Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270

with Industrial Metering Unit (IMU-DC) Option

User Manual

November 2010

Revision F Honeywell

Page 2: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.comii

Page 3: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

iii ii

This product contains a radio-frequency transmitter, Motorola Model g18, FCC ID # IHDT6AC1,

Motorola Model g20, FCC ID # IHDT56DB1, Motorola Model g24, FCC ID # IHDT56FV2

Motorola Model c18, FCC ID # IHDT56CW1 or Motorola Model iO270, FCC ID # AZ489FT7011

The combined cable loss and antenna gain must not exceed +6.8 dBi (850

band), +1.9 dBi (900 band), +7.7 dBi (1800 band) and +2.2 dBi (1900 band). Total system output must not exceed 2.0W EIRP in the 1900 band in order to comply with the EIRP limit of 24.232. The antenna installation must provide a minimum separation distance of 20cm (8”) from users and nearby persons and

must not be collocated or operating in conjunction with any other antenna or transmitter.

See Chapter-12 for more safety information.

WARNING No hazardous area safety approvals have been

issued for this product. It is therefore necessary to ensure that the product is only installed at locations that are classified as ‘safe area’ sites.

See Chapter-12 for more safety information.

COPYRIGHT 2009 by Mercury Instruments LLC

All rights to this document, domestic and international, are reserved by Mercury Instruments. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise) without the prior written permission of Mercury Instruments. Requests for permission to reproduce or distribute this manual should be addressed to:

MERCURY INSTRUMENTS LLC MELBOURNE OPERATIONS

305A EAST DRIVE MELBOURNE, FLORIDA, USA 32904

Page 4: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.comiv

iv

COMMON QUESTIONS

What does this device do? The CNI can count electrical pulses from two independent, external sources. A pulse could represent any measurable quantity such as a volume of gas, a kilowatt of electricity or an item dispensed from a vending machine. The CNI counts these pulses over a predetermined period of time and then saves the total count in its memory as one record. It then starts over for the next time period and continues this process for hours, days or weeks at a time. At regular intervals the CNI establishes a radio link with a cellular telephone service provider and transmits this information to a central computer system for processing. This can be accomplished with a circuit-switched data (CSD) connection to an analog modem at the computer site. Or the CNI can exchange data with an Internet server running on that computer. Mercury provides a powerful application program called “DC-2009” which can process calls from thousands of devices, store their data in a database and present the results to user in a variety of formats. The CNI can also monitor several external and internal signals that might indicate alarm conditions, such as device tampering, excessive pressure, loss of power, etc. The CNI can be programmed to place an immediate call when any of these conditions occur. In addition to monitoring alarm conditions and counting pulses any device with a standard RS-232 serial port can be connected to the CNI. In a special mode the CNI can act as a transparent link between the device and the central computer system. This is only supported in CSD mode. What equipment can be used with the CNI? The pulse and alarm inputs can be connected to normally open switch contacts, such as relays, reed switches or open-collector semiconductor devices such as transistors. The CNI cannot accept signals that can source current, such as an output from an amplifier. Nearly any device that has a serial RS-232 port can be connected to the CNI’s serial port. A minimum of three wires is needed to carry data between the two units. Baud rates from 300 to 9600 are supported. Using an optional adapter board called a “dual-port multiplexer” two separate RS-232 devices can be connected to the same CNI. The devices do not have to be similar to each other and can operate at different baud rates.

The Cellular Network Interface is simply referred to as the “CNI” throughout this document. This unit’s operating software allows it to behave as a legacy

data collection device known as an Industrial Metering Unit, or “IMU”.

Page 5: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

v v

Does the CNI use a cell phone? The cellular radio module is similar to that used in a digital cellular phone, but there is no display, keypad, speaker or microphone. Instead it has a communications port that allows the CNI’s processor to control the radio and use it as a wireless modem. Also, the radio is designed for more severe environmental conditions than a commercial cell phone. There are references within this document to “mobile” devices because the cellular radio system was intended to support portable phones and equipment. Though the CNI is normally installed in a fixed location, it is still classified as a “mobile” device. How is the CNI packaged? The CNI itself is a small circuit board assembly containing a processor, memory, a serial communications port, a cellular radio module and an antenna. This device requires a dc power source in the range of 9 to 28 volts. The CNI circuit board can be purchased by itself and mounted within your remote device or in a separate enclosure. Mercury offers an inexpensive enclosure that can be mounted to a wall and provides adequate protection from common environmental conditions. Mercury also offers complete packages that include the CNI, various power supply options and robust weatherproof enclosures. These configurations are discussed near the end of this document. Does it matter where the CNI is installed? Yes. For outdoor applications the CNI should be mounted inside an enclosure that can withstand wide variations in temperature and humidity, as well as provide protection from insects and direct contact with water. Since the CNI contains its own antenna, metal enclosures cannot be used because they will block the radio signals. However, an external antenna can be used in applications that require metal enclosures, or in areas in which the radio signals are weak. Also, and this is very important, although the equipment that will be attached to the CNI may be allowed to operate in hazardous areas, the CNI itself must not be installed in any area classified as hazardous. The two devices are connected together with a 3- to 6-conductor cable carrying low-voltage signals and can be separated by enough distance to accommodate most installations. The use of safety barriers may be necessary. Is the CNI ready to use immediately? No, there are four important steps before the CNI can be put into service:

1) Any external equipment, including things like a solar panel, must be wired to the CNI 2) You must purchase cellular phone service. 3) You must configure the CNI using a computer and a special program and cable from

Mercury. 4) The data collection software supplied by Mercury (DC-2009) must be supplied with

information about the CNI.

Page 6: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.comvi vi

How do I purchase cellular service? As with any cellular phone, you must purchase cellular service. There are several different digital technologies used today. When you purchase a personal cell phone, you generally choose a provider that has the best calling plan and coverage in the area you live or work. You then receive a phone that works with their technology. The CNI is designed to support GSM, CDMA or iDEN cellular technology. Though all service providers support voice calls, not all of them may support the exchange of data. Therefore it is necessary to locate a service provider that supports either circuit-switched data (CSD) connections or Internet connections.

Why must the CNI be configured? When the CNI places a cellular call, it must have a phone number to dial or an Internet address to contact, instructions about what to do if the line is busy, what baud rate to use, etc. Each CNI must also be assigned a unique ID number. The CNI is configured using your computer and a special cable and software supplied by Mercury. This can be done any time before, during or after installation. What does the DC-2009 data collection software do? Mercury’s data collection software, DC-2009, has the ability to process calls from, or place calls to thousands of units per hour. Each CNI can be scheduled to call in at specific times throughout the day, or once a week or once a month. The data collection software can process the CNI’s information in many different ways, depending upon the customer’s needs. It can also notify the customer immediately when an alarm condition occurs. To do this properly, each unit must be registered with the software. What is the difference between CSD and Packet Service? When the CNI places or receives a CSD (circuit-switched data) call, it will be communicating with an analog modem that is tied to a wired telephone line. The cellular service provider has banks of modems available in its switching centers. When it detects a CSD call, it connects one of its own modems to the wired line. Data is transferred between the CNI and the switching center over the radio link, and then between the switching center and the destination modem over wire. Like a voice call, a CSD call is generally billed by the minute. Some service providers may only support “mobile-originate” calls, meaning the CNI can place a call to the central computer but cannot be called. Cellular service providers may offer access to the Internet using a service generally called “packet service”. Data is exchanged in small blocks, or packets, to a server running Mercury’s DC-2009 software. A packet call is generally billed by the amount of data exchanged rather than by the minute. Service is generally purchased in increments of 1 million bytes (1Mb) per month. Packet service has the advantage of being able to retrieve data from any CNI regardless of how far away the unit is from the central computer, without the expense of long-distance phone calls.

Page 7: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

vii vii

TABLE OF CONTENTS

1 PRODUCT DESCRIPTION ....................................................................................1-1 1.1 Product Overview ............................................................................................1-1 1.2 DC-2009 Data Collection System....................................................................1-2 1.3 CSD versus Packet (Internet) Mode................................................................1-2

1.3.1 CSD Mode ..............................................................................................1-2 1.3.2 Packet (Internet) Mode ...........................................................................1-4

1.4 Communications Scenarios.............................................................................1-5 2 INSTALLATION.....................................................................................................2-1

2.1 Unpacking, Damage reports, Item List ............................................................2-1 2.2 Additional Items Required for Installation........................................................2-1 2.3 Site Selection for Best Performance ...............................................................2-2 2.4 CNI Board Revisions .......................................................................................2-4 2.5 Model GSM18 Layout......................................................................................2-7 2.6 Model GSM20 Layout......................................................................................2-8 2.7 Model CDMA18 Layout ...................................................................................2-9 2.8 Model iDEN270 Layout .................................................................................2-10 2.9 CNI Block Diagram........................................................................................2-11 2.10 Circuit Board Dimensions and Mounting Hole Pattern ..................................2-12 2.11 Power Supply Requirements.........................................................................2-13 2.12 Wiring External Devices to the CNI’s Communications Port .........................2-14 2.13 Installing the Optional Dual-Port Multiplexer .................................................2-15 2.14 Using the CNI’s Alarm Inputs ........................................................................2-19 2.15 External Antennas .........................................................................................2-20 2.16 Using the Power Fail Input ............................................................................2-21 2.17 Supplying Backup Power to the CNI .............................................................2-21 2.18 Quick Power-Up Check .................................................................................2-23

3 CELLULAR SERVICE ...........................................................................................3-1 3.1 GSM Service ...................................................................................................3-1

3.1.1 GSM Overview .......................................................................................3-1 3.1.2 Establishing Cellular Service for GSM GPRS Packet Service ...............3-1 3.1.3 Establishing Cellular Service for GSM CSD ...........................................3-2 3.1.4 SIM Card Installation for the GSM18......................................................3-3 3.1.5 SIM Card Installation for the GSM20......................................................3-4 3.1.6 Requesting a Voice Phone Number or SMS Service .............................3-5

3.2 CDMA Service.................................................................................................3-5 3.2.1 CDMA Overview .....................................................................................3-5 3.2.2 Establishing Cellular Service for CDMA 1XRTT Packet Service............3-5 3.2.3 Establishing Cellular Service for CDMA CSD.........................................3-6 3.2.4 Requesting a Voice Phone Number or SMS Service .............................3-7 3.2.5 Over-the-Air Activation ...........................................................................3-8

3.3 iDEN Service ...................................................................................................3-8 3.3.1 iDEN Overview .......................................................................................3-8 3.3.2 Establishing Cellular Service for iDEN Packet Service ..........................3-8 3.3.3 Establishing Cellular Service for iDEN CSD...........................................3-9 3.3.4 SIM Card Installation for the iDEN270....................................................3-9 3.3.5 Requesting a Voice Phone Number or SMS Service ...........................3-11

4 CONFIGURATION USING MERCURY PROGRAMMER (MP32).........................4-1 4.1 Programmer Cable ..........................................................................................4-1

Page 8: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.comviii

viii

4.2 MP32 Software Startup ...................................................................................4-1 4.3 Main Configuration Screen..............................................................................4-4

4.3.1 Remote Unit ID .......................................................................................4-5 4.3.2 Destination..............................................................................................4-5 4.3.3 Originate Calls ........................................................................................4-5 4.3.4 Respond to Voice Calls ..........................................................................4-5 4.3.5 Respond to SMS ....................................................................................4-5 4.3.6 Maintain Internet Connection..................................................................4-5 4.3.7 Dual Port.................................................................................................4-6 4.3.8 Firmware Version ...................................................................................4-6 4.3.9 Primary Call Retry Rate..........................................................................4-6 4.3.10 Primary Call Retry Count........................................................................4-6 4.3.11 Secondary Call Retry Interval.................................................................4-6 4.3.12 Counter/Status Input-1 ...........................................................................4-7 4.3.13 Counter/Status Input-2 ...........................................................................4-7

4.4 Serial Port-1 Screen ........................................................................................4-8 4.4.1 Port Select ID .........................................................................................4-8 4.4.2 Max BPS.................................................................................................4-8 4.4.3 Data Bits .................................................................................................4-9 4.4.4 Parity Type .............................................................................................4-9 4.4.5 Stop Bits .................................................................................................4-9

4.5 Serial Port-2 Screen ........................................................................................4-9 4.6 Cellular Settings Screen................................................................................4-10

4.6.1 Service Type.........................................................................................4-10 4.6.2 PIN Number (GSM and iDEN only) ......................................................4-10 4.6.3 Frequency (GSM18 only) .....................................................................4-11 4.6.4 GPRS Access Point Name (GSM only)................................................4-11 4.6.5 Packet Service Connection Command (GSM and CDMA only) ...........4-11 4.6.6 OTAA Programming Number (CDMA only) ..........................................4-11 4.6.7 PAP User Name and Password ...........................................................4-12

4.7 Programming the CNI....................................................................................4-12 5 DC-2009 DATA COLLECTION SYSTEM..............................................................5-1

5.1 Introduction......................................................................................................5-1 5.2 Setting up the IMU Server for PACKET connections ......................................5-1 5.3 Setting up DC-2009 for CSD connections.......................................................5-3 5.4 Setting up a Call Schedule ..............................................................................5-5 5.5 Defining the CNI ..............................................................................................5-8 5.6 Starting the data collection process ..............................................................5-16

6 CNI OPERATION...................................................................................................6-1 6.1 Call Retry Strategy ..........................................................................................6-1 6.2 Paging via Voice Call ......................................................................................6-1 6.3 Paging via SMS Message ...............................................................................6-2 6.4 What Causes the CNI to Call In? ....................................................................6-2

6.4.1 Alarm Condition ......................................................................................6-2 6.4.2 Paging ....................................................................................................6-2 6.4.3 Scheduled Call .......................................................................................6-2

6.5 Behavior when Originating a Call in CSD Mode..............................................6-3 6.6 Behavior when Answering a Call or Page in CSD Mode.................................6-4 6.7 Behavior in Packet Mode ................................................................................6-5 6.8 Permanent (“Always On”) Internet Connection ...............................................6-6 6.9 Transparent Mode for Alarm Status and Maintenance....................................6-7

Page 9: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

ix

ix

6.10 Transparent Mode for One External Serial Device..........................................6-8 6.11 Transparent Mode for Two External Serial Devices........................................6-9 6.12 Power Failure Standby Mode ........................................................................6-10 6.13 Over-the-Air Activation (CDMA18 only).........................................................6-10

7 Battery-Operated Unit Assembly ........................................................................7-1 7.1 Description ......................................................................................................7-1 7.2 Unpacking, Damage reports, Item List ............................................................7-2 7.3 Unit Assembly Dimensions..............................................................................7-3 7.4 Electrical Wiring Diagram ................................................................................7-4 7.5 Power Supply Board........................................................................................7-5 7.6 Lead Acid Battery Installation..........................................................................7-7 7.7 External Antenna Kit........................................................................................7-8 7.8 TAMPER Alarm ...............................................................................................7-8 7.9 Low Battery Alarms .........................................................................................7-8 7.10 Notes About Battery Life .................................................................................7-8

8 AC-Powered (“Configuration-1”) Unit Assembly ..............................................8-1 8.1 Description ......................................................................................................8-1 8.2 Unpacking, Damage reports, Item List ............................................................8-1 8.3 Unit Assembly Dimensions..............................................................................8-2 8.4 AC Power Cable Wiring Connection ...............................................................8-4 8.5 AC Voltage Selection ......................................................................................8-5 8.6 Lithium Backup Battery Installation .................................................................8-6 8.7 Electrical Wiring Diagram ................................................................................8-8 8.8 Power Supply Board........................................................................................8-9 8.9 Wiring External Devices to the CNI Board ....................................................8-11 8.10 External Antenna Kit......................................................................................8-12 8.11 TAMPER Alarm .............................................................................................8-13 8.12 Low Battery Alarms .......................................................................................8-13

9 AC-Powered (“Configuration-2”) Unit Assembly ..............................................9-1 9.1 Description ......................................................................................................9-1 9.2 Unpacking, Damage reports, Item List ............................................................9-1 9.3 Unit Assembly Dimensions..............................................................................9-2 9.4 Electrical Wiring Diagram ................................................................................9-3 9.5 Power Supply Board........................................................................................9-4 9.6 AC Mains Power Supply Connection ..............................................................9-5 9.7 Installing or Replacing the Rechargeable Battery ...........................................9-6 9.8 External Antenna Kit........................................................................................9-7 9.9 TAMPER Alarm ...............................................................................................9-7 9.10 Low Battery Alarms .........................................................................................9-7 9.11 Notes About Battery Life .................................................................................9-7

10 Solar-Powered Unit Assembly ......................................................................10-1 10.1 Description ....................................................................................................10-1 10.2 Unpacking, Damage reports, Item List ..........................................................10-1 10.3 Unit Assembly Dimensions............................................................................10-2 10.4 Electrical Wiring Diagram ..............................................................................10-3 10.5 Solar Power Supply Board ............................................................................10-3 10.6 Solar Panel Installation..................................................................................10-4

10.6.1 Setting the Proper Solar Panel Tilt Angle .............................................10-4 10.6.2 Selecting the Appropriate Gauge Power Cable....................................10-6 10.6.3 Routing the Solar Panel’s Cable to the Power Supply Board...............10-8

10.7 Routing the External Device Cables to the CNI ............................................10-9

Page 10: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.comx

x

10.8 External Antenna Kit......................................................................................10-9 10.9 TAMPER Alarm ...........................................................................................10-10 10.10 Low Battery Alarms .....................................................................................10-10 10.11 Notes About Battery Life .............................................................................10-10

11 Flat Pack Unit Assembly................................................................................11-1 11.1 Description ....................................................................................................11-1 11.2 Enclosure Dimensions...................................................................................11-2 11.3 Electrical Wiring Diagram ..............................................................................11-5 11.4 CALL Switch (Optional) .................................................................................11-6 11.5 Dual Port Multiplexer (Optional) ....................................................................11-6 11.6 Backup Battery Pack (Optional) ....................................................................11-6 11.7 Main Power Failure Detector Module (Optional) ...........................................11-7

12 SAFETY, HAZARDOUS AREAS, ESD PRECAUTIONS ................................12-9 12.1 Safety ............................................................................................................12-9 12.2 ESD Handling Precautions..........................................................................12-10

13 TECHNICAL SPECIFICATIONS .....................................................................13-1 14 ASCII-HEX-DECIMAL CONVERSION CHART...............................................14-1 15 WARRANTY INFORMATION ..........................................................................15-1

Page 11: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

xi xi

LIST OF TABLES

CNI Rev A, B and C Jumper Configurations..................................................................2-4 CNI Rev-D and E Jumper Configurations ......................................................................2-6 CSD Transparent Mode Status Commands ..................................................................6-8 Latitude versus Tilt Angle.............................................................................................10-5 Resistance of Wire.......................................................................................................10-7

LIST OF FIGURES

Data Logger System using the Internet .........................................................................1-5 CNI Board Revisions A, B or C ......................................................................................2-4 CNI Board Revisions D and E........................................................................................2-5 Primary Components of the Model GSM18 ...................................................................2-7 Primary Components of the Model GSM20 ...................................................................2-8 Primary Components of the Model CDMA18.................................................................2-9 Primary Components of the Model iDEN270 ...............................................................2-10 Block Diagram of the CNI ............................................................................................2-11 CNI Physical Dimensions.............................................................................................2-12 Minimum Connection of an External Device to the CNI ...............................................2-14 Dual Port Multiplexer Board .........................................................................................2-15 Installed Dual Port Multiplexer Board...........................................................................2-16 Externally-Mounted Dual Port Multiplexer Board .........................................................2-17 Typical Wiring of Two Serial Devices to the Multiplexer Board....................................2-18 External Antenna Connections ....................................................................................2-20 Typical Connection for the Power Fail Input ................................................................2-21 Connection for a Backup Supply..................................................................................2-22 SIM Card Profile.............................................................................................................3-3 g18 SIM Card Holder Location.......................................................................................3-3 GSM20 SIM Card Installation ........................................................................................3-4 Location of ESN number on the c18 radio .....................................................................3-6 iDEN270 SIM Card Installation ....................................................................................3-10 MP32 Login Screen .......................................................................................................4-1 MP32 Start-Up Screen...................................................................................................4-2 Communication Port Configuration Screen....................................................................4-3 Main Configuration Screen ............................................................................................4-4 Screen Image with “Serial Port 1” Tab Selected............................................................4-8 Screen Image with the “Cellular Settings” Tab Selected..............................................4-10 Programming Cables ...................................................................................................4-12 Starting the System Configuration .................................................................................5-1 Changing the Data Collection Configuration..................................................................5-2 Configuring the IMU Server ...........................................................................................5-3 Configuring the DC-2009 for CSD Connections ............................................................5-4 Configuring a Call Schedule ..........................................................................................5-5 Defining a Call Profile Name..........................................................................................5-6 Defining the Call Profile Parameters ..............................................................................5-7 Starting the CNI Configuration Process .........................................................................5-8

