Upload
itmikepitro
View
469
Download
2
Tags:
Embed Size (px)
Citation preview
AIR CONDITIONERS LINEUP
The Intelligent Choice in Comfort
SPLIT / MULTI SPLIT / VRF / VENTILATION / AIR TO WATER
002
Creation of ComfortFujitsu General creates high-quality and
environmentally-friendly products that provide good comfort in accordance
with our basic policy to a create comfortable environment
by utilizing the air conditioning technology and creativity
we have fostered over many years.
FUJITSU GENERAL AMERICA, INC.
FUJITSU GENERAL DO BRASIL LTDA.
FUJITSU GENERAL (ASIA) PTE. LTD.
FUJITSU GENERAL (THAILAND) CO., LTD. FUJITSU GENERAL ENGINEERING (THAILAND) CO., LTD. FGA (THAILAND) CO., LTD. TCFG COMPRESSOR (THAILAND) CO., LTD.
FUJITSU GENERAL LIMITED
F.G.L.S ELECTRIC CO., LTD.
FUJITSU GENERAL ORIENT INTERNATIONAL ELECTRONICS SALES(SHANGHAI)CO., LTD
FUJITSU GENERAL (SHANGHAI)CO., LTD
FUJITSU GENERAL CENTRAL AIR-CONDITIONER (WUXI) CO., LTD.
FUJITSU GENERAL (EURO) GmbH
FUJITSU GENERAL (U.K.) CO., LIMITED FG EUROFRED LIMITED WAVE AIR CONDITIONING LIMITED
FUJITSU GENERAL (TAIWAN) CO., LTD.
FUJITSU GENERAL NEW ZEALAND LIMITED
FUJITSU GENERAL (AUST.) PTY LIMITED
FUJITSU GENERAL (MIDDLE EAST) FZE
003
Sales Companies Head Office
Manufacturing Companies
FGA (Thailand) Co., Ltd.Fujitsu General Central Air-conditioner (Wuxi) Co., Ltd. Fujitsu General (Thailand) Co., Ltd.Fujitsu General Engineering (Thailand) Co., Ltd.TCFG Compressor (Thailand) Co.,Ltd.
Fujitsu General (Shanghai) Co., Ltd. F.G.L.S. Electric Co., Ltd.JAPAN Head OfficeR&D Center And 60 m Height Difference Testing Tower
High Quality Development & Production Environment
12 Overseas Sales Companies and 7 Overseas Manufacturing Companies
004
COOCORRPORRRRRAAATATE HIISTTSTORORORORORRYYY
Since 1936
*1. Announced 1991. In room air conditioner for the home (our companys investigation)*2. Announced 1994. In room air conditioner for the home (our companys investigation)*3. Announced 2002. In room air conditioner for the home (our companys investigation)
Powerdiffuser
*1 *2 *3
TM
1976:North America sales company.
1977:Europe sales company (UK).
1978:Australia sales companyEurope sales company (Germany).
1980:Brazil sales company
1991:Air conditioner manufacturing company in Thailand.
2001:VRF air conditioners
2003:Air conditioner with the worlds first automatic self-cleaning filter system
1994:Air conditioner manufacturing company in Shanghai, China.
1997:Asia sales company (Singapore).
1936:Established as Yaou Shouten Ltd.
1960:Air conditioning business start. Japan-domestic business start.
1971:Air conditioner exports to Middle East.
1977:"Super Power, Super Quiet" series
1982:Window type 3 Super series
1985:Large wall mounted and multi air conditioner introduced.
1991:Air conditioner with the worlds first lambda heat exchanger
1995:Air conditioner with the worlds first power diffuser
Overseas Air Conditioning Business since 1971
Company Establishment
Sales Company Establishment
Manufacturing Company Establishment
1936 1980 1990 2000
005
2009:VRF combination type
Air to Water system
2011:Hi-spec Design model
Small VRF series
1998:Air conditioner motor manufacturing company in Thailand.
1998:Middle East sales company (UAE) New Zealand sales company
2002:Taiwan sales company
2006:China sales company
2006:VRF air conditioner manufacturer, sale, and service company in China.
2007:Air conditioner technology building completed on Main Office group.
2012:VRF Heat Recovery type
2014:Small VRF series
20102005 2011 2012 2014
2009:Operation of compressor factory begins in Thailand.
2012:Joint venture with Toshiba Carrier Corporation.
006
Advanced Research Facility and Equipment
Testing Laboratory
HIIH GGGH QUAUUAUAAALIL TY DDEVEVVVVE EELELELELE OPMENT && PP PRORODUD CTCTIOIONN FAACILIL TITIIIESESS
Air flow testing
Calorimeter testingSound testing
Severe environmental testing
Water shower testing
Vibration testingCompressibility
testing
Performance Testing
Transportation & Handling
Reliability Testing
Fujitsu General EMC Laboratory Limited
60-m Hight Difference Testing Tower
Objective is to confirm oil circulation of compressor for reliability
R & D Center
International test site for EMC regulation
007
Acquisition of
ISO 9001and ISO 14001 Each of overseas production bases (5 companies) has completed the acquisition of ISO 9001 and ISO 14001 individually.
In 2012, overseas sales bases (11 companies) acquired the certification of ISO 14001.
Receiving inspectionParts procurement requires a suppliers test report. European regulation RoHS inspection is also performed by special test department in-house. Total number inspection is performed especially on main parts to remove defectives.
Stringent product quality inspection
Stringent quality inspection is carried out at all production processes. High quality is maintained by stringent checks by inspectors and repetitive inspection.
All Fujitsu General factories have acquired ISO 9001, and have built a quality control system common around the world. High quality products are offered to all over the world based on stringent quality inspections.
HIIGHGH Q QUAUALILITYTY AASSSSURANCE
High Quality AssuranceProduct quality assurance
Parts & Material
Assembly
Packing
Shipping
Product quality inspections
Assembly visual inspection
Sampling inspection Visual inspection Water injection inspection Vibration drop test
Heat run inspection
Completed product visual inspection
Abnormal sound inspection
Pressure resistance inspection
Primary leak inspection
Secondary leak inspection
Performance inspection
Insulation resistance inspection
Withstand voltage inspection
Insulation resistance inspection Withstand voltage inspection
RoHS inspection Parts visual inspection Parts specifications inspection
Balancer inspection
ISO9001 ISO14001 ( ) Number of companies
Europe Sales subsidiary (3)
Japan Head office Manufacturing subsidiary (2)
Oceania Sales subsidiary (2)
Middle East Sales subsidiary (1)
North America Sales subsidiary (1)
Receiving inspections
Completed product inspection
South America Sales subsidiary (1)
Asia Sales subsidiary (3) Manufacturing subsidiary (5)
008
GLOBAL BUSINESS ACTIVITIES
Billboard at airport
We are engaging in advertising, human resource development, CS activities, and social contribution activities worldwide. These activities have been recognized throughout different regions by the awards we have been honored with.
Billboard (Montreal)
Training (Brazil)
Distributor meeting HVAC trade show in Brasil (FEBRAVA)
Call center Distributor meeting (Dubai)
Training for dealers (Middle East)
Gold Award (Category: HVAC & PLUMBING) in Readers Choice Awards
Dealer Design Awardsof the NEWS
AsiaAAMiddle EastasttleMiddlele EEaEaastadMMiddMMMM
Middle East
Europe
eeaanniiaanaOce
AAmmericcaaa
America
009
China State ConstructionEngineering Luban Prize
Billboard (Hong Kong) Distributor meeting
Presentation for sales companies (Myanmar)
SE training
Training for installer Billboard (Tianjin)
Presentation & training HVAC trade show in Europe countries
HVAC trade show in Europe countries
HVAC trade show in Australia
The product design competition has existed since 1955. Its award, the red dot, is an internationally recognised quality seal.
The iF Product Design Award is given each year by iF International Forum Design GmbH for industrial products from around the world.
The Good Design Award is sponsored by the Japan Institute of Design Promotion and is awarded once a year for an item of excellent design.
GfK retail No.1 products in 5 years
Factory tour for primary schoolCharity (Christchurch)
Canstar Blue Most SatisfiedCustomers Award
Coolworld Industry Awards"Most Efficient Air Conditioner"
Asia
Europe
Oceania
International authoritative design awards
010
CORE TECHNOLOGY
Optimized Inverter Control
Pursuit of Seasonal Efficiency
IPM*: Intelligent Power Module
In addition, the voltage is raised at the start of operation and fast comfort is attainable by more powerful operation.
Temp.
SettingTemp.
Time
I-PAM Inverter
Conventional Inverter
Over 90% of actual operation time, air conditioners are operated at partial capacity instead of rated capacity. We focused on high seasonal efficiency by all DC inverter control and high efficiency technology.
I-PAM (IPM*+PAM) inverter controlI-PAM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform. This promotes the effective use of the input power supply to attain high performance.
V-PAM (Vector + I-PAM) inverter controlV-PAM inverter control reduces the effects of magnetic flux and increases the maximum speed and efficiency of the compressor by vector control technology. With this technology, further miniaturization, higher efficiency, and better performance are attained.
High Efficiency
HighHigh
CO
PC
OP
(%)(%)Heating part loadHeating part load
2525 5050 7575 100100
Frequent operation range
Conventionalinverter control
I-PAM inverter control
More compact than conventional models Vector I-PAM
It becomes more powerful with the newly developed high efficient compressor motor control.
011
All DC Inverter Technology
High Efficiency Heat Exchanger
DC twin rotary compressorThe high efficiency DC inverter type "2-cylinder rotary compressor" is used for our product ranges. It has achieved higher energy efficiency compared with similar compressors by optimizing the structure inside the compressor.
DC fan motorDC fan motor produces high power, wide operation range, and high efficiency.
Sine-wave DC inverter controlHigh efficiency operation is realized by using a sine wave DC inverter control.
High density multi-path heat exchangerHeat exchange performance is substantially improved by thin and high-density heat exchanger and multi-path efficiency technology.
High performance sub-cool heat exchangerHigher performance achieved by mounting of counter type bypass circuit. (Large multi type, VRF)
Compressor capacity
Com
pres
sor e
ffici
ency
Min. Max.
High Wide high efficiency range !
High efficiency impactson seasonal efficiency
5 mm
20 mm
Refrigerant
Multi-path (image)
Multi-path heat exchanger
Lambda heat exchanger
Sub-coolerHeatexchanger
In case of cooling circuit
Indoor unitOutdoor unit
Compressor
Heat exchanger
Wide high efficiency rangeDC twin rotary compressor
CORE TECHNOLOGY
012
Economy operationLimits the maximum operation current, and the power consumption is cut down and the maximum load is suppressed.
