Catalog Po Ak 2015

Embed Size (px)

Citation preview

  • 7/26/2019 Catalog Po Ak 2015

    1/38

    2015.04Catalogue

    TRIOL Articial Lift Surface Equipment

    www.triolcorp.com

  • 7/26/2019 Catalog Po Ak 2015

    2/381

    Introduction

    Dear customer!

    The present catalogue covers articial lift surface equipment Triol AK series forcontrol and protection of submersible electric motors. It contains information relatedto application, functionality, technical characteristics, connection diagrams, andoverall dimensions.

    For your convenience the products are divided into two sections containinginformation about models with NEMA enclosures and with IP43 enclosures for indoor/outdoor installation in a cold climate (according to industry standard GOST 15150-69).The catalogue covers three series, AK01, AK02, and AK06, with detailed descriptions forall models. Our equipment is a good solution for specic environmental conditions ofMiddle East, Asian Pacic, South America and Siberia.

    Triol Corporation successfully combines experience and innovation. We providedevelopment, production, reliable supply and after-sales service throughout the world.

    We appreciate our Partners and Customers and are always open for cooperation!

  • 7/26/2019 Catalog Po Ak 2015

    3/382

    Versions of variable speed drive Triol AK

    Equipment for submersible

    motors

    Triol AK01

    series

    Type

    GOST 15150-69

    Type

    NEMA 250.1.

    IP43, outdoors,

    cold climate NEMA3

    NEMA4X

    NEMA4

    380 V 480 V

    660 V 4 kV

    1 5 kV

    380 V 380 V

    480 V

    6-pulse, FPWM

    6-pulse, 6-step

    12-pulse, FPWM

    12-pulse, 6-step

    active input filter, FPWM

    480 V / 380 V380 V

    filtered PWM output

    for permanent magnet motors

    for induction and permanent magnet motors

    active input filter

    active input filter, filtered PWM output

    500 V / 380 V

    6-pulse, Filtered PWM output

    activefront-end

    NEMA3

    NEMA4X

    NEMA4

    NEMA3

    NEMA4X

    NEMA4

    Triol AK02

    series

    Triol AK06

    series

    Triol AK06

    series

    Triol AK02

    series

    Triol AK01

    series

    linear permanent magnet motors

    480 V

    IP43, outdoors,

    cold climate

    IP43, outdoors,

    cold climate

    6-pulse, FPWM

    active input filter, FPWM

  • 7/26/2019 Catalog Po Ak 2015

    4/38

  • 7/26/2019 Catalog Po Ak 2015

    5/38

    AK**-XX-Y1Y2Y3Y4Y5Y6-Z-

    4

    Product code structure

    Triol AK** series01 Switchboard (D.O.L. motor starter).02 Soft starter.06-AM Variable speed drive for induction motor.06-AH Variable speed drive for high speed induction motor.06-PC Variable speed drive for progressive cavity pumps.06-PM Variable speed drive for permanent magnet motor.06-PH Variable speed drive for high-speed permanent magnet motor.06-MM Variable speed drive for induction or permanent magnet motor(multipurpose version).06-SM Variable speed drive for synchronous motor.06-LL Variable speed drive for linear permanent magnet motors.06-ASPED Variable speed drive with automated system providing oil production

    eciency increase.

    Type of equipment (X)

    Type of Triol AK Rated current, A

    100 100

    160 160

    250 250

    400 400

    630 630

    800 80010 1000

    12 1200

    14 1400

    16 1600

    18 1800

    20 2000

    25 2500

    32 3200

    tro

  • 7/26/2019 Catalog Po Ak 2015

    6/38

    AK**-XXX-Y1Y2Y3Y4Y5Y6--Z

    5

    Rectier type (Y1)

    0 Thyristor-thyristor six-pulse bridge rectier1 Transistor active front-end

    2 Half-controlled six-pulse bridge rectier3 Half-controlled twelve-pulse bridge rectier4 Half-controlled eighteen-pulse bridge rectier5 Soft starter without frequency converter6 Uncontrolled six-pulse bridge rectier7 Passive input grid lter8 With active lter

    Sinewave lter (Y2)

    0 Without build-in sine output lter1 With build-in sine output lter

    Bypass system (Y3)

    0 Without bypass device1 With bypass (optional)

    Enclosure climatic version (Y4)

    0 Enclosure type for cold and moderate climates (1 according to GOST 15150-69)1 Enclosure type for tropical dry zone (IP43, outdoor, cold climate)2 Operating conditions according to EN 61439-1:2010 for outdoor installation.Custom climatic version.

    Controller type (Y5)

    0 Without controller1 Provision for connection to a third party controller2 Modication upon customer request3 With UMKA-03 controller4 With UMKA-04 controller5 With UMKA-05 controller

    Modication (Y6)

    0 VSD basic modication

    1...9 customized modication based on the clients requirements

    Meter type ()

    SET meter SET-4MER meter MerkuriyENM meter Energomer

    Supply voltage (Z)

    380 supply voltage of 380 V480 supply voltage of 480 V660 supply voltage of 660 V4000 supply voltage of 4000 V5000 supply voltage of 5000 V

    Intro

  • 7/26/2019 Catalog Po Ak 2015

    7/38

  • 7/26/2019 Catalog Po Ak 2015

    8/38

    NEMA type

    Intro

    7

    Triol Corporation has made a step forward by releasing products with protectionclasses NEMA 3, 4, and 4X according to standard NEMA 250.1.