Page 12: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.comxii

xii

Remote Unit Selection Screen.......................................................................................5-9 Device Type Selection Screen.......................................................................................5-9 Adding a New Unit .......................................................................................................5-10 Configuration Setup Screen.........................................................................................5-11 Data Input Configuration Screen..................................................................................5-12 Call Profile Screen .......................................................................................................5-13 Hardware Alarm Configuration Screen ........................................................................5-16 CNI’s LED Indicators......................................................................................................6-3 Battery-Powered Unit Assembly ....................................................................................7-1 Enclosure Dimensions ...................................................................................................7-3 Electrical Wiring Diagram...............................................................................................7-4 1001-0308-002 Power Supply Board.............................................................................7-5 1001-0316-002 Power Supply Board.............................................................................7-5 Installation of the lead acid battery ................................................................................7-7 AC-Powered (“Configuration-1”) Unit Assembly ............................................................8-1 Mounting Tab Locations.................................................................................................8-2 Enclosure Dimensions ...................................................................................................8-3 Enclosure Mounting Tab (1 of 4)....................................................................................8-3 Metal Safety Shield ........................................................................................................8-4 Routing and Connection of AC Mains Power.................................................................8-5 Installation of the Backup Batteries................................................................................8-6 Electrical Wiring Diagram...............................................................................................8-8 AC Power Supply Board ................................................................................................8-9 Block Diagram of the Power Supply Board..................................................................8-11 Cable Routing to the CNI .............................................................................................8-12 AC-Powered (“Configuration-2”) Unit Assembly ............................................................9-1 Enclosure Dimensions ...................................................................................................9-2 Electrical Wiring Diagram...............................................................................................9-3 1001-0308-001 Charger Board ......................................................................................9-4 1001-0316-001 Charger Board ......................................................................................9-4 12VAC Transformer .......................................................................................................9-6 Installation of the rechargeable battery..........................................................................9-6 Solar Powered Unit Assembly .....................................................................................10-1 Unit Assembly Dimensions ..........................................................................................10-2 Electrical Wiring Diagram.............................................................................................10-3 Solar Power Supply Board...........................................................................................10-3 Latitude Map for North America ...................................................................................10-5 Combination Square with Protractor Head ..................................................................10-6 Solar Panel Tilt Adjustment..........................................................................................10-6 Routing the Solar Panel Cable to the Power Supply Board.........................................10-8 Routing the External Device Cables to the CNI Board ................................................10-9 Flat Pack Interior View .................................................................................................11-1 Flat Pack Enclosure External Dimensions ...................................................................11-2 Flat Pack Enclosure Mounting Hole Locations and Sizes............................................11-3 Flat Pack Enclosure Assembly ....................................................................................11-4 Electrical Wiring Diagram.............................................................................................11-5 Location of the Magnetic CALL Switch ........................................................................11-6

Page 13: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

1-1

1-1

1 PRODUCT DESCRIPTION 1.1 Product Overview

Many metering devices generate electrical pulses to indicate a unit of measure. For example a gasoline pump might contain a rotating device whose speed of rotation is directly related to the amount of fluid flowing past it. With each rotation an electrical pulse is generated to indicate that a certain amount of gas has been dispensed. For these pulses to be meaningful there must be a way to count and save them for later use. Mercury’s CNI, configured with Industrial Metering Unit (IMU) software, is designed to count pulses over a period time and save the total as one record. It then repeats the process for the next time period and can do this for hours, days or months at a time. It can process pulses from two independent sources. It can also monitor several other electrical signals that might indicate alarm conditions, such as a low-pressure situation on a gas pipeline. In these situations the CNI can contact the central computer system immediately. At some point the CNI must transmit its records to a central computer system for processing and to make room for more storage. Traditionally data logging devices have used wired telephone lines and modems to communicate with the central computer system. But in some cases the device may have to be located in a very remote location and the cost of running phone lines to those locations may be quite high. In some hazardous locations phone lines may not be allowed. In general the monthly cost of wired phone service has greatly increased. The CNI was specifically designed to address these problems. Operating as a wireless modem, a connection is made using commercial digital cellular GSM, CDMA or iDEN phone networks. All models support either circuit-switched data (CSD) or Internet (packet) communications if these services are offered by the cellular service providers. The model GSM18 supports 900 / 1800 / 1900 MHz GSM service. Effective December, 2005 production of the GSM18 model was discontinued. However it remains fully documented in this manual for existing owners. The GSM20 supports 850, 900, 1800 and 1900 MHz, which are the four primary bands used around the world. The GSM20 replaces the earlier GSM18. The CDMA18 supports 850 & 1900 MHz CDMA service. CDMA is primarily used in North America. The iDEN270 supports the iDEN radio network on the 800 and 900 MHz bands. iDEN is primarily used in North America.

The Cellular Network Interface is simply referred to as the “CNI” throughout this document. This unit’s operating software allows it to behave as a legacy

data collection device known as an Industrial Metering Unit, or “IMU”.

Page 14: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com1-2

1-2

In addition to counting pulses and monitoring alarm signals nearly any device that has a serial RS-232 port can be connected to the CNI. A minimum of three wires is needed to carry data between the two units. Baud rates from 300 to 9600 are supported. In a special mode (CSD only) the CNI allows the central computer system to communicate directly with the serial device as though they were directly wired together. Mercury offers a powerful application program called DC-2009 that can collect information from thousands of devices, store their data in a database and present the results to user in a variety of formats. It can also notify the customer immediately when an alarm condition occurs. 1.2 DC-2009 Data Collection System Mercury offers a powerful data collection system called “DC-2009” that can collect information from thousands of devices, store their data in a database and present the results in a variety of formats. It can also notify you immediately when an alarm condition occurs. DC-2009 supports both CSD (circuit-switched data) and packet (Internet) connections. CSD mode requires the use of a special Mercury modem chassis called a MODSMOD (modular smart modem). This chassis can hold up to 8 modem cards. The MODSMOD uses a special communications protocol only recognized by Mercury products. It will reject any calls that do not follow this format. The 8 channels can hold a combination of 1200, 2400 and 9600 bps cards. A 9600 bps card is usually required for cellular communications whereas the slower cards support the legacy wire line communication devices. 1.3 CSD versus Packet (Internet) Mode The CNI can communicate with the central computer’s modem using a circuit-switched data (CSD) connection or it can exchange information with the central computer over the Internet using “packet” mode. There are advantages and limitations to each method. 1.3.1 CSD Mode CSD mode is similar to two modems communicating over a wired telephone line. This is very similar to a “dial up” connection between your home computer and your Internet Service Provider. The cellular service provider has banks of analog modems available in their switching centers. When it detects a CSD call it connects one of its own modems to the wired line and dials the central computer’s modem. Data is transferred between the CNI and the switching center over the radio link, and then between the switching center and the destination modem via wire. Cellular service providers often offer this service as an add-on package to a standard “voice” account, and each call is measured and billed in terms of minutes used. Depending upon the frequency and length of the calls this service can become quite expensive. In situations in which the calls are long distance it may be possible to purchase plans that include free long distance in order to reduce costs.

Page 15: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

1-3 1-3

Some cellular service providers may not support “mobile-terminate” connections, which means the CNI can place a call to the computer but cannot be called by the computer. However the central computer can “page” the CNI by dialing its voice number or by sending it a text message. This will cause the CNI to immediately call back to the central computer. Paging or dial-outs are not recommended for battery-operated units because the radio must remain powered up at all times and will quickly drain the battery. CSD mode requires the use of a special Mercury modem chassis called a MODSMOD (modular smart modem). See Section 1.2 about this.

Figure 1-1

Data Logger System using CSD

Page 16: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com1-4 1-4

1.3.2 Packet (Internet) Mode Cellular service providers may offer access to the Internet using a service generally called “packet service”. On GSM networks this is called the “general packet radio standard” (GPRS). On CDMA networks this is called “single carrier, radio transmission technology” (1X or 1XRTT). Data is exchanged in small blocks, or packets, with DC-2009. Cellular service providers may offer this service as an add-on package to a standard “voice” account, or may offer it as a stand-alone product. Each connection is usually measured and billed in terms of the amount of data exchanged each month. The amount of information exchanged on each call may range from several hundred bytes to 10’s of thousands of bytes, depending upon the information that is requested from the CNI. It may be necessary to test the system for several months and then adjust the cellular account for the best cost based on your needs. For instance if you purchase one million bytes (1 Mb) per month but only use 100,000, you may be able to purchase a smaller and thus less expensive plan. For security reasons the CNI cannot be contacted via the Internet because it only acts as a “client”. It is not listening for connection requests from other devices. Only an Internet “server” does that. However the central computer can “page” the CNI by dialing its voice number or by sending it a text message. This will cause the CNI to immediately call back to the central computer. Paging is not recommended for battery-operated units because the radio must remain powered up at all times and will quickly drain the battery. DC-2009 acts as an Internet server on your computer and thus must be allowed access to the outside world. Most corporate computer systems use firewall technology to prevent unauthorized and potentially damaging access from outside sources. To minimize potential invasion, DC-2009 and the CNI exchange private information using the 64-bit data encryption standard. If this exchange fails, the connection is immediately terminated. An Internet address and port number must be assigned to the computer running DC-2009, and these numbers must be programmed into each CNI. Your computer system’s administrator usually assigns the address and port number. When the CNI calls in it assigns itself what is known as a “source port” number. To further enhance security the CNI can be assigned only one or a specific range of source port numbers and the firewall can be programmed to only allow these through.

Page 17: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

1-5 1-5

Figure 1-2

Data Logger System using the Internet

1.4 Communications Scenarios Scenario #1: The CNI initiates a call to the central computer

• The CNI determines that a call should be made due to an alarm condition or a regularly scheduled call event.

• The cellular radio on the CNI establishes a connection with the cellular phone

network.

• The CNI initiates an outbound data call (CSD mode) or Internet connection (packet mode) to the central computer, which is running Mercury’s DC-2009 data collection software.

• The central computer processes the CNI’s data and stores it in a database

structure format.

Page 18: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com1-6 1-6

Scenario #2: The data collection computer initiates a CSD data call to the CNI:

• The CNI’s cellular radio is registered with the cellular network, and is therefore always ‘listening’ for an incoming call.

• The central computer dials the radio’s “data” number. This is known as a

“mobile-terminate” CSD connection. When the radio answers the call, it will establish a link with the computer’s modem, which is running Mercury’s DC-2009 data collection software.

• The computer processes the meter’s data and stores it in a database structure

format. Scenario #3: The data collection computer “pages” the CNI and waits for the CNI to call back.

NOTE: It is not possible to contact the CNI via the Internet because it only acts as a “client”. It is not listening for connection requests from other devices In CSD mode the cellular service provider may not support “mobile-terminate” connections, which allows a device to call the CNI. In these cases the CNI can be “paged”, which will cause the unit to call back immediately.

• The CNI cellular radio is registered with the cellular network, and is therefore

always ‘listening’ for an incoming call or message.

• If the cellular account has been assigned a voice or data phone number, the computer calls that number. The CNI answers the call, hangs up, and will immediately call back as described in Scenario #1.

• If the cellular account includes a feature called SMS (short message service), the

computer can send a text message to the CNI. When the CNI receives the message it will immediately call back as described in Scenario #1.

Page 19: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

2-1

2-1

2 INSTALLATION AND TECHNICAL INFORMATION 2.1 Unpacking, Damage reports, Item List Upon receipt, inspect the CNI for any potential shipping damage. If any damage is detected that can be attributed to the way the package was handled, then a claim should be filed with the shipping agent as quickly as possible. A typical CNI is provided with the following items:

• The Model GSM18, GSM20, CDMA18 or iDEN270 Cellular Network Interface card with Motorola g18, g20, g24, c18 or iO270 cellular radio module

• “IMU-DC” firmware • Antenna • Enclosure • Power source • Manual 900349 (this document). Normally only one manual is included with each

shipment rather than with each unit. Additional manuals can be ordered separately or obtained in PDF file format upon request.

Note: The items listed above may vary depending on what was requested with the original purchase order. Refer to the shipping document or the purchase order for a precise record when inspecting the package contents. 2.2 Additional Items Required for Installation Several additional tools and items will be required before proceeding with the field site installation. These are:

• Programming adaptor cable (RS-232) as illustrated in Chapter-4. This item can be ordered under Mercury part number 1002-0209B-001.

--- or --- Programming adaptor cable (USB) as illustrated in Chapter-4. This item can be ordered under Mercury part number 1002-0344-001.

• “MP32” configuration software, available under part number 100160, version

4.1.1 or later. • Computer system with a Windows-98 or newer operating system. A laptop

computer is usually recommended for reasons of portability in the field. We are required to say that “Windows” is a registered trademark of Microsoft, Inc.

• An activated SIM card to enable the GSM or iDen cellular radio module. This

must be obtained from the cellular service provider. CDMA radios do not require a SIM card and the radios usually need to be programmed for the specific carrier prior to shipment. See Chapter-3 for more information.

• Voltmeter for installation and basic troubleshooting.

• Hand tools, fasteners, mounting hardware, cable wiring, etc

Page 20: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com2-2

2-2

2.3 Site Selection for Best Performance

WARNING No hazardous area safety approvals have been

issued for this product. It is therefore necessary to ensure that the product is only installed at locations that are classified as ‘safe area’ sites.

See Chapter-12 for more safety information.

Field site selection for a cellular communications product requires additional consideration with regard to antenna placement.

• Ensure that the antenna is pointing in a vertical direction. • Mount the unit away from buildings and structures when possible. Buildings tend

to block the RF signal if they lie in the path between the cellular tower and the CNI. Outdoor installations are preferred

• Raise the elevation as high as practical from the ground.

• Avoid mounting the unit to the side of a metal shed or similar structure since

metal is a very effective shield against the desired RF signal. Chain link fences are normally not a problem.

• Avoid mounting the product in a location where the antenna is in close proximity

to a measurement instrument such as a Rosemont transducer. The strong R.F. field from the cellular module transmitter could possibly degrade the accuracy of these precision instruments. Conversely, nearby electronic equipment may interfere with the operation of the cellular radio.

Depending on the signal strength for a given location, it may be possible to violate some of these suggestions and still obtain good performance. This will vary from one site to the next, just as the reception quality of a handheld cellular phone will vary. The CNI is provided with several antenna options. If the antenna provided does not provide adequate performance, a different antenna can be used as long as it complies with the impedance and frequency range of the cellular radio module. For instance, the CNI may be located in a metal building but a mobile antenna, such as the type that would mount to the roof of a vehicle, may be located outside of the building.

Page 21: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

2-3

2-3

This product contains a radio-frequency transmitter, Motorola Model g18, FCC ID # IHDT6AC1,

Motorola Model g20, FCC ID # IHDT56DB1, Motorola Model g24, FCC ID # IHDT56FV2

Motorola Model c18, FCC ID # IHDT56CW1 or Motorola Model iO270, FCC ID # AZ489FT7011

The combined cable loss and antenna gain must not exceed +6.8 dBi (850

band), +1.9 dBi (900 band), +7.7 dBi (1800 band) and +2.2 dBi (1900 band). Total system output must not exceed 2.0W EIRP in the 1900 band in order to comply with the EIRP limit of 24.232. The antenna installation must provide a minimum separation distance of 20cm (8”) from users and nearby persons and

must not be collocated or operating in conjunction with any other antenna or transmitter.

See Chapter-12 for more safety information.

Page 22: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com2-4 2-4

2.4 CNI Board Revisions Rev-A, B or C versions of the CNI board look like this:

Figure 2-1

CNI Board Revisions A, B or C JUMPER POSITION NOTES

J2 - Shorting this input will force the unit to call in JP3 A-B For applications that require the DSR control line to have RS-

232 voltage levels (± 9V) JP3 B-C For applications that require the DSR control line to have +5V

and 0V voltage levels. JP4 - Momentary short will reset unit and clear data memory JP7 - Used for factory testing only.

Table 2-1

CNI Rev A, B and C Jumper Configurations

Page 23: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

2-5

2-5

Rev-D, E or later versions of the CNI board look like this:

Figure 2-2

CNI Board Revisions D and E.

Page 24: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com2-6 2-6

JUMPER POSITION NOTES

J2 - Shorting this input will force the unit to call in JP1-A A-B For applications that require the receive data (RXD) input line

to have RS-232 voltage levels (± 9V). JP1-C must also be set to the A-B position.

JP1-A B-C For applications that require the receive data (RXD) input line to have +5V and 0V voltage levels. JP1-C must also be set to the B-C position.

JP1-B A-B For applications that require the transmit data (TXD) output line to have RS-232 voltage levels (± 9V)

JP1-B B-C For applications that require the transmit data (TXD) output line to have +5V and 0V voltage levels.

JP1-C A-B For applications that require the receive data (RXD) input line to have RS-232 voltage levels (± 9V). JP1-A must also be set to the A-B position.

JP1-C B-C For applications that require the receive data(RXD) input line to have +5V and 0V voltage levels. JP1-A must also be set to the B-C position.

JP1-D A-B For applications that require the DCD output line to have RS-232 voltage levels (± 9V)

JP1-D B-C For applications that require the DCD output line to have +5V and 0V voltage levels.

JP1-E A-B For applications that require the DSR output line to have RS-232 voltage levels (± 9V)

JP1-E B-C For applications that require the DSR output line to have +5V and 0V voltage levels.

JP4 - Momentary short will reset unit and clear data memory JP7 - Used for factory testing only.

Table 2-2

CNI Rev-D and E Jumper Configurations

Page 25: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

2-7

2-7

2.5 Model GSM18 Layout The Model GSM18 circuit board assembly is shown in Figure 2-3. The GSM18 was discontinued in December, 2005. However it remains fully documented here for existing owners.

Figure 2-3

Primary Components of the Model GSM18

Page 26: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com2-8 2-8

2.6 Model GSM20 Layout The Model GSM20 circuit board assembly is shown in Figure 2-4.

Figure 2-4

Primary Components of the Model GSM20

Page 27: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

2-9 2-9

2.7 Model CDMA18 Layout The Model CDMA18 circuit board assembly is shown in Figure 2-5.

Figure 2-5

Primary Components of the Model CDMA18

Page 28: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com2-10 2-10

2.8 Model iDEN270 Layout The Model iDEN270 circuit board assembly is shown in Figure 2-6.

Figure 2-6

Primary Components of the Model iDEN270

Page 29: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

2-11

2-11

2.9 CNI Block Diagram

Figure 2-7

Block Diagram of the CNI

Page 30: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com2-12 2-12

2.10 Circuit Board Dimensions and Mounting Hole Pattern For outdoor applications the CNI should be mounted inside a weatherproof enclosure. Critical components and connections are conformal coated to resist humidity, but direct contact with water or any other liquid must be avoided. Protection against insects and rodents is also required.

Figure 2-8 CNI Physical Dimensions

IMPORTANT NOTE

The lower right-hand mounting hole is located directly under the radio or the SIM card holder. A standoff or fastener that protrudes through this hole will damage

the assembly.

Page 31: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

2-13 2-13

2.11 Power Supply Requirements The CNI can be powered from one single filtered dc power supply in the range of 9 to 28 volts dc at 800 milliamps minimum. Most current is drawn by the cellular radio. For the GSM18 and GSM20 the average current is 300 milliamps, but peak currents can be as high as 1.8 amps for a duration of 0.5 milliseconds every 4.5 milliseconds. For the CDMA18 the continuous current during communications is about 800 mA. For the iDEN270 the average current is 250 milliamps, but peak currents can be as high as 1.2 amps for a duration of 15 milliseconds every 90 milliseconds. The power connection is made at the TB2 terminal block. Be certain to observe proper polarity when connecting the power source. Connect the positive (+) side to the “Vbat” input and the negative (-) input to “GND”. The input is reverse-polarity protected. The CNI can be programmed to enter a low-power sleep mode when the radio is not being used. However the device will continue to draw several milliamps from TB2. This may not be desirable in battery-powered applications. Provisions have been made to allow a low-current, 4.5V - 5.5V dc standby supply to be connected to J3. This supply should be able to source 50 mA minimum. With the TB2 power supply turned off the CNI will draw less than 800 micro amps from J3. A control signal is available at connector J6, Pin-3 that can be used to turn off the TB2 supply. This signal goes high (>3V) when the high-current supply is needed. See Figure 2-16 for a typical wiring arrangement.

