17
General “One-To-Many” (OTM) concept The “One-to-Many” (OTM) concept allows for a single actuator, e.g. electric motor to drive multiple independently actuated and controlled degrees of freedom (DoF). Each DoF has its own dedicated reservoir for controlled energy storage and release. Each reservoir can be actively coupled, either to the actuator to store energy or to the end-effector/load to release energy. Similar to the recruitment of muscle fibers in a biological muscle, OTM system can output variable stiffness actuation by controlling the recruitment of actuated DoFs coupled to a common load. The system is also capable of augmenting power by releasing energy over a much shorter period of time than was required to store that energy. Within OTM system, the state of each actuated DoF and the state of the actuator are all mechanically decoupled. This technology may prove critical for systems with many DoF that will benefit from being compact, lightweight, efficient, modular, and capable of variable stiffness and power augmentation. Existing examples of successfully realized OTM system include a cable driven Linear OTM utilizing linear springs [3-5] and a shaft driven Rotary OTM utilizing rotary springs [1-2]. Practical hydraulic OTM systems with fast multi-valves [6] currently under development within WPI Popovic Labs are discussed in this proposal. OTM Definition The general “One-to-Many” (OTM) concept allows for a single actuator, e.g. electric motor to drive multiple independently actuated and controlled degrees of freedom (DoF). Each DoF has its own dedicated reservoir for controlled energy storage and release. Each reservoir can be actively coupled, either to the actuator to store energy or to the end-effector/load to release energy. Hence, within OTM system, the state of each actuated DoF and the state of the actuator are all mechanically decoupled. Any system that encompasses this definition is considered an OTM system. OTM Power augmentation capability The emergent feature of any OTM system is power augmentation. The OTM system is capable of augmenting power by releasing energy over a much shorter period of time than was required to store that energy.

cga/mp/GeneralOTMforproposalwithCMU.docx · Web viewHowever, this traditional approach limits natural DoF and reduces comfort for the user. Further, misalignments between biological

Embed Size (px)

Citation preview

Page 1: cga/mp/GeneralOTMforproposalwithCMU.docx · Web viewHowever, this traditional approach limits natural DoF and reduces comfort for the user. Further, misalignments between biological

General “One-To-Many” (OTM) conceptThe “One-to-Many” (OTM) concept allows for a single actuator, e.g. electric motor to drive

multiple independently actuated and controlled degrees of freedom (DoF). Each DoF has its own dedicated reservoir for controlled energy storage and release. Each reservoir can be actively coupled, either to the actuator to store energy or to the end-effector/load to release energy. Similar to the recruitment of muscle fibers in a biological muscle, OTM system can output variable stiffness actuation by controlling the recruitment of actuated DoFs coupled to a common load. The system is also capable of augmenting power by releasing energy over a much shorter period of time than was required to store that energy. Within OTM system, the state of each actuated DoF and the state of the actuator are all mechanically decoupled. This technology may prove critical for systems with many DoF that will benefit from being compact, lightweight, efficient, modular, and capable of variable stiffness and power augmentation.

Existing examples of successfully realized OTM system include a cable driven Linear OTM utilizing linear springs [3-5] and a shaft driven Rotary OTM utilizing rotary springs [1-2]. Practical hydraulic OTM systems with fast multi-valves [6] currently under development within WPI Popovic Labs are discussed in this proposal.OTM Definition

The general “One-to-Many” (OTM) concept allows for a single actuator, e.g. electric motor to drive multiple independently actuated and controlled degrees of freedom (DoF). Each DoF has its own dedicated reservoir for controlled energy storage and release. Each reservoir can be actively coupled, either to the actuator to store energy or to the end-effector/load to release energy. Hence, within OTM system, the state of each actuated DoF and the state of the actuator are all mechanically decoupled. Any system that encompasses this definition is considered an OTM system.OTM Power augmentation capability

The emergent feature of any OTM system is power augmentation. The OTM system is capable of augmenting power by releasing energy over a much shorter period of time than was required to store that energy. This quite practical property of OTM systems may substantially lower power requirements on a single actuator for numerous applications.

