CESNET a.l.e. Czech Educational and Scientific Network www.cesnet.cz
Long distance fiber connections in NREN, TF-NGN 1October 18, 2002
Long distance fiber connections in NREN
Lada Altmanová, Jan Radil,
Stanislav Šíma
CESNET a.l.e. Czech Educational and Scientific Network www.cesnet.cz
Long distance fiber connections in NREN, TF-NGN 2October 18, 2002
Customer Owned Fiber networks• Networks using optical fibres constructed, bought
or leased by some network users/customers• Wide independence of Customer Owned Fiber
(COF) networks on carriers• Unique window in time for fiber assets or IRU• Getting fiber means controlling the network• Path to deployment of different wavelengths for
different networks, lambda services, QoS on backbone, optical switching etc., when it makes sense
• COF networks are emerging chronologically from bottom of hierarchy to top
CESNET a.l.e. Czech Educational and Scientific Network www.cesnet.cz
Long distance fiber connections in NREN, TF-NGN 3October 18, 2002
Connections for WAN RENs• Interconnection of REN segments by carier’s
lambda services (e.g.: Starlight, CESNET, Pioneer, etc.)
• Interconnection of regional area REN’s lambda services (Ca*net4)
• Long distance owned or leased fibre, e.g.:– fibre owned or leased by a group of universities, etc.
(UCAID, CENIC, SWITCH, CESNET, etc.)
– fibre owned or leased by a group of RENs, etc. (CANARIE?, GEANT/DANTE?, Nordunet?, etc.)
CESNET a.l.e. Czech Educational and Scientific Network www.cesnet.cz
Long distance fiber connections in NREN, TF-NGN 4October 18, 2002
RENs using own or leased fibers• Advantages given by Customer Owned
Fiber (COF) networks are important for RENs
• Developing COF networks:– ORAN, I-wire, CalREN, SWITCH, CESNET,
SANET, Pioneer, ….
• Prepared COF network:– National LightRail, USA (2003) ….– European fiber connections?
CESNET a.l.e. Czech Educational and Scientific Network www.cesnet.cz
Long distance fiber connections in NREN, TF-NGN 5October 18, 2002
Equipment and servicesfor COF RENs
• Significant investments in LH/ULH optronics and ongoing maintenance are required
• Fiber leasing or maitenance of own fibers instead of carier services?
• Optronics vendors now are becoming aware (at least in USA) of the non-carrier (enterprise, RENs) market for their WAN gear
CESNET a.l.e. Czech Educational and Scientific Network www.cesnet.cz
Long distance fiber connections in NREN, TF-NGN 6October 18, 2002
PoP to PoP fiber lengthsin COF REN
• Metropolitan lines < cca 80 km (e.g. COF RENs in Praha or Brno, etc.)
• Long hall (LH) lines: cca 80-400 km (e.g. PEI, SWITCH, CESNET, etc.)
• Ultra long hall (ULH) lines > cca 400 km (e.g.: US National LightRail?)
• Air distances are 50 – 90% of this due to terrain profiles and fibre curves
CESNET a.l.e. Czech Educational and Scientific Network www.cesnet.cz
Long distance fiber connections in NREN, TF-NGN 7October 18, 2002
Type of lines depending on in-line equipment
(equipment placed away of PoPs)• Type 0: None (NIL)• Type 1: Dispersion compensators (DCIL)• Type 2: Optical amplifiers (OAIL)• Type 3: Regenerators (RIL)(Possibilities depends on distance, fibre type,
basic speed, color count, etc.)
CESNET a.l.e. Czech Educational and Scientific Network www.cesnet.cz
Long distance fiber connections in NREN, TF-NGN 8October 18, 2002
Ostrava – Olomouc (Long distance GE line since January 7, 2002)• 149 km leased fiber, in-line L2 switch used as
regenerator• Traffic statistics:
http://www.cesnet.cz/provoz/zatizeni/• Line cards: GE for GSR with GBIC-ZX• Catalyst 3512 XL with GBIC-ZX• GBIC-ZX: Pin: 0 to 4,77dBm, Pout: -23 to 0dBm,
power budget: 23dB
CESNET a.l.e. Czech Educational and Scientific Network www.cesnet.cz
Long distance fiber connections in NREN, TF-NGN 9October 18, 2002
Praha-Pardubice(Long distance GE line since May 17, 2002)
• 189 km leased fibre G.652, attenuation 44.65dB, without in-line equipment
• Traffic statistics: http://www.cesnet.cz/provoz/zatizeni/
• Line cards: GE for GSR with GBIC-ZX• Optical amplifier: Keopsys KPS-BT-C-21-Bo-FA
21dBm booster, C-band single channel• Optical attenuator: 5dB (for optical amplifier
input)
CESNET a.l.e. Czech Educational and Scientific Network www.cesnet.cz
Long distance fiber connections in NREN, TF-NGN 10October 18, 2002
Keopsys Optical Amplifiers connection
CESNET a.l.e. Czech Educational and Scientific Network www.cesnet.cz
Long distance fiber connections in NREN, TF-NGN 11October 18, 2002
Recomended line end aplication for 1 Gb/s and 2.5 Gb/s lines (NIL)
• Booster only - up to 180km
• Booster with preamp - up to 220km
