8
7/17/2019 Catalogo de Equipos PROMAX http://slidepdf.com/reader/full/catalogo-de-equipos-promax 1/8  GF-941 20 MHz function generator Frequency range: From 0.2 Hz to 20 MHz Output signals: Sine, triangular, square Functions : Variable symmetry, sweep, triggered “burst”, auxiliary generator, AM/FM modulation  GF-230, GF-232 1 MHz & 2 MHz function generators Frequency range: Up to 1 or 2 MHz (GF-232) Signal : Sine, triangular and square (GF-232 generates also pulse wave) GF-232: Frequency counter, level comparator, power amplifier, variable symmetry, TTL output  GB-212 LF generator Frequency range: 20 Hz to 200 kHz, 4 decades Output signals: Sine and square wave Output control: Continuous, attenuator 0 to 60 dB Output meter : E.m.f. sine output wave and the power in dBm and the power in dBm on a 600  FD-252 Double input 2.4 GHz frequency counter Input A: Up to 60 MHz Input B: Up to 2.4 GHz Sensitivity : Up to 10 mV Time base: 10 MHz Resolution: Up to 1 kHz  FD-853 Programmable frequency counter Frequency range: 220 MHz (CH1), 3 GHz (CH2) Sensitivity : Up to -13 dBm Time base: 10 MHz Resolution: 9 digit/sec. Measurements: Period, peak voltage PC connection: RS-232C port or GPIB (optional)  FD-130 Double input 1.3 GHz portable frequency counter Frequency range: 5 Hz - 1.3 GHz Sensitivity : 15 mV RMS / 10 - 50 mV RMS Resolution: 0.0001 MHz - 10 Hz / 1 Hz - 1 kHz Time base: 10 Hz Functions: Selectable gate time, hold, 8 digit display, low pass filter  GF-857 Signal function synthesizer Frequency range: Up to 100 kHz or 30 MHz (according to signal type) Output signals: Sine, triangular, square, ramp Functions: LIN/LOG sweep, arbitrary waves PC connection: RS-232C port or GPIB (optional)  GF-855 Programmable function generator Frequency range: Up to 15 MHz (8 scales) Output signals: Sine, square, triangle, ± ramp, Pulse, AM, FM, Sweep, Trigger, Gate, Burst Functions: LIN/LOG sweep, internal sweep signal output, frequency counter, connection to PC (RS-232C) 1 Please browse our web site to get more information:  www.promax.es TEST & MEASUREMENT CATALOG DIGITAL & ANALOGUE OSCILLOSCOPES FUNCTION GENERATORS FREQUENCY COUNTERS Bandwidth Channels Real-Time Sample Rate Equivalent Sample Rate Record Length Trigger modes USB interface GPIB interface Go/NoGo Output Software for PC Battery Power LCD screen OD-571 OD-576 OD-581 OD-582 OD-590 OD-591 OD-592 Bandwidth Sensitivity Maximum sweep rate Trigger source Trigger modes Coupling Operating modes OD-514B OD-512 40 MHz 20 MHz 1 mV - 5 V/div 5 mV - 5 V/div 0.1 µS/div 0.2 µS/div CH1, CH2, LINE, EXT -  AUTO, NORM AUTO, NORM, TV  AC, HF-REJ, TV, DC AC, TV/H, TV/H CH1, CH2, DUAL (ALT / CHOP), ADD Digital storage oscilloscopes Analogue double-trace oscilloscopes PC connection PC connection 150 MHz 60 MHz 150 MHz 250 MHz 100 MHz 200 MHz 200 MHz 2 2 2 2 2 2 4 100 MS/s 100 MS/s 100 MS/s 100 MS/s 1 GS/s 1 GS/s 1 GS/s 25 GS/s 25 GS/s 25 GS/s 25 GS/s 25 GS/s 25 GS/s 25 GS/s 125 k 125 k 125 k 125 k 25 k 25 k 25 k  Auto, Auto-Level, Normal, Single, TV, Time/Event Delay, Edge, Pulse width Yes Optional Yes Yes Yes, and additional USB for external memory Optional - Optional Optional Optional Optional Optional Yes Optional Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes - - - - Optional Optional Optional B/W B/W Colour Colour Colour Colour Colour  

Catalogo de Equipos PROMAX

Embed Size (px)

DESCRIPTION

Catálogo de equipos

Citation preview

Page 1: Catalogo de Equipos PROMAX

7/17/2019 Catalogo de Equipos PROMAX

http://slidepdf.com/reader/full/catalogo-de-equipos-promax 1/8

GF-941

20 MHz function generator

Frequency range: From 0.2 Hz to 20 MHz

Output signals: Sine, triangular, square

Functions: Variable symmetry, sweep, triggered“burst”, auxiliary generator, AM/FM modulation

