Room Controller with CO2 Sensor 3
CO2 Sensor 4
F7 Filter 400 x 220 x 48 mm 5
Carbon Filter 6
Design valve circle 7(for pipes Ø 100, 125 and 160)
Design valve square 8(for pipes Ø 100, 125 and 160)
Wall Grill Cover, white 216 x 174 9(circular holes Ø 10)
Wall Grill Cover, white 216 x 174 10(circular holes Ø 5)
Wall Grill Cover, white 216 x 174 11(square holes 10 x 10)
Wall Grill Cover, white 216 x 174 12(square holes 5 x 5)
Floor Grid - Steel 13
Ceiling/Wall Grill 14
Ceiling or Wall Air Diffuser - Plastic Ø 125mm 15(version also for Ø 100, Ø 150, Ø 200)
Facade Box 16
Doubled Facade Box Vertical - Upper 17
Double Facade Box Vertical - Lower 18
Doubled Facade Box Horizontal - Left 19
Doubled Facade Box Horizontal - Right 20
EPP Pipe System 21
Flexible Plastic Pipe DN 90/DN 75 AB 22
Flexible Plastic Pipe DN 90/DN 75 23
Flexible Pipe Connector Ø 90 24(version also for Ø 75)
Distribution Box 1 x 150/6 x 90 25
Distribution Box 1 x 150/8 x 90 26
Distribution Box 1 x 150/12 x 75 27
Distribution Box 1 x 150 (350 x 350)/12 x 90 28(version also for 1 x 150 (300 x 300)/12 x 75)
Distribution Box Direct Single Row 1 x 150/8 x 90 29
Distribution Box Direct Single Row 1x 150/10 x 90 30
Distribution Box Direct Double Rowed 1 x 150/8 x 90 31
Distribution Box Direct Double Row 1 x 150/10 x 90 32
Air Flow Control Valve Ø 90 33(version also for Ø 75)
Register Boot Straight 90/125 34(version also for 75/125)
Register Boot Straight 2 x 75/250 x 100 35
Register Boot 1 x 90/250 x 100 36
Register Boot 2 x 90/250 x 100 37(version also for 2 x 75/250 x 100)
Register Boot Straight 1 x 90/250 x 100 38
Register Boot - Plastic 1 x 90/1 x 125 39
Register Boot 1 x 90/1 x 125 40
Register Boot 1 x 90/1 x 125 41with Noise Silencer connected 1 x Ø 100/1400
Register Boot 2 x 90/1 x 125 42(version also for 2 x 75/1 x 125)
Register Boot 2 x 90/1 x 125 43with Noise Silencer connected 2 x Ø 100/1400
Register Boot 2 x 75/1 x 125 44with Noise Silencer connected 2 x Ø 80/1400
Perforated Strap (reel 10 m) 45
Elbow Ø 90/90º 46(version also for Ø 75/90º)
"Y" Shaped Component 90 x 75 x 75 47
Holešovská 1692, 769 01 Holešov, Czech Republic
JABLOTRON LIVING TECHNOLOGY s.r.o.
Tel: +420 775 587 595 | E-mail: [email protected] | Web: JABLOTRONLT.COM
VEN2018/05/2
0 to 5000 ppm (secondary outlet 0-100 %) NDIR (Non-dispersive Infra Red)
±50 ppm, ±3 % of the measured value (defined under conditions of at least 3 completed ACDLs in the preceding 3 weeks), C02 measurement response time (90 %) 90 seconds, warm-up time 2 minutes, ACDL (automatic calibration in dimming light mode), correction of C02 measurement
IP20
CO2 measuring range
CO2 measuring method
CO2 measuring precision
Cover
Technical data
Room Controller with CO2 Sensor
Controller with CO2 Sensor - NDIR C02 Sensor for detection of carbon dioxide content in rooms with variable occupancy
Measuring rangeThe C02 measuring range is 0 ... 5000 ppm. A section of this value is converted using two parameters to 0 ... 100 %, which is then shown on the display, for example 300 ... 2500 ppm is equivalent to 100 ... 0 % (air quality) or 0 ... 100 % (pollution). The Modbus also shows the absolu-te value in ppm. The parameters are set by direct entering in the Modbus registers. The default values are 0 % ... 350 ppm (clean air), 100 % ... 2500 ppm (highest pollution).