+2C *Max. 30CCooling / Dry
Heating
-4C *Max. 16C
Saving operation
Set temp.
Set temp.
Human sensor
SAVE !AUTO
RESTART
Normal operation Normal operation
Judgment(Over 20 min.)
Human sensor coverage
90 100
6 m 6 m
Energy Saving Control
Smart Operation
Time
Economy operation
Normal operationSetting
temperature
Human sensor control Human sensor catches movements of people in a room, and operates with lower capacity when people leave the room. When people come back to the room, it automatically returns to the previous operating mode.
013
Room temperature set point limitationThe minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants.
Auto-off timer The indoor unit is turned off
automatically when it reaches to the preset operating time frame.
The time frame of the "Auto off timer" can be flexibly scheduled.
Off time can be set from 30 to 240 minutes.Normal Time
ON
8 17 24
Over Time
ONOFF Auto OFF
Set interval time (17:0024:00)
1 hour 1 hour
ON Auto OFF
Example: At interval time hour (17:0024:00) to prevent forgetting to turn off Set off time : 1 hour
Set temperature auto return The setting temperature automatically
returns to the previous setting temperature.
The time range in which the set temperature can be changed is 10 to 120 minutes.
Capacity save operationOperation capacity can be set in 5 steps for rated capability. The power consumption at peak is cut down and the maximum load is suppressed.
Time
Capacity
Settinglevel
Capacity saveSettingrange
100%
80%
60%
40%
0%
Setting temp.
Coolingoperation
24C22C
Set temperature change Auto return
Time
Settable time range10 to 120 minutes
Setting temp.
Heatingoperation
25C
23C
Set temperature change Auto return
11:40 13:40 Time
Settable time range10 to 120 minutes
Normal set temp. range Limit set temp. range
30C
10
CORE TECHNOLOGY
014
Hea
ting
capa
city
(kW
)
Ambient temperature (C)
High
-7 High
Keeping rated capacity
Comfort Performance
High heating capacity is realized even at low outdoor temperature by mounting a large heat exchanger or large DC rotary compressor and developing high performance inverter PCB
Powerful Heating
All DC inverter technology
By All DC inverter control, electricity loss is decreased and power consumption is substantially reduced.
High efficiencyDC Fan motor
DC Rotary compressor
High density heat exchanger
High-density 5-mm thin tube diameter heat exchanger mounted. Capacity is enlarged including sub heat exchanger. Heat exchange efficiency substantially improved.
5-mm
Making the tube thin:
Heat exchanger volume
About 35% UP! comparing previous model
Sub heat exchanger
015
Quick Comfort
Auto changeover functionAt Auto setting, the cooling / heating mode is automatically switched according to the set temperature and room temperature.
Outdoor unit low noise operationUsers can choose low noise levels, depending on the installation environment. The operation time can be set using the timer.
Comfort airflowPrecision wind direction control is realized and ventilation efficiency is also improved by 3 technologies. Our airflow control makes your environment more comfortable.
10C Heat operationWhen you leave, minimum heating operation is performed to maintain the room temperature. (Maintained at 10C)
Powerful operationContinuous operation by maximum airflow and maximum compressor speed after a certain period of time allows the temperature to reach the setting temp. quickly.
Cooling operationHeating operation
Cooling fan operationHeating fan operation
Set Temp.0.5C
-0.5C
2C
-2CTime
Quiet and Comfort ControlAirconditioningload factor
Capacity
Operatingsound
Time
100%
58 dB
0
0
Heat load
Quiet priority low noise mode
Setting temp.
Normal mode
Time
Tem
pera
ture
Powerful operation mode
(24/30)
33 32 31 30 29 (C)
(24/30)
(C)15 16 17 18
Horizontal airflow
Vertical airflow
10C
20C
10C HEAT Button ON
Indoor unit operation START
CORE TECHNOLOGY
016
Pursuit of advanced design achieving both functionality and beauty.
Smart Design
017
Wall Mounted
High Spec. & Design : ASYG09LTCA / ASYG12LTCA
High COP : ASYG07LUCA / ASYG09LUCA / ASYG12LUCA / ASYG14LUCA
Standard : ASYG07LMCA / ASYG09LMCA / ASYG12LMCA / ASYG14LMCA
Basic : ASYG07LLCC/ASYG09LLCC/ASYG12LLCC
Thinness and simplicity was thoroughly pursued in this design to fit the interior design. The lambda shaped high-density multi-path heat exchanger construction and full cover slide open panel provide both beauty and functionality. The remote controller has also been designed utilizing ergonomics for ease of use while also pursuing beauty even in the details. Fujitsu General provides its customers with highly functional air conditioners designed with high artistic sensitivity
Creating Harmony and New Interior Design Space in a Variety of Installation Environments
Wall Moun
High Spe
High COP
Standard
Basic : AS
g g y
The stylish design of this simple flat panel looks thin and compact from all directions.
018
Residential useEasy-To-Use Control
Indoor unit
Smartphone
Tablet
PCRouter(Field supplied)
Wireless LANInterface(Option)phone
et
Internet
R(
It is the most advanced solution to remotely manage an Air Conditioning system using all sort of mobile devices such as Smartphones, Tablets, and PC.
Fujitsu General provides an interface that supports central management systems such as KNX,MODBUS, BACnet, and LONWORKS.
This allows customers to easily perform central control and monitoring of air conditioning equipment.
Easy air conditioner control from inside or outside the house using the Smartphones, Tablets, and PC
CORE TECHNOLOGY
N E W
019
CentralRemote Controller
Home central control
SimpleRemote Controller
WiredRemote Controller
Simple individual control
Fujitsu General is using ergonomics to expand the use of easy-to-use designs such as easy-to-read large LCD panels, easy-to-operate buttons, and displays with easily recognizable icons.
The individual controllers match the user operational environments, and the home controller makes batch energy saving management easy. Ease of use was pursued using simple operation buttons, a large LCD screen, and other features.
Slim WirelessRemote Controller
Fujitsu General provides various easy-to-use Controllers
020
Large buildingmanagement control
System ControllerWired Remote Controller
Touch Panel
Individual & Simple central control Each floor or Small buildingmanagement control
Software
CCoommmmeerciaall uusseeEasy-To-Use Control
Fujitsu General is using ergonomics to expand the use of easy-to-use designs such as easy-to-read large LCD panels, easy-to-operate buttons, and displays with easily recognizable colors and icons.
We offer a wide range of central control equipment to meet the building air conditioning scope and application. Great care was taken to achieve a visually intuitive design and one-touch operation.
Fujitsu General provides various easy-to-use Controllers
Touch Panel Controller
N E W
CORE TECHNOLOGY
021
It is the most advanced solution to remotely manage an Air Conditioning system using all sort of mobile devices such as Smartphones, Tablets, and PC.
Fujitsu General provides an interface that supports central management systems such as KNX, MODBUS, BACnet,and LONWORKS.
This allows customers to easily perform central control and monitoring of air conditioning equipment.
Easy air conditioner control in the office using the Smartphones, Tablets, and PC
Smartphone
Tablet
PC
SmarInternetIndoor unit
Router(Field supplied)
Wireless LANInterface(Option)
022
Fujitsu General provides a variety of product and technical information to engineers and consultants, and also conducts new product research and design support activities. We provide a wide range of support to maintain high quality from design to installation.
AIRSTAGETM SUPPORT
Product information New product information is provided in the form of documents and movies for every new model released. These can be downloaded from a private section of our website. To access this website, please contact your Fujitsu representative.
Features
Product News
Brochures & All Manuals
Feature Promotion Movie
Technical information We provide information and tools that are useful for air conditioning system design, such as unit performance data and tools that make model selection and estimation easy.
Features
Design & Technical Manual
Model Selection & Estimation
Certificate Data
2D / 3D CAD Data
023
Training for installerPresentation & training for dealers 2
52.00
0
47.75
0
43.50
0
39.25
0
35.00
0
Technical support Technical support is provided at every stage from design to installation to assist in providing the most suitable air conditioning solution.
Features
CFD Simulation
Guide line
Commissioning Support
Training Fujitsu General has 7 training facilities around the world that regularly conduct specialized product, technical, and service training. These research facilities also support the development of people with high technical capability.
Features
Designing AIRSTAGETM Systems
Control System on-site training
DESIGN SUPPORT TOOL
024
Information on the latest history update is demanded.
Information on the latest history update replied.
User side(PC) FTP server side (PC)
Automatically create model selection information Each unit can be automatically set by entering the required
performance, type, and temperature conditions for each indoor unit and then dragging and dropping into the outdoor unit.
Piping and wiring diagrams can be created automatically and it is easy to set branches, grouping, and options.
The additional refrigerant charging amount is automatically calculated when the pipe length is entered.
It is also easy to set the remote controller groups, central controller and converters.
The equipment list including the equipment information is created automatically.
Output the format that matches the applicationThe information specific to your project can be exported in a number of industry standard file formats.
Word format (rtf)
Excel format (csv)
Auto CAD format (DXF)
2D Data (DXF)
3D Data (RFA)
Update your Design SimulatorDatabase can be easily updated online using AutoUpdate function through FTP.
Put the charts and pens away and design your projects on your computer with ease using the Design Simulator. Everything from selecting indoor and outdoor units, allocating controls and optional parts to designing the piping and wiring systems is made easier using the program's built-in features. Once your project is designed take advantage of the Export functions to easily get materials lists, product specifications, refrigerant calculations and more - it'll even export to Word or Excel formats, and group the relevant CAD data for your project.
Design Simulator
025
3D and 2D product dataWe provide 3D data that closely resemble the actual product appearance. 2D CAD design operations are supported and 2D display is also provided. The data can also be output in other formats, such as DXF and DWG, which are used by other design CAD.
Installation limitationThe equipment installation limitation range is shown. Installation requirements, such as distance from the wall, is automatically displayed to make it easy to produce highly reliable layout designs.
Installation informationOther information, such as symbols showing the airflow direction that are required for installation drawings, is built in and can be automatically reflected in 2D drawings. Installation drawings can be created easily.
Product specifications & link informationContains the basic information required for air conditioner design, including unit size, capacity, input power, noise, and airflow rate. These data can be procured from the Fujitsu General Website, Design Simulator, and Autodesk Seek Website.
Building Information Modeling (BIM)
FUJITSU GENENRAL provides the Building Information Modeling (BIM) object models and contents for our VRF system and some products to the architect, designer and contractor using Autodesk
Revit technology from our Website and Autodesk
Seek Website, etc.
SERVICE AND MAINTENANCE
026
System number001: Controller002: Indoor unit Error code
Unit number
Design for easy maintenanceThe air conditioner operating status and trouble status of the detailed are displayed at the 7-segment of the outdoor unit PCB or on the remote controller screen. The unit status can be checked rapidly and quick response is also possible.
