400C Issue 2May 2004
Plasterboard Ceiling Systems
2
Fire-rated Ceiling Systems
3
Fire-rated Ceiling Systems
Plasterboard Ceiling Systems
Contents
Fire-rated Ceiling SystemsStandard Ceilings Design ............................... 3-7
Introduction.....................................................3Fire Ratings .....................................................3Systems Mass.................................................3Decoration.......................................................3General Construction Details.........................4Materials...................................................... 4-5Installation.......................................................6Backblocking ...................................................7
System Selection ............................................8-18Standard Construction .................................19-22Cable and Loaded Penetrations........................23Pipe Penetrations...............................................24Ceilings to a Radius...........................................25Change of Pitch..................................................26Bulkheads......................................................27-28Light Recess .......................................................29Access Hatch ................................................ 30-31Beam Protection .......................................... 32-34Joints ..................................................................35Perimeter Details ......................................... 36-38
Non Fire-rated Ceiling SystemsStandard Ceilings Design ........................... 39-43
Introduction...................................................39Fire Hazard Properties..................................39Systems Mass...............................................39Decoration.....................................................39General Construction Details.......................39Materials.................................................. 39-40Installation............................................... 40-41Backblocking ........................................... 42-43
System Selector.................................................44Standard Construction ................................ 45-47Perimeter and Bulkhead Details .......................48
QuietZone™ Ceiling SystemsIntroduction........................................................49Acoustic Ceiling Mount............................... 49-50
Installation ...............................................49Direct Fix ..................................................49Suspended ...............................................50Load Ratings ............................................50Performance.............................................50
Acoustic Selector ...............................................51Installation.................................................... 52-54
Quiet Ceilings ..........................................52Quieter Ceilings .......................................53Quietest Ceilings .....................................54
General InformationGuarantee............................................Back CoverTecASSIST Details ..............................Back CoverContact Details....................................Back Cover
2
Fire-rated Ceiling Systems
3
Fire-rated Ceiling Systems
IntroductionBoral Plasterboard Fire-rated Ceiling Systems have been designed to provide fire resistance ratings of FRL 30/30/30, FRL 60/60/60, FRL 90/90/90 and FRL 120/120/120. Systems are also available to provide 30, 60, 90 or 120 mins. resistance to incipient spread of fire.
Ceilings can be constructed under roofs of Tile, Aluminium or Steel Profiled Section fixed to battens on a steel or timber framework or under floors constructed of at least 12mm Plywood, Timber or Particle Board fixed to a steel or timber supporting frame.
Ceiling systems may be fixed as either a Direct Fixed System, Suspended System, or Direct Clipped (Furred) System.
Note:• Where illustrations in this manual show a
Suspended Ceiling System, a Direct Fixed or Furred System may also be used.
• These ceiling construction details are not suitable for external ceilings.
Construction Features• Ceiling can be curved to a minimum radius
of 6000mm.• Ceiling can be constructed to a pitch of up to
70 degrees from the Horizontal.• Ceiling systems can incorporate the
following approved features: Access Panels, Bulkheads, Light & Luminaire fittings, Plumbing Pipe penetrations, Power Cable penetrations, Loaded penetrations, Control Joints, Protection to Steel & Timber Beams, Changes in ceiling slope direction and a variety of Perimeter Details.
• Thermal or acoustic insulation (max. 3kg/m2) may be placed above ceiling.
Fire RatingsBoral Plasterboard FRL 30/30/30 Ceiling Systems: Appraised by the CSIRO Division of Building, Construction and Engineering and covered by fire opinion FCO-0568.
Boral Plasterboard FRL 60/60/60 Ceiling Systems: Appraised by the CSIRO Division of Building, Construction and Engineering and based on fire tests; SI 23, SI 736, SI 1761, SI 1891,TR 238(L),TR 336(L) and FSH-0597. These systems are covered and validated by fire opinion FCO-1658.
Boral Plasterboard FRL 90/90/90 Ceiling Systems: Appraised by the CSIRO Division of Building, Construction and Engineering and based on fire tests; SI 23, SI 710, SI 736, SI 1761 and SI 1891. These systems are covered and validated by fire opinion FCO-1856.
Standard Ceilings Design
Boral Plasterboard FRL 120/120/120 Ceiling Systems: Appraised by the CSIRO Division of Building, Construction and Engineering and based on fire tests; SI 23, SI 710, SI 736, SI 1761, SI 1891 and FSH-0597. These systems are covered and validated by fire opinions FCO-1856 andFCO-1658. For details of the FRL 120/120/120 system, please refer to Boral Plasterboard TecASSIST or TecSYS - a comprehensive technical catalogue on CD-ROM (see back cover).
Early Fire Hazard PropertiesBoral Plasterboard Firestop, tested for Early Fire Hazard Properties in accordance with Australian Standard 1530.3 - 1989, recorded the following results:
Ignitability (0-20) - 13Spread of Flame (0-10) - 0Heat Evolved (0-10) - 1Smoke Developed (0-10) - 2
Ceiling Systems Mass Calculations
Component Mass• One layer of 16mm Boral Firestop
Plasterboard has a mass of approximately 13kg/m2;
• One layer of 13mm Boral Firestop Plasterboard has a mass of approximately 10.5kg/m2;
• Rondo Furring Channel Part No. 129 has a mass of approximately 0.5kg/m;
• Rondo Top Cross Rail Part No. 128 has a mass of approximately 0.7kg/m.
Systems MassThe following table shows mass calculations based on the above approximations:
DecorationThe ceiling system is flush jointed to provide a smooth, continuous surface ideal for all forms of decoration. Care must be taken to apply paint or other finishes strictly in accordance with the manufacturer’s instructions.
PlasterboardLayers
PlasterboardMass
SuspensionSystem Mass*
1 x 16mm2 x 16mm2 x 13mm3 x 13mm1 x 13mm1 x 16mm3 x 16mm4 x 16mm
13kg/m2
26kg/m2
21kg/m2
31.5kg/m2
23.5kg/m2
39kg/m2
52kg/m2
15kg/m2
28kg/m2
23kg/m2
33.5kg/m2
25.5kg/m2
41kg/m2
54kg/m2
* The suspension system mass is approximate only and based on a Rondo steel suspension system with Top Cross Rails @ 1200mm centres, Furring Channels @ 600mm centres and an average drop.
4
Fire-rated Ceiling Systems
5
Fire-rated Ceiling Systems
Standard Ceilings Design
General Construction DetailsMovement joints should be put at building construction joint locations. Control joints should be spaced at not more than 12 metre max. centres in either direction (15 metre centres where there is perimeter relief). Refer to "Joints" for details.
Specifiers should be aware of the likelihood of frame movement due to structural, thermal and seasoning effects on direct fixed plasterboard ceilings. Where necessary specify a furred system to minimise the risk of ceiling damage due to these effects.
Caution:Boral Plasterboard ceiling systems are not designed to support the weight of maintenance personnel, additional plant or storage of goods.
Materials• 16mm or 13mm Boral Firestop Plasterboard
recessed edge.• Boral Plasterboard Jointing Compound
(as preferred from the Boral Plasterboard Jointing Compound range).
• Boral Plasterboard Cornice 55mm, 75mm & 90mm if required, applied using Boral Plasterboard Cornice Adhesive or Cornice Adhesive Mid Set.
• Perforated paper tape.• Approved fire-rated sealant for caulking
gaps at ceiling perimeters.• Boral Cornice Adhesive.• Screws and nails as specified.• Rivets (all steel).
Refer to Safety Data Sheets, available from Boral Plasterboard Sales Offices, or the container labelling, when handling relevant products.
All materials used in the construction of Boral Plasterboard ceiling systems must be carefully stored and protected on the construction site. Plasterboard is to be stacked flat and protected from moisture. Boral Firestop Plasterboard must not be used where it will be exposed to excessive moisture. In addition, damaged plasterboard sheets and accessory materials must not be used.
FastenersScrewsAll screws are to AS3566- 1988 corrosion class 1 and are defined as follows:
• Type S is a double start, needle point, bugle head gypsum screw for fixing to steel gauges of up to 0.80mm BMT.
• Type D is a double start, drill point, bugle head gypsum screw for fixing to steel gauges from 0.80mm to 2.00mm BMT.
• Type W is a single start, needle point, bugle head gypsum screw for fixing to hardwood and softwood framing. In some instances double start screws are permissible (refer to Boral Plasterboard for details).
• Type L is a single start, needle point, bugle head gypsum screw for fixing plasterboard to plasterboard.
Note that correct screw length is critical when fastening to resilient furring channel to avoid acoustic bridging.
NailsAlthough nail lengths specified are minimum, care should be taken when using longer nails to avoid bending in hardwoods or popping of plasterboard with unseasoned timber.
Fastener SelectionThe following tables show the correct selection of screws and nails for the construction of Boral Plasterboard ceiling systems.
Number of Layers of Plasterboardx Thickness
1 x 13mm1 x 16mm1 x 16mm
Min. 13mm Min. 16mm
Min. 2 x 16mm
Type L Screws for Fixing Plasterboard
A to B
10 - 8 x 32mm 10 - 8 x 38mm 6 - 8 x 50mm
Screws - Plasterboard to Plasterboard
Plasterboard A Plasterboard B
Screw identification is given as:(min. gauge) - (threads/inch ±1) x (min. length)
Timber Frame -Type W Screws
Number of Layers of
Plasterboardx Thickness
1 x 13mm1 x 16mm2 x 13mm2 x 16mm
6 - 9 x 32mm 6 - 9 x 40mm6 - 9 x 50mm6 - 9 x 60mm
Steel Frame -Type S or Type D Screws
1 x 13mm+ 1 x 16mm
6 - 18 x 25mm*6 - 18 x 30mm6 - 18 x 40mm6 - 18 x 45mm
Screws - Plasterboard to Ceiling Frame
3 x 16mm
6 - 9 x 50mm 6 - 18 x 40mm
8 - 8 x 75mm 8 - 15 x 60mmType S only
Screw identification is given as:(min. gauge) - (threads/inch ±1) x (min. length).
* For ease of construction with framing steel gauges of less than 0.8mm BMT, use 30mm minimum length screws.
7 - 16 x 50mmType S only
3 x 13mm 8 - 8 x 60mm
4
Fire-rated Ceiling Systems
5
Fire-rated Ceiling Systems
Standard Ceilings Design
Suspension BracketNo. 274
Suspension BracketNo. 247
Furring ChannelNo. 129
Top Cross RailNo. 128
JoinerNo. 139
Direct Fixing ClipNo. 226
Direct Fixing ClipNo. 394
Direct Fixing ClipNo. 237
Suspension RodNo.121
Suspension ClipNo. 2534
Corner BeadNo. P32
Control JointNo. P35
Wall TrimNo. DU05
Steel AngleNo. 554
Shadow Line TrimNo. P50
Rondo Fixing and Suspension ComponentsManufactured by Rondo Building Services Ltd. and marketed by Boral Plasterboard:
129 - Furring Channel128 - Top Cross Rail139 - Joiner to Top Cross Rail237, 226, 394 - Direct Fixing Clips247 or 274 - Suspension Bracket121 - Suspension RodDU05 - Wall Trim2534 - Adjustable Suspension ClipP32, P01 - External Corner Bead553 - All Steel Angle 35x35x0.75554 - All Steel Angle 50x50x0.75P35 - Rondo Control JointP50 - Shadow Line Trim
See illustrations below.
Smooth Shank Gold Passivated
Annular Ring Shank and
Uninail
Number of Layers of
Plasterboardx Thickness
1 x 13mm
1 x 16mm
40mm¹30mm²50mm¹50mm²65mm¹,²65mm¹,²
1 = Softwood 2 = Hardwood
30mm¹30mm²
Galvanised 2.8mm
Diameter
1 x 13mm+ 1 x 16mm
40mm¹30mm²50mm¹40mm²50mm¹,²65mm¹,²
75mm x 3.75¹,² 75mm x 3.75¹,²
Nails - Plasterboard to Timber Frame
2 x 13mm2 x 16mm3 x 13mm3 x 16mm
65mm¹,² 50mm¹,²
Fasteners (continued)
Rondo Fixing and Suspension Components
6
Fire-rated Ceiling Systems
7
Fire-rated Ceiling Systems
Standard Ceilings Design
Plasterboard Application for Systems using 1, 2 or 3 Layers of Plasterboard.
1. Fix Boral Firestop Plasterboard across the Furring Channel, Timber or Steel framing.
2. Butt (end) joints on the first layer (uppermost sheet) not formed on framing members should be back-blocked as described under "Back-blocking".
3. The first layer (uppermost) of Firestop plasterboard sheets are fastened at 200mm max. centres in the field of board and at 150mm max. centres on ends and edges (staggered).
4. Additional layers of Firestop plasterboard sheets are fixed in the same manner as the first layer but with joints staggered between layers min. 200mm.
5. Additional layer butt joints not formed on a framing member are screw laminated to the previous layer at 200mm max. centres.
6. Tape and finish face sheet with preferred Boral Plasterboard jointing system.
Plasterboard Application forFRL 120/120/120 Systems Using 4 Layers of Plasterboard.
1. Fix the upper two layers as in steps 1 to 5 above.
2. Fix Rondo P.N. 129 furring channels at 600mm centres to Rondo P.N. 237 clips @ 1200mm centres fixed through upper two layers and into the primary framing with min.12 x 60mm roofing screws.
3. Fix first of bottom two layers of Boral Firestop Plasterboard across the secondary furring channel framing at 200mm max. centres in the field of board and at 150mm max. centres on ends and edges (staggered).