For Rev-A, B or C boards never connect a battery directly to the J3 connector when power is present on the TB2 terminal

block. The battery may explode, resulting in injury and

damage to property. If a battery is used it must be protected with a blocking diode

in series with the battery.

See Section 2.17 for more information.

Rev-D and E boards do not require a blocking diode.

Page 32: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com2-14

2-14

2.12 Wiring External Devices to the CNI’s Communications Port The external device must have an RS-232 serial port. A minimum of three lines is required for the simplest connection: a line to transmit data to the CNI, one to receive data from the CNI, and common. The CNI does not support hardware handshaking.

Figure 2-9 Minimum Connection of an External Device to the CNI

Page 33: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

2-15 2-15

2.13 Installing the Optional Dual-Port Multiplexer The optional dual-port multiplexer board (Mercury Stock # 1001-0314-001) allows two external serial devices to connect to one CNI.

Figure 2-10

Dual Port Multiplexer Board Figure 2-11 depicts the multiplexer board installed directly on the CNI. The pins of the multiplexer board are inserted into the CNI’s terminal block. All screws on the CNI’s terminal block must be tightened to ensure proper electrical contact. Connections are then made to the multiplexer board’s terminal block for all alarm inputs as well as the serial communications connections to the two devices.

Page 34: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com2-16

2-16

Figure 2-11 Installed Dual Port Multiplexer Board

If the direct mounting arrangement is not practical then the multiplexer board can be mounted in another location using the two mounting holes on either end of the board. The “J3” connector is used to connect the six interface lines to the terminal block on the CNI. The “J3” connector is a 6-pin “MTA” style male connector on 0.1” (2.54 mm) centers. The connector has a built-in polarity tab to prevent the mating connector from being installed incorrectly. A suggested mate is an AMP 641190-6. Do not exceed a cable length greater than 10’ (3.3 m). See Figure 2-11 for the proper wiring. Mercury offers a pre-assembled 4” (100 mm) cable assembly that can be used to make this connection. Order stock number 1002-0327-001.

Page 35: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

2-17 2-17

When using the “J3” connection, the alarm and status inputs are not connected to the CNI board. Therefore you must connect these inputs directly to the CNI’s terminal block.

Figure 2-12

Externally-Mounted Dual Port Multiplexer Board The CNI must be informed that the dual-port multiplexer is installed. See Chapter-4 about this. See Chapter-6 for additional information about using the multiplexer board in CSD mode. Figure 2-13 depicts a typical wiring diagram for two serial devices.

Page 36: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com2-18

2-18

Figure 2-13

Typical Wiring of Two Serial Devices to the Multiplexer Board

Page 37: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

2-19 2-19

2.14 Using the CNI’s Alarm Inputs The CNI has provisions to accept up to five input signals that can be used to generate alarm conditions and place immediate calls if desired (the CNI must be configured to originate calls to the central computer for these alarms to be reported immediately). Leave any of these connections open if not needed. See Chapters-4 and 6 for more information about alarms. Alarm Inputs #1 and #2 accept Form-A (normally open) contacts. The CNI can be programmed to place an immediate call when either input closes. If an immediate call is not allowed, the alarm condition(s) will be reported on the next call to the central computer. If the CNI has been configured to collect pulse information from these inputs then they cannot be used for alarm monitoring. You can however use one input for pulse counting and the other for alarm monitoring. In this case Alarm Input #1 must be used for pulse counting. The General Alarm input is wired in parallel with the “CALL” jumper J2. Momentarily closing this connection will cause the unit to place an immediate call to the central computer. Another input called TAMPER accepts a Form-B (normally closed) contact that, when opened, will place an immediate call to the central computer. In some unit assemblies this input will be connected to a magnetic reed switch that opens when the enclosure’s door is opened. The fifth input, referred to as the POWER FAIL input, is generally used to sense and report a failure of the primary power supply when a backup power source exists. This input must remain active for longer than 5 minutes before a call will be placed. The CNI will report an “AC-OFF” alarm to the DC-2009 data collection system. Once the call is placed the CNI will go into a low-power sleep mode, which will be discussed in more detail in Chapter-6. When the input again goes inactive it must remain inactive for longer than 5 minutes before another call will be placed. The CNI will report an “AC-ON” alarm to the DC-2009 data collection system. Once this condition is reported the CNI will return to full operation. The hardware connection to this input is discussed later in this chapter.

WARNING All alarm inputs must be contact closures only, such as mechanical switches or

open-collector transistor outputs. Do not connect devices that produce voltages such as amplifiers or damage may result.

Page 38: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com2-20 2-20

2.15 External Antennas The CNI can be supplied with several types of internal antennas. These are preferable as they are not as prone to vandalism or damage from the forces of nature. But if the CNI is to be mounted in or against a metal enclosure that blocks most radio signals it may be necessary to use an external antenna. There are a number of external antenna kits available and these are listed in the Specifications chapter. Most of the cables terminate with an industry-standard rf connector called a female “SMA”. Contact Mercury for other termination options. Each model of the CNI uses a different radio. Most use the same type of “MMCX” antenna connector but they are located in different positions. Figure 2-14 illustrates this difference. Please note that the c18 CDMA radio has two connectors. It is important to install the cable into the right-hand connector. The iO270 radio uses a smaller “U.FL” connector that requires a different type of mating connector. It also has two antenna connectors and the lower right-hand connector should be used.

Figure 2-14

External Antenna Connections

Page 39: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

2-21 2-21

2.16 Using the Power Fail Input The “Power Fail” input connector J6 is a 3-pin “MTA” style male connector on 0.1” (2.54 mm) centers. The connector has a built-in polarity tab to prevent the mating connector from being installed incorrectly. A suggested mate is an AMP 641190-3. Figure 2-15 shows a typical wiring arrangement for this connector. The “Power Fail” input can be used in systems that are normally powered from an ac power source and have a backup battery source in the event ac power fails. A power failure should not interrupt the power to the CNI otherwise it will cause the unit to reset and the CNI will lose any accumulated data. See Section 2.13 and Chapter-6 for more information about how the CNI responds to this input.

Figure 2-15

Typical Connection for the Power Fail Input 2.17 Supplying Backup Power to the CNI The CNI can be programmed to enter a low-power sleep mode when the radio is not being used. This mode allows the CNI to place outgoing calls only. It will not be able to receive calls or pages because this would require the radio to be powered up at all times. The radio consumes the most current in the system. Even when the CNI is in sleep mode it will continue to draw several milliamps from TB2. This may not be desirable in battery-powered applications. Provisions have been made to allow a low current, 4.5V to 5.5V dc standby supply to be connected to J3. This supply should be able to source 50 mA minimum. With the TB2 power supply turned off the CNI will draw less than 800 micro amps from J3.

Page 40: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com2-22

2-22

A control signal is available at connector J6, Pin-3 that can be used to turn off the TB2 supply. This signal goes high (>3V) when the high-current supply is needed. See Figure 2-16.

Figure 2-16 Connection for a Backup Supply

For Rev-A, B or C boards never connect a battery directly to the J3 connector when power is present on the TB2 terminal

block. The battery may explode, resulting in injury and

damage to property.

If a battery is used it must be protected with a blocking diode in series with the battery.

Rev-D and E boards do not require a blocking diode.

Page 41: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

2-23 2-23

2.18 Quick Power-Up Check Connect the external power supply to TB2. The green “PROGRAM MONITOR” light should light solidly. The red “RECEIVE DATA” light should light momentarily, then go out. The green “PROGRAM MONITOR” light should then start flashing once per second. This indicates the CNI is running. Turn off power for now until it is time to configure the board (see Chapter-4).

Page 42: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com2-24

Page 43: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

3-1

3-1

3 CELLULAR SERVICE 3.1 GSM Service 3.1.1 GSM Overview GSM is an abbreviation for Global System for Mobile communications. This communications standard is widely used throughout Europe, Africa, Asia and parts of North and South America. Messages are digitized into packets and sent in brief bursts during allocated time slots using a variation of TDMA (Time Division Multiple Access) techniques. Up to 8 cellular phones can thus share the same frequency band, which in turn permits the system to support more users with existing equipment. Efficient utilization of spectrum is an important consideration for service providers since there is only a limited bandwidth space that has been allocated to cellular phone service. Most GSM systems throughout the world operate on either the 900 MHz or 1800 MHz communications bands. In North America most GSM systems operate on the 1900 MHz band. Also, many older 850 MHz analog networks in North America are being converted for GSM service. One version of the GSM20 covers both the 850 and 1900 MHz bands. Another covers the 900 and 1800 MHz bands. 3.1.2 Establishing Cellular Service for GSM GPRS Packet Service A cellular account must be activated with a cellular service provider prior to placing a CNI into service. Some GSM service providers may not offer all forms of data transfer. General packet radio service (GPRS) may have to be added to a standard voice plan, or may be a stand-alone service. GPRS packages are generally priced by the number of bytes to be transferred rather than by the minute. Typically the smallest available package will be 1 megabyte (1 Mb) per month. The amount of data that the CNI will produce depends upon what sort of data is requested from the remote device. The amount of information exchanged on each call may range from several hundred bytes to 10’s of thousands of bytes. It may be necessary to test the system for several months and then adjust the cellular account for the best cost based on your needs. In order to connect to the Internet, the cellular service provider has its own computer equipment called a “gateway” server, aptly named, as it is their gateway to the Internet. The server will have an “APN” (access point name), usually in the form of a domain name such as “internetaccess.providername.com” or something as simply as “proxy”. Contact your service provider for this information. This APN will be needed when configuring the CNI (Chapter-4). Service providers may have several different gateways to choose from, depending upon the type of service required. “Web phones” (cellular phones that support Internet access) are generally assigned to a gateway that only connects to WAP services (wireless application protocol). The CNI requires full Internet access because the data collection software could be running on any server located anywhere in the world. Full access gateways are usually assigned to customers who will be connecting a cellular modem to a personal computer.

Page 44: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com3-2

3-2

Another parameter that will be needed is the packet service connection command. In most cases the command will be ATD*99# but you may want to check with your service provider. Finally, the service provider may ask the device type, which must be specified as either the “CNI / GSM18” or “CNI / GSM20”. 3.1.3 Establishing Cellular Service for GSM CSD A cellular account must be activated with the local service provider prior to placing a CNI into service. Many GSM service providers offer some sort of data support, but their marketing focus may be on Internet connectivity or short-message services (“SMS”, used to send text messages to and from cellular phones). This does not necessarily mean that they support all forms of data transfers. The service provider must support asynchronous circuit-switched data (CSD) exchange at 4800 or 9600 baud. The baud rate must match the baud rate of the central computer’s modem. Sometimes this capability may be included as part of a standard voice package or it may be an add-on feature at extra cost. One consideration when ordering service is the frequency of calls to and from the CNI. Each service provider offers different packages that may include a fixed number of minutes per month for a fixed price. However, when this number is exceeded, the cost per each additional minute can be very high. There are also variations in the way “minutes” are measured. For example, a call lasting 1 minute 10 seconds may be considered to be a 2-minute call by some providers. It might be possible to purchase less expensive packages that have additional “weekend” or “evening” minutes, and then schedule the remote device to call in at those times. Some plans may offer the 1st minute free. This might be advantageous for short calls. Another consideration when ordering service is the location of the CNI with respect to the service provider’s network. It is best to describe where the units will be located and where they will be calling, otherwise you could be charged “roaming” or long-distance fees. Some providers offer free long distance or no roaming charges as part of their basic plans. The final consideration is the direction of the calls. If the CNI is to originate calls, then the service must support “mobile-originate” service. If the unit is to receive calls, then “mobile-terminate” service is required. The service provider will need the following information:

• Type of cellular service desired, which is circuit-switched data (CSD). • The device type, which must be specified as the “CNI / GSM18” or “CNI /

GSM20” • Data mode is to support 4800 or 9600-baud operation. This rate must match the

speed of central computer’s modem. • Mobile-originate and/or mobile-terminate service. • Number of minutes per month. • Location of the CNI and the location of central computer (to determine if

“roaming” or long distance charges apply).

Page 45: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

3-3

3-3

• The service provider may need to know the “IMEI” number printed on the radio. 3.1.4 SIM Card Installation for the GSM18 After the account has been established, the cellular service provider will provide a small memory card known as a SIM card (Subscriber Identity Module). Figure 3-1 illustrates the appearance of a SIM card.

Figure 3-1

SIM Card Profile For the GSM18 the cellular module has a built-in SIM card holder. Care must be exercised to ensure that the electrical contacts of the SIM card will mate properly with the electrical contacts on the radio module. Figure 3-2 illustrates the location of the holder. Note the location of the notched corner on the SIM card.

Figure 3-2 g18 SIM Card Holder Location

Page 46: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com3-4

3-4

Never install a SIM card when power is present.

Follow these steps for SIM card installation:

1) Remove the connectors at J2 and J3 of the power supply board.

2) Install the SIM card as shown in Figure 3-2. Be sure to observe the location of the notch on one corner of the SIM card.

3.1.5 SIM Card Installation for the GSM20 The SIM card holder for the GSM20 is located on the top side of the CNI board. The board does not have to be removed to install the card. See Figure 3-3.

Never install a SIM card when power is present.

Figure 3-3

GSM20 SIM Card Installation

Page 47: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

3-5

3-5

3.1.6 Requesting a Voice Phone Number or SMS Service As mentioned earlier some cellular service providers may not support the ability to place a data call to the CNI in CSD mode. This is called “mobile-terminate” service. If purchasing packet service it is important to know that the CNI cannot be contacted via the Internet because it only acts as a client and is not listening for connection requests from other devices. Only an Internet server does that. Yet there may be times when it is desirable to communicate immediately with the remote device rather than wait for it to call in. The CNI supports the ability to be “paged”. When paged the CNI will immediately call back to the central computer. There are two ways to page, and these are described in Chapter-6. If the cellular account has been assigned a “voice” or “data” number then the unit can be called using this number. Otherwise most cellular providers can include SMS (short message service) as part of the package. This allows the CNI to be paged with a text message. The SMS address of the unit is often created using the voice or data phone number as part of the address, such as [email protected]. 3.2 CDMA Service 3.2.1 CDMA Overview CDMA is an abbreviation for Code Division Multiple Access communications. CDMA technology was originally developed for military applications but was eventually commercialized. This communications standard is widely used in North America and in some parts of Asia and South America. Rather than dividing calls into time slots like GSM, CDMA allows all users to transmit at the same time. Each call is accompanied by a unique digital code that allows it to be differentiated from the rest. As an analogy suppose you are in a crowded room and many conversations are taking place at the same time. Your brain is able to distinguish the conversation you are having with your friend because it is able to focus on your friend’s voice characteristics. As the room grows more crowded each person must talk louder and the size of the conversation “zone” grows smaller. You may have to move closer to your friend to keep the conversation going. Thus the number of conversations is limited by the overall interference and noise in the room. 3.2.2 Establishing Cellular Service for CDMA 1XRTT Packet Service A cellular account must be activated with a cellular service provider prior to placing a CNI into service. Some CDMA service providers may not offer all forms of data transfer. Single carrier, radio transmission technology (1X or 1XRTT) packet service may have to be added to a standard voice plan, or may be a stand-alone service. Packet service packages are generally priced by the number of bytes to be transferred rather than by the minute. Typically the smallest available package will be 1 megabyte (1 Mb) per month. The amount of data that the CNI will produce depends upon what

Page 48: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com3-6

3-6

sort of data is requested from the remote device. The amount of information exchanged on each call may range from several hundred bytes to 10’s of thousands of bytes. It may be necessary to test the system for several months and then adjust the cellular account for the best cost based on your needs. The CNI requires full Internet access because the data collection software could be running on any server located anywhere in the world. Full access is usually assigned to customers who will be connecting a cellular modem to a personal computer. One parameter that will be needed is the packet service connection command. In most cases the command will be ATD#777 but you may want to check with your service provider. The service provider may ask the device type, which must be specified as the “CNI / CDMA18”. The service provider will need to know the “ESN” number printed on the radio. This is printed on a label on the c18 radio as shown in Figure 3-4. Make sure this number is correct. It consists of 8 digits and can consist of both numeric and alpha characters. The printing is small and it is often difficult to distinguish between a zero (“0”) and an upper-case “D”.

Figure 3-4

Location of ESN number on the c18 radio 3.2.3 Establishing Cellular Service for CDMA CSD A cellular account must be activated with the local service provider prior to placing a CNI into service. Many CDMA service providers offer some sort of data support, but their marketing focus may be on Internet connectivity or short-message services (“SMS”, used to send text messages to and from cellular phones). This does not necessarily mean that they support all forms of data transfers. The service provider must support asynchronous circuit-switched data (CSD) exchange at the baud rate of the central computer’s modem. Sometimes this capability may be included as part of a standard voice package or it may be an add-on feature at extra cost. One consideration when ordering service is the frequency of calls to and from the CNI. Each service provider offers different packages that may include a fixed number of

Page 49: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

3-7

3-7

minutes per month for a fixed price. However, when this number is exceeded, the cost per each additional minute can be very high. There are also variations in the way “minutes” are measured. For example, a call lasting 1 minute 10 seconds may be considered to be a 2-minute call by some providers. It might be possible to purchase less expensive packages that have additional “weekend” or “evening” minutes, and then schedule the remote device to call in at those times. Some plans may offer the 1st minute free. This might be advantageous for short calls. Another consideration when ordering service is the location of the CNI with respect to the service provider’s network. It is best to describe where the units will be located and where they will be calling, otherwise you could be charged “roaming” or long-distance fees. Some providers offer free long distance or no roaming charges as part of their basic plans. The final consideration is the direction of the calls. If the CNI is to originate calls, then the service must support “mobile-originate” service. If the unit is to receive calls, then “mobile-terminate” service is required. The service provider will need the following information:

• Type of cellular service desired, which is circuit-switched data (CSD). • The device type, which must be specified as the “CNI / CDMA18”. • Data rate. This rate must match the speed of central computer’s modem. • Mobile-originate and/or mobile-terminate service. • Number of minutes per month. • Location of the CNI and the location of central computer (to determine if

“roaming” or long distance charges apply). • The service provider will need to know the “ESN” number printed on the radio.

This is printed on a label on the c18 radio as shown in Figure 3-4. 3.2.4 Requesting a Voice Phone Number or SMS Service As mentioned earlier some cellular service providers may not support the ability to place a data call to the CNI in CSD mode. This is called “mobile-terminate” service. If purchasing packet service it is important to know that the CNI cannot be contacted via the Internet because it only acts as a client and is not listening for connection requests from other devices. Only an Internet server does that. Yet there may be times when it is desirable to communicate immediately with the remote device rather than wait for it to call in. The CNI supports the ability to be “paged”. When paged the CNI will immediately call back to the central computer. There are two ways to page, and these are described in Chapter-6. If the cellular account has been assigned a “voice” or “data” number then the unit can be called using this number. Otherwise most cellular providers can include SMS (short message service) as part of the package. This allows the CNI to be paged with a text message. The SMS address of the unit is often created using the voice or data phone number as part of the address, such as [email protected].

Page 50: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com3-8

3-8

3.2.5 Over-the-Air Activation Unlike GSM, CDMA technology does not support the use of a SIM card (Subscriber Identity Module) to hold and transport account information. Therefore the account information must be downloaded into the cellular radio’s own memory. This is usually accomplished by dialing a special phone number to request “over-the-air-activation” (OTAA). The activation phone number is specific to the service provider and must be programmed into the CNI using the MP32 configuration software (Chapter-4). The OTAA process does two things. After the first successful OTAA call a new phone number is programmed into the phone. This is the number that can be used to page the unit via a phone or data call, or via an SMS message. It also starts the account billing process. Second, a “preferred roaming list” (PRL) is downloaded into the phone. This instructs the radio which service provider(s) to search for and connect to. Over-the-air activation is attempted whenever the unit is reset. Another call will be attempted if the first one fails. After two unsuccessful attempts the CNI will go into an idle mode and will attempt another OTAA call every hour until one is successful. Until then the unit will not be able to call in to the data collection system. After the first successful call an OTAA call is then performed every 7 days. The reason for this is that cellular service providers often make arrangements with other providers to carry calls in areas where their own equipment and towers do not exist. These agreements allow the call to be forwarded at no additional charge. The preferred roaming list says that it is acceptable to connect with these carriers. However at some point your service provider may install new equipment in these areas and the contract with the partner may be terminated. In this new situation roaming fees will be added to each call if the radio is allowed to connect to the other carriers. This is why it is important to periodically update the PRL. The OTAA call process is discussed in more detail in Chapter-6. 3.3 iDEN Service 3.3.1 iDEN Overview iDEN is an abbreviation for Integrated Digital Enhanced Network. This communications standard was developed by Motorola and provides its users the benefits of a trunked radio and a cellular telephone. Up to six communication channels share a 25 kHz space. iDEN operates on either the 800 MHz or 900MHz bands and is based on time division multiple access (TDMA) and GSM architectures. It supports circuit-switched data (CSD) and packet (Internet) communications, as well as voice and two-way radio services. 3.3.2 Establishing Cellular Service for iDEN Packet Service A cellular account must be activated with a cellular service provider prior to placing a CNI into service. Some iDEN service providers may not offer all forms of data transfer.