    Equipment with NEMA 3 enclosures is intended for indoor and outdoor use and provides

    protection against rain and snow. The enclosure also protects the user from accidentalcontact with live parts. In general it exceeds the performance requirements of IP55.

    Equipment with NEMA 3 enclosures is intended for outdoor use and providesprotection against dust and moisture similar to IP66 in the temperature range fromminus 20 to +60C (4 to +140F). The NEMA4X diers from NEMA4 in its corrosionresistance.

    To satisfy the requirements of class NEMA4/4X Triol Corporation has developedan air-tight cabinet with a special type of covering that withstands all necessary tests.For the most demanding applications there is a version with the cabinet made ofstainless steel which provides unique protection from corrosive medium and is suitablefor equipment to be used at manufacturing plants or oshore platforms.

    The NEMA4 protection class of VSD AK series is provided by: Special corrosion-resistant fans that are also resistant to dust and sand; Built-in heat exchangers for removing heat from the power compartment providing

    operation at ambient temperatures of up to +60C (+140F); Dust and sand catchers allow operation of the cooling system in dusty environments; Corrosion resistance of the enclosure is provided by a special paint coating while

    that of the DC-link chokes is provided by special compound they are impregnatedwith (for NEMA4);

    The highest corrosion resistance is provided by an enclosure made of stainless

    steel while the cooled DC-link chokes are impregnated with special compound(for NEMA4H);

    To remove moisture from air-tight compartments special unidirectional IP66diaphragms and dehumidier based on Peltier elements are used.

  • 7/26/2019 Catalog Po Ak 2015

    9/388

    Input section topology

    6 pulse rectier

    Supplymains

    connection

    ABC

    Output 3-phases voltage

    U V W

    The power circuit with 6-pulse rectier (Graetz bridge) is shown in the Figure. With thistopology there is voltage ripple with a frequency of 300 Hz at the output of the rectierbridge. For smoothing the current waveform an LC-lter is applied. The lter reducesharmonic emission into the power network.

    When using AK VSDs in networks with strict requirements to waveform distortion it isrecommended to use a three-phase lter.

    12 pulse rectier

    Supplymains

    connection

    Supplymains

    connection

    Output 3-phases voltage

    A1B1C1

    U V W

    A2

    B2C2

    The 12-pulse rectier is the most widespread solution at the moment as it is muchbetter than 6-pulse scheme in terms of harmonic emission into the mains.

    There are two versions of the four-winding isolation transformers available: dry type(for indoor installation) and oil type (for outdoor installation). This gives maximum

    exibility when selecting a solution depending on the available oor space, installationcosts, and permissible load on the air-conditioning system used to maintain the desiredroom temperature.

    tro

  • 7/26/2019 Catalog Po Ak 2015

    10/389

    Active Harmonic Filter

    ABC

    U V W

    Supplymains

    connection

    Output 3-phases voltage

    Presence of non-linear loads causes the higher order harmonics (5, 7, 11, and higher)to appear in the network. It has a negative eect on equipment as a whole (additionalheating of wiring, inecient use of energy, reducing life of insulation, overheating oftransformers, etc.)

    To limit such distortions appropriate technologies and standards were introduced. Thisprocess has been quite successful in the sense that the problems faced by consumersalmost always arise due to the conditions that appear in their own area of responsibility,and only rarely are brought from the mains. If this situation continues consumers will haveto limit the level of harmonic current created by their equipment. Consequently consumeris the one who should provide ltering of harmonic components where necessary.

    There are several methods of reducing the harmonic currents owing into the mainsduring operation of semiconductor converters. One of such methods is the use of passiveresonant lters that are bulky and have some other shortcomings.

    A more advanced method is the active interference suppression which is achieved byinjecting into the network harmonic currents that are equal to those already present inthe network but are opposite in phase.

    Total harmonic distortion in the input current for this VSD is less than 5% which totallycomplies with IEEE519. The AK06 VSD with active harmonic lters does not need bulkypassive lters or use of 12, 18, or 24-pulse phase shifting transformers, since it can be fedfrom an ordinary two winding transformer (one primary and one secondary windings).

    Also the active lter provides fast response to changes in current harmonic compositionresulting in the most eective interference suppression.

    Intro

  • 7/26/2019 Catalog Po Ak 2015

    11/38

    N-10

    .01

    AK01--500241- Switchboard

    Application

    Triol AK01 starter with NEMA3/4/4X enclosure, 660 V ... 4 kV, is a reliable, safe and low costsolution for controlling submersible motors with 600 V to 4 kV voltage ratings.

    Rated voltage

    Rated inputvoltage, V

    Rated outputcurrent, A

    Rated power ofmotor, kW

    Rated power ofmotor, hp

    Ordering code

    660 4000200 100 135.96 01-200-500241-

    400 200 271.92 01-400-500241-

  • 7/26/2019 Catalog Po Ak 2015

    12/38N-11

    N.01

    Host offunctions

    D.O.L. start of submersible pump motors; Re-start blocking during motor rundown (rundown delay); Local and remote control of operating modes; Protection against short-circuit currents and overloads;

    Provision for control with feedback from a submersible transducer; Protection settings may be checked and changed via RS-485; Operation in two modes: Manual and Automatic; Measurement of active energy, reactive energy, and total energy consumption; Automatic pump switching on with an adjustable time delay (from 1 to 9999 minutes)

    after supply voltage is applied; Motor operation blocking in case of wrong phase sequence on the input of the starter; Motor operation blocking if the supply voltage is out of tolerance; Motor tripping with further automatic restart in case of severe supply voltage deviations

