

ST

RE

ET

, D

EN

VE

R C

O 8

02

05

116145.00

OZ

OZ

2017/11/08

SCHEMATIC DESIGN

BUILDING ELEVATIONS

A-202

CHAMPA FLATS

Approver

1/8" = 1'-0"1

SOUTH ELEVATION

PARKING GARAGEENTRANCE / EXIT

STAIR

CHAMPA STREET ALLEY

4 LE

VE

LS O

F S

TR

UC

TU

RE

D, E

NC

LOS

ED

PA

RK

ING

TENANT AMENITY

RETAIL /COMMERCIAL

UNITS AT 10' SETBACK

LEVEL 1100' - 0"

ROOF242' - 2"

LEVEL 2110' - 6"

LEVEL 3121' - 0"

LEVEL 0.589' - 6"

LEVEL 4135' - 6"

LEVEL 5146' - 2"

LEVEL 6156' - 10"

LEVEL 7167' - 6"

LEVEL 8178' - 2"

LEVEL 9188' - 10"

LEVEL 10199' - 6"

LEVEL 11210' - 2"

LEVEL 12220' - 10"

LEVEL 13231' - 6"

2' -

6"

7' -

10

"1

0' -

8"

10

' -

8"

10

' -

8"

10

' -

8"

10

' -

8"

10

' -

8"

10

' -

8"

10

' -

8"

10

' -

8"

10

' -

8"

14

' -

6"

10

' -

6"

10

' -

6"

10

' -

6"

ACFGHJKLMP B

15

2' -

6"

T.O. STAIR250' - 0"

DE

4' - 0"

PROJ. NO.

DRAWN:

CHECKED:

DATE:

© OZ ARCHITECTURE

SCALE:

SHEET NUMBER

SHEET TITLE:

ISSUED FOR:

APPROVED:

3003 Larimer Street

Denver, Colorado 80205

phone 303.861.5704

www.ozarch.com

ARCHITECTURE®

11

/21/2

01

7 3

:43

:39

PM

BIM

36

0://C

ha

mp

a F

lats

/11

614

5.0

0 C

ha

mpa F

lats

C&

S_A

18

_C

en

tra

l.rv

t

1/8" = 1'-0"

CH

AM

PA

FLA

TS

22

50

CH

AM

PA

ST

RE

ET

, D

EN

VE

R C

O 8

02

05

116145.00

Author

Checker

2017/11/08

SCHEMATIC DESIGN

BUILDING ELEVATIONS

A-204

CHAMPA FLATS

Approver

1/8" = 1'-0"1

NORTH ELEVATION

CHAMPA STREET

ALLEY

TENANT AMENITY ROOFDECK AT LEVEL 4