4. Butt or end joints on this layer not formed on framing members should be back-blocked as described under "Back-blocking".
5. The second of the two bottom layers of Firestop plasterboard sheets is fixed in the same manner as the first layer but with joints staggered between layers min. 200mm.
6. Screw laminate bottom layer butt joints not formed on framing members at 200mm centres to previous layer with 10x38 Type L screws.
7. Tape and finish face sheet with preferred Boral Plasterboard jointing system.
InstallationCeiling systems may be constructed by fixing layers of 16mm and/or 13mm Boral Firestop Plasterboard in either, a Suspended, Direct Fixed or Direct Clipped (furred) system as per details under "Standard Construction".
Furring channel and framing supports to be taken to and provided within 50mm of ceiling perimeter - min 15mm end clearance to walls. Allowance should be made for an expansion gap at the rate of 3mm per 1 metre run in abutting Furring Channels and Top Cross Rails.
All permitted and approved fire-rated penetrations or features must be installed and caulked in accordance with the details provided in this manual.
Suspended SystemsCeiling framing and design to be in accordance with the requirements of A.S.2785.
• Attach suspension rods to suspension rod brackets that are anchored to structural framing or concrete soffit, at 1200mm maximum centres in each direction.
Note: Each suspension rod bracket fastening must be capable of supporting a weight of 143kg plus the self load of the system and pressure loads.
• Attach suspension clips to top cross rails, and fit suspension clips to rods. Adjust the rails to a true and level plane.
• Position furring channels at 600mm maximum centres and attach to top cross rails with a locking clip at each intersection.
• Join lengths of furring channel with furring channel joiners, ensuring the joins are staggered.
• Extra suspension components must be provided to support light fittings, bulkheads and other fixtures. Spans and spacings may be reduced if required.
Direct Clipped (Furred) SystemsPosition furring channels at 600mm maximum centres and attach channels to structural framing with direct fixing clips at 1200mm maximum centres, or to concrete soffit with anchor clips fastened to soffit at 1200mm maximum centres. Ensure that furring channels are fixed to a true and level plane. Spans and spacings may be reduced if required.
Direct Fixed SystemsWhere fixing direct to timber or steel framing without furring channel, framework should not exceed 600mm spacing. Spans and spacings may be reduced if required.
6
Fire-rated Ceiling Systems
7
Fire-rated Ceiling Systems
Standard Ceilings Design
Architectural SpecificationBoral Plasterboard Ceilings shown in the relevant drawings shall consist of materials supplied by Boral Plasterboard, fixed and finished in accordance with the instructions contained in Boral Plasterboard Technical Manuals and in TecSYS - a comprehensive technical catalogue on CD-ROM (see back page for details).
As drawings are updated from time to time, users are advised to check drawing currency before adopting the procedures and details noted thereon.
Back-blockingBack-blocking is a mandatory fixing requirement where specified in the Australian StandardAS/NZS 2589.1:1997.
Failure to provide back-blocking installed as per AS/NZS 2589.1:1997 may result in liability for any associated costs relating to maintenance and/or rectification caused by jointing defects.
Multiple LayersButt or end joints on the first layer (uppermost sheet) not formed on framing members must be dry back-blocked as follows:
• Cut back-blocking pieces from 16mm Boral Firestop Plasterboard to sizes no less than 200mm wide and in lengths that will fit between the framing members.
• Fix Boral Plasterboard ceiling sheet transverse to framing members, placing the back-blocks centrally along the full length of the sheet's edge.
• Fix ceiling sheet to back-blocks with10 x 38mm Type L screws at 200mm max. centres.
• Fix the next ceiling sheet and screw laminate to back blocks.
Back-blocking pieces of 16mmBoral Firestop Plasterboard min.200mm wide fixed with 10 x 38Type L screws @ 200mmmax. centres
Framing
Top layer of BoralFirestop Plasterboard
For single layer systems,back-blocks to be fixed withcornice adhesive and screws
Joints in other layersstaggered min. 200mmfrom previous layer
EQ
EQ
100mm min.
200mm min.
Laminate back-block toback face of ceiling with10 x 38 Type L screws@ 200mm max. centres
Form plasterboard dryback-block behind allend joints not formedon framed members
Where illustrations throughout this manual show a Suspended Ceiling System, a Direct Fixed or Furred System may also be used.
Note:
Single LayerWhere system comprises only one layer,back-blocks must be additionally fixed with cornice adhesive as follows:
• Cut back-blocking pieces from Boral Plasterboard sheet to sizes no less than 200mm wide and in lengths that will fit loosely between the framing members.
• Prepare Boral Plasterboard Cornice Adhesive in a clean container with sufficient water to make a stiff paste of smooth consistency.
• Apply adhesive over the full face of the back-blocking pieces using a notched spreader to form beads of 6mm x 6mm at approximately 20mm centres and at right angles to the joint.
• Fix Boral Plasterboard ceiling sheet transverse to framing members, placing the back-blocks centrally along the full length of the sheet's edge.
• Fix ceiling sheets to back-blocks with10 x 38mm Type L screws at 200mm max. centres.
• Immediately fix the next ceiling sheet and screw laminate to back blocks as previously.
8
Fire-rated Ceiling Systems
9
Fire-rated Ceiling Systems
Ceiling Variations using 1, 2 or 3 Layers of Plasterboard.Fire ratings of FRL 30/30/30, FRL 60/60/60, FRL 90/90/90 and FRL 120/120/120 may be achieved with various combinations of 1, 2 and 3 layers of Boral Firestop Plasterboard. Where illustrations throughout this manual give the option of using either 1, 2 or 3 layers of plasterboard, refer to the table below to select the system giving the fire and acoustic ratings required.
System Selector Table
Ceiling Variations using 4 Layers of Plasterboard.A fire rating of FRL 120/120/120 with a 120min. resistance to incipient spread of fire is achieved using four layers of 16mm Boral Firestop Plasterboard - 2 bottom layers and 2 top layers separated by a secondary furring channel framing (System CS6). For details, refer to Boral Plasterboard TecASSIST or TecSYS - a comprehensive technical catalogue on CD-ROM (see back cover).
CautionBoral Plasterboard ceiling systems are not designed
to support the weight of construction or maintenance personnel, additional plant or storage of goods.
System Selector Table
Fire Rating(FRL)
Resistance toIncipient Spread
of Fire #
Acoustic Rating(Rw)* Plasterboard
LayersSystem
FRL 30/30/30
FRL 60/60/60
FRL 90/90/90
FRL 120/120/120
30mins.
60mins.
60mins.
60mins.
30mins.
90mins.
52dB
55dB
56dB
57dB
55dB
59dB
1 layer of 16mm BoralFirestop Plasterboard
1 layer of 13mm and1 layer of 16mm BoralFirestop Plasterboard
2 layers of 16mm BoralFirestop Plasterboard
3 layers of 13mm BoralFirestop Plasterboard
2 layers of 13mm BoralFirestop Plasterboard
3 layers of 16mm BoralFirestop Plasterboard
CS17
CS15
CS15
CS21
CS20
CS22
37dB
39dB
39dB
40dB
39dB
42dB
52dB
55dB
56dB
57dB
55dB
59dB
DFS FS SS
DFS = Direct Fixed System with nominal cavity depth of 190mm between ceiling and floor.FS = Furred System with nominal cavity depth of 220mm between ceiling and floor and
Rondo P.N. 226 Direct Fixing Clip fixed to side of joist with furring channel fixed to clip.SS = Suspended System with nominal cavity depth of 350mm between ceiling and floor.PO = Plasterboard Only. The Rw rating is for the number of plasterboard layers specified.
* Acoustic ratings are based on ceiling insulation of minimum 100mm thick polyester or glass wool @ 14kg/m3.
# Also protection to loaded steel or timber beams above ceiling.
60mins. 56dB2 layers of 16mm BoralFirestop Plasterboard
CS1539dB 56dB
90mins. 59dB3 layers of 16mm BoralFirestop Plasterboard
CS1042dB 59dB
30dB
32dB
33dB
34dB
32dB
35dB
PO
33dB
35dB
8
Fire-rated Ceiling Systems
9
Fire-rated Ceiling Systems
System Selector FRL30/30/30
(Test Ref.)
SystemNo.
Fire-RatingFRL (mins)
CS17 0.5 Hour30/30/30
30 mins resistance to incipient spread
of fire
CSIRO Opinion FCO-0568
Standard Design Roof or Floor Ceiling Systems - Suspended, Direct Fixed or Furred
Description and Physical Data
System provides a variety of application configurations using 1 layer of 16mm Boral Firestop Plasterboard fixed as a Suspended, Direct Fixed or Furred System.
1 layer of 16mm Boral Firestop Plasterboard fixed to a supporting framework of timber or steel at 600mm max. centres. - Firestop is fixed across supporting members - Longitudinal joints (along recessed edges) and Butt or End Joints not formed on framing members should be back-blocked - Back blocks to be screw laminated - Fixing to framework to be as a follows: Fixed directly to timber or steel beams or purlins at 600mm max. centres or - Fixed to furring channel system at 600mm max. centres that has been - (a) clipped or direct fixed to a steel or timber floor or ceiling frame at 1200mm max.centres or - (b) clipped to top cross rails at 1200mm max. centres supported by suspension rod system hung from a concrete soffit, steel or timber floor or ceiling frame.
Ceiling System may be fixed to a pitch in the range of 0o - 70o from the horizontal or to a min. radius of 6000mm - Brace as required. Flooring over - Concrete Slab or min. 12mm plywood, timber or particle board fixed direct to frame. Roofing over - Concrete Slab, Tile, Aluminium or Steel profiled section fixed to battens or frame.
OR OR
OR
OR
Furred Channel Systems
Direct Fixed Systems
Suspended Systems
10
Fire-rated Ceiling Systems
11
Fire-rated Ceiling Systems
CS14
60 mins resistance to incipient spread
of fire
CSIRO OpinionFCO - 0794 &FCO - 0668
Upgrade of Existing Fibrous Plaster Ceiling1 Hour60/60/60 2 layers of 16mm Boral Firestop screw attached
to Rondo steel furring channels spaced at 600mm centres. Furring Channels clipped to Rondo anchor clips fixed through existing fibrous plaster ceiling to existing framing with 50mm Type W screws for soft wood framing or 40mm Type S or Type D for steel framing. Anchor clips spaced at 1200mm max. centres staggered - joints staggered - first layer butt joints may fall on one furring channel across the full width of the ceiling - face layer butt joints located on additional short lengths of furring channel and staggered- face joints finished.
CS12
60 mins resistance to incipient spread
of fire
CSIRO OpinionFCO-0467
Acoustic Suspended Ceiling under Fire-rated Ceiling System
(Test Ref.)
SystemNo.
Fire-RatingFRL (mins)
1 Hour60/60/60
System is designed to cater for fixing a suspended acoustic ceiling from a fire-rated ceiling above. For furred system - fire-rated ceiling is fixed to purlins supporting a metal deck roof at 1200mm centres using extended Rondo clips P.N.394 fastened direct to web of purlin. For direct fixed system - fire-rated ceiling is fixed directly to purlins.
Ceiling (furred) : 2 layers of 16mm Boral Firestop Plasterboard fixed to Rondo furring channel at 600mm max. centres. - Firestop is fixed across supporting member with all end joints fixed on frame, or dry back-blocked or screw fastened to previous layer. Acoustic ceiling suspended from clips screwed to furring channel.
Refer to Boral Plasterboard TecASSIST for additional details.
Total mass of suspended acousticceiling under not to exceed 12 kg/m2 for Direct Fixed System or4.95kg/m2 for Direct Clipped (Furred) System.
Ceilings are not designed for human access or construction and maintenance loadings.
OR
System Selector FRL 60/60/60
Description and Physical Data
10
Fire-rated Ceiling Systems
11
Fire-rated Ceiling Systems
System Selector FRL 60/60/60
(Test Ref.)
SystemNo.
Fire-RatingFRL (mins)
CS20 1 Hour60/60/60
30 mins resistance to incipient spread
of fire
CSIRO Opinion FC0-1658
Standard Design Roof or Floor Ceiling Systems - Suspended, Direct Fixed or Furred
System provides a variety of application configurations using 2 layers of 13mm Boral Firestop Plasterboard fixed as a Suspended, Direct Fixed or Furred System.
2 layers of 13mm Boral Firestop Plasterboard fixed to a supporting framework of timber or steel at 600mm max. centres. - Firestop is fixed across supporting members with all end joints on frame, or dry back-blocked or screw fastened to previous layer - Stagger all joints min. 200mm. Fixing to framework to be as a follows: Fixed directly to timber or steel beams or purlins at 600mm max. centres - or - Fixed to furring channel system at 600mm max. centres that has been - (a) clipped or direct fixed to a steel or timber floor or ceiling frame at 1200mm max. centres or - (b) clipped to top cross rails at 1200mm max. centres supported by suspension rod system hung from a concrete soffit, steel or timber floor or ceiling frame.
Ceiling System may be fixed to a pitch in the range of 0o - 70o from the horizontal or to a min. radius of 6000mm - Brace as required. Flooring over - Concrete Slab or min. 12mm plywood, timber or particle board fixed direct to frame. Roofing over - Concrete Slab, Tile, Aluminium or Steel profiled section fixed to battens or frame. Refer to Boral Plasterboard TecASSIST for additional details.
System provides 30 mins. protection to loaded steel or timber beams above ceiling.
