*19381212_0315*Drive Technology \ Drive Automation \ System Integration \ Services
Catalog
Synchronous ServomotorsCMP40 – CMP112, CMPZ71 – CMPZ100
Edition 03/2015 19381212/EN
SEW-EURODRIVE—Driving the world
Table of contents
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 3
Table of contents1 Introduction................................................................................................................................ 7
1.1 The SEW-EURODRIVE group of companies ................................................................. 71.2 Products and systems from SEW-EURODRIVE ............................................................ 81.3 Documentation ............................................................................................................. 111.4 Motor type notation ...................................................................................................... 121.5 Product names and trademarks ................................................................................... 121.6 Copyright notice ........................................................................................................... 12
2 Product description................................................................................................................. 132.1 CMP synchronous servomotors ................................................................................... 132.2 CMPZ synchronous servomotors – version with additional flywheel mass .................. 132.3 Features of CMP. servomotors .................................................................................... 132.4 Functional safety technology (FS) ................................................................................ 182.5 Corrosion and surface protection ................................................................................. 192.6 Important order information .......................................................................................... 212.7 Overview of the motors ................................................................................................ 23
3 Type designation..................................................................................................................... 243.1 Variants and options of the CMP. motor series ............................................................ 243.2 Sample type designation of a servomotor .................................................................... 263.3 Example of a serial number for a servomotor .............................................................. 26
4 General project planning information ................................................................................... 274.1 Standards and regulations ........................................................................................... 274.2 Circuit breaker and protective equipment .................................................................... 29
5 Project planning ...................................................................................................................... 305.1 Drive and gear unit selection data ................................................................................ 305.2 Project planning procedure .......................................................................................... 335.3 Thermal characteristics ................................................................................................ 375.4 Operating temperatures ............................................................................................... 375.5 Derating for increased ambient temperature ................................................................ 385.6 Mechanical and electrical characteristics ..................................................................... 395.7 Overhung and axial loads ............................................................................................ 435.8 Project planning example ............................................................................................. 575.9 Operation on inverter ................................................................................................... 685.10 Maximum speeds of CMP and CMPZ motors .............................................................. 70
6 Technical data of the motors.................................................................................................. 716.1 Key to the technical data .............................................................................................. 716.2 CMP40 to CMP112, 400 V system voltage .................................................................. 726.3 CMP40 to 63 with BK brake, 400 V system voltage ..................................................... 746.4 CMP71 to CMP100 with BP brake, 400 V system voltage ........................................... 756.5 CMP112 with BY brake, 400 V system voltage ............................................................ 766.6 CMPZ71 to CMPZ100, 400 V system voltage ............................................................. 776.7 CMPZ71 to CMPZ100 BY brake, 400 V system voltage .............................................. 786.8 Overview of combinations of CMP. with MOVIAXIS®, 400 V system voltage .............. 796.9 Overview of combinations of CMP. with MOVIDRIVE®, 400 V system voltage ............ 85
1938
1212
/EN
– 0
3/20
15
Table of contents
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ1004
6.10 Dynamic and thermal characteristic curves, 400 V system voltage ............................. 976.11 CMP40 to 100, 230 V system voltage ....................................................................... 1346.12 CMP40 to 63 with BK brake, 230 V system voltage ................................................... 1356.13 CMP71 to 100 with BP brake, 230 V system voltage ................................................. 1366.14 CMPZ71 to CMPZ100, 230 V system voltage ........................................................... 1366.15 CMPZ71 to CMPZ100 with BY brake, 230 V system voltage .................................... 1376.16 Overview of combinations of CMP. with MOVIDRIVE®, 230 V system voltage .......... 1386.17 Dynamic and thermal characteristic curves, 230 V system voltage ........................... 1436.18 Torque/current characteristic curves .......................................................................... 166
7 Dimension sheets for CMP. motors/brakemotors .............................................................. 1707.1 Information about dimension sheets .......................................................................... 1707.2 CMP40 S/M ................................................................................................................ 1707.3 CMP50 S/M/L ............................................................................................................. 1747.4 CMP63 S/M/L ............................................................................................................. 1807.5 CMP.71 S/M/L ............................................................................................................ 1867.6 CMP.80 S/M/L ............................................................................................................ 1987.7 CMP.100 S/M/L .......................................................................................................... 2107.8 CMP112 S/M/L/H/E ................................................................................................... 222
8 BK brakes............................................................................................................................... 2328.1 Description of BK brakes (CMP40 to CMP63) ........................................................... 2328.2 Principle of the BK brake ............................................................................................ 2338.3 General information about BK brakes ........................................................................ 2348.4 Selecting the BK brake ............................................................................................... 2358.5 Important design information ...................................................................................... 2368.6 BK brake project planning .......................................................................................... 2378.7 Technical data of BK brakes ...................................................................................... 2418.8 Dimensioning and routing of the cable ....................................................................... 2438.9 Selecting the braking contactor .................................................................................. 2438.10 Block diagram of brake control – plug connectors ..................................................... 2448.11 Block diagram of brake control – terminal box ........................................................... 2468.12 Dimensions drawings for BK brake controls .............................................................. 247
9 BP brakes............................................................................................................................... 2489.1 Description of BP brakes (CMP71 to CMP100) ......................................................... 2489.2 Principle of the BP brake ............................................................................................ 2499.3 General information about BP brakes ........................................................................ 2509.4 Selecting the BP brake ............................................................................................... 2519.5 Important design information ...................................................................................... 2529.6 BP brake project planning .......................................................................................... 2539.7 Technical data of BP brakes ...................................................................................... 2569.8 Dimensioning and routing of the cable ....................................................................... 2599.9 Selecting the braking contactor .................................................................................. 2599.10 Block diagram of brake control – plug connectors ..................................................... 2609.11 Block diagram of brake control – terminal box ........................................................... 2629.12 Dimension drawings for BP brake controls ................................................................ 263 19
3812
12/E
N –
03/
2015
Table of contents
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 5
10 BY brakes............................................................................................................................... 26410.1 Description of BY brakes (CMPZ71 to CMPZ100, CMP112) ..................................... 26410.2 Principle of the BY brake ............................................................................................ 26510.3 General information .................................................................................................... 26510.4 Selecting the BY brake ............................................................................................... 26610.5 Important design information ...................................................................................... 26710.6 BY brake project planning .......................................................................................... 26810.7 Technical data of BY brakes ...................................................................................... 27310.8 Dimensioning and routing the cable for terminal boxes ............................................. 28310.9 Selecting the braking contactor .................................................................................. 28310.10 Selecting the brake control system ............................................................................ 28410.11 Block diagram of brake control – plug connectors ..................................................... 28610.12 Block diagram of brake control – terminal box ........................................................... 29310.13 Dimension drawings for BY brake control .................................................................. 29710.14 Safety-rated BY..(FS) brakes ..................................................................................... 298
11 Motor types ............................................................................................................................ 30511.1 Standard type – encoders .......................................................................................... 30511.2 Standard type – motor protection ............................................................................... 31311.3 Standard type – connection options ........................................................................... 31611.4 Additional feature – forced-cooling fan ....................................................................... 336
12 Prefabricated cables ............................................................................................................. 34112.1 Description ................................................................................................................. 34112.2 Project planning for cable cross section ..................................................................... 34212.3 Cable assignment: CMP and CMPZ, 400 V system voltage ...................................... 34412.4 Cable assignment: CMP /VR and CMPZ /VR, 400 V system voltage ........................ 34712.5 Cable assignment: CMP /BP /BK, 400 V system voltage .......................................... 35012.6 Cable assignment: CMP /BP / BK /VR, 400 V system voltage .................................. 35212.7 Cable assignment: CMP /BY, 400 V system voltage ................................................. 35412.8 Cable assignment: CMP /BY /VR, 400 V system voltage .......................................... 35512.9 Cable assignment: CMPZ /BY, 400 V system voltage ............................................... 35612.10 Cable assignment: CMPZ /BY /VR, 400 V system voltage ........................................ 35812.11 Cable assignment: CMP and CMPZ, 230 V system voltage ...................................... 36012.12 Cable assignment: CMP /VR and CMPZ /VR, 230 V system voltage ........................ 36212.13 Cable assignment: CMP /BP /BK, 230 V system voltage ......................................... 36312.14 Cable assignment: CMP /BP /VR, 230 V system voltage .......................................... 36512.15 Cable assignment: CMPZ /BY, 230 V system voltage ............................................... 36612.16 Cable assignment: CMPZ /BY /VR, 230 V system voltage ........................................ 36712.17 Encoder cable assignment: Plug connector connection option /KKS ........................ 36812.18 Encoder cable assignment: Connection option KK .................................................... 36812.19 Forced cooling fan cables .......................................................................................... 36812.20 Structure of prefabricated cables for CMP. servomotors ........................................... 36912.21 Power cables ............................................................................................................. 37212.22 Encoder cables .......................................................................................................... 38012.23 Forced cooling fan cables .......................................................................................... 38612.24 Cable specifications of power cables ......................................................................... 388
1938
1212
/EN
– 0
3/20
15
Table of contents
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ1006
12.25 Cable specification of encoder cables ........................................................................ 39212.26 Cable specifications of forced cooling fan cables ...................................................... 394
13 Appendix ................................................................................................................................ 39613.1 Cable dimensions to AWG ......................................................................................... 396
14 Address Directory ................................................................................................................. 397
Index ....................................................................................................................................... 417
1938
1212
/EN
– 0
3/20
15
1IntroductionThe SEW-EURODRIVE group of companies
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 7
1 Introduction1.1 The SEW-EURODRIVE group of companies1.1.1 Global presence
Driving the world – with innovative drive solutions for all industries and for every appli-cation. Products and systems from SEW‑EURODRIVE are used all over the world. Beit in the automotive, building materials, food and beverage or metal-processing indus-try: The decision to use drive technology "made by SEW‑EURODRIVE" stands for reli-ability for both functionality and investment.We are represented in the most important branches of industry all over the world: with14 manufacturing plants and 79 Drive Technology Centers worldwide as well as ourcustomer support, which we consider an integrative service that continues our commit-ment to outstanding quality.
