12
CERTIFICATE OF APPROPRIATENESS APPLICATION FORM Planner: ________________________________________________ Application received: ___ / ___ / ___ Application complete: ___ / ___ / ___ Rev. 01.2017 PROPERTY Address Historic District / Landmark HCAD # Subdivision Lot Block DESIGNATION TYPE PROPOSED ACTION Landmark Contributing Alteration or Addition Relocation Protected Landmark Noncontributing Restoration Demolition Archaeological Site Vacant New Construction Excavation DOCUMENTS Application checklist for each proposed action and all applicable documentation listed within are attached OWNER APPLICANT (if other than owner) Name Name Company Company Mailing Address Mailing Address Phone Phone Em Email Signature Signature Date Date ACKNOWLEDGEMENT OF RESPONSIBILITY Requirements: A complete application includes all applicable information requested on checklists to provide a complete and accurate description of existing and proposed conditions. Preliminary review meeting or site visit with staff may be necessary to process the application. Owner contact information and signature is required. Late or incomplete applications will not be considered. Deed Restrictions: You have verified that the work does not violate applicable deed restrictions. Public Records: If attached materials are protected by copyright law, you grant the City of Houston, its officers, agencies, departments, and employees, non-exclusive rights to reproduce, distribute and publish copyrighted materials before the Houston Archaeological and Historical Commission, the Planning Commission, City Council, and other City of Houston commissions, agencies, and departments, on a City of Houston website, or other public forum for the purposes of application for a Certificate of Appropriateness or building permit, and other educational and not for profit purposes. You hereby represent that you possess the requisite permission or rights being conveyed here to the City. Compliance: If granted, you agree to comply with all conditions of the COA. Revisions to approved work require staff review and may require a new application and HAHC approval. Failure to comply with the COA may result in project delays, fines or other penalties.

CERTIFICATE OF APPROPRIATENESS - Houston · remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CERTIFICATE OF APPROPRIATENESS - Houston · remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding

CERTIFICATE OF APPROPRIATENESS

APPLICATION FORM

Planner: ________________________________________________ Application received: ___ / ___ / ___ Application complete: ___ / ___ / ___

Rev. 01.2017

PROPERTY

Address

Historic District / Landmark HCAD #

Subdivision Lot Block

DESIGNATION TYPE PROPOSED ACTION

Landmark Contributing Alteration or Addition Relocation

Protected Landmark Noncontributing Restoration Demolition

Archaeological Site Vacant New Construction Excavation

DOCUMENTS

Application checklist for each proposed action and all applicable documentation listed within are attached

OWNER APPLICANT (if other than owner)

Name Name

Company Company

Mailing Address

Mailing Address

Phone Phone

Em Email

Signature Signature

Date Date

ACKNOWLEDGEMENT OF RESPONSIBILITY

Requirements: A complete application includes all applicable information requested on checklists to provide a complete and accurate description of existing and proposed conditions. Preliminary review meeting or site visit with staff may be necessary to process the application. Owner contact information and signature is required. Late or incomplete applications will not be considered.

Deed Restrictions: You have verified that the work does not violate applicable deed restrictions.

Public Records: If attached materials are protected by copyright law, you grant the City of Houston, its officers, agencies, departments, and employees, non-exclusive rights to reproduce, distribute and publish copyrighted materials before the Houston Archaeological and Historical Commission, the Planning Commission, City Council, and other City of Houston commissions, agencies, and departments, on a City of Houston website, or other public forum for the purposes of application for a Certificate of Appropriateness or building permit, and other educational and not for profit purposes. You hereby represent that you possess the requisite permission or rights being conveyed here to the City.