GF-230, GF-232

1 MHz & 2 MHz function generators

Frequency range: Up to 1 or 2 MHz (GF-232)

Signal: Sine, triangular and square

(GF-232 generates also pulse wave)

GF-232: Frequency counter, level comparator,

power amplifier, variable symmetry, TTL output

GB-212

LF generator

Frequency range: 20 Hz to 200 kHz, 4 decades

Output signals: Sine and square wave

Output control: Continuous, attenuator 0 to 60 dB

Output meter : E.m.f. sine output wave and the

power in dBm and the power in dBm on a 600 Ω

FD-252

Double input 2.4 GHz frequency counter

Input A: Up to 60 MHz

Input B: Up to 2.4 GHz

Sensitivity: Up to 10 mV

Time base: 10 MHz

Resolution: Up to 1 kHz

FD-853

Programmable frequency counter

Frequency range: 220 MHz (CH1), 3 GHz (CH2)

Sensitivity: Up to -13 dBm

Time base: 10 MHzResolution: 9 digit/sec.

Measurements: Period, peak voltage

PC connection: RS-232C port or GPIB (optional)

FD-130

Double input 1.3 GHz portable frequency counter

Frequency range: 5 Hz - 1.3 GHz

Sensitivity: 15 mV RMS / 10 - 50 mV RMS

Resolution: 0.0001 MHz - 10 Hz / 1 Hz - 1 kHz

Time base: 10 Hz

Functions: Selectable gate time, hold,

8 digit display, low pass filter

GF-857

Signal function synthesizer

Frequency range: Up to 100 kHz or 30 MHz(according to signal type)Output signals: Sine, triangular, square, rampFunctions: LIN/LOG sweep, arbitrary wavesPC connection: RS-232C port or GPIB (optional)

GF-855

Programmable function generator

Frequency range: Up to 15 MHz (8 scales)

Output signals: Sine, square, triangle, ± ramp,

Pulse, AM, FM, Sweep, Trigger, Gate, BurstFunctions: LIN/LOG sweep, internal sweep signal

output, frequency counter, connection to PC (RS-232C)

1Please browse our web site to get more information: www.promax.es

TEST & MEASUREMENT CATALOG

DIGITAL & ANALOGUE OSCILLOSCOPES

FUNCTION GENERATORS

FREQUENCY COUNTERS

Bandwidth

Channels

Real-Time Sample Rate

Equivalent Sample Rate

Record Length

Trigger modesUSB interface

GPIB interface

Go/NoGo Output

Software for PC

Battery Power

LCD screen

OD-571 OD-576 OD-581 OD-582 OD-590 OD-591 OD-592

Bandwidth

Sensitivity

Maximum sweep rateTrigger source

Trigger modes

Coupling

Operating modes

OD-514B OD-512

40 MHz 20 MHz

1 mV - 5 V/div 5 mV - 5 V/div

0.1 µS/div 0.2 µS/div

CH1, CH2, LINE, EXT -

AUTO, NORM AUTO, NORM, TV

AC, HF-REJ, TV, DC AC, TV/H, TV/H

CH1, CH2, DUAL (ALT / CHOP), ADD

Digital storage oscilloscopes

Analogue double-trace oscilloscopes

PC connection

PC connection

150 MHz 60 MHz 150 MHz 250 MHz 100 MHz 200 MHz 200 MHz

2 2 2 2 2 2 4

100 MS/s 100 MS/s 100 MS/s 100 MS/s 1 GS/s 1 GS/s 1 GS/s

25 GS/s 25 GS/s 25 GS/s 25 GS/s 25 GS/s 25 GS/s 25 GS/s

125 k 125 k 125 k 125 k 25 k 25 k 25 k

Auto, Auto-Level, Normal, Single, TV, Time/Event Delay, Edge, Pulse widthYes Optional Yes Yes Yes, and additional USB for external memory

Optional - Optional Optional Optional Optional Optional

Yes Optional Yes Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes Yes

- - - - Optional Optional Optional

B/W B/W Colour Colour Colour Colour Colour

Page 2: Catalogo de Equipos PROMAX

7/17/2019 Catalogo de Equipos PROMAX

http://slidepdf.com/reader/full/catalogo-de-equipos-promax 2/8

FA-363B, FA-376

Basic power supplies 30V, 2 / 5 A

Output: 30V/2A (FA-363B) or 30V/5A (FA-376)