Operation mode status
Discharge temperature / Pressure status
Compressor operation indication
Address / Type / Number of outdoor unit
Error code
Mobile trouble shooting tool for iPhoneWe will release an App of troubleshooting tool for iPhone, iPod touch and other Apple products.
This application is a troubleshooting tool for FUJITSU GENERAL air conditioner (RAC / PAC, VRF)
It helps you to check air conditioner condition.
Error code check, Troubleshooting, and Sensor check are available.
7-segment LED
Wired Remote Controller
Mobile Technician FREE
Wired Remote Controller (Touch panel)Error status / Error history
Fujitsu General aims for the realization of quick service and maintenance.
If trouble should occur in a unit or system, abundant support tools such as trouble code display at the product, Service Tool that allows checking of the detailed status of the entire system, and remote monitoring tool that uses the internet, etc. support quick service and maintenance anywhere and at any time.
027
Error diagnosis by Service Tool The unit status details from single split models to VRF system can be checked on PC screen by connecting Service Tool. Quick countermeasures can be taken
Operation status / control
Monitoring opearting condition
Monitoring sensor data
Indication of trend graph
Error history
Indication of refrigerant circuit diagram (for VRF)
Remote monitoringVRF system operating status and trouble status details can be constantly and remotely monitored over the Internet, etc. Rapid cooperation with the service personnel are also possible.
(Field supplied)
(Field supplied)
Refrigerant piping
Tran
smis
sion
line
Indoor unit
Indoor unitUSB adaptor
(Field supplied)
UTY-ASSX(Communication box and Software)
Internetor
Public TelephoneLine
Service Monitoring Tool
Service ToolUTY-ASGX
Web Monitoring ToolUTY-AMGX
M it i
RemoteMonitoring
Software
Software
APPROACH TO NEW ENERGY EFFICIENCY STANDARD
028
Pursuit of Energy Saving Taking Actual Operation into ConsiderationThe heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated value and the annual operating hours per outdoor temperatures was not taken into consideration.
For this reason, SEER and SCOP* have been made the standard in terms of actual operating hours throughout the year.
Fujitsu General provides air conditioners with higher SEER and SCOP.*SEER and SCOP are indexes that express the annual energy efficiency calculated based on the regulations of (EU) 626/2011.
*: SEER = Seasonal Energy Efficiency Ratio SCOP = Seasonal Coefficient Of Performance
Annual operating hours per outdoor temperature
0403025
Outdoor temperature (C)2015
Freq
uenc
y (h
)
35
50100150200250
Cooling
Heating
Freq
uenc
y (h
)
0100200300400500600
70-15 15
ColderAverage
Warmer
20% less Primary Energy Use
Fujitsu General products with high efficiency and therefore low electricity input and low primary energy usage
20% less CO2 Emissions
Fujitsu General products sharply following the F-Gas regulation 842 / 2006 / EC
20% share of Renewable Energy
Fujitsu General promoting air sourced heat pumps as renewable energy source heating systems
Fujitsu General following the EU climate action plan 20/20/20 by 2020
029
* Enforcement on January 1, 2013 Air conditioners below 12 kW
Performance notation based on multiple points calculations that better matches the actual operation
Energy labelling revision Raising of the CLASS A level
Three climate zone for heating (Average zone : mandatory) (Warmer and colder zone are
optional) Seasonal efficiency Sound power level
Gradual ranking regulation up to A+++ (2013 ~ 2019)
2013~: A, B, C, D, E, F, G
2015~: A+, A, B, C, D, E, F
2017~: A++, A+, A, B, C, D, E
2019~: A+++, A++, A+, A, B, C, D
Current Energy Label
AO-AS-
A
Current Energy Labelling Points New Energy Labelling Points
Operatingpower consumption
Seasonal efficiency
SEER SCOP
Integrates part load capacity Optimised for several rating temperatures
Rated efficiency
Full capacity One point temperature condition
EER COP
Operating power consumption Standby power consumption Crank case heater Thermo off
New criteria
Sound pressure level
Annual efficientoperation
Reduce total power consumption
Low noise products
Total power consumption
Sound power level
EER(Cooling mode)
COP(Heating mode)
3.60 < COP
3.60 COP > 3.403.40 COP > 3.203.20 COP > 2.802.80 COP > 2.602.60 COP > 2.402.40 COP
3.20 < EER
3.20 EER > 3.003.00 EER > 2.802.80 EER > 2.602.60 EER > 2.40
2.20 EER2.40 EER > 2.20
SEER(Cooling mode)
SCOP(Heating mode)
SEER 8.506.10 SEER < 8.505.60 SEER < 6.105.10 SEER < 5.604.60 SEER < 5.10
3.60 SEER < 4.103.10 SEER < 3.602.60 SEER < 3.10
SCOP < 1.90SEER < 2.60
4.10 SEER < 4.60
SCOP 5.104.60 SCOP < 5.104.00 SCOP < 4.603.40 SCOP < 4.003.10 SCOP < 3.40
2.50 SCOP < 2.802.20 SCOP < 2.501.90 SCOP < 2.20
2.80 SCOP < 3.10
Energy Efficiency ClassificationsNew Energy Labelling Requirement 626 / 2011 / EU : Our models have reached the "Class A" ranking, the highest energy efficiency level that is now shown on energy labels in Europe.
New Energy Label *
030
2014 FUJITSU GENERAL SOLUTIONS
Small VRF system
Features Small and light weight design High seasonal energy efficiency Effective air intake grill design Adopting high performance twin rotary compressor Lineup from 4HP to 6HP
N E W
Wired Remote Controller
Features Various timer (ON/OFF/Weekly) Easy one touch operation Automatic address setting Error code and error history display
N E W
Outdoor Air Unit
Features 100% outdoor air intake possible Compact size and high static pressure 200 Pa (22.4 kW) High energy saving by adopting DC motor
N E W
DX-Kit for air handling applications
Features Possible to connect the air handling unit and the fan coil unit Optimial control with multiple temperature sensors Support a wide range of capacity classes (from 5 kW to 50 kW) Connectable to AIRSTAGETM (J-IIS, J-II, V-II, VR-II) series
N E W
14 kW 22.4 kW 28 kW
EEV unit Control unit
Page110~New VRF systems
Future Release
031
New Air to Water systems
5-kW Monobloc series
Features 55C hot water supply even at -20C outdoor temperature Heating and DHW in one system**Optional parts are required.
N E W Future Release
Control box
032
CONTENTS
033
OPTIONAL PARTSfor VRF 170
VENTILATION 162
SPLIT
MULTI SPLIT
OPTIONAL PARTSfor SPLIT & MULTI SPLIT
V R F
AIR TO WATER
038
068
100
176
092
002
004
006
007
008
010
022
024
026
028
030
034
190
Creation of Comfort
Corporate History
High Quality Development & Production Facilities
High Quality Assurance
Global Business Activities
Core Technology
AIRSTAGETM Support
Design Support Tool
Service and Maintenance
Approach to New Energy Efficiency Standard
2014 Fujitsu General Solutions
All Type Lineup
Feature Explanation
034
ALL TYPE LINEUP SPLIT & MULTI SPLIT
N E W N E W
SPLIT
AOYG18LAC2
AOYG18LAT3
AOYG14LAC2
MULTI SPLIT
WallMountedPage 40 ~
Up to 2 UnitsPage 72
Up to 3 UnitsPage 72
Up to 4 UnitsPage 72
Simultaneous MultiTwin / TriplePage 90
FloorPage 50
Compact Cassette /CassettePage 52 ~
Floor/CeilingPage 56
CeilingPage 58
Slim DuctPage 60
MediumStatic Pressure DuctPage 62
HighStatic Pressure DuctPage 64 ~
Up to 8 UnitsPage 74
ASYG12LMCA ASYG14LMCAASYG09LMCA
ASYG12LLCCASYG09LLCC
N E W
ASYG07LLCC
ASYG07LMCA ASYG18LFCA
AGYG09LVCA AGYG12LVCA
AUYG12LVLB AUYG14LVLB AUYG18LVLB
AGYG14LVCA
ABYG18LVTB
ARYG18LLTBARYG14LLTBARYG12LLTB
High Spec. & Design
High COP
Standard
Basic
5.318
4.114
3.512
2.69
2.07
Capacity (kW)Model Code
ASYG09LTCA ASYG12LTCA
ASYG12LUCAASYG09LUCA ASYG14LUCAASYG07LUCA
035
AOYG24LAT3
AOYG30LAT4
AOYG36LATT
[3phase]
AOYG45LATT
[3phase]
AOYG54LATT
[3phase]
AOYG45LBT8
AUYG24LVLA
ABYG24LVTA
AUYG30LRLE
ABYG30LRTE
ASYG24LFCC ASYG30LFCA
25.090
20.072
15.060
14.054
12.545
10.636
8.830
7.124
ARYG30LMLEARYG24LMLA
ARYG45LHTAARYG45LHTA [3phase]
ARYG54LHTAARYG54LHTA [3phase] ARYG60LHTA [3phase] ARYC72LHTA [3phase] ARYC90LHTA [3phase]
ABYG54LRTA [3phase]
ARYG36LMLEARYG36LMLA [3phase]
ARYG45LMLAARYG45LMLA [3phase]
ABYG36LRTEABYG36LRTA [3phase]
ABYG45LRTAABYG45LRTA [3phase]
AUYG36LRLEAUYG36LRLA [3phase]
AUYG45LRLAAUYG45LRLA [3phase]
AUYG54LRLAAUYG54LRLA [3phase]
036
ALL TYPE LINEUP VRF & VENTILATION, AIR TO WATER
Space savingPage 118 ~
V R F22.4
828.010
33.512
40.014
45.016
50.418
55.920
61.522
Capacity (kW) 15.1-15.56
14.05
12.14HP
AJYA54LALHAJYA45LALHAJYA40LALH
AJY054LCLAHAJY045LCLAHAJY040LCLAH
J-II seriesHeat PumpPage 114 ~
All Models
Set Model AJYA72LALH AJYA90LALH AJY108LALH AJY126LALH AJY144LALH
AJY144LALHH
AJY162LALH AJY180LALH AJY198LALH
Set Model
V-II
serie
s H
eat P
ump
Space savingPage 126 ~
EnergyefficiencyPage 126 ~
Energy RecoveryVentilatorPage 164
Outdoor Air UnitPage 166
Set Model
Set ModelVR
-II s
erie
s H
eat R
ecov
ery
AJY198LALHH
AJYA72GALH AJYA90GALH AJY108GALH AJY126GALH AJY144GALH
AJY144GALHH
AJY162GALH AJY180GALH AJY198GALH
AJY198GALHH
AIR TO WATER
Capacity (kW)
Hydraulic Unit / Outdoor Unit
Hydraulic Unit / Outdoor Unit
Comfort seriesPage 178
Compact modelPage 180
Hydraulic Unit / Outdoor Unit
Airflow rate (m3/h)
