20
Solar systems (1-2) Condensing boilers (3-8) Wall - hanging boilers (9-12) Cast - iron standing boilers (15-16) Domestic hot water tanks (17) Instantaneous water heaters (13-14)

Catalog Produse Termet (en)_tq0u1y (1)

Embed Size (px)

Citation preview

Page 1: Catalog Produse Termet (en)_tq0u1y (1)

Solar systems (1-2)

Condensing boilers (3-8)

Wall - hanging boilers (9-12)

Cast - iron standing boilers (15-16)

Domestic hot water tanks (17)

Instantaneous water heaters (13-14)

Page 2: Catalog Produse Termet (en)_tq0u1y (1)

Solar Systems

www.termet.com.pl

Condensing boiler connected with solar systems

EconoMax solar pab 35.35 bt2

Technical features:

- Condensing boiler

- Power 7-34,6 kW

- Efficiency 108 %

- Energetic class * * * *

- PREMIX burner with pre-admixing system

- Modulating fan and modulating pump

- Weater regulation

- Open- therm function accessible

- Flexible tubing as standard equipment

- Floor heating circuit built in

- Mixing valve system built in

- Modulating pump for floor circuit built in

- regulation directly from boiler control board

- D.H.W system0- 46 l /min by Dt= 30 C

- 200 liters stratified tank made of stainless stell built in

- 40 kW plate heat exchanger and pump to supply stratified

tank built in

- Drain back solar system

- Modulating pump to solar liquid built in

Central heating circuit

Domestic hot water circuit

Nominal heating loud

Heating power (80 / 60 C)

Heating power (50 / 30 C)

Efficiency by temp. in/out (50 / 30 C)

Spr Efficiency by temp. in/out (80 / 60 C)

Gas consumption by power min.-max.:

- NG: 2E-G20-20 mbar

- LPG propane- butane

Maximum water pressure

Maximum working temperature

Minimum working temperature

Working environment temperature

Nominal heat power

Working pressure

Capacity of plate heat exchanger

Water flow

Hydraulic parameters

Electrical data

Gas combustion parameters

Assembly dimensions

Capacity of main heat exchanger

Capacity of expansion vessel

Pressure in expansion vessel

Electrical data

Power intake

Pump electric al power

IP protection level

Energetic efficiency

Class of NOx

Chimney connection

Dimensions

Mass of boiler

TECHNICAL DATA

0 0

0 0

0 0

0 0

kW

kW

kW

%

%

Nm /h

kg/h

MPa(bar)

C

C

C

kW

bar

dm

dm /min

0

0

0

3

3

3

7-34,6

6,8-35,4

7,5-38,9

108

98,2

0,70-3,47

0,55-2,70

0,3 (3)

85

25

1-60

7-34,6

8

200

46

dm

dm

bar

V/Hz

W

W

IP

92/42/EEc

EN 483

mm

mm

kg

3

3

3,7

18

1

230/50

400

93

44

****

5 (24 mg/kWh)

80/ 125, 60/ 100

2x 80x 80

1770x600x600

185

Ø Ø Ø Ø

Ø Ø

BOILER SCHEMA

1. Floor heating circuit

2. Primary heating circuit

3. Tank for absorbing liquid

4. Plate heat exchanger

5. D.H.W stratified tank

6. D.H.W compensation vessel

7. C.H. compensation vessel

1

Page 3: Catalog Produse Termet (en)_tq0u1y (1)

Solar Systems

www.termet.com.pl

Solar collector

Solar DB

Total surface of collector

Absorbing surface

High

Wide

Thickness

Mass

Capacity

Diametr of copper tubes

inside of collectors

Assembly

Absorption

Emission

Glass thickness

Maximum pressure in circuit

Maximum quantity of collectors

Minimum grade of collector

Minimum efficiency

TECHNICAL DATA

m

m

mm

mm

mm

kg

dm

mm

-

%

%

mm

bar

unit

degree

kWh/m

2 2,24

2,02

1930

1160

90

43

1,1

10

horizontal

95

5

4

10

4

15

524

Accessories:

Outside controller with

OPEN THERM ® regulator’s

function

Outside temperature

sensor

Valve set

Concentric solar tube

Holder for montage

Montage set for sloped

roof

Connector

Montage set for flat

roof

Liquid for solar system

- capacity

2

2

3

2

Page 4: Catalog Produse Termet (en)_tq0u1y (1)

