8
CENTRE TESTING INTERNATIONAL S D S COMPANY NAME: Foshan Shunde Guangling Purification Material Factory ADDRESS : Beijiao Residents Committee Industrial Area, Beijiao Town, Shunde District, Foshan City, Guangdong, China SAMPLE NAME : Columnar activated carbon granule

CENTRE TESTING INTERNATIONAL · · Contact us:[email protected] · Date issuing SDS:July 24, 2013 · Sources:Provided by company. Title * Author: Administrator Created Date: 7/24/2013

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CENTRE TESTING INTERNATIONAL · · Contact us:REACH@cti-cert.com · Date issuing SDS:July 24, 2013 · Sources:Provided by company. Title * Author: Administrator Created Date: 7/24/2013

CENTRE TESTING INTERNATIONAL

S D S

COMPANY NAME: Foshan Shunde Guangling Purification Material Factory

ADDRESS : Beijiao Residents Committee Industrial Area, Beijiao Town,

Shunde District, Foshan City, Guangdong, China

SAMPLE NAME : Columnar activated carbon granule

Page 2: CENTRE TESTING INTERNATIONAL · · Contact us:REACH@cti-cert.com · Date issuing SDS:July 24, 2013 · Sources:Provided by company. Title * Author: Administrator Created Date: 7/24/2013

Page 1/7

Safety Data Sheet (SDS)According to Commission Regulation (EU) No 453/2010

Printing date 24.07.2013 Revision date 24.07.2013Version number 1

DR

1 SECTION 1: Identification of the substance/mixture and of the company/undertaking

· 1.1 Product identifier

· Product name: Columnar activated carbon granule· CAS number: 64365-11-3 (activated carbon)· Registration number: No registration number is given yet for this product.

· 1.2 Relevant identified uses of the substance or mixture and uses advised againstIdentified uses: Air purification.Uses advised against: No information available.

· 1.3 Details of the supplier of the safety data sheetSupplier: Foshan Shunde Guangling Purification Material FactoryAddress: Beijiao Residents Committee Industrial Area, Beijiao Town, Shunde District, Foshan City, Guangdong, ChinaE-mail: [email protected]: +86-757-26602561Fax: +86-757-26602561

· 1.4 Emergency telephone number +86-757-26602561

2 SECTION 2: Hazards identification

· 2.1 Classification of the substance or mixture· Classification according to Regulation (EC) No 1272/2008 [CLP]

The product is not classified according to the CLP regulation.

· Classification according to Directive 67/548/EEC [DSD] or Directive 1999/45/EC [DPD]The product is not classified as dangerous.

· Classification system:The classification is according to the latest editions of the EU-lists, and extended by company and literature data.

· 2.2 Label elements· Labelling according to Regulation (EC) No 1272/2008 [CLP] Void· Hazard pictogram(s): Void· Signal word: Void· Hazard statement(s): Void· Precautionary statements: Void

· 2.3 Other hazards No information available.· Results of PBT and vPvB assessment:· PBT: Not applicable.· vPvB: Not applicable.

(Contd. on page 2)

Page 3: CENTRE TESTING INTERNATIONAL · · Contact us:REACH@cti-cert.com · Date issuing SDS:July 24, 2013 · Sources:Provided by company. Title * Author: Administrator Created Date: 7/24/2013

Page 2/7

Safety Data Sheet (SDS)According to Commission Regulation (EU) No 453/2010

Printing date 24.07.2013 Revision date 24.07.2013Version number 1

Product name: Columnar activated carbon granule

(Contd. of page 1)

DR

3 SECTION 3: Composition/information on ingredients

· 3.1 Chemical characterization:· Description:

Product: consisting of the following components.---------------------------------------------------------------------------------------------------------------Name CAS No. EC No. Concentration(%)----------------------------------------------------------------------------------------------------------------Charcoal, activated 64365-11-3 264-846-4 75Ash - - 20Water 7732-18-5 231-791-2 5----------------------------------------------------------------------------------------------------------------

· Dangerous components: Void

4 SECTION 4: First aid measures

· 4.1 Description of first aid measures· General information: In all cases of doubt, seek medical attention.· Following inhalation:

Remove victim to fresh air and keep at rest in a position comfortable for breathing. Get medical advice/attention ifyou feel unwell.

· Following skin contact: Wash with plenty of soap and water. If skin irritation occurs: Get medical advice/attention.· Following eye contact:

IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do.Continue rinsing. If eye irritation persists: Get medical advice/attention.

· Following ingestion:Never give anything by mouth to an unconscious person. Call a POISON CENTER or doctor/physician if you feelunwell. Rinse mouth.

· Information for doctor: No information available.

