100
The Power of Excellence Marine Catalogue Marine Katalog Catalogue Marine Catálogo Marino Katalog Aplikacji Morskich Catalog Aplicaţii Maritime Katalog Nautičkog Programa Каталог по морскому транспорту 2014 PP4029 Rev: 1 (2014)

Catalog Aplicaţii Maritime Katalog Nautičkog Programa ...€¦ · Cummins 8SC3068V, 110-431 1501935, 3640732 8SC3169U 24V 100A INSULATED YES CW N-type J-180 mount B+, B-, WL, ExC,

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • The Power of Excellence

    Marine CatalogueMarine KatalogCatalogue MarineCatálogo MarinoKatalog Aplikacji MorskichCatalog Aplicaţii MaritimeKatalog Nautičkog ProgramaКаталог по морскому транспорту

    2014

    PP40

    29Re

    v: 1 (

    2014

    )

  • © 2014 Prestolite Electric Ltd www.prestolite.com

    OUR COMPANYPrestolite is a rapidly expanding global company with manufacturing and distribution in North America, Europe and Asia. Having research and development facilities in each of these locations, the company combines the engineering know-how and manufacturing expertise of Lucas CAV, Leece-Neville, Butec and Motorola, to produce the best starters and alternators range in the market.

    OUR PRODUCTSWe offer a complete range of Heavy, Medium and Light Duty starters and alternators covering all major European Truck, Car and Van applications as well as comprehensive Bus & Coach, Off-Highway, Agricultural, Marine and Industrial application coverage. Look out for our new Refrigeration Equipment and Marine catalogues coming soon!

    OUR UNIQUE OFFERRemember that the vast majority of a range comes to you BRAND NEW. Of course this offers you OE quality levels, no availability problems due to core shortages but also the advantage of NO CORE SURCHARGES! How many times have you sold an alternator or starter only to have your profit wiped out because your supplier won’t accept your core? With Prestolite you can simply sell and forget.

    OUR BRANDSEffective from mid 2007 you would have seen that all of our products are dual branded ‘Prestolite’ and ‘Leece-Neville’. We think it’s important that our customers are able to make the link between these two great brands and it’s a reminder that all ‘Leece-Neville’ products are available from Prestolite – and vice versa!

    The Power of Excellence

  • The Power of Excellence

    © 2014 Prestolite Electric Ltd www.prestolite.com

    a division of Prestolite Electric Inc.

    Prestolite Electric Ltd - Heavy Duty Systems

    Unit 48The Metropolitan Park

    12-16 Bristol Road, Greenford

    Middlesex, UB6 8UP,

    United Kingdom

    Tel: +44 (0) 20 8231 1137

    Fax +44 (0) 20 8575 9575

    Prestolite Electric Ltd. Registered in England No. 1

    189048

    www.prestolite.com

    2014 Marine Catalogue

    Dear CustomerWelcome to the new addt

    ion to our catalgoue range, the 2014 Marine Catalo

    gue for Prestolite Electric

    products.

    Included in this catalogue are popular alternators a

    nd starter motors used on various marine applicatio

    ns,

    ranging from canal barges to life saving vessels.

    Also included is an Auxiliary equipment section, con

    taining regulators, solenoids and external regulatio

    n

    conversion kits.

    We strive to serve you better with this catalogue, a

    nd you opinion matters to us. If you have any

    suggestions on how we can further improve the inf

    ormation we give you, we’d be delighted to hear fro

    m

    you, contact us on [email protected]

    Thanks for your continued support.

    Ferenc Gemesi

    Sales Director – Europe, Asia, Africa

    Prestolite Electric Ltd

    (LH0029v3_02/14)

  • The Power of Excellence

    © 2014 Prestolite Electric Ltd www.prestolite.com

  • The Power of Excellence

    © 2014 Prestolite Electric Ltd www.prestolite.com

    Catalogue Ref No: PP4029Issue no: 1 (03/14)

    Table of Contents

    A How to use this Catalogue ......................................... A-1

    A Glossary of Alternator Terms ...................................... A-2

    A Alternator Wiring Diagrams ......................................... A-4

    A Alternator Function ..................................................... A-7

    A Alternator Troubleshooting Guide ............................... A-7

    A Glossary of Starter Motor Terms ................................ A-8

    A Starter Motor Wiring Diagram .................................. A-9

    A Starter Motor Function ............................................. A-11

    A Starter Motor Troubleshooting Guide ......................... A-11

    1 Alternator Guide .......................................................... 1

    2 Starter Motor Guide ..................................................... 21

    3 Auxiliary Equipment Guide .......................................... 37

    4 Cross Reference Guide ............................................... 45

    SECTION TITLE PAGE

    DISCLAIMERWhile every care has been taken in compiling the information in this document, Prestolite / Leece-Neville cannot accept legal liability for any inaccuracies, omissions, or consequential damage resulting there from. Prestolite / Leece-Neville has an extensive design and development team which may alter product specification. Prestolite / Leece-Neville reserves the right to alter specifications without notice and whenever necessary to endure optimum performance from its product range.