Standard pneumatic and hydraulic systems typically consist of one motor actuating many DoF. Ordinarily, these systems have a single energy reservoir that is utilized more as a safety measure than as a mean to efficiently store and release energy of pressurized gasses or other elastic elements.

The OTM presented here is different from these and other approaches because the actuator is never directly connected to the load; instead, elastic or pressurized elements, one per each DoF, are used to store potential energy. When this energy is not being stored by the motor, it is passively stored until the energy is needed at the point of actuation. As a result, the power output at each DoF is not limited by the maximum output power of the motor itself.From Soft Robotics Exo-Musculature to OTM ConceptThe OTM concept was motivated by research on Soft-Robotics Exo-Musculature utilizing Bowden cable [10-13]. The goal was to design an at-home, comfortable, and portable orthotic and prosthetic (O&P) device built off of an Exo-Musculature that could assist patients in physical therapy routines and/or everyday tasks.

The term Exo-Musculature, introduced first in [4], refers to a soft, thin, light-weight, and compliant self-actuated garment without rigid elements or singular joints.

Page 2: cga/mp/GeneralOTMforproposalwithCMU.docx · Web viewHowever, this traditional approach limits natural DoF and reduces comfort for the user. Further, misalignments between biological

Traditionally, assistive or augmentative systems like orthotic or exoskeleton systems consist of rigid links and joints for the lower [21] and upper body [22] extremities. Similarly, most previous actuated systems for upper body rehabilitation use rigid exoskeletons or rigid link manipulators [23-24].

However, this traditional approach limits natural DoF and reduces comfort for the user. Further, misalignments between biological and artificial joints are inevitable [25]. Misalignments occur due to: (1) substantial skin-bone relative motion, (2) changes in volume of the limb, (3) initial imprecision when putting on the exoskeleton etc. Clearly, misalignments make exoskeletons uncomfortable and in regards to the lower extremities, can even lead to skin lesions and bone fractures due to the large forces they are subject to.

When comparing Exo-Musculatures to Exo-Skeletons, the Exo-Musculature utilizes natural anatomical structures (skeletal joints and bones) to provide support for the device and as a result, maintain natural kinematic DoF [10]. As there are no pre-specified synthetic rigid joints, an Exo-Musculature avoids misalignment problems at the joint level. Misalignments that are still present in the system are less critical and can be addressed with more advanced sensory-motor control system [13].

The more fundamental problem for mechanically actuated wearable Exo-Musculature with biologically inspired variable stiffness is need for large number of independently actuated and controlled DoF.

The force and torque produced by biological muscles can be modulated by controlling the number of fibers that are activated in parallel, a process known as recruitment [25]. This modulation of force enables optimized efficiency over a wide range of loads and contraction velocities as well as accelerations [26-28]. For the human body, there are approximately 800 skeletal muscles, each of which is composed of one hundred or more individual motor units [25]. For example, biceps brachii have about 750-800 such motor units [29-30]. Each motor unit represents a single independently actuated and controlled DoF.

Consequently, if an artificial assistive Exo-Musculature is to mimic even a small percentage of human musculature, the number of actuated DoF needs to be large. For mechanically actuated devices, conventional approaches involving one dedicated electric motor per actuated DoF results in systems that are very large, heavy, and expensive. This is clearly inappropriate for a fully mobile, wearable Exo-Musculature.

The general OTM concept solves this problem as it allows for a single actuator, e.g. electric motor to drive multiple independently actuated and controlled DoF.The OTM biologically inspired recruitment strategy

Some of the OTM actuated DoF can be coupled to the same load, performing as muscle fibers of the same muscle. Engaging simultaneously combination of those DoF provides recruitment resulting in variable stiffness performance similar to that observed in an ordinary muscle.

