2
Installation Instructions t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada Copyright © MP Lighting. All technical information in this document is subject to change. 01-2011 L104 S CLICK End Cap Screws 1 Mount standoffs and power canopy to ceiling. Please refer to instructions for Cable or Rod stand-off suspension set (SDF060/ 61) and Flexible Power Canopy (CPY054/ 55). 3 4 Fasten end-caps into C-shaped screw channels in both sides of circuit board rail. Tighten screws with Allen Key. Push in jack connector on Flexible Power Canopy (CPY054/ 55) into end-cap and thread cap until secure. Maintenance Clean with a soft cloth. Parts Qty. • LED rail • Cross countersunk screws End-caps 1 8 2 Tools Phillips screwdriver not included • Read all instructions. • WARNING: RISK OF FIRE OR ELECTRICAL SHOCK: Do not make or alter any openings in the compartment of wiring or electrical components during installation. Do not alter or add ballasts, or any other electrical components. • Installation and use of this fixture mounting assembly requires a person familiar with the construction and operation of luminaire electrical systems and the hazards involved, if not qualified, do not attempt installation. • Turn off power before installation. • Connect to appropriate 24V DC constant current driver only. • Do not over tighten screws. • Do not spray water on fixture during cleaning. Avoid using detergents with hand softeners, anti-bacterial agents, glass cleaners or acrylic cleaning products. • KEEP THESE INSTALLATION INSTRUCTIONS. CAUTION Push LED rail into clamp until rail snaps into place. Rail can slide along clamps into desired position. Tighten locking screws on all clamps when in place. 2 Jack Connector Cap Lock screw SDF060 CPY054 Clamp LED Rail

CAUTION - MP LIGHTING · 2014. 3. 20. · L104S CLICK End Cap Screws 1 Mount standoffs and power canopy to ceiling. Please refer to instructions for Cable or Rod stand-off suspension

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CAUTION - MP LIGHTING · 2014. 3. 20. · L104S CLICK End Cap Screws 1 Mount standoffs and power canopy to ceiling. Please refer to instructions for Cable or Rod stand-off suspension

InstallationInstructions

t 1.877.708.1184 f 604.708.1185 www.mplighting.com16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada

Copyright © M

P Lighting. All technical information in this docum

ent is subject to change.01-2011

L104SCLICK

End Cap

Screws

1 Mount standoffs and power canopy to ceiling. Please refer to instructions for Cable or Rod stand-off suspension set (SDF060/ 61) and Flexible Power Canopy (CPY054/ 55).

34

Fasten end-caps into C-shaped screw channels in both sides of circuit board rail. Tighten screws with Allen Key.

Push in jack connector on Flexible Power Canopy (CPY054/ 55) into end-cap and thread cap until secure.

MaintenanceClean with a soft cloth.

Parts Qty.• LED rail• Cross countersunk screws • End-caps

18

2

Tools• Phillips screwdriver not included

• Read all instructions.

• WARNING: RISK OF FIRE OR ELECTRICAL SHOCK: Do not make or alter any openings in the compartment of wiring or electrical components during installation. Do not alter or add ballasts, or any other electrical components.

• Installation and use of this fixture mounting assembly requires a person familiar with the construction and operation of luminaire electrical systems and the hazards involved, if not qualified, do not attempt installation.

• Turn off power before installation.

• Connect to appropriate 24V DC constant current driver only.

• Do not over tighten screws.

• Do not spray water on fixture during cleaning. Avoid using detergents with hand softeners, anti-bacterial agents, glass cleaners or acrylic cleaning products.

• KEEP THESE INSTALLATION INSTRUCTIONS.

CAUTION

Push LED rail into clamp until rail snaps into place. Rail can slide along clamps into desired position. Tighten locking screws on all clamps when in place.2

Jack Connector

CapLock screw

SDF060

CPY054

Clamp

LED Rail

Page 2: CAUTION - MP LIGHTING · 2014. 3. 20. · L104S CLICK End Cap Screws 1 Mount standoffs and power canopy to ceiling. Please refer to instructions for Cable or Rod stand-off suspension

InstallationInstructions

t 1.877.708.1184 f 604.708.1185 www.mplighting.com16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada

Copyright © M

P Lighting. All technical information in this docum

ent is subject to change.01-2011

L104WCLICK

End Cap

Screws

1 Mount wall standoffs and power canopy. Please refer to instructions for Fixed-angle wall mount stand-off (SDF070) and Flexible Power Canopy (CPY054/ 55).

34

Fasten end-caps into C-shaped screw channels in both sides of circuit board rail. Tighten screws with Allen Key.

Push in jack connector on Flexible Power Canopy (CPY054/ 55) into end-cap and thread cap until secure.

MaintenanceClean with a soft cloth.

Parts Qty.• LED rail• Cross countersunk screws • End-caps

18

2

Tools• Phillips screwdriver not included

• Read all instructions.

• WARNING: RISK OF FIRE OR ELECTRICAL SHOCK: Do not make or alter any openings in the compartment of wiring or electrical components during installation. Do not alter or add ballasts, or any other electrical components.

• Installation and use of this fixture mounting assembly requires a person familiar with the construction and operation of luminaire electrical systems and the hazards involved, if not qualified, do not attempt installation.

• Turn off power before installation.

• Connect to appropriate 24V DC constant current driver only.

• Do not over tighten screws.

• Do not spray water on fixture during cleaning. Avoid using detergents with hand softeners, anti-bacterial agents, glass cleaners or acrylic cleaning products.

• KEEP THESE INSTALLATION INSTRUCTIONS.

CAUTION

Push LED rail into SDF070 until rail snaps into place. Rail can slide along clamps into desired position. Tighten locking screws on all standoffs when in place.2

Jack Connector

Cap

Lock screw

SDF070

CPY054

LED Rail