Page 51: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

3-9

3-9

Packet (Internet) service may have to be added to a standard voice plan, or may be a stand-alone service. Packet service is generally priced by the number of bytes to be transferred rather than by the minute. Typically the smallest available package will be 1 megabyte (1 Mb) per month. The amount of data that the CNI will produce depends upon what sort of data is requested from the remote device. The amount of information exchanged on each call may range from several hundred bytes to 10’s of thousands of bytes. It may be necessary to test the system for several months and then adjust the cellular account for the best cost based on your needs. 3.3.3 Establishing Cellular Service for iDEN CSD As of May 2006 there were no known iDEN providers that were supporting circuit-switched data (CSD) service in North America. Furthermore, the iDEN270 does not support incoming (“mobile-terminate”) CSD calls. Therefore the iDEN270 will treat all incoming calls as pages and will not attempt to make a CSD connection (see Chapter-6 about paging). If the iDEN270 is programmed to make a CSD call, the call will actually go out as a voice call. It will not attempt to make a CSD connection. The CNI would normally be programmed to use packet connections for most situations. However there is one alarm input that can be configured to place a voice call to a pager or another phone for the purpose of alerting someone of the situation. 3.3.4 SIM Card Installation for the iDEN270 The SIM card holder for the iDEN270 is located on the top side of the CNI board. The board does not have to be removed to install the card. See Figure 3-5.

Never install a SIM card when power is present.

Page 52: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com3-10

3-10

Figure 3-5

iDEN270 SIM Card Installation

Page 53: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

3-11 3-11

3.3.5 Requesting a Voice Phone Number or SMS Service The CNI cannot be contacted via the Internet because it only acts as a client and is not listening for connection requests from other devices. Only an Internet server does that. Yet there may be times when it is desirable to communicate immediately with the remote device rather than wait for it to call in. The CNI supports the ability to be “paged”. When paged the CNI will call back to the central computer. There are two ways to page, and these are described in Chapter-6. If the cellular account has been assigned a “voice” number then the unit can be called using this number. Otherwise most cellular providers can include SMS (short message service) as part of the package. This allows the CNI to be paged with a text message. The SMS address of the unit is often created using the voice phone number as part of the address, such as [email protected].

Page 54: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com3-12

Page 55: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

4-1

4-1

4 CONFIGURATION USING MERCURY PROGRAMMER (MP32) 4.1 Programmer Cable Before placing a CNI into service, it is necessary to setup certain configuration parameters. Setting up the configuration requires a computer, Mercury programmer (MP32) software and a special programming cable. These items are listed below:

• Programming adaptor cable (RS-232) as illustrated in Figure 4-7. This item can

be ordered under Mercury part number 1002-0209B-001. --- or ---

Programming adaptor cable (USB) as illustrated in Figure 4-7. This item can be ordered under Mercury part number 1002-0344-001.

• “MP32” configuration software, available under part number 100160, version

4.1.1 or later. • Computer system with a Windows-98 or newer operating system. A laptop

computer is usually recommended for reasons of portability in the field. We are required to say that “Windows” is a registered trademark of Microsoft, Inc.

The CNI stores configuration information in its non-volatile memory. This information is not lost when power is removed or the unit is reset. Certain parameters are unique to each CNI, such as a phone number to call, cellular service details, etc. These parameters can be programmed prior to, during, or after installation of the device in the field, although it is normally most convenient to setup and test the configuration prior to installation. 4.2 MP32 Software Startup MP32 can operate as a stand-alone program or can work in conjunction with Mercury’s DC-2009 data collection software. When MP32 is started it will require a user name and password. If DC-2009 is present then the password must match one of the passwords from DC-2009’s list of authorized users. If this is a standalone application then leave the password blank.

Figure 4-1 MP32 Login Screen

Page 56: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com4-2

Page 57: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

4-3 4-3

Figure 4-3 Communication Port Configuration Screen

Note about the USB Cable

When the USB cable is plugged in, the system will detect it and load software called a “driver”. When the installation is complete the system will assign a new COM port to the cable, such as COM5. It may not be apparent what COM number has been assigned. To find this out go to:

Settings Control Panel System Hardware Device Manager Ports

You should see your USB cable there and its assigned COM port. But it will not appear if the cable has been unplugged. Each USB cable has a unique electronic serial number. The system will remember this. If one USB cable is unplugged and another one is installed, the system will not reuse the previous COM port number. Rather it will assign a new COM port number to it. For instance if the previous cable was assigned COM5, the new cable might become COM6. In rare cases you may have to install the software driver for the USB cable depending upon the age of your computer and its operating system. This driver is available on Mercury’s website.

Page 58: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com4-4

Page 59: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

4-5

4-5

4.3.1 Remote Unit ID Each CNI must have a unique ID number. Legal six-digit values are 000000-FFFFFF (hexadecimal notation). Sequential numbering is not required, nor is it necessary to use any of the hexadecimal digits ‘A, B, C, D, E, or F’. 4.3.2 Destination If the CNI is allowed to originate a data call to another modem (CSD mode), then it will need the phone number of the modem. Select the “Phone Number” button and enter up to 32 numeric digits, including the “#” and “*” symbols. As with cellular phones, it is usually necessary to enter the entire phone number, including area code, even if the call is local. For example, in the U.S., a call to 555-1212 within area code 987 may have to be entered as 19875551212. If the CNI is to communicate via the Internet then it will need the IP address and port number of the data collection server. Your computer system’s administrator usually assigns these values. Select the “IP Address” button. Then enter the address of the server expressed in “dotted decimal format”, such as 198.32.67.101. The IMU data collection server is assigned a default port number of 50463. This value is displayed on the MP32 screen for reference only. This is the port number that will need to be assigned on the server. If the port number needs to be changed hold down the CTRL key on the keyboard, point to the port number box and double click the pointing device (ie – mouse). Then enter a new port number. 4.3.3 Originate Calls Check this box if the CNI is allowed to originate CSD calls or Internet connections. 4.3.4 Respond to Voice Calls Check this box if the CNI is allowed to answer CSD calls, or is allowed to be paged using its voice phone number. See Chapter-6 for more information about paging. 4.3.5 Respond to SMS Check this box if the CNI is allowed to be paged via SMS (short message service). See Chapter-6 for more information about paging. 4.3.6 Maintain Internet Connection When the CNI originates an Internet connection, it must request access to the cellular provider’s packet service, then access to the Internet and finally access to the destination server. All of this negotiation takes a certain amount of time. To reduce this

If this option is selected the radio will remain powered up at all times. This will greatly shorten battery life in battery-operated units, or may exceed the

ability for solar-powered units to maintain a charge on the battery. It may be necessary to use a constant dc power source.

If this option is selected the radio will remain powered up at all times. This will greatly shorten battery life in battery-operated units, or may exceed the

ability for solar-powered units to maintain a charge on the battery. It may be necessary to use a constant dc power source.

Page 60: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com4-6

4-6

time the CNI can maintain access to the Internet at all times and only needs to request access to the destination server, which only takes a few seconds. This is often referred to as an “always on” connection. NOTE: To use this feature you must also check the Originate Calls checkbox. When maintaining an Internet connection it is not possible to answer incoming phone calls or SMS pages, so those selection boxes are disabled on the screen. 4.3.7 Dual Port This selection allows two external RS-232 devices to be connected to the CNI using the optional dual-port multiplexer board described in Chapter-2. If the Dual Port box is checked then two other selections are enabled. The first selection is only used in CSD mode and allows the CNI to wait a certain number of seconds to receive a “port select” command from the central computer, which will be discussed in Chapter-6. If no command is received within this time frame, the CNI will select a port based on the second selection. The second selection is used in both CSD and Internet mode. The choices are Port-1, Port-2, Alternate or None. This is the port that will be selected for an incoming CSD call or if the unit is paged to call back to the central computer. If Alternate is selected then the port selection will alternate with every call. The first call will go to Port-1, the second call to Port-2, the third to Port-1 and so on. See Chapter-6 for more information. 4.3.8 Firmware Version The firmware version is a value that is updated on the screen whenever a ‘Read’ operation is performed. This is not a parameter that can be modified by the user. 4.3.9 Primary Call Retry Rate If the CNI is programmed to originate a call, and the call is unsuccessful for any reason, it will try again at a later time. The CNI can be programmed to wait from 1 to 15 minutes between each attempt. 4.3.10 Primary Call Retry Count This is the number of times (15 maximum) the CNI will try to repeat a call at the “Primary Call Retry Rate”, discussed previously. After this, calls will be attempted at the “Secondary Call Retry Rate”, discussed next. 4.3.11 Secondary Call Retry Interval After the “Primary Call Retry Count” has expired, the “Secondary Call Retry Interval” defines the time between each additional attempt, in 1-hour increments up to a maximum of 15 hours. There is no limit to the number of times the CNI will attempt to place a call at this rate. Once a call is successful, the CNI will return to using the primary retry rate and count.

If this option is selected the radio will remain powered up at all times. This will greatly shorten battery life in battery-operated units, or may exceed the

ability for solar-powered units to maintain a charge on the battery. It may be necessary to use a constant dc power source.

Page 61: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

4-7

4-7

4.3.12 Counter/Status Input-1 If Input #1 of the CNI’s terminal block is to be used for counting pulses, select “Data”. If Input #1 is to be used to monitor an alarm or status switch, select “Alarm”. If the CNI is allowed to originate a call when an Alarm #1 condition occurs, the primary phone number or Internet address will be used. This is shown to the right for reference and is a copy of the “Destination” number near the top of the screen. A special mode called “Transparent Mode” is discussed in detail in Chapter-6. In this mode, the CNI can send readable (ASCII) text strings to the caller or destination to describe the current status, such as “* CUSTOMER ALARM-1 *”, “* TAMPER ALARM *”, etc. If this is desired, check the “Alarm String Download” box. You can also define a custom text string for Input #1 up to 20 characters in length. 4.3.13 Counter/Status Input-2 If Input #2 of the CNI’s terminal block is to be used for counting pulses, select “Data”. If Input #2 is to be used to monitor an alarm or status switch, select “Alarm”. If the CNI is allowed to originate a call when an Alarm #2 condition occurs, you can define a different phone number or Internet address for this condition only. However, the destination doesn’t necessarily have to be a computer. It might be the phone number of a pager, cell phone or warning device to alert someone of a serious situation. A special mode called “Transparent Mode” is discussed in detail in Chapter-6. In this mode, the CNI can send readable (ASCII) text strings to the caller or destination to describe the current status, such as “*CUSTOMER ALARM-2 *”, “* TAMPER ALARM *”, etc. If this is desired, check the “Alarm String Download” box. You can also define a custom text string for Input #2 up to 20 characters in length.

NOTE If one input is to be used for data and the other for alarm monitoring, then always

use Input #1 for data.

Page 62: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com4-8

Page 63: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

4-9

4-9

the destination modem is a Mercury MODSMOD modem bank, you will need at least one 9600 baud modem card installed. For the CDMA18 most common baud rates up to 9600 are supported. The iDEN270 does not support CSD. 4.4.3 Data Bits This value must match the number of data bits used by the external RS-232 device. 4.4.4 Parity Type This value must match the type of parity used by the external RS-232 device. 4.4.5 Stop Bits This value must match the number of stop bits used by the external RS-232 device. 4.5 Serial Port-2 Screen

If you have selected Dual Port mode (discussed earlier), then select the SERIAL PORT 2 tab to continue the configuration. All settings are identical to those for Serial Port 1 except for the Port Select ID. You must assign a unique ID number to the device connected to Port-2. This will allow the central computer to distinguish between the two devices. Legal six-digit values are 000000-FFFFFF (hexadecimal notation). Sequential numbering is not required, nor is it necessary to use any of the hexadecimal digits ‘A, B, C, D, E, or F’.

Page 64: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com4-10

Page 65: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

4-11

4-11

A personal identification number (PIN) as an extra security measure to prevent unauthorized use of a SIM card. The PIN number can range from 1 to 8 numeric digits long and can be assigned by the cellular service provider when the card is activated.

NOTE If a PIN number is not used, leave the PIN Number field blank. Do not fill it with

0’s, because a “0” is a valid PIN digit. 4.6.3 Frequency (GSM18 only) This field only applies to the GSM18. The GSM20 automatically determines which frequency band to use and ignores this setting. Depending upon the service provider chosen and the region of the world in which the CNI is located, there will be a specific frequency band used for the cellular service. These are generally 850 and 1900 MHz in North America, and 900 or 1800 MHz elsewhere. 4.6.4 GPRS Access Point Name (GSM only) This field only applies to GSM radios. If the CNI will be making an Internet connection the cellular service provider will need to provide an Internet APN (access point name). In order to connect to the Internet, the provider has its own computer equipment called a “gateway” server. The server will usually have an APN in the form of a domain name, such as “myserviceprovider.com” or a generic name such as “proxy”. Contact your service provider for this information. Service providers may have several different gateways to choose from, depending upon the type of service required. “Web phones” (cellular phones that support Internet access) are generally assigned to a gateway that only connects to WAP services (wireless application protocol). The CNI requires full Internet access because the data collection software could be running on any server located anywhere in the world. Full access gateways are usually assigned to customers who will be connecting a cellular modem to a personal computer. 4.6.5 Packet Service Connection Command (GSM and CDMA only) This command is issued to the cellular radio to request a packet (Internet) connection. For most GSM cellular service providers the phrase “ATD*99#” will work, and this is the default setting for the CNI in GSM mode. For most CDMA service providers the phrase “ATD#777” will work, and this is the default setting for the CNI in CDMA mode. If you are having problems connecting, this could be the problem. Contact your service provider for more information. 4.6.6 OTAA Programming Number (CDMA only) Unlike GSM radios, CDMA radios do not use SIM (Subscriber Identity Module) cards to hold account information. After purchasing CDMA service the radio must dial a special phone number to be activated and to have account information downloaded into the phone’s memory. This phone number is specific to the carrier and must be entered into the OTAA Programming Number slot in MP32. “OTAA” means over-the-air activation as is discussed in more detail in Chapters 3 and 6.

Page 66: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com4-12 4-12

4.6.7 PAP User Name and Password As an added security measure some cellular service providers use Password Authentication Protocol, or PAP. In order to gain access to their Internet service you must present a user name and a password that was assigned when the cellular service was purchased. The user name or password can be any combination of printable ASCII characters, including spaces, such as “Joe Smith” or “1234”. The total number of characters for both the user name and password cannot exceed 98 characters. The password is hidden on this screen for added security. You must enter the password twice to verify that it was entered correctly.

NOTE If PAP is not required then both the user name and password fields

must be blank. 4.7 Programming the CNI

Figure 4-7

Programming Cables 1) Attach the programming cable to an available communications port on the computer.

See Section 4.2 for more information about communications ports.

2) Attach the opposite end of the interface cable to the 4-position connector (J8) on the CNI board. The connector is keyed and can only insert in one direction.

Page 67: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

4-13

4-13

3) Apply power. The green “PROGRAM MONITOR” light should light solidly. The red “RECEIVE DATA” light should light momentarily and then go out. The green “PROGRAM MONITOR” light should then start flashing once per second. This indicates the CNI is running.

4) Once the parameters have been entered (or read in from a previously-saved

configuration file), select the PROGRAM button to start programming the CNI. Status messages will appear in the lower left-hand corner of the screen. If the CNI is busy with radio operations, it could take up to 30 seconds to respond to the program command. If communications cannot be established within several minutes, check your cable and communications port, and try again.

5) When programming has completed, unplug the 4-pin connector of the cable from the

“J8” connector on the CNI board. The CNI is now ready to be put into service.

Page 68: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com4-14

Page 69: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

5-1

Page 70: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com5-2

5-2

On the next screen select the Data Collection process.

Figure 5-2 Changing the Data Collection Configuration

On the next screen (Figure 5-3) select the “Internet Ports” tab and select the “Add” button near the bottom of the screen. A smaller selection window will appear. Place a checkmark in the “Enabled” checkbox. Select “IMU Server” for the port type. The port number will be filled in automatically, and must match the port number that was programmed into the CNI (see Chapter-4). If this needs to be changed hold down the CTRL key on the keyboard, point to the Port Number box and double click the pointing device (ie – mouse). Then enter a new port number. The default is 50463. Enter the Internet address that was programmed into the CNI. Your computer system’s administrator usually assigns this address. DC-2009 has a number of Internet servers for various Mercury products. A maximum of 255 connections are allowed at the same time for all servers. For instance if there are already 200 connections open for other products, you can only open another 55 connections for the IMU server. If you have 50 devices in the field and only 10 connections open, then only 10 devices will be allowed to connect at any one time. The devices can be scheduled to call in at different times to solve for this.

Page 71: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

5-3

5-3

Figure 5-3 Configuring the IMU Server

5.3 Setting up DC-2009 for CSD connections CSD connections are basically the same as two modems communicating over traditional phone lines. Start the DC-2009 Applications Launcher and select “System Configuration” (see Figure 5-1). On the next screen select the Data Collection process (see Figure 5-2). On the next screen (Figure 5-4) select the “Analog Modem Ports” tab. Most cellular providers that support CSD calls may no longer support baud rates below 9600, and the radios used in the GSM18 and GSM20 do not support rates below 4800. Therefore you will need at least one 9600 baud MODSMOD modem card if you are using a Mercury MODSMOD chassis, or at least a 9600 baud AT-compatible modem. For the CDMA18 most common baud rates up to 9600 are supported. The iDEN270 does not support CSD. In the example shown in Figure 5-4 we have configured DC-2009 for a 9600-baud MODSMOD card on channel-1 using a Mercury software driver. The baud rate selection box near the bottom of the screen is the baud rate between the computer and the MODSMOD card, not between the MODSMOD and the CNI. This baud rate is determined by a set of jumpers on the MODSMOD card. Contact Mercury for more information.

Page 72: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com5-4

5-4

Figure 5-4 Configuring the DC-2009 for CSD Connections

Page 73: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

5-5

Page 74: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com5-6

5-6

Figure 5-6 Defining a Call Profile Name

Page 75: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

5-7

5-7

On the final screen you can define specifically when the device should call in. In Figure 5-7 the CNI will call in at regular 8-hour intervals starting at 14:00:00. Select the Apply button to make the changes permanent.

Figure 5-7 Defining the Call Profile Parameters

An aggressive call schedule may greatly shorten battery life in battery-operated units, or may exceed the ability for solar-powered units to

maintain a charge on the battery. It may be necessary to use a constant dc power source.

Page 76: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com5-8

Page 77: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

5-9

5-9

The next screen will appear. It is not necessary to select a device that’s already been

defined, simply select the ADD icon

Figure 5-9 Remote Unit Selection Screen

On the next screen select “Mercury Types” and OK.

Figure 5-10 Device Type Selection Screen

Page 78: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com5-10

5-10

On the next screen heck the “Active” box to allow this device to be added to the list of all active devices. For devices that will be communicating over the Internet check the “IP Enabled” box. For CSD devices leave this unchecked. Enter the New Remote unit ID (RUID) that was assigned and programmed into the CNI using MP32 (see Chapter-4). Select “IMU” as the product type. Select the Call Profile that is desired. See Section 5.4 for instructions on how to define a new call profile. Battery Type is simply for record keeping and does not alter the operation in any way. The “Copy From Remote Unit” feature allows you to define other CNI’s with similar characteristics to one that’s already defined. For instance suppose you define a new unit with an RUID of 001234. Now you need to define 49 other units but the only difference will be the RUID of each unit. Simply check the “Copy From Remote Unit” box and enter 001234 as the template. Then enter the new RUID in the New Remote unit ID box and select OK. All other parameters will be copied from the original template.