  • The Power of Excellence

    © 2014 Prestolite Electric Ltd www.prestolite.com

    How to use this Catalogue

    SECTION AThis section gives a basic understanding of the operation of the Alternator and Starter Motor within the Marine enviroment, and includes Alternator and Starter Motor function, general wiring diagrams and a Troubleshooting guide.If you have any queries that are not covered by this guide, please contact the Technical Helpline on +44 (0) 20 8231 1137.

    A-1

    MARINE PRODUCT GUIDE 2014ALTERNATORS

    Alte

    rnat

    orG

    uide

    www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113714 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No. OUTPUT POLARITYVOLT

    ADJUSTROTATION

    P / N TYPE FEATURES APPLICATION

    8SC3157V 24V 175A INSULATED YES CW N-type J-180 mount

    B+, B-, WL, ExC, AC

    V adjust 26.8V - 29.5V

    7/8” shaft

    No pulley supplied

    API MarineCaterpillar, CumminsMTU, Sabre8SC3009ZA, 110-258200833001117, 30883203629351, 2687423520958

    8SC3160V 24V 150A INSULATED YES CW N-type J-180 mount

    B+, B-, WL, ExC, AC

    V adjust 26.8V - 29.5V

    7/8” shaft

    No pulley supplied

    CaterpillarCummins8SC3068V, 110-4311501935, 3640732

    8SC3169U 24V 100A INSULATED YES CW N-type J-180 mount

    B+, B-, WL, ExC, AC

    V adjust 26.8V - 29.5V

    7/8” shaft

    No pulley supplied

    Various MarinePerkinsVolvo8SC3015U, 110-302OE52360562612

    A0012303JB 24V 45A INSULATED NO BI-DIR N-type J-180 mount

    B+, B-, AC

    7/8” shaft

    No pulley supplied

    Corrosion protected

    Volvo PentaCaterpillarCummins2303JB0R2698, 0R5217, 3N27023N2706, 3T6352, 3Y66915N5692, 6N5217, 6N92949G8255111640, 3015516, 3604676Rx3675126Rx

    A0014727JB 24V 140A INSULATED YES CW N-type J-180 mount

    B+, B-, ExC, AC

    V adjust 26.0V - 32.0V

    7/8” shaft

    No pulley supplied

    Various MarineVolvo4727JBLN4727JB

    A0014740JB 24V 200A GROUNDED NO CW N-type J-180 mount

    B+, B-, AC

    7/8” shaft

    No pulley supplied

    Various Marine4740JB

    PrestolitePart no.

    Voltage

    Alternator images

    Application / Cross reference

    OutputCurrent

    Insulated or Earth return (Grounded)

    Adjustable voltage

    Direction of Rotation

    P or N Type Regulation

    Product features:Mounting typeTerminationsVoltage set pointShaft sizePulley infoAddtional info

    MARINE PRODUCT GUIDE 2014STARTER MOTORS

    www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113730

    Sta

    rter

    Mot

    orG

    uide

    Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)

    PAR(ENG) FEATURES APPLICATION

    M105R3509SE 24V 7.5kW CW INSULATED 12t 46.7(8/10 DP)47.5

    (66.5)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting & relay

    Cummins3102767, 39774285254108, 52564155284108M009T82671M009T82672

    M105R3510SE 24V 7.5kW CW GROUNDED 10t 40(8/10 DP)47.5

    (66.5)SAE1 (offset) mounting

    B+, B- (Earthed), IGN

    Rotatable mounting & relay

    Cummins3675116, 3965282384011001503675116Rx

    M105R3513SE 24V 7.5kW CW INSULATED 12t 46.7(8/10 DP)47.5

    (66.5)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting & relay

    Volvo Penta3801289, 38038383586798M009T82179M009T84079

    M105R3514SE 24V 7.5kW CW INSULATED 12t 44.1(M3)47.5

    (66.5)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting & relay

    Mercedes-BenzInsulated version of 0001330011, 00013300200001372005, 00013720060986018370, 09860208800986022980M009T80471, M009T80472M009T80473, M009T83671M009T84771

    M110R2601SE 12V 7.0kW CW INSULATED 12t 44.1(M3)47.5

    (66.5)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting & relay

    Corrosion protected

    Mercedes-BenzM009T70379M009T7117919011505, 190115148200084, 82004348300013

    M110R2602SE 12V 7.0kW CW INSULATED 12t 46.7(8/10 DP)47.5

    (66.5)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting & relay

    Corrosion protected

    Volvo21019456, 21019460M9T71179MK2078MK2079VV2079

    PrestolitePart no.

    Voltage

    Starter Motorimages

    OutputPower

    Rotation

    Product features:Mounting typeTerminationsAdditional info

    No. of teeth

    Pinion at rest(Full travel)

    Pinion diameter(Pinion module)

    Insulated or Earth return (Grounded)

    Application / Cross reference

  • The Power of Excellence

    © 2014 Prestolite Electric Ltd www.prestolite.com

    Glossary of Alternator Terms

    Earth return (ER) / Grounded (G) alternators may only be fitted with a B+ (battery positive) terminal. The negative part of the electrical circuit is normally completed through the body of alternator to the vehicle, ie earthed / grounded. Also refered to as ground return. On certain vehicles a B- stud is fitted to the alternator. This is connected to the body of the alternator and must be connected to the negative earth lead where fitted.