Description and Physical Data
OR OR
OR
OR
Furred Channel Systems
Direct Fixed Systems
Suspended Systems
12
Fire-rated Ceiling Systems
13
Fire-rated Ceiling Systems
System Selector FRL 60/60/60
(Test Ref.)
SystemNo.
Fire-RatingFRL (mins)
CS21 1 Hour60/60/60
60 mins resistance to incipient spread
of fire
CSIRO Opinion FC0-1658
Standard Design Roof or Floor Ceiling Systems - Suspended, Direct Fixed or Furred
System provides a variety of application configurations using 1 layer of 13mm and 1 layer of 16mm Boral Firestop Plasterboard fixed as a Suspended, Direct Fixed or Furred System.
First layer of 13mm and second layer of 16mm Boral Firestop Plasterboard fixed to a supporting framework of timber or steel at 600mm max. centres. - Firestop is fixed across supporting members with all end joints on frame, or dry back-blocked or screw fastened to previous layer - Stagger all joints min. 200mm. Fixing to framework to be as a follows: Fixed directly to timber or steel beams or purlins at 600mm max. centres - or - Fixed to furring channel system at 600mm max. centres that has been - (a) clipped or direct fixed to a steel or timber floor or ceiling frame at 1200mm max. centres or - (b) clipped to top cross rails at 1200mm max. centres supported by suspension rod system hung from a concrete soffit, steel or timber floor or ceiling frame.
Ceiling System may be fixed to a pitch in the range of 0o - 70o from the horizontal or to a min. radius of 6000mm - Brace as required. Flooring over - Concrete Slab or min. 12mm plywood, timber or particle board fixed direct to frame. Roofing over - Concrete Slab, Tile, Aluminium or Steel profiled section fixed to battens or frame. Refer to Boral Plasterboard TecASSIST for additional details.
System provides 60 mins. protection to loaded steel or timber beams above ceiling.
Description and Physical Data
OR OR
OR
OR
Furred Channel Systems
Direct Fixed Systems
Suspended Systems
12
Fire-rated Ceiling Systems
13
Fire-rated Ceiling Systems
(Test Ref.)
SystemNo.
Fire-RatingFRL (mins)
CS15 11⁄2 Hour90/90/90
60 mins resistance to incipient spread
of fire
CSIRO Opinion FC0-0675
Standard Design Roof or Floor Ceiling Systems - Suspended, Direct Fixed or Furred
System provides a variety of application configurations using 2 layers of 16mm or 3 layers of 13mm Boral Firestop Plasterboard fixed as a Suspended, Direct Fixed or Furred System.
2 layers of 16mm or 3 layers of 13mm Boral Firestop Plasterboard fixed to a supporting framework of timber or steel at 600mm max. centres. - Firestop is fixed across supporting members with all end joints on frame, or dry back-blocked or screw fastened to previous layer - Stagger all joints min. 200mm. Fixing to framework to be as a follows: Fixed directly to timber or steel beams or purlins at 600mm max. centres - or - Fixed to furring channel system at 600mm max. centres that has been - (a) clipped or direct fixed to a steel or timber floor or ceiling frame at 1200mm max. centres or - (b) clipped to top cross rails at 1200mm max. centres supported by suspension rod system hung from a concrete soffit, steel or timber floor or ceiling frame.
Ceiling System may be fixed to a pitch in the range of 0o - 70o from the horizontal or to a min. radius of 6000mm - Brace as required. Flooring over - Concrete Slab or min. 12mm plywood, timber or particle board fixed direct to frame. Roofing over - Concrete Slab, Tile, Aluminium or Steel profiled section fixed to battens or frame. Refer to Boral Plasterboard TecASSIST for additional details.
OR OR
OR
OR
System Selector FRL 90/90/90
Description and Physical Data
Furred Channel Systems
Direct Fixed Systems
Suspended Systems
14
Fire-rated Ceiling Systems
15
Fire-rated Ceiling Systems
System Selector FRL 90/90/90
(Test Ref.)
SystemNo.
Fire-RatingFRL (mins) Description and Physical Data
CS10 1.5 Hour90/90/90
90 mins resistance to incipient spread
of fire
Standard Design Roof or Floor Ceiling Systems - Suspended, Direct Fixed or Furred
System provides a variety of application configurations using 3 layers of 16mm Boral Firestop Plasterboard fixed as a Suspended, Direct Fixed or Furred System.
3 layers of 16mm Boral Firestop Plasterboard fixed to a supporting framework of timber or steel at 600mm max. centres. Firestop is across supporting members with all end joints on frame, or dry back-blocked or screw fastened to previous layer. Stagger all joints min. 200mm. Fixing to framework to be as a follows: Fixed directly to timber or steel beams or purlins at 600mm max. centres - or - Fixed at 600mm max. centres to furring channel system that has been; (a) clipped or direct fixed to a steel or timber floor or ceiling frame at 1200mm max. centres - or; (b) clipped to top cross rails at 1200mm max. centres supported by suspension rod system hung from a concrete soffit, steel or timber floor or ceiling frame.
Ceiling System may be fixed to a pitch in the range of 0o - 70o from the horizontal or to a min. radius of 6000mm - brace as required. Flooring over; Concrete Slab or min. 12mm plywood, timber or particle board fixed direct to frame. Roofing over; Concrete Slab, Tile, Aluminium or Steel profiled section fixed to battens or frame. Refer to Boral Plasterboard TecASSIST for additional details.
System provides 90 mins. protection to loaded steel or timber beams above ceiling.
OR OR
OR
CSIRO Opinion FC0-0703
OR
Furred Channel Systems
Direct Fixed Systems
Suspended Systems
14
Fire-rated Ceiling Systems
15
Fire-rated Ceiling Systems
System Selector FRL 90/90/90
Description and Physical Data(Test Ref.)
SystemNo.
Fire-RatingFRL (mins)
CS8
CSIRO OpinionFCO-0605
Acoustic Suspended Ceiling under Fire-rated Ceiling System
System is designed for fixing a suspended acoustic ceiling from a fire-rated ceiling above. Fire-rated ceiling is a direct fix ceiling system to timber or steel beams or purlins using 3 layers of 16mm Boral Firestop Plasterboard - 1 bottom layer and 2 top layers for furred system or 3 layers for direct fixed system.
Primary System (furred): Top 2 layers of 16mm Boral Firestop Plasterboard fixed to a supporting framework of timber or steel at 600mm maximum centres. Firestop is fixed across supporting members with all end joints on frame, or dry back-blocked or screw fastened to previous layer. Stagger all joints min. 200mm.
Secondary System (furred): Bottom layer of 16mm Boral Firestop Plasterboard fixed to Rondo furring channel at 600mm maximum centres. Firestop is fixed across supporting member with all end joints fixed on frame or dry back-blocked.
Ceiling System may be fixed to a pitch in the range of 0o - 70o from the horizontal or to a minimum radius of 6000mm - brace as required. Flooring over; Concrete Slab or minimum 12mm plywood, timber or particle board fixed direct to frame. Roofing over; Concrete Slab, Tile, Aluminium or Steel profiled section fixed to battens or frame. Acoustic ceiling suspended from clips screwed to furring channel.
Refer to Boral Plasterboard Sales Offices for additional details.
1.5 Hour90/90/90
90 mins resistance to incipient spread
of fire
OR
Total mass of suspended acousticceiling under not to exceed12 kg/m2 for direct fixed system or 4.95kg/m2 for furred system.
Ceilings are not designed for human access or for construction and/or maintenance loadings.
System provides 90 mins. protection to loaded steel or timber beams above ceiling.
16
Fire-rated Ceiling Systems
17
Fire-rated Ceiling Systems
(Test Ref.)
SystemNo.
Fire-RatingFRL (mins)
CS6 2 Hour120/120/120
120 mins resistance to incipient spread
of fire
CSIRO Opinion FC0-0730
Standard Design Roof or Floor Ceiling Systems - Suspended, Direct Fixed or Furred
System provides a variety of application configurations using 4 layers (2 bottom & 2 top) of 16mm Boral Firestop Plasterboard fixed as a Suspended, Direct Fixed or Furred System.
Primary System: Top 2 layers of 16mm Boral Firestop Plasterboard fixed to a supporting framework of timber or steel at 600mm max. centres. Firestop is fixed across supporting members with all end joints on frame, or dry back-blocked or screw fastened to previous layer. Stagger all joints min. 200mm. Fixing to framework to be as a follows: Fixed directly to timber or steel beams or purlins at 600mm max.centres - or - Fixed at 600mm max. centres to furring channel system that has been; (a) clipped or direct fixed to a steel or timber floor or ceiling frame at 1200mm max. centres - or; (b) clipped to top cross rails at 1200mm max. centres supported by suspension rod system hung from a concrete soffit, steel or timber floor or ceiling frame.
Secondary System: Bottom 2 layers of 16mm Boral Firestop Plasterboard fixed to Rondo furring channel or resilient channel at 600mm max. centres. Firestop is fixed across supporting member with all end joints fixed on frame dry back-blocked or screw laminated to previous layer. Stagger all joints min. 200mm.
Ceiling System may be fixed to a pitch in the range of 0o - 70o from the horizontal or to a min. radius of 6000mm - brace as required. Flooring over; Concrete Slab or min. 12mm plywood, timber or particle board fixed direct to frame. Roofing over; Concrete Slab, Tile, Aluminium or Steel profiled section fixed to battens or frame.
System provides 120 mins. protection to loaded steel or timber beams above ceiling.
Refer to Boral Plasterboard TecASSIST for further details.
Furred Channel Systems
Direct Fixed Systems
Suspended Systems
OR OR
OR
OR
System Selector FRL 120/120/120
Description and Physical Data
16
Fire-rated Ceiling Systems
17
Fire-rated Ceiling Systems
System Selector FRL 120/120/120
(Test Ref.)
SystemNo.
Fire-RatingFRL (mins) Description and Physical Data
CS22 2 Hour120/120/120
90 mins resistance to incipient spread
of fire
Standard Design Roof or Floor Ceiling Systems - Suspended, Direct Fixed or Furred
System provides a variety of application configurations using 3 layers of 16mm Boral Firestop Plasterboard fixed as a Suspended, Direct Fixed or Furred System.
3 layers of 16mm Boral Firestop Plasterboard fixed to a supporting framework of timber or steel at 600mm max. centres. Firestop is across supporting members with all end joints on frame, or dry back-blocked or screw fastened to previous layer. Stagger all joints min. 200mm. Fixing to framework to be as a follows: Fixed directly to timber or steel beams or purlins at 600mm max. centres - or - Fixed at 600mm max. centres to furring channel system that has been; (a) clipped or direct fixed to a steel or timber floor or ceiling frame at 1200mm max. centres - or; (b) clipped to top cross rails at 1200mm max. centres supported by suspension rod system hung from a concrete soffit, steel or timber floor or ceiling frame.
Ceiling System may be fixed to a pitch in the range of 0o - 70o from the horizontal or to a min. radius of 6000mm - brace as required. Flooring over; Concrete Slab or min. 12mm plywood, timber or particle board fixed direct to frame. Roofing over; Concrete Slab, Tile, Aluminium or Steel profiled section fixed to battens or frame. Refer to Boral Plasterboard TecASSIST for additional details.
System provides 90 mins. protection to loaded steel or timber beams above ceiling.
OR OR
OR
CSIRO Opinion FC0-1658
OR
Furred Channel Systems
Direct Fixed Systems
Suspended Systems
18
Fire-rated Ceiling Systems
19
Fire-rated Ceiling Systems
CS7
120 mins resistance to incipient spread
of fire
CSIRO OpinionFCO-0605
Acoustic Suspended Ceiling under Fire-rated Ceiling System
(Test Ref.)
SystemNo.
Fire-RatingFRL (mins)
2 Hour120/120/120
Total mass of suspended acousticceiling under not to exceed 4.95kg/m2
Ceilings are not designed for human access or for construction and/or maintenance loadings.
System is designed for fixing a suspended acoustic ceiling from a fire-rated ceiling above. Fire-rated ceiling is a direct fix ceiling system to timber or steel beams or purlins using 4 layers (2 bottom & 2 Top) of 16mm Boral Firestop Plasterboard.
Primary System: Top 2 layers of 16mm Boral Firestop Plasterboard fixed to a supporting framework of timber or steel at 600mm max. centres. Firestop is fixed across supporting members with all end joints on frame, or dry back-blocked or screw fastened to previous layer. Stagger all joints min. 200mm.
Secondary System: Bottom 2 layers of 16mm Boral Firestop Plasterboard fixed to Rondo furring channel at 600mm max. centres. Firestop is fixed across supporting member with all end joints fixed on frame, or dry back-blocked or screw laminated to previous layer. Stagger all joints min. 200mm.
Ceiling System may be fixed to a pitch in the range of 0o - 70o from the horizontal or to a min. radius of 6000mm - brace as required. Flooring over; Concrete Slab or min. 12mm plywood, timber or particle board fixed direct to frame. Roofing over; Concrete Slab, Tile, Aluminium or Steel profiled section fixed to battens or frame. Acoustic ceiling suspended from clips screwed to furring channel.
System provides 120 mins. protection to loaded steel or timber beams above fire-rated ceiling.
Refer to Boral Plasterboard TecASSIST for additional details.
System Selector FRL 120/120/120
Description and Physical Data
18
Fire-rated Ceiling Systems
19
Fire-rated Ceiling Systems
Standard Construction
Direct Fixed Systems
OR
Roofing or floor
35mm min.