Split
Hydraulic Unit / Outdoor Unit
High Power seriesSingle phasePage 179
Hydraulic Unit / Outdoor Unit
Comfort seriesPage 179
Hydraulic Unit / Outdoor Unit
3 phasePage 179
High Power seriesSingle phasePage 178
3 phasePage 178
Split
DH
W in
tegr
ated
Mon
oblo
c
UTZ-BD025B UTZ-BD035B
VENTILATION
Energy efficiencyPage 118 ~
J-IIS seriesHeat PumpPage 110 ~
N E W
N E W N E W N E W
250 350
UTZ-BD050B
500
UTZ-BD080B
800
UTZ-BD100B
1000 1500 2000
ARXH054GTAH
ARXH072GTAH
ARXH096GTAH
037
67.024
85.030
90.032
73.526
78.528
95.034
100.536
107.038
112.040
118.542
123.544
130.046
135.048
AJY216LALH AJY234LALH AJY252LALH AJY270LALH AJY288LALH AJY306LALH AJY324LALH AJY342LALH AJY360LALH AJY378LALH AJY396LALH AJY414LALH AJY432LALH
AJY216LALHH AJY234LALHHAJY252LALHHAJY270LALHHAJY288LALHHAJY306LALHHAJY324LALHH AJY360LALHH AJY378LALHHAJY396LALHH
AJY216GALH AJY234GALH AJY252GALH AJY270GALH AJY288GALH AJY306GALH AJY324GALH AJY342GALH AJY360GALH AJY378GALH AJY396GALH AJY414GALH AJY432GALH
AJY342GALHHAJY216GALHH AJY234GALHHAJY252GALHHAJY270GALHHAJY288GALHHAJY306GALHHAJY324GALHH AJY360GALHHAJY378GALHHAJY396GALHH
11 14 166 85
WSYK160DC9 / WOYK112LCT WSYK160DC9 / WOYK140LCT WSYK160DC9 / WOYK160LCT
WSYG140DC6 / WOYG112LCT WSYG140DC6 / WOYG140LCT
10
WPYA100LE
WSYA100DD6 / WOYA100LDTWSYA100DD6 / WOYA080LDCWSYA100DD6 / WOYA060LDCWSYA050DD6 / WOYA060LDC
WGYK160DD9 / WOYK112LCT WGYK160DD9 / WOYK140LCT WGYK160DD9 / WOYK160LCT
WGYG140DD6 / WOYG112LCT
All Models
WGYG140DD6 / WOYG140LCT
WGYA050DD6 / WOYA060LDC WGYA100DD6 / WOYA100LDTWGYA100DD6 / WOYA080LDCWGYA100DD6 / WOYA060LDC
N E W
Future Release
038
039
An air conditioner that is people-friendly is also environment-friendly. Fujitsu General offers a broad lineup of products from large living rooms to bedrooms and childrens rooms. We make your room more comfortable with a wide range of air conditioner types from ceiling wall type with automatic filters and cleaning functions to wall mounted type that improve the air cleaning function. Of course these models feature highly efficient operation that conserves electricity.
Energy saving design to provide a comfortable indoor environment while being environment-friendly.
Wall Mounted
Floor
Compact Cassette
Cassette
Floor/Ceiling
Ceiling
Slim Duct
Medium Static Pressure Duct
High Static Pressure Duct
SPLIT
9 types 54 models
040050052054056058060062064
040
Low noise mode for outdoor unitLow noise mode of outdoor unit can be selected by wireless remote controller.
Thin & Slim designThin and slim design is realized by high density multi-path heat exchanger and high efficiency wind blower.
Powerful heatingRated heating capacity is maintained up to an outdoor temperature lower than -7 C. This new model can operate even at -20 C low outdoor temperature.
Powerful operation mode20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly.
Energy saving controlHuman sensor catches movements of people in a room, and operates with lower capacity when people leave the room. When people come back to the room, it automatically returns to previous operating mode.
Low ambient operation
3 Mode timer (Weekly/Program/Sleep)Weekly timer can be easily set by wireless remote controller. ON, OFF can be set up to 4 times in 1 day and up to 28 times in 1 week. For other modes, program timer and sleep timer can be also selected by one push.
Optional parts
Wired Remote Controller:
Simple Remote Controller:
Communication kit:
UTY-RNNYM / UTY-RVNYM
UTY-RSNYM
UTY-TWBXF
Wireless R.C. For ASYG09LTCA For ASYG12LTCA
Noi
se
Noise level Max. power operating
POWERFULPOWERFULPOWERFUL
10C HEAT OperationThe room temperature can be set to go no lower than 10C, thus ensuring that the room does not get too cold when not occupied.*Only available with Wireless RC.
Low noisemode
High Spec. & Design : ASYG09LTCA / ASYG12LTCA
Wall Mounted
Features
Large fan
Open panel
Large intake
40302010
0-10-20 -20C
Cooling
24CHeating
43C
-10C
3 dBDown
90 100
6m 6m
-25 1050-5-10-15-20
1.0
2.0
3.0
4.0 New model
Current model
New model
Current model
-25 1050-5-7-7 -10-15-20
1.0
2.0
3.0
4.02.5-kW class 3.5-kW class
Hea
ting
Cap
acity
(kW
)
Hea
ting
Cap
acity
(kW
)
Outdoor Temperature (C) Outdoor Temperature (C)
041
Dimensions Models: ASYG09LTCA / ASYG12LTCA
282
870 185
337
55
100
or m
ore
(Unit : mm)
Capacity
EERCOP
Running Current
Energy EfficiencyClass
Moisture Removal
Airflow Rate (High)
Sound Pressure (Cooling)Sound Power (Cooling)
Net Dimension H x W x D
Piping Connections (Small / Large)
Max Height Difference
Operation RangeCoolingHeating
Drain hose Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
Annual Energy Consumption
Refrigerant (Global Warming Potential)
HeatingInput Power
Power SourceCooling
Cooling
Indoor / Outdoor
H/M/L/Q High
Heating
Cooling/Heating
Indoor
Outdoor
CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
A
W/W
m3/h
I/h
dB(A)
kWh/a
mm
V/ /Hz
kW
Specifications
Model No.Indoor unit
Outdoor unit
ASYG12LT CA
AOYG12LTC230/1/50
3.5 (1.1-4.0)4.0 (0.9-6.5)0.850/0.910
4.124.40
4.0/4.3
1.843/37/32/21
48
850/2,050282870185
9.5 (21)620790290
40 (88)6.35/9.52
13.8/15.8 to 16.720 (15)
15-10 to 43-20 to 24
R410A (1,975)
ASYG09LTCA
AOYG09LTC230/1/50
2.5 (0.9-3.5)3.2 (0.9-5.4)0.505/0.660
4.954.85
CoolingHeating (Average) W/W
CoolingHeating
CoolingHeating (Average)
8.504.60A+++A++
8.504.60A+++A++
2.5/3.0 3.5/4.0
2.6/3.3
1.342/36/32/21
48
103912
1441217
800/1,700282870185
9.5 (21)540790290
33 (73)6.35/9.52
13.8/15.8 to 16.720 (15)
15-10 to 43-20 to 24
R410A (1,975)
5963
6064
SEERPdesign
SCOP
Cooling/Heating
kWCooling/Heating (@-10C)
IndoorOutdoor
High High
IndoorOutdoor
042
Thin & Slim designThin and slim design is realized by 5-mm heat exchanger and high efficiency wind blower.
Powerful operation20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly.
Optional parts
Wired Remote Controller:
Simple Remote Controller:
Communication kit:
UTY-RNNYM, UTY-RVNYM
UTY-RSNYM
UTY-TWBXF
Wireless R.C. For ASYG07/09LUCA For ASYG12/14LUCA
High COP : ASYG07LUCA / ASYG09LUCA / ASYG12LUCA / ASYG14LUCA
Wall Mounted
Features
Big open panel and High density multi path heat exchanger
5 mm
20 mmH282 X W870 X D185 Large fan
Openpanel
Distributor 4-path
RefrigerantLarge intake
185 mm
Low ambient operation
3 Mode timer (Weekly/Program/Sleep)Weekly timer can be easily set by wireless remote controller. ON, OFF can be set up to 4 times in 1 day and up to 28 times in 1 week. For other modes, program timer and sleep timer can be also selected by one push.
40
30
20
10
0
-10
-20 -15C
Cooling
24CHeating
43C (12/14)46C (7/9)
-10C
Low noise mode for outdoor unitLow noise mode of outdoor unit can be selected by wireless remote controller. N
oise
Noise level Max. power operating
10C HEAT OperationThe room temperature can be set to go no lower than 10C, thus ensuring that the room does not get too cold when not occupied.*Only available with Wireless RC.
Low noisemode
3 dBDown
043
Dimensions Models : ASYG07LUCA / ASYG09LUCA / ASYG12LUCA / ASYG14LUCA (Unit : mm)
Capacity
EERCOP
SEERPdesign
SCOP
Running CurrentAnnual Energy Consumption
Energy Efficiency Class
Moisture Removal Sound Pressure(Cooling)Sound Power (Cooling) Airflow Rate (High)
Net Dimension H x W x D
Drain Hose Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Max Height Difference
CoolingHeating
Piping Connections (Small / Large)
Operation Range
Refrigerant (Global Warming Potential)
HeatingCooling/HeatingInput Power
Power SourceCooling
Cooling
Indoor H/M/L/QOutdoor
Indoor
Outdoor
HighHighHigh
IndoorOutdoor
Heating
Cooling
Cooling
CoolingHeating
Cooling/Heating
Indoor / Outdoor
CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
W/W
W/W
kW
m3/h
I/h
A
kWh/a
dB(A)
mm
V/ /Hz
kW
Specifications
Model No.Indoor unit
Outdoor unit
ASYG09LUCA
AOYG09LUCB230/1/50
2.5 (0.5-3.2)3.2 (0.5-4.2)0.555/0.680
4.504.71
2.5/2.87.104.10A++A+
3.1/3.41239561.3
42/36/32/21485960
800/1,720282x870x185
9.5 (21)540x660x290
25 (55)6.35/9.52
13.8/15.8 to 16.720 (15)
15-10 to 46-15 to 24
R410A (1,975)
ASYG12LUCA
AOYG12LUC230/1/50
3.5 (0.9-4.0)4.0 (0.9-5.6)0.905/0.930
3.874.30
3.5/3.97.054.00A++A+
4.6/4.7174
13631.8
43/37/32/21506065
850/1,940282x870x185
9.5 (21)540x790x290
33 (73)6.35/9.52
13.8/15.8 to 16.720 (15)
15-10 to 43-15 to 24
R410A (1,975)
ASYG14LUCA
AOYG14LUC230/1/50
4.2 (0.9-5.0)5.4 (0.9-6.0)1.235/1.380
3.403.91
4.2/4.86.784.00A++A+
5.8/6.3217
16772.1
45/40/33/25506065
900/1,940282x870x185
9.5 (21)540x790x290
34 (75)6.35/12.7
13.8/15.8 to 16.720 (15)
15-10 to 43-15 to 24
R410A (1,975)
ASYG07LUCA
AOYG07LUCA230/1/50
2.0 (0.5-3.0)3.0 (0.5-4.0)0.460/0.660
4.354.55
2.0/2.67.204.10A++A+
2.6/3.497
8871.0
38/35/31/21465758
680/1,720282870185
9.5 (21)540660290
23 (51)6.35/9.52
13.8/15.8 to 16.720 (15)
15-10 to 46-15 to 24
R410A (1,975)
282
870 185
337
55
100
or m
ore
Heating (Average)
Heating (Average)
Cooling/Heating (@-10C)
044
High efficient compact design More comfort airflow
Powerful operation20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly.
