25
[email protected] CERN/CMS optical links radiation CERN/CMS optical links radiation damage damage K. Gill , J. Troska, F. Vasey R. Grabit, C. Sigaud M. Axer, S. Dris CERN EP-MIC/OE

CERN/CMS optical links radiation damage

  • Upload
    sophie

  • View
    45

  • Download
    0

Embed Size (px)

DESCRIPTION

CERN/CMS optical links radiation damage. K. Gill , J. Troska, F. Vasey R. Grabit, C. Sigaud M. Axer, S. Dris CERN EP-MIC/OE. Outline. Optical links QA programme Selection of test results. Optical link for CMS Tracker readout/control. 40k fibres (40Msamples/s analogue 8 bit) - PowerPoint PPT Presentation

Citation preview

Page 1: CERN/CMS optical links radiation damage

[email protected]

CERN/CMS optical links radiation CERN/CMS optical links radiation damagedamage

K. Gill, J. Troska, F. VaseyR. Grabit, C. SigaudM. Axer, S. Dris

CERN EP-MIC/OE

Page 2: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

OutlineOutline

• Optical links

• QA programme

• Selection of test results

Page 3: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

Optical link for CMS Tracker readout/controlOptical link for CMS Tracker readout/control

40k fibres (40Msamples/s analogue 8 bit)7k fibres (80Mbit/s digital)9k fibres (1Gbit/s digital)

Links ~70m long, multiple breakpoints

Page 4: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

Analogue link architecture (1996)Analogue link architecture (1996)

9612

CMS Tracker

Laser Transmitters on optohybridRuggedizedRibbon

Dense Multi-ribbonCable

Distributed PP In-line PP

Rx-Module

1

12

Back-end PP>40k fibrechannels

System specINL 1% typS/N 48dB typBW>70 MHz

Page 5: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

Implementation: Technology choice (1996)Implementation: Technology choice (1996)

• Developed analogue link system first (most links + most difficult)

Requirement Technology choice

Linearity Edge emitting Laser

Dynamic Range Single mode system, 1310nm wavelength

Settling Time Fast electronics (CMOS-Sub)

Gain 10bit ADC with equalization

Magnetic Field Non-magnetic connectors and packages

Radiation Extensive qualification of COTS-based components

Density

Low massSemi-customized laser package

Fibre ribbon & array connectors

Customized multi-ribbon cable

Semi-customized Rx-module

• Control link and ECAL readout link developed later using many of same parts

Page 6: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

Implementation: Components (2000-02)Implementation: Components (2000-02)

ST/CERN-MIC/Kapsch/G&ASumitomo

Diamond

Ericsson

NGK Optobahn

Front-endoptohybrid

Distributedpatch panel In-line

patch panel

Cable

Back-end A-RX

Ericsson

Ericsson

• Many COTS/COTS-based parts • Each component also has CERN and supplier specification• Long procurement and qualification process, complicated logistics • Current status - production complete or very nearly complete for all parts• Collaboration including Perugia, Vienna, Minnesota university groups

Page 7: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

Charged hadron fluence (/cm2 over ~10yrs)(M. Huhtinen)

Requirements: radiation environmentRequirements: radiation environment• High Energy 7+7TeV• High rate

– Large radiation field• mainly pions (few hundred MeV) in Tracker

Page 8: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

COTS issues COTS issues

• Extensive use of commercial off-the-shelf components (COTS) in CMS optical links

– Benefit from latest industrial developments

• cheaper• reliable qualified devices

– However COTS not made for CMS environment

• no guarantees of long-life inside CMS

• validation testing of COTS mandatory before integration into CMS

LLD ASIC

RX40 ASIC Pin photodiodes

Laser diodes

Fibres

e.g. control links digital opto-hybrid

Page 9: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

Quality Assurance programmeQuality Assurance programme

Prototype sample validation

Pre-production Qualification

Pre-productionAdvance validation test (AVT)

Lot acceptance

FunctionalityRadiation hardness

FunctionalityRadiation hardnessReliability

Radiation hardnessReliability

Functionality

1995-2000

2000-2002

2003-2004

2003-2005

Integration2005-2006 Functionality

Page 10: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

Radiation testingRadiation testing• e.g. validation tests on lasers

irradiation irradiation

annealingageing

(in-system) lab tests Market Survey

(in-system) lab tests

• Measurements:– Damage: different sources, different T, bias– Annealing rates, acceleration factors– Wearout

• >500 laser samples tested in total

n irradiation

qualification

AVT

Page 11: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

• In-situ measurements allows confident extrapolation/comparison of accelerated tests– Avoid before/after tests unless damage kinetics understood– Few changes to test-procedure since 1997 for consistency

• Very similar system used for fibre and photodiodes

Irradiation test systemIrradiation test system

• Measurement setup (lasers)

Opticalreceiver

array

Currentgenerator

array

PC

Datalogger

GPIB

laser undertest

fibre

irradiation cellor oven

Page 12: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

SCK-CEN Co-60 2kGy/hr

underwater

Irradiation at SCK-CEN and UCLIrradiation at SCK-CEN and UCL

neutrons

deut

eron

sUCL (T2 source)~20MeV neutrons

flux ~ 5x1010n/cm2/s

Samples stackedinside cold box (-10°C)

Interested to use these sources?please contact me…

Page 13: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

Radiation Damage in lasers – 20MeV neutronsRadiation Damage in lasers – 20MeV neutrons

• A lot of damage from neutrons

– Increase in laser threshold current

– Decrease of laser efficiency

Typical L-I characteristics before and after 5x1014n/cm2

1000

800

600

400

200

0

Ou

tpu

t lig

ht

po

we

r, L

(W

)