Condensing Boilers

www.termet.com.pl

3

Two - function condensing boiler

EconoMax pab 35.35 bt2

Technical features:

- Condensing boiler

- Power 7 - 35 kW

- Efficiency 108 %

- Energetic class * * * *

- PREMIX burner with pre-admixing system

- Modulating fan and modulating pump

- Weater regulation

- Open- therm function accessible

- Flexible tubing as standard equipment

- Floor heating circuit built in

- Mixing valve system built in

- Modulating pump for floor circuit built in

- regulation directly from boiler control board

- D.H.W system0- 25 l /min by Dt= 30 C

- 150 liters stratified tank made of stainless stell built in

Output power in central heating circuit

Output power in domestic hot water circuit

Boiler efficiency

Minimum working temperature .

Maximum working temperature

Expansion tank capacity

Expansion tank pressure

Maximum central heating water pressure

Maximum. water pressure in d.h.w. circuit

Flow rate by Dt = 30 C

Protection level

Height

Width

Depth

Weight

TECHNICAL DATA

kW

kW

%

C

C

l

bar

bar

bar

l/min

IP

mm

mm

mm

kg

7-35

35

108

45

85

18

1

3

8

25

44

1517

600

600

204

0

0

0

DesignEcology

Technology

Modernity

Page 5: Catalog Produse Termet (en)_tq0u1y (1)

Condensing Boilers

www.termet.com.pl

4

Output power in central heating circuit

Output power in domestic hot water circuit

Boiler efficiency

Minimum working temperature .

Maximum working temperature

Expansion tank capacity

Expansion tank pressure

Maximum central heating water pressure

Maximum. water pressure in d.h.w. circuit

Flow rate by Dt = 30 C

Protection level

Height

Width

Depth

Weight

TECHNICAL DATA

kW

kW

%

C

C

l

bar

bar

bar

l/min

IP

mm

mm

mm

kg

7 - 24

-

107

25

85

10

1

3

-

-

44

820

457

240

50

0

0

0

7 - 35

-

108

25

85

10

1

3

-

-

44

820

457

240

50

7 - 24

7 - 35

107

25

85

10

1

3

8

16,8

44

820

457

240

53

7 - 35

7 - 35

108

25

85

10

1

3

8

17,2

44

820

457

240

53

TermoCondens plus One - function Two - function

Type MB.BT 24.35 MB.BT 35.35 PMB.BT 24.35 PMB.BT 35.35

Technical features:

- Condensing boiler

- Efficiency 108 %

- Energetic class * * * *

- PREMIX burner with pre-admixing system

- Modulating fan and modulating pump

- Weater regulation

- Open- therm function accessible

- Floor heating circuit built in

- Mixing valve system built in

- Modulating pump for floor circuit built in

- regulation directly from boiler control board

- D.H.W system0- 17,2 l /min by Dt= 30 C (pmb.bt 35.35)0- 16,8 l /min by Dt= 30 C (pmb.bt 24.35)

- Cooperation with domestic hot water tank by

three-way valve (one - function condensing boilers)

Condensing boilers

Termo plusCondens

One-function:

MB.BT 24.35 7-24 kW - central heating water

MB.BT 35.35 7-35 kW - central heating water

Two - function:

PMB.BT 24.35

PMB.BT 35.35

7-24 kW - central heating water

7-35 kW - domestic hot water

7-35 kW - central heating water

7-35 kW - domestic hot water

Accessories:

Outside temperature

sensor

NTC sensor to hot

water tank

Three-way valve

Outside controller

with OPEN THERM ®

regulator’s function

Page 6: Catalog Produse Termet (en)_tq0u1y (1)

www.termet.com.pl

5

Condensing Boilers

Technical features:

- Condensing boiler

- Efficiency 108 %

- Energetic class * * * *

- PREMIX burner with pre-admixing system

- Modulating fan and modulating pump

- Weater regulation

- Open- therm function accessible

- Floor heating circuit built in

- D.H.W system0- 17,2 l /min by Dt= 30 C (pmb.bt 35.35)0- 16,8 l /min by Dt= 30 C (pmb.bt 24.35)

- Cooperation with domestic hot water tank by

three-way valve (one - function condensing boilers)

Condensing boilers

TermoCondens

One-function:

MB 24.35 7-24 kW - central heating water

MB 35.35 7-35 kW - central heating water

Two - function:

PMB 24.35

PMB 35.35

7-24 kW - central heating water

7-35 kW - domestic hot water

7-35 kW - central heating water

7-35 kW - domestic hot water

Accessories:

Outside temperature

sensor NTC sensor to hot

water tank

Three-way valve

Output power in central heating circuit

Output power in domestic hot water circuit

Boiler efficiency

Minimum working temperature .