    (higher or lower by more than 25% of the rated value) causing an overcurrent condition; Motor tripping when any phase is underloaded with selectable minimum phase current

    and time delay; Motor tripping in case of overload according to programmable time-current characteristic; Automatic restart of motor after tripping by underload protection with preset time delay

    (from 1 to 9999 minutes); Operation mode setting: with automatic restart after a trip or without automatic restart

    after a trip; Motor operation blocking if the pump is caused to rotate by ow of liquid (turbine

    rotation) with selectable frequency threshold; Automatic blocking of manual turning on and control while operating with external

    process control system;

    Automatic restart after fault; Selection of operation with automatic periodic turning the motor on and o according

    to preset timing diagram (from 1 to 28800 minutes); Continuous monitoring of motor and cable insulation resistance with tripping if

    the resistance drops below the threshold value; Possibility of operation with decreased cable and motor resistance and fast tripping

    under overload conditions; Light indication of D.O.L. starter operating mode (run, wait, stop); Light indication in case of emergency stop; Monitoring of the motor current and supply-line voltage;

    Provision for tuning at site: overload/underload protection, supply line over- andundervoltage protection (operation threshold setting); Embedded memory for recording of current parameters during operation of the pump; Displaying on the screen: motor current, supply-line voltage, all presets, operating

    modes including operation of protections, time to switching on/o in automatic modewith timer, time to trip when protection thresholds are exceeded,

    Recording of motor tripping time and its cause; Tripping the motor and restart blocking when supply-line voltage imbalance protection

    threshold is exceeded; Tripping the motor when the current imbalance protection threshold is exceeded; D.O.L. starter control basing on additional technical parameters: pump temperature,

    pressure, and pumping unit vibration.

  • 7/26/2019 Catalog Po Ak 2015

    13/38

    N-12

    .01

    AK01--500241- Switchboard

    Technical characteristicsMain characteristics

    Voltage, V 660...4000, +10 %, -10 %

    Frequency, Hz 50 ... 60Enclosure NEMA3 NEMA4X

    Operation temperature -20 ... +60 / 4 ... 140F

    Rectication type without recier

    Analog inputs 2

    Digital inputs (opto-isolated,220 V a.c.)

    2

    Altitude characteristics up to 1000 m / 3280 ft

    Standards NEMA 250-2008, GOST 17516.1-90

    Protection functions

    Alarms and protections

    external and internal short-circuit

    underload (trip on underload)

    open-phase fault of input or output circuits

    motor overload

    power supply or control system fault

    turning on at too low controller temperature

    interlock preventing unauthorized access to

    DOL starter settings

  • 7/26/2019 Catalog Po Ak 2015

    14/38N-13

    N.01

    External connection diagram

    ESP ON

    Control of the ESM

    Digital inputs

    Connecting TMS via RS-485

    Internal power supply telemetry

    Connecting an external automation

    system via RS-485

    External ban

    Ain 1

    Ain 2Ain common

    ACS RS485 A+

    ACS RS485 B-

    ACS RS GND

    ESP general

    ESP OFF

    +24 VPressure gauge

    +24 V

    Common analog input

    Signal wire A RS485

    5

    2

    TMS RS485 A+

    TMS RS GND

    TMS RXD

    TMS TXD

    TMS GND

    Signal wire A RS485

    Admission RS-232 data

    ~220 V

    ~220 V

    Data transmission RS-232

    Neutral wire RS232

    ~220 V

    ~220 V

    Net

    Net

    TMS RS485 B-

    ACVOT

    Output U

    Output V

    Output W

    Shield

    Ground

    Input3-phase

    powercircuit

    Neutral

    Phase C

    Phase B

    Phase A

    Description Appointment

    Normally closed contacts

    Common contact

    Normally opened contacts

    Digital input 1

    Digital input 2

    Analog input 1

    Analog input 2

    Signal wire B RS485

    Neutral wire RS485

    Power supply of digital inputs

    Description Appointment

    Signal wire B RS485

    Neutral wire RS485

    Telemetry connection

    ESM

    Circuit diagram

    CasingCasing

    Step-uptransforme

    Output W

    Output V

    Output V

    Output terminals

    Circuit

    Circuit

    Terminal of external connections

    Socket

    Power switchQF1

    Phase A

    Phase B

    Phase C Contactor

    Inputterminals

    Circuit

    Circuit

    Circuit

    ESMON

    ESMcommon

    ESMOFF

    +24V

    Cont.pres.gauge

    Externalblocking

    Ain1

    Ain2

    Aincommon

    ACSRS485A+

    ACSRS485B

    ACSRSGND

    1 2 3 4 5 6 7 8 9 10

    11

    12

    TMSTXD

    TMSRXD

    TMSGND

    RS485A

    RS485B

    RS485GND

    1 2 3 1 2 3

    A1

    A2

    33

    34

    31

    32

    43

    44

    41

    42

    220V AC, 50Hz

    220V AC, 50Hz

    NO 1.1

    NO 1.2

    NC 1.1

    NC 1.2

    NO 2.1

    NO 2.2

    NC 2.1

    NC 2.2

    1

    2

    220V AC

    220V AC

    FU1

    FU3

    FU2

    1L1

    5L3

    3L2

    1L1

    5L3

    3L2

    2T1

    6T3

    4T2

    KM1

    TA1

    TA2

    TA3

    SA1

  • 7/26/2019 Catalog Po Ak 2015

    15/38

    N-14

    .01

    AK01--500241- Switchboard

    840 mm (33.07 in)