Hence, OTM systems are very similar to the biological architecture and dynamical performance of “muscle fibers” and muscles.The OTM system and SEAs

On a structural level, Series Elastic Actuators (SEA) [31] and single OTM “muscle fibers” are similar; however, the two are very different on operational and control levels. While both systems introduce an elastic element between the actuator and load, SEAs do not store energy in this element; rather, SEAs passively transfer energy from a single actuator onto respective load. The value of SEA is simplicity and escape from an impractically tight position control paradigm. This property is also shared by OTM system. The OTM system, similar to SEA, is not about tight position control. Unlike a SEA, the OTM system can modulate power output and it can utilize biologically inspired recruitment strategies in

Page 3: cga/mp/GeneralOTMforproposalwithCMU.docx · Web viewHowever, this traditional approach limits natural DoF and reduces comfort for the user. Further, misalignments between biological

practical manner by allowing for a single actuator to drive multiple independently actuated and controlled ‘muscle fiber” DoF.OTM architecture

On a structural level, all OTM systems consist of a single actuator coupled to DoF dedicated energy reservoirs which connect back in series with the end-effector/load, Figure 1. On an operational level, no single reservoir can be coupled to both the actuator (to store energy) and load (to release energy) at the same time. These characteristics make up the architecture of every OTM system.

As a result of this architecture, actuators are mechanically decoupled from end-effectors’ dynamics and may operate in safe and potentially close to optimal regime.

Similarly, no two DoFs share the same energy reservoir. Hence, they are all mechanically decoupled from each other. Here, it is assumed that for realistic application, two or more DoFs will be active at the same time.

Figure 1: OTM System Flowchart

Conventional pneumatic and hydraulic systems often have shared energy reservoirs. If this energy reservoir is infinitely large, its state can be considered independent of the end-effectors’ dynamics. However, for finite sized reservoirs, and in particular for very small reservoirs, the state of each reservoir depends on end-effectors’ dynamics. Hence, the end-effectors’ dynamics are not decoupled from each other. Furthermore, the actuator is not decoupled from load.

Although simple shared reservoir architectures require a smaller number of structural and sensing elements, the advantages of the OTM concept include decoupled actuator and DoFs states.

OTM systems obtain controlled energy storage and release by means of clutches, brakes, transmission mechanisms etc. for mechanical drives and valves for fluid based, i.e. pneumatic and hydraulic, drives.

The emergent feature of any OTM system is power augmentation. The OTM system is capable of augmenting power by releasing energy over a much shorter period of time than was required to store that energy. For example, imagine that a system needs to output 500 W for only 20 ms every second. Ignoring energy losses, this corresponds to at least 10 J of energy stored in an energy reservoir. During a period of 980 ms, a single actuator could store energy at rate of only 10.2 W (49 times smaller input power than output power). Gain is system that can be driven with only a tiny, light weight, inexpensive actuator and powered with a tiny electric battery.

Page 4: cga/mp/GeneralOTMforproposalwithCMU.docx · Web viewHowever, this traditional approach limits natural DoF and reduces comfort for the user. Further, misalignments between biological

Linear and Rotary OTMThe linear OTM system was the first physical realization of the basic OTM architecture. The

system was capable of storing elastic potential energy in springs through the use of a single electric motor and a sequence of active clutch mechanisms. The prototype system had a single motor connected to three independent motor units (DoF). Each motor unit consists of two clutch mechanisms and one elastic element. This allows three possible states: Charging (mechanical energy is transferred from motor to an elastic element), Neutral (energy is stored in elastic element), and finally, Release (potential energy is transferred to load). The goal of this prototype was to realize an OTM mechanism based on fast, inexpensive, lightweight, and energy efficient clutches. The solution to this was designing latching-solenoid based clutches that could axially constrain a gear and control the rotation of a spool mounted to each gear. A latching solenoid is a type of solenoid that requires an electric pulse to open or close but does not require power to remain in either state.

