CERTIFICATION TEST UPDATE TO GTR7 prepared by: Paul Depinet 4/23/2013
© 2013 Humanetics Innovative Solutions, Inc. This presentation is the proprietary property of Humanetics Innovative Solutions, Inc; a registered company in Plymouth, Michigan, USA. The report includes confidential information. Disclosure, use, copying, or distribution of this information without the written authorization of Humanetics Innovative Solutions is prohibited.
©2013 Humanetics Innovative Solutions Inc. – Confidential & Proprietary 2/20/2013
Agenda
• Current tests – data analysis o R&R of certification o Correlation to car seat sled tests
• New tests under development o Design o FE study o Manufacture equipment o Testing
• Timeline
©2013 Humanetics Innovative Solutions Inc. – Confidential & Proprietary 2/20/2013
Current Certification Test Trials
• Jacket Impact test • Pelvis impact tests
o Back, bottom • Spine quasi-static bending
o Flexion, extension, with & without damper & torsion pins
• Mini-sled • Mini-sled with head restraint
©2013 Humanetics Innovative Solutions Inc. – Confidential & Proprietary 2/20/2013
New Tests under development
• Bumper compression on spine • Full back support mini-sled • Quasi-static jacket compression • Quasi-static pelvis compression
©2013 Humanetics Innovative Solutions Inc. – Confidential & Proprietary 2/20/2013
Bumper Compression on Spine
©2013 Humanetics Innovative Solutions Inc. – Confidential & Proprietary 2/20/2013
Full Back Support mini-sled
©2013 Humanetics Innovative Solutions Inc. – Confidential & Proprietary 2/20/2013
FE Study on Full Back Support Test
• CAE group in Europe o Using latest Biorid model
• Several load cases o Vary bumper stiffnesses o Vary jacket stiffness o Vary head to restraint friction
• Varying test conditions and sled parameters • Conclusions so far
©2013 Humanetics Innovative Solutions Inc. – Confidential & Proprietary 2/20/2013
Vary bumper stiffness – Y-rotation_thorax and lumber spine
Base run Run+40% Run-40%
10002
79473 143499
10003
10004
©2013 Humanetics Innovative Solutions Inc. – Confidential & Proprietary 2/20/2013
Vary bumper stiffness – Y-rotation_thorax and lumber spine
@ 670 ms
No significant difference observed
∆ =1.9 Nm
Base run Run+40% Run-40%
1.53 Nm
©2013 Humanetics Innovative Solutions Inc. – Confidential & Proprietary 2/20/2013
Vary Head to restraint friction-
Results - Neck upper load cell
Friction_0.15 Friction_0.3 Friction_0.7
@ 660 ms
@ 660 ms
@ 660 ms
©2013 Humanetics Innovative Solutions Inc. – Confidential & Proprietary 2/20/2013
Conclusions so far
• Possibly detect bumper variations • Possibly detect jacket • Head to restraint friction is critical
o Is this a problem with car seat testing as well?
©2013 Humanetics Innovative Solutions Inc. – Confidential & Proprietary 2/20/2013
Timeline for Work
• Work plan was developed in March • Program management if
following/tracking/pushing • Currently on track for early August completion
certification work o Hopefully some conclusions in late May