14
1 Certification and Implementation of Airborne Arc Fault Circuit Breakers Presented by Stephen Slotte FAA Transport Standards Staff FAA 2nd Annual EAPAS Conference

Certification and Implementation of Airborne Arc Fault Circuit Breakers

  • Upload
    pearly

  • View
    35

  • Download
    0

Embed Size (px)

DESCRIPTION

FAA 2nd Annual EAPAS Conference. Certification and Implementation of Airborne Arc Fault Circuit Breakers. Presented by Stephen Slotte FAA Transport Standards Staff. Background. Aging Systems R,E & D FAA R,E,&D Intrusive Inspections Arc Fault Circuit Breaker Development - PowerPoint PPT Presentation

Citation preview

Page 1: Certification and  Implementation of  Airborne  Arc Fault Circuit Breakers

1

Certification and Implementation of Airborne

Arc Fault Circuit Breakers

Presented by

Stephen Slotte

FAA Transport Standards Staff

FAA 2nd Annual EAPAS Conference

Page 2: Certification and  Implementation of  Airborne  Arc Fault Circuit Breakers

2

Background

• Aging Systems R,E & D– FAA R,E,&D

• Intrusive Inspections

• Arc Fault Circuit Breaker Development

• Interconnect System Testing and Assessment

• Inspection and Testing Technology Development

Page 3: Certification and  Implementation of  Airborne  Arc Fault Circuit Breakers

3

Background:Arc Faults

• Present aircraft circuit breakers are designed to protect against overloads and short circuits.

• Arcing faults draw less current than hard faults and are intermittent in duration.

• Arcing faults can cause systems failures and fires.

Page 4: Certification and  Implementation of  Airborne  Arc Fault Circuit Breakers

4

Background:Wire Degradation

• Wiring insulation degradation increases with time due to a variety of reasons such as:– Chaffing– Environmental

stresses– Maintenance.

Results of a Fleetwide Fuel Boost Pump Wire Inspection

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

5

0-20K 20-30K 30-40K 40-50K 50-60K 60-70K 70K+Fleet

Flight hours/aircraft

Occ

ura

nce

s/m

illi

on

fl

igh

t h

ou

rs

Bare Wire >50% Insulation Gone

• Degradation varies due to design, maintenance, and operational differences

Page 5: Certification and  Implementation of  Airborne  Arc Fault Circuit Breakers

5

BAGGAGE BINS

ABOVE ROW 6 & 7

During flight the crew had

to cut into this ceiling area

to put fire out.

Page 6: Certification and  Implementation of  Airborne  Arc Fault Circuit Breakers

6

Page 7: Certification and  Implementation of  Airborne  Arc Fault Circuit Breakers

7

Background:Current Inspection Technology

• Current inspection and surveillance methods for aircraft wiring are limited in effectiveness and periodic in frequency.

• Arc Fault Circuit Breakers provide continuous protection.

Page 8: Certification and  Implementation of  Airborne  Arc Fault Circuit Breakers

8

FAA Approach

• Develop certification criteria compatible and in parallel with SAE activity– TSO, based on SAE developed AFCB

Specification– Installation Advisory Circular

• Be ready to issue TSO and AC at the completion of initial SAE activity scheduled for January, 2003

Page 9: Certification and  Implementation of  Airborne  Arc Fault Circuit Breakers

9

Realities of New Technologies

• The FAA is committed to expedite airborne AFCB technology. However...– Learning curve associated with certification of

new technology– Expect initial projects to be scrutinized more

than a standard STC

• Initial AFCB projects by Issue Paper process

Page 10: Certification and  Implementation of  Airborne  Arc Fault Circuit Breakers

10

Major Installation Issues

• Common Causes of Nuisance Trips– Load Characteristics– Crosstalk (e.g.EMI, Lightning, adjacent wiring)– Feedback (parallel circuits)

• Fault Masking– Algorithm Dependent

• Post Trip Maintenance– May need NDT in addition to visual

Page 11: Certification and  Implementation of  Airborne  Arc Fault Circuit Breakers

11

Current Status

• Current FAA certification of AFCBs for non-essential circuits

• SAE AFCB specification nearing completion

• TSO and AC in development

• Issue Papers– Project Specific– Document means of compliance until TSO and AC

published

Page 12: Certification and  Implementation of  Airborne  Arc Fault Circuit Breakers

12

AFCB Issue Paper

• Underlying Certification Philosophy– Provide a path for manufacturers to install AFCBs on

a non-interference basis for purposes of gathering data

– Limit AFCB installation to non-essential systems until adequate service history data can demonstrate proper function and reliability

– Limit AFCB installation on critical circuits such that continued safe flight and landing can be achieved given an assumed common-mode nuisance trip

Page 13: Certification and  Implementation of  Airborne  Arc Fault Circuit Breakers

13

AFCBs- Summary

• Potential benefits– Protection against internal wire bundle arc fault

damage• Minimize wiring related smoke and fire incidents

• Minimize common mode wire bundle failures

• Possible risks– Nuisance trips– Post trip diagnosis issues

Page 14: Certification and  Implementation of  Airborne  Arc Fault Circuit Breakers

14

Point of Contact

• Brett Portwood– Los Angeles ACO– 3960 Paramount Boulevard

ANM-130LLakewood, CA 90712

– 562.627.5350– [email protected]