Figure 2 - C1, C3, C5 are the energy storage clutches. C2, C4, C6 are the energy release clutches. Input is the motor drive wheel to charge springs. E1, E2, E3, are storage springs. E4, E5, E6 are experimental load springs.

Rotary OTMThe Rotary OTM system [1-4] was built using standard OTM architecture. The primary goal

when designing this implementation was to allow for motor units (DoFs) to be compact, lightweight, energy efficient, and modular. This was realized by designing independent modules that acted as motor units.

Modules were designed to connect either to the motor or to another motor unit in series. A driveshaft running the length of the module allows for energy to be transferred through itself to another unit with minimal losses due to friction.

A planetary gear based clutch allows for the drive shaft to rotate at a constant velocity, and simultaneously allow for at least one other output at all times. This allows each motor unit to engage and disengage with the main drive shaft to transfer energy to an internal elastic element without affecting any other modules.

A few features of the Linear OTM system were improved with new Rotary OTM system. Most importantly: (1) more compact rotary spring was used instead of linear spring and (2) Rotary OTM incorporates a more refined means of a controlling the energy output of the system in order to achieve actuations that could vary in speed, force, and stiffness.

Page 5: cga/mp/GeneralOTMforproposalwithCMU.docx · Web viewHowever, this traditional approach limits natural DoF and reduces comfort for the user. Further, misalignments between biological

Figure 3: Exploded View of Clutch 1

Figure 4: Energy Storage/Release Components

Page 6: cga/mp/GeneralOTMforproposalwithCMU.docx · Web viewHowever, this traditional approach limits natural DoF and reduces comfort for the user. Further, misalignments between biological

Figure 5 - A) OTM Module (One DoF) Front, B) OTM Module (One DoF) Back, C) Two OTM modules showing how they could be connected in series (left) or to a motor using a coupling (right), D) Planetary gear set used in clutch.

Hydraulic OTMThe OTM architecture can be also realized with fluid based actuation. One example is practical

hydraulic OTM systems with fast multi-valves currently under development [6].Soft hydraulic artificial muscle array with simple sensing

The advantage of hydraulically and pneumatically actuated OTM systems is that most elements are commercially available. It is rather common for hydraulic and pneumatic systems to have a single actuator engages multiple DoF. For mechanically actuated OTM systems, the majority of components used had to be custom made.

A hydraulically actuated Exo-muscle may have several advantages over pneumatically actuated Exo-muscles. The system response times are typically much faster (sound propagates faster in water than in air), energy losses are much smaller, and for incompressible fluid forces per unit area may be much larger allowing for more compact design of system with same peak force dynamical output [32-25].

Further, The Exo-Musculature directly interfacing with human body system, consisting mostly (>60%) of water, may provide mechanically more compatible media which is often considered as an advantage [33].

The currently considered system’s actuations are those similar to conventional PAM ala McKibben muscle, dating back to 1950s where pressurizing fluid causes artificial muscle compression [34-35] and those with just opposite mechanism, such that pressurizing fluid causes artificial muscle elongation [36-37]. Later designs are similar to commercially available expandable garden hose [38]. The outer non-stretchable layer is in wrinkled state when muscle is not fully extended and it defines the maximal elongation of the muscle. Its rationale is to confine muscle stretching along axial direction. The inner layer in the form of elastic tube (e.g. latex) containing fluid returns muscle to its original state when fluid is not pressurized, Figure 6.

Page 7: cga/mp/GeneralOTMforproposalwithCMU.docx · Web viewHowever, this traditional approach limits natural DoF and reduces comfort for the user. Further, misalignments between biological

muscles muscles

energy storage energy storage

A) B)

Figure 6 - Expandable garden hose like artificial muscle

Independent of type, i.e. McKibben vs expandable hose like, hydraulic muscle can be bi-directionally controlled by controlling the pressure or total volume of stored fluid.