1.1.2 Always the right driveThe SEW‑EURODRIVE modular concept offers millions of combinations. This wideselection enables you to choose the correct drive for all applications, each based onthe required speed and torque range, available space, and ambient conditions. Gearunits and gearmotors offering a unique and finely tuned performance range and thebest economic prerequisites to meet your drive requirements.The modular DR.. motor series includes the energy-efficient motor types IE1 to IE4and was designed and constructed with all worldwide requirements for energy efficien-cy classes in mind. The DR.. motor easily met the requirements for approval and cer-tification in all relevant countries. The energy-efficient drives achieve the highest effi-ciency in combination with SEW‑EURODRIVE gear units.The gearmotors are electronically enhanced by MOVITRAC® frequency inverters,MOVIDRIVE® drive inverters, and MOVIAXIS® multi-axis servo inverters – a combina-tion that blends perfectly with the existing SEW‑EURODRIVE program. As is the casewith the mechanical systems, all development, production, and assembly is carried outentirely by SEW‑EURODRIVE. In combination with our drive electronics, these drivesprovide the utmost in flexibility.Products of the servo drive system, such as low backlash servo gear units, compactservomotors, or MOVIAXIS® multi-axis servo inverters ensure precision and dynamics.From single-axis or multi-axis applications to synchronized process sequences, servodrive systems from SEW-EURODRIVE enable flexible and customized implementationof your applications.For economical, decentralized installations, SEW‑EURODRIVE offers componentsfrom its decentralized drive system, such as MOVIMOT®, the gearmotor with integra-ted frequency inverter, or MOVI-SWITCH®, the gearmotor with integrated switchingand protection function. SEW‑EURODRIVE has developed hybrid cables to providecost-effective functional solutions, irrespective of the system philosophy or scope. Thelatest developments from SEW-EURODRIVE: DRC.. electronic motor, MOVIGEAR®
mechatronic drive system, MOVIFIT® decentralized drive controller, MOVIPRO® de-centralized drive, positioning, and application controller, as well as MOVITRANS® sys-tem components for contactless energy transfer.Power, quality, and robustness combined in a single standard product: withSEW‑EURODRIVE, powerful movements are delivered by industrial gear units withhigh torques. The modular concept once again ensures optimum adaptation of indus-trial gear units to meet a wide range of different applications.
1938
1212
/EN
– 0
3/20
15
1
1 IntroductionProducts and systems from SEW-EURODRIVE
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ1008
1.1.3 Your ideal partnerIts global presence, extensive product range and broad spectrum of services makeSEW‑EURODRIVE the ideal partner for the machinery and plant construction industrywhen it comes to providing drive systems for demanding drive tasks in all industriesand applications.
1.2 Products and systems from SEW-EURODRIVEThe products and systems by SEW‑EURODRIVE are divided into the following prod-uct groups:
• Industrial gear units
• Gearmotors and frequency inverters
• Servo drive systems• Decentralized drive systems• VARIOLUTION® and MAXOLUTION®
Products and systems used in several group applications are listed in a separategroup entitled "Products and systems covering several product groups". Consult thefollowing tables to locate the products and systems included in the respective productgroup:
Industrial gear units
• X, MC, ML helical and bevel-helical gear units
• P002 - 102 series planetary gear units• P.MC.., P.X.. series helical and bevel-helical planetary gear units• Application solutions with connections
– Swing base
– Gearmotor
– Motor
– Coupling
– Brake
– Lubrication system
For conveyor drives, bucket conveyors, agitators, cooling towers, crane systems, and much more.
1938
1212
/EN
– 0
3/20
15
1IntroductionProducts and systems from SEW-EURODRIVE
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 9
Gearmotors and frequency inverters
Gear units / gearmotors Motors Frequency inverters
• Helical gear units and gearmo-tors
• Parallel-shaft helical gear unitsand gearmotors
• Helical-bevel gear units andgearmotors
• Helical-worm gear units andgearmotors
• SPIROPLAN® right-angle gear-motors
• Drives for electrified monorailsystems
• Geared torque motors
• Pole-changing gearmotors
• Variable-speed gear units andgearmotors
• Aseptic gearmotors• Explosion-proof gear units and
gearmotors• Explosion-proof variable-speed
gear units and gearmotors
• Asynchronous AC motors andbrakemotors
• Pole-changing AC motors andbrakemotors
• Energy-efficient motors
• Explosion-proof AC motors andbrakemotors
• Torque motors• Single-phase motors and
brakemotors• Asynchronous linear motors
• MOVITRAC® frequency inver-ters
• MOVI4R-U® frequency inverters
• MOVIDRIVE® drive inverters• Control, technology, and com-
munication options for inverters
Servo drive systems
Servo gear units / servo gearmotors
Servomotors Servo drive inverters / servo inverters
• Low backlash planetary servogear units / planetary gearmo-tors
• Low backlash helical-bevel ser-vo gear units / helical-bevelgear units
• R, F, K, S, W gear units / gear-motors
• Explosion-proof servo gearunits / servo gearmotors
• Asynchronous servomotors /servo brakemotors
• Synchronous servomotors• Explosion-proof servomotors /
servo brakemotors• Synchronous linear motors
• MOVIDRIVE® servo drive inver-ters
• MOVIAXIS® multi-axis servo in-verters
• Control, technology and com-munication options for servodrive inverters and servo inver-ters
1938
1212
/EN
– 0
3/20
15
1
1 IntroductionProducts and systems from SEW-EURODRIVE
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10010
Decentralized drive systems
Decentralized drives Communication and installation Contactless energy transfer
• DRC.. electronic mo-tors / MOVIGEAR® mechatronicdrive system
– DBC – Direct Binary Com-munication
– DAC – Direct AS-InterfaceCommunication
– DSC – Direct SBus Commu-nication
– SNI – Single Line NetworkInstallation
• MOVIMOT® gearmotors with in-tegrated frequency inverter
• MOVIMOT® motors / brakemo-tors with integrated frequencyinverter
• MOVI‑SWITCH® gearmotorswith integrated switching andprotection function
• MOVI‑SWITCH® motors /brakemotors with integratedswitching and protection func-tion
• Explosion-proof MOVIMOT®
and MOVI‑SWITCH® gearmo-tors
• Fieldbus interfaces
• Field distributors for decentral-ized installation
• MOVIFIT® product range
– MOVIFIT® FDC for control-ling MOVIGEAR® and DRC..drive units
– MOVIFIT® MC for controllingMOVIMOT® drives
– MOVIFIT® SC with integra-ted electronic motor switch
– MOVIFIT® FC with integra-ted frequency inverter
• MOVIPRO® product line
– MOVIPRO® SDC decentral-ized drive and positioningcontrol
• MOVITRANS® system
– Stationary components forenergy supply
– Mobile components for en-ergy consumption
– Line cables and installationmaterial
VARIOLUTION® and MAXOLUTION®
• VARIOLUTION® packages for high technical solution expertise in plants and machines• MAXOLUTION® systems for customer-specific system solutions and plants
Products and systems covering several product groups
• Operator panels
• MOVI‑PLC® drive-based control system• Components of the type "functional safety"• Diagnostic units
1938
1212
/EN
– 0
3/20
15
1IntroductionDocumentation
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 11
In addition to products and systems, SEW‑EURODRIVE offers a comprehensiverange of services. These include:
• Technical consulting
• User software
• Seminars and training• Extensive technical documentation• Worldwide customer serviceVisit our website atwww.sew‑eurodrive.comThe website provides comprehensive information and services.
1.3 Documentation
1.3.1 Contents of this publicationThis catalog provides a detailed description of the following product groups offered bySEW‑EURODRIVE:• Synchronous servomotors of the CMP and CMPZ series• Options and accessories for motorsThis price catalog/catalog includes the following information:
• Type designations
• Product descriptions
• Project planning information
• Technical data
• Technical data of the options and additional features
• Dimension sheets
• Information on brakes from SEW‑EURODRIVE• Information on prefabricated cables• In the price catalog: Prices and surcharges for additional features and options
1.3.2 Additional documentationThe following documents are available from SEW-EURODRIVE in addition to this"Synchronous Servomotors" catalog:
• Synchronous servo gearmotors
• Asynchronous servo gearmotors
• AC motors
• Explosion-proof AC motors
• Gearmotors• Explosion-proof drives• Geared torque motors
1938
1212
/EN
– 0
3/20
15
1
1 IntroductionMotor type notation
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10012
1.4 Motor type notationThis catalog covers among others the motor types CMP and CMPZ.If information refers to both CMP and CMPZ motors, the notation CMP. motors isused.If information refers to either CMP or CMPZ motors, the motor type is stated explicitly.
1.5 Product names and trademarksThe brands and product names in this documentation are trademarks or registeredtrademarks of their respective titleholders.
1.6 Copyright notice© 2015 SEW‑EURODRIVE. All rights reserved.Unauthorized reproduction, modification, distribution or any other use of the whole orany part of this documentation is strictly prohibited.
1938
1212
/EN
– 0
3/20
15
2Product descriptionCMP synchronous servomotors
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 13
2 Product description2.1 CMP synchronous servomotors
The CMP servomotor series combines high dynamics, high torques, and precision in acompact design.Their innovative design with the latest in winding and magnet technology offers a mo-tor system with optimum dynamics and the best control characteristics at the smallestspace. The cast stator protects the motor against vibrations and humidity.Characteristics of SEW-EURODRIVE synchronous servomotors:
• Static torque from 0.5 to 95 Nm
• High dynamics (ratio between rated torque and mass moment of inertia of the mo-tor)
• High degree of protection (IP65)
• Robust encoder system (resolver)
• The optimal encoder system with sine/cosine encoder allows for a very wide settingrange and absolute position detection,
• High continuous torque at low speeds and at standstill, without forced cooling fan• High overload capability• NeFeB magnets, permanent magnets with high magnetic flux density.CMP motors can be optionally equipped with a holding brake and a forced cooling fan.CMP servomotors can be combined with MOVIDRIVE® inverters and MOVIAXIS® mul-ti-axis servo inverters.
2.2 CMPZ synchronous servomotors – version with additional flywheel massCMPZ synchronous servomotors are equipped with an internal additional flywheelmass. These motors combine high torques and precision in a compact design andprovide particularly favorable control characteristics with high external masses. Fur-thermore, the internal higher moment of inertia allows for a smaller gear ratio.In addition to the above mentioned features of the CMP motors, CMPZ motors are op-tionally available with a powerful BY working brake with high working capacity and op-tional manual brake release.
2.3 Features of CMP. servomotorsSynchronous servomotors with permanent magnets offer highest dynamic overloadcapacity.State-of-the-art winding and magnet technology enable a compact motor system withgreat dynamic qualities, smooth running and excellent control characteristics.
2.3.1 Standard featuresSynchronous servomotors of the CMP. series constitute a drive system that comprisesthe following elements in its basic variant:
• Smooth shaft end
• Resolver as encoder
1938
1212
/EN
– 0
3/20
15
2
2 Product descriptionFeatures of CMP. servomotors
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10014
• Thermal motor protection through temperature sensing
• Connection via adjustable plug connectors• High degree of rotational accuracy• High vibration class (DIN EN 60034‑14 grade B).
2.3.2 Optional product characteristicsCMP. motors can be optionally expanded with:
• Shaft end with key
• Forced cooling fan
• Connection via radial plug connectors
• Connection with mating connector
• Connection via terminal box
• Prefabricated cables
• Holding brake with DC 24 V brake voltage
• BK permanent magnet brake
• BY working brake with manual brake release
• Safety-rated encoder• UL or UL/CSA approval• Direct mounting to SEW gear units with B5 flangeAlternatives can be selected instead of the elements of the basic variant, e.g. absoluteencoder with Hiperface® instead of the resolver and electronic nameplate.