Compliance: If granted, you agree to comply with all conditions of the COA. Revisions to approved work require staff review and may require a new application and HAHC approval. Failure to comply with the COA may result in project delays, fines or other penalties.

pianjc
Typewritten Text
510 Byrne St.
pianjc
Typewritten Text
Woodland Heights
pianjc
Typewritten Text
NA
pianjc
Typewritten Text
3
pianjc
Typewritten Text
24
pianjc
Typewritten Text
0372890000003
pianjc
Typewritten Text
x
pianjc
Typewritten Text
x
pianjc
Typewritten Text
x
pianjc
Typewritten Text
Brian and Jayne Piana
pianjc
Typewritten Text
510 Byrne St.
pianjc
Typewritten Text
Houston, TX 77009
pianjc
Typewritten Text
832-868-3379
Page 2: CERTIFICATE OF APPROPRIATENESS - Houston · remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding

CERTIFICATE OF APPROPRIATENESS

APPLICATION INSTRUCTIONS

Rev. 01.2017

Well in advance of the COA application deadline contact staff to discuss your project, application requirements, and, if necessary, to make an appointment to meet with staff for a project consultation. Visit the Historic Preservation Web Manual for historic district profiles, project guidance and forms. www.houstontx.gov/HistoricPreservationManual

Historic Preservation Office 832.393.6556 [email protected]

SUBMISSION INSTRUCTIONS

To submit application to Planning Department:

email documents to [email protected] (attachments must be less than 10MB)

send a Dropbox shared folder invitation to [email protected], or

contact staff to set up an appointment to drop off a disc or flash drive.

MEETING SCHEDULE

Applications are due 22 calendar days in advance of the HAHC meeting by 12 PM (noon) on the deadline date. Exception: revisions to items deferred or denied at the previous HAHC meeting are due 15 days in advance of the scheduled meeting.

Application deadlines are firm. All materials must be submitted by the deadline to be considered at the following HAHC meeting. Designs must be final at time of application; revisions will not be accepted after the deadline.

HAHC will not accept new material or redesigns presented at the HAHC meeting. Deferral until the following month’s meeting may be necessary in such cases to allow for adequate review by staff and commissioners.

HAHC monthly meetings are held at 3:00 PM at City Hall Annex, 900 Bagby Street, City Council Chambers, Public Level.

2017 Meeting Dates (Thursdays unless noted otherwise)

COA Application Deadlines Demolition / Relocation Posted Sign Deadlines

January 26 January 4 January 16

February 23 February 1 February 13

March 23 March 1 March 13

April 20 March 29 April 10

May 18 April 26 May 8

June 15 May 24 June 5

July 26 (Wednesday) July 3 July 16

August 23 (Wednesday) August 1 August 13

September 21 August 30 September 11

October 19 September 27 October 9

November 16 October 25 November 6

December 13(Wednesday) November 21 December 3

Page 3: CERTIFICATE OF APPROPRIATENESS - Houston · remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding

CERTIFICATE OF APPROPRIATENESS

APPLICATION INSTRUCTIONS

Rev. 01.2017

DEFINITIONS

Addition: any expansion to an existing building, structure or object.

Alteration: any change to the exterior of a building or structure, including adding, moving, removing or replacing an exterior feature.

Demolition: an act or process that destroys in whole, or a majority of, any building, structure, object or site.

Excavation: to expose, uncover, or remove by digging, cutting or hollowing out.

Exterior Feature: an element of the architectural character and the general arrangement of the external portion of a building, structure or object, including building materials and parts of the exterior wall assembly such as walls studs, interior shiplap and the foundation

Mandatory Repair: a repair of a building or structure that is necessary to comply with Article IX, Ch. 10, Houston Code of Ordinances, as evidenced by an order of the hearing official or the building and standards commission or by a citation.

New Construction: the erection of a new building, structure, or object, on a lot, site, or other property.

Relocation: any change in the location of a building, structure, or object.

Restoration: accurately recovering the form and detail of a building, structure, object, or site and its setting as it appeared at a particular period of time by means of the removal of later work, or by the replacement of missing earlier work, or both.

Page 4: CERTIFICATE OF APPROPRIATENESS - Houston · remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding

CERTIFICATE OF APPROPRIATENESS ALTERATION & ADDITION CHECKLIST

Rev. 01.2016

Well in advance of the COA application deadline contact staff to discuss your project and, if necessary, to make an appointment to meet with staff for a project consultation.

Complete all applicable items and submit with the COA application form. Staff can assist you in determining what items are required for your scope of work. An incomplete application may cause delays in processing or may be deferred to the next agenda. Application materials must clearly represent current and proposed conditions. Refer to Houston Code of Ordinances, Ch. 33 VII, Sec. 33-241 for approval criteria for alteration, rehabilitation, restoration and additions.