Steel or timber flooror ceiling framingmember with orwithout steel battens@ 600mm max.centres
1, 2 or 3 Layers of BoralFirestop Plasterboardas required
Note: Systems using 1, 2 or 3 layers of Boral Firestop Plasterboard provide varying FRL and Acoustic ratings. Refer to the "System Selector Table" on Page 8 for selection of the required system.
Tape and finish face layeronly - with selected BoralPlasterboard system
1, 2 or 3 layers of Boral FirestopPlasterboard fixed transverse toframing @ 600mm max.centres.All joints staggered min. 200mm.
Screws 10mm to16mm from edges
Timber or steel roof or floorframing @ 600mm max. centres
End joints formed on framing membersand staggered, otherwise end joints onfirst layer must be back blocked. Whereapplicable, second and third layersshould be screw laminated to previouslayer @ 200mm max. centres.
200mm
150mm
Plasterboard fasteners to be 200mm centres in fieldand 150mm max. centres on end joints - staggered.Refer to Page 4 for fastener details.
max.
20
Fire-rated Ceiling Systems
21
Fire-rated Ceiling Systems
Standard Construction
Direct Clipped (Furred) Systems
OR
Roofing or floor35mm min.
Steel or timber flooror ceiling frame
Rondo P.N. 129 FurringChannel @ 600mmmax. centres
Rondo P.N. 226 or 394 Clip @600mm max. centres fastenedto timber framing member withmin. two 2.8 x 30 plasterboardnails or equivalent
Rondo P.N. 226 Clip @600mm max. centres fastenedto steel framing member withmin. two 10 x 16 Type Dscrews or equivalent
1, 2 or 3 Layers of BoralFirestop Plasterboardas required
Note: Systems using 1, 2 or 3 layers of Boral Firestop Plasterboard provide varying FRL and Acoustic ratings. Refer to the "System Selector Table" on Page 8 for selection of the required system.
Rondo P.N. 237, 226 or 394Clip @ 1200mm max. centres
Tape and finish face layeronly - with selected BoralPlasterboard system
Screws 10mm to16mm from edges
200mm
150mm
Timber or steel roof or floorframing @ 1200mm max. centres
Rondo P.N. 129Furring Channel@ 600mm max.centres
1, 2 or 3 layers of Boral FirestopPlasterboard fixed transverse toFurring Channels @ 600mm max.centres.All joints staggered min. 200mm.
End joints formed on Furring Channelsand staggered, otherwise end joints onfirst layer must be back blocked. Whereapplicable, second and third layersshould be screw laminated to previouslayer @ 200mm max. centres.
Plasterboard fasteners to be 200mm centres in fieldand 150mm max. centres on end joints - staggered.Refer to Page 4 for fastener details.
max.
20
Fire-rated Ceiling Systems
21
Fire-rated Ceiling Systems
Standard Construction
Suspended Systems
Roofing or floor35mm min.
Rondo P.N. 139 Joiner
Rondo P.N. 2534 Clip
Rondo P.N. 128 TopCross Rail @ 1200mmmax. centres
Rondo P.N. 129 FurringChannel @ 600mmmax. centres
1, 2 or 3 layers of BoralFirestop Plasterboardas required
Rondo P.N. 274 Suspension Bracket fastenedto steel member with min. two 10 x 16 Type Dscrews or equivalent
Rondo P.N. 121Suspension Rods @1200mm max. centres OR OR
Steel or timber flooror ceiling frame
Rondo P.N. 274 SuspensionBracket fastened to timberframing with min. two2.8 x 30 plasterboard nailsor equivalent
Rondo P.N. 247Suspension Bracketanchored to concretesoffit to engineer’s detail
Tape and finish face layeronly - with selected BoralPlasterboard system
1, 2 or 3 layers of Boral FirestopPlasterboard fixed transverse to FurringChannels @ 600mm max.centres. Alljoints staggered min. 200mm.
Rondo P.N. 129 FurringChannel @ 600mm max.centres
Rondo P.N. 128 TopCross Rail @ 1200mmmax. centres
End joints formed on Furring Channels andstaggered, otherwise end joints on first layermust be back blocked. Where applicable,second and third layers should be screwlaminated to previous layer @ 200mmmax. centres.
Screws 10mm to16mm from edges
Rondo P.N. 139Joiner Clip
Rondo P.N. 2534Suspension Clip
1200mm max.
1200mm max.
Rondo P.N. 121Suspension Rods@ 1200 mm max.centres
200mm
150mm
Plasterboard fasteners to be 200mm centres in fieldand 150mm max. centres on end joints - staggered.Refer to Page 4 for fastener details.
max.
Note: Systems using 1, 2 or 3 layers of Boral Firestop Plasterboard provide varying FRL and Acoustic ratings. Refer to the "System Selector Table" on Page 8 for selection of the required system. Refer to Rondo catalogue - "Suspended Grid Design".
22
Fire-rated Ceiling Systems
23
Fire-rated Ceiling Systems
Standard Construction
Acoustic Suspended CeilingsNote: In each of the following acoustic suspended systems, suspension rod bracket fastening must be capable of supporting a weight of 143kg plus the self load of the system and pressure loads.
FurredDirectFastened
2 x 16mm or 3 x 13mm BoralFirestop Plasterboard
Rondo P.N. 247 Suspension Bracketscrew fixed to framing with 12 x 75type 17 roofing screw
0 to 70o o Roofing or floor35mm min.
Rondo P.N. 129 Furring Channel@ 600mm max. centres
2 x 16mm or 3 x 13mm BoralFirestop Plasterboard
Suspension Rods @ 1200mmmax.centres
Acoustic ceiling total mass not toexceed 12Kg/m for direct fastenedsystem
2Acoustic ceiling total massnot to exceed 4.95Kg/m forfurred system
2
Timber or steel framing member
Rondo P.N. 247 Suspension Bracketscrew fixed to Furring Channel with12 x 50 type 17 roofing screw
Rondo P.N. 394 Clip @ 1200mmmax. centres fastened to steelframing member
FRL 60/60/60 - System CS12
FurredDirectFastened
3 x 16mm Boral FirestopPlasterboard
0 to 70o oRondo P.N. 237 Clips @1200mmmax. centres fixed to joist or purlinwith 12 x 60 type 17 roofing screw
Roofing or floor35mm min.
Rondo P.N. 129 Furring Channel@ 600mm max. centres
2 x 16mm Boral Firestop Plasterboard
1 x 16mm Boral Firestop Plasterboard
Rondo P.N. 247 Suspension Bracketscrew fixed to furring channel with12 x 40 type 17 roofing screw
Acoustic ceiling total mass not toexceed 4.95Kg/m for furred system2
FRL 90/90/90 - System CS8
Timber or steel framing member
Rondo P.N. 247 Suspension Bracketscrew fixed to framing with 12 x 75type 17 roofing screw
Suspension Rods @ 1200mmmax.centres
Acoustic ceiling total mass not toexceed 12Kg/m for direct fastenedsystem
2
22
Fire-rated Ceiling Systems
23
Fire-rated Ceiling Systems
Cable and Loaded Penetrations
Roofing or floorBatten as required
Framing Member
Rondo P.N. 274 Suspension Bracket
Rondo P.N. 121 Suspension Rod
Rondo P.N. 2534 Suspension Clip
Cable
1, 2 or 3 layers of Boral FirestopPlasterboard as required
Rondo P.N. 129 Furring Channel
Rondo P.N. 128 Top Cross Rail
Rondo P.N. 139 Joiner
Cable Penetration Detail
Fyre Spring by PromatFyreguard. Refer to PromatFyreguard Pty Ltd. for details.
Promaseal Fire Mastic byPromat Fyreguard
Roofing or floorBatten as required
Framing Member
Rondo P.N. 274 Suspension Bracket
Rondo P.N. 121 Suspension Rod
Rondo P.N. 2534 Suspension Clip
Two 100 x 100mm pieces of16mm Boral Firestop withlower piece slotted for cable
Cable set in Boral CorniceAdhesive or approvedfire-rated sealant
Cable
Rondo P.N. 129 Furring Channel
Rondo P.N. 128 Top Cross RailRondo P.N. 139 Joiner
1, 2 or 3 layers of Boral FirestopPlasterboard as required
Alternative Cable Penetration Detail
Roofing or flooringBatten
Framing member
Rondo P.N. 274 Suspension BracketSteel Suspension Rod and Bracketto engineer’s detailsRondo P.N. 121 Suspension Rod
Rondo P.N. 2534 Suspension Clip
Rondo P.N. 128 Top Cross Rail
Rondo P.N. 139 Joiner
Rondo P.N. 129 Furring Channel
1, 2 or 3 Layers of Boral FirestopPlasterboard as required
6-10mm gap
Typical Loaded Penetration Details
Rod set in Boral Cornice Adhesiveor approved fire-rated sealant
24
Fire-rated Ceiling Systems
25
Fire-rated Ceiling Systems
Pipe Penetrations
A A
13mm max.
520mm
Roofing or flooringBatten
Framing member
Rondo P.N. 274 Suspension Bracket
100mm max. diam. Copper Pipe
Rondo P.N. 121 Suspension Rod
Rondo P.N. 2534 Suspension Clip
Rondo P.N. 128 Top Cross Rail
Rondo P.N. 139 Joiner
Rondo P.N. 129 Furring Channel
1 or 2 layers of Boral FirestopPlasterboard as required
View AA
15mm min.
Typical Copper Pipe Penetration Detail - FRL 30/30/30 and FRL 60/60/60
Cage by Promat Fyreguard(refer to Promat Fyreguard tests)50 x 20mm Promaseal IBSby Promat Fyreguard
Promaseal Fire Masticby Promat Fyreguard
Roofing or flooringBatten
Framing memberRondo P.N. 274 Suspension Bracket
uPVC Pipe independently supportedabove ceilingRondo P.N. 121 Suspension Rod
Rondo P.N. 2534 Suspension Clip
Rondo P.N. 128 Top Cross Rail
Rondo P.N. 139 Joiner
Rondo P.N. 129 Furring Channel
Steel Toggle Bolt
1, 2 or 3 layers of Boral FirestopPlasterboard as required
Typical PVC Pipe Penetration Detail
Retrofit Fyre Collar by Promat Fyreguard.Refer to Fyreguard Pty Ltd.for details.
Promat
Roofing or flooringBatten
Framing memberRondo P.N. 274 Suspension Bracket
Water pipe independently supportedabove ceiling
Rondo P.N. 121 Suspension Rod
Rondo P.N. 2534 Suspension Clip
Rondo P.N. 128 Top Cross Rail
Rondo P.N. 139 JoinerRondo P.N. 129 Furring Channel
Approved fire grade sealant
Sprinkler head
1, 2 or 3 layers of Boral FirestopPlasterboard as required
Typical Sprinkler Pipe Penetration Detail
24
Fire-rated Ceiling Systems
25
Fire-rated Ceiling Systems
Ceilings to a Radius
Roofing or flooring
Batten as required
Framing member
Rondo P.N. 128 TopCross Rail or steelangle by others rolledto required radius
Rondo P.N. 139Joiner riveted toTop Cross Rail
Rondo P.N. 129Furring Channel
1, 2 or 3 layers of BoralFirestop Plasterboardas required
Rondo P.N. 274Suspension Bracket
Rondo P.N. 121Suspension Rod
Rondo P.N. 2534Suspension Clip
Caulk all perimeter junctionswith Boral Cornice Adhesive
Taped Joint
6-10mm
Suitable screw to preventsuspension clip sliding upTop Cross Rail
6000mm
min. radius
to face of plasterboard
26
Fire-rated Ceiling Systems
27
Fire-rated Ceiling Systems
Change of Pitch
Angle Cleat
Roofing or flooringBatten as required
Framing member
Rondo P.N. 274Suspension Bracket
Rondo P.N. 121Suspension Rod @1200mm centres max.
Rondo P.N. 2534Suspension Clip
Rondo P.N. 139 Joiner
Rondo P.N. 139 Joinerpop riveted to TopCross Rail
Rondo P.N. 129 FurringChannel
1, 2 or 3 layers of BoralFirestop Plasterboardas required
Cornice Adhesive
Tape and set joint
Rondo P.N. 128 TopCross Rail
Continuous Angle 0.75B.M.T. Galv. M.S. 50mmmin. leg length
0-900
20mm max.
600mmmax.
Detail A
Angle Cleat
Roofing or flooringBatten as required
Framing memberRondo P.N. 274Suspension Bracket
Rondo P.N. 121Suspension Rod @1200mm centres max.
Rondo P.N. 2534Suspension Clip
Rondo P.N. 139 Joinerpop riveted to TopCross Rail
Rondo P.N. 129 FurringChannel
Cornice Adhesive Tape and set joint
Rondo P.N. 128 TopCross Rail
Continuous Angle 0.75B.M.T. Galv. M.S. 50mmmin. leg length
0-900
20mm max.
600mmmax.
Detail B
1, 2 or 3 layers of BoralFirestop Plasterboardas required
Angle Cleat
Roofing or flooringBatten as required
Framing member
Rondo P.N. 274Suspension Bracket
Rondo P.N. 121Suspension Rod @1200mm centres max.
Rondo P.N. 2534Suspension Clip
Rondo P.N. 139 Joinerriveted to Top Cross Rail
Rondo P.N. 129 FurringChannel
Cornice AdhesiveTape and set joint
Rondo P.N. 128 TopCross Rail
Continuous Angle 0.75B.M.T. Galv. M.S. 50mmmin. leg length
20mmmax.
20mmmax.