2.3.3 TorqueThe 7 available sizes cover a torque range from 0.5 Nm to 95 Nm.The dynamic peak torque reaches 1.9 Nm to 320 Nm.
2.3.4 Rated speedsThe optimized winding makes it possible to select one of three speeds:
• 2000 rpm
• 3000 rpm• 4500 rpm• 6000 rpm
2.3.5 Number of polesCMP motors are available with the following number of poles.
Motor Number of poles
CMP40 – CMP63 6
CMP.71 – CMP.100 10
CMP112 6
1938
1212
/EN
– 0
3/20
15
2Product descriptionFeatures of CMP. servomotors
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 15
2.3.6 Operating temperaturesMotors of the CMP series are designed for use in a temperature range between ‐20 °Cand +40 °C.Motors for cold storage applications can be used down to -40 °C. The temperaturerange from -40 °C to +10 °C is listed on the nameplate.If the motors are operated outside the specified temperature range, observe the notesin chapter Operating temperatures (→ 2 37).
2.3.7 Direct mountingCMP. servomotors can be mounted directly without adapter to the respectiveSEW‑EURODRIVE gear unit.The following gear units can be selected:
• BS.F helical-bevel servo gear units
• PS.F and PS.C planetary servo gear units
• R.. helical gear units
• F.. parallel-shaft helical gear units
• K.. helical-bevel gear units• S.. helical-worm gear units• SPIROPLAN® gear units
2.3.8 Output variantsCMP. servomotors are available with the following output types:
• Stand-alone motors with IEC/EN flange with through bores based on IEC 60072‑1:1991 and EN 50347: 2003.
• With square flange for mounting to the gear unit types BS.F, PS.F, PS.C, W10 –W30.
• With round flange for mounting to the gear unit types R, F, K, S, W37, W47. Theflange dimensions are implemented according to the SEW‑EURODRIVE workstandards for gear unit mounting.
2.3.9 Noise levelsThe noise levels of all motors from SEW‑EURODRIVE are well within the maximumpermitted noise levels set forth in IEC/EN 60034-9.
2.3.10 PaintingCMP. motors are painted with black machine paint RAL 9005 as per DIN 1843 asstandard. Special coatings and other colors are available on request.
2.3.11 Air admission and accessibilityThe motors/brakemotors must be mounted on the driven machine in such a way thatthere is enough axial and radial space left for unimpeded air admission and for per-forming maintenance on the brake.
1938
1212
/EN
– 0
3/20
15
2
2 Product descriptionFeatures of CMP. servomotors
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10016
2.3.12 BrakemotorsThe motors can be equipped with an integrated mechanical brake on request.The brake is controlled by a brake controller that is either installed in the inverter orseparately in the control cabinet.
BP brake / BK brake
BP and BK brakes are DC-operated electromagnetic disk brakes. They release electri-cally, and brake using spring force (BP brakes) or magnetic force (BK brakes). Thebrakes are applied automatically if the power fails. This means they meet the basicsafety requirements. The brakes cannot be retrofitted and usually operate withoutbrake rectifier or brake control unit.
BY brake
This is a DC-operated electromagnetic disk brake that is released electrically and ap-plied with spring force. A characteristic feature of this brake is its extremely short de-sign. The brake endshield is a part of both the motor and the brake. The integratedconstruction of the SEW‑EURODRIVE brakemotor permits particularly compact andsturdy solutions.The brake can also be released mechanically if it is equipped with manual brake re-lease. In this case, a lockable hand lever with automatic reset is included in the deliv-ery.The BY brake is also available as safety-rated brake for use in functional safety appli-cations. In this case (FS) is added to the name.
1938
1212
/EN
– 0
3/20
15
2Product descriptionFeatures of CMP. servomotors
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 17
2.3.13 International marketsOn request, SEW‑EURODRIVE supplies motors registered for the North Americanmarket or certified motors with connection conditions according to the relevant regula-tions.
Mark Meaning
CE mark to state compliance with European guidelines, such asthe Low Voltage Directive.
ATEX mark to state compliance with the European Directive94/9/EC.
UR mark to confirm that UL (Underwriters Laboratory) is informedabout the registered components; register number by UL:E337323
CSA mark to confirm the Canadian Standard Association (CSA)and the market conformity of AC motors.
EAC mark (EurAsian Conformity)
Confirms compliance with the regulations of the economic andcustoms union of Russia, Belarus and Kazakhstan.
013
UkrSEPRO mark (Ukrainian Certification of Products)
Confirms compliance with the technical regulations of the countryUkraine.
1938
1212
/EN
– 0
3/20
15
2
2 Product descriptionFunctional safety technology (FS)
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10018
2.4 Functional safety technology (FS)SEW‑EURODRIVE motors can be supplied with safety-rated components on request.SEW‑EURODRIVE indicates such an integration by the FS mark and a number on thenameplate.The number is a code that indicates which components in the motor are safety-rela-ted. See the following excerpt from the code table for all products:
Functionalsafety
Inverter Motor monitoring (e.g. motor protec-
tion)
Encoder Brake Brake monitoring (e.g. function)
Manualbrake re-
lease
01 x
02 x
03 x
04 x
05 x x
06 x x
07 x x
08 x x
09 x x
10 x x
11 x x
If the FS logo on the nameplate contains the code "FS 04", for example, the motor isequipped with a safe encoder.You can determine the safety level of machines and plants using the safety parame-ters provided in chapter "Technical data"The characteristic safety values of SEW components are also available on the SEWhomepage on the Internet and in the SEW library for the Sistema software of the Insti-tute for Occupational Safety and Health of the German Social Accident Insurance(IFA, formerly BGIA).
1938
1212
/EN
– 0
3/20
15
2Product descriptionCorrosion and surface protection
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 19
2.5 Corrosion and surface protection2.5.1 General information
SEW‑EURODRIVE offers various optional protective measures for operating motorsunder special environmental conditions.These preventive measures comprise two groups:• KS corrosion protection• OS surface protectionFor motors, optimal protection is offered through a combination of KS corrosion pro-tection and OS surface protection.
2.5.2 KS corrosion protectionKS corrosion protection for motors comprises the following measures:
• All retaining screws that are loosened during operation are made of stainless steel.
• Various motor parts are coated with a finishing varnish.• The flange contact surfaces and shaft ends are treated with a temporary rust pre-
ventive.• Additional measures for brakemotors.A sticker labeled "KORROSIONSSCHUTZ" (corrosion protection) on the motor indi-cates that special treatment has been applied.
1938
1212
/EN
– 0
3/20
15
2
2 Product descriptionCorrosion and surface protection
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10020
2.5.3 OS surface protectionIn addition to the standard surface protection, motors and gear units are available withsurface protection OS1 to OS4. The special measure "Z" is also available in addition.Special measure "Z" means that large contour recesses are filled with rubber beforepainting.
Surface protection1) Ambient conditions Sample applications
Standard Suitable for machines and systems within build-ings and interior rooms with neutral atmos-pheres.Similar to corrosivity category2) :• C1 (negligible)
• Machines and systems in theautomobile industry
• Transport systems in logistics• Conveyor belts at airports
OS1 Suited for environments prone to condensationand atmospheres with low humidity or contami-nation, such as applications outdoors underroof or with protection.According to corrosivity category2):• C2 (low)
• Systems in saw mills• Hall gates• Agitators and mixers
OS2 Suited for environments with high humidity ormoderate atmospheric contamination, such asapplications outdoors subject to direct weather-ing.According to corrosivity category2):• C3 (moderate)
• Applications in amusementparks
• Funiculars and chair-lifts• Applications in gravel plants• Systems in nuclear power
plants
OS3 Suitable for environments with high humidityand occasionally severe atmospheric andchemical contamination. Occasionally acidic orcaustic wet cleaning. Also for applications incoastal areas with moderate salt load.According to corrosivity category2):• C4 (high)
• Sewage treatment plants• Port cranes• Mining applications
OS4 Suitable for environments with permanent hu-midity or severe atmospheric or chemical con-tamination. Regular acidic and caustic wetcleaning, also with chemical cleaning agents.According to corrosivity category2):• C5-1 (very high)
• Drives in malting plants• Wet areas in the beverage in-
dustry• Conveyor belts in the food in-
dustry
1) IP56 and IP66 motors/brakemotors are only available with OS2, OS3 or OS4 surface protection.2) According to DIN EN ISO 12944-2, classification of ambient conditions
1938
1212
/EN
– 0
3/20
15
2Product descriptionImportant order information
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 21
2.6 Important order information2.6.1 Connection with plug connector
The power or power + brake of CMP. motors are connected to the motor as standardwith an adjustable, right-angle connector.The “adjustable” position was defined for angled connectors [1]. If not specified other-wise in the order, the adjustable connector position is delivered in the 270° variant.The “radial” position was defined for straight connector housings (radial output). Radialconnectors [2] are optional for sizes 40 to 100.You find detailed information about available plug connectors in chapter Connectionvariants (→ 2 322).
[1]
[2]
4792369803
[1] "Adjustable" connector position [2] "Radial" connector position
The various plug connectors of the individual motor sizes are available in varioustypes. The following table shows the options:
Connector position Plug connector
SM1/SB1 SMB/SBB SMC/SBC
Radial X X –
Adjustable Position can be chosen whenplacing the order
— – X
Positions are steplessly adjusta-ble
X X –
1938
1212
/EN
– 0
3/20
15
2
2 Product descriptionImportant order information
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10022
2.6.2 Connection with terminal box
Position of terminal box and cable entry
The product standard EN 60034 specifies that the following designations have to beused for motor terminal box positions:• As viewed onto the output shaft = A‑end• Designation as R (right), B (bottom), L (left) and T (top)This new designation applies to motors without a gear unit in mounting position B3(= M1). For gearmotors, the previous designation is retained.The position of the motor terminal box has so far been specified with 0°, 90°, 180° or270° as viewed onto the fan guard = B‑end.The following figure shows both designations. Where the mounting position of the mo-tor changes, "R", "B", "L" and "T" are rotated accordingly.The cable entry position is specified with x, 1, 2, 3.Unless other information is provided regarding the terminal box, the 270° design with"x" cable entry will be supplied (see figure below).
270°
90°
180°0°
X
X
XB
LR
T
4792373515
2 3
x
KK
CMP50 – CMP63
1
2 3
x
x
KKS
KK
CMP.71 – CMP.100, CMP112
9007204047116171
1938
1212
/EN
– 0
3/20
15
2Product descriptionOverview of the motors
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 23
2.6.3 Connecting the forced cooling fanThe position of the cable entry of the forced cooling fan is delivered as shown in thedimension sheets. Cable entry turned by 180° is available on request.