Auxiliary output FA-376: 5V / 1 A

Auxiliary output FA-363B: ± 15V / ± 0.5ADigital displays: Voltage and current

FA-665, FA-662B

Double output 60 V, 5 A power supplies

FA-665: Up to 30V / 5A, 60V / 5A or ± 30V / 5A

FA-662B Up to 30V / 2A, 60V / 1A or ± 30V / 1A

Auxiliary output: 5V / 1A

Digital displays: Voltage and current

FA-851

Programmable DC power supply 32 V, 5 A

Output: 2 x Up to 32V / 2 A

Main output: 6V / 5 A

Auxiliary output: voltage and currentMemory: 100 store/recall sets

Programmable protection: over voltage/current

Remote control: RS-232C and GPIB

EP-613A, FA-325, FA-350, FA-210

BLAUSONIC range power supplies

EP-613A:

3 aux outputs: 5V, 1A / +15V, 0.5A / -15V, 0.5A

Main output: Up to 24V, 3A

FA-325:

2 aux outputs: 5V, 1A / 12V, 1A

Main output: 30V, 2.5A

FA-350:

2 aux outputs: 5V, 0.5A / 12V, 0.5A

Main output: 30V, 5A

FA-210:

Main output: 20V, 10A

FA-405

Programmable power supply 40 V, 5 A

Output: Up to 40V, 5A

PC connection: Serial port (RS-232C)

Digital measurements: Voltage, current, power,

limits, remote control

POWER SUPPLIES

DIGITAL MULTIMETERS

AL-320

32 channels logic analyser

Data acquisition freq: 25 MHz (100 MHz optional)

Trigger level: TTL or variable (optional)

Data memory: 2k words of 32 bits

Reference memory: 2k words of 32 bits

Non volatile memory: 10 acquisition, 10 set-up

PC connection

Availability of disassemblers

LOGIC ANALYSER·

2Please browse our web site to get more information: www.promax.es

PD-755

Oscilloscope mode!

AC / DC Voltage

AC / DC Current

Resistance

Capacitance

Frequency

Diode test

Display 128x64 px

Mains or battery power supply

FP-2B

AC / DC Voltage

AC / DC Current

Resistance

Diode test

Capacitance

Frequency

Transistor hFE test

IC-117, IC-118

AC / DC Voltage & CurrentResistanceCapacitanceDiode testContinuity testFrequencyTemperatureTrue RMSENAC CertificateCommunications kit

(optional for IC-118)

PD-163

AC / DC Voltage & Current

Resistance

CapacitanceFrequency

Diode test

Continuity test

MAX/MIN hold

Relative test

True RMS

PD-161

AC / DC Voltage & Current

Resistance

Capacitance

Frequency

Transistor test

Logic test

Diode test

Data/MAX/MIN hold

Continuity test

OS-782 POLISCOPE

Oscilloscope:

2 channels, 20 MHz, 100 MS/s, memory

5 automatic measurements

Vertical / horizontal cursorsTrigger TV / edge

Multimeter : AC / DC Voltage & Current, Diodes,

Resistance, Capacitance, Continuity

USB PC connection

Carrying case

MD-859

Desktop multimeter:

AC / DC Voltage & Current, Resistance,

Capacitance, Diode test, Frequency,

HOLD, Continuity, MAX/MIN, Relative.

Connections: GPIB (optional), RS-232C

PD-185

AC / DC Voltage & CurrentResistanceCapacitanceFrequencyContinuity testDiode testData / MAX / MIN memory±PEAK hold

Relative testPC connectionTrue RMS

PD-183

AC / DC Voltage

AC / DC Current

ResistanceFrequency

Duty cycle

Continuity test

Diode test

Logic test

Data hold

True RMS

PD-181

AC / DC Voltage AC / DC CurrentResistanceCapacitanceFrequencyTransistor testContinuity testDiode testLogic testMAX and data hold

MD-200B

Desktop multumeter:

AC / DC Voltage & Current, Resistance,

Continuity, Diodes, Capacitance, Freq.,

ADAPT measurement, 3 ¾ digits LCD

display with bargraph, backlighted.

PC connection

PC connection

Page 3: Catalogo de Equipos PROMAX

7/17/2019 Catalogo de Equipos PROMAX

http://slidepdf.com/reader/full/catalogo-de-equipos-promax 3/8

AE-966, AE-967

3 GHz Spectrum analysers

Frequency range: 9 kHz - 3 GHz

BW resolution: 3 Hz - 4 MHz

Tracking generator : Available for AE--967Battery operation as an option

Functions: AutoSet, Go/NoLo, jitter measurements,

OCBW, ACPR... RS-232, USB, PC software

Optional functions: GPIB interface, EMI filters

AM / FM demodulator

AE-766, AE-767

1 GHz Spectrum analysers

Frequency range: 150 kHz - 1 GHz

BW resolution: 3 kHz - 4 MHz

Functions: Tracking generator (AE-767), AM / FM

demodulation, RS-232, 10 markers

GR-205, GR-104

2 GHz / 1 GHz Synthesised RF generators

Frequencies: 150 kHz - 2 GHz / 10 MHz - 1 GHz

Output level range: -127 dBm to +7 dBm

Modulation: FM (GR-104) and AM/PM/Ext (GR-205)