Auto-calibrationThe precision of the sensors may be reduced by trans-port vibrations and ageing. During operation, the sensor continuously monitors the minimum measurement and assumes a drop in the C02 concentration to the level of concentration in the outdoor air (400 ppm) at least once every 8 days. The lowest measured value is assig-ned a concentration of 400 ppm. The auto-calibration algorithm does not work in a case where the room is occupied continuously, or no drop in the concentration occurs (for example, greenhouses). In such case, it is possible to deactivate the function by direct entering in the Modbus table. In default settings, auto-calibration is active.
ACCESSORY CODE:
OCO2
0 to 5000 ppm (secondary outlet 0-100 %) NDIR (Non-dispersive Infra Red)
±50 ppm, ±3 % of the measured value (defined under conditions of at least 3 completed ACDLs in the preceding 3 weeks), C02 measurement response time (90 %) 90 seconds, warm-up time 2 minutes, ACDL (automatic calibration in dimming light mode), correction of C02 measurement
IP20
CO2 measuring range
CO2 measuring method
CO2 measuring precision
Cover
Technical data
CO2 Sensor
Room CO2 Sensor - NDIR C02 Sensor for detection of carbon dioxide content in rooms with variable occupancy.
Measuring rangeThe C02 measuring range is 0 ... 5000 ppm. A section of this value is converted using two parameters to 0 ... 100 %, which is then shown on the display, for example 300 ... 2500 ppm is equivalent to 100 ... 0 % (air quality) or 0 ... 100 % (pollution). The Modbus also shows the absolu-te value in ppm. The parameters are set by direct entering in the Modbus registers. The default values are 0% ... 350 ppm (clean air), 100 % ... 2500 ppm (highest pollution).
Auto-calibrationThe precision of the sensors may be reduced by trans-port vibrations and ageing. During operation, the sensor continuously monitors the minimum measurement and assumes a drop in the C02 concentration to the level of concentration in the outdoor air (400 ppm) at least once every 8 days. The lowest measured value is assig-ned a concentration of 400 ppm. The auto-calibration algorithm does not work in a case where the room is occupied continuously, or no drop in the concentration occurs (for example, greenhouses). In such case, it is possible to deactivate the function by direct entering in the Modbus table. In default settings, auto-calibration is active.
ACCESSORY CODE:
SCO2
CharacteristicsThe F7 filter class according to EN 779 for fine dust; the filter is designed for holding particles of size 1 - 3 microns. It is applied to achieve higher indoor quality requirements and is effective against bacteria, cement dust and partly against soot or tobacco smoke.
F7 Filter 400 x 220 x 48 mm
ACCESSORY CODE:
F7F
Carbon Filter
CharacteristicsA Carbon Filter can be added in order to despose gaseous pollutants. The Carbon used inside of the filter eliminates undesireble odors.
ACCESSORY CODE:
CF
Technical sheet
Valve for air intake and outflow
Product description
pipe diameter
body diameter
exterior diameter
body depth
diameter of the valve cap
100 90 137,5 54 170 125 114 156 57 200 160 149 191 57 230
dimensions in mm
Valve intended for attachment to a wall or ceiling for air intake or outflow. Use: New builds, reconstructions, valve replacement. A big advantage of this valve is very easy installation method.
The valve consists of two parts: The body of the valve and the glass front plate.
diam
eter
of t
he v
alve
cap
Body
dia
met
er
exte
rior d
iam
eter
Body depth
CharacteristicsDesign valve AIR DESIGN GLASS from Czech manufacturer SETRITE s.r.o. Valve intended for attachment to a wall or ceiling for air intake or outflow. The valve consists of two parts: the body of the valve and the glass front plate (shape: circle or square). The body of the valve is fitted within a system of piping by three metal springs. The glass front plate is attached to the body of the valve using springs.
Dimensions
Design valve circle (for pipes Ø 100, 125 and 160)
ACCESSORY CODE:
SVK100, SVK125, SVK160
Pipe diameter
Body diameter
Exterior diameter
Body depth
Diameterof the valve cap
100
90
137,5
54
200(170)
125
114
156
57
200
160
149
191
57
230
Color variants - shine Color variants - matt
0627 1013 1586 7000 7013 7016
8815 9003 9005 9007 9010 9115
1001M 1002M 1003M 1004M 1015M 7013M
7016M 8615M 8815M 9003M 9005M 9010M
Technical sheet
Valve for air intake and outflow
Product description
pipe diameter
body diameter
exterior diameter
body depth
diameter of the valve cap
100 90 137,5 54 170 125 114 156 57 200 160 149 191 57 230
dimensions in mm
Valve intended for attachment to a wall or ceiling for air intake or outflow. Use: New builds, reconstructions, valve replacement. A big advantage of this valve is very easy installation method.