    Insulated return (IR) / Insulated ground (IG) alternator have B+ (battery positive) and B- (battery negative) terminals, ie the battery leads at the alternator are insulated from the alternator frame, ie insulated return.

    B+ terminal is the battery positive connection on the alternator.

    B- terminal is the battery negative terminal on the alternator.

    WL is the warning lamp terminal. (L when smartreg is used.)

    W or ~ or AC is the phase terminal, used for tachometer

    DFM terminal communicates with the vehicle ECU and controls alternator output depending on load and system conditions.

    F- is field isolation terminal. If field isolation is not required the F- must be connected to the B- terminal.

    S is the sense lead / terminal. This is normally used where the voltage drop across battery leads are expected to be significant, ie long battery cable runs, where multiple battery banks and load splitters are used. This terminal monitors the voltage at the point of termination not the alternator terminals, and regulated alternator performance accordingly. This terminal is normally connected directly to the positive terminal of the charging system battery.

    Alternator rotation. Alternator rotation is determined by the fan design. By design the alternator is bi-directional and can operate in either CW or CCW direction. Straight vain fans are bi-directional, see fig.1.Curved vain fans are direction specific, and a rotation direction is indicated on the fan, see fig.2. Directional fan design generally provide more efficient cooling of alternator.

    Internal fan alternators are rotation specific, due to the fans being permanently attached internally to the rotor.The direction of rotation on internal fan alternators cannot be changed.Consult the drawing or Technical Helpline for specific part number rotational direction.

    Note: Directional rotation when looking at front of the alternator.

    Fig.1 Fig.2

    A-2

  • The Power of Excellence

    © 2014 Prestolite Electric Ltd www.prestolite.com

    Glossary of Alternator Termscontinued...

    Mounting configurations. Various options are available, see fig.3 - fig.6

    Dual foot mount onmain mounting bracket, and single mounting on adjusted bracket.

    Spool mount onmain mounting bracket, spool size from 25mm - 80 mmand single mounting on adjuster bracket.

    Cradle mountThe alternator is mounted by clamping it around the alternator body.

    Pad mount4 Mounting point as shown.T-mount is similar to pad mount, but with only 3 mounting point.(2 on drive end and 1 on rear end)

    Fig.3 Fig.4

    Fig.5 Fig.6

    A-3

  • The Power of Excellence

    © 2014 Prestolite Electric Ltd www.prestolite.com

    Alternator Wiring Diagrams

    The wiring diagrams shown below are typical and for reference only. For specific wiring diagrams or information, please contact the Technical Helpline on +44 (0) 20 8231 1137.

    EARTH RETURN The negative circuit is supplied through the vehicle chassis and the alternator frame.

    INSULATED RETURN The negative circuit is isolated from alternator frame and vehicle chassis.

    Fig.7

    Fig.8

    A-4

  • The Power of Excellence

    © 2014 Prestolite Electric Ltd www.prestolite.com

    Alternator Wiring Diagramscontinued...

    FIELD ISOLATION This option is supplied with a F- terminal, for use with battery / field isolator switch.

    Fig.9

    Battery

    +-

    W (Tacho)

    L (Lamp)

    DFM (Field monitor)

    S (Sense)

    15 (Ignition)

    Secondary B+

    NCB2 TYPE This is an earth return alternator.The vehicle harness plugs directly into the regulator connection. The regulator may interact with the vehicle ECU. These regulators are not interchangeable as some functions vary depending on application. Ensure the correct regulator / alternator is specified.

    Fig.10

    A-5

  • The Power of Excellence

    © 2014 Prestolite Electric Ltd www.prestolite.com

    Multiple applications are common placed where high current demand is required.It is important that the regulated voltage of the alternators used are matched, failure to do so would cause one of the alternators to shutdown. In addition it also important that the lenght of cables for the two alternators be kept the same to ensure that the voltage drops in the lines are identical (or as close as possible). The voltage drops must not exceed 1.0V.

    Alternator Wiring Diagrams

    o o

    Battery+-

    WL WL

    To tacho

    o oIgnitionIgnition

    TWIN APPLICATION Two (or more) alternators paired to deliver high current output. Fig.11

    External regulators / Battery management systems.Many vessels use complex battery management systems to charge multiple battery banks. This is done by linking into the alternator field brush to control the field current. For wiring instructions, please consult with battery management system supplier.External regulation conversion kits are available for the 8LHA, 8LHP, BLD, BLP, LBA, LBP, MDA, MDA alternators, please see Auxiliary Component section.

    Not all alternators are suitable for use with split charging systems. Split charging systems can prevent the alternator from sensing battery voltage or give a fasle battery voltage reading. Ideally an alternator with a sense (S) terminal must be used. See fig.8.

    Please note that external regulation systems and battery management systems might operate the alternator outside of its intended design parameters and could invalidate warranty.

    A-6

  • The Power of Excellence

    © 2014 Prestolite Electric Ltd www.prestolite.com

    Alternator Function

    The alternator essentially consists of 3 components; the rotor / stator assy, the rectifier and the regulator.

    The rotor and stator assembly utilised basic physics to generate electricity by rotating an electromagnetic field (rotor) within a series of windings (stator). This produces a 3 phase alternating current (AC) output from the stator.

