Upload
others
View
5
Download
0
Embed Size (px)
Citation preview
SCHMIERANLAGEN
--
Su
bje
ct
to c
ha
ng
es w
ith
ou
t n
otice
PT-LM140513Leaflet dd: 05.03.2014
Replaces that of:
Page: 1/3
Centralized Lubrication System for greaseSpecial executionProgressive system for grease
VPB-BN
1) Stainless steel AISI 304 cabinet:- External dimensions : 600x1000x400mm;- Double door, electric panel and hydraulic components(Fig. 1 9)
2) Electric panel for pump working’s check and lubricant’slevel check (Fig. 2 5),
3) Woerner stainless steel progressive distributors seriesVPB-BN
Type of pump:
Application:
Customer !XXX MilanoLubrication system for 64 points (SKF ball bearings) of an Horizontal Belt Filter
GMF-C/7V/97/M/0/0/8/0/0/0/V/1/X
Type of progressive distributors :
:Special executions
÷
÷
Fig.2
Fig.1
MWM Schmieranlagen Srl
Via G.Galilei 4B I-20068 Peschiera Borromeo (Mi)
Tel:+39 02 54 75 311 Fax +39 02 551 948 78website://www.mql.it e-mail: [email protected]
Fig.1
Page 2/3MWM Schmieranlagen Srl
Via G.Galilei 4B I-20068 Peschiera Borromeo (Mi)
Tel:+39 02 54 75 311 Fax +39 02 551 948 78website://www.mql.it e-mail: [email protected]
Fig.3
Fig.4
Fig.5
SCHMIERANLAGEN
Details of control lights
- Power
- Failure: lubricant level or pump’s motorovertension
PT-LM140513
SCHMIERANLAGEN
Fig.1
MWM Schmieranlagen Srl
Via G.Galilei 4B I-20068 Peschiera Borromeo (Mi)
Tel:+39 02 54 75 311 Fax +39 02 551 948 78website://www.mql.it e-mail: [email protected]
Fig.7
Fig.8
Fig.6
Fig.9
Details of pump’s housing equipped with removable grease tray (for grease collection, from checking valves, in case of overpressure on pumping elements).
- C
on
ris
erv
a d
i m
od
ific
he
se
nza
pre
avvis
o -
PT-LM140513Page 2/3
SC
HM
IER
AN
LA
GE
N
MW
MS
ch
mie
ra
nlage
nS
rl
Via
G.G
alilei4
BI-2
00
68
Pesc
hie
raB
orro
meo
(Mi)
Tel:+3
90
25
47
53
11F
ax+3
90
25
51
94
87
8w
ebsi
te:/
/ww
w.m
ql.it
e-m
ail:
info
@m
ql.it
LM
140513
Dra
win
g 3
Of
3F
ollow
s -
Da
te
05
/02
/20
14
De
sig
ne
r
2M
ELE
CT
RIC
PA
NE
L
SE
010714_F
LS
mid
th
SCHMIERANLAGENMinimal Lubrication TechnologiesMWM Schmieranlagen
Page 1/1
Programming and set-up instructions:
- Functional parameter modification
Only a qualified person can change the functionalparameters.
- Fault signals
Functional parameters which can be changed are:
Pump inactive time
To modify parameters carry out following operations:Press A+B for 3 seconds at least to activate changingmode;
Press + o - to select the parameter you need to modifyOFF:
hours/minutesPress OK to confirm the choice;Press + o - to increase or decrease the value;Press OK to confirm the selected value;Press ESC to exit the changing mode and return to theprevious screen .
values
Full scale values of hours is presetted in a range from 0to 32.767.The system automatically returns to the previous screenafter 3 minutes, from the access to the changing mode,without an exit confirmation (ESC).
The system gives a fault signal if
Alarm output O4 (OUT4) is presetted NC, therefore thesignal is interrupted in case of fault. It is possible to useoutput O3 (OUT3) as NO, the signal is closed in case offault.
After checking and resolving the fault problem, pressESC.
1) Pump active time;2) .
-
-(PUMP ON: hours/minutes; PUMP
);----
Full scale of minutes is presetted in a range from1 to 59.
:- grease reachs the minimal level;- electric fault of either pump’s motor or contactor.