The valve consists of two parts: The body of the valve and the glass front plate.
diam
eter
of t
he v
alve
cap
Body
dia
met
er
exte
rior d
iam
eter
Body depth
CharacteristicsDesign valve AIR DESIGN GLASS from Czech manufacturer SETRITE s.r.o. Valve intended for attachment to a wall or ceiling for air intake or outflow. The valve consists of two parts: the body of the valve and the glass front plate (shape: circle or square). The body of the valve is fitted within a system of piping by three metal springs. The glass front plate is attached to the body of the valve using springs.
Design valve square (for pipes Ø 100, 125 and 160)
ACCESSORY CODE:
SVC100, SVC125, SVC160
100
90
137,5
54
200(170)
125
114
156
57
200
160
149
191
57
230
Color variants - shine Color variants - matt
0627 1013 1586 7000 7013 7016
8815 9003 9005 9007 9010 9115
1001M 1002M 1003M 1004M 1015M 7013M
7016M 8615M 8815M 9003M 9005M 9010M
Dimensions
Pipe diameter
Body diameter
Exterior diameter
Body depth
Diameterof the valve cap
Wall Grill Cover, white 216 x 174(circular holes Ø 10)
The final design can be modified on demand (stainless steel colour
according to the RAL colour swatch)
ACCESSORY CODE:
MI216174K10
Wall Grill Cover, white 216 x 174(circular holes Ø 5)
The final design can be modified on demand (stainless steel colour
according to the RAL colour swatch)
ACCESSORY CODE:
MI216174K5
Wall Grill Cover, white 216 x 174(square holes 10 x 10)
The final design can be modified on demand (stainless steel colour
according to the RAL colour swatch)
ACCESSORY CODE:
MI216174C1010
Wall Grill Cover, white 216 x 174(square holes 5 x 5)
The final design can be modified on demand (stainless steel colour
according to the RAL colour swatch)
ACCESSORY CODE:
MI216174C55
Ceiling or Wall Air Diffuser - Plastic Ø 125mm(version also for Ø 100, Ø 150, Ø 200)
ACCESSORY CODE:
TVP125
Facade Box
The final design can be modified on demand (stainless steel colour
according to the RAL colour swatch)
ACCESSORY CODE:
FBOX150
Doubled Facade Box Vertical - Upper
The final design can be modified on demand (stainless steel colour
according to the RAL colour swatch)
ACCESSORY CODE:
FBOXSS150HV
Double Facade Box Vertical - Lower
klik
The final design can be modified on demand (stainless steel colour
according to the RAL colour swatch)
ACCESSORY CODE:
FBOXSS150SV
Doubled Facade Box Horizontal - Left
The final design can be modified on demand (stainless steel colour
according to the RAL colour swatch)
ACCESSORY CODE:
FBOXHS150LV
Doubled Facade Box Horizontal - Right
The final design can be modified on demand (stainless steel colour
according to the RAL colour swatch)
ACCESSORY CODE:
FBOXHS150PV
EPP Pipe System
Pipe length:
Outer diameter:
Inner diameter:
1000 mm
210 mm
150 mm
PropertiesThe EPP Pipe System is an innovative, self-supporting system resistant to moisture. It uses a unique connecting principle thanks to which its installation is quick and clean. The pipe system fulfils the requirements of EnEV 2009 for insulation of the air channels in the ventilation system and is installed as a substitute for spiro pipes. The pipe system is available in sizes of DN 150/210. The pipe itself is made of two parts. Thanks to material with a high-density material and thickness of insulation, it has excellent thermal insulation properties.
InstallationInstallation must be done in compliance with the provisions of the building regulations of the given country. The manufacturer’s product warranty is two years, which applies to defective material.
UseUsed for intake of fresh air and extraction of spent air between the outdoor environment and the recuperation unit. It is designed for use in the interior environment. The insulating pipe system is designed for up to 200 Pa and is air-tight. We recommend using max. 375 m3/h. We recommend use of melting wire to shorten the pipe.
Caution: The latch must be installed horizontally. The pipe must have hangers at distances of min. 1 m.
The pipe system is self-supporting according to DIN 4102-1 with material class B2.
ACCESSORY CODE:
EPP
Flexible Plastic Pipe DN 90/DN 75 AB
The PE Flexible Plastic Pipe for HVAC systems built using composite pipe technology according to ČSN 61384-24 ensures transport of air during its exchange with low pressure loss. The inner wall of the pipe has anti-bacterial and anti-fungal protection. Coil 50 m.
The flexible plastic pipe can be used for supply of air to and removal of air from rooms using central devices for control of the ventilation of swelling spaces.