Functions: GPIB (optional), RS-232, 9 memories

AC-725

Radiocommunications analyser, 2.5 GHz

Frequency Range: 20 MHz - 2.5 GHz

Functions: 3 GHz frequency counter, RF level

meter, AM/FM modulator meter, RS-232 interface

RADIOFREQUENCY·

MZ-805

R, L, C meter

Measurements: R, L, C and D & Q factors

Functions: Autoranging, zero compensation,

user-selectable measurement frequency,programmable, up to 9 set-ups, numeric keyboard

PC connection: Range/function control, limits

setting and results data-logging on the PC

Display: Dual 5-digit LEDs

MZ-505B

CP-534C

Hand-held component tester / Digital capacitance meter

Measurements: R, L, C and D / Q factors

Functions: Auto/manual ranging guard terminal,

zero compensation, selectable frequency, RS-232

interface, software

Measurement range: From 200 pF to 20.000 µF

Display: 3½ digit LCD

Functions: Zero compensation

COMPONENT TESTERS·

Basic range of high-end programmable instruments via RS-232 (availability of GPIB)

30 MHz arbitrary signal function synthesizer. 20 MHz resolution.

Programmable 15 MHz function generator. Multiple display.

Triple programmable DC power supply, 2x32V/2A and 6V/5A. Multiple display.

Programmable 4 ¾ dig. multimeter, true RMS. Multiple display.

Programmable 3 GHz universal frequency counter.

A RS-232 interface is included in all of these equipment. Optionally,

a GPIB interface (except GF-857) can be installed in factory at an affordableprice.

GF-857

GF-855

FA-851

MD-859

FD-853

FD-853

GF-855

MD-859

GF-857

FA-851

PR-875C

Intelligent universal programmer

Socket: 48-pin DIL/ZIF

Supported memories: PROM, EPROM, E2PROM,

Flash, serial PROM, NV RAM

Logic devices:: PAL, GAL, CEPAL, PEEL, FPLA,

EPLD, CEPAL, FPGA, CDLD

Other devices: µC single-chip, OTP/Flash

Ultra-fast programming speedUSB and parallel port PC connection

BM-130D

Ultra-violet radiation EPROMs eraser

Capacity: Allows the erasure of up to 40 devices

of 24 pins at a time

Wavelength: 2537 Angstrom

Exposure time: From 0 to 60 minutes

DEVICE PROGRAMMERS·

3Please browse our web site to get more information: www.promax.es

PC connection

PC connection

SUPPORTS MORE THAN

DEVICES

PROGRAMMABLE INSTRUMENTS (GPIB & RS-232)·

IC-002

Multi-range RF wattmeter

Power ranges: 5, 15, 50, 150, 500 W, full scaleFrequency range: 24 to 1000 MHzConnectors: "Quick Match", standard N femaleType (BNC, UHF, TNC male or female optional)

Page 4: Catalogo de Equipos PROMAX

7/17/2019 Catalogo de Equipos PROMAX

http://slidepdf.com/reader/full/catalogo-de-equipos-promax 4/8

TELECOMMUNICAT

PROLINK-4/4C Premium

PROLINK-3/3C Premium

TV & Satellite level meters

TV&SAT LEVEL METERS CABLE TV

Analogue measurements

QPSK

COFDM

QAM

Wi-Fi

DAB

Automatic measurements

Constellation

TS Input/Output

MPEG-2:

free channels

encrypted channels

Display

FM peak deviation

Impulse response

optional

optional

optional

-

-

-

-

optional

-

TFT / CRT TFT / CRT

-

-

PROLINK PROLINK

4/4C Premium 3/3C Premium

Unique functions:

Automatic exploration of the band and channel

identification, simply pressing one key

(EXPLORER function)Indicates network name over the spectrum

(AUTO ID function)

Spectrum graph controlled ny arrow keys, without

need of menus.