    12 mm (0.472 in)

    380mm

    (14.9

    6in)

    760mm(

    29.9

    2in)

    1815mm(

    71.4

    6in)

    1330 mm (52.36 in) 1035 mm (40.75 in)

    985mm(

    38.7

    8in)

    535mm

    (21.0

    6in)

    1497mm(

    58.9

    4in)

    Dimensions

    Height of cable connection points

  • 7/26/2019 Catalog Po Ak 2015

    16/38N-15

    N.01

    max 90

    Sling arrangement

    2518 mm (99.13 in)

    2720mm(

    107.09

    in)

    Overall dimensions with open door(s) + door opening clearances

  • 7/26/2019 Catalog Po Ak 2015

    17/38

    N-16

    .01

    AK01--500241- Switchboard

    Application

    Triol AK01 starter with NEMA3/4/4X enclosure, 1 5 kV, is a reliable, safe and low costsolution for controlling submersible motors with voltage ratings from 1 kV to 5 kV.

    Rated voltage

    Rated inputvoltage, V

    Rated outputcurrent, A

    Rated power ofmotor, kW

    Rated power ofmotor, hp

    Ordering code

    1 5000200 100 135.96 01-200-500241-

    400 200 271.92 01-400-500241-

  • 7/26/2019 Catalog Po Ak 2015

    18/38N-17

    N.01

    Host offunctions

    Motor switching on/o; Motor operation in the following modes: Manual (without automatic restart after

    a trip); Automatic with automatic restart after a trip, and Automatic with operationaccording to preset timing diagram;

    Current optimization after reaching a preset value of the motor frequency; Manual control of motor speed from UMKA-03 controller and remote control froma dispatching point;

    Automatic change of the output frequency according to a preset timing diagram; Motor automatic starting after selectable delay when the supply voltage is applied; Automatic maintaining of some process parameters (pressure, current) at their setpoints; Measurement and indication of current parameters of submersible pump and VSD on

    the integrated liquid-crystal display; Motor remote control, monitoring of motor parameters, uploading and downloading

    of protection settings through telemetering system (downhole measured equipment)via RS485 interface;

    Recording of trip events and corresponding current parameters into the integratednonvolatile memory;

    Recording of modied settings into the event log with date and time corresponding tosuch modication;

    Outdoor light alarm system indicating the pumping unit condition (run, wait, stop); Motor control with feedback from a submersible transducer; Congurable integrated protections: overload/underload, current imbalance, supply

    voltage and DC-link voltage outside allowable limits, continuous operation at lowfrequency, power semiconductor overheating, operation at abnormal values ofparameters controlled by telemetering system (downhole);

    Monitoring of input phase voltages. The drive is tripped or motor start is inhibited ifphase-loss condition is detected.

  • 7/26/2019 Catalog Po Ak 2015

    19/38

    N-18

    .01

    AK01--500241- Switchboard

    Technical characteristicsMain characteristics

    Voltage, V 1000...5000, +10 %, -10 %

    Frequency, Hz 50 ... 60Enclosure NEMA3 NEMA4X

    Operation temperature -20 ... +60 / 4 ... 140F

    Rectication type without rectier

    Analog inputs 2

    Digital inputs (opto-isolated,220 V a.c.)

    2

    Altitude up to 1000 m / 3280 ft

    Standards NEMA 250-2008, GOST 17516.1-90

    Protection functions

    Alarms and protections

    tripping in case of supply voltage deviation if suchdeviation results in overcurrent condition (withpossibility of auto-restart after voltage recovery)

    overcurrent protection (OCP)