Outer PE-HD layer (green), inner PE-LD layer (transparent or dark grey) + anti-bacterial and anti-fungal additive
PE is resistance to almost all media (alcohols, fats, mineral oils, propellant fuels). The PE structure is disrupted only by high-oxidation acids.
The pipes of given nominal diameters fulfil the requirements of ČSN EN 61384-24. Pressure test 450N. Anti-bacterial test done according to ČSN EN ISO 846:98, method A, C.
Area of application
Pipe material and colour
Chemical resistance
Permits / Standards
Physical characteristics
Dimensions and packaging
Material
E-Module [MPa]
Impact stiffness [kJ/m]
Tensile strength [MPa]
Elongation at break [%]
Specific passage resistance [Ω cm]
Surface resistance [Ω]
Flammability
PE
DIN ISO 527-1/-2
DIN ISO 179-1eU
DIN ISO 527-1/-2
DIN ISO 527-1/-2
DIN IEC 60093
DIN IEC 60093
UL 94
Air supply DN 75Air-flow rate 2 m/s 2,5 m/s 3 m/s 4 m/s
21 m3/h 26,3 m3/h 31,6 m3/h 42 m3/h
DN [mm] Outer diameter [mm] Inner diameter [mm] Packaging [m]
75 75 61 50
90 90 75 50
Air supply DN 90Air-flow rate 2 m/s 2,5 m/s 3 m/s 4 m/s
31,8 m3/h 39,8 m3/h 47,7 m3/h 63,6 m3/h
ACCESSORY CODE:
FLEXIAB
DN [mm] Outer diameter [mm] Inner diameter [mm] Packaging [m]
75 75 61 50
90 90 75 50
Flexible Plastic Pipe DN 90/DN 75
The PE flexible plastic pipe for HVAC systems built using composite pipe technology according to ČSN 61384-24 ensures transport of air during its exchange with low pressure loss. The inner wall of the pipe has anti-bacterial and anti-fungal protection. Coil 50 m.
The flexible plastic pipe can be used for supply of air to and removal of air from rooms using central devices for control of the ventilation of swelling spaces.
Outer PE-HD layer (blue), inner PE-LD layer (dark grey).
PE is resistance to almost all media (alcohols, fats, mineral oils, propellant fuels). The PE structure is disrupted only by high-oxidation acids.
The pipes of given nominal diameters fulfil the requirements of ČSN EN 61384-24. Pressure test 450N.
Area of application
Pipe material and colour
Chemical resistance
Permits / Standards
Physical characteristics
Dimensions and packaging
Material
E-Module [MPa]
Impact stiffness [kJ/m]
Tensile strength [MPa]
Elongation at break [%]
Specific passage resistance [Ω cm]
Surface resistance [Ω]
Flammability
PE
DIN ISO 527-1/-2
DIN ISO 179-1eU
DIN ISO 527-1/-2
DIN ISO 527-1/-2
DIN IEC 60093
DIN IEC 60093
UL 94
Air supply DN 75Air-flow rate 2 m/s 2,5 m/s 3 m/s 4 m/s
21 m3/h 26,3 m3/h 31,6 m3/h 42 m3/h
Air supply DN 90Air-flow rate 2 m/s 2,5 m/s 3 m/s 4 m/s
31,8 m3/h 39,8 m3/h 47,7 m3/h 63,6 m3/h
ACCESSORY CODE:
FLEXI
Distribution Box 1 x 150 (350 x 350)/12 x 90(version also for 1 x 150 (300 x 300)/12 x 75)
ACCESSORY CODE:
RBBR300300
Setrite s.r.o. phone: +420 602 213 776 Ve Višňovce 21 e-mail: [email protected] 326 00 Plzeň web: www.airdesignglass.cz
Distribution Box Direct Single Row 1 x 150/8 x 90
ACCESSORY CODE:
RBPJ1150890
Setrite s.r.o. phone: +420 602 213 776 Ve Višňovce 21 e-mail: [email protected] 326 00 Plzeň web: www.airdesignglass.cz
Distribution Box Direct Single Row 1x 150/10 x 90
ACCESSORY CODE:
RBPJ11501090
Register Boot 1 x 90/1 x 125with Noise Silencer connected 1 x Ø 100/1400
ACCESSORY CODE:
VKR1901125STH
Register Boot 2 x 90/1 x 125with Noise Silencer connected 2 x Ø 100/1400
ACCESSORY CODE:
VKR2901125STH
Register Boot 2 x 75/1 x 125with Noise Silencer connected 2 x Ø 80/1400
ACCESSORY CODE:
VKR2751125STH