Figure 5-11 Adding a New Unit

Select OK when finished.

Page 79: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

5-11

5-11

Figure 5-12 illustrates one of the ‘tabs’ or ‘folders’ that can be accessed. It is important to select the correct number of data inputs and to instruct the remote device to ‘Send Latest’ data only. Some of the fields (i.e.—Battery Information) are not critical since they exist primarily as a convenience for the system operator.

Figure 5-12 Configuration Setup Screen

Page 80: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com5-12

5-12

Figure 5-3 below illustrates the configuration for the data inputs. It is critical that the interval size setup in DC-2009 matches the interval size that was programmed into the memory of the CNI (Chapter-4). It is possible to assign various names to the data input. In the example below, it has been called “Corrected Volume”.

Figure 5-13 Data Input Configuration Screen

Page 81: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

5-13

5-13

Proper configuration of the call information fields are essential to ensure that data will be collected and available for processing when expected. If the CNI is programmed to originate calls only, then it will not be possible to initiate outbound calls since the cellular radio is not powered to receive any incoming calls. It is common for users to configure the call back times to occur during non-peak hours (evenings or weekends) when the possibility of receiving a busy signal due to network congestion is minimal. Some cellular packages may offer unlimited usage during nights and weekends.

Figure 5-14 Call Profile Screen

Page 82: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com5-14 5-14

Alarms are of benefit to the user since they can be used to report unusual events that might require immediate attention. Alarms that are available for the CNI are: Magnetic Switch Alarm: On the CNI board is a jumper block J2 labeled “CALL”. This is wired in parallel with positions 1 & 2 on the terminal block. Momentarily shorting either connection will cause the unit to place an immediate call to report a “CALL” switch alarm or “MAG” switch alarm. The phrase “MAG” originates from other Mercury products in which a magnetic reed switch is mounted against an inside wall of a non-metallic enclosure. The field technician can trigger a call without opening the enclosure by simply by holding a magnet to the outside wall of the enclosure. The alarm description can be changed to more accurately reflect the exact nature of the alarm, such as “Open Valve” or “Call”. Tamper Detect Alarm: If an external switch is connected to the “Input-1” input on the CNI terminal block, this indicates that the switch is opened. In some unit assemblies this input will be connected to a magnetic reed switch that opens when the enclosure’s door is opened. Customer Alarm 1: If an external switch is connected to the “Input-1” input on the CNI terminal block, this indicates that the switch is closed. Active only if the input is configured as an alarm input. Customer Alarm 2: If an external switch is connected to the “Input-2” input on the CNI terminal block, this indicates that the switch is closed. Active only if the input is configured as an alarm input. Unit Reset Alarm: Reports if the CNI has been reset, indicating that all previously collected data has been lost. Call Retry Alarm: Reports if the previous call attempt was not successfully completed. KYZ-1 Input Failure: Not used. KYZ-2 Input Failure: Not used. Queue 75% Full Alarm: Reported if the CNI data memory is 75% or more full. Clock Resync Alarm: Reported if the CNI’s time-of-day clock has been corrected by more than 20 seconds. Remote Daily Volume Low Input-1,2: Reports if daily volume use is below limits. Remote Daily Volume High Input-1,2: Reports if daily volume use is above limits. Remote TTI Consumption Low Input-1,2: Reports if interval volume use is below limits. Remote TTI Consumption High Input-1,2: Reports if interval volume use is above limits.

Page 83: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

5-15 5-15

AC-Off Alarm: This indicates that the signal connected to the “Power Fail” input has been in a low state for more than five minutes. The alarm description can be changed to more accurately reflect the exact nature of the indication, such as “LOW Battery”. AC-On Alarm: This indicates that the signal connected to the “Power Fail” input has been in a low state for more than five minutes. The alarm description can be changed to more accurately reflect the exact nature of the indication, such as “Battery OK”. Low Battery Alarm: Not used. Figure 5-15 depicts the Hardware Alarm configuration screen. For each alarm condition that occurs you can elect to save that event in a trace file by checking the “Save” checkbox. The event can also be immediately displayed on DC-2009’s alarm handler screen by checking the “Log” checkbox. As each alarm condition is detected the CNI will decide whether to place an immediate call or to report the condition on the next scheduled call. If you wish to have an immediate call for an alarm then check the “Immediate Alarm Notification” checkbox. Note that there are some alarms that always result in an immediate call such as a unit reset. Once a particular alarm is configured, select the “Apply” button to make the changes permanent. You must do this for each alarm.

Note: Changes made to any alarm configuration will not go into effect until the next communication with the CNI.

Page 84: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com5-16 5-16

Figure 5-15 Hardware Alarm Configuration Screen

5.6 Starting the data collection process Once all CNI’s have been defined you can start DC-2009. For CSD connections the appropriate modem channels will be initialized. For packet connections the IMU server will be started and will begin listening on the number of channels that were selected.

Page 85: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

6-1

6-1

6 CNI OPERATION 6.1 Call Retry Strategy If the CNI is configured to originate calls or Internet connections, and a call fails due to a data error or a network problem, the following retry strategy is followed:

1) The first retry will occur from 1 to 15 minutes after the original call, as defined by the Primary Call Retry Rate.

2) Subsequent calls will be made at the Primary Call Retry Rate until the Primary

Call Retry Count is exhausted.

3) Once the Primary Call Retry Count is exhausted, subsequent calls will be made at the Secondary Call Retry Interval, which is defined in hours (1-15). There is no limit to the number of retries that can occur at the secondary rate.

6.2 Paging via Voice Call In CSD mode some cellular service providers allow a mobile device to originate a data call (“mobile-originate”) or to receive one (“mobile-terminate"). For the GSM18 or GSM20 to receive a data call the cellular account must be assigned a “data” phone number. However, some providers do not support mobile-terminate connections or the user may not wish to pay the additional cost of having a separate data number. The CDMA18 does not require a separate data phone number. It uses the same number that is assigned as a voice number. The iDEN270 does not support CSD. Every device connected to the Internet has an Internet protocol (“IP”) address. Devices with “static” IP addresses are typically servers that are always on and always ready to accept a request for communications. Their addresses are well known. Other devices, typically called “clients”, are assigned temporary or “dynamic” addresses that are only valid during the connection. The CNI acts only as a client and therefore can only originate a request for an Internet connection. Therefore it cannot be contacted directly via the Internet. Yet there may be times when it is desirable to communicate immediately with the remote device rather than wait for it to call in. The CNI supports the ability to be “paged. Many cellular accounts are (or can be) assigned a “voice” phone number. If the CNI is configured to answer incoming phone calls it is possible to use this as a paging number which will then trigger the CNI to immediately call back to the central computer. In CSD mode GSM and CDMA units will answer the call and will attempt to communicate with the remote modem if there is one. The call will be terminated if 30 seconds pass without a successful modem exchange or if the other end hangs up. This will trigger the unit to immediately call back to the primary phone number. The iDEN270 treats all incoming calls as pages and does not attempt a CSD connection. In packet (Internet) mode the unit will answer the call and will immediately hang up. It will then originate an Internet connection to the primary IP address and port number.

Page 86: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com6-2 6-2

6.3 Paging via SMS Message SMS (short message service) was developed to allow short text messages to be sent to cellular phones. These messages are not sent via the Internet but over a radio channel designated to carry Unstructured Supplementary Services Data (USSD). When the CNI receives an SMS message it will immediately call back to the primary IP address and port number, or to the CSD phone number that has been programmed into the unit. The cellular service provider will give you instructions on how to send text messages to the mobile device. Often the SMS address includes the account’s voice phone number, such as [email protected] or something similar. It is worth noting that SMS is a low-priority feature on some networks and they may not be delivered immediately. 6.4 What Causes the CNI to Call In? First, the CNI must be configured to originate calls. See Chapter-4 for programming instructions. Second, most alarms conditions can be configured to generate an immediate call. See Chepter-5 for this information. All calls are made to the primary phone number or IP address, except for Alarm Input #2, which can be assigned a different phone number or Internet address. 6.4.1 Alarm Condition For any alarm condition described in Chapter-5 the CNI can be programmed to place an immediate call into DC-2009. 6.4.2 Paging The CNI can be paged by calling its voice number or by sending it an SMS message. The unit will call in but does not report an alarm condition for a page. 6.4.3 Scheduled Call Each time the CNI communicates with DC-2009 it will be given a new time to call in. This schedule is defined by the user using the Call Profile Configuration Screen in DC-2009 (see Chapter-5).

The use of paging requires that the radio will remain powered up at all times. This will greatly shorten battery life in battery-operated units, or may exceed the

ability for solar-powered units to maintain a charge on the battery. It may be necessary to use a constant dc power source.

The use of paging requires that the radio will remain powered up at all times. This will greatly shorten battery life in battery-operated units, or may exceed the

ability for solar-powered units to maintain a charge on the battery. It may be necessary to use a constant dc power source.

Page 87: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

6-3 6-3

6.5 Behavior when Originating a Call in CSD Mode Figure 6-1 depicts the status LEDs on the CNI board.

Figure 6-1 CNI’s LED Indicators

When power is first applied to the CNI or when the unit is reset the green “program monitor” LED will light steadily for several seconds then should start flashing slowly. If this is a CDMA18 an over-the-air-activation call will be attempted first (see Section 6.13). Otherwise if the CNI has been configured to originate a CSD call, it will attempt to make a call to the primary phone number that was been programmed into the CNI. The reason for the call is to report a “unit reset” alarm.

• First, the CNI applies power to the cellular radio and will initialize the radio for data communications. During this time the “program monitor” LED will flash very slowly. When the radio is ready, the “program monitor” LED will flash twice as fast.

• The cellular radio will attempt to “register” with the cellular network. If the radio is

able to register with the network, the signal strength is checked. If the signal strength is very good the “program monitor” LED will flash very rapidly. If the signal strength is weak but usable the LED will flash at a somewhat slower rate. Good signal strength is equivalent to 3 or more “bars” on a typical cellular phone.

NOTE: If the radio cannot register with the network within several minutes, the CNI will attempt to call again at a later time. That time is defined as either the “Primary Call Retry Rate” or “Secondary Call Retry Rate” depending upon how many attempts have been made so far.

• The “call in progress” LED will light solid red. The phone number is dialed. If a

connection is established with the central computer’s modem the “carrier detect” LED will light solid red. If a link cannot be established the CNI will power down the radio and try again at a later time.

• If a modem connection is established the “transmit data” and “receive data” lights

will blink randomly, indicating that data is being exchanged with the central

Page 88: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com6-4

6-4

computer.

• At the end of the call the “call in progress” and “carrier detect” LEDs will turn off. If the call was successful both of the “good call” LEDs will light solid red. If the call was not successful due to data errors or the loss of a connection the CNI will attempt to call again at a later time.

A CSD connection will be terminated if:

• The central computer terminates its connection • No data has been received from either the computer or the external serial

device for one minute • The cellular connection has been lost

• 4 – 5 minutes after the initial power-up or reset, if the CNI is only allowed to

originate calls and not respond to pages or incoming calls, all LEDs will turn off and the CNI will go into a low-power standby mode to conserve power.

Additional calls can now be made. For each additional successful call both of the “good call” LEDs will light solid red for about 3 seconds before the unit returns to a low-power standby mode. 6.6 Behavior when Answering a Call or Page in CSD Mode If the CNI has been configured to answer a CSD call the cellular radio module is powered up at all times in order to detect the incoming calls. Therefore it is normally always registered with the cellular network, unless the signal strength is poor.

• Every 20 seconds the signal strength is checked. If the signal strength is very good the “program monitor” LED will flash very rapidly. If the signal strength is weak but usable the LED will flash at a somewhat slower rate. Good signal strength is equivalent to 3 or more “bars” on a typical cellular phone.

• When an incoming call is detected the CNI answers the call, usually on the first

ring. The “call in progress” LED will light solid red.

• GSM and CDMA units will attempt to establish communications with the central computer’s modem. If this is successful the “carrier detect” LED will light solid red. If a link cannot be established within for 30 seconds the CNI will terminate the call. (The iDEN270 will not attempt to make a CSD connection and will simply hang up.) At this point the call is considered to be a “page” and, if the CNI has been configured to originate calls, will call back to the primary phone number that was programmed into the unit.

• If a modem connection is established the “transmit data” and “receive data” lights

will blink randomly to indicate that data is being exchanged.

• At the end of the call the “call in progress” and “carrier detect” LEDs will turn off. If the call was successful both of the “good call” LEDs will light solid red. The CNI will go back to listening for more incoming calls.

Page 89: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

6-5 6-5

A CSD connection will be terminated if:

• The remote computer terminates its connection • No character has been received from either the computer or the external

serial device for one minute • The cellular connection has been lost

6.7 Behavior in Packet Mode When power is first applied to the CNI board or when the unit is reset the green “program monitor” LED will light steadily for several seconds then should start flashing slowly. If this is a CDMA18 an over-the-air-activation call will be attempted first (see Section 6.13). Otherwise if the CNI has been configured for packet (Internet) mode it will attempt to make a connection to the primary IP address that was been programmed into the CNI. The reason for the call is to report a “unit reset” alarm.

• First, the CNI applies power to the cellular radio and will initialize the radio for Internet communications. During this time the “program monitor” LED will flash very slowly. When the radio is ready the “program monitor” LED will twice as fast.

• The cellular radio will attempt to “register” with the cellular network. If the radio is

able to register with the network the signal strength is checked. If the signal strength is very good the “program monitor” LED will flash very rapidly. If the signal strength is weak but usable the LED will flash at a somewhat slower rate. Good signal strength is equivalent to 3 or more “bars” on a typical cellular phone.

NOTE: If the radio cannot register with the network within several minutes the CNI will attempt to call again at a later time. That time is defined as either the “Primary Call Retry Rate” or “Secondary Call Retry Rate” depending upon how many attempts have been made so far.

• The CNI will request a packet service connection with the cellular provider. If

granted the “call in progress” LED will light solid red. Otherwise the CNI will try again at a later time.

• A request is made for an Internet connection to the server whose IP address was programmed into the CNI. During this time the “transmit data” and “receive data” lights will blink randomly, indicating that data is being exchanged between the CNI and the cellular provider.

• If a connection is established to the server the “carrier detect” LED will light solid

red. If a link cannot be established, the CNI will try again at a later time.

• The “transmit data” and “receive data” lights will blink randomly indicating that data is being exchanged between the CNI and the destination server.

• At the end of the call the “call in progress” and “carrier detect” LEDs will turn off.

If the call was successful both of the “good call” LEDs will light solid red. If the

Page 90: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com6-6

6-6

call was not successful due to data errors or the loss of a connection the CNI will attempt to call again at a later time.

• 4 – 5 minutes after the initial power-up or reset, if the CNI is only allowed to

originate calls and not respond to pages or maintain a permanent Internet connection, all LEDs will turn off and the CNI will go into a low-power standby mode to conserve power.

Additional calls can now be made. For each additional successful call both of the “good call” LEDs will light solid red for about 3 seconds before the unit returns to a low-power standby mode. 6.8 Permanent (“Always On”) Internet Connection When the CNI is programmed to only originate calls it returns to a low-power standby mode after the completion of a call. This means the radio is turned off and the connection to the cellular network is terminated. When it’s time to place the next call the radio must be powered up, the registration must be reestablished, a packet service connection requested and granted, and an Internet connection requested and granted to the data collection server. Of course all of this takes time, sometimes several minutes if the network is busy. A feature that is available from most cellular providers is an “always on” Internet connection. By staying connected to their system it is only necessary to request a connection to the destination server. This normally requires just a few seconds. To enable this feature program the CNI for originate mode and check the “Maintain Internet Connection” checkbox in MP32 (see Chapter-4). In this mode the CNI will not be able to answer incoming calls or respond to SMS messages. In this mode the “call in progress” LED will remain on to indicate a permanent connection to the Internet. The remaining LED indicators will behave as they do during a normal Internet connection.

If this option is selected the radio will remain powered up at all times. This will greatly shorten battery life in battery-operated units, or may exceed the

ability for solar-powered units to maintain a charge on the battery. It may be necessary to use a constant dc power source.

Page 91: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

6-7 6-7

6.9 Transparent Mode for Alarm Status and Maintenance This feature is only supported in CSD mode and then only for GSM and CDMA units. When placing or receiving a CSD call, the CNI will always attempt to communicate with DC-2009 first. After the modem connection is established the CNI will send a special ASCII string and wait several seconds for a valid Mercury (legacy) protocol response. It will repeat this sequence several more times. If a valid response is still not received the CNI switches to “Transparent Mode”. Transparent mode allows a non-Mercury system (such as a modem and a computer running a terminal emulation program such as HyperTerminal) to use the CNI as an alarm-monitoring device. Pulse counting information is not available in this mode. It also allows the computer to communicate with a serial device connected to the CNI’s serial port. This is discussed in the next sections. If either of the CNI’s inputs has been configured as an alarm input, and the “Alarm String Download” function has been enabled, the CNI will immediately send one or more ASCII text strings relating to its status and alarm conditions. A single carriage-return character (13 decimal or 0d hex) terminates each string. The first string sent is:

UID# xxxxxx

where “xxxxxx” is the 6-digit remote unit ID that was programmed into the CNI (see Chapter-4). If there are no alarm conditions, this is the only string sent. Otherwise any of the following strings may be sent relating to status and alarm conditions (see Chapter-5 for a description of the various alarm conditions):

* CALL RETRY ALARM * * UNIT RESET ALARM *

* TAMPER ALARM * * CUSTOMER ALARM *

* AC OFF ALARM * * AC ON ALARM *

* CUSTOMER ALARM 1 * * CUSTOMER ALARM 2 *

Note: “* Customer Alarm 1 *” and “* Customer Alarm 2 *” are default strings for Input #1 and #2, respectively. These strings can be changed when configuring the device. See Chapter-4. The CNI can also respond to several short command strings from the computer, shown in the next table. A single carriage-return character (13 decimal or 0d hex) must terminate all strings. Upper or lower case characters are accepted.

Page 92: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com6-8 6-8

COMMAND DESCRIPTION

+-+CA +-+CLRALMS

Clear Alarms. All alarm conditions that were present at the time of the call are cleared. If the CNI originated a call due to an alarm condition, this command will prevent the CNI from calling again. The CNI will respond with an “OK” string after the alarms are cleared.

+-+SA Send Alarms. The CNI will return the unit ID string followed by other strings describing any alarm or status conditions. See the previous discussion about these messages.

+-+AA +-+AUTALMS

Auto Alarm Clear. When this command is received, alarm conditions will be automatically cleared after each call (including this call). Therefore it is not necessary to issue the +-+CA or +-+CLRALMS command with each call. This command only needs to be issued once. The CNI will respond with an “OK” string after this command is accepted.

+-+MA +-+MANALMS

Manual Alarm Clear. When this command is received, alarm conditions can only be cleared using the +-+CA or +-+CLRALMS command. The CNI will respond with an “OK” string after this command is accepted.

+-+PAxxxxxx Port Address, where “xxxxxx” is the 6-digit remote unit ID that was programmed into the CNI for the serial ports (see Chapter-4). This is used when communicating with two external serial devices connected to the CNI’s serial port.

Table 6-1

CSD Transparent Mode Status Commands 6.10 Transparent Mode for One External Serial Device This feature is only supported in CSD mode and then only for GSM and CDMA units. In addition to monitoring alarm conditions and counting pulses, an external serial device can be connected to the CNI. The device might be a pressure transducer, a temperature sensor, a gas volume corrector or any device capable of RS-232 communications. There is also an adapter card available that allows two serial devices to share the same port. This mode is discussed in the next section. Serial devices often have their own unique communications protocols of commands and responses, but the CNI does not have this information. However, the “Transparent Mode” allows the serial device to communicate directly with the system that is being called or is calling. That system should know how to communicate with the serial device. The CNI simply passes the information back and forth between the two devices. Chapter-2 describes the RS-232 serial port. Characteristics such as baud rate and parity are configured using the Mercury Programmer (MP32) software. This is discussed in Chapter-4. When placing or receiving a CSD call, the CNI will always attempt to communicate with a Mercury modem system first. After the modem connection is established, the CNI will

Page 93: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

6-9

6-9

send a special ASCII string and wait several seconds for a valid Mercury (legacy protocol) response. It will repeat this sequence several more times. If a valid response is still not received, the CNI switches to “Transparent Mode”. If either of the CNI’s inputs has been configured as an alarm input, and the “Alarm String Download” function has been enabled, the CNI will immediately send one or more ASCII text strings relating to its status and alarm conditions. The CNI can also respond to several short command strings from the computer. See the previous section about this. After this, any characters received from the computer will be passed along to the serial device, and any characters received from the serial device will be passed along to the computer. The CNI will always be looking for the commands listed in Table 6-1. If any are received, they will be processed as described in the previous section. The connection will be terminated if:

• The remote computer terminates its connection • No character has been received from either device for one minute • The cellular connection has been lost

6.11 Transparent Mode for Two External Serial Devices This feature is only supported in CSD mode and then only for GSM and CDMA units. If using a dual port multiplexer, the +-+PAxxxxxx command allows the computer to select one of the two ports. See Chapter-4 for more information about dual port mode. For example, if the primary unit ID is 123456 (which is also the ID for Serial Port-1), and the ID for Serial Port-2 is 987654, then the command to select Port-2 would be

+-+PA987654

The CNI will respond with the string

CONNECTION WITH PORT 987654 NOW TRANSPARENT After this, any characters received from the computer will be passed along to the serial device, and any characters received from the serial device will be passed along to the computer. The CNI will always be looking for the commands listed in Table 6-1. If any are received, they will be processed as described in the previous section. For incoming calls, the CNI can be configured to select a port without the need for the Port Address command. See Chapter-4 for more information.