    IGBT de-saturation protection

    protection against current imbalance

    motor overload protection

  • 7/26/2019 Catalog Po Ak 2015

    20/38N-19

    N.01

    External connection diagram

    ESP ON

    Control of the ESM

    Digital inputs

    Connecting TMS via RS-485

    Internal power supply telemetry

    Connecting an external automation

    system via RS-485

    External ban

    Ain 1

    Ain 2Ain common

    ACS RS485 A+

    ACS RS485 B-

    ACS RS GND

    ESP general

    ESP OFF

    +24 VPressure gauge

    +24 V

    Common analog input

    Signal wire A RS485

    5

    2

    TMS RS485 A+

    TMS RS GND

    TMS RXD

    TMS TXD

    TMS GND

    Signal wire A RS485

    Admission RS-232 data

    ~220 V

    ~220 V

    Data transmission RS-232

    Neutral wire RS232

    ~220 V

    ~220 V

    Net

    Net

    TMS RS485 B-

    ACVOT

    Output U

    Output V

    Output W

    Shield

    Ground

    Input3-phase

    powercircuit

    Neutral

    Phase C

    Phase B

    Phase A

    Description Appointment

    Normally closed contacts

    Common contact

    Normally opened contacts

    Digital input 1

    Digital input 2

    Analog input 1

    Analog input 2

    Signal wire B RS485

    Neutral wire RS485

    Power supply of digital inputs

    Description Appointment

    Signal wire B RS485

    Neutral wire RS485

    Telemetry connection

    ESM

    Circuit diagram

    CasingCasing

    Step-uptransforme

    Output W

    Output V

    Output V

    Output terminals

    Circuit

    Circuit

    Terminal of external connections

    Socket

    Power switchQF1

    Phase A

    Phase B

    Phase C Contactor

    Inputterminals

    Circuit

    Circuit

    Circuit

    ESMON

    ESMcommon

    ESMOFF

    +24V

    Cont.pres.gauge

    Externalblocking

    Ain1

    Ain2

    Aincommon

    ACSRS485A+

    ACSRS485B

    ACSRSGND

    1 2 3 4 5 6 7 8 9 1

    0

    1

    1

    1

    2

    TMSTXD

    TMSRXD

    TMSGND

    RS485A

    RS485B

    RS485GND

    1 2 3 1 2 3

    A1A2

    33

    34

    31

    32

    43

    44

    41

    42

    220V AC, 50Hz220V AC, 50Hz

    NO 1.1

    NO 1.2

    NC 1.1

    NC 1.2

    NO 2.1

    NO 2.2

    NC 2.1

    NC 2.2

    1

    2

    220V AC

    220V AC

    FU1

    FU3

    FU2

    1L1

    5L3

    3L2

    1L1

    5L3

    3L2

    2T1

    6T3

    4T2

    KM1

    TA1

    TA2

    TA3

    SA1

  • 7/26/2019 Catalog Po Ak 2015

    21/38

    N-20

    .01

    AK01--500241- Switchboard

    840 mm (33.07 in)

    12 mm (0.472 in)

    380mm

    (14.9

    6in)

    760mm(

    29.9

    2in)

    1815mm(

    71.4

    6in)

    1330 mm (52.36 in) 1035 mm (40.75 in)

    985mm(

    38.7

    8in)

    535mm

    (

    21.0

    6in)

    1497mm(

    58.9

    4in)

    Dimensions

    Height of cable connection points

  • 7/26/2019 Catalog Po Ak 2015

    22/38N-21

    N.01

    max 90

    Sling arrangement

    2518 mm (99.13 in)

    2720mm(

    107.0

    9in

    )

    Overall dimensions with open door(s) + door opening clearances

  • 7/26/2019 Catalog Po Ak 2015

    23/38

    N-22

    .06

    06-AM--110231-480 Variable speed drive

    Application

    Triol AK06 variable speed drive with 6-pulse rectier and ltered PWM output,NEMA3/4/4X enclosure, 480 V, with system integration options for submersible pumpapplications. The drive provides enhanced motor performance and reliability.

    Rated voltage

    Ratedinput

    voltage, V

    Rated outputcurrent, A

    Rated powerof motor, kW

    Rated power ofmotor, hp

    Ordering code

    480

    100 70 95.17 06-AM-100-110231-480

    160 100 135.96 06-AM-160-110231-480

    250 200 271.92 06-AM-250-110231-480

    400 330 448.67 06-AM-400-110231-480630 520 706.99 06-AM-630-110231-480

    800 660 897.34 06-AM-800-110231-480

    1000 830 1128.47 06-AM-10-110231-480

    1200 995 1352.80 06-AM-12-110231-480

    1400 1160 1577.14 06-AM-14-110231-480

    1600 1330 1808.27 06-AM-16-110231-480

    1800 1495 2032.60 06-AM-18-110231-480

  • 7/26/2019 Catalog Po Ak 2015

    24/38N-23

    N.06

    Host offunctions

    Motor switching on/o; Motor operation in the following modes: Manual (without automatic restart after

    a trip); Automatic with automatic restart after a trip, and Automatic with operationaccording to preset timing diagram;

    Current optimization after reaching a preset value of the motor frequency; Operation according to pre-programmed timing diagram with motor ON/OFF periodsprogrammed separately;

    Manual control of motor speed from UMKA-03 controller and remote control fromsupervisory control console;

    Automatic change of the output frequency according to a preset timing diagram; Motor acceleration and deceleration at preset rates (acceleration and deceleration ramps); Motor reversal; Motor automatic starting after selectable delay when the supply voltage is applied; Automatic maintaining of some process parameters (pressure, current) at their setpoints; Selectable motor starting modes: swinging, impact start (may be used for unjamming

    the submersible unit), soft start with synchronization. Unjamming is done with maximumpossible motor torque at low speed;

    Continuous monitoring of motor and cable insulation resistance with tripping ifthe resistance drops below the threshold value;

    Possibility of operation with decreased cable and motor resistance and fast trippingunder overload conditions;

    Measurement and indication of current parameters of submersible pump and VSD onthe integrated liquid-crystal display;

    Motor remote control, monitoring of motor parameters, uploading and downloadingof protection settings through telemetering system (downhole measured equipment)

    via RS485 interface; Recording of trip events and corresponding current parameters into the integrated

    nonvolatile memory; Recording of modied settings into the event log with date and time corresponding to

    such modication; Outdoor light alarm system indicating the pumping unit condition (run, wait, stop); Motor control with feedback from a submersible transducer; Congurable integrated protections: overload/underload, current imbalance, supply

    voltage and DC-link voltage outside allowable limits, continuous operation at lowfrequency, power semiconductor overheating, operation at abnormal values of para-

    meters controlled by telemetering system; Opening of the VSD door may be signalized to dispatching station through telemetering

    system (downhole); Measurement of electric energy consumption; Monitoring of input phase voltages. The drive is tripped or motor start is inhibited if

    phase-loss condition is detected.

  • 7/26/2019 Catalog Po Ak 2015

    25/38

    N-24

    .06

    06-AM--110231-480 Variable speed drive

    Technical characteristicsMain characteristics

    Voltage, V 480 +15, -25%

    Frequency, Hz 50 ... 60Eciency, % 97

    Overload capability 125 % of the rated current for 300 seconds

    Rectication type half-controlled six-pulse (Graetz bridge)

    Analog inputs 2

    Digital inputs (opto-isolated,220 V a.c.)

