5
Centara Grand Mirage Hotel Power Quality improvement Case Study Speaking of Thailand, the first thing that comes to mind is the sun, beaches, variety of fruits, and popular tourist punching places...Thailand is an important strategic fulcrum country of the "Belt and Road". With the rapid development of many industries such as Thailand's automobile manufacturing, clothing and tourism, Thailand's electricity demand continues to grow. Jiangsu Sfere Electric responds to the national strategy of "going global" and actively explores the international market. Project introduction Centara Grand Mirage is the largest theme hotel in Pattaya. It has 555 guest rooms, many equipments, large power consumption and high requirements for power quality.

Centara Grand Mirage Hotel Power Quality improvement Case Study

Embed Size (px)

DESCRIPTION

Jiangsu Sfere Electric responds to the national strategy of "going global" and actively explores the international market.

Citation preview

Page 1: Centara Grand Mirage Hotel Power Quality improvement Case Study

Centara Grand Mirage Hotel Power Quality improvement Case Study

Speaking of Thailand, the first thing that comes to mind is the sun, beaches,

variety of fruits, and popular tourist punching places...Thailand is an important strategic fulcrum country of the "Belt and Road". With the rapid development

of many industries such as Thailand's automobile manufacturing, clothing and tourism, Thailand's electricity demand continues to grow. Jiangsu Sfere

Electric responds to the national strategy of "going global" and actively

explores the international market.

Project introduction

Centara Grand Mirage is the largest theme hotel in Pattaya. It has 555 guest rooms,

many equipments, large power consumption and high requirements for power

quality.

Page 2: Centara Grand Mirage Hotel Power Quality improvement Case Study

The hotel has 4 transformers with a capacity of 2000kVA, the natural power factor is

about 0.8, the load factor of the 4 transformers is basically the same, and the

capacity of the non-linear equipment is small. Based on the above situation, the

hotel is equipped with Sfere SFR-L series stainless steel shell smart capacitor 600

kvar for each transformer. Our equipment quickly responds to load and reactive

power requirements after operation, ensuring that the hotel's monthly average

power factor is ≥0.95, while reducing the flow of reactive power in the power supply

system, it also reduces electricity costs and improves voltage stability .

Program features 1. Reactive power compensation module zero-crossing switching, fast response

speed and small inrush current.

Inrush test

■Adopt semiconductor electronic switch and compound switch (MCU CPU

control+Magnetic holding relay) The inrush current of switching capacitor should be

limited to less than 5 times of rated current of capacitor: 216 (A)

■The inrush current of capacitor switched by electromechanical switch shall be

limited to less than 100 times of rated current of the capacitor: / (A)

Page 3: Centara Grand Mirage Hotel Power Quality improvement Case Study

Test times: 3 times (input at peak)

1ST Peak inrush current 100.6A

2nd Peak inrush current 98.8A

3RD Peak inrush current 96.0A

2. The reactive power compensation controller sends switching commands

through the network port. The controller and several compensation modules are

connected hand in hand with network cables. The wiring workload of the control

part is greatly reduced, and the number of fault points is significantly reduced.

3. The stainless steel shell of the reactive power compensation module is more suitable for

environments with high humidity, safe and stable. Thailand's high temperatures throughout the

year, often has tropical cyclones generated by the ocean, the average humidity generally falls

Page 4: Centara Grand Mirage Hotel Power Quality improvement Case Study

between 75-100%.

4. The reactive power compensation module has a compact structure, which saves the

user's power distribution room space. Easy to install and maintenance.

5. The reactive power compensation module has high reliability and supports ≥ 1.2 million

times switching.

Test Result

Page 5: Centara Grand Mirage Hotel Power Quality improvement Case Study

Operating cycles: 1.2 million times

Operating frequency: 1 200 times/h

After the test, the electrical appliances shall be free of electrical and mechanical failures, and no

contact welding or continuous arcing or fuse blowing shall occur.

Meet the requirements

Thailand is one of the top ten tourist destinations in the world and the country that receives the

most international tourists among ASEAN countries. In recent years, the Thai government has

formulated a tourism development plan and adopted a series of encouraging and supporting

policy measures to vigorously build and improve tourism infrastructure.

At the same time, Thailand’s power infrastructure is relatively good, and the Thai power market

is relatively complete among Southeast Asian countries. With the hotel power management

solution, the hotel can greatly improve the normal operation time and efficiency of the electrical

system, save energy and increase efficiency, and ensure safety and reliability at the same time.