PROPERTY ADDRESS:

BUILDING TYPE ALTERATION TYPE

single-family residence

multi-family residence

commercial building

mixed use building

institutional building

garage

carport

accessory structure

other

addition

foundation

wall siding or cladding

windows or doors

porch or balcony

roof

awning or canopy

commercial sign

ramp or lift

other

WRITTEN DESCRIPTION

property description, current conditions and any prior alterations or additions

proposed work; plans to change any exterior features, and/or addition description

current building material conditions and originality of any materials proposed to be repaired or replaced

proposed new materials description; attach specification sheets if necessary

PHOTOGRAPHS label photos with description and location

elevations of all sides

detail photos of exterior elements subject to proposed work

historical photos as evidence for restoration work

DRAWINGS scale like drawings the same; include all dimensions and drawing scale; label with cardinal directions

current site plan

proposed site plan

current floor plans

proposed floor plans

current window and door schedule

proposed window and door schedule

demolition plan

current roof plan

proposed roof plan

current elevations (all sides)

proposed elevations (all sides)

massing/perspective

pianjc
Typewritten Text
510 Byrne St.
pianjc
Typewritten Text
x
pianjc
Typewritten Text
x
pianjc
Typewritten Text
x
pianjc
Typewritten Text
x
pianjc
Typewritten Text
pianjc
Typewritten Text
x
pianjc
Typewritten Text
x
pianjc
Typewritten Text
x
pianjc
Typewritten Text
x
pianjc
Typewritten Text
x
pianjc
Typewritten Text
x
pianjc
Typewritten Text
x
pianjc
Typewritten Text
x
pianjc
Typewritten Text
x
pianjc
Typewritten Text
x
pianjc
Typewritten Text
x
pianjc
Typewritten Text
x
pianjc
Typewritten Text
x
pianjc
Typewritten Text
x
pianjc
Typewritten Text
x
pianjc
Typewritten Text
Page 5: CERTIFICATE OF APPROPRIATENESS - Houston · remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding

510 Byrne St.

Application for Alteration

Property Description:

Home is a bungalow with an addition added in the rear of the house in the 1990s. All changes proposed are only on the addition, not on the original structure.

Proposed Work:

1. Replace siding on contributing structure (addition) with composite siding.a. Specifications of proposed composite siding attached. New Hardi Fibered Cement

Siding (1x6” smooth with an 1 ½” overlap)b. Current siding on addition is wood, waterfall siding. Current siding is a triple panel

wood 1”x 8” siding2. Change location of certain windows on the addition.

a. Specifications of proposed windows attached. New addition windows are Jeld Wen W-2500 series Auralast pine.

b. Elevation drawings showing existing window placement on sides of home attached.c. Elevation drawings showing proposed new window placement on sides of home

attached.3. Add roof in rear of house (addition) to cover existing deck.

a. Elevation drawing showing existing rear elevation attached.b. Elevation drawing showing proposed rear elevation with roof attached.

Page 6: CERTIFICATE OF APPROPRIATENESS - Houston · remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding

510 Byrne Street

Photos of existing addition

Rear elevation

Page 7: CERTIFICATE OF APPROPRIATENESS - Houston · remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding

510 Byrne Street

Photos of existing addition

West elevation

Page 8: CERTIFICATE OF APPROPRIATENESS - Houston · remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding

510 Byrne Street

Photos of existing addition

East elevation

Page 9: CERTIFICATE OF APPROPRIATENESS - Houston · remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding

THESE DRAWINGS ARE THE PROPRIETARY WORK PRODUCT AND PROPERTY OF WILLIAM SHAW & ASSOCIATES, INC.,DEVELOPED FOR THE EXCLUSIVE USE OF WILLIAM SHAW & ASSOCIATES, INC..USE OF THESE DRAWINGS ANDCONCEPTS CONTAINED THEREIN WITHOUT THE WRITTEN PERMISSION OF WILLIAM SHAW & ASSOCIATES INC.IS PROHIBITED AND MAY SUBJECT YOU TO A CLAIM FOR DAMAGES UNDER CURRENT TEXAS LAW AND STATUES.