PRODIG-2

DVB-T Signal level meter

Tuning: 45 - 862 MHz by channels

Measurements: Level, channel power, C/N ratio,

V/A ratio, pass/fail indicator, test output

SKYHUNTER

Satellite field strength meter & satellite hunter

Satellite field strength meter

Functions: It helps installers to detect and identifysatellites in a 3 step procedure

Satellites: 16 maximum

Measurements: Power, CBER, MER

PROMAX-26DOCSIS / EURODOCSIS Cable modem analyser

Measurements & parameters: RF level, MER,BER, constellation, frequency, channel, channelplan, modulation, symbol rate, frequency,bandwidth, network attenuation, modulationDownstream frequency range: 50 to 857 MHzUpstream frequency range: 5 to 42 MHzModes: Registered / UnregisteredOther : Designed for both right & left-handed,soft-keys, datalogger, printer output

PROMAX-10 Premium

Cable TV analyser

Display: Spectrum and SPANAnalogue measurements: Level, C/N ratio,V/A ratio, CSO / CTB intermodulation

Digital measurements: Channel power, C/N ratio,BER, MER, constellation diagramFrequency range: From 5 to 862 MHzTuning mode: Frequency or channels(customizable channel plan)Sound: AM / FM demodulator, internal speaker,external speaker output

PROMAX-8 Premium

Cable TV analyser

Display: Spectrum and SPANAnalogue measurements: Level, C/N ratio,V/A ratio, CSO / CTB intermodulationDigital measurements: Channel power, C/N ratioFrequency range: From 5 to 862 MHzTuning mode: Frequency or channels(selectable channel plan)Sound: AM / FM demodulator, internal speaker,external speaker output

PROMAX-4, PROMAX-5, PROMAX-6

Cable TV signal level meters

Analogue measurements: Level, C/N, V/A

Digital (PROMAX-6): Power, C/N

Frequency range: 5 to 862 MHz

PROMAX-4 frequency range: 45 to 862 MHz

PROLINK-1C

Basic Cable TV analyser

Functions: Analogue measurements, acoustic toneFrequency range: From 46 to 856 MHzReturn path (optional): From 5 to 45 MHzIndication: 16 digit alphanumeric LCD display

RP-100, RP-100Q

Return Path multi-carrier generator

Carriers: 2 (RP-100) or 4 (RP-100Q)

Frequency range: From 5 to 100 MHz

Level: From 30 to 50 dB (resolution: 1 dB)

RP-200

Multicarrier generator

Carriers: 2

Frequency range: From 5 to 862 MHz

Level: From 30 to 50 dB (resolution: 1 dB)

4Please browse our web site to get more information: www.promax.es

RP-250

Multi carrier generator

Frequency & level agile carriers: 8 simultaneous(3 x VHF/UHF, 3 x SAT, 1 x sub-band, 1 x ISM)Frequency range: From 5 to 2500 MHzResolution: 10 kHzLevel: From 90 to 110 dBµVETHERNET: Remote control through Internet or LAN

conexión a PC

PC connection

PC connection

PC connection

PC connection

TV EXPLORER

PC connection

Measurements and functions:

Signal level

Video / Audio ratio

Carrier / Noise ratio

Digital channel power

MER, BER, VBER and CBER

Noise margin

Automatic measurements

(Datalogger)

Automatic report generation

(optional software)

Spectrum analyser

Attenuation test

SAT IF test

Syncronism fault indicator

(saturation detection)

DiSEqCTM and LNB supply

Firmware updates

MPEG-2 decoder

Ultra small size: 230 x 261 mm, 2 Kg.Display: 5” high brightness Colour TFT

Battery life: more than 4 hours

Page 5: Catalogo de Equipos PROMAX

7/17/2019 Catalogo de Equipos PROMAX

http://slidepdf.com/reader/full/catalogo-de-equipos-promax 5/8

ONS TEST EQUIPMENT

PROLITE-60Field Optical spectrum analyser

Wavelength: From 1250 nm to 1650 nm

Span: From 10 nm to 400 nm

Optical resolution: 0.150 nm

Dynamic range: From -60 dBm to 10 dBm

Monitor : 6.4” Colour TFT

Special measurement functions

Firmware upgrades via Internet

PROLITE-50

Micro OTDR

Dynamic range: 24 dB

Wavelength: 1310 nm and 1550 nm

Functions: 100 memories, interchangeable fibre

optic connectors, PC software, RS-232 and USB

interfaces

PROLITE-23

Optical power meter

Wavelength: 850 / 980 / 1310 / 1480 / 1550 nmFunctions: W / µW / dBm / dB (REF),auto-zeroing, data hold...Measurement range: -60 to 17 dBmData storage: 3200 recordsPC connection: RS-232 port

PROLITE-30, PROLITE-11

Optical fibre identifier & Visual fault locator

PROLITE-30: It detects and identifies signal

direction and modulation (270 Hz, 1 kHz, 2 kHz)

PROLITE-11: Laser source 650 nm, 2 mW.