24 hr Programmable timer 24 hr program timer and sleep timer can be easily set.
Low noise mode for outdoor unitLow noise mode of outdoor unit can be selected by wireless remote controller.
10C HEAT OperationThe room temperature can be set to go no lower than 10C, thus ensuring that the room does not get too cold when not occupied
Optional parts
Wired Remote Controller:
Simple Remote Controller:
Communication kit:
UTY-RNNYM, UTY-RVNYM
UTY-RSNYM
UTY-XCBXZ2
Wireless R.C. For ASYG07/09/12LMCA For ASYG14LMCA
Standard : ASYG07LMCA / ASYG09LMCA / ASYG12LMCA / ASYG14LMCA
Wall Mounted
Features
Making the tube thin:
7 mm 5 mm
Even temperature
Improved heatexchanger effectiveness
High density heat exchanger Power diffuserVertical airflow provides powerful floor level heating.
Horizontal airflow dose not blow cool air directly at occupants in the room.
Heating
Cooling
Low ambient operation
40
30
20
10
0
-10
-20 -15C
Cooling
24CHeating43C
-10C
Increase of heat exchangervolume by high density and adopting sub heat exchanger
Noi
se
Noise level Max. power operating
Low noisemode
3 dBDown
045
Dimensions Models : ASYG07LMCA / ASYG09LMCA / ASYG12LMCA / ASYG14LMCA (Unit : mm)
Capacity
EERCOP
SEERPdesign
SCOP
Running CurrentAnnual Energy Consumption
Energy Efficiency Class
Moisture Removal Sound Pressure(Cooling)Sound Power (Cooling) Airflow Rate (High)
Net Dimension H x W x D
Drain Hose Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Max Height Difference
CoolingHeating
Piping Connections (Small / Large)
Operation Range
Refrigerant (Global Warming Potential)
HeatingCooling/HeatingInput Power
Power SourceCooling
Cooling
Indoor H/M/L/QOutdoor
Indoor
Outdoor
HighHighHigh
IndoorOutdoor
Heating
Cooling
Cooling
CoolingHeating
Cooling/Heating
Indoor / Outdoor
CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
W/W
W/W
kW
m3/h
I/h
A
kWh/a
dB(A)
mm
V/ /Hz
kW
Specifications
Model No.Indoor unit
Outdoor unit
ASYG09LMCA
AOYG09LMCA230/1/50
2.5 (0.5-3.2)3.2 (0.5-4.0)
0.65/0.733.854.38
2.5/2.47.004.10A++A+
3.2/3.51258201.3
43/40/32/21455958
750/1670268X840X203
8.5 (19)535X663X293
21 (46)6.35/9.52
13.8/15.8 to 16.720 (15)
15-10 to 43-15 to 24
R410A (1,975)
ASYG12LMCA
AOYG12LMCA230/1/50
3.4 (0.9-3.9)4.0 (0.9-5.3)
0.97/1.023.503.92
3.4/3.57.004.00A++A+
4.6/4.8170
12251.8
43/40/32/21505961
750/1830268X840X203
8.5 (19)535X663X293
26 (57)6.35/9.52
13.8/15.8 to 16.720 (15)
15-10 to 43-15 to 24
R410A (1,975)
ASYG14LMCA
AOYG14LMCA230/1/50
4.0 (0.9-4.4)5.0 (0.9-6.0)1.135/1.365
3.523.66
4.0/3.96.904.00A++A+
5.3/6.3203
13652.1
44/40/33/25496063
750/1800268X840X203
8.5 (19)540X790X290
34 (75)6.35/12.7
13.8/15.8 to 16.720 (15)
15-10 to 43-15 to 24
R410A (1,975)
ASYG07LMCA
AOYG07LMCA230/1/50
2.0 (0.5-3.0)3.0 (0.5-3.4)0.465/0.685
4.304.38
2.0/2.36.804.10A++A+
2.5/3.31037861.0
43/40/32/21455958
750/1670268X840X203
8.5 (19)535X663X293
21 (46)6.35/9.52
13.8/15.8 to 16.720 (15)
15-10 to 43-15 to 24
R410A (1,975)
840 203
268
Heating (Average)
Heating (Average)
Cooling/Heating (@-10C)
046
High efficient compact design
Powerful operation20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly.
Economy operationSetting temp. is shifted by 1C automatically.
ON-OFF Programmable timerYou can set an integrated ON-OFF or OFF-ON timer suitable for your life style. (Setting time: 0.5, 1, 1.5, 2, 2.5, -----9.5, 10, 11, 12 hours)
Super Quiet OperationTop class low noise operation by new airflow construction. Our quiet operation makes the more comfortable environment in a bed room and a study room, etc.
Optional parts
Remote Controller Holder: UTZ-RXLA
Wireless R.C.
Basic : ASYG07LLCC / ASYG09LLCC / ASYG12LLCC
Wall Mounted
Features
Volume reduction of heat
exchanger: 30%
Making the tube thin:
7 mm 5 mm
Even temperature
Improved heatexchanger effectiveness
High density heat exchanger
OFF-ON timer
From sleep to wake up
ON-OFF timer
From wake up to go to work
OFF10hours
ON 7hours
12
6
9 3
PM11:00 set
12
6 ON
9hours
OFF2hours
9PM9:00 set
3
QuietFan speed
22 dB (A)Noise level
Low ambient operation
40
30
20
10
0
-10
-20 -15C
Cooling
24CHeating43C
-10C
Tem
p.
Economy operation
Shift setting temp
Normal operation
Time
Set temperature
(In case of cooling operation)
047
Dimensions Models : ASYG07LLCC / ASYG09LLCC / ASYG12LLCC (Unit : mm)
820 206
262
Capacity
EERCOP
SEERPdesign
SCOP
Running CurrentAnnual Energy Consumption
Energy Efficiency Class
Moisture Removal Sound Pressure(Cooling)Sound Power (Cooling) Airflow Rate (High)
Net Dimension H x W x D
Drain Hose Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Max Height Difference
CoolingHeating
Piping Connections (Small / Large)
Operation Range
Refrigerant (Global Warming Potential)
HeatingCooling/HeatingInput Power
Power SourceCooling
Cooling
Indoor H/M/L/QOutdoor
Indoor
Outdoor
HighHighHigh
IndoorOutdoor
Heating
CoolingHeating (Average)
Heating (Average)
Cooling/Heating (@-10C)
Cooling
CoolingHeating
Cooling/Heating
Indoor / Outdoor
CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
W/W
W/W
kW
m3/h
I/h
A
kWh/a
dB(A)
mm
V/ /Hz
kW
Specifications
Model No.Indoor unit
Outdoor unit
ASYG12LLCC
AOYG12LLCC230/1/50
3.4 (0.9-3.8)4.0 (0.9-5.0)1.080/1.130
3.153.54
3.4/3.26.603.80A++
A5.2/5.4
1801,179
1.843/38/33/22
505965
720/1,830262820206
7.0 (15)535663293
26 (57)6.35/9.52
13.8/15.8 to 16.720 (15)
15-10 to 43-15 to 24
R410A (1,975)
ASYG07LLCC
AOYG07LLCC230/1/50
2.0 (0.9-2.8)2.7 (0.9-3.6)0.470/0.620
4.264.35
2.0/2.26.704.00A++A+
2.6/3.01047701.0
43/38/33/22475961
720/1,670262820206
7.0 (15)535663293
24 (53)6.35/9.52
13.8/15.8 to 16.720 (15)
15-10 to 43-15 to 24
R410A (1,975)
ASYG09LLCC
AOYG09LLCC230/1/50
2.5 (0.9-3.0)3.0 (0.9-3.8)0.730/0.740
3.424.05
2.5/2.36.904.00A++A+
3.5/3.51278051.3
43/38/33/22475961
720/1,670262820206
7.0 (15)535663293
24 (53)6.35/9.52
13.8/15.8 to 16.720 (15)
15-10 to 43-15 to 24
R410A (1,975)
048
Ion Deodorization Filter
Apple-catechinFilter
Air Filter
Organic coating fin used heat exchanger
Antibacterial deodorizing pre-filter with special ceramic powder
Vertical airflow provides powerful floor level heating
Easy maintenanceSimplification of drain pan cleaning improves maintenance-ability.
Flexible InstallationAir conditioner filter features
Optional parts
Wired Remote Controller:
Simple Remote Controller:
UTY-RNNYM, UTY-RVNYM
UTY-RSNYM
Standard : ASYG18LFCA / ASYG24LFCC / ASYG30LFCA
Wall Mounted
Features
For ASYG18LFCA ASYG24LFCC
For ASYG30LFCAWireless R.C.
(18/30)(24)
Power diffuser
Power diffuser (full open)46o
(C)
15 16 17 18
Outside air conditions: 35C 40% Operation contents: Cooling, Set temperature (Min set temp) 18C,airflow Hi, Air direction upward and front
(24/30)
Outside air conditions: 2C 60% Operation contents: Heating, Set temperature (Max set temp) 30C, airflow Hi, Air direction downward and front
33 32 31 30 29
(C)
(24/30)
Horizontal airflow does not blow cool air directly at the occupants inthe room
Ion Deodorization Filter
Apple-catechin Filter
The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.
The Apple-catechin filter uses static electricity to clean fine particles and dust in the air.