· 4.2 Most important symptoms and effects, both acute and delayedMay cause irritation to eyes, respiratory system and skin.

· 4.3 Indication of any immediate medical attention and special treatment needed No information available.

(Contd. on page 3)

Page 4: CENTRE TESTING INTERNATIONAL · · Contact us:REACH@cti-cert.com · Date issuing SDS:July 24, 2013 · Sources:Provided by company. Title * Author: Administrator Created Date: 7/24/2013

Page 3/7

Safety Data Sheet (SDS)According to Commission Regulation (EU) No 453/2010

Printing date 24.07.2013 Revision date 24.07.2013Version number 1

Product name: Columnar activated carbon granule

(Contd. of page 2)

DR

5 SECTION 5: Firefighting measures

· 5.1 Extinguishing media· Suitable extinguishing agents: CO2, dry chemical powder, water spray.

· 5.2 Special hazards arising from the substance or mixture Carbon oxides, irritating and toxic fumes and gases.

· 5.3 Advice for firefighters Fire-fighters should wear appropriate breathing apparatus and protective equipment

6 SECTION 6: Accidental release measures

· 6.1 Personal precautions, protective equipment and emergency proceduresRefer to Section 8 for personal protective equipment. Ensure adequate ventilation. Remove all sources of ignition.

· 6.2 Environmental precautionsDo not allow material to be released into the soil, sewerage systems and surface water.

· 6.3 Methods and material for containment and cleaning upPick up mechanically. Sweep up and shovel. Keep in suitable, closed containers for disposal.

· 6.4 Reference to other sectionsSee Section 7 for information on safe handling.See Section 8 for information on personal protection equipment.See Section 13 for disposal information.

7 SECTION 7: Handling and storage

· 7.1 HandlingHandle in accordance with good industrial hygiene and safety practice. Use personal protective equipment asrequired. Do not get in eyes, on skin. Wash thoroughly after handling. Use this material with adequate ventilation.Avoid generate dust. Do not breath dust.

· 7.2 Conditions for safe storage, including any incompatibilitiesStore in cool place. Keep container tightly closed in a dry and well-ventilated place.Keep away from open flames,hot surfaces and sources of ignition.Store away from strong oxidizers.

· 7.3 Specific end use(s) No information available.

(Contd. on page 4)

Page 5: CENTRE TESTING INTERNATIONAL · · Contact us:REACH@cti-cert.com · Date issuing SDS:July 24, 2013 · Sources:Provided by company. Title * Author: Administrator Created Date: 7/24/2013

Page 4/7

Safety Data Sheet (SDS)According to Commission Regulation (EU) No 453/2010

Printing date 24.07.2013 Revision date 24.07.2013Version number 1

Product name: Columnar activated carbon granule

(Contd. of page 3)

DR

8 SECTION 8: Exposure controls/personal protection

· 8.1 Control parameters· Ingredients with limit values that require monitoring at the workplace:

The product does not contain any relevant quantities of materials with critical values that have to be monitored at theworkplace.

· DNELs No information available.· PNECs No information available.

· 8.2 Exposure controls· Appropriate engineering controls: Use local exhaust ventilation. Ensure adequate ventilation.· Respiratory protection: Use suitable respiratory protective device in case of insufficient ventilation.· Skin protection: Gloves not normally required. Avoid prolonged or repeated skin contact.· Eye and face protection: Wear chemical safety goggles to prevent eye contact.· Body protection: Protective work clothing

9 SECTION 9: Physical and chemical properties

· 9.1 Information on basic physical and chemical properties· General Information:

Appearance: Black solidOdour: OdourlessOdour threshold: Not available.

· pH-value: Not available.· Melting point/Melting range: Not available.· Boiling point/Boiling range: Not available.

· Flash point: Not applicable.

· Flammability (solid, gaseous): Not available.

· Auto-Ignition temperature: Not available.

· Decomposition temperature: Not available.

· Self-igniting: Not available.

· Danger of explosion: Product does not present an explosion hazard.

· Flammable limits:Lower: Not available.

(Contd. on page 5)

Page 6: CENTRE TESTING INTERNATIONAL · · Contact us:REACH@cti-cert.com · Date issuing SDS:July 24, 2013 · Sources:Provided by company. Title * Author: Administrator Created Date: 7/24/2013

Page 5/7

Safety Data Sheet (SDS)According to Commission Regulation (EU) No 453/2010

Printing date 24.07.2013 Revision date 24.07.2013Version number 1

Product name: Columnar activated carbon granule

(Contd. of page 4)

DR

Upper: Not available.· Oxidizing properties: No oxidising properties.

· Vapour pressure: Not applicable.