- Reset ( only contactor)
Functional Parameters Screen
Fig. 4
Minimal Level Fault Signal
Fig. 5
Pump On Screen
Pump Off Screen
Electric Fault Signal
MWM Schmieranlagen Srl
Via G.Galilei 4B I-20068 Peschiera Borromeo (Mi)
Tel:+39 02 54 75 311 Fax +39 02 551 948 78website://www.mql.it e-mail: [email protected]
Pu
mp
ing
ele
me
nt
Me
tere
d
qu
an
tity
gr
Re
gu
lati
on
pu
mp
ing
ele
me
nt
Me
tere
d v
olu
me
%
Ty
pe
of
Pro
gre
ssiv
e
Dis
trib
uto
r
Pa
rts
List
Po
siti
on
LM1
40
51
3
Dra
win
g p
osi
tio
n
31
01
41
.27
64
-3A
Typ
e o
f b
ea
rin
gQ
ua
nti
tyP
oin
ts
18
05
no
tch
s2
7%
VP
B-B
N/8
/0/0
/0/0
9/0
9/0
9/0
9/V
2
50
58
x Ø
40
10
gr
8
28
05
no
tch
s2
7%
VP
B-B
N/8
/0/0
/0/0
9/0
9/0
9/0
9/V
2
50
58
x Ø
40
10
gr
8
38
05
no
tch
s2
7%
VP
B-B
N/8
/0/0
/0/0
9/0
9/0
9/0
9/V
2
50
58
x Ø
40
10
gr
8
42
80
ma
x (1
8 n
otc
hs)
10
0%
VP
B-B
N/1
0/0
/0/0
/20
/09
/20
/20
/20
/V
23
03
+0
5 8
x Ø
40
+ 1
xØ2
00
(8x1
0)+
20
09
52
10
14
no
tch
s7
8%
VP
B-B
N/1
2/0
/0/0
/20
/20
/20
/20
/20
/20
/V
22
02
+0
6 6
x Ø
40
+ 1
xØ1
80
(6x1
0)+
15
07
Gre
ase
qu
an
tity
an
d R
eg
ula
tio
n p
um
pin
g e
lem
en
ts
Lub
rica
tio
n p
oin
ts
typ
e q
ua
nti
ty
52
10
14
no
tch
s7
8%
VP
B-B
N/1
2/0
/0/0
/20
/20
/20
/20
/20
/20
/V
22
02
+0
6 6
x Ø
40
+ 1
xØ1
80
(6x1
0)+
15
07
62
20
14
no
tch
s7
8%
VP
B-B
N/6
/0/0
/0/1
4/2
0/2
0/V
24
04
+0
6 6
x Ø
40
+ 2
xØ1
10
8
78
05
no
tch
s2
7%
VP
B-B
N/8
/0/0
/0/0
9/0
9/0
9/0
9/V
2
50
58
x Ø
40
10
gr
8
88
05
no
tch
s2
7%
VP
B-B
N/8
/0/0
/0/0
9/0
9/0
9/0
9/V
2
50
58
x Ø
40
10
gr
8
To
tal
64
Typ
e o
f b
ea
rin
gg
rLu
bri
cati
on
po
ints
Be
ari
ng
s Ø
40
mm
10
60
Be
ari
ng
s Ø
11
0 m
m8
02
Be
ari
ng
si Ø
18
0 m
m1
50
1
Be
ari
ng
s Ø
20
0 m
m2
00
1
To
tal
64
For
exa
mp
le 2
50
min
* 1
,12
cm
3 =
28
0 g
r
Re
qu
ire
d g
rea
se q
ua
nti
ty -
An
nu
al r
eq
uir
em
en
tsFl
ow
fo
r e
ach
pu
mp
ing
ele
me
nt:
1,1
2 c
m3
/min
For
exa
mp
le:
10
lub
rica
tio
n c
ycle
s p
er
yea
r -
25
min
ute
s
Pu
mp
's w
ork
ing
tim
e:
25
0 m
in
Mat.: S
tain
less s
teel
AIS
I304
SC
HM
IER
AN
LA
GE
N
UN
I E
N 2
27
68
-1
Gra
do
FIN
E
To
lle
ran
ze
:
n°
De
scrizio
ne
mo
dific
aa
uto
red
ata
SE
CT
ION
VIE
WS
WIT
HO
UT
DO
OR
S
AN
D S
HE
ET
ME
TA
LB
AS
ES
H1
00
SH
EE
TM
ETA
L
AD
JU
STA
BLE
IN
DE
PT
H
522m
m X
320 m
m
SH
EE
TM
ETA
L
DIV
IDE
R
RE
MO
VA
BLE
GR
EA
SE
TR
AY
H18m
m
AA
B B
73,5
100
182
SE
CT
ION
A-A
SE
CT
ION
B-B
Sh
ee
t 2
/2
180
38
350
M8 N
°4
Sp
ecia
l sta
inle
ss s
tee
l ca
bin
et
MW
M C
od
e F
90
47
01
Dra
win
gD
Q 0
34
11
4
Desig
ner:
Cla
udio
Are
zzi
Date
: 17/0
1/2
014
-S
ubje
ctto
changes
withoutany
notice
-
Test Report Nr.
Unit type: MWM-LM 140153
Leaflet date: 19.02.2014Replaces that of:page: 1
PC: MWM_Unit_LM140513
Customer:
Order Nr. :
Date of the order:
Requested delivery:
Test procedure:
Functional checks:
1) Check electrical wirings
2) Pump Working check
3) Check Level switch
4)
5) Fault signal:
- level fault
- motor relais
Test Operator:
Start test: time: date:
Stop test: time: date:
Total testing time:
Components:
-
Registration Nr: 261914-__ 2014/2
Woerner Pump type:PMF-B.B/7V/97/M/0/0/8/0/0/0/V/1/0
Accessories:
- Binary level switch ON-OFF type:Li5142 L=273 mmwith climatic Tube E43100L=264 mm
- Control and monitoring el. unit:MWM LM 140515 with PLC
PLC software: F305060
- Special stainless steel cabinetMWM Design DQ 034114
CG
DP
Notes:
Minimal Lubrication TechnologiesMWM Schmieranlagen
MWM Schmieranlagen Srl
Via G.Galilei 4B I-20068 Peschiera Borromeo (Mi)
Tel:+39 02 54 75 311 Fax +39 02 551 948 78website://www.mql.it e-mail: [email protected]
1XX-VV
Customer-Milano
1
17.12.2013
20.02. 2014
MN
PLC Software running