2.7 Overview of the motors2.7.1 CMP. servomotors, 230/400 V system voltage
Motor type M0 Mpk JMot CMP JMot CMPZ
Nm Nm 10-4 kgm2
CMP40S 0.5 1.9 0.10 –
CMP40M 0.8 3.8 0.15 –
CMP50S 1.3 5.2 0.42 –
CMP50M 2.4 10.3 0.67 –
CMP50L 3.3 15.4 0.92 –
CMP63S 2.9 11.1 1.15 –
CMP63M 5.3 21.4 1.92 –
CMP63L 7.1 30.4 2.69 –
CMP.71S 6.4 19.2 3.04 9.32
CMP.71M 9.4 30.8 4.08 10.37
CMP.71L 13.1 46.9 6.18 12.47
CMP.80S 13.4 42.1 8.78 27.18
CMP.80M 18.7 62.6 11.9 30.3
CMP.80L 27.5 107 18.1 36.51
CMP.100S 25.5 68.3 19.34 79.76
CMP.100M 31 108 26.25 86.66
CMP.100L 47 178.8 40 100.41
CMP112S 30 88 74 –
CMP112M 45 136 103 –
CMP112L 69 225 163 –
CMP112H 83 270 193 –
CMP112E 95 320 222 –
1938
1212
/EN
– 0
3/20
15
2
3 Type designationVariants and options of the CMP. motor series
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10024
3 Type designation3.1 Variants and options of the CMP. motor series3.1.1 Synchronous servomotors
Designation
CMP... Flange motor size 40 / 50 / 63 / 71 / 80 / 100 / 112
CMPZ... Flange motor size 71 / 80 / 100 with additional inertia / in-creased mass moment of inertia
S – E S = Small / M = Medium / L = Long / H = Huge / E = Extra long
3.1.2 Mechanical attachments
Designation Option
/BP Holding brake for CMP71 to 100
/BK Holding brake for CMP40 to 63
/BY Working brake for CMPZ71 to 100, CMP112
Optionally available as safety-rated brake for CMPZ71 to 100.
/HR BY manual brake release for CMP.71 to 100, CMP112 withautomatic disengaging function
3.1.3 Temperature sensor / temperature detection
Designation Option
/KY Temperature sensor (standard)
/TF Temperature sensor for CMP.71 to CMP112
3.1.4 Encoders
Designation Option
/RH1M Resolver (standard)
/ES1H Single-turn Hiperface® encoder, spread shaft, high resolutionfor CMP50 and CMP63
/AS1H Multi-turn Hiperface® encoder, spread shaft, high resolution forCMP50 and CMP63
/EK0H Single-turn Hiperface® encoder, cone shaft, for CMP40
/AK0H Multi-turn Hiperface® encoder, cone shaft, for CMP40 to 63,CMP.71 to 100, CMP112, optionally available as safety-ratedencoder
/EK1H Single-turn Hiperface® encoder, cone shaft, high resolution, forCMP40 to 63, CMP.71 to 100, CMP112
/AK1H Multi-turn Hiperface® encoder, cone shaft, for CMP50to 63/BK, CMP.71 to 100, CMP112, optionally available assafety-rated encoder
1938
1212
/EN
– 0
3/20
15
3Type designationVariants and options of the CMP. motor series
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 25
3.1.5 Connection options
Designation Option
/SM1 M23 motor plug connector, socket on motor end only, plugga-ble motor and encoder cables (standard)
/SMB M40 motor plug connector, socket on motor end only, plugga-ble motor and encoder cables (standard)
/SMC M58 motor plug connector, socket on motor end only, plugga-ble motor and encoder cables (standard)
/SB1 M23 brakemotor plug connector, socket on motor end only,pluggable motor and encoder cables (standard)
/SBB M40 brakemotor plug connector, socket on motor end only,pluggable motor and encoder cables (standard)
/SBC M58 brakemotor plug connector, socket on motor end only,pluggable motor and encoder cables (standard)
/KK Terminal box for CMP50, CMP63, CMP.71 to 100, clampablemotor and encoder cable
/KKS Terminal box for CMP.71 to 100, CMP112, clampable motorcable and pluggable encoder cable
3.1.6 Ventilation
Designation Option
/VR Forced cooling fan (from size 50)
1938
1212
/EN
– 0
3/20
15
3
3 Type designationSample type designation of a servomotor
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10026
3.2 Sample type designation of a servomotorThe following figure shows an example of a type designation:
Example: CMP112M /BY/HR/KY/RH1M/VR/KK
Synchronous servomotor CMP112 Flange motor size 112
Length M Medium
Mechanical attachments /BY BY working brake
Motor option /HR Manual brake release (only for BYbrake)
Standard equipment: temperaturesensor TF
/KY KY temperature sensor
Encoder motor option /RH1M Resolver (standard)
Fan motor option /VR Forced cooling fan
Connection motor option /KK Terminal box
3.3 Example of a serial number for a servomotorThe following figure shows an example of a serial number:
Example: 01. 12212343 01. 0001. 14
01. Sales organization
12212343 Order number (8 digits)
01. Order item (2 digits)
0001 Quantity (4 digits)
14 End digits of the year of manufacture (2 dig-its)
1938
1212
/EN
– 0
3/20
15
4General project planning informationStandards and regulations
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 27
4 General project planning information4.1 Standards and regulations4.1.1 Conformance to standards
Servo (brake)motors from SEW‑EURODRIVE conform to the relevant standards andregulations, in particular to:• IEC 60034‑1, EN 60034‑1Electrical rotating machinery, rating and performance.• IEC 60034-2, EN 60034‑2Rotating electrical machines, determining losses and efficiency.• IEC 60034-9, EN 60034‑9Rotating electrical machines, noise limits.• IEC 60034-14, EN 60034‑14Rotating electrical machines, vibration levels.• EN 60529, IEC 60034‑5, EN 60034‑5IP degree of protection for housings.• IEC 60072Dimensions and performance of electrical rotating machinery.• EN 50262Metric threads of cable glands.• EN 50347Standardized dimensions and power ranges.
4.1.2 Conformity with directivesServo (brake)motors from SEW‑EURODRIVE comply with the following directives:
• Low-Voltage Directive 2006/95/EC
• Machinery Directive 2006/42/EC
• EMC Directive 2004/108/EC• CSA C22.2 No.100‑04• UL 1004
1938
1212
/EN
– 0
3/20
15
4
4 General project planning informationStandards and regulations
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10028
4.1.3 Rated dataThe specific data of a synchronous servomotor are:
• Size • Static torque
• Rated speed • Rated current
• Peak current • System voltage
• Degree of protection • Thermal class
This data is given on the nameplate of the motor. In accordance with IEC 34(EN 60034), the nameplate data applies to a maximum ambient temperature of 40 °Cand a maximum altitude of 1000 m above sea level.Example: Nameplate of a CMP servo brakemotor
76646 Bruchsal/Germany3ph~IEC60034
CMPZ71M/BY/KY/RH1M/SB1
01.4108673301.0001.15
M o I o9.4 Nm 7.5 A
nN 0 - 3000 r/min
I max39.0 A
IP 65
U sys 400 V Th.Kl. F
Up 256 V Ubr 218-243 ACV Mbr20 Nm BME1.5
IM B5 kg13.544
1333 930 3 nur Umrichterbetrieb Made in Germany
M pk 30.8 Nm
VT fn 250 Hz
18014406693116939
The FS logo on the upper edge of the nameplate is only present if the motor has beendesigned accordingly and if it includes safety-rated components. The FS logo on thenameplate is based on the combination of safety-related components that is installed,see Code table (→ 2 18)The following figure shows a nameplate of a motor with UL and CSA approvals andsafety-rated components:
[2][1]
76646 Bruchsal/Germany
CMP80M/KY/AK0H/SM1
01.1900237333.0001.14
M o I o18.7 Nm 13.4 A
nN 0 - 3000 r/min
I max69.0A
IP 65
U sys 400 V Th.Kl. F
Up 283 V
3 Phase
IM B5 kg15.000
1342 168 9 Inverter duty VPWM Made in Germany
ML 01
04
M pk 62.6 Nm
VT Hzfn 250
TENV
9007207438377867
[1] FS mark including number[2] Motor identification number
1938
1212
/EN
– 0
3/20
15
4General project planning informationCircuit breaker and protective equipment
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 29
4.2 Circuit breaker and protective equipment4.2.1 Preventive measures
Synchronous servomotors must be protected against overload and short circuit.Install the motors with sufficient space for air to cool them.The surface temperature may be in excess of 100 °C during operation in accordancewith thermal classification F. Therefore, measures to prevent inadvertent contact areessential.The motors are equipped with temperature detection to protect the motor windingagainst overheating.The temperature is measured by temperature sensors KTY 84 to 130 installed asstandard, or, for sizes 71 to 112 by optionally available /TF temperature sensors. Thecorrect model must be activated in the servo inverter to enable thermal motor protec-tion (I2t, effective current monitoring). For information on the procedure, refer to thedocumentation of the servo inverter.
4.2.2 EMC measuresSEW‑EURODRIVE synchronous servomotors are intended as components for instal-lation in machinery and systems. The designer of the machine or system is responsi-ble for complying with EMC Directive 2004/108/EC.
Routing brake cables
Brake and power cables may only be routed together if either the brake cable or thepower cable is shielded. We recommend that you use prefabricated cables (→ 2 341).
Notes on encoder connection
Observe the following notes when connecting an encoder:• Use only a shielded cable with twisted pair conductors.• Connect the shield to the PE potential on both ends over a large surface area.
Thermal motor protection
The cables can only be routed together if either the KTY cable or the power cable isshielded. We recommend that you use prefabricated cables (→ 2 341).