Maximum working temperature

Expansion tank capacity

Expansion tank pressure

Maximum central heating water pressure

Maximum. water pressure in d.h.w. circuit

Flow rate by Dt = 30 C

Protection level

Height

Width

Depth

Weight

TECHNICAL DATA

kW

kW

%

C

C

l

bar

bar

bar

l/min

IP

mm

mm

mm

kg

7 - 24

-

107

25

85

10

1

3

-

-

44

760

400

300

52

0

0

0

7 - 35

-

108

25

85

10

1

3

-

-

44

760

400

300

55

7 - 24

7 - 35

107

25

85

10

1

3

8

16,8

44

760

400

300

55

7 - 35

7 - 35

108

25

85

10

1

3

8

17,2

44

760

400

300

59

TermoCondens One - function Two - function

Type MB 24.35 MB 35.35 PMB 24.35 PMB 35.35

Outside controller

with OPEN THERM ®

regulator’s function

Page 7: Catalog Produse Termet (en)_tq0u1y (1)

www.termet.com.pl

6

Condensing Boilers

Condensing boiler

MasterHeat M55

Output power in central heating circuit

Output power in domestic hot water circuit

Boiler efficiency

Minimum working temperature .

Maximum working temperature

Expansion tank capacity

Expansion tank pressure

Maximum central heating water pressure

Maximum. water pressure

Flow rate by Dt = 30 C

Protection level

Height

Width

Depth

Weight

TECHNICAL DATA

kW

kW

%

C

C

l

bar

bar

bar

l/min

IP

mm

mm

mm

kg

15 - 55

-

108

25

85

2

1

3

-

-

44

820

457

240

55

0

0

0

termet termet

Technical features:

- Condensing boiler

- Power 15 - 55 kW

- Efficiency 108 %

- Energetic class * * * *

- PREMIX burner with pre-admixing system

- Modulating fan

- Weater regulation

- Open- therm function accessible

- Application

- One - function boiler - only heating

- Heating and cooperation with domestic hot water tanks

through three way valve

- Cascade systems (max 8 units - 440 kW power)

Accessories:

Outside temperature

sensor

NTC sensor to hot

water tank

Three-way

valve

Outside controller

with OPEN THERM ®

regulator’s function

Menager cascade

controller

Cascade schema:

1. Hydraulic header

2. Inlet collector

3. Outlet collector

4. Menager cascade controller

Page 8: Catalog Produse Termet (en)_tq0u1y (1)

www.termet.com.pl

Condensing Boilers

7

Technical features:

- Condensing boiler

- Efficiency 107,7 %

- Energetic class * * * *

- Steinless steel PREMIX burner

- Steinless stell heat exchanger

- Modulating fan

- Control board with LCD display and full auto-

diagnostic system

- Weather regulation built - in

- Low energetic consumption pump with built-in air vent

- Open- therm function accessible

- D.H.W system

- Steinless steel plate heat exchanger (refer to two-

function models)

- Three way electic drive valve (refer to two-function

models)

- Domestic hot water production: 012 l /min by Dt= 30 C (Windsor -25)014 l /min by Dt= 30 C (Windsor -30)

- Cooperation with domestic hot water tank by

three-way valve (refer to one - function models)

Condensing boilers

Windsor

One-function:

25 7-24 kW - central heating water

30 7-29 kW - central heating water

Two - function:

25

30

7-24 kW - central heating water

7-24 kW - domestic hot water

7-29 kW - central heating water

7-29 kW - domestic hot water

Output power in central heating circuit

Output power in domestic hot water circuit

Boiler efficiency

Modulating range

Maximum working temperature

Expansion tank capacity

Expansion tank pressure

Maximum central heating water pressure

Maximum. water pressure in d.h.w. circuit

Flow rate by Dt = 30 C

Protection level

Chimney connection

Height

Width

Depth

TECHNICAL DATA

kW

kW

%

%

C

l

bar

bar

bar

l/min

IP

mm

mm

mm

mm

7 - 24

-

107,7

20-100

95

8

0,8

3

-

-

44

705

400

348

0

0

7 - 29

-

107,7

20-100

95

8

0,8

3

-

-

44

705

400

378

7 - 24

7 - 24

107,7

20-100

95

8

0,8

3

6

11,9

44

705

400

348

7 - 29

7 - 29

107,7

20-100

95

8

0,8

3

6

14

44

705

400

378

Windsor One - function Two - function

Type 25 30 25 30

Ø60/100 or Ø80/125 or 2x Ø80

Accessories:

Three-way

valve

Outside temperature

sensor

NTC sensor to hot

water tank

Wireless temperature

regulator termet

termet

Page 9: Catalog Produse Termet (en)_tq0u1y (1)

Condensing Boilers

www.termet.com.pl

8

Condensing boiler

Windsor

Technical features:

- Condensing boiler

- Efficiency 109 %

- Energetic class * * * *

- Steinless stell heat exchanger

- Modulating fan

- Control board with LCD display and full

auto-diagnostic system

- Weather regulation built - in

- Primary pump built - in

- Open- therm function accessible

- Application

- One - function boiler - only heating

- Heating and cooperation with domestic hot water tanks

through three way valve

- Cascade systems (max 6 - units)

Accessories:

Outside temperature

sensor

NTC sensor

to hot water

tank

Three-way

valve

Menager cascade

controller

One-function:

50 8-47 kW - central heating water

110 34-108 kW - central heating water

Output power in central heating circuit

Boiler efficiency

Modulating range

Maximum working temperature

Maximum central heating water pressure

Protection level

Power consumption

Chimney connection

Height

Width

Depth

TECHNICAL DATA

kW

%

%

C

bar

IP

W

mm

mm

mm

mm

8-47

107,7

20-100

80

3

44

200

705

400

420

0

Windsor 11050

34-108

109

30-100

80

3

44

330

705

420

440

Wireless temperature

regulator termet

termet

Cascade schema:

1. Hydraulic header

2. Inlet collector

3. Outlet collector

4. Menager cascade controller

Ø60/100 or Ø80/125

or 2x Ø80

Page 10: Catalog Produse Termet (en)_tq0u1y (1)

Wall-hanging Boilers

www.termet.com.pl

9

Two-function boilers

Technical features:

MiniMax dynamic GCO-DP-13-10

- Opened combustion chamber

- Power- 7-13 kW and 7-24 kW;

MiniMax dynamic turbo GCO-DP-21-03

- Closed combustion chamber

- power- 6-21 kW, 7-24 kW and 8-29 kW

- Very small sizes of boiler - 700 mm, 360 mm, 300 mm

- Multifunction control panel with digital display

- Full auto-diagnostic system through error codes

- Copper Main heat exchanger installed on fast connections

- Electronic ignition with ionization flame’s control

- Soft ignition function

- Hydroblock instalen on quick connections

- Secondary plate heat exchanger made of steinless stell

- Weather regulation function accesible

- Complete system of preventions

- Adjustment to every kind of gas

Output power in central heating circuit

Output power in domestic hot water circuit

Boiler efficiency

Maximum working temperature

Regulated temperature

Expansion tank capacity

Expansion tank pressure

Maximum central heating water pressure

Maximum. water pressure in d.h.w. circuit

Flow rate by Dt = 30 C

Rang of temperature regulation

Protection level

Chimney connection

Height

Width

Depth

Weight

TECHNICAL DATA

kW

kW

%

C

C

l

bar

bar

bar

l/min

C

IP

mm

mm

mm

kg

7 - 13

7 - 24

89,7

95

40-85

6

0,8

3

0,1-6

11,4

30-60

44

700

360

300

28

0

0

0

7 - 24

7 - 24

91

95

40-85

6

0,8

3

0,1-6

11,4

30-60

44

700

360

300

28

6 - 21

6 - 21

92

95

40-85

6

0,8

3

0.1-6

10

30-60

44

700

360

300

33

7 - 24

7 - 24

92

95

40-85

6

0,8

3

0,1-6

11,4

30-60

44

700

360

300

33

MiniMax Dynamic gco-dp-13-10 Dynamic turbo gco-dp-21-03

Type 13/24 24/24 6/21 24/24

36 mm00

3

0 mm

70

m0

m

0

Ø80/125 or Ø60/100 or 2x Ø80

Accessories:

Outside temperature

sensor

Wireless temperature

regulator

termet

termet

DesignEcology

TechnologyModernity

Ø130 Ø130

Page 11: Catalog Produse Termet (en)_tq0u1y (1)

Wall-hanging Boilers

www.termet.com.pl

10

Two-function boilers

Technical features:

MiniTerm GCO-DP-21-23

- Opened combustion chamber

- Power- 7-24 kW

MiniTerm turbo GCO-DP-21-13

- Closed combustion chamber

- power- 7-24 kW

- Very small sizes of boiler - 700 mm, 360 mm, 300 mm

- Multifunction control panel with digital display

- Full auto-diagnostic system through error codes

- Copper Main heat exchanger installed on fast connections

- Electronic ignition with ionization flame’s control

- Soft ignition function

- Hydroblock instalen on quick connections

- Bi-thermal heat exchanger made of copper

- Weather regulation function accesible

- Complete system of preventions

- Adjustment to every kind of gas

360 mm300 mm

700 m

m

Output power in central heating circuit

Output power in domestic hot water circuit

Boiler efficiency

Maximum working temperature

Regulated temperature

Expansion tank capacity

Expansion tank pressure

Maximum central heating water pressure

Maximum. water pressure in d.h.w. circuit

Flow rate by Dt = 30 C

Rang of temperature regulation

Protection level

Chimney connection

Height

Width

Depth

Weight

TECHNICAL DATA

kW

kW

%

C

C

l

bar

bar

bar

l/min

C

IP

mm

mm

mm

mm

kg

0

0

0

7 - 24

7 - 24

92

95

40-85

6

0,8

3

0,1-6

11,4

30-60

44

700

360

300

28

7 - 24

7 - 24

93

95

40-85

6

0,8

3

0,1-6

11,4

30-60

44

700

360

300

33

MiniTerm

Type 24/2424/24

0

Ø80/125 or

Ø60/100 or 2x Ø80

MiniTerm MiniTerm turbo

termet

termet

termet

termet

Wireless temperature

regulator

Twenty - four hour

temperature regulator

Weekly temperature

regulator

termet 1310

termet 2510

termet 3000 TX

Accessories:

Ø 130

Page 12: Catalog Produse Termet (en)_tq0u1y (1)

Wall-hanging Boilers

www.termet.com.pl

11

Two-function boilers

MaxiTermMaxiTerm

Technical features:

MaxiTerm GCO-DP-29-26

- Opened combustion chamber

- Power- 10-29 kW and 12-33 kW

MaxiTerm turbo GCO-DP-29-36

- Closed combustion chamber

- Power- 10-29 kW and 12-33 kW

- Silent work

- Multifunction control panel with digital display

- Full auto-diagnostic system through error codes

- Copper Main heat exchanger

- Electronic ignition with ionization flame’s control

- Soft ignition function

- Bi-thermal heat exchanger made of copper

- Domestic hot water production: 013,8 l /min by Dt= 30 C (10-29 kW)0 15,8 l /min by Dt= 30 C (12-33 kW)

- Weather regulation function accesible

- Complete system of preventions

- Adjustment to every kind of gas

Output power in central heating circuit

Output power in domestic hot water circuit

Boiler efficiency

Maximum water presure

Maximum working temperature

Central heating temperature

D.H.W. circuit temperature

Expansion tank capacity

Maximum central heating water pressure

Flow rate by Dt = 30 C

Protection level

Chimney connection

Height

Width

Depth

Weight

TECHNICAL DATA

kW

kW

%

bar

C

C

C

l

bar

l/min

IP

mm

mm

mm

kg

mm

10-29

10-29

92

0,3

95

40-85

30-60

6

3

13,8

44

130

700

460

300

30

Ø

0

0

0

0

termet

termet

termet

termet

Wireless temperature

regulator

Twenty - four hour

temperature regulator

Weekly temperature

regulator

termet 1310

termet 2510

termet 3000 TX

Accessories:

MaxiTermMaxiTerm

turbotype turbo

12-33

12-33

92

0,3

95

40-85

30-60

6

3

15,8

44

130

700

460

300

30

Ø

10-29

10-29

92

0,3

95

40-85

30-60

6

3

13,8

44

700

460

300

35

12-33

12-33

92

0,3

95

40-85

30-60

6

3

15,8

44

700

460

300

35

MaxiTerm MaxiTerm MaxiTerm

Page 13: Catalog Produse Termet (en)_tq0u1y (1)

Wall-hanging Boilers

www.termet.com.pl

12

One-function boilers

Technical features:

UniCo 13 GCO-13-00

- Opened combustion chamber

- Power- 4-13 kW

UniCo 24 GCO-24-00

- Opened combustion chamber

- power- 7-24 kW

UniCo 13 turbo GCO-24-01-13

- Closed combustion chamber - power- 4-13 kW

UniCo 21 turbo GCO-24-01-21

- Closed combustion chamber - power- 7-21 kW

UniCo 24 turbo GCO-24-01-24

- Closed combustion chamber

- power- 7-24 kW

UniCo 24 turbo GCO-24-01-29

- Closed combustion chamber

- power- 10-29 kW

UniCoUniCo UniCoUniCo

- Multifunction control panel with digital display

- Full auto-diagnotic system through error codes

- Cooperation with d.h.w. tank by three-way valve

- Possibility of D.H.W. temperature regulation in tank

directly from boilers control panel

- Electronic thermo manometer

- Weather regulation function accesible

- Anti-legionella’ function- water in a tank will be

automatically heated to temperature which protects water

from legionella bacteria

- Electronic ignition with ionization flame’s control

- Soft ignition function

- Complete system of preventions

- Adjustment to every gas kind of gas

Accessories:

Outside temperature

sensor

NTC sensor

to hot water

tank

Three-way

valve

Wireless temperature

regulator termet

termet

Output power in central heating circuit

Boiler efficiency

Maximum working temperature

Regulated temperature

Expansion tank capacity

Expansion tank pressure

Maximum central heating water pressure

Protection level

Chimney connection

Height

Width

Depth

TECHNICAL DATA

kW

%

C

C

l

bar

bar

IP

mm

mm

mm

mm

4 - 13,5

91,8

95

40-85

6

0,8

3

44

700

360

330

Ø 110

0

0

UniCo

Type

Ø80/125 or Ø60/100 or 2x Ø80

UniCo 13 UniCo 24 UniCo 13 UniCo 21 UniCo 24 UniCo 29

turbo turbo turbo turbo

7 - 24

91,6

95

40-85

6

0,8

3

44

700

360

330

Ø 130

4 - 13

92,1

95

40-85

6

0,8

3

44

700

360

330

7 - 21

91,3

95

40-85

6

0,8

3

44

700

360

330

7 - 24

92,3

95

40-85

6

0,8

3

44

700

360

330

7 - 29

91,4

95

40-85

6

0,8

3

44

700

360

330

Page 14: Catalog Produse Termet (en)_tq0u1y (1)

Instantaneous water heaters

www.termet.com.pl

13

Instantaneous water heaters

a ua comfort Q g-19-03a ua comfort g-19-03Q

Technical features:

aqua comfort g-19-03

- Opened combustion chamber

- Linearly- regulated power from 3,4 to 19,2 kW

aqua comfort turbo g-19-03

- Closed combustion chamber

- Linearly- regulated power from 7kW to 21 kW

and 7kW to 23 kW

- Electronic ignition (open combustion chamber from

batteries and closed one supplied 230v)