· Density: Not available.· Vapour density: Not applicable.· Evaporation rate: Not applicable.

· Solubility in/Miscibility with:Water: Not available.

· Partition coefficient (n-octanol/water): Not applicable.

· Viscosity:Dynamic: Not applicable.Kinematic: Not applicable.

· 9.2 Additional information Intensity (%) : 95 Sulfur capacity (mg/g): 800 Granularity (mm): 4 Filling density (g/L): 850

10 SECTION 10: Stability and reactivity

· 10.1 Reactivity No information available.

· 10.2 Chemical stability Stable under normal conditions of use, storage and transport.

· 10.3 Possibility of hazardous reactions No dangerous reactions known under normal use.

· 10.4 Conditions to avoid High temperature, heating, source of ignition. Incompatible materials.

· 10.5 Incompatible materials Strong oxidizing agents.

· 10.6 Hazardous decomposition products Carbon oxides, irritating and toxic fumes and gases.

11 SECTION 11: Toxicological information

· Acute toxicity: No data available.· Skin corrosion/irritation: No irritant effect.· Serious eye damage/irritation: No irritating effect.

(Contd. on page 6)

Page 7: CENTRE TESTING INTERNATIONAL · · Contact us:REACH@cti-cert.com · Date issuing SDS:July 24, 2013 · Sources:Provided by company. Title * Author: Administrator Created Date: 7/24/2013

Page 6/7

Safety Data Sheet (SDS)According to Commission Regulation (EU) No 453/2010

Printing date 24.07.2013 Revision date 24.07.2013Version number 1

Product name: Columnar activated carbon granule

(Contd. of page 5)

DR

· Respiratory or skin sensitization: No sensitizing effects known.· Specific Target Organ Toxicity (STOT): No information available.· CMR effects (carcinogenity, mutagenicity and toxicity for reproduction): No information available.

12 SECTION 12: Ecological information

· 12.1 Toxicity· Acquatic toxicity: No further relevant information available.

· 12.2 Persistence and degradability No information available.

· 12.3 Bioaccumulative potential No information available.

· 12.4 Mobility in soil No information available.

· 12.5 Results of PBT and vPvB assessment· PBT: Not applicable.· vPvB: Not applicable.

· 12.6 Other adverse effects No information available.

13 SECTION 13: Disposal considerations

· 13.1 Waste treatment methods· Recommendation:

Smaller quantities can be disposed of with household waste. Dispose in accordance with all applicable state/regionaland local laws and regulations.Dispose of waste according to local regulations. Assure conformity with all applicable regulations.

14 SECTION 14: Transport information

· 14.1 Land transport· ADR/RID class: Not regulated as dangerous goods.· UN-Number: Not applicable.

· 14.2 Maritime transport· IMDG Class: Not regulated as dangerous goods.· UN Number: Not applicable.

(Contd. on page 7)

Page 8: CENTRE TESTING INTERNATIONAL · · Contact us:REACH@cti-cert.com · Date issuing SDS:July 24, 2013 · Sources:Provided by company. Title * Author: Administrator Created Date: 7/24/2013

Page 7/7

Safety Data Sheet (SDS)According to Commission Regulation (EU) No 453/2010

Printing date 24.07.2013 Revision date 24.07.2013Version number 1

Product name: Columnar activated carbon granule

(Contd. of page 6)

DR

· Marine pollutant: Not marine pollutant

· 14.3 Air transport· ICAO/IATA Class: Not regulated as dangerous goods.· UN/ID Number: Not applicable.

· UN "Model Regulation": -

· 14.4 Environmental hazards: Not applicable.

· 14.5 Special precautions for user Not applicable.

· 14.6 Transport/Additional information: Not dangerous according to the above specifications.

· 14.7 Transport in bulk according to Annex II of MARPOL73/78 and the IBC Code Not applicable.

15 SECTION 15: Regulatory information

· 15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture--------------------------------------------------------------------------------------------------------------------------------------CAS No. EU EINECS USA TSCA Canada DSL Australia AICS Korea ECL China IECSC--------------------------------------------------------------------------------------------------------------------------------------64365-11-3 Listed Not listed Listed Listed Listed Listed--------------------------------------------------------------------------------------------------------------------------------------

· 15.2 Chemical safety assessment A Chemical Safety Assessment has not been carried out.

16 SECTION 16: Other informationThis information is based on our present knowledge. However, this shall not constitute a guarantee for any specificproduct features and shall not establish a legally valid contractual relationship.

· Relevant phrases: Not applicable.· Training hints: Provide adequate information, instruction and training for operators.

· Department issuing SDS: Centre Testing International· Contact us: [email protected]· Date issuing SDS: July 24, 2013· Sources: Provided by company.