1938
1212
/EN
– 0
3/20
15
4
5 Project planningDrive and gear unit selection data
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10030
5 Project planning5.1 Drive and gear unit selection data
The data of the application must be known for projecting a drive. The abbreviationsused for project planning are summarized in the following table:
Designation Meaning Unit
φ Rotational clearance `
η Gear unit efficiency for Mapk
a, b, f Gear unit constants as regards the overhung load conversion mm
c Gear unit constants as regards the overhung load conversion Nm
a0, a1, a2 Gear unit constants as regards the rise in temperature in the gear unit
FA Axial load (tension and compression) on the output shaft N
fk Speed ratio
FR Overhung load on the output shaft N
FRapk Maximum permitted overhung load at the output shaft for short-time duty (loadapplication point is the middle of the shaft end)
N
FRamax Maximum permitted overhung load at the output shaft for continuous duty (loadapplication point is the middle of the shaft end)
N
FRepk Maximum permitted overhung load at the input shaft for short-time duty (loadapplication point is the middle of the shaft end)
N
FRemax Maximum permitted overhung load at the input shaft for continuous duty (loadapplication point is the middle of the shaft end)
N
FRacub Cubic overhung load with cubic torque Macub N
H Installation altitude m abovesea level
I0 Current consumption of the motor at M0 A
Imax Maximum permitted motor current (root-mean-square value) A
Ins. cl. Thermal classification of the motor
i Gear unit reduction ratio
IM Gear unit mounting position (international mounting position) M1 to M6
IP.. Degree of protection according to IEC60034‑5JA Mass moment of inertia of the adapter kgm2
JG Mass moment of inertia of the gear unit kgm2
Jext Mass moment of inertia (external) reduced on motor shaft kgm2
JMot Mass moment of inertia of the motor kgm2
JL Mass moment of inertia of the load kgm2
k Inertia ratio Jext / JMot
l Length of output shaft mm
M1 – Mn Output torque in time period t1 to tn Nm
M0 Standstill torque (thermal continuous torque at low speeds) Nm
1938
1212
/EN
– 0
3/20
15
5Project planningDrive and gear unit selection data
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 31
Designation Meaning Unit
MaDYN Dynamic output torque assumed for the drive in project planning Nm
Maeff Effective torque for component testing calculated in project planning Nm
Macub Effective torque for bearing testing calculated in project planning Nm
Mamax Maximum permitted output torque for continuous duty Nm
Mapk Maximum permitted torque for short-time duty Nm
MaEmergOff Maximum permitted emergency stop torque, max. 1000 emergency stops Nm
Math Effective torque for thermal testing calculated in project planning Nm
MB Rated brake torque Nm
Mpk Dynamic limit torque of the servomotor Nm
Meff Effective torque requirement (in relation to the motor) Nm
Mmax Maximum output torque assumed for the drive in project planning Nm
ML Mounting location (UL)
napk Maximum permitted output speed for short-time duty rpm
nepk Maximum permitted input speed for short-time duty rpm
nem Mean input speed rpm
nam Mean output speed rpm
nak Breakpoint speed (output) rpm
nN Rated speed rpm
n1 – nn Output speed in time period t1 to tn rpm
netn_pk Maximum input speed in section rpm
PBr Braking power W
PBr_pk Peak braking power W
PBr_eff Effective braking power W
PBr_tn Braking power in section tn W
S.., ..% cdf Duty type and cyclic duration factor (cdf) or exact load cycle can be entered. s
t1 – tn Time period 1 to n s
tz Cycle time s
TAmb Ambient temperature °C
Usys System voltage, voltage of the supplying inverter V
UBr Operating voltage of the brake V
x Distance between overhung load application point and shaft shoulder mm
1938
1212
/EN
– 0
3/20
15
5
5 Project planningDrive and gear unit selection data
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10032
5.1.1 Determining the application dataIt is necessary to have data on the machine to be driven (mass, speed, setting range,etc.) to project the drive correctly.This data helps to determine the required power, torque and speed. Refer to the publi-cation "Drive Engineering – Practical Implementation / Drive Planning" or theSEW‑EURODRIVE project planning tool SEW Workbench for assistance.
5.1.2 Selecting the correct driveThe appropriate drive can be selected once the power and speed of the drive havebeen calculated and with regard to mechanical requirements.
1938
1212
/EN
– 0
3/20
15
5Project planningProject planning procedure
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 33
5.2 Project planning procedureThe following flowcharts show a schematic view of the project planning procedure of aservo gear unit for a positioning drive in S3 duty cycle.
5.2.1 Project planning procedure: Part 1, servo gear units
Gear unit data
3.0
ak
amk
n
nf 21=
n1
nn11am
t...t
tn...tnn
++
·++·=
EmergOffM table#
yes
no
no
akam nn #
amaxacub
K
MM
f#
THERMath MM #
maxM gear unit
n motor
from project planningSelect gear unit
1,2am
2am10THERM
n
anaaM +·+=
yes
yes
no33
1 1 1 n n n3
acub
1 1 n n
n • t • M + ...+ n • t • MM =
n • t + ... + n • t
1,2 1,2
1 1 1 n n n1,2ath
1 1 n n
n • t • M +...+ n • t • MM =
n • t +...+ n • t
Mmax
# Mapk
nmax
# nepk
yes
max
88
1 1 1 n n n8
aeff
1 1 n n
n • t • M + ...+ n • t • MM =
n • t + ... + n • t
aeffM #
amaxM
yes
no
no
ja
*
Check gear unit /
check application
9007204389640459
* For thermal project planning of R, F, K, S, W gear units, please contactSEW‑EURODRIVE.
1938
1212
/EN
– 0
3/20
15
5
5 Project planningProject planning procedure
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10034
5.2.2 Project planning procedure: Part 2, servo gear units
x = l/2
Project planning
finished
Z0
maxRmax f
d
2000 M F ·
·=
cF
f x+Rmax
yes
Coupling operation
yes
no
no
no
yes
yes
RaPk
aFRmax b x+
·
RaPkRmax F F #
yes
Check gear unit /
check application
Z0
acubRcub f
d
2000 M F ·
·=
x = l/2
RamaxRcub F F #
#F
#
no
no
yes
yes
yes
Ramax
aFRcub b x+
·#F no
no
no
yes
9007204389655947
For preloaded drives (toothed belts, flat belts, narrow belts, and pinion / gear rack), thecubic overhung load (FRcub) equals the maximum overhung load (FRmax).
1938
1212
/EN
– 0
3/20
15
5Project planningProject planning procedure
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 35
5.2.3 Project planning procedure: Part 3, servomotors
eff Nom
Operating point
below or max. on the
thermal characteristic curve
M M≤
no
e max
Determine the
maximum
input torque M
k 15≤
yes
pk
Preliminary determination
of the motor by means of
the torque M
Determine mass
inertia ratio "k"
Determine motor torques
for all
travel sections
yes
Determine
the operating point
no
Determine the
effective motor torque
++= ntnM...tM
ZteffM
2
1
2
11
++= ntnn...tn
zteffn
1.51
1.51
Determine the
thermal effective speed
1.5
×
× × ×( )
× ×
maxmaxe
i
MM
η=
9007204389658635
1938
1212
/EN
– 0
3/20
15
5
5 Project planningProject planning procedure
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10036
5.2.4 Project planning procedure: Part 4, servomotors
eff
Select controller in
selection tables using
the effective torque M
Calculate the peak braking power
End
max
Check dynamic
limit torque
#
Calculate the mean braking power
Select braking resistor
in the "assignment table
braking resistor – inverter"
using the max. braking and the mean
yes
no
Select more components,
such as encoder interfaces
and perhaps
fieldbus cards, etc.
M of the motorpkM
braking power
power
yes
and max. motor torque Mpk
*
*
Z
nt_Brt_Br
Brt
tn
P...PP
´++=
1
9550
Loadte_Br
nMP
η××=
pkpk
9007204389661323
* MOVIDRIVE® system manual, MOVIAXIS® system manual
1938
1212
/EN
– 0
3/20
15
5Project planningThermal characteristics
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 37
5.3 Thermal characteristics5.3.1 Notes on selecting synchronous servomotors
Project planning for a servomotor involves the following tasks for determining the ther-mal and dynamic load on the motor:
• Calculating the effective operating point for checking the thermal load on the mo-tor.
• Calculating the maximum operating point for determining the motor/inverter com-bination.
• Determining the inertia ratio Jext/JMot for checking the stability of the speed control.
5.3.2 Procedure
• Determining the maximum speed based on aspects of the inertia ratioJext / JMot< 15.
• Maximum required torque Mmax at maximum speed nmax (maximum operatingpoint).
Mmax < Mdyn_Mot when nmax
Mdyn_Mot corresponds to the maximum torque with the specific motor/inverter com-bination. This operating point must lie below the characteristic curve for the maxi-mum torque of the motor/MOVIDRIVE®/MOVIAXIS® motor combination.
• Effective torque demand at the average speed of the application (effective operat-ing point).
Meff < MN_Mot when nmedium
This operating point must lie below the characteristic curve for continuous torqueto ensure thermal stability of the drive.
5.4 Operating temperatures5.4.1 Maximum ambient temperature
CMP motors are designed for use in a temperature range between -20 °C and +40 °C.
5.4.2 Higher operating temperaturesCMP servomotors can optionally be used at a maximum ambient temperature of 60°C.Please contact SEW‑EURODRIVE if the motors are used at higher ambient tempera-tures. See also chapter Derating for increased ambient temperature (→ 2 38).
INFORMATIONIf the motor is operated at higher ambient temperatures, also take account of theproject planning for the power cable.
5.4.3 Cold storage applicationTaking suitable measures, motors can be used for cold storage applications up to-40 °C. The temperature range from -40 °C to +10 °C is listed on the nameplate.
1938
1212
/EN
– 0
3/20
15
5
5 Project planningDerating for increased ambient temperature
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10038
5.5 Derating for increased ambient temperatureFor projecting the CMP synchronous servomotors with permanent-magnet excitation,the following derating applies in the ambient temperature range +40 °C to + 60 °C:• The thermal speed/limit torque characteristic curve is re-scaled towards the origin
(minimized). The thermal operating point based on effective torque and thermallyeffective speed of the application must be below the re-scaled characteristic curve.
M0
M0 (Tu)
n0n0(Tu)
4793062795
−=
105°C
145°C TMM (T )0 0
x UU
−=
105°C
145°C TKn (T )0 e
x UU
n0x
TA Ambient temperature [°C]
M0 Static torque under nominal conditions
M0(TA) Standstill torque at increased temperatures 40 °C < TA < 60 °C
n0 Thermal limit speed under nominal conditions
n0(TA) Thermal limit speed at increased temperatures 40 °C < TA < 60 °C
Ke Encoder factor for resolver = 1; for electronic encoder (e.g. Hiperface® en-coder) = 0.9
1938
1212
/EN
– 0
3/20
15
5Project planningMechanical and electrical characteristics
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 39
5.6 Mechanical and electrical characteristics
Design CMP40 / 50 / 63 / 71 / 80 / 100 / 112
Standard Optional
Degree of protection IP65 IP66
Thermal class 155 (F) –
Motor protection KTY TF
Connection Adjustable plug con-nector
Radial plug connector (notCMP112), terminal box
(CMP50 to 112)
Shaft end Smooth With key, domed type A
Ambient temperature -20 °C to +40 °C -20 °C to +60 °C
-40 °C to +10 °C
Standard/regulations CE
VDE
CSA / UL
UL
Noise levels according toEN 60034
Below specified value –
Feedback 2-pole resolver Hiperface® encoder
Brake – BP: CMP71 – 100
BK: CMP40 – 63
BY: CMP.71 – 100, CMP112
Cooling Convection Forced cooling fan forCMP50 to CMP112
Vibration class "B" to EN 60034-14
Number of poles CMP40 – 63: 6
CMP.71 – 100: 10
CMP112: 6
–
1938
1212
/EN
– 0
3/20
15
5
5 Project planningMechanical and electrical characteristics
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10040
5.6.1 Speed classes, rated speedsSpeed classes (rated speeds) of synchronous servomotors:
• 2000 rpm
• 3000 rpm• 4500 rpm• 6000 rpmAs synchronous servomotors operate as controlled drives, it is necessary to considerthe inertia ratio between the load and the motor. This ratio is a decisive factor in deter-mining the quality of closed-loop control. The inertia ratio should not exceed the val-ues listed in the table below.Reduction of the inertia ratio using the motor speed or the selected gear unit reductionratio offers hardly any advantage with respect to closed-loop control starting at the val-ue Jext / JMot < 8.Backlash and elasticity negatively influence the possible dynamic response of thedriveline and must be kept to a minimum.As a result, the maximum speed should be selected such that the following criteria aremet:
Driveline Control characteristics Inertia ratio Jext/ / JMot
Forged gear rack, re-duced backlash gear unit
Low backlash and low elasticitydrive
Jext / JMot < 15
Toothed belt, reducedbacklash gear unit
Common servo applications Jext / JMot < 15
Toothed belt, standardgear unit
Standard applications, cou-plings with torque buffer (elas-ticity)
Jext / JMot < 10
1938
1212
/EN
– 0
3/20
15
5Project planningMechanical and electrical characteristics
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 41
5.6.2 Degree of protection to EN 60034 (IEC 60034‑5)Synchronous servomotors are supplied with IP65 degree of protection as standard.