Page 94: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com6-10 6-10

6.12 Power Failure Standby Mode See Chapter-2 about the use of the “Power Fail” input. In some applications there will be a main source of power and possibly a backup source such as a battery. To preserve the backup source here is how the CNI behaves before, during and after a power failure:

1) If the signal at the “Power Fail” input has been low (0V) for longer than 3-4 minutes the CNI will log an “AC-OFF” alarm. If the unit has been configured to originate calls it will attempt to report it to the central computer. If the call fails it will try again at a later time. That time is defined as either the “Primary Call Retry Rate” or “Secondary Call Retry Rate” depending upon how many attempts have been made so far.

2) If the unit has been configured to answer phone calls, receive SMS messages or

maintain a permanent IP connection, those modes are temporarily cancelled.

3) The radio will be powered down and the CNI will enter a low-power sleep mode. During this time all LEDs are turned off.

4) The CNI will still count pulses and respond to alarm conditions, and will wake up

and place calls under alarm conditions. It will return to sleep mode after each call is placed. However, the unit will not retry calls that are unsuccessful except for the call to report the “AC-OFF” alarm.

5) When the signal at the “Power Fail” input has been high (>3.5V) for longer than

3-4 minutes the CNI will log an “AC-ON” alarm. If the unit has been configured to originate calls it will attempt to report it to the central computer.

6) The CNI will restore itself to the conditions that existed prior to the power failure

condition.

As mentioned in Chapter-5, the “AC-OFF” and “AC-ON” alarms can be renamed in DC-2009 to something more meaningful, such as “LOW BATTERY” and “BATTERY OK”. 6.13 Over-the-Air Activation (CDMA18 only) CDMA technology does not support the use of a SIM card (Subscriber Identity Module) to hold and transport account information. Therefore the account information must be downloaded into the cellular module’s own memory. This is accomplished by dialing a special phone number to request an “over-the-air-activation” (OTAA). The activation phone number is specific to the service provider and must be programmed into the CNI using the MP32 configuration software (Chapter-4). The OTAA process does two things. After the first successful OTAA call a new phone number is programmed into the phone. This is the number that can be used to page the unit via a voice or data call, or via an SMS message. It also starts the account billing

Page 95: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

6-11

6-11

process. Second, a “preferred roaming list” (PRL) is downloaded into the phone. This instructs the radio which service provider(s) to search for and connect to. Over-the-air activation is attempted whenever the unit is reset. Another call will be attempted if the first one fails. After two unsuccessful attempts the CNI will go into an idle mode and will attempt another OTAA call every hour until one is successful. Until then the unit will not be able to call in to the data collection system. After the first successful call an OTAA call is performed every 7 days. The reason for this is that cellular service providers often make arrangements with other providers to carry calls in areas where their own equipment and towers do not exist. These agreements allow the call to be forwarded at no additional charge. The preferred roaming list says that it is acceptable to connect with these carriers. However at some point your service provider may install new equipment in these areas, and the contract with the partner may be terminated. In this new situation roaming fees will be added to each call if the radio is allowed to connect to the other carriers. This is why it is important to periodically update the PRL. Here is how the CNI behaves during an OTAA call:

• First, the CNI applies power to the cellular radio and will initialize the radio for data communications. During this time the green “program monitor” LED will flash very slowly. When the radio is ready, the “program monitor” LED will flash twice as fast.

• The cellular radio will attempt to “register” with the cellular network. If the radio is

able to register with the network, the signal strength is checked. If the signal strength is very good the green “program monitor” LED will flash very rapidly. If the signal strength is weak but usable the LED will flash at a somewhat slower rate. Good signal strength is equivalent to 3 or more “bars” on a typical cellular phone.

NOTE: If the radio cannot register with the network within a few minutes, the CNI will attempt to call again at a later time. That time is defined as either the “Primary Call Retry Rate” or “Secondary Call Retry Rate” depending upon how many attempts have been made so far.

• The “call in progress” LED will light solid red. The OTAA phone number is dialed

(this was programmed into the CNI using MP32). If a connection is established with the cellular provider both the “call in progress” and the “carrier detect” LEDs will flash together slowly.

• For the next 1 –2 minutes the cellular provider should download a new phone

number if needed and a new PRL. When the call has finished both the “call in progress” and the “carrier detect” LED will turn off, and the “transmit data” and “receive data” LEDs will light solidly for at least several seconds.

• If this first attempt fails, a second call is attempted.

• If the second call fails, the CNI will do one of two things. If an OTAA call has

Page 96: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com6-12

6-12

never been successful the CNI go into an idle mode and the OTAA call will be retried every hour until successful. Otherwise the CNI will continue with its normal operation and will attempt the next OTAA call in 7 days and every 7 days thereafter.

IMPORTANT NOTES ABOUT CDMA ACTIVATION Remember, a cellular account must be purchased prior to activating the radio. You usually have to provide the “ESN” number of the radio to the cellular service provider. This is printed on a label on the c18 radio as shown back in Figure 3-4.

Also check the OTAA phone number that was programmed using MP32 (see Chapter-4). Some service providers may have different OTAA phone numbers to use depending upon geographical location. If you continue to have problems you may have to contact your service provider. When you order a CDMA18 Mercury will reserve a radio for that order and will send you its “ESN” number. It is highly recommended that you purchase service prior to Mercury shipping your order. If we know that the account has been established we will activate and fully test the radio prior to shipment. Without an account we cannot fully test the unit. The downside is that the account billing usually starts the moment the radio is activated. You may not wish to install the unit for a while but you will still be paying a monthly cellular bill. It may be possible to ask your service provider to “suspend” the account after it has been received from Mercury. This places the account in a non-billing holding pattern until you are ready to use it.

Page 97: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

7-1

7-1

7 Battery-Operated Unit Assembly 7.1 Description The battery-powered CNI consists of the CNI board, a power supply board, a rechargeable lead-acid battery, an alkaline battery (for charging the lead-acid battery) and a NEMA 4X enclosure.

Figure 7-1

Battery-Powered Unit Assembly

Page 98: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com7-2 7-2

7.2 Unpacking, Damage reports, Item List

Upon receipt, inspect the CNI for any potential shipping damage. If any damage is detected that can be attributed to the way the package was handled, then a claim should be filed with the shipping agent as quickly as possible. A typical battery-powered CNI is provided with the following items:

• The Model GSM18, GSM20, CDMA18 or iDEN270 Cellular Network Interface card with Motorola g18, g20, c18 or iO270 cellular radio module

• “IMU-DC” firmware option • Antenna • Power supply board. • 12-volt, 2.5 A-hr sealed lead-acid battery • 6-volt alkaline lantern battery (for charging the lead-acid battery) • Nema 4X enclosure • Manual 900349 (this document). Normally only one manual is included with each

shipment rather than with each unit. Additional manuals can be ordered separately or obtained in PDF file format upon request.

Note: The items listed above may vary depending on what was requested with the original purchase order. Refer to the shipping document or the purchase order for a precise record when inspecting the package contents.

Never transport the unit with the lead-acid battery installed! A loose battery will damage the circuit boards.

Page 99: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

7-3 7-3

7.3 Unit Assembly Dimensions

Figure 7-2

Enclosure Dimensions

Page 100: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com7-4 7-4

7.4 Electrical Wiring Diagram

Figure 7-3

Electrical Wiring Diagram

Page 101: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

7-5

7-5

7.5 Power Supply Board

Figure 7-4

1001-0308-002 Power Supply Board

Figure 7-5 1001-0316-002 Power Supply Board

There is one of two power supply boards used depending upon the age of the unit. The charging source for the power supply board is typically a 6-volt alkaline lantern battery. Any other filtered dc supply can be used as long as the voltage range is between 4.0 and 6.5 V. The battery connects to the TB2 connector (Pin-1 is positive and Pin-2 is ground).

Page 102: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com7-6

7-6

The power supply board provides four functions. First, the board provides a regulated, low current (100mA) +4.2V supply for the CNI board. It is the primary power source when the radio is not being used and maintains the processor circuits and memory. This supply appears on the J3 connector of the power supply board (J3-1 is positive and J3-2 is ground). It connects to the J3 connector on the CNI board (J3-4 is positive and J3-1 is ground). When the radio is powered up the CNI generates a logic high signal on its J6 connector that causes the power supply board to turn on a high-current supply (J6-3 is signal and J6-2 is ground). This logic signal is connected to the J3 connector on the power supply board (J3-5 is signal and J3-6 is ground). The 12V high-current output appears on the J2 connector of the power supply board (J2-1 & 4 are positive and J2-2 & 3 are ground). The supply is connected to the TB2 terminal block on the CNI board (Pin-1 is positive and Pin-2 is ground). This supply provides the high current demanded by the radio. This supply voltage is regulated down to +5V on the CNI board. The third function is to supply a constant charging voltage for the lead acid battery. It is this battery that supplies most of the current for radio operations. The alkaline battery is simply a charging source. The lead acid battery is connected to the J1 connector (J1-2 is positive and J1-1 is ground). Nominal charging voltage is 13.5V. Finally the board monitors the condition of the alkaline battery and reports a low-battery condition to the CNI when the battery voltage reaches approximately 3.6V. This is a logic low signal that appears on the J3 connector (J3-3 is signal and J3-4 is ground). It is connected to the J6 connector on the CNI board (J6-1 is signal and J6-2 is ground). The 1001-0316-002 board also provides a regulated 5V, 100 mA supply on the TB3 terminal block (Pins-1 & 3 are positive and Pins-2 & 4 are ground). This supply may not be used in some assemblies.

Page 103: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

7-7 7-7

7.6 Lead Acid Battery Installation A 12V, 2.5 Ahr sealed lead acid battery provides backup power and the brief but heavy current requirements of the cellular radio. The lead acid battery is shipped separately to prevent damage to the electronic components, and to satisfy regional rules regarding the shipment of hazardous materials. The battery is easily installed as shown in Figure 7-6. Once the battery is installed, locate the two-wire cable with the white connector that is plugged into J1 on the power supply board. Follow these steps:

1) Unplug the white connector from the J1 connector on the power supply board. Grasp and squeeze the ears on the connector, then pull out.

2) Connect the red wire to the positive (+) terminal on the battery. 3) Connect the black wire to the negative (-) terminal on the battery.

Figure 7-6 Installation of the lead acid battery

Page 104: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com7-8 7-8

7.7 External Antenna Kit Every CNI enclosure has been pre-drilled with a 1/4" diameter hole at the upper left-hand side of the enclosure wall or on the door. It is necessary to push out the small black hole plug and clean away any residual silicon sealant. As shown back in Figure 2-14 the SMA female end of the cable is then pressed through the enclosure wall and fastened into place using the provided washer and nut. When securing the antenna onto the SMA connector, ensure that the fitting is tightened sufficiently by hand (tools are not required), and that the antenna is vertically orientated. The opposite end of the cable with the MMCX or U.FL connector end is pressed onto the mating connector of the Motorola cellular radio. 7.8 TAMPER Alarm The TAMPER alarm input has been pre-wired with a magnetic switch that activates when the door of the enclosure opens. The switch can be disconnected and the TAMPER input can be used for another purpose if desired. This is a Form-B (normally closed) input that will respond when the switch opens. 7.9 Low Battery Alarms The “Power Fail” alarm input has been pre-wired to accept a battery status signal from the power supply board. An AC-OFF alarm will be reported if the lantern battery’s voltage falls below 3.6V for more than 5 minutes. After an AC-OFF alarm is reported an AC-ON alarm will be reported when the lantern battery’s voltage exceeds 3.6V for longer than 5 minutes. The description of these alarms can be changed in DC-2009 to be more meaningful, such as “Low Battery” and “Battery OK”. 7.10 Notes About Battery Life Lead-acid battery life expectancy is 2-4 years. As with automotive batteries, temperature plays a key role in determining how long the battery will survive. Charge and discharge cycles are also important, and this will depend upon how the unit is configured. If the CNI makes frequent calls, the long-term life of the lead-acid battery will decrease. The alkaline lantern battery is the “disposable” member of the power supply. Its sole purpose is to charge the lead-acid battery. Again, life will depend upon how the unit is configured. If the CNI makes frequent calls, the long-term life of the alkaline battery will suffer. The alkaline battery alone may not be able to supply the high current needed by the radio. Battery voltage may drop in severely cold weather, and return to normal limits as it warms up. Occasional low-battery messages may not necessarily mean that the

Page 105: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

7-9

7-9

alkaline battery needs to be replaced. However, repeated alarms could signal a weak battery and it should be replaced as soon as possible.

a) Check the voltage of the lantern battery while it is in service, particularly just after a cellular call. This will be the time when the most current is drawn from the battery as it recharges the lead acid battery. Acceptable levels are from 6.3V down to 3.6V.

b) Check the voltage of the lead acid battery while it is in service. A fully charged

battery should measure above 12V while in standby mode. If the voltage drops below 10V during a cellular call, the lead acid battery may need to be replaced.

c) If it appears that the power supply is not performing properly, check the fuses at

locations F2 and F3 on the power supply board. Replacement fuses are available from Mercury.

Page 106: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com7-10

Page 107: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

8-1 8-1

8 AC-Powered (“Configuration-1”) Unit Assembly

8.1 Description

The ac-powered CNI consists of the CNI board, an ac power supply board, an optional battery backup system and a NEMA 4X enclosure.

Figure 8-1

AC-Powered (“Configuration-1”) Unit Assembly

8.2 Unpacking, Damage reports, Item List Upon receipt, inspect the CNI for any potential shipping damage. If any damage is detected that can be attributed to the way the package was handled, then a claim should be filed with the shipping agent as quickly as possible. A typical AC-powered CNI is provided with the following items:

• The Model GSM18, GSM20, CDMA18 or iDEN270 Cellular Network Interface card with Motorola g18, g20, c18 or iO270 cellular radio module

• “IMU-DC” firmware option

Page 108: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com8-2

8-2

• Antenna • Power supply board. • Optional lithium backup batteries • Nema 4X enclosure • Manual 900349 (this document). Normally only one manual is included with each

shipment rather than with each unit. Additional manuals can be ordered separately or obtained in PDF file format upon request.

Note: The items listed above may vary depending on what was requested with the original purchase order. Refer to the shipping document or the purchase order for a precise record when inspecting the package contents.

8.3 Unit Assembly Dimensions

Figure 8-2 Mounting Tab Locations

Page 109: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

8-3 8-3

Figure 8-3

Enclosure Dimensions

CAUTION If using metallic conduit connectors, the non-metallic enclosure does

not provide grounding between the conduit connectors. Use grounding bushings and jumper wires to achieve the necessary grounding.

Mounting of the unit is normally accomplished by bolting the enclosure to a wall or other support structure. The four mounting tabs are capable of accepting bolts of 5/16” (0.312”) maximum diameter, although smaller bolts can be used with washers. Figure 8-4 provides an illustration of one of the enclosure mounting tabs.

Figure 8-4

Enclosure Mounting Tab (1 of 4)

Page 110: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com8-4 8-4

8.4 AC Power Cable Wiring Connection

Removal of the safety shield is only to be performed after it has been confirmed that the AC mains power has been disconnected at the source.

Figure 8-5

Metal Safety Shield Entry for the AC mains power is at the right-hand side conduit hole. Three connection points are available at terminal block TB1: AC Line, AC Line, and Earth Ground (see Figure 8-6). It is mandatory that an earth ground connection be made to protect service personnel from the possibility of an electric shock hazard. In addition, the metal safety shield must be replaced before AC power is applied to guard against accidental contact with components carrying high voltage potentials.

Page 111: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

8-5

8-5

Figure 8-6

Routing and Connection of AC Mains Power 8.5 AC Voltage Selection Refer to Figure 8-6 for the location of the line voltage selector switch. Select either 115 or 230 VAC, depending upon the actual line voltage to be used.

CAUTION It is extremely important that the line voltage selector switch setting matches the actual line voltage. Damage or personal injury could

result if the setting is incorrect!

Page 112: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com8-6 8-6

8.6 Lithium Backup Battery Installation Battery backup is an optional feature that allows the CNI to continue normal operation during a power failure. There are two ‘C’ type battery holders located on the power supply board, below the CNI board. The cut away in Figure 8-7 shows their locations.

Figure 8-7

Installation of the Backup Batteries

NOTE Only 3.6V lithium batteries should be used. Standard alkaline or NiCad batteries

will not provide enough voltage or current to operate the unit. See Chapter-12 for the recommended battery type.

Page 113: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

8-7

8-7

NOTE The unit will begin to operate as soon as the backup batteries are installed. It is best to prepare the unit to operate from AC power before installing the batteries.

AC power should be applied soon after the batteries are installed. This will preserve the life of the batteries.

Follow these steps for battery installation:

1) Remove AC power. 2) Remove the two screws from the left side of the CNI board (see Figure 8-7). 3) The CNI board is also secured with a nylon standoff located below the cellular

radio. See Figure 8-7 for its location. Gently lift up on the CNI until the standoff separates from the CNI board. Do not remove the radio from the board.

4) Lift the CNI board up to gain access to the battery holders.

5) For the GSM18 only, if you have not installed the SIM card, now would be a good

time to do this. See Chapter-4 for instructions. The SIM card for the GSM20 can be installed without removing the CNI board.

6) Install two lithium ‘C’ batteries, observing the + polarity marker.

7) Lower the CNI board down onto the nylon standoff. Gently circulate the board

until the standoff finds its mating hole on the CNI board. Now press down on the board until the standoff snaps into place.

8) Install the two screws on the left side of the CNI board.

9) Restore AC power as soon as possible.

Page 114: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com8-8

8-8

8.7 Electrical Wiring Diagram

Figure 8-8

Electrical Wiring Diagram

Page 115: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

8-9 8-9

8.8 Power Supply Board

Figure 8-9 AC Power Supply Board

The large circuit board in the unit serves the dual purpose of acting as the mounting platform for the CNI board, as well as providing the regulated DC power source for the CNI and cellular radio module. Here is a brief description of these components:

• Fuse F1: Serves to protect both the user and the electronics in case of a surge or overload condition.

• Terminal Block: Entry point for the AC mains power. Three conductors are

necessary for the connection: AC line, AC line, and Earth Ground.

• Transformer T1: Converts the AC mains power to a lower voltage level that can then be utilized by the regulator electronics. In addition, the transformer provides isolation between the primary (high voltage) and the secondary (low voltage) for

Page 116: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com8-10

8-10

user safety.

• Voltage selector S1: Selects operation between 115 and 230 VAC

• Bridge Rectifier DB1: Provides full-wave rectification of the AC power signal from the transformer, which results in a pulsating DC waveform.

• Capacitors C1, C2, C7: Serves to ‘smooth-out’ the ripples from the pulsating DC

power signal coming from the bridge rectifier.

• Voltage Regulator U1: Converts the filtered DC power signal to a highly regulated 5v output voltage that varies relatively little regardless of the applied load.

• LED D8: Provides a simple indicator to the user that the power supply is

operating. Caution is advised however since failure of this light to illuminate does not necessarily mean that the AC mains power is absent. It should always be assumed that the AC mains power is present at the terminal block until confirmed otherwise.

• Connector J3: J3 is the connector that routes power and the AC status signal to

the CNI board.

• Battery Holders BATT1, BATT2: These holders are optional. Two 3.6V lithium ‘’C” batteries are installed here to provide backup power when the main AC line fails.