- Water temperature regulation with only two buttons

- LED display which controls d.h.w. temperature

- Modern and durable water-gas panel

- Very silent work

- New generation copper heat exchanger

- System of preventions

- Ignition by very low water pressure- 10 kPa

- Adjustment to every type of gas combustion

Precise water heating to demanding temperature and its

keeping independently from stream size in statutory range

Power

Thermal efficiency

Maximum water presure

Water temperature regulation

Maximum D.H.W. temperature

Protection level

Chimney connection

Gas connection

Cold water connection

Hot water connection

Height

Width

Depth

Weight

TECHNICAL DATA

kW

%

bar

C

C

IP

inch

inch

inch

mm

mm

mm

kg

mm

3,4-19,2

89

0,2-6

35-60

60

44

132

g 3/4

g 1/2

g 1/2

585

360

220

10,5

Ø

0

0

a ua comfort Q g-19-03a ua comfort g-19-03Q

7-21

87

0,1-6

35-60

60

44

g 3/4

g 1/2

g 1/2

587

360

220

13

3,4-19,2

89

0,2-6

35-60

60

44

g 3/4

g 1/2

g 1/2

587

360

220

13

turbo turboaqua comfort

Ø80/125 or Ø60/100 or 2x Ø80

Page 15: Catalog Produse Termet (en)_tq0u1y (1)

Instantaneous water heaters

www.termet.com.pl

14

Instantaneous water heaters

terma electronic Q g-19-02terma electronic g-19-02Qterma aqua-power Q g-19-02terma aqua-power g-19-02Qterma Q g-19-01terma g-19-01Q

TECHNICAL DATA

termaQ

Type 24/24g-19-02

electronic

g-19-01

Power

Thermal efficiency

Maximum water presure

D.H.W. stream Dt= 50 C

D.H.W. stream Dt= 25 C

Maximum D.H.W. temperature

Protection level

Chimney connection

Gas connection

Cold water connection

Hot water connection

Height

Width

Depth

Weight

kW

%

bar

l/min

l/min

C

IP

inch

inch

inch

mm

mm

mm

kg

mm

7,7-19,2

87

0,2-6

2,8-5,7

5,7-11,5

65

44

132

g 3/4

g 1/2

g 1/2

585

360

220

10,5

0

0

0

4,8-19,2

87

0,1-6

2,8-5,7

5,7-11,5

65

44

132

g 3/4

g 1/2

g 1/2

585

360

220

10,5

Technical features:

- termaq electronic *

- electronic ignition from batteries

- termaq aqua-power *

-electronic ignition with hydro-generator

-termaq **

-piezoelectric ignition

- Attractive design

- Very silent work

- Diodes wich signalize: green one - current working state

of heater, red one - battery power *

- Ergonomic and fluently revolving water and gas

expense`s dials

- Additional, hand power and water expense regulation

- New generation copper heat exchanger and new burner

- System of preventions

- Automatically regulated power from 7,7kW to 19,2 kW *

and 4,8kW to 19,2 kW **, what lets user receive steady

water temperature, independently from it`s flowing size

- Ignition by very low water pressure- 10 kPa

- Adjustment to every type of gas combustion

Page 16: Catalog Produse Termet (en)_tq0u1y (1)

Cast - iron standing boilers

www.termet.com.pl

One-function boilers

Technical features:

TermoComfort nb 3v

- Power- 15-22 kW

TermoComfort nb 4v

- power- 20-29 kW

- Cast-iron heat exchanger

- Electronic direct ignition

- Gas-fired automation with fluent power regulation

- Circulating pump- to the central heating system

- Cooperation with free-standing domestic hot water tanks

- temperature control directly from control panel

- electronic control panel with auto-diagnostic

- Diaphragm compensating tank

- Weather regulation function accesible

- Complete system of preventions

- Adjustment to every kind of gas.

TermoComfort nb 3v, nb 4vTermoComfort nb 3v, nb 4v

TECHNICAL DATA

kW

-

%

bar

C

dm

IP

mm

mm

mm

mm

kg

15,5-22

-

91

3

45-85

12

44

865

485

610

106

Ø 130

TermoComfort nb 3v nb 4v

3

0

20,5-29,3

-

91

3

45-85

12

44

865

560

610

120

Ø 130

Output power in central heating circuit

Output power in domestic hot water circuit

Boiler efficiency

Maximum water presure

Central heating temperature

Expansion tank capacity

Protection level

Chimney connection

Height

Width

Depth

Weight

15

Page 17: Catalog Produse Termet (en)_tq0u1y (1)

Cast - iron standing boilers

www.termet.com.pl

16

Two-function boilers

TermoComfort PAB 3v, PAB 4vTermoComfort PAB 3v, PAB 4v

Technical features:

TermoComfort PAB 3v

- Power- 15-22 kW

TermoComfort PAB 4v

- power- 20-29 kW

- Cast-iron heat exchanger

- 100 liters Domestic hot water tank built in

- Two circulating pumps- to the central heating system and

to the domestic hot water system

- Domestic hot water production: 013,8 l /min by Dt= 30 C

- Electronic direct ignition

- Gas-fired automation with fluent power regulation

- temperature control directly from control panel

- electronic control panel with auto-diagnostic

- Diaphragm compensating tank

- Weather regulation function accesible

- Complete system of preventions

- Adjustment to every kind of gas.