Universal connector, continuous wave (CW)

or pulsed laser

OPTICAL FIBRE·

PROPOWER-5PLC spectrum analyser

Frequency range: From 1 MHz to 50 MHz

Power : From -90 dBm to 10 dBm

Resolution: 200 kHz

Operating modes: Spectrum / TILT

Datalogger for PLC channels

Hand-held

PROPOWER-1

PLC noise generator

Frequency range: From 1 MHz to 50 MHz

Power : 5 dBm

Hand-held

POWER LINE (PLC)·

PROFI-70

Wireless analyser

Features: Detects all of the 14 Wi-Fi channels

(IEEE 802.11b, 802,11g standards), wrong packets

ratio, channel power, supports WEP encryption

ISSD network identification

Display: LCD screen

Portable

Low cost

Wi-Fi ANALYSER·

Power Line Communications

5Please browse our web site to get more information: www.promax.es

ACCESSORIES

RP-080

Satellite & terrestrial simulator, 4 carriers

Frequencies: 85, 750, 1000

and 2150 MHz

Level: From 75 to 105 dBµV

(selectable and independent for

each carrier)

Power supply: From LNB or an

external DC supply

RP-050

IF & Satellite simulator, 3 carriers

Frequencies: 1050, 1575, 2100 MHz

Level: 90 dBµV (LOW mode),

105 dBµV (HIGH mode)

Power supply: From LNB or an

external DC supply

NG-281, NG-282

Noise generators

NG-281: Up to 1 GHz (70 dBµV)

NG-282: Up to 2 GHz (50 dBµV)

Power supply: Batteries or

external power adaptor

CV-245, CV-589

Wi-Fi band converters

Function: Convert 2.4 GHz signals (CV-245) or

5.8 GHz signals (CV-589) to SAT band.

Power supply: From LNB

Applications: Wireless link antenna alignment,

measurements on WLAN or ISM network signals

MS-250

Satellite detector

Frequency range:

950 to 2050 MHz

Detection:

-30 to +5 dBm

Indication: acoustic

Reading: analogue

Master aerial

AMC/1

Function: Connected

to any Field Strength

meter is able to find

the intensity of the

electric field in any

location.

Wavelength: 1310 nm and/or1550 nm

One output: multiplexed optical output

Level: -5 dBm

Modulation: 270 Hz and 2 kHz

PROLITE-90

Dual wavelength LASER light source

PC connection PC connection

PC connection

PC connection

PC connection

Page 6: Catalogo de Equipos PROMAX

7/17/2019 Catalogo de Equipos PROMAX

http://slidepdf.com/reader/full/catalogo-de-equipos-promax 6/8

6Please browse our web site to get more information: www.promax.es

TC-475

Mains & PLC wiring tracer

Composed of transmitter & receiver modules

Voltage range: From 100 to 250 V, 30-70 Hz

Maximum depth: 40 cm (cable tracing)or 10 cm (protection devices)

Transmitter : Mains plug format

TC-470

Wiring tracer with battery operated transmitter

Composed of transmitter & receiver modules

Sensitivity: Adjustable

Transmitter : Tone generator

Receiver : Amplified probe

TC-471

LAN & telephony cable tester

Wiring types: T568A/B, USOC, 10BASE-T,

BNC/10BASE-2, TOKEN, RING &

TP-PMD and coaxialLCD display: Network layout identification

Memories: Up to 4 customizable wiring types

IC-014, IC-051

Universal voice & data networks analyser (CAT 6 & 7)

Category: 6/ISO E upgradeable to Cat 7 / ISO FMax frequency: 350 MHz (upgradeable to 750 MHz)IC-051: Cat. 7/ISO E; Max frequency 750 MHzOptical fibre kit: OptionalReflectometer : IncludedUniversal connection system

IC-013

Voice & data networks analyser (CAT 6)

Category: 5, 5e and 6 ISO E

Maximum frequency: 300 MHz

Optical fibre kit: Optional

Reflectometer : Included

IC-032

LAN & Telephony tester with wire length indication

Cable types: STP / UTP, Cat-5E, Cat-5,Cat-4, Cat-3 and coaxialMax length: 914 m (depending on impedance)Included accessories: One remote terminator,two jumper cables, CATV terminator,RJ-45 to F Adaptor, carrying case

IC-124

IDSN and ADSL 2 / 2+ telephony tester

Tepephony tester for ADSL2/2+, ADSL, ISDN

and POTS

Measurements: Emulation and modem substitu-

tion. IP video tests / curl. ISDN analyser / simula-

tor. POTS analyser..