    The AC output is not suitable for DC system. The rectifier utilised a series of diodes to convert the original AC output to a direct current (DC) output, which is supplied to the vehicle loads and batteries.

    The regulator controls the output of the alternator by increasing and decreasing the magnetic field of the rotor as required.

    The alternator must be able to supply current to all required loads and have sufficient capacity to charge the vehicle batteries.

    Most vehicles have some kind of warning light function that indicates when the alternator is not functioning as expected. This warning light will be illuminated when the ignition is switched on, but engine not started.Once the engine has been started and is idling the warning light go out. This warning light circuit also serves as an excitation for the alternator, supplying approx 2.0-2.8W. The alternator will not charge if the warning light is not connected.

    For alternator wiring details refer to Fig.7 - to Fig.11. These illustrations are for reference only, please contact the Technical Helpline on +44 (0) 20 231 1137 for specific wiring information.

    Problem Possible cause Action

    No warning light when switched on

    Flat batteryCheck battery, charge in accordance with battery manufacturer’s specification if required.

    Blown warning light bulb or fuse Check warning light bulb or fuse.

    Poor / incorrect connections Check wiring and connections.

    Warning light does not go out when engine idling

    Poor / incorrect connections Check wiring and connections.

    Warning light shorted to earth Check wiring and connections.

    Excessive voltage drop in ignition circuit

    Check wiring and connections.

    Faulty rectifier Check rectifier circuit and diodes.

    Faulty regulator or alternator Remove and test regulator and alternator.

    Low outputSlipping drive Check Pulley, belts or coupling.

    Faulty regulator or alternator Remove and test regulator and alternator.

    Flickering warning light

    Slipping drive Check Pulley, belts or coupling.

    Volt drop in sensing line Check wiring and connections.

    Faulty regulator or alternator Remove and test regulator and alternator.

    Battery overcharging, high alternator output voltage

    Faulty regulator Remove and test regulator.

    Alternator Troubleshooting Guide

    A-7

  • The Power of Excellence

    © 2014 Prestolite Electric Ltd www.prestolite.com

    Glossary of Starter Motor Terms

    Earth return (ER) starter motors will only be fitted with a B+ (battery positive) terminal. The negative part of the electrical circuit is completed through the body of starter motor and the vehicle chassis.

    Insulated return (IR) starter motors have B+ (battery positive) and B- (battery negative) terminals, ie the battery leads at the alternator are insulated from the vehicle chassis.

    B- terminal is the battery negative terminal on the alternator or starter motor.

    B+ / Terminal 30 is the battery positive connection terminal on starter motor, normally found on solenoid.

    SW / Terminal 50 is the positive feed connection to the solenoid.

    Terminal 15a is a cold start terminal.

    Rotation is generally in a clockwise (CW) direction, when looking at the front of the starter motor, however there are counter clockwise CCW applications.

    Pinion at rest (PAR) position is the meassured distance between the mounting flange and the front face of pinion when the starter is not energised. (See Fig. 9)

    Pinion full travel position is the measured distance between the mounting flange and the front face of the pinion when the starter motor is energised. (See Fig.9)

    Fig.12 Fig.13

    Fig.14

    CW CCW

    A-8

  • The Power of Excellence

    © 2014 Prestolite Electric Ltd www.prestolite.com

    Glossary of Starter Motor Termscontinued...

    Solenoid / Switch is the part of the starter that activates the engagement / disengagement of the pinion/drive to the vehicle ringgear/flywheel, and also connects the battery to the motor via contact switch.

    Mounting configurations. Several options are available, the most common are SAE1 and SAE3.See fig.15 & fig.16.

    Starter drive is the mechanism linking the starter rotational force and the vehicle engine, via ring gear/flywheel.This incorporates an overrun device to protect the motor in the event that the starter is not released when the engine has starter.

    The pinion is the geared component on the drive that interfaces with the ring gear / flywheel.

    The wiring diagrams shown below are typical and for reference only. For specific wiring diagrams or information, please contact the Technical Helpline on +44 (0) 20 8231 1137

    The fitment of a Starter Lockout unit is recommended to prevent energising of starter motor whilst engine is running.

    SAE1The 3 mounting holes are on a PCD of 127mm, spaced at 90°

    SAE3The 3 mounting holes are on a PCD of 146mm, equi-spaced at 120°

    Fig.15 Fig.16

    Starter Motor Wiring Diagrams

    Fig.17

    EARTH RETURN The negative circuit is supplied through the vehicle chassis and the starter motor frame.

    A-9

  • The Power of Excellence

    © 2014 Prestolite Electric Ltd www.prestolite.com

    Starter Motor Wiring Diagramscontinued...

    AUXILIARY SOLENOID Used on gear reduction starters to limit current draw during soft start operation.

    INSULATED RETURN The negative circuit is isolated from starter motor frame and vehicle chassis.

    Fig.18

    Fig.19

    NOTE: Do not disconnect or bypass the control relay (if fitted) on the starter motor.

    A-10

  • The Power of Excellence

    © 2014 Prestolite Electric Ltd www.prestolite.com

    Starter motor FunctionThe basic components of the starter motor is the solenoid (switch), the motor, the shift assembly and the drive assembly.