• Surge Protectors D1, D4, D5: Protect the circuitry from damage during high input

voltage conditions, such as those caused by lightning strikes.

• Jumper Block JP1: For this application there should be a jumper block located between the ‘B’ and ‘C’ terminals.

Page 117: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

8-11

8-11

Figure 8-10

Block Diagram of the Power Supply Board

8.9 Wiring External Devices to the CNI Board

Use the left-hand cable gland to route all data and alarm inputs to the CNI’s terminal block, as shown in Figure 8-11. The right-hand cable gland should only be used for AC power lines. Once the cables are routed through the gland tighten the shroud in the clockwise direction. There is a rubber insert in the shroud that compresses around the cables and seals the unit from water and insects.

Page 118: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com8-12

8-12

Figure 8-11

Cable Routing to the CNI 8.10 External Antenna Kit Every CNI enclosure has been pre-drilled with a 1/4" diameter hole at the upper left-hand side of the enclosure wall or on the door. It is necessary to push out the small black hole plug and clean away any residual silicon sealant. As shown back in Figure 2-14 the SMA female end of the cable is then pressed through the enclosure wall and fastened into place using the provided washer and nut. When securing the antenna onto the SMA connector, ensure that the fitting is tightened sufficiently by hand (tools are not required), and that the antenna is vertically orientated. The opposite end of the cable with the MMCX or U.FL connector end is pressed onto the mating connector of the Motorola cellular radio.

Page 119: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

8-13 8-13

8.11 TAMPER Alarm The TAMPER alarm input has been pre-wired with a magnetic switch that activates when the door of the enclosure opens. The switch can be disconnected and the TAMPER input can be used for another purpose if desired. This is a Form-B (normally closed) input that will respond when the switch opens. 8.12 Low Battery Alarms The “Power Fail” alarm input has been pre-wired to accept a battery status signal from the power supply board. An AC-OFF alarm will be reported if the ac power has failed for more than 3-4 minutes. After an AC-OFF alarm is reported an AC-ON alarm will be reported when the ac power has been restored for longer than 3-4 minutes.

Page 120: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com8-14

Page 121: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

9-1

9-1

9 AC-Powered (“Configuration-2”) Unit Assembly

9.1 Description

The AC-powered CNI consists of the CNI board, a power supply board, a rechargeable lead-acid battery, 12 VAC wall-mount transformer and a NEMA 4X enclosure.

Figure 9-1 AC-Powered (“Configuration-2”) Unit Assembly

9.2 Unpacking, Damage reports, Item List

Upon receipt, inspect the CNI for any potential shipping damage. If any damage is detected that can be attributed to the way the package was handled, then a claim should be filed with the shipping agent as quickly as possible. A typical ac-powered CNI is provided with the following items:

• The Model GSM18, GSM20, CDMA18 or iDEN270 Cellular Network Interface card with Motorola g18, g20, c18 or iO270 cellular radio module

• “IMU-DC” firmware option

Never transport the unit with the lead-acid battery installed! A loose battery will damage the circuit boards.

Page 122: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com9-2

9-2

• Antenna • Power supply board. • 12-volt, 2.5 A-hr sealed lead-acid battery • 120 VAC to12 VAC wall-mount transformer. • Nema 4X enclosure • Manual 900349 (this document). Normally only one manual is included with each

shipment rather than with each unit. Additional manuals can be ordered separately or obtained in PDF file format upon request.

Note: The items listed above may vary depending on what was requested with the original purchase order. Refer to the shipping document or the purchase order for a precise record when inspecting the package contents. 9.3 Unit Assembly Dimensions

Figure 9-2

Enclosure Dimensions

Page 123: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

9-3 9-3

9.4 Electrical Wiring Diagram

Figure 9-3 Electrical Wiring Diagram

Page 124: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com9-4 9-4

9.5 Power Supply Board

Figure 9-4

1001-0308-001 Charger Board

Figure 9-5

1001-0316-001 Charger Board There is one of two power supply boards used depending upon the age of the unit. The primary input source for the power supply board is 12 VAC at 50-60 Hz, typically provided by a 120 VAC-to-12 VAC wall-mount power transformer. The output of the transformer connects to the TB-1 terminal bock. A 2.5 amp “pico” fuse at location F1 protects this input. The power supply board provides four functions. First, the board provides a regulated, low current (100mA) +4.2V supply for the CNI board. It is the primary power source when the radio is not being used and maintains the processor circuits and memory.

Page 125: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

9-5

9-5

This supply appears on the J3 connector of the power supply board (J3-1 is positive and J3-2 is ground). It connects to the J3 connector on the CNI board (J3-4 is positive and J3-1 is ground). When the radio is powered up the CNI generates a logic high signal on its J6 connector that causes the power supply board to turn on a high-current supply (J6-3 is signal and J6-2 is ground). This logic signal is connected to the J3 connector on the power supply board (J3-5 is signal and J3-6 is ground). The 12V high-current output appears on the J2 connector of the power supply board (J2-1 & 4 are positive and J2-2 & 3 are ground). The supply is connected to the TB2 terminal block on the CNI board (Pin-1 is positive and Pin-2 is ground). This supply provides the high current demanded by the radio. This supply voltage is regulated down to +5V on the CNI board. The third function is to supply a constant 12.6V charging voltage for the lead acid battery, which is connected to the J1 connector (J1-2 is positive and J1-1 is ground). A 2.5 amp “pico” fuse at location F3 protects this input. Nominal charging voltage is 13.5V. Finally the board monitors the condition of the 12 VAC power and reports a power-fail alarm condition to the CNI when it fails. This is a logic low signal that appears on the J3 connector (J3-3 is signal and J3-4 is ground). It is connected to the J6 connector on the CNI board (J6-1 is signal and J6-2 is ground). The 1001-0316-001 board also provides a regulated 5V, 100 mA supply on the TB3 terminal block (Pins-1 & 3 are positive and Pins-2 & 4 are ground). This supply may not be used in some assemblies.

9.6 AC Mains Power Supply Connection Power to the CNI is provided by stepping-down the AC mains voltage of 120Vac to 12Vac with a transformer and using this voltage to source the power supply board. The power supply board then converts the 12VAC to multiple DC voltages that are used to run the CNI as well as maintaining a charge on the lead-acid backup battery.

WARNING Never apply 120VAC mains voltage directly to the supply board terminal

block. This will result in a blown fuse and likely damage to the circuit board components.

The transformer is mounted externally to the CNI and connects to the TB1 terminal block. See Figure 9-6 for an illustration of a typical transformer unit. It may be necessary to use an alternate transformer at sites where the AC mains voltage is different or to comply with the special safety requirements of a specific country.

Page 126: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com9-6

9-6

Figure 9-6 12VAC Transformer

9.7 Installing or Replacing the Rechargeable Battery A 12V, 2.5Ahr sealed lead acid battery provides backup power and supports the brief but heavy current requirements of the cellular radio during transmissions. The lead acid battery is shipped separately to prevent damage to the electronic components and to satisfy regional rules regarding the shipment of hazardous materials.

Figure 9-7 Installation of the rechargeable battery

Page 127: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

9-7 9-7

Once the battery is installed, locate the two-wire cable with the white connector that is plugged into “J1” on the power supply board. Follow these steps:

1) Unplug the white connector from the “J1” connector on the power supply board. Grasp and squeeze the ears on the connector, then pull out.

2) Connect the black wire to the negative (-) terminal on the battery. 3) Connect the red wire to the positive (+) terminal on the battery.

9.8 External Antenna Kit Every CNI enclosure has been pre-drilled with a 1/4" diameter hole at the upper left-hand side of the enclosure wall or on the door. It is necessary to push out the small black hole plug and clean away any residual silicon sealant. As shown back in Figure 2-14 the SMA female end of the cable is then pressed through the enclosure wall and fastened into place using the provided washer and nut. When securing the antenna onto the SMA connector, ensure that the fitting is tightened sufficiently by hand (tools are not required), and that the antenna is vertically orientated. The opposite end of the cable with the MMCX connector end is pressed onto the mating connector of the Motorola cellular radio. 9.9 TAMPER Alarm The TAMPER alarm input has been pre-wired with a magnetic switch that activates when the door of the enclosure opens. The switch can be disconnected and the TAMPER input can be used for another purpose if desired. This is a Form-B (normally closed) input that will respond when the switch opens. 9.10 Low Battery Alarms The “Power Fail” alarm input has been pre-wired to accept a battery status signal from the power supply board. An AC-OFF alarm will be reported if the ac power has failed for more than 5 minutes. After an AC-OFF alarm is reported an AC-ON alarm will be reported when the ac power has been restored for longer than 5 minutes. 9.11 Notes About Battery Life Lead-acid battery life expectancy is 2-4 years. As with automotive batteries, temperature plays a key role in determining how long the battery will survive. Charge and discharge cycles are also important, and this will depend upon how the unit is configured. If the CNI makes frequent calls, the long-term life of the lead-acid battery will decrease.

Page 128: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com9-8

9-8

Check the voltage of the lead acid battery while it is in service. A fully charged battery should measure above 12V while in standby mode. If the voltage drops below 10V during a cellular call, the lead acid battery may need to be replaced. If it appears that the power supply is not performing properly, check the fuses at locations F1 and F3 on the power supply board. Replacement fuses are available from Mercury.

Page 129: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

10-1

10-1

10 Solar-Powered Unit Assembly

10.1 Description The solar-powered CNI consists of the CNI board, a power supply board, a rechargeable lead-acid battery, an optional solar panel (for charging the lead-acid battery) and a NEMA 4X enclosure.

Figure 10-1 Solar Powered Unit Assembly

10.2 Unpacking, Damage reports, Item List

Upon receipt, inspect the unit for any potential shipping damage. If any damage is detected that can be attributed to the way the package was handled, then a claim should be filed with the shipping agent as quickly as possible.

Never transport the unit with the lead-acid battery installed! A loose battery will damage the circuit boards.

Page 130: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com10-2

10-2

A typical ac-powered CNI is provided with the following items:

• The Model GSM18, GSM20, CDMA18 or iDEN270 Cellular Network Interface card with Motorola g18, g20, c18 or iO270 cellular radio module

• “IMU-DC” firmware option • Antenna • Power supply board. • 12-volt, 2.5 A-hr sealed lead-acid battery • Optional 12V solar panel • Nema 4X enclosure • Manual 900349 (this document). Normally only one manual is included with each

shipment rather than with each unit. Additional manuals can be ordered separately or obtained in PDF file format upon request.

Note: The items listed above may vary depending on what was requested with the original purchase order. Refer to the shipping document or the purchase order for a precise record when inspecting the package contents. 10.3 Unit Assembly Dimensions

Figure 10-2

Unit Assembly Dimensions

Page 131: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

10-3

10-3

10.4 Electrical Wiring Diagram

Figure 10-3 Electrical Wiring Diagram

10.5 Solar Power Supply Board

Figure 10-4

Solar Power Supply Board The solar power supply board, when connected to an adequate 12V solar panel, maintains a 13.6 V charge on the lead acid battery. The circuit is designed to prevent

Page 132: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com10-4

10-4

overcharging of the battery. The solar panel connects to the TB1 connector (Pin-1 is positive and Pin-2 is ground). The lead acid battery is connected to the J1 connector (J1-2 is positive and J1-1 is ground). A 4-amp fuse (F1) protects the solar panel and the charging circuits. Another 4-amp fuse (F2) protects the battery, power supply and CNI board. These fuses can be replaced. The board provides a regulated, low current (100mA) +4.2V supply for the CNI board. It is the primary power source when the radio is not being used and maintains the processor circuits and memory. This supply appears on the J3 connector of the power supply board (J3-1 is positive and J3-2 is ground). It connects to the J3 connector on the CNI board (J3-4 is positive and J3-1 is ground). When the radio is powered up the CNI generates a logic high signal on its J6 connector that causes the power supply board to turn on a high-current supply (J6-3 is signal and J6-2 is ground). This logic signal is connected to the J3 connector on the power supply board (J3-5 is signal and J3-6 is ground). The 12V high-current output appears on the J2 connector of the power supply board (J2-1 & 4 are positive and J2-2 & 3 are ground). The supply is connected to the TB2 terminal block on the CNI board (Pin-1 is positive and Pin-2 is ground). This supply provides the high current demanded by the radio. This supply voltage is regulated down to +5V on the CNI board. The board monitors the condition of the lead-acid battery and reports a low-battery condition to the CNI when the battery voltage reaches approximately 11.5V. This is a logic low signal that appears on the J3 connector (J3-3 is signal and J3-4 is ground). It is connected to the J6 connector on the CNI board (J6-1 is signal and J6-2 is ground). The board also provides a regulated 5V, 100 mA supply on the TB2 terminal block (Pins-1 & 3 are positive and Pins-2 & 4 are ground). This supply may not be used in some assemblies 10.6 Solar Panel Installation The solar panel and lead-acid battery are sized according to the geographical location of the CNI, average weather conditions and the expected call schedule. 10.6.1 Setting the Proper Solar Panel Tilt Angle Obtaining maximum power from the solar panel can only be achieved if it has been properly adjusted with the collector surface pointed towards the correction direction, and then adjusted for the tilt. Sophisticated systems exist with motorized drive mechanisms to track the sun as it travels from east to west, thereby yielding higher efficiencies. The cost and complexity of solar trackers prevents their use except in large arrays for power grid generation. Small standalone applications are best served with fixed angle mounts that are adjusted based on the latitude location. The solar panel should always face south for all locations north of the equator, and vice-versa if south of the equator. Solar panel tilt angle will vary depending upon the latitude

Page 133: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

10-5

10-5

of the installation location. The angles listed in Table 10-1 are calculated to provide optimum energy production during the winter months when solar radiation is at its weakest. A map is provided in Figure 10-5 to allow determination of the latitude for a given position in North America. Figure 10-7 shows how to apply the tilt angle obtained from Table 12-1 when adjusting the angle of the solar panel.

Latitude Tilt Angle 15º 15º 20º 20º 25º 25º 30º 35º 35º 45º 40º 55º 45º 65º 50º 70º

Table 10-1

Latitude versus Tilt Angle

Figure 10-5

Latitude Map for North America

Measurement of the tilt angle can be accomplished with a combination square utilizing a protractor head attachment. These tools are available from numerous sources including Starrett, Brown & Sharpe, Mahr, Mitutoyo, etc. A typical example is shown in Figure 10-6.

Page 134: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com10-6

10-6

Figure 10-6

Combination Square with Protractor Head

Figure 10-7

Solar Panel Tilt Adjustment 10.6.2 Selecting the Appropriate Gauge Power Cable Wiring from the solar panel to the solar power board is a simple matter of observing the correct polarity of the wires and selecting the proper wire. A minimum of 18AWG wire should be used to prevent excessive resistance losses in the cable. See Table 10-2 for a list of wire gauge vs. resistance loss. If the cable jacket of the wire is not rated for outdoor installation and ultraviolet light exposure, then it may be necessary to route the wires through a conduit.

Page 135: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

10-7

10-7

Wire Gage Diameter (mils) Ohms per 1000 feet 12 80.8 1.588 13 72.0 2.003 14 64.1 2.525 15 57.1 3.184 16 50.8 4.016 17 45.3 5.064 18 40.3 6.385 19 35.9 8.051 20 32.0 10.15 21 28.5 12.80 22 25.4 16.14 23 22.6 20.36 24 20.1 25.67 25 17.9 32.37 26 15.9 40.81 27 14.2 51.47 28 12.6 64.90

Table 10-2

Resistance of Wire

Page 136: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com10-8 10-8

10.6.3 Routing the Solar Panel’s Cable to the Power Supply Board Be sure to observe the polarity at each end of the cable. Loosen the nut on the right-hand cable gland. Route the cable through the gland, then through the right-hand rubber grommet attached to the battery shelf. Attach the cable to the TB1 terminal block on the power supply board. Then tighten the nut on the cable gland until it securely grabs the cable. There is a rubber insert in the shroud that compresses around the cables and seals the unit from water and insects.

Figure 10-8 Routing the Solar Panel Cable to the Power Supply Board

Page 137: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

10-9 10-9

10.7 Routing the External Device Cables to the CNI

Use the left-hand cable gland to route all data and alarm inputs to the CNI’s terminal block, as shown in Figure 10-9. Once the cables are routed through the gland tighten the shroud in the clockwise direction. There is a rubber insert in the shroud that compresses around the cables and seals the unit from water and insects.

Figure 10-9 Routing the External Device Cables to the CNI Board

10.8 External Antenna Kit Every CNI enclosure has been pre-drilled with a 1/4" diameter hole at the upper left-hand side of the enclosure wall or on the door. It is necessary to push out the small black hole plug and clean away any residual silicon sealant. As shown back in Figure 2-14 the SMA female end of the cable is then pressed through the enclosure wall and fastened into place using the provided washer and nut. When securing the antenna onto the SMA connector, ensure that the fitting is tightened sufficiently by hand (tools are not required), and that the antenna is vertically orientated. The opposite end of the cable with the MMCX connector end is pressed onto the mating connector of the Motorola cellular radio.

Page 138: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com10-10

10-10

10.9 TAMPER Alarm The TAMPER alarm input has been pre-wired with a magnetic switch that activates when the door of the enclosure opens. The switch can be disconnected and the TAMPER input can be used for another purpose if desired. This is a Form-B (normally closed) input that will respond when the switch opens. 10.10 Low Battery Alarms The “Power Fail” alarm input has been pre-wired to accept a battery status signal from the power supply board. An AC-OFF alarm will be reported if the lantern battery’s voltage falls below 11.5V for more than 5 minutes. After an AC-OFF alarm is reported an AC-ON alarm will be reported when the lantern battery’s voltage exceeds 11.5V for longer than 5 minutes. The description of these alarms can be changed in DC-2009 to be more meaningful, such as “Low Battery” and “Battery OK”. 10.11 Notes About Battery Life Lead-acid battery life expectancy is 2-4 years. As with automotive batteries, temperature plays a key role in determining how long the battery will survive. Charge and discharge cycles are also important, and this will depend upon how the unit is configured. If the CNI makes frequent calls, the long-term life of the lead-acid battery will decrease. Check the voltage of the lead acid battery while it is in service. A fully charged battery should measure above 12V while in standby mode. If the voltage drops below 11.5V during a cellular call, the lead acid battery may need to be replaced. Disconnect the solar panel and measure its output in full sunlight. The open-circuit voltage of a 12V panel can be as high as 17 volts.

If it appears that the power supply is not performing properly, check the fuses at locations F1 and F1 on the power supply board. Replacement fuses are available from Mercury.

Page 139: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

11-1

11-1

11 Flat Pack Unit Assembly

11.1 Description The flat pack assembly consists of the CNI board and other optional components mounted in a compact outdoor enclosure.

Figure 11-1

Flat Pack Interior View

Page 140: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com11-2

11-2

11.2 Enclosure Dimensions

Figure 11-2

Flat Pack Enclosure External Dimensions

Page 141: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

11-3

11-3

Figure 11-3

Flat Pack Enclosure Mounting Hole Locations and Sizes

Page 142: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com11-4

11-4

Figure 11-4 Flat Pack Enclosure Assembly

Page 143: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

11-5

11-5

11.3 Electrical Wiring Diagram

Figure 11-5 Electrical Wiring Diagram

Page 144: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com11-6 11-6

11.4 CALL Switch (Optional) Inside the enclosure is a magnetic reed switch mounted below the LED indicators. The switch can be activated by placing a strong magnet below the LED window on the outside of the enclosure. When this switch is activated the unit will call in to the data collection system and will report a “MAG SWITCH” alarm.