PC connection: Data transfer & protocol analysis

IC-023

ISDN, analogues and POTS telephony tester

Measurements: ISDN and analogues (POTS)

PC connection: Data transfer & protocol analysis

STRUCTURED CABLING & TELEPHONY NETWORKS

MR-275

Dual Digital tachometer

LASER tachometer : From 5 to 99,999 RPM

Contact tachometer : From 0.5 to 19,999 RPM

Optical detecting distance: From 5 to 100 cm

Memories: Last, maximum and minimum values

PE-005

Audio impedance tester

Measurement range: 20 Ω, 200 Ω, 2000 Ω

Test frequency: 1 kHz

Application: It allows to estimate the necessary

power in an installation for the suitable election

of the amplifier.

IL-185

Lux meter 200,000 Lux

Range: From 0.01 to 200,000 Lux

Resolution: 0.01 Lux max

Generals: High diffusion accuracy (ϕ < 2%),

high ϕ accuracy compensation,backlight LCD display, analogue output

SC-002

Sound level meter

Dynamic range: 20 to 130 dBA (RMS)

Functions: Fast (LAF), Slow (LAS) and maximum

ELECTRIC EQUIPMENT

ELECTROMAGNETISM

MG-626

Electromagnetic field monitor

Measurement range: From 5 Hz to 3 GHz (*)

Full scale sensitivity: 20 - 50 - 100 V/m

Measurement level range: 0.5 to 100 V/m

Interchangeable probes to measure electromag-

netic field on Mobile Phone and Electrical power distribution network

Functions: Real time data acquisition via PC or

PDA or in stand alone modes to process data at a

later stage. Availability of a fix set up with wireless

connection.(*) Depending on the probes

AR-225

Phase sequence indicator

3 instruments in 1: indication of open phase,

phase sequence, motor rotation

Input voltage: 100 V AC at 600 V AC max.Frequency range: From 45 to 70 Hz

MP-003

Audio impedance meter

Measurement range: 200 Ω, 2 kΩ, 20 kΩ

Test frequency: 1 kHz

Power : 0 - 2000 W

Application: enables knowing the resistancein DC and the minimum power required by

an amplifier to attack an impedance

PC connection

PC connection

Page 7: Catalogo de Equipos PROMAX

7/17/2019 Catalogo de Equipos PROMAX

http://slidepdf.com/reader/full/catalogo-de-equipos-promax 7/8

CT-098, CT-193

AC and AC/DC current clamps

AC current: 200, 700 and 20 A (CT-098)

DC current (CT-193): 200 A and 700 A

DC and AC voltage: 600 V rangeImpedance: Up to 200 kΩ

Frequency: Autorange to 20 kHz

CT-195

AC/DC wattmeter clamp

AC current: Up to 700 A

DC current: 430 A, 700 A

DC / AC voltage: Up to 600 V

Impedance: Up to 43 MΩ

Frequency: 430 Hz / 4.3 kHz

Temperature: Up to 850 ºC

CT-237Leakage current clamp

AC current: Up to 60 A

AC voltage: Up to 400 V

Resistance: Up to 400 Ω

PT-125

Three-phase wattmeter clamp (2000 kW)

Power measurement: Three-phase current,

active, reactive, cos ϕ

Three-phase margin: 2000 kW

Single-phase margin: 1200 kW

Voltage measurement: 600 V AC, 800 V DCCurrent measurement: 2000 A AC+DC

PE-335

Digital earth resistance tester

Earth resistance measurements by means of

current injection: 820 Hz, 2 mA

Earth voltage: 0 ~ 200 V AC, 50 / 60 Hz

Functions: Timer for test function, earth voltage

measurement.

PE-425

Electrical network analyzer (LOOP, PSC & EARTH TESTER)

Loops / Earth / Wires: 0.03 - 2000 Ω

Prospective Short Circuit: Up to 0.6 kA

Functions: Earth resistance, voltmeter,

display L-N and L-E voltages, display earth

impedance, PSC Line, Neutral and Earth.

IC-020

Professional loop resistance meter

Measurements: Short circuit current, loop

impedance, reaction time & current protections

test, phase sequence

IrDA interface: Possibility to transmit, print and

format stored data according to predefined

protocols, firmware upgrades

Display: Backlighted LCD graphic display

IC-007

Three-phase network analyser

Functions: Power, harmonics, flicker,

disturbances, check meter, fast check

Basic parameters: Voltage, current, active andreactive power, energy, voltage & current harmonics,

flicker

IC-016

Low voltage installation tester

Measurements: Voltage, frequency, differential

switch test, earth resistance, isolation,

network impedance, low resistance, phase rotation

IC-028Three phase network tester

Measurements (summary): Continuity, isolation,

active / reactive / aparent power, active & reactive

energy, phase sequence, voltage / current TRMS,

disturbances...