remove

ExistingExisting

remove

remove

WEST EXISTING ELEVATION

Remove Upper Deck

Wood T111 Triple Lap Siding

Wood T111 Triple Lap Siding

Wood T111 Triple Lap Siding

Remove windowand frame & sheathopening

Remove windowand re-frame fornew window

Addition

Addition

Add

ition

Add

ition

remove

ExistingExisting

remove

remove

replaceremove

replace

replacereplace ExistingExisting

replacereplace

replaceremove

replace

replacereplace ExistingExisting

replacereplace

ExistingExisting

12'-10"

EAST EXISTING ELEVATION

remove upper deck

Remove windowand frame & sheathopening

Existing T111 Triple Lap Siding

Existing T111 Triple Lap Siding

Existing T111 Triple Lap Siding

Addition

Addition

Add

ition

Add

ition

replaceremove

replace

replacereplace ExistingExisting

replacereplace

replaceremove

replace

replacereplace ExistingExisting

replacereplace

ExistingExisting

removeremovereplace removeremovereplace replaceremove

replace

replaceremove

replace

Remove windowsand frame & sheathopening

remove door unit,frame-sheath-sidingin opening

remove door unit,frame-sheath-sidingin opening

remove door unit,frame-sheath-sidingin opening

remove door unit,frame-sheath-sidingin opening

Existing T111 Triple Lap Siding

SOUTH EXISTING ELEVATION

Remove Upper Porch

removeremovereplace removeremovereplace replaceremove

replace

replaceremove

replace

4206

Law

St.

Hou

ston

, Tx

7700

571

3-66

6-19

31

F

ax 7

13-4

32-1

006

Bri

an &

Jay

ne P

iana

510

Byr

ne S

t.H

oust

on, T

exas

770

09

A

DescriptionDateNo.

Revisions

9-8-17 PRELIMINARY ESTIMATE

This Drawing and theinformation contained withinare proprietary to Wm. Shawand Associates and areprotected by law. They maynot be reproduced ordistributed without theexpress written consent ofWm. Shaw and Associates.

Drawing Title

Drawing No.

Approvals:

By: Date:

Homeowner

Framer

Plumber

Electrician

H.V.A.C.

Trim

W.M. Shaw

B

D/E3

Demo/Existing

Elevations

Page 10: CERTIFICATE OF APPROPRIATENESS - Houston · remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding

THESE DRAWINGS ARE THE PROPRIETARY WORK PRODUCT AND PROPERTY OF WILLIAM SHAW & ASSOCIATES, INC.,DEVELOPED FOR THE EXCLUSIVE USE OF WILLIAM SHAW & ASSOCIATES, INC..USE OF THESE DRAWINGS ANDCONCEPTS CONTAINED THEREIN WITHOUT THE WRITTEN PERMISSION OF WILLIAM SHAW & ASSOCIATES INC.IS PROHIBITED AND MAY SUBJECT YOU TO A CLAIM FOR DAMAGES UNDER CURRENT TEXAS LAW AND STATUES.

W05W05W05W05

W05W05W05W05

W05W05W05W05

W05W05W05W05

W03W03

W05W05

ExistingExisting

ExistingExisting

W03W03

W05W05

ExistingExisting

ExistingExisting

ExistingExisting

12'-2 3/4"13'

EAST ELEVATION

New Hardie Fibered Cement 1"x 6" Smoothwith an over lap of 1 1/2"

T111 Triple Lap Wood Siding

New Porch Roof

5/12 Pitch

Patch framing,sheathing, siding

frame for newwindow unit

Window relocated8" to south-changeheader and framing

N

Hardie Fibered Cement 1"x 4"Vertical divider between existingwood siding and new siding

Addition

Addition

Add

ition

Original Structure

Original Structure

Ori

gina

l Str

uctu

re

New Windows: Jeld Wen W-2500 Series Auralast Pine

W05W05W05W05

W05W05W05W05

W05W05W05W05

W05W05W05W05

W03W03

W05W05

ExistingExisting

ExistingExisting

W03W03

W05W05

ExistingExisting

ExistingExisting

ExistingExisting

ExistingExisting

W02W02

W01W01

W03W03

ExistingExisting

W04W04

W01W01

W03W03

ExistingExisting

W04W04

W01W01

W02W02

W01W01

WEST ELEVATION

New Porch Roof

5/12 Pitch

Frame for newwindow Frame for new

window

T111 Triple Lap Wood SidingNew Hardie Fibered Cement 1"x 6" Smoothwith an over lap of 1 1/2"