0-1800
Suitable screw on highside of each clip toprevent suspension clipsliding up Top Cross Rail
Detail C
1, 2 or 3 layers of BoralFirestop Plasterboardas required
26
Fire-rated Ceiling Systems
27
Fire-rated Ceiling Systems
Bulkheads
Typical Bulkhead - Detail B
600mmmax. drop
Roofing or flooring
Rondo P.N. 274 SuspensionBracket
Rondo P.N. 121Suspension Rod
Additional Rondo P.N. 121Suspension Rod
Rondo P.N. 2534 Suspension Clip
Rondo P.N. 139 Joiner
Rondo P.N. 129Furring Channel
Rondo P.N. 129 Furring Channel
Rondo P.N. 128Top Cross Rail
75 x 75 x 0.75mm BMTContinuous GalvanisedSteel Angle
Corner Bead if Required
Framing Member
1, 2 or 3 layers of BoralFirestop Plasterboardas required
Typical Bulkhead - Detail A
Roofing or flooring
Rondo P.N. 274Suspension Bracket
Rondo P.N.121Suspension Rod
Additional Rondo P.N.121Suspension Rod
Rondo P.N. 2534Suspension Clip
Rondo P.N. 2534 Suspension Clip
Rondo P.N. 139 Joiner poprivetted to Top Cross Rail
Rondo P.N. 129 Furring Channel
Rondo P.N. 129Furring Channel
1, 2 or 3 layers of BoralFirestop Plasterboardas required
Rondo P.N. 128Top Cross Rail
Rondo P.N. 128 Top Cross Rail
50mm x 50mm x 0.75mmGalvanised Steel Angle
Corner Bead if Required
Framing Member
25 x 25 x 0.75mm BMTGalvanised Angle poprivetted to Top Cross Rail
600mmmax. drop
28
Fire-rated Ceiling Systems
29
Fire-rated Ceiling Systems
Bulkheads
Skylight Dome
Skylight Framing
1, 2 or 3 layers of BoralFirestop Plasterboardas required
1, 2 or 3 layers of BoralFirestop Plasterboardas required
Framing Member
Timber or Steel StudFrame @ 600mmcentres
50 x 50 x 0.75mmcontinuous galv.Steel Angle
External Corner Beadif required600mm max. centres
Rondo P.N. 139Joiner
Rondo P.N. 129Furring Channel
Rondo P.N. 128Top Cross Rail
Rondo P.N. 2534Suspension Clip
Rondo P.N. 121Suspension Rod
Rondo P.N. 274Suspension Bracket
Roof Battens
Upstand Framing
Flashing
Roofing as required
600mmmax. drop
Typical Bulkhead/Lightwell Detail
28
Fire-rated Ceiling Systems
29
Fire-rated Ceiling Systems
Light Recess
Framing Member
Prefabricated MetalLight Stirrup
Flooring or Roof
Rondo P.N. 274Suspension BracketRondo P.N. 121
Suspension Rodspaced to supportany additional massdue to light fitting
Rondo P.N. 2534Suspension Clip
Rondo P.N. 128Top Cross Rail
1, 2 or 3 layers of BoralFirestop Plasterboardas required
Rondo P.N. 129Furring Channel
100mm
450mm
Light Fitting Box
Support Mounting
Typical Light Recess - Detail A
1, 2 or 3 layers of BoralFirestop Plasterboardas required
Typical Light Recess - Detail B
Timber Floor
TrimmerFloor Joist
Trimmer
Light Fitting
50mm x 50mm x 0.75mmGalvanised Steel Angles
Floor or CeilingStructure
Rondo P.N. 274Suspension BracketRondo P.N. 121
Suspension Rodspaced to supportany additional massdue to light fitting
64CS Stud Frame@ 600mm centres
Rondo P.N. 2534Suspension Clip
50 x 50 x 0.75mmAngle fixed to Studand Top Cross Rail
50 x 50 x 0.75mmGalv. Steel Angle
75 x75 x 0.75mmGalv. Steel Angle
Rondo P.N. 128Top Cross Rail
Rondo P.N. 139Joiner
1, 2 or 3 layers of BoralFirestop Plasterboardas required
Rondo P.N. 129Furring Channel
100mm
Light Fitting Box
Support Mounting
Additional RondoP.N. 121 SuspensionRod
Typical Light Recess - Detail C
30
Fire-rated Ceiling Systems
31
Fire-rated Ceiling Systems
Access Hatch
600mm
670mm
B B
A
A
Section B-B
Additional TopCross Rail
Rondo P.N. 129Furring Channel
Ceiling FurringChannel
2 x 13mm BoralFirestop Plasterboard
1, 2 or 3 layers of Boral FirestopPlasterboard as required
750mm
540mm400mm
900mm
50mm
50mm
300mm
390mm
450mm
Section A-A
50mm
50mm
Typical Access Hatch - Detail A
670mm lengths ofTop Cross Rail
30
Fire-rated Ceiling Systems
31
Fire-rated Ceiling Systems
Access Hatch
Frame around openingwith 25mm x 25mm x 0.75Galvanised Steel Angle
1, 2 or 3 layers of BoralFirestop Plasterboardas required
1, 2 or 3 layers of BoralFirestop Plasterboardas required
FRL 30/30/30 and FRL 60/60/60:1 layer 16mm Boral Firestop PlasterboardFRL 90/90/90 and FRL 120/120/120:2 layers 16mm Boral Firestop Plasterboard
Roofing or flooring
Roofing or flooring
Batten as required
Framing member
Framing member
Rondo P.N. 274Suspension Bracket
Rondo P.N. 121Suspension Rod @1200mm centres max.
Rondo P.N. 2534Suspension Clip
Rondo P.N. 139 Joiner
Rondo P.N. 129Furring Channel
Rondo P.N. 128 TopCross Rail
10 x 38 Type L screws@ 200mm max. centres
External CornerBeads if required
Max. 500 x 500Panel
3mm gap
Typical Access Hatch - Detail B
Corner bead
64mm Track Sectionframing opening fixed toFurring Channel with25@ 200mm centres
mm Type S screws
75mm x 1mm thick SteelSection spot welded toAngles @ 200mm max.centres
Access Hatch framedwith Rondo 64CT Trackor Timber Section min.100mm x 50mm fixedto ceiling /roof framing
Promat Fyreguard AccessHatch max. 500 x 700mm
Roofing or flooring
Framing member
Rondo P.N. 274Suspension Bracket
Rondo P.N. 121Suspension Rod @1200mm centres max.
Rondo P.N. 2534Suspension Clip
Rondo P.N. 139Joiner Rondo P.N. 129
Furring Channel
FRL 30/30/30:1 x 16mm BoralFirestop PlasterboardFRL 60/60/60:2 x 16mm BoralFirestop Plasterboard
Rondo P.N. 128Top Cross Rail
Type S screws @ 200mmcentres securing Access HatchAssembly to 64mm Track Section
Type S screws @ 200mmcentres securingPlasterboard to 64mmTrack Section
Typical Access Hatch - Detail C (for up to FRL 60/60/60)
Refer to Promat Fyreguard Pty. Ltd. for installation details.
Promat Fyreguard AccessHatch max. 500 x 700mm
32
Fire-rated Ceiling Systems
33
Fire-rated Ceiling Systems
Beam Protection
Steel Beam
Roofing or Flooring
Rondo P.N. 226or 394 Direct FixingClip
Rondo P.N. 129Furring Channel
50 x 50 x 0.75mm or75 x 75 x 0.75mmcontinuous Galv.Steel Angles asrequired
50 x 50 x 0.75mmcontinuous Galv.Steel Angles
1, 2 or 3 layers ofBoral FirestopPlasterboard asrequired
1, 2 or 3 layers ofBoral FirestopPlasterboard asrequired
Furring ChannelStirrups @ 600mmcentres
Corner Beadif required
Framing member
Note: Vertical plasterboard fixed as per ceiling
Typical Steel Beam Protection Detail
Steel Beam
Roofing or Flooring Rondo P.N. 226 or394 Direct FixingClip
Rondo P.N. 129Furring Channel
50 x 50 x 0.75mmcontinuous Galv.Steel Angles
Furring ChannelStirrups @ 600mmcentres
Corner Beadsif required
Framing members@ 600mm centres
Type S screws as required@ 200mm max. centres
Typical Steel Beam Protection Detail - Perspective View
1, 2 or 3 layers ofBoral FirestopPlasterboard asrequired
1, 2 or 3 layers ofBoral FirestopPlasterboard asrequired
50 x 50 x 0.75mm or75 x 75 x 0.75mmcontinuous Galv.Steel Angles asrequired
32
Fire-rated Ceiling Systems
33
Fire-rated Ceiling Systems
Beam Protection
50mmmin.
Plasterboard Nailsas required @200mm centres
Timber Beam
Timber Floor
Rondo P.N. 226 or394 Direct FixingClip
Rondo P.N. 129Furring Channel
Corner Beadif required
Framing member
1, 2 or 3 layers ofBoral FirestopPlasterboard asrequired
Typical Timber Beam Protection - Furred System
50 x 50 x 0.75mm or75 x 75 x 0.75mmcontinuous Galv.Steel Angles asrequired
1, 2 or 3 layers ofBoral FirestopPlasterboard asrequired - max.span of 600mm forceiling layers
Rondo P.N. 226 or394 Direct FixingClip
Rondo P.N. 129Furring Channel
Roofing or Flooring
Timber Beam
Framing members@ max. 600mmcentres
Corner Beadsif required
Type S screws as required@ 200mm max. centres
1, 2 or 3 layers ofBoral FirestopPlasterboard asrequired
1, 2 or 3 layers ofBoral FirestopPlasterboard asrequired
Typical Timber Beam Protection - Perspective View - Furred System
Plasterboard Nails as required@ 200mm centres
50 x 50 x 0.75mm or75 x 75 x 0.75mmcontinuous Galv.Steel Angles asrequired
34
Fire-rated Ceiling Systems
35
Fire-rated Ceiling Systems
Beam Protection
50mmmin.
Plasterboard Nailsas required @200mm centres
Timber Floor
Corner Beadif required
Framing member
1, 2 or 3 layers ofBoral FirestopPlasterboard asrequired
1, 2 or 3 layers ofBoral FirestopPlasterboard asrequired - max.span of 600mm forceiling layers
Typical Timber Beam Protection - Direct Fixed System
50 x 50 x 0.75mmor 75 x 75 x 0.75mmcontinuous Galv.Steel Angles asrequired
Timber Beam ofnot less than500kg/m averagedensity
3
Roofing or Flooring
Timber Beam ofnot less than500kg/m averagedensity
3
Framing members@ max. 600mmcentres
Corner Beadsif required
1, 2 or 3 layers ofBoral FirestopPlasterboard asrequired
1, 2 or 3 layers ofBoral FirestopPlasterboard asrequired
Typical Timber Beam Protection - Perspective View - Direct Fixed System
Plasterboard Nails as required@ 200mm centres
50 x 50 x 0.75mm or75 x 75 x 0.75mmcontinuous Galv.Steel Angles asrequired
34
Fire-rated Ceiling Systems
35
Fire-rated Ceiling Systems
Joints
Framing member
Rondo P.N. 274 Suspension BracketRondo P.N. 121 Suspension Rod@ 1200mm max. centres
Rondo P.N. 2534 Suspension Clip
Rondo P.N. 2534 Suspension Clip
Rondo P.N. 128 or 127 Top Cross Rail
Rondo P.N. 128 or 127 Top Cross Rail
Rondo P.N. 139 Joiner
Rondo P.N. 139 Joiner
Rondo P.N. 129 Furring Channel
Rondo P.N. 129 Furring Channel
1, 2 or 3 layers of Boral FirestopPlasterboard as required
1, 2 or 3 layers of Boral FirestopPlasterboard as required
FRL 30/30/30: 1 x 16mm BoralFirestop Plasterboard.FRL 60/60/60 and FRL 90/90/90:2 x 16mm Boral FirestopPlasterboard.
FRL 30/30/30: 1 x 16mm BoralFirestop Plasterboard.FRL 60/60/60 and FRL 90/90/90:2 x 16mm Boral FirestopPlasterboard.
120mm
120mm
100mm max. 50mm
50mm
20mm
20mm
20mm max.
20mm max.
View parallel toFurring Channel
View perpendicularto Furring Channel
Minimum 6 x 50 Type L screws toone side only @ 200mm max. centres
Rondo P.N. P35 Expansion JointBead if required
Roofing or flooring
Typical Movement Joint Detail
Typical Control Joint Detail
Note: 1. Locate joint centrally between framing members when parallel to framing.2. Minimum of one layer of Boral Firestop Plasterboard continuous over joint.3. Ensure single layer system is back blocked.
1, 2 or 3 layers of Boral FirestopPlasterboard as required
10-12mm
Type L screws @ 200mm centres
Approved fire grade sealant
Framing
36
Fire-rated Ceiling Systems
37
Fire-rated Ceiling Systems
Perimeter Details
Alternative Detail
6-10mm
6-10mm
Roofing or flooring
Framing member
Batten as required
Rondo P.N. 274 Suspension Bracket
Rondo P.N. 121 Suspension Rod@ 1200mm max. centres
Plasterboard Cornice or tapedsquare set finish
Continuous Rondo P.N. 553 Angleor Steel Stud fastened to wall@ 600mm max. centres
Rondo P.N. 2534 Suspension ClipRondo P.N. 128 Top Cross Rail
Rondo P.N. 139 Joiner
Approved Sealant
Rondo P.N. 129 Furring Channel
1 x 16mm Boral Firestop Plasterboard
1 x 16mm Boral Firestop Plasterboard
100mmmax.