IP 1st digit 2nd digit
Touch guard Protection against for-eign objects
Protection against wa-ter
0 No protection No protection No protection
1 Protected against accessto hazardous parts withthe back of your hand
Protection against solidforeign objects Ø 50 mm
and larger
Protection against drip-ping water
2 Protected against accessto hazardous parts with a
finger
Protection against solidforeign objects Ø 12 mm
and larger
Protection against drip-ping water when tilted up
to 15°
3 Protected against accessto hazardous parts with a
tool
Protection against solidforeign objects Ø 2.5 mm
and larger
Protection against spray-ing water
4 Protected against accessto hazardous parts with a
wire
Protection against solidforeign objects Ø 1 mm
and larger
Protection against splash-ing water
5 Dust-proof Protection against waterjets
6 Dust-proof Protection against power-ful water jets
7 – – Protection against tempo-rary immersion in water
8 – – Protection against perma-nent immersion in water
9 – – Protection against waterpenetration from any di-rection even under in-
creased pressure againstthe housing
1938
1212
/EN
– 0
3/20
15
5
5 Project planningMechanical and electrical characteristics
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10042
5.6.3 Applications
High accelerations
The rotor of the CMP synchronous servomotor is designed to be low-inertia. Thesemotors are the optimum choice in very dynamic applications. For high accelerationsand accelerations in the millisecond range, the synchronous servomotor is usually thetechnically and economically best solution.
Additional flywheel mass
The rotor of the CMPZ synchronous servomotor is equipped with an additional fly-wheel mass. This additional flywheel mass allows for handling large external masses.
Cogging
The motors produce small torque ripple due to the servo drive design. This torque rip-ple is corrected by the inverter.
1938
1212
/EN
– 0
3/20
15
5Project planningOverhung and axial loads
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 43
5.7 Overhung and axial loadsThe following overhung loads are determined by subjecting the shaft to a load with therated torque.The permitted overhung loads FR at point x are determined via the following diagrams."x" is the distance between the shaft shoulder and the force application (→ 2 44).The diagrams are based on the following nominal bearing service life:
Motor type Nominal bearing service life
CMP40 L10h = 25000 h
CMP50 L10h = 25000 h
CMP63 L10h = 20000 h
CMP.71 L10h = 25000 h
CMP.80 L10h = 25000 h
CMP.100 L10h = 25000 h
CMP112 L10h = 25000 h
5.7.1 Ball bearing types used (standard)The following table shows approved ball bearing types:
Motor type A-side bearing B-side bearing
CMP40 6002-2Z-C3 6001-2Z-C3
CMP50 6004-2Z-C3 6001-2Z-C3
CMP63 6005-2Z-C3 6003-2Z-C3
CMP.71 6206-2Z-J-C3 6202-2Z-J-C3
CMP.80 6307-2Z-J-C3 6304-2Z-J-C3
CMP100 6309-2Z-J-C3 6304-2Z-J-C3
CMPZ100, CMP100 /BP 6309-2Z-J-C3 6205-2Z-J-C3
CMP112 6311-2Z-C3 6207-2Z-C3
The grease fill and the bearing sealing can vary depending on the operational environ-ment.
1938
1212
/EN
– 0
3/20
15
5
5 Project planningOverhung and axial loads
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10044
5.7.2 Permitted overhung and axial loads for x = l / 2 (shaft center)
R
4795970187
CMP40 – 63
Motor type FR max in N Mean speed1) in rpm
FA in N 1500 3000 4500 6000
CMP40S FR max 330 260 225 205
FA 109 86 74 68
CMP40M FR max 350 280 245 220
FA 116 92 81 73
CMP50S FR max 475 315 250 200
FA 157 104 83 66
CMP50M FR max 510 355 275 220
FA 168 117 91 73
CMP50L FR max 550 370 280 225
FA 182 122 92 74
CMP63S FR max 680 460 360 290
FA 224 152 119 96
CMP63M FR max 750 500 380 300
FA 248 165 125 99
CMP63L FR max 830 560 445 360
FA 274 185 147 1191) The mean speed must be determined, for example, from the travel diagram.
1938
1212
/EN
– 0
3/20
15
5Project planningOverhung and axial loads
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 45
CMP.71 – CMP.100, CMP112
Motor type FR max in N Mean speed1) in rpm
FA in N 2000 3000 4500 6000
CMP.71S FR max 953 832 724 636
FA 318 277 240 212
CMP.71M FR max 1018 888 747 659
FA 340 296 250 219
CMP.71L FR max 1101 928 777 681
FA 367 309 258 227
CMP.80S FR max 1666 1454 1270 1132
FA 555 485 423 377
CMP.80M FR max 1782 1555 1325 1169
FA 594 518 442 390
CMP.80L FR max 1928 1635 1372 1208
FA 643 544 457 402
CMP.100S FR max 2708 2364 2064 –
FA 903 788 688 –
CMP.100M FR max 2882 2515 2195 –
FA 961 838 732 –
CMP.100L FR max 3099 2694 2278 –
FA 1033 897 759 –
CMP112S FR max 3791 3308 2886 –
FA 1264 1103 962 –
CMP112M FR max 3953 3448 3008 –
FA 1318 1149 1003 –
CMP112L FR max 4102 3456 2898 –
FA 1367 1152 966 –
CMP112H FR max 4118 3465 2900 –
FA 1373 1155 967 –
CMP112E FR max 4126 3467 2896 –
FA 1376 1156 966 –1) The mean speed must be determined, for example, from the travel diagram.
1938
1212
/EN
– 0
3/20
15
5
5 Project planningOverhung and axial loads
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10046
Permitted overhung load for CMP40S400
X [mm]
FR
[N
]
350
300
250
200
150
100
50
0
0 5 10 15 20 25
n = 4500 min-1
n = 3000 min-1
n = 6000 min-1
n = 1500 min-1
9007204050713867
Permitted overhung load for CMP40M400
X [mm]
350
300
250
200
150
100
50
0
0 5 10 15 20 25
n = 3000 min-1
n = 4500 min-1
n = 6000 min-1
n = 1500 min-1
FR
[N
]
9007204050716555
1938
1212
/EN
– 0
3/20
15
5Project planningOverhung and axial loads
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 47
Permitted overhung load for CMP50S600
X [mm]
500
400
300
200
100
0
0 5 10 15 20 25
n = 3000 min-1
n = 4500 min-1
n = 6000 min-1
n = 1500 min-1
FR
[N
]
9007204050719243
Permitted overhung load for CMP50M600
X [mm]
500
400
300
200
100
0
0 5 10 15 20 25
n = 3000 min-1
n = 4500 min-1
n = 6000 min-1
n = 1500 min-1
FR
[N
]
9007204050721931
1938
1212
/EN
– 0
3/20
15
5
5 Project planningOverhung and axial loads
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10048
Permitted overhung load for CMP50L600
X [mm]
500
400
300
200
100
0
0 5 10 15 20 25
n = 3000 min-1
n = 4500 min-1
n = 6000 min-1
n = 1500 min-1
FR
[N
]
9007204050724619
Permitted overhung load for CMP63S800
X [mm]
700
600
500
400
300
200
100
0
0 5 10 15 20 25 30 35
n = 3000 min-1
n = 4500 min-1
n = 6000 min-1
n = 1500 min-1
FR
[N
]
9007204050727307
1938
1212
/EN
– 0
3/20
15
5Project planningOverhung and axial loads
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 49
Permitted overhung load for CMP63M
800
X [mm]
900
1000
700
600
500
400
300
200
100
0
0 5 10 15 20 25 30 35
n = 3000 min-1
n = 4500 min-1
n = 6000 min-1
n = 1500 min-1
FR
[N
]
9007204050729995
Permitted overhung load for CMP63L
800
X [mm]
900
1000
700
600
500
400
300
200
100
0
0 5 10 15 20 25 30 35
n = 3000 min-1
n = 4500 min-1
n = 6000 min-1
n = 1500 min-1
FR
[N
]
9007204050732683
1938
1212
/EN
– 0
3/20
15
5
5 Project planningOverhung and axial loads
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10050
Permitted overhung load for CMP.71S
400
500
600
700
800
900
1000
1100
1200
1300
0 10 20 30 40 50
X [mm]
n = 3000 min-1
n = 4500 min-1
n = 6000 min-1
n = 2000 min-1
FR
[N
]
9007204050735371
Permitted overhung load for CMP.71M
400
500
600
700
800
900
1000
1100
1200
1300
0 10 20 30 40 50
X [mm]
n = 3000 min-1
n = 4500 min-1
n = 6000 min-1
n = 2000 min-1
FR
[N
]
9007204050738059
1938
1212
/EN
– 0
3/20
15
5Project planningOverhung and axial loads
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 51
Permitted overhung load for CMP.71L
400
500
600
700
800
900
1000
1100
1200
1300
0 10 20 30 40 50
X [mm]
n = 3000 min-1
n = 4500 min-1
n = 6000 min-1
n = 2000 min-1
FR
[N
]
9007204050740747
Permitted overhung load for CMP.80S
900
1100
1300
1500
1700
1900
2100
2300
0 10 20 30 40 50 60X [mm]
n = 3000 min-1
n = 4500 min-1
n = 6000 min-1
n = 2000 min-1
FR
[N
]
9007204050743435
1938
1212
/EN
– 0
3/20
15
5
5 Project planningOverhung and axial loads
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10052