IC-029

Contactless voltage detector

It allows to safely detect mains voltage

presence (up to 230 V)

Find wire interruptions, check fuses,identify phases

7Please browse our web site to get more information: www.promax.es

ELECTRIC EQUIPMENT·

PE-365

Digital RCD tester

Function: Off-time measurement for Protecting

Residual-Differential Current devices

Test current: From 3 mA to 500 mA

Phase Start Selection: 0° and 180° referenced

to Earth.

PE-457

Automatic analog / digital isolation meter

Isolation measurement: Up to 4000 MΩ

Test current: 250, 500 and 1000 V

AC voltage measurement: 600 V AC

PE-455

Insulation tester

Insulation Resistance: 20 MΩ - 2000 MΩ

Test current: 250 V, 500 V, 1000 V

Output current: 1 mA

Page 8: Catalogo de Equipos PROMAX

7/17/2019 Catalogo de Equipos PROMAX

http://slidepdf.com/reader/full/catalogo-de-equipos-promax 8/8

Please browse our web site to get more information: www.promax.es

PROMAX ELECTRONICA, S. A.

Francesc Moragas, 71 * 08907 HOSPITALET * SPAIN

Tel: (+34) 93 260 20 02 * Fax: (+34) 93 338 11 26 * e-mail: [email protected] * http://www.promax.es

GV-698+

Medium range TV Generator

Pattern charts: 23

Outputs: RF, YPbPr, RGB, S-VHS, SCART,

Synchronisms, Composite video

Logotypes: one or two, independants and

positionables

TV & MONITOR PATTERN GENERATORS

VECTORSCOPE

IC-030

Vectorscope

Function: It shows video signal colour compo-

nents in the form of vectors

Display: TRC 150 mm with scale

DP & DG measurements: Using modulated stair

case pattern

WAVEFORM MONITOR

IC-031

Waveform monitor

Function: Measurement of composite video ampli-tude, timing and frequency responseSystems: B, C, D, G, H, I, KFrequency response: FLAT, DIF GAIN, LUMCHROMA, DIF’D STEP

S P E C I F I C A T I O N S A R E S U B J E C T T O C H A N G E W I T H O U T N O T I C E

0 4 / 0 7

0 I P 1 2 3 3

For more information please visit www.promax.es or contact our distributor:

MO-170

DVB-T & DVB-H modulator for 19” rack mount

Master / slave operating modesTS MPEG-2 input: 2xDVB-ASI, 1xDVB-SPI

Outputs: IF (35-37 MHz), RF (45-875 MHz)Guard intervals: 1/4, 1/8, 1/16, 1/32Code rates: 1/2, 2/3, 3/4, 5/6, 7/8Constellations: QPSK, 16QAM, 64QAMChannel bandwidth: 6, 7, 8 MHz (selectable)OP-170-E option: Noise generator for C/N testing.Fixed and mobile channels simulator in SFN/MFNnetworks.OP-170-H option: DVB-H dignal generator.OP-170-P option: +10 dBm power output.

IC-065

TS multiplexer for 3 video/audio channels

Encodes 3 V/A channels into a single MPEG-2 TS

Video: PAL, SECAM, NTSC, up to 20 Mbps

Input: 3xBNC (video), 3xDIN 45326 (audio)

TG-140

Transport Stream recorder, processor & player

Application: MPEG-2 Transport Stream recorder and player, single-service or multiple servicesInputs: ASI TS 150 MBpsOutputs: ASI TS, SPI Parallel, 90 MbpsStorage capacity: Up to 160 GB (15 hours)PC connection: USB and Ethernet

PC connection

GV-998

Analogue and digital TV pattern generator

Pattern charts: 37

Outputs: RF, YPbPr, TS MPEG-2, RGB, S-VHS,

SCART, Sync, Blackburst, Composite video

MPEG-2 TS outputs: Parallel (SPI) and serial (ASI)

Logotypes: 2 independent and positionable logos;

analogical & MPEG

Modulator : Vestigial side band

GV-898+, GV-798+

TV pattern generators

Pattern charts: 37

Outputs: RF, YPbPr, RGB, S-VHS, SCART,

Sync, Blackburst, Composite video

GV-798+ modulator : Double sideband DSB

GV-898+ modulator : Vestigial sideband VSB

Logotypes: 2 independent and positionable logos

GV-241

Test generator for monitors

Pattern charts: 8

Outputs: 2 x D9, D15, RGB, sync

(composite, horizontal, vertical), video without sync.

Maximum resolution: 1600 x 1200 @ ~ 90 HzOptional: Custom resolution

GV-198Economy range TV pattern generator

Pattern charts: 9

Outputs: RF, RGB, S-VHS, Sync, SCART, Composite video

Modulator : Double sideband

PC connection

PC connection