New Windows: Jeld Wen W-2500 Series Auralast Pine

Addition

Add

ition

Addition

Add

ition

Hardie Fibered Cement 1"x 4"Vertical divider between existingwood siding and new siding

Original Structure

Original Structure

Ori

gina

l Str

uctu

re

ExistingExisting

W02W02

W01W01

W03W03

ExistingExisting

W04W04

W01W01

W03W03

ExistingExisting

W04W04

W01W01

W02W02

W01W01 W04W04

D01D01

W04W04

D01D01

W06W06

D01D01

W06W06

D01D01

W04W04

W06W06W06W06

W04W04

W06W06W06W06

9'-4

1/2

"

14'

New Porch Roof

2x 10" Beam

Existing 6"x 6" Posts

5/12 Pitch

Ceiling: 1x6" T/G Pine

Patch framing, sheathingsiding where door & windowswere removed

Frame, sheathing,siding where doorunit was removed

NORTH ELEVATION

New Door Location

New Windows: Jeld Wen W-2500 Series Auralast Pine

Addition

Addition

Add

ition

Add

ition

New Hardie Fibered Cement 1"x 6" Smoothwith an over lap of 1 1/2"

W04W04

D01D01

W04W04

D01D01

W06W06

D01D01

W06W06

D01D01

W04W04

W06W06W06W06

W04W04

W06W06W06W06

ExteriorElevations

4206

Law

St.

Hou

ston

, Tx

7700

571

3-66

6-19

31

F

ax 7

13-4

32-1

006

Bri

an &

Jay

ne P

iana

510

Byr

ne S

t.H

oust

on, T

exas

770

09

A

DescriptionDateNo.

Revisions

9-8-17 PRELIMINARY ESTIMATE

This Drawing and theinformation contained withinare proprietary to Wm. Shawand Associates and areprotected by law. They maynot be reproduced ordistributed without theexpress written consent ofWm. Shaw and Associates.

Drawing Title

Drawing No.

Approvals:

By: Date:

A3

Homeowner

Framer

Plumber

Electrician

H.V.A.C.

Trim

W.M. Shaw

Scale: 1/4" = 1'

B

Page 11: CERTIFICATE OF APPROPRIATENESS - Houston · remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding

BRICK 4 INTERIOR 4 BRICK 4 BRICK 4(DEMO) (REMOVE BRICK)

WALL LEGEND

THESE DRAWINGS ARE THE PROPRIETARY WORK PRODUCT AND PROPERTY OF WILLIAM SHAW & ASSOCIATES, INC.,DEVELOPED FOR THE EXCLUSIVE USE OF WILLIAM SHAW & ASSOCIATES, INC..USE OF THESE DRAWINGS ANDCONCEPTS CONTAINED THEREIN WITHOUT THE WRITTEN PERMISSION OF WILLIAM SHAW & ASSOCIATES INC.IS PROHIBITED AND MAY SUBJECT YOU TO A CLAIM FOR DAMAGES UNDER CURRENT TEXAS LAW AND STATUES.

Exi

stin

gE

xist

ing

W06W06

W06W06

D01D01

W03W03

ExistingExisting

Exi

stin

gE

xist

ing

Exi

stin

g

Existing

Exi

stin

g

Exi

stin

g

2668

Exi

stin

g

5468

D06D06

D05D05

Existing D04D04

D05D05

D04D04

Exi

stin

g

W05W05 W05W05

W04W04

Existing ExistingExisting

ExistingU

P

UP

N

10'-3"

71'-6 15/16"

35'-10 7/16"

10'-5"

10'

13'-4

"

3'3' 4'-11"

7'-10 1/2"

4'-0 1/2"

8'-1"1'-10"

9'-3

"

9'-6"8'-2" 15'

14'-1"

3'-7

"13

'

13'13'-3 1/2"

14'2'-4"

13'-3

1/2

"

18'-1

1/2

"

15'

9'-7

"

9'-2

"