100mmmax.
Boral Cornice Adhesive
Typical Perimeter Detail - FRL 30/30/30
36
Fire-rated Ceiling Systems
37
Fire-rated Ceiling Systems
Perimeter Details
6-10mm
6-10mm
6-10mm
See AlternativeDetails below
Shadowline TrimWall Trim
Roofing or flooring
Framing member
Batten as required
Rondo P.N. 274 Suspension Bracket
Rondo P.N. 121 Suspension Rod@ 1200mm max. centres
Plasterboard Cornice or tapedsquare set finish
Continuous Rondo P.N. 553 Angleor Steel Stud fastened to wall@ 600mm max. centres
Rondo P.N. 2534 Suspension ClipRondo P.N. 128 Top Cross Rail
Rondo P.N. 139 Joiner
Boral Cornice Adhesive or CeramicFibre Blanket or approved sealant
Rondo P.N. 129 Furring Channel
2 or 3 layers of BoralFirestop Plasterboardas required
2 or 3 layers of BoralFirestop Plasterboardas required
2 or 3 layers of Boral FirestopPlasterboard as required
90mm PlasterboardCornice
Cornice Adhesive
10mm Boral StandardCore Plasterboard
Rondo P.N. DU05Wall Trim
Framing Top Plate 45mm thick
Plasterboard Cornice
25 x 25mm fillet ofCornice Adhesive
25 x 25mm fillet ofCornice Adhesive
Rondo P.N. 554 Angle
Rondo P.N. P50Shadowline Trim10mm
100mmmax.
100mmmax.
3-10mm
16mm max.
5mm max.o/hang
Plasterboard CorniceDetail A
Plasterboard CorniceDetail B
Typical Perimeter Detail - FRL 60/60/60
22mm Promaseal IBSby Promat Fyreguard
38
Fire-rated Ceiling Systems
39
Non Fire-rated Ceiling Systems
Perimeter Details
Roofing or flooring
Framing member
Framing
Rondo P.N. 274 Suspension Bracket
Rondo P.N. 121 Suspension Rod@ 1200mm max. centres
Cornice Adhesive
Plasterboard Cornice ortaped square set finish
Optional Plasterboard Corniceor taped square set finish
Continuous Rondo P.N. 553 Angleor Steel Stud fastened to wall@ 600mm max. centres
Rondo P.N. 2534 Suspension Clip
Rondo P.N. 128 Top Cross Rail
Rondo P.N. 139 Joiner
Approved fire-rated sealant
Rondo P.N. 129 Furring Channel
3 x 16mm Boral Firestop Plasterboard
3 x 16mm Boral Firestop Plasterboard
Alternative Detail
600mm max.
100mm max.
6-10mm
6-10mm
Typical Perimeter Detail - FRL 90/90/90
38
Fire-rated Ceiling Systems
39
Non Fire-rated Ceiling Systems
IntroductionBoral Plasterboard Non Fire-Rated Ceiling Systems provide a variety of application configurations using 1 layer of 10mm or 13mm Boral Plasterboard Standard Core or 10mm Boral Unispan fixed as a Suspended, Direct Fixed or Furred System.Note:
• These ceiling construction details are not suitable for external ceilings.
• Thermal or acoustic insulation (max. 3kg/m2) may be placed above ceiling.
Early Fire Hazard PropertiesBoral Plasterboard Standard Core, tested for early fire hazard properties in accordance with Australian Standard 1530.3 - 1982, recorded the following results:Ignitability (0-20) -14; Smoke Developed (0-10) -2; Spread of Flame (0-10) -0; Heat Evolved (0-10) -1.
Component Mass• One layer of 10mm Boral Standard Core
Plasterboard has a mass of approximately 6.5kg/m2;
• One layer of 13mm Boral Standard Core Plasterboard has a mass of approximately 8.5kg/m2;
• One layer of 10mm Boral Unispan Plasterboard has a mass of approximately 6.7kg/m2;
• Rondo Furring Channel Part No. 129 has a mass of approximately 0.5kg/m;
• Rondo Top Cross Rail Part No. 128 has a mass of approximately 0.7kg/m.
Systems MassThe following table shows mass calculations based on the above approximations:
DecorationThe ceiling system is flush jointed to provide a smooth, continuous surface ideal for all forms of decoration. Care must be taken to apply paint or other finishes strictly in accordance with the Manufacturer’s instructions.
General Construction DetailsMovement joints should be put at building construction joint locations. Control joints should be spaced at not more than 12 metre max. centres in either direction or 15 metre centres where there is perimeter relief.
Where necessary specify a furred system to minimise the risk of ceiling damage due to frame movement caused by structural, thermal and seasoning effects.Caution:Boral Plasterboard ceiling systems are not designed to support the weight of maintenance personnel, additional plant or storage of goods.
Materials• 10mm or 13mm Boral Plasterboard Standard
Core or 10mm Boral Unispan.• Boral Plasterboard Jointing Compound
(as preferred from the Boral Plasterboard Jointing Compound range).
• Boral Plasterboard Cornice 55mm, 75mm & 90mm if required, applied using Boral Plasterboard Cornice Adhesive or Cornice Adhesive Mid Set.
• Boral Plasterboard Stud Adhesive.• Perforated paper tape.• An approved caulking compound for
caulking gaps at ceiling perimeters.• Screws and nails as specified.• Rivets (all steel).
Refer to Safety Data Sheets (available from Boral Plasterboard Sales Offices) or the container labelling, when handling relevant products.
All materials must be carefully stored and protected on the construction site. Damaged plasterboard sheets and accessory materials must not be used. Plasterboard is to be stacked flat and protected from moisture and must not be used where it will be exposed to excessive moisture.
Rondo Fixing and Suspension ComponentsManufactured by Rondo Building Services Ltd. and marketed by Boral Plasterboard:
129 - Furring Channel127 - Top Cross Rail139 - Joiner to Top Cross Rail237, 226, 394 - Direct Fixing Clips247 or 274 - Suspension Bracket121 - Suspension Rod2534 - Adjustable Suspension ClipP32 - Corner Bead553 - All Steel Angle 35x35x0.75554 - All Steel Angle 50x50x0.75P35 - Rondo Control Joint
Standard Ceilings Design
PlasterboardLayers
PlasterboardMass
SuspensionSystem Mass*
1 x 10mm1 x 13mm1 x 10mm Unispan
6.5kg/m2
8.5kg/m2
6.7kg/m2
8.5kg/m2
10.5kg/m2
8.7kg/m2
* The suspension system mass is approximate only and based on a Rondo steel suspension system with Top Cross Rails @ 1200mm centres, Furring Channels @ 600mm max. centres (450mm max. centres for 10mm Standard Core Plasterboard) and an average drop.
40
Non Fire-rated Ceiling Systems
41
Non Fire-rated Ceiling Systems
Standard Ceilings Design
InstallationFurring channel and framing supports to be taken to and provided within 50mm of ceiling perimeter - min 15mm end clearance to walls.
Suspension Systems• Attach suspension rods to suspension rod
brackets that are anchored to structural framing or concrete soffit, at typically 1200mm centres in each direction.
Note: Each suspension rod bracket fastening must be capable of supporting a weight of 143kg plus the self load of the system and pressure loads.
• Attach suspension clips to top cross rails, and fit suspension clips to rods. Adjust the rails to a true and level plane.
• Position furring channels at 600mm maximum centres (see note) and attach to top cross rails with a locking clip at each intersection.
• Join lengths of furring channel with furring channel joiners, ensuring the joins are staggered.
• Extra suspension components must be provided to support light fittings, bulkheads and other fixtures. Spans and spacings may be reduced if required.
Direct Clipped (Furred) SystemsPosition furring channels at 600mm maximum centres (see note) and attach channels to structural framing with direct fixing clips at typically 1200mm centres, or to concrete soffit with anchor clips fastened to soffit at typically 1200mm centres. Ensure that furring channels are fixed to a true and level plane. Longer spans may be used - refer to Manufacturer's details.
Direct Fixed SystemsWhere fixing direct to timber or steel framing without furring channel, framework should not exceed 600mm spacing (see note). Spans and spacings may be reduced if required.
Plasterboard Application• Plasterboard may be fixed with nails,
screws or a combination of adhesive and fasteners. A combination of adhesive and fasteners is the preferred method for general application.
• Fix Boral Plasterboard across the Furring Channel, Timber or Steel framing.
• Butt or end joints not formed on framing members should be back-blocked as described under "Back-blocking".
• Tape and finish with preferred Boral Plasterboard jointing system.
Adhesive/ Fastener Fixing• Apply Boral Plasterboard Stud Adhesive
to framing members in daubs measuring 25mm diameter by 15mm high.
• Space daubs of adhesive at 230mm maximum centres.
• Keep daubs approximately 200mm away from the edges of the sheets and the nail or screw fixing points.
• Under slow-drying conditions, keep Boral Plasterboard sheets firm against the adhesive daubs for at least 48 hours. Use temporary blocks fastened through plasterboard to framing members.
• Be sure to fix Boral Plasterboard within thirty minutes of applying adhesive. This will avoid skin forming on the adhesive.
For the number of nails or screws required, and their fixing points, refer to the following tables and illustrations.
PlasterboardWidth
900mm1200mm1350mm
FAF/FAFFAAF/FAAFFAAF/FAAF
FAFAFFAFAFAFFAFAFAF
Conventional Spacing 1/3 Spacing
F = Nail or Screw A = Adhesive F/F = 2 Nails or 1 Screw
PlasterboardWidth
SingleNails
Double Nails or Single Screws
900mm1200mm1350mm
678
456
Minimum Fixing Points per Sheet Width
All Mechanical Fixing Layout
Fasteners
Adhesive and Fastener Layout
Note: Furring channel spacing to be 450mm for 10mm Standard Core Plasterboard.
Smooth Shank Gold Passivated
Annular Ring Shank and
Uninail
Layers of Plasterboardx Thickness
1 x 10mm
1 x 13mm
40mm¹30mm²40mm¹30mm²
1 = Softwood 2 = Hardwood
30mm¹30mm²30mm¹30mm²
Galvanised 2.8mm
Diameter 40mm¹30mm²40mm¹30mm²
Nails - Timber Frame
Type W
6 - 9 x 32mm6 - 9 x 32mm
1 x 10mm1 x 13mm
Screws - Timber Frame Screws - Steel Frame
Type S or Type D
Layers of Plasterboardx Thickness
6 - 18 x 25mm*6 - 18 x 25mm*
Screw identification is given as:(min. gauge) - (threads/inch ±1) x (min. length).
* For ease of construction with framing steel gauges of less than 0.8mm BMT, use 30mm minimum length screws.
40
Non Fire-rated Ceiling Systems
41
Non Fire-rated Ceiling Systems
Standard Ceilings Design
Fixing With Nails OnlyThis method normally applies where adhesive cannot be used - e.g., over existing linings or over a water vapour barrier.
• Keep Boral Plasterboard sheets in firm contact with framing member while nails are being driven.
• Drive nail heads slightly below the surface of the sheet without puncturing the face linerboard.
• Along the perimeter of sheets, space nails at between 10mm minimum and 16mm maximum away from the edges and ends of the sheet.
• Skew-nailing is not permitted.
For single nailing, space nails at 200mm maximum centres. For double nailing, space nails at 300mm maximum centres with single nails or single screws at perimeter only.
Fixing With Screws OnlySpace screws at 300mm maximum centres in field of board and 200mm maximum centres on end joints (staggered). Space screws at 10mm - 16mm from the edges and ends.
When screw-fixing single layers of Boral Plasterboard sheets:
• Hold plasterboard sheets firmly in place against the framing members while driving in the screws.
• Adjust screw gun correctly so as to drive the screw heads below the surface of the sheet without puncturing the face linerboard.
• Press tip of screw firmly into the face linerboard before driving it home.
• Always drive screws with the shank at right angles to the face of the sheets.
• Wherever possible always start from the centre of the sheet towards the outer edges.
• Position screws on adjacent edges opposite each other.
CL
CL
CL50-75mm
4 daubs of adhesive, 25mm dia. x 15mm high,for sheets 1200mm and 1350mm wide
200mm
200mm
Daubs of adhesive 200mmfrom edge of sheets Centre line of sheet
Centre line of sheets
CL
CL
CL
Stagger butt jointsbetween framing
Double Nailing Only:50mm - 75mm apart at300mm max. centres Screws Only:
300mm max. centres
Single Nailing Only:200mm max. centres
Along perimeter of sheet, singlenails or single screws only at10mm - 16mm from edge
Adhesive Fixing
Screw or Nail Fixing
42
Non Fire-rated Ceiling Systems
43
Non Fire-rated Ceiling Systems
Back-blocking Ceilings Under Floors and Low-Pitched RoofsThis can be carried out from the floor below, one step at a time as follows (see Figure 2):
• Fix the first Boral Plasterboard sheet.• Cut the next sheet.• Apply Boral Plasterboard Cornice Adhesive
to back-blocks and place them between framing members along the full length of the sheet already fixed.
• Immediately after all blocks are in place, install the next sheet.
• Continue as above across the entire ceiling area.
• When complete, and the adhesive has thoroughly set, apply the flush-jointing.
Back-blocking Butt JointsBack-block butt joints as follows (see Figure 3):
• Fix ceiling sheets with ends butted neatly together. The butt joint should fall within 50mm of the mid-span point between framing members.
• Use battens and packers to support and deflect the sheet ends upwards about 2mm.
Figure 2.