    2

    Enclosure NEMA3 NEMA4X

    Operation temperature -20 ... +60 / 4 ... 140FAltitude up to 1000 m / 3280 ft

    StandardsNEMA 250-2008, GOST 17516,1-90,GOST 18058-80, GOST 15150-69,

    Protection functions

    Alarms and protections

    tripping in case of supply voltage deviation if suchdeviation results in overcurrent condition (withpossibility of auto-restart after voltage recovery)

    tripping on underload

    overload according to programmable time-currentcharacteristic

    overcurrent protection (OCP)

    tripping if motor and cable insulation resistancedrops below the threshold

    motor stall protection

    IGBT de-saturation fault protection

    tripping in case of power modules overheating

    tripping if parameters monitored by telemetering

    system exceed preset valuestripping if pipeline pressure is outside the limits(using signals from contact pressure gauge)

    tripping if power compartment door is opened

  • 7/26/2019 Catalog Po Ak 2015

    26/38N-25

    N.06

    External connection diagram

    Normally closed contacts

    ESP on

    ESP common

    ESP off

    +24 V +24 V

    Control of ESM operation

    Power supply of discrete inputs

    Pressure gauge Contact pressure gauge Digital input, contact pressure gauge

    Ain 1.1 Analog input 1

    Ain common Common analog input

    Ain 1.2 Analog input 2Connection sensors of

    submersible telemetry unit

    ACS RS485 A+

    ACS RS485 B-

    Signal cable A RS485

    Signal cable B RS485Connecting the external ACS

    by RS-485ACS RS GND Neutral wire RS-485

    Circuit Description Purpose

    Signal cable A RS485

    Signal cable B RS485

    Neutral wire RS-485

    Connect a digital telemetry

    RS-485

    Connect a digital telemetry

    RS-232Neutral wire RS232

    Data transmission RS232

    Data receiving RS232

    Telemetry power supply~ 220 V~ 220 V

    Internal/external circuit

    ACVOT-0

    If the is a jumper in this terminal, Rizis measured by variable speeddrive, not by telemetry system

    ACVOT-0

    ACVOT-0

    Casing ACVOT ESM

    Control circuit ~220 V

    GroundingGND

    Input3480V

    thereduction

    ofpowertransformer

    Circuit Description Purpose

    Circuit Description Purpose

    A

    B

    C

    Neutral

    TMS TXD

    TMS RXD

    TMS GND

    TS RS GND

    TS RS485 A+

    TS RS485 B-

    External bloking External blocking of turn-on External blocking of ESM start

    Ain 2.1 Analog input 1

    Ain common Common analog input

    Ain 2.2 Analog input 2Connection sensors of

    submersible telemetry unit

    XT9

    X3

    X5

    Din reserve Reserve digital input Reserve digital input

    Circuit diagram

    2

    2

    1

    3

    2

    1

    3

    2

    1

    3

    2

    1

    3

    6

    4

    5

    3

    1

    TA1

    TA2

    Power switchQF1

    X1 Socket

    Circuit

    220V AC

    220V AC

    1

    2

    Terminal of external connections

    X5

    X3

    ESMON

    ESMcommon

    ESMOFF

    +24V

    Cont.pres.gauge

    Externalblocking

    Ain1

    Ain2

    Aincommon

    ACSRS485A+

    ACSRS485B

    ACSRSGND

    Circu

    it

    1 2 3 4 5 6 7 8 9 10

    11

    12

    Contact pressure gauge

    TMS terminal (downhole sensors)

    1 2 3 4 5 6 7 8 9 10

    11

    12

    TMSRS485A+

    TMSRS485B-

    TMSRSGND

    TMSTXD

    TMSRXD

    TMSGND

    Ain1

    Ain2

    Aincommon

    220VAC

    220VAC

    Circu

    it

    Casing

    Casing

    Step-uptransformer

    Output W

    Output V

    Output V

    Output terminals

    Phase A

    Phase B

    Phase C

    Inputterminals

    TA3

  • 7/26/2019 Catalog Po Ak 2015

    27/38

    N-26

    .06

    06-AM--110231-480 Variable speed drive

    14 mm (0.55 in)

    983 mm (38.70 in)

    85

    5mm(

    33.6

    6in)

    2090mm(

    82.2

    8in)

    1050 mm (41.34 in)

    1360 mm (53.54 in)

    1185 mm (46.65 in)

    1350 mm (53.15 in)

    External connections Transformer secondary star point

    3-phase choke star point

    connection star point

    onnection panel

    1247mm(

    49.0

    9in)

    1286mm(

    50.6

    3in)

    1337mm(

    52.6

    4in)

    1599mm(

    62.9

    5in)

    Dimensions

    Height of cable connection points

  • 7/26/2019 Catalog Po Ak 2015

    28/38N-27

    N.06

    R224 mm (8.82 in)

    R1019 mm (40.12 in)

    R1039 mm (40.91 in)

    max 90

    Sling arrangement

    Overall dimensions with open door(s) + door opening clearances

  • 7/26/2019 Catalog Po Ak 2015

    29/38A-28

    .06

    06-LL--110231-480 Variable speed drive

    Application

    Triol AK06 variable speed drive with 6-pulse input and ltered PWM output, IP43enclosure type (outdoors, cold climate), 480 V, oers enhanced motor performance,reliability and system integration options for linear motor control ESPs.