• Booster with preamp and Raman - up to 270km
CESNET a.l.e. Czech Educational and Scientific Network www.cesnet.cz
Long distance fiber connections in NREN, TF-NGN 12October 18, 2002
Prepared long distance single fiber Fast Ethernet lines (NIL)
• Two colors in one fiber, one color for one direction (bi-directional transfer)
• Fiber length up to 125 km (G.652)• Price of single fibre leasing: 51-64% of pair price
(depends on provider)• Price is comparable with carrier’s 34 Mb/s SDH service
(but this use microwave transfer, at least in part)
CESNET a.l.e. Czech Educational and Scientific Network www.cesnet.cz
Long distance fiber connections in NREN, TF-NGN 13October 18, 2002
Single fibre bi-directional Fast Ethernet transferFibre length (km)
Leased fibre(EURO/m/ month)
EURO/month
Pair ofconvertors (EURO)
Leased pair offibres (EURO/m/month)
Leased pair offibers (EURO/month)
Convertors payoff (month)
10 0,03 267 5 552 0,04 417 37,020 0,02 467 5 552 0,04 833 15,130 0,02 700 5 552 0,04 1 250 10,140 0,02 933 7 773 0,04 1 667 10,650 0,02 1 167 7 773 0,04 2 083 8,560 0,02 1 400 14 133 0,04 2 500 12,870 0,02 1 633 14 133 0,04 2 917 11,080 0,02 1 867 14 133 0,04 3 333 9,690 0,02 2 100 14 133 0,04 3 750 8,6100 0,02 2 333 14 133 0,04 4 167 7,7110 0,02 2 310 15 301 0,04 4 583 6,7125 0,02 2 625 15 301 0,04 5 208 5,9
4,4 0,20 880 5 257 0,33 1 467 9,0
100BaseTx, SM,1550nm,1-30km,RJ45-SC/PC100BaseTx, SM,1550nm,20-50km,RJ45-SC/PC100BaseTx, SM,1560nm,40-100km,RJ45-SC/PC100BaseTx,SM,1520&1560nm,125km,RJ-SC
Example for different price level:
Type of convertors (Nbase-Xyplex):
EM316WFC/S5&EM316WFT/S5
EM 316WFC/S2 & EM316WFT/S2EM 316WFC/S3 &EM 316WFT/S3EM 316WFC/S4 &EM 316WFT/S4
CESNET a.l.e. Czech Educational and Scientific Network www.cesnet.cz
Long distance fiber connections in NREN, TF-NGN 14October 18, 2002
StarLight-NetherLight and further
• Extension of international experimental lambda switching network to Praha expected from January 2003 (lambda 2.5 Gb/s Amsterdam - Praha), upgrade to 10 Gb/s from July 2003 (lamda or leased fiber)
• Further extensions?
CESNET a.l.e. Czech Educational and Scientific Network www.cesnet.cz
Long distance fiber connections in NREN, TF-NGN 15October 18, 2002
CAnet4
CERN15454
2.5Gb (OC-192)
2.5Gb2.5Gb
OC-48GE
Chi/Ams15454
Chi/CA15454
10Gb Oct 2002
MEMS
10Gb Jan 2003
Prague15454
London
NY Abilene?
Border Router
Ams15454
Border Router
1670
Alcatel1670
StarLight
10GE
T640
Groningen
Stockholm
(US clusters)6509
CESNET a.l.e. Czech Educational and Scientific Network www.cesnet.cz
Long distance fiber connections in NREN, TF-NGN 16October 18, 2002
Long distance 10 GE fibre lines• Expected distance up to 300km on dispersion
shifted fiber (G.655), i.e. NIL (Nothing In-Line)• Expected distance up to 300km with in-line
chromatic dispersion compensation only on classic fiber (G.652), i.e. DCIL or NNIL (Near Nothing In-Line) type
• for G.652 compensation of chromatic dispersion by DCF (Dispersion Compensating Fiber) each 50-60 km
• Booster, preamp and Raman optical amplifiers on end points
CESNET a.l.e. Czech Educational and Scientific Network www.cesnet.cz
Long distance fiber connections in NREN, TF-NGN 17October 18, 2002
Prepared testing of 10 GE fibre lines
• Field fiber testbed with dispersion shifted fiber (G.655) and classic fiber (G.652) – from December 2002
• Combination of intercity G.655 and first mile G.652 fibers??
• Connection of interface cards an optical amplifiers: results depends on parameters of used optical devices (lasers in Cisco interface cards or other hardware)
CESNET a.l.e. Czech Educational and Scientific Network www.cesnet.cz
Long distance fiber connections in NREN, TF-NGN 18October 18, 2002
Availability of Cisco 10GE cards- long reach (40 km) version
• Catalyst 6500 1550nm: yes
• OSR 7600 1550nm: yes
• GSR 12400 1550nm: to be 2002
• ONS 15454: is prepared
• other producer: we are interested to negotiate testing
CESNET a.l.e. Czech Educational and Scientific Network www.cesnet.cz
Long distance fiber connections in NREN, TF-NGN 19October 18, 2002
Long distance fiber line registration service?
• We offer registration service for NIL and DCIL lines (for better experience exchange)– over 80 km for 1 Gb/s and 2.5 Gb/s on fiber
pair– over 40 km for 10 Gb/s and more on fiber pair– over 20 km for 100 Mb/s and more on single
fiber
CESNET a.l.e. Czech Educational and Scientific Network www.cesnet.cz
Long distance fiber connections in NREN, TF-NGN 20October 18, 2002
Acknowledgements
• Jan Gruntorad and colleagues from CESNET
• Serenate initial workshop speakers