    When the circuit is energised, via the start button, the solenoid is activated into 1st stage contact, which engages thelinkage system in the shift assembly and in turn moves the drive towards the ringgear. At this point a small current will flow through the motor causing a slow rotation of the motor and drive, this is to allow for the pinion to engage the ringgear correctly. Once the pinion has engaged the ringgear, the solenoid 2nd contact will be activated and full current will be supplied to the motor, causing the motor to rotate at full speed and torque, cranking the engine via the drive and ringgear.

    Once the engine has started and the engine speed is higher than that of the starter motor the overrunning protection function of the drive will prevent the engine accelerating the starter motor. As soon as the engine has started the driver / operator should release the starter button.Please note that the over-run clutch protection function will be damaged by wreckless & prolonged over-cranking.

    Gear-reduction starter motors are becoming increasingly popular due to compact design. These starters operatare in the same manner, but is fitted with a small gearbox between the motor and the shift / drive assembly.

    For starter motor wiring details refer to Fig.17, Fig.18 and Fig.18. These illustrations are for reference only, please contact the Technical Helpline on +44 (0) 20 8231 1137 for specific wiring information.

    Starter motor Troubleshooting GuideProblem Possible cause Action

    Starter does not engage

    Flat batteryCheck battery, charge in accordance with battery manufacturer’s specification if required.

    Poor / incorrect connections Check wiring and connections.

    Faulty ignition or start buttonCheck battery voltage is available at the starter motor solenoid terminals when ignition / buton operated.

    Faulty solenoid / auxiliary solenoid Test operation of the solenoid / auxiliary solenoid.

    Faulty starter Remove and rectify.

    Starter engages but does not crank the engine

    Flat batteryCheck battery, charge in accordance with battery manufacturer’s specification if required.

    Poor / incorrect connections Check wiring and connections.

    Excessive volt drop in main cablesCheck voltage drop by measuring voltage between starter terminals and battery terminals. Also, check earth circuit when ignition / button is operated.

    Incorrect starter timing Remove and rectify.

    Faulty starter Remove and rectify.

    Starter engages but cranks slowly

    Flat batteryCheck battery, charge in accordance with battery manufacturer’s specification if required.

    Poor / incorrect connections Check wiring and connections.

    Excessive volt drop in main cablesCheck voltage drop by measuring voltage between starter terminals and battery terminals. Also, check earth circuit when ignition / button is operated.

    Faulty solenoid Remove and replace.

    Faulty starter Remove and rectify.

    Starter spins against flywheel

    Spacer or mounting flange unneccessary Check if spacer is required and discard if unnecassary

    Incorrect starter timing Remove and rectify.

    Faulty starter Remove and rectify.

    A-11

  • The Power of Excellence

    © 2014 Prestolite Electric Ltd www.prestolite.com

    Notes:

  • The Power of Excellence

    © 2014 Prestolite Electric Ltd www.prestolite.com

    Notes:

  • Alt

    ern

    Ato

    rs

    Gen

    erA

    tor

    enA

    lter

    nA

    teu

    rs

    Alt

    ern

    Ad

    or

    es

    Alt

    ern

    Ato

    ri

    Alt

    ern

    Ato

    ry

    Alt

    ern

    Ato

    Ar

    eГе

    нер

    ато

    ры

  • MARINE PRODUCT GUIDE 2014ALTERNATORS

    Alte

    rnat

    orG

    uide

    www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 11372 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No. OUTPUT POLARITYVOLTAGEADJUST

    ROTATIONP / N TYPE FEATURES APPLICATION

    858882 24V 55A GROUNDED NO CW N-type 80mm Spool mount

    Earth return (B- stud)

    B+, B-, WL, AC

    17mm shaft

    No pulley supplied

    Scania0120469569, 01204696430120469763, 01204698070120469900, 01204699590120469960, 0986032720 19025102, DRA2720CA155IR, CA227IR, CA749IR LRB104

    860053 24V 75A INSULATED NO CW N-type J-180 mount

    B+, B-, WL, AC

    7/8” shaft

    No puley supplied

    Can use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S(TSB-1112)

    Various MarineCummins8598663284848DRA3596

    860141 24V 27A GROUNDED NO CW N-type Swung mount

    B+, B-, WL

    17mm shaft

    No pulley supplied

    Fiat, Iveco0120489410/2/3, 0120489612, 0120489638/9 0120489661,01204896820120489792/3/40120489795/60986031340, 098603219119025044, DRA1340CA212IR, LRA839, LRB300

    1268110M 12V 75A INSULATED NO CW N-type 3” Spool mount

    B+, B-, WL, S, AC

    Field isolation (F-)

    3/4” shaft

    No pulley supplied

    Corrosion protected

    Various MarineCummins3910565, 3975138

    1268600M 24V 55A INSULATED NO CW N-type 3” Spool mount

    B+, B-, WL, S, AC

    Field isolation (F-)

    3/4” shaft

    No pulley supplied

    Corrosion protected

    Various MarineDorman, Perkins, RNLI702178OD18580D14809

    1268650M 24V 55A INSULATED NO CW N-type 3” Spool mount

    B+, B-, WL, S, AC

    Field isolation (F-)