5'-7

"

3'-10"

2'-1

0 3/

16"

2'-1

0 1/

4"

2'

2'-3

"2'

-3"

3'-1

"

2'-1

"

7'

8'-4 3/8"

11'-6 15/16"

8"

16 SQ FT

1859 SQ FT

144 SQ FT

241 SQ FT

103 SQ FT178 SQ FT

187 SQ FT

199 SQ FT

444 SQ FT

50 SQ FT

70 SQ FT

25 SQ FT 276 SQ FT45 SQ FT

21 SQ FT

1 SQ FT

LIVING AREA

HALL

BEDROOM

LIVING

DINING

FAMILY

STUDY

HVAC SUPPLY

MASTER BATHMASTER BDRM

FIRST FLOOR PROPOSED PLANSCALE: 1/4 in = 1 ft

DECK

CLOSET

WOOD DECK

HVAC SupplyHVAC Supply

LAUNDRY

Living & Dining Room1. Re-install existing and new pine flooring

30X

54A

TT

ICA

CC

ES

S

CLOSET

NO WQRKNO WQRK

DOOR SCHEDULENUMBER LABEL QTY SIZE WIDTH HEIGHT DESCRIPTION THICKNESSD01 6068 1 6068 L/R EX 72 " 80 " FIBERGLASS 10 LITE FRENCH DOOR UNIT 1 3/4"D04 4068 2 4068 L/R IN 48 " 80 " 6-PANEL WOOD DOOR UNIT 1 3/8"D05 2668 2 2668 L IN 30 " 80 " 6-PANEL WOOD DOOR UNIT 1 3/8"D06 2868 1 2868 L IN 32 " 80 " 6-PANEL WOOD DOOR UNIT 1 3/8"

NO WQRK

BATH

WINDOW SCHEDULENUMBER LABEL QTY SIZE WIDTH HEIGHT DESCRIPTION COMMENTSW03 211310DH 1 211310DH 34 1/2 " 46 1/8 " NEW FIBERGLASS DH WINDOW 1/1 LITE-FULL TRIMW04 21139DH 1 21139DH 34 1/2 " 45 3/8 " NEW FIBERGLASS DH WINDOW 1/1 LITE-FULL TRIMW05 2650DH 2 2650DH 30 " 60 " NEW FIBERGLASS DH WINDOW 1/1 LITE-FULL TRIMW06 3850DH 2 3850DH 44 " 60 " NEW FIBERGLASS DH WINDOW 1/1 LITE-FUIL TRIM

AABB

CC DD

EE

FF

HH

GG

New Interior Wall

26'-6"

C.H. = 110 1/2"

C.H. = 110 1/2"

C.H. = 110 1/2"

C.H. = 111 1/2"

C.H. = 110 1/2"

C.H. = 111 1/2"

C.H. = 110 1/2"

return

All replaced windows comply with IRC 2012 code R312.2.1

First FloorProposed Plan

4206

Law

St.

Hou

ston

, Tx

7700

571

3-66

6-19

31

F

ax 7

13-4

32-1

006

Bri

an &

Jay

ne P

iana

510

Byr

ne S

t.H

oust

on, T

exas

770

09

A

DescriptionDateNo.

Revisions

9-8-17 PRELIMINARY ESTIMATE

This Drawing and theinformation contained withinare proprietary to Wm. Shawand Associates and areprotected by law. They maynot be reproduced ordistributed without theexpress written consent ofWm. Shaw and Associates.

Drawing Title

Drawing No.

Approvals:

By: Date:

A1

Homeowner

Framer

Plumber

Electrician

H.V.A.C.

Trim

W.M. Shaw

Scale: 1/4" = 1'

B

Page 12: CERTIFICATE OF APPROPRIATENESS - Houston · remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding in opening remove door unit, frame-sheath-siding

THESE DRAWINGS ARE THE PROPRIETARY WORK PRODUCT AND PROPERTY OF WILLIAM SHAW & ASSOCIATES, INC.,DEVELOPED FOR THE EXCLUSIVE USE OF WILLIAM SHAW & ASSOCIATES, INC..USE OF THESE DRAWINGS ANDCONCEPTS CONTAINED THEREIN WITHOUT THE WRITTEN PERMISSION OF WILLIAM SHAW & ASSOCIATES INC.IS PROHIBITED AND MAY SUBJECT YOU TO A CLAIM FOR DAMAGES UNDER CURRENT TEXAS LAW AND STATUES.