Using different filters at both sides
20 m
25 m18 type
30 m
50 m30 type
20 m
30 m24 type
Max. Height
Max. Piping Length
Low ambient operation5040302010
0-10
-15C
Cooling
24CHeating
46C
-10C
049
Dimensions Models : ASYG18LFCA / ASYG24LFCC / ASYG30LFCA (Unit : mm)
998
238
320
520
520
590721
25
32
16
12
Refrigerant pipe flare connection (Liquid)
Refrigerant pipe flare connection (Gas)
Drain hose connection (Drain hose)2
1
3
Capacity
EERCOP
SEERPdesign
SCOP
Running CurrentAnnual Energy Consumption
Energy Efficiency Class
Moisture Removal Sound Pressure(Cooling)Sound Power (Cooling) Airflow Rate (High)
Net Dimension H x W x D
Drain Hose Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Max Height Difference
CoolingHeating
Piping Connections (Small / Large)
Operation Range
Refrigerant (Global Warming Potential)
HeatingCooling/HeatingInput Power
Power SourceCooling
Cooling
Indoor H/M/L/QOutdoor
Indoor
Outdoor
HighHighHigh
IndoorOutdoor
Heating
Cooling
Cooling
CoolingHeating
Cooling/Heating
Indoor / Outdoor
CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
W/W
W/W
kW
m3/h
I/h
A
kWh/a
dB(A)
mm
V/ /Hz
kW
Specifications
Model No.Indoor unit
Outdoor unit
ASYG24LFCC
AOYG24LFCC230/1/50
7.1 (0.9-8.0)8.0 (0.9-10.6)
2.20/2.213.233.61
7.1/7.16.113.80A++
A9.7/9.7
40626102.7
49/42/37/32556468
1120/2460320X998X238
14 (31)620X790X298
41 (90)6.35/15.88
12/1630 (15)
20-10 to 46-15 to 24
R410A (1,975)
ASYG30LFCA
AOYG30LFT230/1/50
8.0 (2.9-9.0)8.8 (2.2-11.0)
2.49/2.443.213.61
8.0/8.05.693.80A+A
10.9/10.7492
29413.2
48/42/37/33536468
1100/3600320X998X238
14 (31)830X900X330
61 (135)9.52/15.88
12/1650 (20)
30-10 to 46-15 to 24
R410A (1,975)
ASYG18LFCA
AOYG18LFC230/1/50
5.2 (0.9-6.0)6.3 (0.9-9.1)
1.52/1.713.423.68
5.2/5.96.943.87A++
A6.8/7.6
26221302.6
43/37/33/26505865
900/2150320X998X238
14 (31)620X790X298
41 (90)6.35/12.8
12/1625 (15)
20-10 to 46-15 to 24
R410A (1,975)
Heating (Average)
Heating (Average)
Cooling/Heating (@-10C)
050
Flexible & easy installation
Filter features
10C HEAT OperationThe room temperature can be set to go no lower than 10C, thus ensuring that the room does not get too cold when not occupied
Easy maintenanceRemovable and washable panel
2-Fan & Wide airflow
Flexible pipingconnection 6 direction ofdrain & piping
Low ambient operation
Optional parts
Wired Remote Controller:
Simple Remote Controller:
Half Concealed Kit:
UTY-RNNYM, UTY-RVNYM
UTY-RSNYM
UTR-STA
Wireless R.C.
Model : AGYG09LVCA / AGYG12LVCA / AGYG14LVCA
Floor
Features
For AGYG09/12LVCA For AGYG14LVCA
Cooling
at operationstart
at operationstart
Heating WindowPrevents cold draft from window
at stableoperation
Prevents cold air from falling
at stableoperation
Beneathstandard window
Standard concaveportion Wall
Half concealed(Optional parts necessary)
(unit:mm)
600
740200
700
(unit:mm)
Min.700
Min.590
Min.940
(unit:mm) (unit:mm)Max. 150
Min. 730 Max.80
Ion Deodorization Filter
Apple-catechin Filter
Using different filters at both sides
The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.
The Apple-catechin filter uses static electricity to clean fine particles and dust in the air.
Apple-catechin Filter
Ion Deodorization Filter
Back view
Drain hose Piping
1 62 53 4
Removable panel
50403020100
-10
43C
-15C
Cooling
24CHeating
-10C
051
Capacity
EERCOP
SEERPdesign
SCOP
Running CurrentAnnual Energy Consumption
Energy Efficiency Class
Moisture Removal Sound Pressure(Cooling)Sound Power (Cooling) Airflow Rate (High)
Net Dimension H x W x D
Drain Hose Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Max Height Difference
CoolingHeating
Piping Connections (Small / Large)
Operation Range
Refrigerant (Global Warming Potential)
HeatingCooling/HeatingInput Power
Power SourceCooling
Cooling
Indoor H/M/L/QOutdoor
Indoor
Outdoor
HighHighHigh
IndoorOutdoor
Heating
Cooling
Cooling
CoolingHeating
Cooling/Heating
Indoor / Outdoor
CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
W/W
W/W
kW
m3/h
I/h
A
kWh/a
dB(A)
mm
V/ /Hz
kW
Specifications
Model No.Indoor unit
Outdoor unit
Dimensions Models : AGYG09LVCA / AGYG12LVCA / AGYG14LVCA (Unit : mm)
AGYG14LVCA
AOYG14LVLA230/1/50
4.2 (0.9-5.0)5.2 (0.9-8.0)
1.14/1.443.683.61
4.2/4.76.404.00A++A+
5.2/6.4230
16452.1
44/38/31/22505865
650/1910600x740x200
14 (31)578x790x300
40 (88)6.35/12.7
13.8/15.8 to 16.720 (15)
15-10 to 43-15 to 24
R410A (1,975)
AGYG12LVCA
AOYG12LVCA230/1/50
3.5 (0.9-4.0)4.5 (0.9-6.6)
0.94/1.193.723.78
3.5/3.86.504.00A++A+
4.4/5.5188
13301.8
40/35/29/22485564
570/1680600x740x200
14 (31)540x790x290
36 (79)6.35/9.52
13.8/15.8 to16.720 (15)
15-10 to 43-15 to 24
R410A (1,975)
AGYG09LVCA
AOYG09LVCA230/1/50
2.6 (0.-3.5)3.5 (0.9-5.5)
0.53/0.794.914.43
2.6/2.97.004.20A++A+
2.6/3.81309671.3
40/35/29/22475564
570/1680600x740x200
14 (31)540x790x290
36 (79)6.35/9.52
13.8/15.8 to 16.720 (15)
15-10 to 43-15 to 24
R410A (1,975)
200
600
740Front view Side view
Heating (Average)
Heating (Average)
Cooling/Heating (@-10C)
052
2-stage turbo fanHigh efficiency design by 2 stage structure
Easy maintenance
High lift drain pump
Quiet qualityOptimization of wing form (laminar wing type) and wing number (7 blades each)
Compact designWorlds first 24,000Btu model in the compact cassette category (Easy installation by taking off ceiling panel of 600 x 600 size)
Optional parts
Air Outlet Shutter Plate:
Wired Remote Controller:
Simple Remote Controller:
Insulation Kit For High Humidity:
Fresh Air Intake Kit:
UTR-YDZB
UTY-RNNYM, UTY-RVNYM
UTY-RSNYM
UTZ-KXGC
UTZ-VXAA
Wireless R.C. For AUYG12/14/18LVLB
Model : AUYG12LVLB / AUYG14LVLB / AUYG18LVLB / AUYG24LVLA
Compact Cassette
Features
For AUYG24LVLA
ABCD
Grille cover2
1
3
: standard equipment
During installation, maintenance and operation, the drain pump and kit can be checked easily.
Maintenance of the fan motor and fan can be done easily after taking off the panel as the bell mouth of the fan can be removed easily. A : Fan motorC : Bell-mouth
B : 2-stage turbo fanD : Panel
1 Maintenance of fan motor and fan
2 Air filter
3 Adaptation of transparent drainage parts
700 mm
Adoption of laminar wing
Spin direction Airflow direction
Quiet
Airflow runs through smoothly along the laminar wing
No airflow separation
Laminar wingQuiet
Previous turbo fan 2-stage turbo fan
1-stage
+2-stage2 stage
Fast
Slow
Windvelocity In the case of a conventional
fan, the air outlet range was narrow as the airflow moved to the motor side which meant the velocity of air passing through the heat exchanger was uneven.
Designed by CFD-analysis (fluid) simulations
Heat exchangeefficiency:
20%UP
A evenly spread air distribution across the heat exchanger is possible due to the new 2 stage turbo fan which produces two separate airflow streams.