Another advantage of hydraulically vs. pneumatically actuated muscle is simplified integrated sensing. Pneumatically actuated muscles typically require integrated strain gauges embedded in “skin” [17] to estimate muscle length. Hydraulically actuated muscles solves that complexities by simple resistance measurements of working fluid, in this case water. It was experimentally established that resistance of water contained in muscle is fairly linear function of muscle length and may provide a good estimate of this variable [25]. Multivalve system

Imagine hydraulic system with large number of fluid powered actuated degrees freedom (DoF), Figure 7. Each actuated DoF will necessitate at least two valves to control pressure. System on the lines of the OTM concept that has separate energy storage / power augmentation unit per DoF will require at least three valves per DoF.

However, having too many valves in the system may be problematic due to cost, size, mass, and energy efficiency.

Here, this problem is addressed by exchanging the large number of conventional valves with newly designed multivalve system based on rotary disk with embedded fast valve, Figure 8.

There exists variety of similar design solution involving selective rotary disk valves for both hydraulic [39-40] and pneumatic [41] systems. For better controllability fast standard electronic valve embedded in rotary disk is anticipated.

Figure 7 - Architecture of the fluid powered Exo-Musculature system with conventional single energy reservoid(A) and with one energy reservoir per DoF on the lines of OTM systems (B).

Page 8: cga/mp/GeneralOTMforproposalwithCMU.docx · Web viewHowever, this traditional approach limits natural DoF and reduces comfort for the user. Further, misalignments between biological

fast valve

A) B) C)

R

R

RR

1-to-N multivalve consists of rotary disk with single opening embedded with fast valve (<2ms to completely close or open) and another static disc with many openings, each corresponding to one DoF. Only when rotary and static disk openings are aligned and fast valve is open fluid is allowed to flow through. Distance between rotary and static disk is much smaller compared to the diameter (~1-5 mm) of disk opening, Figure 9.

Figure 9 – Renders of proposed 1-to-N multivalve

The N-to-N multivalve, Figure 10, consists of rotary disk with single opening embedded with fast valve. Rotary disk is sandwiched with two static discs with equal number of openings, each corresponding to one of DoFs. Again, only when rotary and static disks openings are aligned and fast valve is open fluid is allowed to flow through.

Figure 8 - 1-to-N multivalve: rotary, R, and stationary disks (A), schematics (B) and cross-sectional view of embedded fast valve within the rotary disk shown next to the stationary disk opening (C).

Page 9: cga/mp/GeneralOTMforproposalwithCMU.docx · Web viewHowever, this traditional approach limits natural DoF and reduces comfort for the user. Further, misalignments between biological

fast valve

A) B) C)

RR R R

Consider regime in which rotary disk is rotating with constant angular velocity ω corresponding to period T=2 ∙ π /ω. If the angle associated with single opening is φO then angle associated with space between nearest neighbor openings for densest configuration is φO+ω∙ 2ms. This defines the maximal

number of openings as Nmax 2 ∙ π / (2 ∙ φO+ω∙2 ms ). If opening diameter is D and if opening center is

located at distance r from the center of rotary disk then φO=D /r .For example for Nmax=25 , D=5mm ,r=5 cm it follows that

ω=( π

Nmax−

Dr )

2 ms /2=25.6 rad

s=244.6 rpm

and T=245 ms corresponding to roughly 4 Hz frequency.

Hence, each DoF can be in principle actuated four times per second for roughly up to

2 ∙φO

ω=2∙ D

rω=( rπ

D Nmax−1)

−1

2 ms= 8ms each time. Details of actuation however depend on state of

the fast valve.Clear advantage of this method in the OTM case is that instead of 3 ∙ N max=75electronic valves

only 3 fast valves and 3 rotary mechanisms are required.The static disk openings are also added with passive valves similar to biological heart valves that

confine fluid when static opening is not aligned with rotary opening.