    3/4” shaft

    No pulley supplied

    Corrosion protected

    Various MarineCummins3910566, 3975139

  • www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137

    MARINE PRODUCT GUIDE 2014 ALTERNATORS

    3

    Alte

    rnat

    orG

    uide

    Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No. OUTPUT POLARITYVOLT

    ADJUSTROTATION

    P / N TYPE FEATURES APPLICATION

    1282030M 24V 240A INSULATED NO BI-DIR N-type Twin lugs

    B+ (x2), B-, WL, AC

    Special build

    30mm shaft

    No pulley supplied

    Corrosion protected

    Various MarineRNLI, VolvoD14849

    1287000 24V 600A GROUNDED NO BI-DIR Swung mount

    B+ (x2), B-, WL, IGN, S, AC, DFM

    Special build

    30mm shaft

    No pulley supplied

    New releaseAB210R type

    20100527 12V 65A GROUNDED NO BI-DIR N-type Swung mount

    B+, WL

    17mm shaft

    4pk, 59mm pulley

    Various Marine0986038401DRA3199JA756IRLRA527

    20110134 12V 70A GROUNDED NO CW N-type 56mm Spool mount

    B+, WL, AC

    17mm shaft

    No pulley supplied

    Various MarineVolvo0120488114, 01204881850120489069, 01204890700120489183, 01204893090986032930, 09860329400986037890DRA2930, CA231IRCA238IR, LRB134

    20110290 12V 70A GROUNDED NO BI-DIR N-type Swung mount

    B+, WL, AC

    Europlug connection

    17mm shaft

    No pulley supplied

    Various MarinePerkins2871A154, 2871A160DRA3667LRB290

    20110293 12V 65A GROUNDED NO CW N-type 56mm Spool mount

    B+, WL, AC

    17mm shaft

    No pulley supplied

    Various Marine0120339512/3, 01203395320120339545, 01204891560120489317, 0120489703/40986030110, 0986033320DRA3445CA522IR, CA734IR, CA915IRLRA621, LRB293

  • MARINE PRODUCT GUIDE 2014ALTERNATORS

    Alte

    rnat

    orG

    uide

    www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 11374 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No. OUTPUT POLARITYVOLT

    ADJUSTROTATION

    P / N TYPE FEATURES APPLICATION

    20130133 1(2V 70A GROUNDED NO CW N-type 56mm Spool mount

    B+, WL, AC

    17mm shaft

    No pulley supplied

    Various MarineDeutz, Iveco, KHD0120300552, 01203395140120339531, 01204897560986030130, 0986031330DRA0130CA340IR, CA745IR, CA76IRLRA584

    20130134 24V 35A GROUNDED NO CW N-type 56mm Spool mount

    B+, WL, AC

    17mm shaft

    No pulley supplied

    Various MarineDeutz, Iveco, KHD0120488153, 01204882340120488283, 01204897310986031320, 0986035910DRA1320, DRA5910CA369IR, CA702IR

    20130177 12V 35A GROUNDED NO CW Swung mount

    B+, B-, WL, AC

    Single V, 72mm pulley

    Yanmar12140077201, 1240807720112817177200, 12827077200LR12015C, LR135105LR135126, LR13521LR13558(B), LR13591

    20130178 12V 51A GROUNDED NO BI-DIR 2” Spool mount

    B+, B-, WL, Exc, S, AC

    17mm shaft

    Single V, 73mm pulley

    Mercruiser, YamahaJA787IR,10140010A000B0431, A000B0471KAC155513, AR150CAAR150DA, AR155CA, M40473TA0B09601

    20130179 12V 65A GROUNDED NO BI-DIR 2” Spool mount

    B+, B-, WL, Exc, S, AC

    17mm shaft

    6pk, 63mm pulley

    MercruiserJA1169IR,A000B0331, AC155603AC155616, AC165610AC165616/7, AR150AAAR150AR, AR150BAM50924, M59207, 8171191/2805884P/T, 807652/3

    20130204 12V 65A GROUNDED NO BI-DIR 2” Spool mount

    B+, B-, WL, Exc, S, AC

    17mm shaft

    Single V, 73mm pulley

    Various MarinePleasurecraftVolvoAC155614, AC165618M56750, 3856600RA0970063857813, 3860171, 3856600638575619

  • www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137

    MARINE PRODUCT GUIDE 2014 ALTERNATORS

    5

    Alte

    rnat

    orG

    uide

    Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No. OUTPUT POLARITYVOLT

    ADJUSTROTATION

    P / N TYPE FEATURES APPLICATION

    20130207 12V 65A GROUNDED NO CW N-type Swung mount

    B+, B-, WL

    17mm shaft

    Single V, 90mm pulley

    Various MarineMermaid Marine Engines0986030970, 09860332300986033880, 0986035630/10986036230

    20130211 24V 45A GROUNDED NO CW N-type 2” Spool mount

    B+, WL, AC

    17mm shaft

    No pulley supplied

    Cummins3020678, 32843913284392, 39112473920678(Rx)0120488206, 01204882940120489071, 0120489481