Permitted overhung load for CMP.80M
900
1100
1300
1500
1700
1900
2100
2300
0 10 20 30 40 50 60
X [mm]
n = 3000 min-1
n = 4500 min-1
n = 6000 min-1
n = 2000 min-1
FR
[N
]
9007204050746123
Permitted overhung load for CMP.80L
900
1100
1300
1500
1700
1900
2100
2300
0 10 20 30 40 50 60
X [mm]
n = 3000 min-1
n = 4500 min-1
n = 6000 min-1
n = 2000 min-1
FR
[N
]
9007204050748811
1938
1212
/EN
– 0
3/20
15
5Project planningOverhung and axial loads
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 53
Permitted overhung load for CMP.100S
1100
1300
1500
1700
1900
2100
2300
2500
2700
2900
3100
3300
0 10 20 30 40 50 60
X [mm]
n = 3000 min-1
n = 4500 min-1
n = 2000 min-1
FR
[N
]
9007204050751499
Permitted overhung load for CMP.100M
1100
1300
1500
1700
1900
2100
2300
2500
2700
2900
3100
3300
0 10 20 30 40 50 60X [mm]
n = 3000 min-1
n = 4500 min-1
n = 2000 min-1
FR
[N
]
9007204050754187
1938
1212
/EN
– 0
3/20
15
5
5 Project planningOverhung and axial loads
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10054
Permitted overhung load for CMP.100L
1100
1300
1500
1700
1900
2100
2300
2500
2700
2900
3100
3300
3500
0 10 20 30 40 50 60X [mm]
n = 3000 min-1
n = 4500 min-1
n = 2000 min-1
FR
[N
]
9007204050756875
Permitted overhung load for CMP112S
X [mm]
2000
2500
3000
3500
4000
4500
0 10 20 30 40 50 60 70 80 90
n = 4500 min-1
n = 3000 min-1
n = 2000 min-1
FR
[N
]
9007208142963083
1938
1212
/EN
– 0
3/20
15
5Project planningOverhung and axial loads
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 55
Permitted overhung load for CMP112M
2000
2500
3000
3500
4000
4500
5000
0 10 20 30 40 50 60 70 80 90
X [mm]
n = 4500 min-1
n = 3000 min-1
n = 2000 min-1F
R [
N]
9007208142961163
Permitted overhung load for CMP112L
2000
2500
3000
3500
4000
4500
5000
0 10 20 30 40 50 60 70 80 90
X [mm]
n = 4500 min-1
n = 3000 min-1
n = 2000 min-1
FR
[N
]
9007208142959243
1938
1212
/EN
– 0
3/20
15
5
5 Project planningOverhung and axial loads
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10056
Permitted overhung load for CMP112H
2000
2500
3000
3500
4000
4500
5000
0 10 20 30 40 50 60 70 80 90
X [mm]
n = 4500 min-1
n = 3000 min-1
n = 2000 min-1F
R [
N]
9007208142957323
Permitted overhung load for CMP112E
2000
2500
3000
3500
4000
4500
5000
0 10 20 30 40 50 60 70 80 90
X [mm]
n = 4500 min-1
n = 3000 min-1
n = 2000 min-1
FR
[N
]
9007208142965003
1938
1212
/EN
– 0
3/20
15
5Project planningProject planning example
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 57
5.8 Project planning exampleIn the example, a gantry with synchronous servomotors is determined.The symbols used in the equations are explained in chapter Drive and gear unit selec-tion data (→ 2 30).
5.8.1 Selecting the x-axis (travel axis)
Gantry with servo drives – travel axis
Reference data:
• Total moved mass: mL = 50 kg
• Diameter of the belt pulley: d0 = 75 mm
• Friction coefficient of the axis: µ = 0.01
• Travel speed: vmax = 2 m/s
• Maximum acceleration/deceleration: amax = 10 m/s2
• Cycle time: tz = 3 s
• Pause time: tp = 1.8 s• Load efficiency: ηL = 0.9• Mounting position of the gear unit: IM = M1For the drive, a PC.C gear unit is designed to be mounted directly to a CMP servomo-tor.The overhung load is to act on the shaft center.Power is transmitted via a belt pulley.
1938
1212
/EN
– 0
3/20
15
5
5 Project planningProject planning example
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10058
Travel sections
Diagram: Travel sections 1 to 4
t [s]
v
[m/s]
1 2 3 4
9007204051282699
Acceleration time in travel section 1, deceleration time in travel section 3
t = tv
as1 = = =
2 m/s
10 m/s
0.223
max
max
Travel time for constant travel in travel section 2
t t t t t
t
t
z p2 1 3
2
2 0 8 s
= - - -
= .
= 3 s - 1.8 s - 0.2 s - 0.2 s
Mstat for all travel sections
M
m gd
M
kgm
s
m
stat
L
stat
=
· ·( ) ·
=
· ·
·
µ
η
0
2
2
50 9 81 0 010 075
2
0
. ..
.99
0 2043M Nmstat = .
9007204051559563
Mdyn during acceleration in travel section 1
M
m ad
M
kgm
s
m
M
dyn
L
dyn
dyn
=
·( ) ·
=
·
·
=
0
2
2
50 100 075
2
0 9
20 83
η
.
.
. NNm
9007204051562251
1938
1212
/EN
– 0
3/20
15
5Project planningProject planning example
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 59
Mdyn during deceleration in travel section 3
M m ad
M kgm
s
m
M
dyn
dyn
dyn
= · · ·
= · -
· ·
= -
0
2
2
50 100 075
2
0 9
16
η
..
.8875Nm
L
( )
Mmax during acceleration in travel section 1
M M M
M Nm Nm
M Nm
stat dynmax
max
max
. .
.
= +
= +
=
1
0 2043 20 8333
21 04
9007204051567627
Mmax during deceleration in travel section 3
M M M
M Nm Nm
M Nm
stat dynmax
max
max
. .
.
= +
= + -( )
= -
3
0 2043 16 87
16 6657
Output speed
nv
d
n
m
s
m
n
a
a
a
max
max
max
max
.
.min
=·
·
=·
·
=
0
60
2
0 07560
509 2951
π
π
4796832011
Gear ratio including 10% motor speed reserve
nN = 4500 rpm is an assumption
in
n
i
i
N
a
=·
=
·
=
max
min0.9
.min
7.95
45001
509 2951
0.9
4796834699
1938
1212
/EN
– 0
3/20
15
5
5 Project planningProject planning example
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10060
Maximum input speed
n n i
n
n
amax max
max
max
.min
.min
= ·
= ·
=
509 2951
7
3565 0651
Servo gear unit project planning
The gear unit is selected on the basis of the table belowcT FRa FRapk
Mamax Mapk MaEmergOff nak JG PSC PSC PSCi Nm Nm Nm rpm 10-4kgm2 Nm/" N N
PSC221
1
3 29 40 60 1500 0,172 3.46 1170 20005 34 42 63 720 0.0578 3.44 1390 20007 32 39 59 800 0.03 3.28 1550 200010 30 37 56 700 0.0144 2.92 1750 2000
M1;M3;M5-6 M2 M4 ϕnepk η a0 a1 a2 a0 a1 a2 a0 a1 a2
i rpm % 'PSC221
1
3 7000 99 101.00 -0,093 0 106.00 -0,104 0 109.00 -0,110 0 105 7000 99 160.00 -0,181 0 163.00 -0,190 0 167.00 -0,200 0 107 7000 99 186.00 -0,257 0 187.00 -0,264 0 186.00 -0,267 0 1010 7000 99 158.00 -0,178 0 161.00 -0,184 0 164.00 -0,194 0 10
Selection condition:Mmax ≤ Mapk
21.04 Nm ≤ 39 Nmnmax ≤ nepk
3565 rpm ≤ 7000 rpmCondition is fulfilled.
Mean output speed
+ ·n
n t n t
t t
n
s
am
n n
n
am
=· +
+ +
=
· +
1 1
1
509 2951
20 2 50
... ...
... ...
.min
. 99 2951
0 8
509 2951
20 2
0 2 0 8 0 2 1 8
16
.min
.
.min
.
. . . .
· + ·
+ + +
=
s s
s s s s
nam
99 7651
.min
9007204051585419
Selection condition:nam ≤ nak
169.765 rpm ≤ 809 rpmCondition is fulfilled.
19
3812
12/E
N –
03/
2015
5Project planningProject planning example
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 61
Effective torque of servo gear unit
Mn t M n t M
n t n t
M
aeff
n n n
n n
aeff
=· · + + · ·
· + + ·
=
1 1 1
8
1 1
8
509
... ...
...
. 22951
20 2 21 04 509 295
10 8 0 2043
506 2958min
. . .min
. .
.
· · + · · +s Nm s Nm
11
20 2 16 67
0 2 254 641
0 8 509 2951
0 2
8min. .
. .min
. .min
.
· · -
· + · +
s Nm
s s s ··
=
254 641
16 065
8
.min
.M Nmaeff
8
8
9007204051589771
Selection condition:Maeff ≤ Mamax
16.065 Nm ≤ 32 NmCondition is fulfilled.
Thermal torque of servo gear unit
Mn t M n t M
n t n t
M
ath
n n n
n n
ath
=· · + + · ·
· + + ·
=
1 1 1
1 1
1.2
509
... ...
...
. 22951
20 2 21 04 509 295
10 8 0 2043
506 295min
. . .min
. .
.
· · + · · +s Nm s Nm
11
20 2 16 67
0 2 254 641
0 8 509 2951
0 2
min. .
. .min
. .min
.
· · -
· + · +
s Nm
s s s ··
=
254 641
.min
ath
1.2 1.2
1.2
1.2 1.2 1.2
M 5.009Nm
9007204051594123
Thermal factors for mounting position M1a0 = 186a1 = -0.257a3 = 0
M a a na
n
M
Therm am
am
Therm
= + · +
= + - ·
0 1
2
1 2
186 0 257 169 7651
.
. .min
+
=
0
169 765
142 37
1 2.
.
,
M NmTherm
( )
Selection condition:Math ≤ MTherm
5.035 Nm ≤ 142.37 NmCondition is fulfilled.
1938
1212
/EN
– 0
3/20
15
5
5 Project planningProject planning example
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10062
Overhung load calculation
FM
df
FNm
m
F N
R z
R
R
max
max
max
max
.
..
= ·
= ·
=
0
2
21 04
0 075
2
2 5
1402
4796859147
The force application point is the center of the output shaft.Selection condition:FRmax ≤ FRaPk
1402 N ≤ 2000 NCondition is fulfilled.
Calculation of the overhung load on the shaft end
s N
Mn t M n t M
n t n t
M
akub
n n n
n n
akub
=· · + + · ·
· + + ·
=
1 1 1
3
1 1
3
509
... ...