DN

W03W03 W05W05 W05W05

D01D01

W01W01W02W02W01W01

W04W04

W04W04

D02D02

D05D05

D03D03

D03D03

W06W06

D04D04

N

13'-0

1/2

"

3'-8

"

11'-1"

9'-4

"12'-6"

7'-1"

13'-0

1/2

"

7'-4

1/2

"

5'-1"

29'-3 1/2"

2'-1

"

4'-10"

11'-2

"

2'-7

"

3'-4

"

1'-6"

3'-8"

2'

6'-1"22'

11'-8"

1'-9

"

3'-8"

26'-1

0"

3'-9"

1'-4"

207 SQ FT

914 SQ FT

158 SQ FT

15 SQ FT

47 SQ FT180 SQ FT

60 SQ FT

4 S

Q F

T

3 S

Q F

T

20 SQ FT

LIVING AREA

BEDROOM

BEDROOM

PLAYROOM

BATH 2

BATH 1

HV

AC

30X54ATTICACCESS

CLOSET

CLOSET

WINDOW SCHEDULENUMBER LABEL QTY SIZE WIDTH HEIGHT EGRESS DESCRIPTION COMMENTSW01 31150DH 2 31150DH 47 " 60 " NEW FIBERGLASS DH WINDOW 1/1 LITE-FULL TRIMW02 4010FX 1 4010FX 48 " 12 " NEW FIBERGLASS FIXED GLASS WINDOW 1 LITE-FULL TRIMW03 1630DH 1 1630DH 18 " 36 " NEW FIBERGLASS DH WINDOW 1/1 LITE-FULL TRIMW04 31150DH 2 31150DH 47 " 60 " YES NEW FIBERGLASS DH WINDOW 1/1 LITE-FULL TRIMW05 31150DH 2 31150DH 47 " 60 " NEW FIBERGLASS DH WINDOWS 1/1 LITE-FULL TRIMW06 5020RS 1 5020RS 60 " 24 " NEW FIBERGLASS SLIDING WINDOW 1/1 LITE-FULL TRIM

DOOR SCHEDULENUMBER LABEL QTY SIZE WIDTH HEIGHT DESCRIPTION THICKNESSD01 2668 1 2668 R 30 " 80 " POCKET DOOR UNIT-6-PANEL SOLID MASONITE 1 3/8"D02 2668 1 2668 R IN 30 " 80 " 6-PANEL SOLID MASONITE DOOR UNIT 1 3/8"D03 2668 2 2668 L IN 30 " 80 " 6-PANEL SOLID MASONITE DOOR UNIT 1 3/8"D04 4068 1 4068 L/R IN 48 " 80 " 6-PANEL SOLID MASONITE DOUBLE DOOR UNIT 1 3/8"D05 5068 1 5068 L/R IN 60 " 80 " 6-PANEL SOLID MASONITE DOUBLE DOOR UNIT 1 3/8"

HV

AC

RE

TUR

N

II

JJ

New Interior Wall

C.H. = 111 3/4"

C.H. = 110 3/4"

C.H. = 110 3/4"

C.H. = 111 3/4"

C.H. = 95 1/2"

All replaced windows complywith IRC 2012 code R312.2.1

4206

Law

St.

Hou

ston

, Tx

7700

571

3-66

6-19

31

F

ax 7

13-4

32-1

006

Bri

an &

Jay

ne P

iana

510

Byr

ne S

t.H

oust

on, T

exas

770

09

A

DescriptionDateNo.

Revisions

9-8-17 PRELIMINARY ESTIMATE

This Drawing and theinformation contained withinare proprietary to Wm. Shawand Associates and areprotected by law. They maynot be reproduced ordistributed without theexpress written consent ofWm. Shaw and Associates.

Drawing Title

Drawing No.

Approvals:

By: Date:

Homeowner

Framer

Plumber

Electrician

H.V.A.C.

Trim

W.M. Shaw

A2

Second FloorProposed Plan

Scale: 1/2" = 1'

B