Low ambient operation50403020100
-10
46C
-15C
Cooling
24CHeating
-10C
053
Capacity
EERCOP
SEERPdesign
SCOP
Running CurrentAnnual Energy Consumption
Energy Efficiency Class
Moisture Removal Sound Pressure(Cooling)Sound Power (Cooling) Airflow Rate (High)
Net Dimension H x W x D
Drain Hose Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Max Height Difference
CoolingHeating
Piping Connections (Small / Large)
Operation Range
Refrigerant (Global Warming Potential)Cassette Grille
HeatingCooling/HeatingInput Power
Power SourceCooling
Cooling
Indoor H/M/L/QOutdoor
Indoor
Outdoor
HighHighHigh
IndoorOutdoor
Heating
CoolingHeating (Average)
Heating (Average)
Cooling/Heating (@-10C)
Cooling
CoolingHeating
Cooling/Heating
Indoor / Outdoor
CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
W/W
W/W
kW
m3/h
I/h
A
kWh/a
dB(A)
mm
V/ /Hz
kW
Specifications
Model No.Indoor unit
Outdoor unit
Dimensions Models : AUYG12LVLB / AUYG14LVLB / AUYG18LVLB / AUYG24LVLA (Unit : mm)
AUYG24LVLA
AOYG24LALA230/1/50
6.8 (0.9-8.0)8.0 (0.9-9.1)
2.21/2.263.083.54
6.8/6.05.603.90A+A
9.7/9.9425
21512.7
49/44/36/30525967
930/2470245570570/49x700x700
16 (35) / 2.6 (6)578x790x315
44 (97)6.35/15.88
25/3230 (15)
20-10 to 46-15 to 24
R410A (1,975)UTG-UFYD-W
AUYG18LVLB
AOYG18LALL230/1/50
5.2 (0.9-5.9)6.0 (0.9-7.5)
1.62/1.663.213.61
5.2/5.26.204.20A++A+
7.2/7.4293
17312.2
38/34/30/26505062
680/2000245570570/49x700x700
15 (33) / 2.6 (6)578x790x300
40 (88)6.35/12.70
25/3225 (15)
15-10 to 46-15 to 24
R410A (1,975)UTG-UFYD-W
AUYG14LVLB
AOYG14LALL230/1/50
4.3 (0.9-5.4)5.0 (0.9-6.5)
1.33/1.343.213.71
4.3/4.56.404.40A++A+
6.1/6.1235
14321.5
38/34/30/27495062
680/1910245570570/49x700x700
15 (33) / 2.6 (6)578790300
40 (88)6.35/12.70
25/3225 (15)
15-10 to 46-15 to 24
R410A (1,975)UTG-UFYD-W
AUYG12LVLB
AOYG12LALL230/1/50
3.5 (0.9-4.4)4.1 (0.9-5.7)
1.05/1.113.333.69
3.5/4.26.204.10A++A+
4.8/5.1198
14311.2
37/34/30/27474961
600/1780245570570/49x700x700
15 (33) / 2.6 (6)578790300
40 (88)6.35/9.52
25/3225 (15)
15-10 to 46-15 to 24
R410A (1,975)UTG-UFYD-W
285 285
Ceiling
114
114
700
700
IR receiver
570
: In
door
uni
t
370 5
40Ha
nging
bolt
pos
ition
580
to 6
60C
eilin
g op
enin
gs
530
530Hanging bolt position
Drain hose
215
19
30 123
30 262
183
Control Box
14640
Liquid pipeGas pipe
054
Optional parts
Wired Remote Controller:
Simple Remote Controller:
IR Receiver Kit:
Wide Panel:
Panel Spacer:
Air Outlet Shutter Plate:
Insulation Kit For High Humidity:
Fresh Air Intake Kit:
UTY-RNNYM, UTY-RVNYM
UTY-RSNYM
UTY-LRHYA2
UTG-AGYA-W
UTG-BGYA-W
UTR-YDZC
UTZ-KXGA
UTZ-VXGA
Model : AUYG30LRLE / AUYG36LRLE / AUYG45LRLA / AUYG54LRLA / AUYG36LRLA [3phase] / AUYG45LRLA [3phase] / AUYG54LRLA [3phase]
Cassette
Features
For AUYG30/36LRLEWired R.C. For AUYG36/45/54LRLA
Singlephase
450 mm 500 mm
WindvelocityHeat exchanger
< Motor side >
Uneven airflow
Fast
SlowConventional blade
Separation phenomenon of airflow causes noise
: Spin direction : Airflow direction : Turbulent flow noise
< Motor side >Heat exchanger
3-dimensional blade
No airflow separation
Previous turbo fan: Air passing through the heat exchanger was uneven and the air would only flow close to the ceiling.
New turbo fan: High efficiency airflow distribution has been achieved by the introduction of a 3 dimensional blade which increases the air passing over the heat exchanger.
Quiet
High efficiency turbo fan with 3-dimensional blade
Much less temperature irregularity by spreading airflow widely
Bottom view
Front part Ceiling
Rear part
Round louvre
Improvement of the airflow distribution New louvre: The louvre design distributes air leaving a space between the chassis and the ceiling allowing far and wide airflow distribution.
Ceiling panel
850 mm
High lift drain pump
DetachableGrille corner
Adjustment can be done just taking off the corner part
Adjustment of hanger position is possible after installation
Low ambient operation50403020100
-10
46C
-15C
Cooling
24CHeating
-15C
055
Capacity
EERCOP
SEERPdesign
SCOP
Running CurrentAnnual Energy Consumption
Energy Efficiency Class
Moisture Removal Sound Pressure(Cooling)Sound Power (Cooling) Airflow Rate (High)
Net Dimension H x W x D
Drain Hose Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Max Height Difference
CoolingHeating
Piping Connections (Small / Large)
Operation Range
Refrigerant (Global Warming Potential)Cassette Grille
HeatingCooling/HeatingInput Power
Power SourceCooling
Cooling
Indoor H/M/L/QOutdoor
Indoor
Outdoor
HighHighHigh
IndoorOutdoor
Heating
CoolingCooling/Heating
HeatingCoolingHeating
CoolingHeating
Cooling/Heating
Indoor / Outdoor
CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
W/W
W/W
kW
m3/h
I/h
A
kWh/a
dB(A)
mm
V/ /Hz
kW
Specifications
Model No.Indoor unit
Outdoor unit
Dimensions Models : AUYG30LRLE / AUYG36LRLE / AUYG36LRLA / AUYG45LRLA / AUYG54LRLA (Unit : mm)
AUYG54LRLA
AOYG54LATT400/3/50
14.0 (5.4-16.0)16.0 (5.8-18.0)
4.36/4.433.213.61
-----
6.5/6.6--
5.047/43/41/37
55--
2000/6900288x840x840 50x950x95026 (57) / 5.5 (12)1290900330
104 (229)9.52/15.8825.0/32.075 (30)
30-15 to 46-15 to 24
R410A (1,975)UTG-UGYA-W
AUYG45LRLA
AOYG45LATT400/3/50
12.5 (5.0-14.0)14.0 (5.4-16.2)
3.54/3.583.533.91
-----
5.3/5.3--
4.546/42/40/36
54--
1900/6900288x840x840 50x950x95026 (57) / 5.5 (12)1290900330
104 (229)9.52/15.8825.0/32.075 (30)
30-15 to 46-15 to 24
R410A (1,975)UTG-UGYA-W
AUYG36LRLA
AOYG36LATT400/3/50
10.0 (4.7-11.4)11.2 (5.0-14.0)
2.44/2.564.104.38
10.0/10.06.504.30A++A+
3.7/3.957332533.0
44/39/36/33515867
1800/6200288x840x840 50x950x95026 (57) / 5.5 (12)1290900330
104 (229)9.52/15.8825.0/32.075 (30)
30-15 to 46-15 to 24
R410A (1,975)UTG-UGYA-W
AUYG54LRLA
AOYG54LETL230/1/50
13.3 (4.5-14.5)16.0 (4.7-16.5)
4.42/4.693.013.41
-----
19.3/20.5--
5.047/43/41/37
55--
2000/6750288x840x840 50x950x95026 (57) / 5.5 (12)1290900330
86 (190)9.52/15.8825.0/32.050 (20)
30-15 to 46-15 to 24
R410A (1,975)UTG-UGYA-W
AUYG45LRLA
AOYG45LETL230/1/50
12.5 (4.0-14.0)14.0 (4.2-16.2)
3.88/3.773.223.71
-----
17.0/16.5--
4.546/42/40/36
55--
1900/6750288x840x840 50x950x95026 (57) / 5.5 (12)1290900330
86 (190)9.52/15.8825.0/32.050 (20)
30-15 to 46-15 to 24
R410A (1,975)UTG-UGYA-W
AUYG36LRLE
AOYG36LETL230/1/50
10.0 (2.8-11.2)11.2 (2.7-12.7)
3.12/3.023.213.71
10.0/8.76.304.20A++A+
13.7/13.355528973.5
43/38/36/32545769
1800/3800288x840x840 50x950x95026 (57) / 5.5 (12)
830x900x33061 (135)
9.52/15.8825.0/32.050 (20)
30-15 to 46-15 to 24
R410A (1,975)UTG-UGYA-W
AUYG30LRLE
AOYG30LETL230/1/50
8.5 (2.8-10.0)10.0 (2.7-11.2)
2.65/2.773.213.61
8.5/8.06.504.30A++A+
11.6/12.245826042.5
40/38/36/32535468
1600/3600288x840x840 50x950x95026 (57) / 5.5 (12)
830x900x33061 (135)
9.52/15.8825.0/32.050 (20)
30-15 to 46-15 to 24
R410A (1,975)UTG-UGYA-W
796Hanging bolt position
Drain hose358
840
: In
door
uni
t60
7 420
699
Hang
ing
bolt
posit
ion
860
to 9
10C
eilin
g op
enin
g
142
142
Ceiling
950IR receiver(Option)
950
(Control) Box
200
10
358 278 60
44
40
Wire holeGas pipeLiquid pipe 14
029
8(25
6)
056
Double auto swingA combination of right/left and up/down directional swing allows 3-dimensional air direction control
Easy installationMain work settings can be done easily from the remote controller at installation
Low ambient operation
Flexible installation
Optional parts
Wired Remote Controller:
Simple Remote Controller:
UTY-RNNYM, UTY-RVNYM
UTY-RSNYM
Wireless R.C.
Model : ABYG18LVTB / ABYG24LVTA
Floor/Ceiling
Features
For ABYG18LVTB For ABYG24LVTA
Floor console Under ceilingExample for floor installation Example for ceiling installation
Right and Left Swing
12
54
3
5 steps selectableStepsSwing: Cooling , Dry and Fan modeSwing: Heating and Fan mode
Up and Down Swing1
2
54
3
7 steps selectable
67
Main work settingsHigh ceiling settingAuto restart Temperature adjustment when cooling / heating
50
40
30
20
10
0
-10
-15C
Cooling
24CHeating
-10C
46C
057
Capacity
EERCOP
SEERPdesign
SCOP
Running CurrentAnnual Energy Consumption
Energy Efficiency Class
Moisture Removal Sound Pressure(Cooling)Sound Power (Cooling) Airflow Rate (High)
Net Dimension H x W x D
Drain Hose Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Max Height Difference
CoolingHeating
Piping Connections (Small / Large)
Operation Range
Refrigerant (Global Warming Potential)
HeatingCooling/HeatingInput Power
Power SourceCooling
Cooling
Indoor H/M/L/QOutdoor
Indoor
Outdoor
HighHighHigh
IndoorOutdoor
Heating
CoolingCooling/Heating
HeatingCoolingHeating
CoolingHeating
Cooling/Heating
Indoor / Outdoor
CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
W/W
W/W
kW
m3/h
I/h
A
kWh/a
dB(A)
mm
V/ /Hz
kW
Specifications
Model No.Indoor unit
Outdoor unit
Dimensions Models : ABYG18LVTB / ABYG24LVTA (Unit : mm)
ABYG24LVTA
AOYG24LALA230/1/50
6.8 (0.9-8.0)8.0 (0.9-9.1)
2.21/2.263.083.54
6.8/6.05.603.90A+A
9.7/9.9425
21502.7
48/44/40/35526167
980/2470199x990x655
27 (59)578x790x315
44 (97)6.35/15.88
25/3230 (15)
20-10 to 46-15 to 24
R410A (1,975)
ABYG18LVTB
AOYG18LALL230/1/50
5.2 (0.9-5.9)6.0 (0.9-7.5)
1.62/1.663.213.61
5.2/5.26.104.00A++A+
7.2/7.4298
18192.0
43/40/34/31505762
780/2000199x990x655
27 (59)578x790x300
40 (88)6.35/12.70
25/3225 (15)
15-10 to 46-15 to 24
R410A (1,975)
Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Drain piping connection
21
3
22
3 3
1
1
990
100 19
0
200
175
124
530 65
5
43
145
100
13634227
162
100 80 98
47 100100
124 742
5658467267
100
199
20
28
900500
058
Easy installationMain work settings can be done easily from the remote controller at installation
Fresh air intake
Condensate lift-up mechanism (Option)Optional drain lift-up mechanism allows flexible installation.