Back-blocks in place
Boral Plasterboard ceiling
Ceiling joist or bottom chordof roof truss
Wall
Figure 1.
Back-blocking piecesof Boral Plasterboardsheet 200mm widemin. glued withCornice Adhesive
Roof truss
Boral Plasterboardceiling
Standard Ceilings Design
Back-blockingBack-blocking is a mandatory fixing requirement where specified in the Australian StandardAS/NZS 2589.1:1997.
Failure to provide back-blocking installed as per AS/NZS 2589.1:1997 may result in liability for any associated costs relating to maintenance and/or rectification caused by jointing defects.
Back-blocking substantially reduces call-backs, in particular for cracking and peaking joints.
Recessed Joints in CeilingsAny area containing three or more recessed joints must be back-blocked as follows (see Figure 1):
• Cut back-blocking pieces from Boral Plasterboard sheet to sizes no less than 200mm wide and in lengths that will fit loosely between the framing members.
• Prepare Boral Plasterboard Cornice Adhesive in a clean container with sufficient water to make a stiff paste of smooth consistency.
• Apply adhesive over the full face of the back-blocking pieces using a notched spreader to form beads of 6mm x 6mm at approximately 20mm centres and at right angles to the joint.
• Fix Boral Plasterboard ceiling sheet transverse to framing members, placing the back-blocks centrally along the full length of the sheet's edge.
• Fix the next sheets immediately after the blocks are in place.
Back-blocks in ceilings may be cemented into position from within the roof cavity using a more fluid adhesive mix and pouring it onto the top of the ceiling join before seating the back-blocks onto the adhesive.
42
Non Fire-rated Ceiling Systems
43
Non Fire-rated Ceiling Systems
Back-blocking Dos & Don'ts• Back-blocking must be installed at the fixing
stage.• Joints must not be set prior to back-blocking.• Do not use plaster in its advanced setting
state or any dry mix compound for back-blocking. Dry or partly dry compounds combined with ceiling temperatures may cause premature dry-out and reduced bond.
• Ensure back-blocking is completely dry prior to the taping process.
• Do not use stud adhesive for back-blocking.• Back-blocking strips should not be tight
between framing members.
Figure 3.
Architectural SpecificationBoral Plasterboard Ceilings shown in the relevant drawings shall consist of materials supplied by Boral Plasterboard, fixed and finished in accordance with the instructions contained in Boral Plasterboard Technical Manuals and in TecSYS - a comprehensive technical catalogue on CD-ROM (see back cover for details).
As drawings are updated from time to time, users are advised to check drawing currency before adopting the procedures and details noted thereon.
Rafter or joistBack-block
Temporary battens
PlasterboardTemporary nailing
Cornice adhesive
Packing strip
Standard Ceilings Design
44
Non Fire-rated Ceiling Systems
45
Non Fire-rated Ceiling Systems
OR OR
(Test Ref.)
SystemNo.
Fire-RatingFRL (mins)
CS18 Non FireRatedCeiling
Standard Design Roof or Floor Ceiling Systems - Suspended, Direct Fixed or Furred
Description and Physical Data
Furred Channel Systems
Direct Fixed Systems
Suspended Systems
OR
OR
System provides a variety of application configurations using 1 layer of 10mm or 13mm Boral Plasterboard Standard Core or 10mm Boral Unispan fixed as a Suspended, Direct Fixed or Furred System.
1 layer of 10mm or 13mm Boral Plasterboard Standard Core or 10mm Boral Unispan fixed to a supporting framework of timber / steel at 600mm (450mm for 10mm Boral Plasterboard Standard Core) max. centres. - Plasterboard is fixed across supporting members -Longitudinal joints (along recessed edges) and Butt or End Joints not formed on framing members should be back blocked - Back blocks to be laminated with daubs of Cornice Adhesive - Fixing to framework to be as a follows: Fixed directly to timber / steel beams or purlins at 600mm (450mm for 10mm Boral Plasterboard Standard Core) max. centres - or - Fixed to furring channel system at 600mm max. centres that has been -( a) clipped or direct fixed to a steel or timber floor / ceiling frame at 1200mm max. centres - or - (b) clipped to top cross rails at 1200mm max. centres supported by suspension rod system hung from a conc. soffit, steel or timber floor / ceiling frame.
Flooring over - Concrete Slab or min. 12mm plywood or particle board fixed direct to frame. Roofing over -Concrete Slab, Tile, Aluminium or Steel profiled section fixed to battens or frame.
System Selector
44
Non Fire-rated Ceiling Systems
45
Non Fire-rated Ceiling Systems
Tape and finish withpreferred BoralPlasterboard system
Screw fastening is illustrated using min. 6 x 32Type W screws for timber or 6 x 25 Type S orType D screws for steel. Screws to be max.300mm centres in field and 200mm max. centreson end joints (staggered). Refer to “PlasterboardApplication” on Page 40 for details of adhesiveor nail fixing.
End joints formed onframing members andstaggered
Screws 10mm to16mm from edges
300mm
200mm
Timber or steel roof orfloor framing @ 600mmmax. centres (450mm max.centres for 10mm StandardCore Plasterboard).
Note: All joints not formedon a framing member mustbe back blocked
1 layer of 10mm or 13mm Boral Standard CorePlasterboard or 10mm Boral Unispan fixedtransverse to ceiling joists.
Back blocks laminated to face sheet withcornice adhesive on all longitudinaljoints and on butt or end joints
Standard Construction
Direct Fixed Systems
OR
Roofing or floor 35mm min.
Steel or timber floor or ceilingframing member with orwithout steel battens @ 600mmmax. centres (450mm max.centres for 10mm StandardCore Plasterboard).
1 layer of 10mm or 13mm BoralStandard Core Plasterboard or10mm Boral Unispan
46
Non Fire-rated Ceiling Systems
47
Non Fire-rated Ceiling Systems
Standard Construction
Direct Clipped (Furred) Systems
OR
Roofing or floor 35mm min. Steel or timber flooror ceiling frame
Rondo P.N. 129 FurringChannel @ 600mmmax. centres (450mm max.centres for 10mm StandardCore Plasterboard).
Rondo P.N. 226 or 394 Clip @600mm max. centres fastenedto timber framing member withmin. two 2.8 x 30 plasterboardnails or equivalent
Rondo P.N. 226 Clip @600mm max. centres fastenedto steel framing member withmin. two 10 x 16 Type Dscrews or equivalent
1 layer of 10mm or 13mm BoralStandard Core Plasterboard or10mm Boral Unispan
Rondo P.N. 226 or 394Clip @ 1200mm max.centres
Tape and finish withpreferred BoralPlasterboard system
End joints formed on FurringChannels and staggered
Screws 10mm to16mm from edges
Timber or steel roofor floor framing @1200mm max. centres
Note: All joints not formedon a Furring Channel mustbe back blocked
1 layer of 10mm or 13mm Boral StandardCore Plasterboard or 10mm Boral Unispanfixed transverse to Furring Channels
Back blocks laminated to face sheet withcornice adhesive on all longitudinaljoints and on butt or end joints
Screw fastening is illustrated using min.6 x 25 Type S or Type D screws. Screws tobe max. 300mm centres in field and 200mmmax. centres on end joints (staggered).Refer to “Plasterboard Application” onPage 40 for details of adhesive or nail fixing.
300mm200mm
Rondo P.N. 129 Furring Channel@ 600mm max. centres(450mm max. centres for 10mmStandard Core Plasterboard).
46
Non Fire-rated Ceiling Systems
47
Non Fire-rated Ceiling Systems
Standard Construction
Suspended Systems
Roofing or floor35mm min.
Rondo P.N. 139 Joiner
Rondo P.N. 2534 Clip
Rondo P.N. 128 TopCross Rail @ 1200mmmax. centres
Rondo P.N. 129 FurringChannel @ 600mmmax. centres (450mm max.centres for 10mm StandardCore Plasterboard)
Rondo P.N. 274 Suspension Bracket fastenedto steel member with min. two 10 x 16 Type Dscrews or equivalent
Rondo P.N. 121Suspension Rods @1200mm max. centres OR OR
Steel or timber flooror ceiling frame
Rondo P.N. 274 SuspensionBracket fastened to timberframing with min. two2.8 x 30 plasterboard nailsor equivalent
Rondo P.N. 247Suspension Bracketanchored to concretesoffit to engineer’s detail
1 layer of 10mm or 13mm BoralStandard Core Plasterboard or10mm Boral Unispan
Tape and finish withpreferred BoralPlasterboard joiningsystem
1 layer of 10mm or 13mm BoralStandard Core Plasterboard or10mm Boral Unispan fixedtransverse to Furring Channels
Rondo P.N. 129 Furringchannel @ 600mm max.centres (450mm max.centres for 10mm StandardCore Plasterboard)
Rondo P.N. 128 TopCross Rail @ 1200mmtypical centres
Screws 10mm to16mm from edges
300mm
200mm
Rondo P.N. 139Joiner
Rondo P.N. 2534Suspension Clip
1200mm typical
1200mm typical
Rondo P.N. 121 SuspensionRods @ 1200 mm typical centresNote: All joints not formed
on a Furring Channel mustbe back blocked
Back blocks laminated to face sheet withcornice adhesive on all longitudinaljoints and on butt or end joints
Screw fastening is illustrated using min.6 x 25 Type S or Type D screws. Screws tobe max. 300mm centres in field and 200mmmax. centres on end joints (staggered).Refer to “Plasterboard Application” onPage 40 for details of adhesive or nail fixing.
48
Non Fire-rated Ceiling Systems
49
QuietZone™ Ceiling Systems
Rondo P.N. 121Suspension Rod
Rondo P.N. 2534Suspension Clip
Rondo P.N. 139Joiner
Rondo P.N. 129Furring Channel
Rondo P.N. 127Top Cross RailContinuous
GalvanisedSteel Angle
Corner Beadif required
Typical Bulkhead Details
Rondo P.N.121Suspension Rod
Rondo P.N. 2534Suspension Clip
Rondo P.N. 139Joiner poprivetted toTop Cross Rail
Rondo P.N. 129Furring Channel
Rondo P.N. 127Top Cross Rail
Corner Beadif required
Galvanised Anglepop rivetted toTop Cross Rail
Pop rivet
Pop rivet
1 layer of 10mm or 13mmBoral Plasterboard StandardCore or 10mm Boral Unispanas required
1 layer of 10mm or 13mmBoral Plasterboard StandardCore or 10mm Boral Unispanas required
Typical Perimeter Details
Rondo P.N. 127 TopCross Rail
Rondo P.N. 139 Joiner
Rondo P.N. 129Furring Channel
1 layer of 10mm or 13mmBoral Plasterboard StandardCore or 10mm Boral Unispanas requiredWall angle trim
Rondo P.N. 127 TopCross Rail
Rondo P.N. 139 Joiner
1 layer of 10mm or 13mmBoral Plasterboard StandardCore or 10mm Boral Unispanas required
Boral PlasterboardCornice
Rondo P.N. 129Furring Channel
Typical Perimeter and Bulkhead Details
48
Non Fire-rated Ceiling Systems
49
QuietZone™ Ceiling Systems
1. Screw fix the mount via the central hole in the rubber element. For fire-rated ceilings, a 25 mm diameter x 2 mm steel washer is required under the fastener head.
2. Use a suitable power tool with an appropriate hex driver and tighten the fastener to a point where there is no compression of the rubber element. Check the pull-out capacity of fastener to ensure correct size is selected.
3. Clip furring channel into the Furring Channel Clip.
CeilingSupport Structure
FurringChannel Clip
Rubber Elementshowing colourcoding dot
Fixing Screw (with25mm dia. Steelwasher wherefire rating required)
RondoFurring Channel
IntroductionThe QuietZone™ systems have been designed to reduce unwanted noise from specific areas of a home. There are three QuietZone™ ceiling systems designed to suit varying budgets and design considerations - these three systems are identified as "Quiet", "Quieter" and "Quietest".
Building a QuietZone™ ceiling requires a little more care and attention to detail than standard systems. Each component in a QuietZone™ System must be securely fixed, necessary services strategically placed and all plasterboard perimeter edges and openings adequately sealed.
Note: QuietZone™ is a registered trademark of Amatek Limited trading as Insulation Solutions.
Boral Acoustic Ceiling MountThe Boral Acoustic Ceiling Mount is used in the QuietZone™ systems and provides a cost effective solution to impact sound insulation for ceilings direct fixed or suspended to either concrete soffits, timber floor joists, roof purlins and the like.
The Acoustic Ceiling Mount significantly reduces transmission of impact sound from many common sources including:
• footfalls;• rain; and• equipment
Other typical applications for the Boral Acoustic Ceiling Mount are in multi-residential apartment construction, cinemas, and areas below a plant room.
Advantages• Easy and quick to install;• Suspended application does not need
additional fixings;• Acoustic Ceiling Mount can be slid along
the top cross rail which allows for easy re-positioning;
• Minimises low frequency “thumps” generated from footfalls on timber floors;
• Fully tested;• Rubber Element is colour coded for easy
identification of load range; and• High load capacity minimises number of
Acoustic Ceiling Mounts required per square metre.
InstallationThe Boral Acoustic Ceiling Mount is designed for use in Rondo's Key-Lock Ceiling Suspension System. Refer to the Rondo catalogue for the spanning and spacing options for furring channels and primary rails.
Direct Fix Application
Components• Furring Channel Clip;• Rubber Element; and• Screw (supplied by others):
- 14-10 x min. 65 mm Type 17 roof screw into timber;
- 12 or 14 gauge x min. 45 mm drill point roofing screw into light gauge steel; or
- “Tapcon” screw into concrete.
