Vacuum science... product solution.
Edwards CDX1000 represents the next generation of dry pump technology. The CDX1000 is a double-ended screw mechanism for the chemical process, pharmaceutical and petrochemical industries.
• Performanceͳ Continuousfromatmospheretoultimateͳ Excellenttemperaturecontrolͳ Largeliquidslugcapability
• Environmentͳ Noeffluentgeneratedͳ Dryrunningmechanismͳ Efficientsolventrecoveryͳ Lowpower
• Maintenanceͳ On-sitesealandbearingchangeͳ Flushablewithwater,solventorsteamͳ Lowrotationalspeedͳ Cooledandfilteredoilͳ Integralaccessorymodules
ThisinnovativetechnologyleveragesEdwardslatestmanufacturinganddesignphilosophies.TheCDX1000issuitedtolargerprocesseswhererepeatabilityandreliabilityarekey.Technologiesandmanufacturingtechniqueshavebeencarefullyselectedtoproducearobust,highperformancemachinethatissimpletooperateandmaintain.
• Simplicityͳ Lowpartscountͳ Balancedrotordesignͳ Nocompressionplateͳ Industrystandardmotors
CDX1000 dry vacuum pump
Features and benefits
product datasheet
Performance with reliability
• OutstandingtemperaturecontrolwithEdwardsstandardindirectcoolingͳ Processrepeatabilityͳ Protectspumpfromthermalshockandcorrosion
• Excellentliquidhandlingͳ Nocompressionplate=nohydrauliclockͳ Selfdrainingmechanism
• Dustandparticulatetolerantͳ Noexpansionvolumesͳ Nocoldseizures
• Extendedmaintenanceperiodͳ Cooledandfilteredoilsystem
• Nocomplexcontrolsͳ Directon-linestart
Simple, rugged design
Arobustmechanismforreliable,repeatableperformance
• Double-ended,variablepitchscrew• Patentedstatormachiningremovestheneedforaheadplate• Nocompressionplate• Minimalpartscount• Standardmotors• Nocoatings• Lowrotationalspeed
Pump is runningtoo cold
Pump is running too hot
Vapor Decomposition& Auto-ignition
Optimumoperatingconditions
Pre
ssu
re
Temperature
Condensation, Corrosion & Polymerisation
compressionin2smallervolumes
lessheatgeneratedcloser tolerances
tighter temperature control
Systemsiation tailored to match your process needs
• Lowcost,pre-engineeredmodules• Customisedsystems• Tailoredapplicationssupport
ͳ Avoidproblemsͳ Solveissuesiftheyarise
• Applicabletoawiderangeofprocessesͳ Matchperformancetoprocessͳ Monitoringandcontroloptionsͳ Dust,hardparticleandliquidcarry-over protection
Maintainability
TheCDX1000isdesignedtominimisescheduleddown-timefromlinemaintenancetooverhaul.
• Minimisedprocesslinedisturbanceͳ Integralflamearrestorscanbecleanedandinspectedwithoutbreakingprocesslines
ͳ Silencersaredrainableandcleanable• Standardautomotivestyleoilfilters• Bearingandsealchangeispossibleon-site• Recoveryphilosophyminimisespumpremoval
ͳ Clearancesopenuponcooling;nocoldseizures• Rotorsdonotrequirecostlyre-coating• Rotorsarenotassembledasmatchedpairs
Cool and clean
Thebearingsandrotorstubshaftsarefedcooled,filteredoil.Limitingtheoiltemperaturepreventscarburisationanddegradation.
• Extendedbearingandseallife
Applicable to a wide range of processes and industries
Processes
• Distillation• Drying• Evaporation/crystallisation• Solvent/vapourrecovery• Filtration• Sterilisation• Central/housevacuum
Industries
• Plastics• Fattyacides,alcoholsandamines• Adhesives,paintsandcoatings• Medical(EthyleneOxide)• Edibleoils• Silicones• Basicchemicals
Oil coolers on the secondary water circuit prevents silting or furring.