    Rated voltage

    Ratedinput

    voltage,V

    Rated current ofpower circuit, A

    Rated powerof motor, kW

    Rated powerof motor, hp

    Catalog number

    480

    250 200 271.92 06-LL-250-110231-480

    320 265 360.29 06-LL-320-110231-480

    400 330 448.67 06-LL-400-110231-480

    500 415 564.23 06-LL-500-110231-480

    630 520 706.99 06-LL-630-110231-480

    800 660 897.34 06-LL-800-110231-480

    1000 830 1128.47 06-LL-10-110231-480

    1200 995 1352.80 06-LL-12-110231-480

    1400 1160 1577.14 06-LL-14-110231-480

    1600 1330 1808.27 06-LL-16-110231-480

    1800 1495 2032.60 06-LL-18-110231-480

  • 7/26/2019 Catalog Po Ak 2015

    30/38A-29

    A.06

    Keyfunctions

    Motor switching on/o; Motor operation in the following modes: Manual without automatic restart after

    a trip), Automatic with automatic restart after a trip, and Automatic with operationaccording to preset timing diagram;

    Current optimization mode on reaching a preset value of the motor frequency; Manual control of motor speed from UMKA-03 controller and remote control froma dispatching point;

    Automatic change of the output frequency according to a preset timing diagram; Motor automatic starting after selectable delay when the supply voltage is applied; Automatic maintaining of some process parameters (pressure, current) at their setpoints; Measurement and indication of current parameters of submersible pump and VSD on

    the integrated liquid-crystal display; Motor remote control, monitoring of motor parameters, uploading and downloading of

    protection settings through telemetering system (downhole measured equipment) viaRS485 interface;

    Recording of trip events and corresponding current parameters into the integratednonvolatile memory;

    Recording of modied settings into the event log with date and time corresponding tosuch modication;

    Outdoor light alarm system indicating the pumping unit condition (run, wait, stop); Motor control with feedback from a submersible transducer; Congurable integrated protections: overload/underload, current imbalance, supply

    voltage and DC-link voltage outside allowable limits, continuous operation at lowfrequency, power semiconductor overheating, operation at abnormal values ofparameters controlled by telemetering system (downhole);

    Monitoring of input phase voltages. The drive is tripped or motor start is inhibited ifphase-loss condition is detected.

  • 7/26/2019 Catalog Po Ak 2015

    31/38A-30

    .06

    06-LL--110231-480 Variable speed drive

    Technical characteristicsMain characteristics

    Voltage, V 480 +10, -10%

    Frequency, Hz 50 ... 60Eciency, % 97

    Overload capability 125 % of the rated current for 300 seconds

    Rectication type Half-controlled six-pulse (Graetz bridge)

    Analog inputs 2

    Digital inputs (opto-isolated,220 V a.c.)

    2

    Enclosure NEMA3 NEMA4X

    Operation temperature -10 ... +60 / 14 ... 140F

    Relative humiditynot more than 80 % at +20C(without condensation)

    Altitude up to 1000 m / 3280 ft

    StandardsNEMA 250-2008, GOST 17516,1-90,GOST 18058-80, GOST 15150-69,

    Protection functions

    Alarms and protections

    tripping in case of supply voltage deviation if suchdeviation results in overcurrent condition

    (with possibility of auto-restart after voltage)overcurrent protection (OCP)

    IGBT de-saturation protection

    protection against current imbalance

    motor overload protection

  • 7/26/2019 Catalog Po Ak 2015

    32/38A-31

    A.06

    External connection diagram

    Normally closed contacts

    ESP on

    ESP gen.

    ESP off

    +24 V +24 V

    Control of ESM operation

    Power supply of discrete inputs

    Pressure Gauge Contact pressure gauge Digital input, contact pressure gauge

    Ainput 1 Analog input 1

    Ainput gen. General analog input

    Ainput 2 Analog input 2Connection sensors of

    submersible telemetry unit

    ACS RS485 A+

    ACS RS485 B-

    Signal cable A RS485

    Signal cable B RS485Connecting the external ACS

    by RS-485ACS RS GND Neutral wire RS-485

    Circuit Description Purpose

    Casing ACVOT ESM

    GroundingGND

    Input3480V

    thereduction

    ofpowertransformer

    A

    B

    C

    Circuit diagram

    2

    2

    1

    3

    2

    1

    3

    2

    1

    3

    2

    1

    3

    6

    4

    5

    3

    1

    TA1

    TA2

    Power switchQF1

    X1 Socket

    Circuit

    220V AC

    220V AC

    1

    2

    Terminal of external connections

    X5

    X3

    ESMON

    ESM

    common

    ESMOFF

    +24V

    Cont.pres.gauge

    Extern

    alblocking

    Ain1

    Ain2

    Ain

    common

    ACS

    RS485A+

    ACS

    RS485B

    ACS

    RSGND

    Circu

    it

    1 2 3 4 5 6 7 8 9 10

    11

    12

    Contact pressure gauge

    TMS terminal (downhole sensors)

    1 2 3 4 5 6 7 8 9 10

    11

    12

    TMS

    RS485A+

    TMSRS485B-

    TMS

    RSGND

    TM

    STXD

    TM

    SRXD

    TM

    SGND

    Ain1

    Ain2

    Aincommon

    220VAC

    220VAC

    C

    ircu

    it

    Casing

    Casing

    Step-uptransformer

    Output W

    Output V

    Output V

    Output terminals

    Phase A

    Phase B

    Phase C

    Inputterminals

    TA3

  • 7/26/2019 Catalog Po Ak 2015

    33/38A-32

    .06

    06-LL--110231-480 Variable speed drive

    4 holes

    1887mm(

    74.2

    9in)