ProcedureAssemble the mount as shown in the following illustration.
Introduction
50
QuietZone™ Ceiling Systems
51
QuietZone™ Ceiling Systems
Suspended Application
Components
• Furring Channel Clip• Interchange Clip• Rubber Element
ProcedureAssemble the mount as shown in the following illustration.
RondoTop Cross Rail
FurringChannel Clip
Rubber Elementshowing colourcoding dot
RondoFurring Channel
Interchange Clip
1. Clip the Interchange Clip into the Top Cross Rail.2. Clip furring channel into the Furring Channel
Clip.
PerformanceThe Boral Acoustic Ceiling Mount has been acoustically tested for airborne and impact sound insulation in both the direct fix and the suspended application. Acoustic ratings for the assembly details illustrated below are shown in the following table.
Load RatingsFor both applications, the rubber element comes in a variety of load bearing capacities and is colour coded accordingly. The appropriate element must be used to support the weight of plasterboard being used in the ceiling.
As each layer of plasterboard is fixed to the furring channel, the rubber element will deflect under the load. A maximum deflection of 5 mm will result when the maximum load, as indicated in the following table, is reached. Allowance should be made for deflection when setting out ceiling heights.
Acoustic Ceiling Mount
ColourCoding
Max. Load in kg
Static Deflection
Blue dotWhite dot
1725
5mm5mm
Direct to joist
Plasterboard Fixing Floor Covering Rw IIC
Bare
Bare
Bare
Carpet and underlay
Carpet and underlay
39
57
57
57
57
32
54
82
55
81Suspended via Boral
Acoustic Ceiling Mount
Suspended via BoralAcoustic Ceiling Mount
Direct via BoralAcoustic Ceiling Mount
Direct via BoralAcoustic Ceiling Mount
19mm thick chipboardfloor sheeting
190 x 45mm F7 timberjoists @ 450mm centres
Boral Acoustic CeilingMount direct fixed to orsuspended from joists
Furring Channel clippedinto Acoustic Ceiling Mount@ 600 mm max. centres
Two layers 16mm BoralFirestop plasterboardfixed to furring channel
ACI R2.5 glasswoolblanket
Assembly DetailsFRL 60/60/60
Note: An FRL 90/90/90 system is also available using 2 layers of enhanced firegrade plasterboard.Contact your Boral Plasterboard Sales Office for details.
50
QuietZone™ Ceiling Systems
51
QuietZone™ Ceiling Systems
Acoustic Selector
QZ4*
System Number andAssembly Details
Floor Covering
RatingWith Insulation
Rw IIC
Insulation
44
62
44
(AO100)
(AO100)
(AO100)
50
50
50
(AO100)
(AO100)
(AO100)
(Test Ref.)
Floor/Ceiling Depthmm
A bare floor (A) or with a covering of carpet and underlay (B) or with ceramic tiles on cement sheet (C) - on 190mm x 35mm timber floor joists
@ 450mm or 600mm centres. Furring channel fixed with "blue dot" Acoustic Ceiling Mounts(1) to underside of every third joist spaced at 450mm or every second joist spaced at 600mm. 1 layer of 10mm Boral Plasterboard SoundStop™screw fixed to furring channel. Insulation in floor/ceiling cavity. Joints finished. Perimeters acoustically sealed.
A
B
C
287
A
B
C
297
A
B
C
297
* The Impact Insulation Class (IIC) shown as a single number representing impact insulation.(1) Resilient channel, at 450mm centres directly fixed to underside of joists, may be used instead of furring channel
fixed with acoustic ceiling mounts. Use of resilient channel will result in lower Rw and IIC ratings.
49
68
49
(AO100)
(AO100)
(AO100)
54
54
54
(AO100)
(AO100)
(AO100)
54
74
54
(AO100)
(AO100)
(AO100)
59
59
59
(AO100)
(AO100)
(AO100)
A bare floor (A) or with a covering of carpet and underlay (B) or with ceramic tiles on cement sheet (C) - on 190mm x 35mm timber floor joists
@ 450mm or 600mm centres. Furring channel fixed with "blue dot" Acoustic Ceiling Mounts(1) to underside of every third joist spaced at 450mm or every second joist spaced at 600mm. 2 layers of 10mm Boral Plasterboard SoundStop™- first layer screw fixed to furring channel, second layer adhesive/screw fixed to first layer. Insulation in floor/ceiling cavity. Joints finished. Perimeters acoustically sealed.
A bare floor (A) or with a covering of carpet and underlay (B) or with ceramic tiles on cement sheet (C) - on 190mm x 35mm timber floor joists @
450mm or 600mm centres. 2 layers of 10mm Boral Plasterboard SoundStop™ to underside of floor between joists and held in place with cleats nailed to side of joists. Furring channel fixed with "blue dot" Acoustic Ceiling Mounts(1) to underside of every third joist spaced at 450mm or every second joist spaced at 600mm. 2 layers of 10mm Boral Plasterboard SoundStop™- first layer screw fixed to furring channel, second layer adhesive/screw fixed to first layer. Insulation in floor/ceiling cavity. Joints finished. Perimeters acoustically sealed.
A B C
A B C
A B C
Quiet Ceiling System
Quieter Ceiling System
Quietest Ceiling System
75 mm Noise Control Batts (glass wool @ nominal 14 kg /m3)
75 mm Noise Control Batts (glass wool @ nominal 14 kg /m3)
75 mm Noise Control Batts (glass wool @ nominal 14 kg /m3)
QZ5
QZ6
52
QuietZone™ Ceiling Systems
53
QuietZone™ Ceiling Systems
Quiet CeilingsThe "Quiet" ceiling system consists of one sheet of 10mm Boral Plasterboard SoundStop fixed to underside of floor/ceiling joists with Furring Channel (Rondo P.N.129) and Boral Plasterboard Acoustic Ceiling Mount.
• Fix Furring Channel to ceiling joists at 450mm centres.• For joists at 450mm centres, fix ceiling mount to every third joist. For joists at 600mm centres, fix
ceiling mount to every second joist. • Conventionally fasten single layer of Boral SoundStop to Furring Channel with combination stud
adhesive and supplementary fasteners. Apply stud adhesive at 230mm max. centres across sheet width, 200mm from edges of sheets and screw points. Screw fasten plasterboard at sheet edges(10-16mm from edge) and along centreline of sheet to each Furring Channel.
• Floor/ceiling cavity is filled with 75mm noise control batts.
QuietZone™ performance• Rw 50 - Loud speech can be heard but not understood.• IIC 62 - With floor covering of carpet and underlay, walking is heard as low thump.
QuietZone™ Installation
Flooring
Floor joists
75mm Noise Control BattsTM
For ceiling joists @ 450mm centres, fix ceiling mount to every third joist.For joists @ 600mm centres, fix ceiling mount to every second joist.
One layer of BoralPlasterboard SoundStopconventionally fixed to Furring Channels
52
QuietZone™ Ceiling Systems
53
QuietZone™ Ceiling Systems
Quieter CeilingsThe "Quieter" ceiling system consists of two sheets of 10mm Boral Plasterboard SoundStop fixed to underside of floor/ceiling joists with Furring Channel (Rondo P.N.129) and Boral Plasterboard Acoustic Ceiling Mount.
• Fix Furring Channel to ceiling joists at 450mm centres.• For joists at 450mm centres, fix ceiling mount to every third joist. For joists at 600mm centres, fix
ceiling mount to every second joist.• Mechanically fasten first layer of Boral SoundStop to Furring Channel with screws across sheet width
at 300mm max. centres.• Second layer is fixed to first using combination stud adhesive and mechanical fasteners. Apply stud
adhesive at 230mm max. centres across sheet width, 200mm from edges of sheets and screw points. Screw fasten plasterboard at sheet edges (10-16mm from edge) and along centreline of sheet to each Furring Channel.
• Floor/ceiling cavity is filled with Insulation Solutions’ 75mm Noise Control Batts™.
QuietZone™ performance• Rw 54 - Very hard to hear loud speech.• IIC 68 - With floor covering of carpet and underlay, heavy walking heard as low thump.
QuietZone™ Installation
FlooringFloor joists
75mm Noise Control BattsTM
For ceiling joists @ 450mm centres, fix ceiling mount to every third joistFor joists @ 600mm centres, fix ceiling mount to every second joist
300mm min overlap
Screw along centrelineof sheet
Second layer ofBoral Plasterboard SoundStop
First layerof Boral PlasterboardSoundStop screw fastened toFurring Channels
Daubsacross width of sheetat Furring Channel locations
of Stud Adhesive
54
QuietZone™ Ceiling Systems
55
QuietZone™ Ceiling Systems
QuietZone™ Installation
Quietest CeilingsThe "Quietest" ceiling system consists of two sheets of 10mm Boral Plasterboard SoundStop fixed to underside of floor/ceiling joists with Furring Channel (Rondo P.N.129) and Boral Plasterboard Acoustic Ceiling Mount. Two additional layers of 10mm Boral Plasterboard SoundStop are fixed to underside of flooring with cleats, ensuring a snug fit between joists.
• Fix Furring Channel to ceiling joists at 450mm centres.• For joists at 450mm centres, fix ceiling mount to every third joist. For joists at 600mm
centres, fix ceiling mount to every second joist. • Fasten two layers of 10mm Boral Plasterboard SoundStop to underside of flooring with
cleats.• Mechanically fasten first layer of Boral SoundStop to Furring Channel with screws across
sheet width at 300mm max. centres.• Second layer is fixed to first using combination stud adhesive and mechanical fasteners.
Apply stud adhesive at 230mm max. centres across sheet width, 200mm from edges of sheets and screw points. Screw fasten plasterboard at sheet edges (10-16mm from edge) and along centreline of sheet to each Furring Channel.
• Floor/ceiling cavity is filled with Insulation Solutions’ 75mm Noise Control Batts™.
QuietZone™ performance• Rw 59 - Loud speech cannot be heard.• IIC 74 - With floor covering of carpet and underlay, heavy walking heard as very low thump.
Flooring
Floor joists
75mm Noise Control BattsTM
2 x 10mm layers ofBoral Plasterboard SoundStopto underside of flooring.Hold in place with plasterboardcleats nailed to side of floor joists
For ceiling joists @ 450mm centres, fix ceiling mount to every third joistFor joists @ 600mm centres, fix ceiling mount to every second joist
300mm min overlap
Second layer ofBoral Plasterboard SoundStop
First layer ofBoral Plasterboard SoundStopscrew fastened to Furring Channels
Stud Adhesive daubsacross width of sheetat Furring Channel locations
Screw along centrelineof sheet
54
QuietZone™ Ceiling Systems
55
QuietZone™ Ceiling Systems
www.boral.com.au
Western Australia53 Attwell Street Landsdale 6065Telephone (08) 9400 2666Fax (08) 9302 1133
ACT7 Barrier Street Fyshwick 2609Telephone (02) 6280 4243Fax (02) 6280 5816
Tasmania93 Albert Road Moonah 7009Telephone (03) 6278 9966Fax (03) 6278 9865
Northern TerritoryCnr Coonawarra Road & Mataram Street(PO Box 38245) Winnellie 0820Telephone (08) 8984 4484Fax (08) 8984 3778
Queensland733 Nudgee Road Northgate 4013
Telephone (07) 3215 2244Fax (07) 3215 2299
New South Wales3 Thackeray Street Camellia 2142
Telephone (02) 9638 0571Fax (02) 9638 5557
South Australia119-121 Bedford Street Gillman 5013
Telephone (08) 8240 8888Fax (08) 8341 1004
Victoria676 Lorimer Street Port Melbourne 3207
Telephone (03) 9214 2138Fax (03) 9646 1912
Export Department676 Lorimer Street
Port Melbourne 3207Telephone (03) 9214 2138
Fax (03) 9646 1109
GuaranteeProducts manufactured and supplied by Boral Australian Gypsum Limited (BAGL) A.C.N. 004 231 976, trading as Boral Plasterboard, are guaranteed to be of consistent quality and free from any defects.
Boral Plasterboard products must be installed using the components and accessories specified and in accordance with the instructions detailed in Boral Plasterboard’s technical literature.
Our products are manufactured to suit the requirements of the building industry in Australia.
Boral Plasterboard may limit its liability under this guarantee to, at its option, the replacement or paymentof the cost of replacing OR supplying equivalent or payment of the cost of supplying equivalent OR therepair or payment of the cost of repairing products found to be defective.
Important NoteThe technical information contained within this manual was correct at the time of printing. Building Systems and details are, however, subject to change. To ensure the information you are using is current, Boral Plasterboard recommends you review the latest building information
© Boral Australian Gypsum limited 2001
available electronically on TecSYS (our technical catalogue on CD) or the Boral Plasterboard Website. Alternatively, contact your nearest Boral Plasterboard Sales Office or TecASSIST (see details below).
Through TecASSIST Boral Plasterboard is demonstrating its commitment to providing excellent technical service and support to design, building and construction professionals Australia wide.
A free-call architectural support line, TecASSIST is available to provide sound advice on all matters relating to drywall plasterboard construction.
Combining years of professional experience with the latest design information and technology, the TecASSIST team has the skills to help you.
Boral Plasterboard TecASSIST phone line is open to receive calls from 8:30am to 4:30pm Monday to Friday, Melbourne time (Victorian public holidays excepted).
FREE-CALL 1800 811 222
24 hour fax: (03) 9645 1812email: [email protected].