Technical specification
Units 50Hz 60HzMaximumpumpingspeed m3h-1 900
ft3min-1 530Capacityat10mbar(7.5Torr) m3h-1 900
ft3min-1 530Ultimatevacuum mbar 0.005
Torr 0.004Maximumbackpressure-standard(optional*) mbarA 1150
psig 2.0Powerconsumptionat10mbar(7.5Torr) kW 17.1
hp 23.2Standardmotor(380-400V,3ph,50Hz) kW 30Standardmotor(200-460V,3ph,60Hz) hp 40Coolingwaterflowrate,(adjustable) lmin-1 10-20
galmin-1 2.64-5.28Coolingwatersupplytemperaturerange 5-35°C 41-95°FCoolingwatersupplypressure barg 2-10
psig 29-145Sealpurgeflow(maximum),regulatedto0.3-0.5barg,(5-7psig) lmin-1 24
ft3min-1 0.85Sealpurgesupplypressure,(minimum-maximum) barg 2-10
psig 29-145Noise(max.withexhaustsilencer) dB(A) 82Weight(withframeandstandardmotor) kg 1710 1705
lbs 3765 3745Processconnection,inlet ANSI/DIN 6”/DN150Processconnection,outlet ANSI/DIN 3”/DN80Pumpingmechanism Variablepitchedscrew
* Consult Edwards
Performance curve
Speed (m3/hr) Power (kW)
Spee
d (m
3/hr
)
Pressure (mbar)
Pow
er (
kW)
0.0
100.0
900.0
800.0
700.0
600.0
500.0
400.0
300.0
200.0
1000.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
0.001 0.01 0.1 1 10 100 1000
Dimensions - mm (inch)
Note:ThisdiagramshowsaCDXwithintegralflamearrestors.
ASideviewBPlanviewCEndviewDFrontfixingdimensionswithmountingfeetremoved
1.Pumpinlet2.Pumpoutlet3.Fixing-holes:Ø18mm(0.71inch),2holesoneachmountingfoot4.Fixing-holes:Ø17mm(0.67inch),2holesoneachmountingbracket
*Maximum
Systemisation
Becausenotwoinstallationsareidentical,Edwardsoffersacustomsystemisationdesignandbuildservice,exactlymatchedtocustomerneeds,usingpre-engineeredmodulestogetherwithanextensiveCADcapability.Thisalsoallowssubsequentexpansionorreconfiguration.Awiderangeofmodulesisavailable,including:
• EH*andHVmechanicalboosterpumps
• Condensers• Receivers• Knockoutpots• Dustfilters• Solventpurging• Flamearrestors• Isolationandthrottlecontrolvalves• Instrumentation• Silencers• Inverterdrivesandpressurecontrols• Electricalcontrolpanels• Airblastclosed-loopcooling• Documentation• Baseskids
Therequirementfortheseorotheraccessoriesisclarifiedthroughexpertapplicationsengineering.
Workcanbecarriedouttoacustomer’sspecifications,ortolocalorindustrystandardcodesandpractices.Fulldocumentationisprovided,andfullcertificationcanbeobtainedifnecessary.
* Edwards EH Series boosters feature our unique hydokinetic drive which provides significant cost and performance advantages over direct drive machines. The hydrokinetic drive removes any need for pressure sensors or bypass lines or inverters, and allows the booster to run from atmospheric pressure to ultimate vacuum, giving faster pumpdown and more flexible operation with less maintenance.
• Pre-engineeredmodules• Customisedsystems• Tailoredapplicationssupporttomatch
performancetoprocess
CDX1000+HV8000boostercombination
HV8000
CDX1000
Systemisation to match your process
Dimensions - CDX + EH2600 combination16
62 1570
230
328.5
12
~18
50
220220
703
222
AS/
1471
/A
~2500810
209
~12
50
1
2
3
4
Performance - CDX + EH/HV combinations
0
2000
10-3 10-2 10-1 1 10 100 760
0
2000
4000
6000
1000
3000
5000
7000
10-3 10-210-4
10-2
10-1 1 10 100 1000
10-1 1 10+1 10+2 10+3 10+4 10+5
CDX1000 + Booster combinations
Pa
mbar
Torr
4000
1000
3000
Spe
ed ft
³/min
-1
Spe
ed m
³/h -1
EH2600 (50Hz)
EH2600 (60Hz)
EH4200 (50Hz)
EH4200 (60Hz)
HV8000 (50Hz)
HV8000 (60Hz)
Global contacts
EUROPEUK Crawley+441293528844UK (local rate)08459212223BelgiumBrussels+3223000730FranceParis+33141211256GermanyMunich08000001456ItalyMilan+3902484471
USANiagara (toll free)+18008489800BRAZILSao Paulo+551139525000ISRAELQiryat-Gat+97286810633
ASIA PACIFICChina (toll free)+864001119618India,Pune+912040752222Japan,Yachiyo+81474588831Korea,Bundang+82317167070Singapore+6565468408Taiwan R.O.C.JhunanTown+88637581000
Standard system dimensions - mm (inch)
CDX+EH4200Combination
~2500810
209
~10
50
1
1604
1512
12
230
328.5
~18
00
2
3
3
220703 22
2A
S/14
70/A
CDX+HV8000Combination
~2500
~20
50
810209
~12
50
1904
1812
12230
328.5
3
4
2
1
222
703220
220
3
AS/
1472
/A
PublicationNumber:A70820895,IssueB©EdwardsLimited2013.Allrightsreserved.