    887 mm (34.92 in) 815 mm (32.09 in)

    14 mm (0.551 in)

    606 mm (23.86 in)

    500mm(

    19.6

    9in)

    External connections compartment Intput connection panel

    Output connection panel

    Terminal

    of step-up transformer connection

    1208mm(

    47.5

    6in)

    1255mm(

    49.4

    1in)

    1208mm(

    47.5

    6in)

    Dimensions

    Height of cable connection points

  • 7/26/2019 Catalog Po Ak 2015

    34/38A-33

    A.06

    R743 mm (29.25 in)

    R200 mm (7.87 in)

    R755 mm (29.72 in)

    R237 mm

    (9.33 in)

    1512 mm (59.53 in)

    1966mm(

    77.4

    0in)

    < 90

    Sling arrangement

    Overall dimensions with open door(s) + door opening clearances

  • 7/26/2019 Catalog Po Ak 2015

    35/38N-34

    N.I

    Optional equipment

    GSM modem Triol MT01 providing remote control of the VSD (for more details visit ourwebsite www.triolcorp.com);

    Modem Fargo Maestro or any other modem that provides data exchange with the variablespeed drive via GSM protocol;

    Energy meters with RS-485; Ethernet communication unit; Safety shutdown feature (+ emergency o button). If the supply voltage disappears

    or falls below the limit (or if the emergency stop button is pressed) the VSD will beautomatically turned o;

    Uninterruptible power supply providing power for the controller for 24 hours aftera power failure. This simplies diagnostics of the VSD (determination of failure time,VSD behavior before the event, etc.);

    Communication protocols for SCADAs Triol, Region, Telescope, and Salym Pet.

    Package contents

    The NEMA type drives Triol 01, 02, and 06 are supplied with the following items: Lock keys; Hardware kit for telemetering;

    USB Flesh memory.

    VSD can be supplied with the following items (optional): Spare parts including:

    invertor unit rectier unit supply unit

    Higher-level / lower-level controllers; Reduction Power Transformers; Fuses, with accordance to VSD rated voltage and current;

    Invertor fans; Power switches; Modem kit with GSM-antennas and connection sockets; Electrical conduits for cabling in places of process facilities; Interfaces protection devices, used under pulse overloads and distortions; other equipment items, according to the Supply contract.

  • 7/26/2019 Catalog Po Ak 2015

    36/38N-35

    N.I

    Operation with downhole sensors

    The NEMA type drives Triol 01, 02, and 06 provide operation with the followingdownhole sensors:

    Triol Triol TMT produced by Triol Corporation; Borets produced by Borets LLC;

    Electon produced by Electon; Izhevsk produced by JSC Izhevsk radio manufacturing plant; WoodGroup Smartguard produced by Woodgroup; Phoenix Phoenix produced by REDA (Shlumberger); SKAD-2002 SKAD-2002 produced by BelNipineft; Novomet produced by Novomet.

    Installation of the surface units for the sensors can be done both inside and outsidethe VSD. Reception and transmission of data is carried out by means of protocols RS-232or RS-485. Supply voltage for the downhole units is 220 V.

    Operation with SCADA

    The NEMA type drives Triol 01, 02, and 06 can be interfaced to SCADA. Data istransmitted over the RS-485 protocol. Automatic tuning of communication is possible forthe following protocols:

    Triol setting of communication channel for Triol protocol; Region communication channel for Region 2000 protocol; Telescope communication channel for Telescope protocol; Salym Pet communication channel for Salym protocol.

    With the protocol Modbus RTU it is possible to communicate with the dispatchingstation.

    The NEMA type drives Triol 01, 02, and 06 can be provided with custom digitaland analog inputs for connecting various sensors.

  • 7/26/2019 Catalog Po Ak 2015

    37/3836

    S

    Services

    Triol Corporation is a leading developer and manufacturer of electric equipment. Thatswhy it pays considerable attention to service support of the products oered. We conducttrainings for maintenance personnel of our Customers and Partners.

    Triol Corporations service support is carried out in collaboration with our Partners andincludes:

    Warranty repair and spare parts; Post-warranty repair and spare parts; Diagnosis and Troubleshooting; Online Technical support ; Site inspection; Preventative service;

    Personnel trainings.

    We have spare parts warehouse and service support through our partners. It allows usto immediately respond to your requests and allows our Partners and Customers to feelcondent in the future.

  • 7/26/2019 Catalog Po Ak 2015

    38/38

    S

    Supporting documentation

    Supporting documents include: Registration certicate. It includes main information, technical details of the product,

    information about resources, lifetime and storage periods, manufacturer warranty;data about the delivery set; packing and reception certicates; product service record,notes on maintenance and storage; details about utilization and reclamation; specialnotes;

    Operation manual contains information about the installation, operation and tech-nical parameters of variable speed drive Triol AK.

    We can oer you a specialized Service software for getting, archiving and handling datafrom the well. It allows to analyze the event log on more than 50 indicators of the wellbehavior. The information is available both in graphic form and in Excel charts for dataexchange convenience. Combination of service software and Triol MT01 allows imple-

    menting wells supervision.You can download up to date manuals and service software on our website

    www.triolcorp.com in sections Technical documents and Software.