References[1] C. J. Berthelette, M. DiPinto, J. D. Sareault, (primary advisor M. B. Popovic), Rotary "One-To-Many" (OTM) Novel Actuator; The Winner of the 2013 WPI Mechanical Engineering Department Best MQP in Robotics Engineering Award. WPI, April 25, 2013.(MQP Report)

Figure 10 - N-to-N multivalve: stationary, rotary, R, and stationary disks (A), schematics (B) and cross-sectional view of embedded fast valve within the rotary disk shown sandwiched between two stationary disk openings.

Page 10: cga/mp/GeneralOTMforproposalwithCMU.docx · Web viewHowever, this traditional approach limits natural DoF and reduces comfort for the user. Further, misalignments between biological

https://www.wpi.edu/Pubs/E-project/Available/E-project-042513-153455/unrestricted/Rotary_One-to-Many_OTM_Novel_Actuator_Final_Report.pdf[2] M. B. Popovic, C. J Berthelette, M. Dipinto, J. D. Sareault, and T. R. Hunt (2013), “One-To-Many systems for electric motors”, United States Patent and Trademark Office, Assignee Worcester Polytechnic Institute, Application Number: 61844604, Filling Date: 07/10/2013, www.USPTO.gov .[3] T. R. Hunt, C. J. Berthelette, G. S. Iannacchione, S. Koehler, and M. B. Popovic, "Soft Robotics Variable Stiffness Exo-Musculature, One-To-Many Concept, and Advanced Clutches", IEEE ICRA 2012 WORKSHOP: Variable Stiffness Actuators moving the Robots of Tomorrow, St. Paul, Minnesota, May 14, 2012. http://www.ce.utwente.nl/car/ICRA2012/workshop.html[4] C. J. Berthelette, G. S. Iannacchione, S. Koehler, and M. B. Popovic, "The One-To-Many Concept and Soft Robotics ExoMusculature" (unpublished, March10,2012) available online at http://users.wpi.edu/~mpopovic/media/pubs/TheOne-To-ManyExoMusculatureMBP.pdf[5] T. R. Hunt, C. J. Berthelette, and M. B. Popovic (2013), “Linear One-to-Many (OTM) system: Many degrees of freedom independently actuated by one electric motor”, 5th Annual IEEE International Conference on Technologies for Practical Robot Applications (TePRA), Greater Boston Area, Massachusetts, USA, April 22-23, 2013, http://users.wpi.edu/~mpopovic/pages/TePRAfinalsubmission(finished)1YES.pdf .[6] Christopher Berthelette, Matthew DiPinto, Thane Hunt, and Marko Popovic (2013), “The General One-to-Many Concept”, submitted to Actuators (ISSN 2076-0825) international open access journal.[7] Liu, Yang, Shiqi Li, and Ming Xie. "Design and implementation of a new single-motor driven arm manipulator." Mechatronics and Automation, 2007. ICMA 2007. International Conference on. IEEE, 2007.[8] Li, Shiqi, Yang Liu, and Ming Xie. "Implementation of a single motor driven manipulator with multiple joints." Industrial Robot: An International Journal 38.1 (2011): 48-57.[9] Cheng, Nadia, et al. "Design and analysis of a soft mobile robot composed of multiple thermally activated joints driven by a single actuator." Robotics and Automation (ICRA), 2010 IEEE International Conference on. IEEE, 2010 [10] S. B. Kesner, L. Jentoft, F. L. Hammond, R. D. Howe and M. B. Popovic (2011). "Design Considerations for an Active Soft Orthotic System for Shoulder Rehabilitation" 33rd Annual International IEEE EMBS Conference , August 30 - September 02, 2011, Boston, USA. [11] Blumenau, A., Girardo, D., O., Lin, E., L., Mandala, S., and Popovic, M. B, "Physics applied to post-stroke rehabilitation", AIP SPS award June 2011 interim report. (available online at www.spsnational.org/programs/awards/2011/ugr2011_Worcester.pdf)[12] Girardo, D. O., and Popovic, M. B, (2011) "Physics applied to poststroke rehabilitation; Shoulder Soft Robotics Brace", AIP SPS award December 2011 final report. (available online at: http://www.spsnational.org/programs/awards/2011/ugr11_WPI.pdf ) [13] Ignacio Galiana, Frank L. Hammond III, Robert D. Howe, and Marko B. Popovic, “Wearable Soft-Orthotic Device for Post-Stroke Shoulder Rehabilitation: Identifying Misalignments” International Conference on Intelligent Robots and Systems, IROS 2012, October 7-12, 2012. Vilamoura, Algarve, Portugal. (demo available at http://walltrust.com/ALL/SoftRoboticsSuitWeightLifting.AVI[14] Y.-L. Park, B. Chen, D. Young, L. Stirling, R. J. Wood, E. Goldfield, and R. Nagpal, "Bio-Inspired Active Soft Orthotic Device for Ankle Foot Pathologies," Proc. IEEE/RSJ Int. Conf. Intell. Rob. Syst. (IROS'11), San Francisco, CA, September, 2011, pp. 4488-4495.