    20150113 12V 90A INSULATED NO BI-DIR N-type 2” Spool mount

    B+, B-, WL, AC

    17mm shaft

    Single V, 64mm pulley

    Corrosion protected

    Volvo Penta11203416, AAK4352, IA120210127

    20150114 24V 80A INSULATED NO BI-DIR* N-type 2” Spool mount

    B+, B-, WL, AC

    17mm shaft

    No fan or pulley supplied

    Corrosion protected

    API MarineVolvo Penta

    20150115 24V 65A INSULATED NO BI-DIR* N-type 2 Lug mount

    B+, B-, WL, AC

    17mm shaft

    No fan or pulley supplied

    Corrosion protected

    Various MarineIveco Marine engineScania0120468132, 098604407019025115571440, 1358638, 1397038

    20150116 24V 80A INSULATED NO BI-DIR* N-type 80mm Spool mount

    B+, B-, WL, AC

    17mm shaft

    No fan or pulley supplied

    Corrosion protected

    Various MarineCumminsMercedes / MAN engine3283780A007154810201177464

  • MARINE PRODUCT GUIDE 2014ALTERNATORS

    Alte

    rnat

    orG

    uide

    www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 11376 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No. OUTPUT POLARITYVOLT

    ADJUSTROTATION

    P / N TYPE FEATURES APPLICATION

    47020067 12v 70A INSULATED NO CW Swung mount

    B+, B-, WL, AC

    17mm shaft

    No pulley supplied

    Corrosion protected

    90A version = 66021535

    24V/60A version = 66021532

    API MarineLister PetterSabre Marine20024, 362023442871A60240082LRA0117866021587

    47020069 12v 70A INSULATED NO CW Swung mount

    B+, B-, WL, AC

    17mm shaft

    No pulley supplied

    Corrosion protected

    Various MarineLister PetterSabre Marine 3620234966021588

    66021126M 12V 60A INSULATED NO BI-DIR N-type 2 Lug mount

    B+, B-, WL, AC

    17mm shaft

    Single V, 65mm pulley

    90A version = 66021590M

    Various MarineSole DieselCA1550IRNAB900MPBNAM10013817100

    66021151M 12V 70A INSULATED NO BI-DIR N-type 2” Spool mount

    B+, B-, WL, AC

    17mm shaft

    Single V, 64mm pulley

    Corrosion protected

    90A version = 20150113

    API MarineVolvo Penta

    66021151MS 12v 70A INSULATED NO CW N-type 2” Spool mount

    B+, B-, WL, S, AC

    17mm shaft

    No pulley supplied

    Volvo Penta436378, 436638, 436676439067, 439181, 439185518039, 2541191, 25414512541827, 2927120A13N186M, A13N2858720195, 3803146438032603

    66021153B 12V 70A GROUNDED NO BI-DIR N-type 56mm Spool mount

    B+, WL, AC

    17mm shaft

    Single V, 64mm pulley

    Various MarineNAB902, NAB904CA1467IR, CA1479IR

  • www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137

    MARINE PRODUCT GUIDE 2014 ALTERNATORS

    7

    Alte

    rnat

    orG

    uide

    Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No. OUTPUT POLARITYVOLT

    ADJUSTROTATION

    P / N TYPE FEATURES APPLICATION

    66021414 12V 70A GROUNDED NO CW N-type 56mm Spool mount

    B+, WL, AC

    17mm shaft

    Single V, 65mm pulley

    Various Marine0986030870, 09860308800986030890, 0986034650/1LRA207, LRA313, LRA346LRA786, LRA819, LRA886LRB131

    66021491 24V 55A INSULATED NO BI-DIR N-type 3” Spool mount

    B+, B-, WL, AC

    Field isolation (F-)

    3/4” shaft

    8pk, 82mm pulley

    Various Marine108026, 108275, 858948859444, 859876, 858948ZA302441LNA40241, LNA40249

    66021507 24V 55A INSULATED NO BI-DIR N-type 3” Spool mount

    B+, B-, WL, AC

    Field isolation (F-)

    3/4” shaft

    No pulley supplied

    Various MarineCumminsPerkins550117, 3250087, 32567593279007, 3964745 3256759Rx 2871A682880624Z, 880626Z, 880627Z880628Z, 880629Z, 880648Z

    66021532 24V 60A INSULATED NO BI-DIR N-type 2 Lug mount

    B+, B-, WL, AC

    17mm shaft

    Single V, 80mm pulley

    Corrosion protected

    12V version = 47020067

    Sabre MarinePerkinsVolvo35362, 192792871A651, 2871C2023976608, 811309747020061, 47020083 47020090, 66021593PBNAM102, PBNAM108

    66021535 12V 90A INSULATED NO BI-DIR N-type 2 Lug mount

    B+, B-, WL, AC

    17mm shaft

    Corrosion protected

    70A version = 47020067

    Lister PetterPerkinsSabre Marine35361, 400822871A145, 2871A1522871A157, 2871A60236202344

    66021543 12V 60A GROUNDED NO BI-DIR Swung mount

    B+, WL, AC

    15mm shaft

    Single V, 68mm pulley

    Various MarinePerkins2871A122, 2871A139LRA278, LRA360, LRA582

  • MARINE PRODUCT GUIDE 2014ALTERNATORS

    Alte

    rnat

    orG

    uide

    www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 11378 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No. OUTPUT POLARITYVOLT