...
. 22951
20 2 21 04 509 295
10 8 0 2043
506 295min
. . .min
. .
.
· · + · · +m s Nm
11
20 2 16 67
0 2 254 641
0 8 509 2951
0 2
3min. .
. .min
. .min
.
· · -
· + · +
s Nm
s s s ··
=
= ·
=
254 641
11 172
2
11 12
0
3
0
.min
.
.
M Nm
FM
df
FNm
akub
Rkub
akub
z
Rkub.
.
.
075
2
2 5
744 8
m
F NRkub
·
=
3
33
9007204051604491
Selection condition:FRkub ≤ FRmax
744.8 N ≤ 1402 NCondition is fulfilled.
1938
1212
/EN
– 0
3/20
15
5Project planningProject planning example
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 63
Load torques in travel sections 1 to 3
Travel section 1
MM
i
MNm
M Nm
e
dyn
G
e
e
max
max
max
.
.
.
1
1
1
1
21 04
7 0 99
3 036
=·
=·
=
η
Travel section 2
MM
i
MNm
M Nm
e
stat
G
e
e
max
max
max
.
.
.
2
2
2
0 2043
7 0 99
0 0294
=·
=·
=
η
Travel section 3
MM
i
MNm
M Nm
e
dyn G
e
e
max
max
max
. .
.
3
3
3
3
16 67 0 99
7
2 357
=·
=- ·
= -
η
1938
1212
/EN
– 0
3/20
15
5
5 Project planningProject planning example
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10064
5.8.2 Motor selectionPreliminary determination of motor using torque Mpk.
nN Motor M0 I0 Mpk Imax M0VR I0VR Jmot Jbmot MB1 MB2 L1 R1 Vp0 cold
rpm Nm A Nm A Nm A kgcm2 Nm mH Ω V
4500 CMP40S 0.5 1.2 1.9 6.1 - - 0.1 0.13 0.85 -- 23 11.94 27.5
CMP40M 0.8 0.95 3.8 6.0 - – 0.15 0.18 0.95 -- 45.5 19.92 56
CMP50S 1.3 1.32 5.2 7.0 1.7 1.7 0.42 0.48 3.1 4.3 37 11.6 62
CMP50M 2.4 2.3 10.3 13.1 3.5 3.35 0.67 0.73 4.3 3.1 20.5 5.29 66
CMP50L 3.3 3.15 15.4 19.5 4.8 4.6 0.92 0.99 4.3 3.1 14.6 3.56 68
CMP63S 2.9 3.05 11.1 18.3 4 4.2 1.15 1.49 7 9.3 18.3 3.34 64
CMP63M 5.3 5.4 21.4 32.4 7.5 7.6 1.92 2.26 9.3 7 9.8 1.49 67
CMP63L 7.1 6.9 30.4 41.4 10.3 10 2.69 3.03 9.3 7 7.2 1.07 71
Selected motor:CMP63MMpk = 21.4 NmJmot = 1.92 × 10-4 kgm2
5.8.3 Determining the inertia ratio "k"
J mv
nJ
J kg
m
s
ext G
ext
= · · +
= · ·
91 2
91 2 50
2
3565 0651
2
.
.
.m
max
max
iin
.
.
+ ·
= ·
-
-
2
4 2
4 2
0 03 10
14 38125 10
kgm
J kgmext
( )
( )
( )2
Jext is thus in relation to the motor shaft.
kJ
J
kkgm
kgm
k
ext
Motor
=
=·
·
=
-
-
14 38125 10
1 92 10
7 49
4 2
4 2
.
.
.
Selection condition:k ≤ 157.49 ≤ 15Condition is fulfilled.
1938
1212
/EN
– 0
3/20
15
5Project planningProject planning example
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 65
5.8.4 Intrinsic acceleration or deceleration of motor in sections 1 and 3
M J Jn
t
M kgm k
Eigen G Mot
Eigen
= +( ) ··
= · + ·- -
max
.
. .
9 55
0 03 10 1 92 104 2 4 ggm
s
M NmEigen
2
3565 0651
9 55 0 2
0 3639
( ) ··
=
.min
. .
.
-10
4
5.8.5 Maximum motor torques in sections 1 and 3
Travel section 1
M M M
M Nm Nm
M Nm
t e Eigen
t
t
1 1
1
1
3 036 0 3639
3 3999
= +
= +
=
max
. .
.
Travel section 2
M M M
M Nm Nm
M Nm
t e Eigen
t
t
3 3
3
3
2 357 0 3639
1 9931
= +
= - +
= -
max
. .
.
5.8.6 Effective motor torque
MtM t M t
MNm s Nm
eff
z
n n
eff
= · + + ·( )
=( ) · +
1
3 399 0 2 0 0294
1
2
1
2
2
...
. . .(( ) · + -( ) ·
=
2
0 8 1 9931 0 2
3
1 0174
. . .
.
s Nm s
s
M Nmeff
2
5.8.7 Thermal effective motor speed
nn t n t
t
n
eff
n n
z
eff
=· + + ·
=
1
1 5
1
1 5
1 5
3565 0651
2
. .
.
...
.min
· + · +
1 5
1 5
0 2 3565 0651
0.8s
3565 0651
2
.
.
. .min
.min
s ·
=
1 5
1 5
0 2
3
1646 31
.
.
.
.min
s
s
neff
1938
1212
/EN
– 0
3/20
15
5
5 Project planningProject planning example
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10066
5.8.8 Determining the dynamic and thermal motor operating points• The thermal operating point must be below or exactly on the thermal limit charac-
teristic curve:
Meff ≤ MNom
• The dynamic limit torque must be checked:
Mmax Mot ≤ Mpk
0
5
10
15
20
0 1000 2000 3000 4000 5000 6000 7000
M [N
m]
n [1/min]
360V
400V
460V
500V
DC 750V
M S1
M S1 /VR
M S1, BK
Mt1
Meff
Key:
M S1 M S1 thermal (derating)
DC 750 V controlled on DC 750 V constant
500 V 500 V line voltage, non-controlled
460 V 460 V line voltage, non-controlled
400 V 400 V line voltage, non-controlled
360 V 360 V line voltage, non-controlled
Definition:• M = Maximum dynamic torque for a maximum line voltage on the inverter of 360 V,
400 V, 460 V or 500 V• M S1 (derating) = thermal limit characteristic curve in S1 – 100% operation
1938
1212
/EN
– 0
3/20
15
5Project planningProject planning example
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 67
5.8.9 Inverter assignmentRefer to the inverter assignments of CMP servomotors to MOVIDRIVE® andMOVIAXIS® in chapter Technical data of the motors (→ 2 71).
5.8.10 Calculating the braking resistorThe selection of the braking resistor depends, among other factors, on which brakingresistor may be connected to the respective inverter.If you use a MOVIDRIVE® inverter or MOVIAXIS® servo inverter, refer to the respec-tive system manual for detailed information.You can also determine the corresponding braking resistor using the SEW Work-bench.
Peak braking power in travel section 3
PM n
P
Nm
P
Br pk
tn tn Last
Br pk
B
_
_
.min
.
=· ·
=
· ·
η
9550
1 9931 35651
0 9
9550
rr pk kW_
.= 0 6696
Mean braking power in travel section 3
PM n
P
Nm
P
Br
tn tn Last
Br
.min
.
=· ·
=
· ·
η
9550
1 9931
35651
20 9
9550
BBrkW.= 0 3348
4796909195
Effective braking power
PP t
t
PkW s
s
P kW
Br effBr
z
Br eff
Br eff
_
_
_
. .
.
=
⋅
=
⋅
=
3
0 3348 0 2
3
0 0223
1938
1212
/EN
– 0
3/20
15
5
5 Project planningOperation on inverter
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10068
5.9 Operation on inverterThe following products are available from SEW‑EURODRIVE for operating the syn-chronous servomotors on inverters:• MOVIDRIVE® MDX60B/61B drive inverter• MOVIAXIS® MX multi-axis servo inverter
MOVIDRIVE
MDX60/61 B
® MOVIAXIS MX®
4800297995
1938
1212
/EN
– 0
3/20
15
5Project planningOperation on inverter
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 69
5.9.1 Product characteristicsThe following table lists the most important product characteristics for the various in-verter series. You can choose the inverter series matching your application based onthese product characteristics.
Product characteristics MOVIDRIVE® MDX60/61B MOVIAXIS® MX
Voltage range 3 × AC 380 – 500 V
3 × 200 – 240 V AC (limited powerrange)
3 × AC 380 – 500 V
Input power range 0.55 – 160 kW 10 – 75 kW
Rated current range of axis mod-ules
4 – 250 A 2 – 133 A
Overload capacity 150% IN1) briefly and 125% IN per-
manently during operation withoutoverload.
250% for max. 1 second
4Q capable Yes, with integrated brake chopper as standard.
Integrated line filter According to limit value class A forsizes 0, 1, and 2
Yes, according to limit class A.
TF input Yes
Control modes V/f or voltage-controlled flux vectorcontrol (VFC), with speed feed-back speed control and current-
controlled flux vector control(CFC).
Current-controlled flux vector con-trol
System resolution 4096 65536
Speed feedback Option Integrated in basic unit
Integrated positioning and se-quence control system
Standard
Serial interfaces System bus (SBus)
RS-485
CAN based system bus SBus, op-tional EtherCAT® compatible sys-
tem bus SBusplus
Fieldbus interfaces Optional PROFIBUS-DP, INTER-BUS, INTERBUS FOC, CANopen,
DeviceNetTM, Ethernet
Optional PROFIBUS-DP,EtherCAT®
Technology options Input/output card
Synchronous operation
Absolute encoder card
IEC-61131 control
Synchronous operation, electronicgear, touch probe, event control,electronic cam, virtual encoder,
single-axis positioning
Max. speed 6000 rpm 10000 rpm
STO – Safe Torque Off Yes Option
Approvals UL and cUL approval, C-tick1) Only for MOVIDRIVE® MDX60/61B: The temporary overload capacity of size 0 units (0005 to 0014) is 200% IN
1938
1212
/EN
– 0
3/20
15
5
5 Project planningMaximum speeds of CMP and CMPZ motors
Catalog – CMP40 – CMP112, CMPZ71 – CMPZ10070
5.10 Maximum speeds of CMP and CMPZ motorsThe following maximum speeds, which are permitted mechanically, apply to the mo-tors:
Motor type Maximum speed in rpm
CMP40 – 63/BK
7200CMP40 – 80
CMPZ71 – 80
CMP100, CMPZ100 5400
CMP112 5200
CMP40 – 71 /BP 6000
CMP80 /BP 5500
CMP100 /BP 5400
CMP112 /BY 4500
CMPZ71 /BY 6000
CMPZ80 – 100 /BY 4500
1938
1212
/EN
– 0
3/20
15