Page 11: cga/mp/GeneralOTMforproposalwithCMU.docx · Web viewHowever, this traditional approach limits natural DoF and reduces comfort for the user. Further, misalignments between biological

[15] M. Wehner, Y.-L. Park, C. J. Walsh, R. Nagpal, R. J. Wood, T. Moor, and E. Goldfield, "Experimental Characterization of Components for Active Soft Orthotics," Proc. IEEE Int. Conf. Biomed. Rob. Biomechatro. (BioRob'12), Roma, Italy, June, 2012, pp. 1586-1592.[16] E. C. Goldfield, Y.-L. Park, B. Chen, W.-H. Hsu, A. Wessendorf, D. Young, M. Wehner, D. Stephen, L. Stirling, D. Newman, R. Nagpal, E. Saltzman, K. G. Holt, C. Walsh, and R. J. Wood, "Bio-Inspired Design of Soft Robotic Assistive Devices: The Interface of Physics, Biology, and Behavior," Ecological Psychology, Vol. 24, No. 4, pp. 300-327, 2012. [17] Y.-L. Park, B. Chen, C. Majidi, R. J. Wood, R. Nagpal, and E. Goldfield, "Active Modular Elastomer Sleeve for Soft Wearable Assistance Robots," Proc. IEEE/RSJ Int. Conf. Intell. Rob. Syst. (IROS'12), Vilamoura, Portugal, October, 2012, pp. 1595-1602.[18] Y.-L. Park, J. Santos, E. C. Goldfield, and R. J. Wood, “A Soft Wearable Robotic Device for Active Knee Motions through Development of Compact Flat Pneumatic Artificial Muscles,” Submitted to IEEE Int. Conf. Rob. Autom. (ICRA’14), Hong Kong, China, 2014.[19] S. K. Agrawal, et al., “Optimization and Design of a Cable Driven Upper Arm Exoskeleton”, in proceedings of Int. Design Eng. Tech Conf. (IDETC/CIE), 2009.[20] E. A. Brackbill, Y. Mao, S. K. Agrawal, et al., “Dynamics and Control of a 4-dof Wearable Cable-driven Upper Arm Exoskeleton”, in proceedings of Int. Conf on Robotics and Automation”, 2009.[21] Dollar, A and Herr. H. “Lower Extremity Exoskeletons and Active Orthoses:Challenges and State-of-the-Art” IEEE Transactions on Robotics (2008) Volume: 24, Issue: 1, Pages: 144-158[22] Gopura, R.A.R.C.; Kiguchi, K.;and Bandara, D.S.V., “A brief review on upper extremity robotic exoskeleton systems”, 6th IEEE International Conference on Industrial and Information Systems (ICIIS), 2011.[23] H. I. Krebs, N. Hogan, et al., “Overview of clinical trials with MIT-MANUS: a robot-aided neuro-rehabilitation facility”, Technology Health Care. vol. 7, 1999, pp. 419-23.[24] L. E. Kahn, et al., “Robot-assisted reaching exercise promotes arm movement recovery in chronic hemiparetic stroke: a randomized controlled pilot study”, J Neuroengineering Rehabil., vol. 3, 2006. [25] M. B. Popovic, “Biomechanics and Robotics”, 364 pages, (in press), Copyright © 2014 Pan Stanford Publishing Pte. Ltd., Singapore, ISBN 978-981-4411-37-0 (Hardcover), 978-981-4411-38-7 (eBook), www.panstanford.com[26] I. Hunter & S. Lafontaine, “A comparison of muscle with artificial actuators”, Technical Digest IEEE Solid State Sensors & Actuators Workshop, 1992, pp. 178-185.[27] R. Full and K. Meijer “Metrics of natural muscle.” In Electro Active Polymers (EAP) as Artificial Muscles, Reality Potential and Challenges, ed. Y. Bar-Cohen, 67-83. SPIE Press 2001.[28] John D. Madden, Nathan Vandesteeg, Patrick A. Anquetil, Peter G. Madden, Arash Takshi, Rachel Z. Pytel, Serge R. Lafontaine, Paul A. Wieringa and Ian W. Hunter, “Artificial Muscle Technology: Physical Principles and Naval Prospects”, IEEE Journal of Oceanic Engineering, Vol. 29, No. 3, p. 706, July 2004.[29] Goldspink, G. (1985). Malleability of the motor system: A comparative approach. Journal of Experimental Biology, 115, 375-391.[30] Guyton, A.C. (1991). Medical Physiology. 8th ed. Philadelphia: W.B. Saunders.[31] Pratt, G.A.; Williamson, M.M., “Series elastic actuators,” IEEE/RSJ International Conference on Intelligent Robots and Systems 95. 'Human Robot Interaction and Cooperative Robots', Proceedings. 1995.

