Upload
dinhdat
View
218
Download
4
Embed Size (px)
Citation preview
Certificate of Qualification mn Welding & Inspection L.L. C.
Certifies that
Tim Clarke Has successfully completed
Welder Performance Qualification testing under
ASME Section IX IUCF GTA WP8
July 30, 2010 Indefinite As Per Code Date of Qualification Date of Expiration IU Cyclotron Bennie D. Flynn CWI # 00090731 Company AWS Certified Welding Inspector
«%&•:// \\'--yy!k!\ fom&^Ji/ sv'x^yy m§i^-J// \v=
IU Cyclotron Page10f2
Welder Performance Qualifications Record IUCF P8 TC
WQTR No. IUCF P8 TC Name Tim Clarke Welder Id TC Clock no. TC
WPS No. IUCF GTAW P8 Revision 0 Date 7/28/2010 Stamp no. TC_
Welding process(es) used GTAW Type Manual (Xl Machine • Semi-Auto • Auto •
Variables (QW-350) Record Actual Values
Base material welded 304
ASME P-No. 8 to P-No. 8
Thickness: .065 in
Diameter(Pipe): 1J5 in
Notes
Backing (QW-402) no_
Consumable Insert (GTAW/PAW) Use Insert •
Filler metals (QW-404)
SFA spec. 5JJ
AWS Class. ER316
F-No. 6
Weld deposit thickness .065
Position (QW-405) 1G
Progression: Up • Down •
Backing gas: Argon
Current/Polarity AC • DCEP • DCEN Kl Pulsed K
Transfer Mode (GMAW):short-Cir. • Globular D Spray D
Other
Qualification Range
P#1 -P#11
.0625 - .130 in
1 - Unlimited in
With Insert • Without Insert P
5.9 ERXXX F#6
up to .130"
1G1F, 2F
Up • Down •
Argon
AC • DCEP • DCEN Kl Pulsed
Short-Cir. • Globular D Spray •
Guided Bend Test Results
Guided Bend Tests Type p Side Result (QW-462.2) Kl Trans. R & F type (QW-462.3a) P Long. R & F Result (QW-462.3b)
Type Result Type Result
Acceptable QW-163
Acceptable QW-163
Acceptable QW-163
Acceptable QW-163
Bennie D Flynn CWI 000907J31 QCI EXP. 9/ /2012
Radiographic Test Results (QW-304 and QW-305)
Film Identification No.
Visual Inspection Acceptable Yes Fillet weld-fracture test / Defects length and percent in.
Macro test fusion ; Fillet leg size in. x in. Concavity/convexity in.
Welding test conducted by Flynn Welding Inspection LLC Laboratory test no. IUCF TC
Mechanical tests conducted by Flynn Welding Inspection Test date 7/30/2010
We certity that the statements in this record are correct and that the test coupons were prepared, welded, and tested in accordance
with the requirements of Section IX of the ASME Code.
Manufacturer IU Cyclotron Code Year 2007
By Walt Fox Date 7/30/2010
IU Cyclotron Page2of2
Weld Log IUCFPSTC
Test Configuration This WQTR was qualified on 7/30/2010 and will expire after an inactivity period of 180 days.
This record will be flagged for renewal at least 30 days before it is due to expire.
GTAW Current Status:Expires in 175 days on 1/24/2011
Current Status:Unknown
Process WQTR Weld Date Note
GTAW 7/28/2010 Tim Clarke welded GTAW
9405 N. Newark Rd. AWS Certified J&fii i, Solsberry, IN 47459 Inspector & Educator « * & % Cell: (812) 327-7437
FLYNN WELDING & INSPECTION L.L.C. July 30, 2010
To: IU Cyclotron
WPS#: IUCF GTAW P#8
Welder: Tim Clarke
Pipe 1 1/2" Specimen
#
#1
#2
#3
#4
.065 1G SA213 Type of bend Face
Root
Face
Root
Figure
QW 463.2(d)
QW 463.2(d)
QW 463.2(d)
QW 463.2(d)
Remarks
Acceptable QW-163
Acceptable QW-163
Acceptable QW-163
Acceptable QW-163
Tests were performed on Watts W-50 .
The specimens were tested and inspected in accordance with ASME Section IX (2007).
peetfi Bennie D Flynn
nie LXFlynh^y \ M ^ cwi 00090731 AWS CWI #00090731 ^r QCI EXP. 9/1/2012 Flynn Welding & Inspection LLC