TECHNICAL DATA

kW

kW

%

bar

bar

C

C

dm

IP

mm

mm

mm

mm

kg

15,5-22

27

91

3

0,6-6

60

45-85

12

44

1480

640

700

160

Ø 130

TermoComfort nb 3v nb 4v

3

0

20,5-29,3

27

91

3

0,6-6

60

45-85

12

44

1480

640

700

173

Ø 130

Output power in central heating circuit

Output power in domestic hot water circuit

Boiler efficiency

Maximum water pressure

Maximum water pressure in d.h.w. circuit

Maximum temeperature in tank

Central heating temperature

Expansion tank capacity

Protection level

Chimney connection

Height

Width

Depth

Weight

0

termet

termet

termet

termet

Wireless temperature

regulator

Twenty - four hour

temperature regulator

Weekly temperature

regulator

termet 1310

termet 2510

termet 3000 TX

Accessories:

Page 18: Catalog Produse Termet (en)_tq0u1y (1)

Domestic hot water tanks

www.termet.com.pl

17

Domestic hot water tanks

TERMET 120 TERMET 140 TERMET TERMET

Technical features:

TERMET 120

- capacity 120 liters

TERMET 140

- capacity 140 liters

- Modern perpendicular shape

- Ergonomic way of connecting tank with boiler

- Hosepipe’s power: 120 l- 35 kW

140 l- 43,5 kW

- Domestic hot water production: 13 l/min (termet 120 )

16 l/min (termet 140 )

- Tank is made of steel sheet metal, covered with special

ceramic enamel from the outside, which provides very

good quality of heating water

- Magnesium anode built in

- Upper and lower chamber made of plastic

- TERMET 120 and TERMET 140 tanks are destined to the

cooperation with the one-function boilers produced by

Termet company (condensing boilers, wall-hanging boilers)

Capacity

Hosepipe`s surface

Hosepipe’s capacity

Domestic hot water efficiency

80/10/45 C

70/10/45 C

60/10/45 C

Permanent heating power

80/10/45 C

70/10/45 C

60/10/45 C

Central heating water request

Tank’s working parameters

Container’s weight without water

Height

WE – heating water power supply

WY – heating water come back

CR – circulation

ZW – cold water

CW – hot water

CT – temperature sensor

TECHNICAL DATA

dm

m

dm

dm /min

kW

m /h

kg

mm

120

1,3

6,0

13

9,8

7,3

35

26

20

3

69

1190

G outside 3/4''

G outside 3/4''

G outside 3/4''

G outside 3/4’

G outside 3/4'''

Ø16

0

TERMET 120 140

0

0

0

0

0

3

3

2

3

3

140

1,6

7,4

16

12

9

43,5

32,5

24,5

3

77

1350

G outside 3/4''

G outside 3/4''

G outside 3/4''

G outside 3/4'’

G outside 3/4''

Ø16

termet

TYPE ZWU- 200/N

- Capacity of tank- 200

liters

- Hosepipe’s power in 200

liters tank- 31 kW ( for

central heating

temperature- 60 C, supply

temperature- 10 C and

domestic hot water

temperature- 45 C)

0

0

0

Page 19: Catalog Produse Termet (en)_tq0u1y (1)

DesignEcology

TechnologyModernity

www.termet.com.pl

termet

note:termet s.a.ul. Wa³brzyska 3358-160 ŒwiebodzicePOLAND

EXPORT DEPARTMENT: tel. + 48 074 85-46-890 e-mail: [email protected]

18

Page 20: Catalog Produse Termet (en)_tq0u1y (1)

DesignEcology

TechnologyModernity

www.termet.com.pl

termet