Page 12: cga/mp/GeneralOTMforproposalwithCMU.docx · Web viewHowever, this traditional approach limits natural DoF and reduces comfort for the user. Further, misalignments between biological

[32] Mori, Mayuko, Koichi Suzumori, Masayuki Takahashi, and Takashi Hosoya. "Very high force hydraulic McKibben artificial muscle with a p-phenylene-2, 6-benzobisoxazole cord sleeve." Advanced Robotics 24, no. 1-2 (2010): 233-254.[33] Richard M. Greenwald, Robert C. Dean, and Wayne J. Board. “Volume Management: Smart Variable Geometry Socket (SVGS) Technology for Lower-Limb Prostheses” JPO Journal of Prosthetics and Orthotics Vol 15, N 3, 2003, page 107-112.[34] Lia, Raymond A. "Borescope or endoscope with fluid dynamic muscle." U.S. Patent No. 4,794,912. 3 Jan. 1989.[35] Krauter, Allan I. "Hydraulic muscle pump." U.S. Patent No. 4,962,751. 16 Oct. 1990.[36] Ragner, Gary Dean, and Robert Daniel deRochemont Jr. "Pressure-actuated linearly retractable and extendible hose." U.S. Patent 6,948,527, issued September 27, 2005.[37] Ragner, Gary Dean. "Flexible hydraulic muscle." U.S. Patent 7,617,762, issued November 17, 2009.[38] Berardi, Michael, “Expandable garden hose”, US patent office publication number US 20130087205 A1, Application number US 13/690,670, Filing date Nov. 30, 2012.[39] D'alessio, Lawrence M. "Multi-channel laminar-flow fluid valve." U.S. Patent 4,448,214, issued May 15, 1984.[40] Schechter, Michael M. "Rotary hydraulic valve control of an electrohydraulic camless valvetrain." U.S. Patent 5,456,221, issued October 10, 1995.[41] Inou, N., H. Kobayashi, and M. Koseki. "Development of Pneumatic Cellular Robots Forming a Mechanical Structure." Seventh International Conference on Control, Automation, Robotics And Vision (ICARCV’02), Dec 2002, Singapore, 63-68.