50403020100

Current, I (mA)

before irrad

after 5x1014

n/cm2

25

20

15

10

5

0

thre

sho

ld in

crea

se (

mA

)

1.0 2.0 3.0 4.0

~20MeV neutron fluence (1014

n/cm2)

1.00

0.95

0.90

0.85

0.80

0.75

0.70

rela

tive e

fficiency, E

/E(0

)

efficiency

threshold

• Damage proportional to fluence– Degradation of carrier lifetime

• After 4.5x1014n/cm2

– Threshold increase ~20mA– Efficiency loss ~20%

• All wafers tested with this source in advance of final production (2002-2004)

– 300 lasers in total

Page 14: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

Laser damage mitigationLaser damage mitigation

• LLD specified to compensate for laser damage

• for threshold up to 45mA

– Recall worst-case CMS-Tracker

Ithr~5.3mA after 10 years

• Large safety margin

(almost 10x)

LLD ASIC Laser diodes

Page 15: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

Annealing in lasersAnnealing in lasers

• Significant amount of annealing

– Proportional to log(tanneal)

• distribution of activation energies for annealing

• Similar rate for efficiency

– damage mechanism same as Ithr

• Expect at least 70% annealing after 10 years

102 105103 104

1.0

0.8

0.6

0.4

frac

tion

of d

amag

e re

mai

ning

1.0

0.8

0.6

0.40.1 1 10 100

annealing time (hrs)

wafer E

threshold damage

efficiency damage

0.4

0.2

Page 16: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

Relative damage factors

Valduc 0.75MeV n (=1)

UCL 20MeV n (=4.5)

PSI 200MeV (=8.4)60Co (~0)

• Coverage of various parts of CMS particle energy spectrum– Pions most important

• Similar factors for other 1310nm InGaAsP/InP lasers

Damage different sourcesDamage different sources

• Laser threshold Ithr with different sources (averaged and normalized) (1998-2000)

Page 17: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

• Based on damage factors and annealing rate at close to -10°C

• Take worst-case– radius=22cm in Tracker– pion damage dominates

Ithr = 6mA in 10 years

E = 6% in 10 years

• Damage decreases rapidly with distance from beam interaction point

– ~50% at r=32cm

Laser damage prediction in CMS Tracker Laser damage prediction in CMS Tracker

• Even without thorough understanding, can predict damage evolution over a 10-year lifetime inside Tracker

80

60

40

20

0

dam

age

(% d

efec

ts le

ft a

fter

10

yrs)

1086420

LHC operating time (years)

LHC luminosity profile:

year 1: 10%year 2, 33%year 3, 66%

years 4-10, 100%

total damage annual components

Page 18: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

• leakage current and responsivity Fermionics InGaAs 80um diameter (1996-2000)

Photodiode leakage and responsePhotodiode leakage and response

• RX40 ASIC designed to compensate for damage– dc current offset up to 500uA – automatic gain control (signals of 10-500uA)

Page 19: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

Photodiodes - responsePhotodiodes - response

• Photocurrent (InGaAs, 6MeV neutrons, 1998)

1.0

0.5

0.01050

neutron fluence, (1014

n/cm2)

1.0

0.5

0.0

1.0

0.5

0.0Fermionics

Epitaxx (FI)

Epitaxx (BI) /Italtel

Tests A and B

Test B

Test C

• Significant differences in damage• depends mainly if front or back-

illuminated– front-illuminated better

Page 20: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

PD SEU PD SEU

• photodiodes in control links sensitive to SEU– Bit-errors in control commands, clock and trigger signals

• strong dependence upon particle type and angle

Page 21: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

Photodiode Single-event-upsetPhotodiode Single-event-upset

• Bit-error-rate for 80Mbit/s transmission with 59MeV protons in InGaAs p-i-n (D=80m)• (UC Louvain la Neuve, 2000)• 10-90 angle, 1-100W optical power • flux ~106/cm2/s (similar to that inside CMS Tracker)

10-12

10-10

10-8

10-6

10-4

10-2

100

Bit

-err

or-

rate

-30 -25 -20 -15 -10

Optical power amplitude at PD (dBm)

p+ (beam off)

p+ (59MeV, 90°)

p+ (59MeV, 45°+)

p+ (59MeV, 30°+)

p+ (59MeV, 10°+)

• Ionization dominates for angles close to 90

• nuclear recoil dominates for smaller angles

– Confirmed with neutron tests

• BER inside CMS Tracker similar to rate due to nuclear recoils

• should operate at ~100W opt. power

45° 10°90°beam

Page 22: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

Tests of fibre attenuationTests of fibre attenuation

• Gamma damage in various COTS single-mode fibres at 1310nm (1997-8)

Page 23: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

Fibre attenuation vs fluenceFibre attenuation vs fluence

• damage actually most likely due to background

• ‘Neutron’ damage (1997)

Page 24: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

Fibre annealingFibre annealing

• damage recovers after irradiation (e.g. gamma)

• Damage therefore has dose-rate dependence

Page 25: CERN/CMS optical links radiation damage

[email protected] www.cern.ch/cms-tk-opto RADWG 29-11-2005

ConclusionsConclusions

• We are building large systems of COTS (tele/datacoms) based optical links for CMS

• Challenges include• Radiation damage and reliability• Large number of parts and density of links• Low mass, non magnetic packages• Also long project timescale, procurement, logistics, manpower….

• Our approach – Extensive quality and reliability assurance program

• CMS radiation effects • Reliability (Bellcore standard GR 468)

– Build good relationships with suppliers and partners– Validation of sensitive parts (lasers, photodiodes, fibres) before production

• Prototypes, pre-production qualification, advance validation in production

– Compensation for damage effects built into system

• Production phase essentially complete – good confidence of reliability, large safety margins