Figure 11-6 Location of the Magnetic CALL Switch

11.5 Dual Port Multiplexer (Optional) An optional board called the Dual Port Multiplexer (“MUX”) allows two serial devices to be connected to the CNI board. See Chapter-2 for more information about this board. 11.6 Backup Battery Pack (Optional) When main power is removed from the TB2 terminal block the CNI will lose all accumulated data. An optional backup battery pack is available that contains 3 “AA” lithium batteries. This pack will not only preserve the data and time-keeping but it will

11-7

allow the unit to continue to count pulses, respond to alarms and pages and call in when needed. Due to the power requirements of the cellular radio we only recommend the use of

Energizer e2 (L91) lithium batteries, which are available from most retailers. We cannot guarantee that alkaline batteries will be able to support the load and

their use may cause the board to reset, which will result in loss of data. If the CNI has been configured to only originate calls then the battery pack will support in excess of 100 calls. For example if the unit is configured to call in twice each day you can expect the batteries to last nearly 50 days without main power present. There is no drain from the batteries when main power is present, in which case the L91 lithium batteries can last up to 10 years. If the CNI has been configured to respond to voice or SMS pages or answer CSD data calls then the radio must remain powered up at all times. You can expect about 12 hours of continuous battery operation in this mode as long as the unit does not make too many calls. By using the Main Power Failure Detector Module (next discussion) the CNI will enter an emergency low-power conservation mode until main power is restored. 11.7 Main Power Failure Detector Module (Optional) When main power is removed from the TB2 terminal block the CNI will lose all accumulated data unless the optional backup battery pack is used (see previous discussion). If the CNI has been configured to respond to voice or SMS pages or answer CSD data calls then the radio must remain powered up at all times. You can expect about 12 continuous hours of operation in this mode as long as the unit does not make too many calls. But by using the Main Power Failure Detector Module the CNI will enter an emergency low-power conservation mode until main power is restored. The Main Power Failure Detector Module alerts the CNI when the main power has been lost for more than 5 minutes and again when the power has been restored for longer than 5 minutes. In the standard configuration the module is connected to the CNI’s “Power Fail” alarm input on the J6 connector. Here is what happens:

1) If the main power has failed for longer than 5 minutes the CNI will log an “AC-OFF” alarm. If the unit has been configured to originate calls it will attempt to call in and report it to the central computer. For this to work you must enable the “AC-OFF” alarm in the DC-2009 data collection program (see Chapter-5). If the call fails it will try again at a later time. That time is defined as either the “Primary Call Retry Rate” or “Secondary Call Retry Rate” depending upon how many attempts have been made so far.

2) If the unit has been configured to answer CSD data calls, receive SMS or voice

pages or maintain a permanent IP (Internet) connection, those modes are temporarily cancelled.

3) The radio will be powered down and the CNI will enter a low-power sleep mode.

Page 145: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

11-7

11-7

allow the unit to continue to count pulses, respond to alarms and pages and call in when needed. Due to the power requirements of the cellular radio we only recommend the use of

Energizer e2 (L91) lithium batteries, which are available from most retailers. We cannot guarantee that alkaline batteries will be able to support the load and

their use may cause the board to reset, which will result in loss of data. If the CNI has been configured to only originate calls then the battery pack will support in excess of 100 calls. For example if the unit is configured to call in twice each day you can expect the batteries to last nearly 50 days without main power present. There is no drain from the batteries when main power is present, in which case the L91 lithium batteries can last up to 10 years. If the CNI has been configured to respond to voice or SMS pages or answer CSD data calls then the radio must remain powered up at all times. You can expect about 12 hours of continuous battery operation in this mode as long as the unit does not make too many calls. By using the Main Power Failure Detector Module (next discussion) the CNI will enter an emergency low-power conservation mode until main power is restored. 11.7 Main Power Failure Detector Module (Optional) When main power is removed from the TB2 terminal block the CNI will lose all accumulated data unless the optional backup battery pack is used (see previous discussion). If the CNI has been configured to respond to voice or SMS pages or answer CSD data calls then the radio must remain powered up at all times. You can expect about 12 continuous hours of operation in this mode as long as the unit does not make too many calls. But by using the Main Power Failure Detector Module the CNI will enter an emergency low-power conservation mode until main power is restored. The Main Power Failure Detector Module alerts the CNI when the main power has been lost for more than 5 minutes and again when the power has been restored for longer than 5 minutes. In the standard configuration the module is connected to the CNI’s “Power Fail” alarm input on the J6 connector. Here is what happens:

1) If the main power has failed for longer than 5 minutes the CNI will log an “AC-OFF” alarm. If the unit has been configured to originate calls it will attempt to call in and report it to the central computer. For this to work you must enable the “AC-OFF” alarm in the DC-2009 data collection program (see Chapter-5). If the call fails it will try again at a later time. That time is defined as either the “Primary Call Retry Rate” or “Secondary Call Retry Rate” depending upon how many attempts have been made so far.

2) If the unit has been configured to answer CSD data calls, receive SMS or voice

pages or maintain a permanent IP (Internet) connection, those modes are temporarily cancelled.

3) The radio will be powered down and the CNI will enter a low-power sleep mode.

Page 146: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com11-8

11-8

During this time all LEDs are turned off.

4) The CNI will still count pulses and respond to alarm conditions. It will wake up and place calls under those alarm conditions. It will return to sleep mode after each call is placed. However the CNI will not retry calls that are unsuccessful except for the call to report the “AC-OFF” alarm. All alarms that were not reported will be reported the next time the CNI is able to contact the system.

5) In this mode the CNI does not initiate calls based on the call schedule that was

given to it by DC-2009.

6) When the main power has been restored for longer than 5 minutes the CNI will log an “AC-ON” alarm. If the unit has been configured to originate calls it will attempt to call in and report it to the central computer. For this to work you must enable the “AC-ON” alarm in the DC-2009 data collection program (see Chapter-5).

7) The CNI will now restore itself to the conditions that existed prior to the power

failure.

Page 147: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

12-1 12-9

12 SAFETY, HAZARDOUS AREAS, ESD PRECAUTIONS

12.1 Safety

This product contains a radio-frequency transmitter, Motorola Model g18, FCC ID # IHDT6AC1,

Motorola Model g20, FCC ID # IHDT56DB1, Motorola Model g24, FCC ID # IHDT56FV2

Motorola Model c18, FCC ID # IHDT56CW1 or Motorola Model iO270, FCC ID # AZ489FT7011

The combined cable loss and antenna gain must not exceed +6.8 dBi (850

band), +1.9 dBi (900 band), +7.7 dBi (1800 band) and +2.2 dBi (1900 band). Total system output must not exceed 2.0W EIRP in the 1900 band in order to comply with the EIRP limit of 24.232. The antenna installation must provide a minimum separation distance of 20cm (8”) from users and nearby persons and

must not be collocated or operating in conjunction with any other antenna or transmitter.

See Chapter-12 for more safety information.

Hazardous Area Classification At the time of this publication no hazardous area safety approvals have been issued for this product. It is therefore necessary to ensure that the product is only installed at locations that are classified as ‘safe area’ sites. Safety barriers must be utilized if it becomes necessary to route any cables into a hazardous area boundary. Refer to the U.S. National Electrical Code (NEC) book, article 510, as well as any relevant local ordnance for guidance with hazardous area wiring. It is the responsibility of the user to ensure compliance with regulations regarding hazardous area locations. This may require the site to be inspected by a certified electrician to maintain full compliance.

Page 148: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com12-2

12-10

12.2 ESD Handling Precautions Any electronics device contains components sensitive to ESD (electrostatic discharge). For example people experience up to 35kV ESD, typically while walking on a carpet in low humidity environments. In the same manner many electronic components can be damaged by less than 1000 volts of ESD. For this reason you must observe the following handling precautions when servicing this equipment:

• Always wear a conductive wrist strap. • Eliminate static generators (plastics, styrofoam, and so on) in the work area. • Remove nylon or polyester jackets, roll up long sleeves, and remove or tie back

loose hanging neckties, jewelry, and long hair. • Store and transport all static sensitive components in ESD protective containers. • Disconnect all power from the unit before ESD sensitive components are

removed or inserted, unless noted. • Use a static safeguarded workstation, which can be set up by using an anti-static

kit (Motorola part number 0180386A82). This kit includes a writes strap, two ground cords, a static control tablemat, and a static control floor mat. The Motorola part number for a replacement wrist strap that connects to the tablemat is 4280385A59.

• When anti-static facilities are unavailable, use the following technique to minimize the chance of damaging the equipment:

o Let the static sensitive component rest on a conductive surface when you are not holding it.

o When setting down or picking up the static sensitive component, make skin contact with a conductive work surface first and maintain this contact while handling the component.

o If possible, maintain relative humidity of 70-75% in development labs and service shops.

Page 149: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

13-1 13-1

13 TECHNICAL SPECIFICATIONS GENERAL Model: GSM18, GSM20, CDMA18 or iDEN270 Cellular Network

Interface with “IMU-DC” firmware option Input Voltage Range (TB2): 9 to 28 Vdc Input Current Requirements: 800 milliamps minimum.

For the GSM18 or GSM20 average current is around 300 mA but peak currents can be as high as 1.8 amps for a duration of 0.5 milliseconds every 4.5 milliseconds. For the iDEN270 average current is around 250 mA but peak currents can be as high as 1.2 amps for a duration of 15 milliseconds every 90 milliseconds. Maximum current draw for the CDMA18 is about 800 milliamps while transmitting.

Standby Voltage Range (J3): 4.0 to 5.5 Vdc. Minimum current requirements are the

same as those listed for TB2. For Rev-A, B or C boards this input must be diode-blocked when using a main supply at TB2. See Chapter-2.

Sleep current (J3): < 800 uA, originate mode only. Main oscillator frequency: 9.8304 MHz. Number of inputs: 2 Form-A alarm inputs, 1 Form-B alarm input 2 Form-A alarm or pulse data inputs Wetting current per input: 175uA nominal. Serial Port: Output levels on TX, DCD and DSR: ±9V max. Input levels on RX and DTR: ±15V max. Baud rate: 300 to 38400 (user-selectable) Weight (board only): 3.8 oz (108 grams) Board Dimensions: 5.65” x 4.57” x 0.726” (143.5mm x 116mm x 18.4mm) Operating temperature range: -22° to +140° Fahrenheit (-30° to +60° Celsius)

Page 150: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com13-2 13-2

CELLULAR RADIO INFORMATION Cellular Radio (GSM18): Motorola Model g18 Tri-Band GSM GPRS

FCC ID# IHDT6AC1 Mercury Stock Number 1015-0184-001 Cellular Radio (GSM20): Motorola Model g20 Dual-Band GSM GPRS

FCC ID# IHDT56DB1 Mercury Stock Number 1015-0199-001 (850 / 1900 MHz) Mercury Stock Number 1015-0201-001 (900 / 1800 MHz) or Motorola g24 Quad-Band GSM GPRS FCC ID # IHDT56FV2 Mercury Stock Number 1015-0211-001 Cellular Radio (CDMA18): Motorola Model c18 Dual-Band CDMA 1XRTT

FCC ID# IHDT56CW1 Mercury Stock Number 1015-0198-001 Cellular Radio (iDen270): Motorola Model iO270 Dual-Band iDEN

FCC ID# AZ489FT7011 Mercury Stock Number 1015-0210-001 Receive Frequencies: GSM20, CDMA18 824-849 MHz

GSM20, GSM18 880-915 MHz GSM20, GSM18 1805-1880 MHz

GSM20, GSM18, CDMA18 1930-1990 MHz iDEN270 (iDEN 800) 851-870 MHz iDEN270 (iDEN 900) 935-941 MHz

Transmit Frequencies: GSM20, CDMA18 869-894 MHz

GSM20, GSM18 880-915 MHz GSM20, GSM18 1710-1785 MHz GSM20, GSM18, CDMA18 1850-1910 MHz iDEN270 (iDEN 800) 806-825 MHz iDEN270 (iDEN 900) 896-902 MHz

ANTENNA INFORMATION Antenna Connector: MMCX Jack (female), 50 ohm impedance. (GSM18, GSM20, CDMA18) Antenna Connector: U.FL Jack (male), 50 ohm impedance. (iDEN270) Antenna (internal rigid): 1850 – 1990 MHz, Mercury Stock #1008-0012B-001 (GSM18, GSM20, CDMA18) Antenna (internal quad-band):824 – 894, 890 – 960, 1710 – 1880, 1850 – 1990 MHz (GSM18, GSM20, CDMA18) Mercury Stock #1015-0208-001

Page 151: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

13-3 13-3

Antenna (internal quad-band):824 – 894, 890 – 960, 1710 – 1880, 1850 – 1990 MHz (iDEN270) Mercury Stock #1015-0209-001 Antenna (external kit): 1850 – 1990 MHz, Mercury Stock #1014-0042-003 10.5” (25.4 cm) cable 1710 – 1880 MHz, Mercury Stock # 1014-0042-002 (GSM18, GSM20, CDMA18) 890 – 960 MHz, Mercury Stock # 1014-0042-001 824 – 894 MHz, Mercury Stock # 1014-0042-004 Antenna (external kit): 824 – 894 MHz, Mercury Stock # 1014-0054-001 11.8” (30 cm) cable 890 – 960 MHz, Mercury Stock # 1014-0054-002 (iDEN270) Antenna cable only: 42” (106 cm) Mercury Stock # 1002-0303-005 (GSM18, GSM20, CDMA18) SMA female bulkhead one end, MMCX other end (see Figure 2-14) Antenna cable only: 11.8” (30 cm) Mercury Stock # 6145-0227 (iDEN270) SMA female bulkhead one end, U.FL other end (see Figure 2-14) ADDITIONAL SPECIFICATIONS FOR BATTERY-POWERED ASSEMBLIES

Battery Types: Lead acid: 12V, 2.5 AHr, Yuasa / Genesis brand

NP2.3-12 FR or equivalent (Mercury 6135-0049) Lantern battery: 6V, Energizer brand 521 or equivalent. Fuse ratings: 2.5 amp “pico” fuses at positions F2 & F3. Fuse type: 2.5 amp. Littelfuse 251-02.5 or equivalent

(Mercury Stock #5920-0053) Weight: Without lantern battery: 7.2 pounds (3.26 Kg) Lantern battery installed: 11.4 pounds (5.17 Kg) Dimensions: 11.5” x 9.3” x 5.35” (29.2cm x 23.6cm x 13.6cm) ADDITIONAL SPECIFICATIONS FOR AC-POWERED (CONFIG-1) ASSEMBLIES

Input Voltage: Selectable 90 to 140 volts (115 VAC setting) or 180-280

volts (230 VAC setting). Line frequency: 50 or 60 Hz. AC burden: 6 watts with radio in the receive mode. Fuse ratings: 0.5A (500 mA) slow-blow fuse at position F1. Fuse type: 5x20mm. Littelfuse 217-500 or equivalent

(Mercury stock no. 5920-0146)

Page 152: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com13-4 13-4

Backup Battery Type: Lithium ‘C’ Cell: 3.6V, 5.5 AHr, Saft brand LSH14

or equivalent (Mercury 6135-0091), two required.

Weight: Without lithium batteries: 3.6 pounds (1.6 Kg) With lithium batteries: 3.75 pounds (1.7 Kg) Dimensions: 6.91” x 8.50” x 4.25” (17.6 cm x 21.6 cm x 10.8 cm)

ADDITIONAL SPECIFICATIONS FOR AC-POWERED (CONFIG-2) ASSEMBLIES

Input Voltage: 12 VAC, 50-60 Hertz Battery: Lead acid: 12V, 2.5 AHr, Yuasa / Genesis brand

NP2.3-12 FR or equivalent (Mercury 6135-0049)

Fuse ratings: 2.5 amp “pico” fuses at positions F2 & F3. Fuse type: 2.5 amp. Littelfuse 251-02.5 or equivalent

(Mercury Stock #5920-0053) Weight: 7.2 pounds (3.26 Kg) Dimensions: 9.3” x 11.3” x 5.5” (23.6cm x 28.7cm x 14.0cm)

ADDITIONAL SPECIFICATIONS FOR SOLAR-POWERED ASSEMBLIES

Solar Panel: 10W, [email protected], UniSolar US-11 or equivalent

(Mercury Stock # 6135-0095)

Note: Solar panel size and wattage may vary depending on application.

Battery Type: Sealed lead acid, 12V, 12 Ahr, Leoch DJW12-12

or equivalent (Mercury Stock no. 6135-0093) Note: Battery capacity may vary depending on application.

Fuse ratings: 4.0 amp “pico” fuses at positions F1 & F2. Fuse type: 5x20mm, 4 amp. Littelfuse 251-004 or equivalent

(Mercury Stock no. 5920-0063)

Weight (without battery): 5.1 pounds (2.3 Kg) Weight (with battery): 13.7 pounds (6.2 Kg) (Leoch DJW12-12) Dimensions : 11.5” x 9.3” x 5.35” (29.2 cm x 23.6 cm x 13.6 cm)

Page 153: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

13-5

13-5

ADDITIONAL SPECIFICATIONS FOR FLAT-PACK ASSEMBLIES

Enclosure: Grey ABS 94V-2 polycarbonate (Bayer Makrolon 2807). Cable Glands: Material: 6/6 nylon with TPE rubber insert Rating: IP68 (cable gland only) Wrench flats distance: 15.0mm (0.59 inch) Entry hole diameter: 2.90mm (0.114 inch) minimum cable 6.35mm (0.250 inch) maximum cable Standard AC power: Mercury Stock #5950-0125B-001, 120VAC in, 12Vdc Adapter (optional) out@1000 mA. Backup Battery Pack: Mercury Stock # 6135-0105-001 (optional) Recommended Batteries: Energizer e2 (L91) lithium (3 required) Main Power Failure Mercury Stock # 1008-0020-001 Detection Module: Draws 11 mA from a 12V dc main power supply. (optional) Weight (without batteries): 1.12 pounds (0.51 Kg) Weight (with batteries): 1.24 pounds (0.56 Kg) (3 Energizer L91 lithium)

Page 154: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

www.honeywell.com14-1

14-1

14 ASCII-HEX-DECIMAL CONVERSION CHART

Page 155: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

15-1

15-1

15 WARRANTY INFORMATION Seller warrants to Purchaser only the products to be free from defects in material and workmanship for a period of twelve (12) months from the date of delivery. SELLER MAKES NO OTHER REPRESENTATIONS OR WARRANTIES TO PURCHASER REGARDING THE PRODUCTS AND EXPRESSLY DISCLAIMS ALL OTHER IMPLIED OR EXPRESS WARRANTIES, INCLUDING ALL WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Seller’s Product warranty does not apply to any Product to the extent it has been subject to (1) other than normal wear and tear, or (2) improper installation, alteration, modification, or repair, tampering, negligence, abuse or accident, or (3) improper storage or shipment. SELLER’S LIABILITY IS LIMITED TO REPAIR OR REPLACEMENT, AT SELLER’S OPTION, OF ANY DEFECTIVE PRODUCT. Seller will repair or replace, at its option, products which upon inspection it finds to be defective, based on claims made in writing to Seller within a reasonable time after discovery. products alleged to be defective must be returned, freight prepaid, within thirty (30) days to Seller with the return authorization number, obtained from Seller, clearly marked on the outside of the return container for repair or replacement by Seller. THE ABOVE WARRANTY SHALL CONSTITUTE PURCHASER’S EXCLUSIVE REMEDY WITH RESPECT TO THE PRODUCTS FURNISHED HEREUNDER. IN NO EVENT SHALL SELLER BE LIABLE OR RESPONSIBLE TO PURCHASER OR ANY OTHER PERSON FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL LOSSES OR DAMAGES, WHETHER BASED ON CONTRACT, TORT, STRICT LIABILITY OR OTHER THEORY OF LAW, EVEN IF SELLER SHALL HAVE BEEN ADVISED OF THE POSSIBILITY OF ANY SUCH LOSS OR DAMAGES, ALL SUCH DAMAGES AND CLAIMS ARE HEREBY SPECIFICALLY DISCLAIMED. IN NO EVENT SHALL SELLER’S LIABILITY EXCEED THE PURCHASE PRICE OF THE PRODUCT.

Returns Procedure If it has been determined through troubleshooting that the problem cannot be resolved without returning the equipment for repair, then a return authorization (RA) number will need to be obtained. Please call 1-800-327-8559 or 1-321-259-9700 to contact the repairs department for obtaining the RA number as well as the return form document that should be filled out. When filling out the repair return form, it is beneficial to provide a description of the problem with as much detail as is necessary to fully characterize the symptom(s). This will assist our technicians in being able to narrow in on the problem, and reduces the possibility that a unit will be returned to the customer with “no problem found”. Intermittent type problems can be especially difficult to troubleshoot without a detailed description of the symptoms.

Page 156: Cellular Network Interface (CNI) - Mercury Instruments · Honeywell Process Solutions Cellular Network Interface (CNI) Models GSM18, GSM20, CDMA18, iDEN270 with Industrial Metering

MNL-CNI-900349-1November 2010 © 2010 Honeywell

Find Out More:To learn more aboutMercury Instruments products, contact your Honeywell Process Solutions representative, visit www.mercuryinstruments.com or call 513-272-1111. Automation and Control SolutionsHoneywell Process Solutions3940 Virginia Ave.Cincinnati, OH 45227513-272-1111 www.honeywell.com