Multi auto swingA combination of right/left and up/down directional swing allows 3-dimensional air direction control.
Installation
Optional parts
Wired Remote Controller:
Simple Remote Controller:
Drain Pump Unit:
Flange:
UTY-RNNYM, UTY-RVNYM
UTY-RSNYM
UTR-DPB24T
UTD-RF204
Wireless R.C.
Model : ABYG30LRTE / ABYG36LRTE / ABYG45LRTA / ABYG36LRTA [3phase] / ABYG45LRTA [3phase] / ABYG54LRTA [3phase]
Ceiling
Features
For ABYG30/36LRTE For ABYG36/45/54LRTA
Singlephase
StepsSwing: Cooling , Dry and Fan modeSwing: Heating and Fan mode
Right and Left Swing Up and Down Swing
5 steps selectable 5 steps selectable
1
2
5
4
3
12
54
3
(Field Supplied)
Open Concealed
Wall mounted
Max.
500 mm
Low ambient operation50403020100
-10
46C
-15C
Cooling
24CHeating
-15C
OutdoorIndoor
Freshair
Setting by wireless or wired remote controller
Conventional type
1 2 3
O F F
SW1 (Optional parts)
Setting by DIP switch inside control box
Main work settingsHigh ceiling settingAuto restart Temperature adjustment when cooling / heating
059
Capacity
EERCOP
SEERPdesign
SCOP
Running CurrentAnnual Energy Consumption
Energy Efficiency Class
Moisture Removal Sound Pressure(Cooling)Sound Power (Cooling) Airflow Rate (High)
Net Dimension H x W x D
Drain Hose Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Max Height Difference
CoolingHeating
Piping Connections (Small / Large)
Operation Range
Refrigerant (Global Warming Potential)
HeatingCooling/HeatingInput Power
Power SourceCooling
Cooling
Indoor H/M/L/QOutdoor
Indoor
Outdoor
HighHighHigh
IndoorOutdoor
Heating
CoolingCooling/Heating
HeatingCoolingHeating
CoolingHeating
Cooling/Heating
Indoor / Outdoor
CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
W/W
W/W
kW
m3/h
I/h
A
kWh/a
dB(A)
mm
V/ /Hz
kW
Specifications
Model No.Indoor unit
Outdoor unit
Dimensions Models : ABYG30LRTE / ABYG36LRTE / ABYG36LRTA / ABYG45LRTA / ABYG54LRTA (Unit : mm)
ABYG45LRTA
AOYG45LATT400/3/50
12.5 (5.0-14.0)14.0 (5.4-16.2)
3.89/3.883.213.61
-----
5.8/5.8--
4.549/45/39/34
54--
2100/6900240x1660x700
46 (101)1290900330
104 (229)9.52/15.8821.5/26.075 (30)
30-15 to 46-15 to 24
R410A (1,975)
ABYG54LRTA
AOYG54LATT400/3/50
14.0 (5.4-16.0)16.0 (5.8-18.0)
4.65/4.673.013.43
-----
6.9/6.9--
5.051/48/42/38
55--
2300/6900240x1660x700
48 (106)1290900330
104 (229)9.52/15.8821.5/26.075 (30)
30-15 to 46-15 to 24
R410A (1,975)
ABYG36LRTA
AOYG36LATT400/3/50
10.0 (4.7-11.4)11.2 (5.0-14.0)
2.84/2.873.523.90
10.0/10.06.104.10A++A+
4.3/4.4573
34143.0
47/43/37/32516167
1900/6200240x1660x700
46 (101)1290900330
104 (229)9.52/15.8821.5/26.075 (30)
30-15 to 46-15 to 24
R410A (1,975)
ABYG36LRTE
AOYG36LETL230/1/50
9.4 (2.8-11.2)11.2 (2.7-12.7)
2.93/3.023.213.71
9.4/8.76.004.10A+A+
12.8/13.2548
29653.0
47/43/37/32546069
1900/38002401660700
46 (101)830x900x330
61 (134)9.52/15.8821.5/26.050 (20)
30-15 to 46-15 to 24
R410A (1,975)
ABYG30LRTE
AOYG30LETL230/1/50
8.5 (2.8-10.0)10.0 (2.7-11.2)
2.65/2.773.213.61
8.5/8.06.104.20A++A+
11.6/12.2487
26622.5
45/43/37/32535768
1660/36002401660700
46 (101)830x900x330
61 (134)9.52/15.8821.5/26.050 (20)
30-15 to 46-15 to 24
R410A (1,975)
ABYG45LRTA
AOYG45LETL230/1/50
12.1 (4.0-13.3)13.3 (4.2-15.5)
3.77/3.683.213.61
-----
16.5/16.1--
4.049/45/39/34
55--
2100/62002401660700
46 (101)1290900330
86 (189)9.52/15.8821.5/26.050 (20)
30-15 to 46-15 to 24
R410A (1,975)
Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Drain piping connection
21
3
2 1 33
16601600
700
300
130
160
192
1658833
200
150
3024082
137
160
150
65
135
202
160118
115100
160
95
060
Air-intakeAir intake direction can be selected to match the installation site.
Selectable with a wide range of static pressure
Auto Louver Grille Kit (Option)
Drain hose as standard accessoryFor flexible installation.
Slim designThe slim design allows installations where ceilings are narrow.
Flexible installation
Optional parts
Wired Remote Controller:
Simple Remote Controller:
IR Receiver Kit:
Remote Sensor Unit:
Auto Louver Grille Kit:
UTY-RNNYM, UTY-RVNYM
UTY-RSNYM
UTY-LRHYM
UTY-XSZX
UTD-GXSA-W (For ARYG12 / 14LLTB)
UTD-GXSB-W (For ARYG18LLTB)
Model : ARYG12LLTB / ARYG14LLTB / ARYG18LLTB
Slim Duct
Features
Wired R.C.
Drain port
Drain pumpbuilt-in
Height198 mm
Drain pump
Floor concealedCeiling concealed
Drain hose is standard accessory
Max.850 mm
Simple flat Auto Louver will provide comfort airflow and harmonize with luxury interior.
By using the DC fan motor, it is possible to change the static pressure rangefrom 0 to 90 Pa. The change of static pressure range is possible by remote controller.
Static pressure range0 to 90 Pa
Wired RemoteController
Wireless RemoteController
4 steps selectable and auto swing
Auto Louver Grille Duct type
Back sideBottom side
ARYG12/14LLTB ARYG118LLTB
061
Capacity
EERCOP
SEERPdesign
SCOP
Running CurrentAnnual Energy Consumption
Energy Efficiency Class
Moisture Removal Sound Pressure(Cooling)Sound Power (Cooling)Airflow Rate (High)Static pressure range (Standard)
Net Dimension H x W x D
Drain Hose Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Max Height Difference
CoolingHeating
Piping Connections (Small / Large)
Operation Range
Refrigerant (Global Warming Potential)
HeatingCooling/HeatingInput Power
Power SourceCooling
Cooling
Indoor H/M/L/QOutdoor
Indoor
Outdoor
HighHighHigh
IndoorOutdoor
Heating
CoolingCooling/Heating
HeatingCoolingHeating
CoolingHeating
Cooling/Heating
Indoor / Outdoor
CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
W/W
W/W
kW
m3/hPa
I/h
A
kWh/a
dB(A)
mm
V/ /Hz
kW
Specifications
Model No.Indoor unit
Outdoor unit
Dimensions Models : ARYG12LLTB / ARYG14LLTB / ARYG18LLTB (Unit : mm)
ARYG14LLTB
AOYG14LALL230/1/50
4.3 (0.9-5.4)5.0 (0.9-6.5)
1.33/1.343.213.71
4.3/4.55.803.90A+A
6.1/6.1259
16141.5
32/30/28/26496062
800/19100 to 90 (25)
198x700x62019 (42)
578x790x30040 (88)
6.35/12.7025/32
25 (15)15
-10 to 46-15 to 24
R410A (1,975)
ARYG12LLTB
AOYG12LALL230/1/50
3.5 (0.9-4.4)4.1 (0.9-5.7)
1.05/1.113.333.69
3.5/4.25.904.00A+A+
4.8/5.1207
14671.3
29/28/26/25475861
650/17800 to 90 (25)
198x700x62019 (42)
578x790x30040 (88)
6.35/9.5225/32
25 (15)15
-10 to 46-15 to 24
R410A (1,975)
ARYG18LLTB
AOYG18LALL230/1/50
5.2 (0.9-5.9)6.0 (0.9-7.5)
1.62/1.663.213.61
5.2/5.26.204.10A++A+
7.2/7.4293
17742.0
32/30/29/27505862
940/20000 to 90 (25)
198x900x62023 (51)
578x790x30040 (88)
6.35/12.7025/32
25 (15)15
-10 to 46-15 to 24
R410A (1,975)
ARYG12 / 14LLTB700A
BCD
EF
G
650734650
P100x6=60018x5
574
ARYG18LLTB900850934850
P100x8=80022x5
774
(Bol
t pitc
h)
G51
152
377
174
713030
F(All surroundings)
82
48
EDC
(Bolt pitch) 43
31
198
168
78
BA
10
69144264367
47557889119
163
062
Slim & Compact designIn the case of bottom return air connection, not only does the indoor unit design allow for installation in a narrow ceiling space of up to 270 mm, Further space savings have been achieved by mounting the control box internally inside the chassis.
Easy installationMain work settings can be done easily from the remote controller at installation
Easy maintenanceStructural improvement is attained by making the bottom panel two pieces, front and rear. The internal fan casing is also manufactured in two pieces, namely upper and lower. The maintenance of the motor and fan can be easily carried out by removing the rear panel and the lower part of the casing while leaving the main chassis installed.
Two-direction drain piping
Low ambient operation
Optional parts
Wired Remote Controller:
Simple Remote Controller:
Flange (Round):
Flange (Square):
Long Life Filter:
Remote Sensor Unit:
Drain Pump Unit:
IR Receiver Kit:
UTY-RNNYM, UTY-RVNYM
UTY-RSNYM
UTD-RF204
UTD-SF045T
UTD-LF25NA
UTY-XSZX
UTZ-PX1NBA
UTY-LRHYM
Model : ARYG24LMLA / ARYG30LMLE / ARYG36LMLE / ARYG45LMLA / ARYG36LMLA [3phase] / ARYG45LMLA [3phase]
Medium Static Pressure Duct
Features
(24)
Singlephase
(30/36/45