    ADJUSTROTATION

    P / N TYPE FEATURES APPLICATION

    66021583 12V 70A GROUNDED NO CW N-type 27mm Spool mount

    B+, B-, WL, AC

    17mm shaft

    Single V, 80mm pulley

    Aqua CultureLRA2209AR2510K, 9AR2513F9AR2514F, 9AR2553K9AR2556K, 9AR2566K9AR2856K

    66021590M 12V 90A INSULATED NO BI-DIR N-type 2 Lug mount

    B+, B-, WL, AC

    17mm shaft

    Single V, 65mm pulley

    24V version = 66021623M

    Various Marine113152NAB9000M

    66021623M 24V 60A INSULATED NO BI-DIR N-type Swung mount

    B+, B-, WL, AC

    17mm shaft

    Single V, 65mm pulley

    Corrosion protected

    12V version = 66021590M

    Various MarineNAB9001M

    66021626A 24V 55A INSULATED NO BI-DIR N-type 3” Spool mount

    B+, B-, WL, AC

    Field isolation (F-)

    3/4” shaft

    No pulley supplied

    Various Marine702175, 702183, 702184702185, 702186859450Z, A402420, A402426LNA40244, LNA4024566021544GB, 66021616/A

    66021627A 24V 55A INSULATED NO BI-DIR N-type 3” Spool mount

    B+, B-, WL, AC

    Field isolation (F-)

    3/4” shaft

    No pulley supplied

    Various MarineCummins3332215, 3631678, 36347784101372859617, 66021496, LNA40247

    66021636 12V 65A GROUNDED NO BI-DIR N-type Swung mount

    B+, WL, AC

    17mm shaft

    Single V, 72mm pulley

    Various MarineFord,Perkins2871A141, 2871A1472871A148, 2871A1532871A154, 2871A1632871A165, 2871C1042871K148

    W

    AUX

    W

    AUX

  • www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137

    MARINE PRODUCT GUIDE 2014 ALTERNATORS

    9

    Alte

    rnat

    orG

    uide

    Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No. OUTPUT POLARITYVOLT

    ADJUSTROTATION

    P / N TYPE FEATURES APPLICATION

    66021637 12V 65A GROUNDED NO BI-DIR N-type Swung mount

    B+, WL, AC

    17mm shaft

    Single V, 72mm pulley

    Various MarineFord,Perkins9AR2562, 9AR2569 9AR2651D, 9AR26539AR2706G2871A142, 2871A1612871D031, 3907749

    8AR3200G 24V 40A INSULATED NO BI-DIR N-type 2” Spool mount

    B+, B-, WL, S, ExC, AC

    17mm shaft

    No fan or pulley supplied

    CumminsHobartWhite110-4623604478, 39114623604478Rx, EE9028402505505, 402505506

    8HC2023KS 12V 51A INSULATED NO BI-DIR N-type 1” Spool mount

    B+, B-, AC

    5/8” shaft

    No pulley supplied

    Can use regulator +ve lead as sense lead

    Corrosion protected

    Caterpillar110-284712096, 0R3654, 6T13967T2096

    8HC2027PAS 12V 72A INSULATED NO BI-DIR N-type 2 Lug mount

    B+, B-, WL, ExC, AC

    5/8” shaft

    Double V,

    Can use regulator +ve lead as sense lead

    Various MarineVolvo110-5385034-110538LN110538

    8HC3022FS 24V 35A INSULATED NO BI-DIR N-type 1” Spool mount

    B+, B-, AC

    5/8” shaft

    No pulley supplied

    Can use regulator +ve lead as sense lead

    Corrosion protected

    API MarineCaterpillarMotorola110-28520150, 3T1395, 6P13956T1345, 6T1395, 7T2095OR3653

    8HC3026G 24V 42A INSULATED NO BI-DIR N-type 2” Spool mount

    B+, B-, S, ExC, AC

    5/8” shaft

    No pulley supplied

    Various Marine110-392100032214xx-L124714

  • MARINE PRODUCT GUIDE 2014ALTERNATORS

    Alte

    rnat

    orG

    uide

    www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113710 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No. OUTPUT POLARITYVOLT

    ADJUSTROTATION

    P / N TYPE FEATURES APPLICATION

    8LHA2070VF 12V 160A INSULATED NO CW N-type J-180 mount

    B+, B-, AC

    7/8” shaft

    No pulley supplied

    Can use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S(TSB-1112)

    Various MarineCumminsNapa MarineSabreVolvo3604670Rx, 3675200Rx3675158Rx, 3675218Rx3675236Rx407394, 34416 849747, 802010039

    8LHA2071VA 12V 160A INSULATED NO CW N-type J-180 mount

    B+, B-, WL, AC

    7/8” shaft

    No pulley supplied

    Can use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S(TSB-1112)

    Various Marine110-555IJHO10459040, 1045904810459111, 1901010419010120, 1901012419010125, 1901012919010145, 1901014719010178, 19010196

    8LHA3071P 24V 75A INSULATED YES CW N-type J-180 mount

    B+, B-, AC

    7/8” shaft

    No pulley supplied

    Can use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S(TSB-1112)

    CaterpillarCumminsPerkinsSabre MarineVolvoL2E31, 9011707079OD20382, 39206173920618, 39355313603848Rx, 3603853Rx3675201Rx, 3675212Rx

    8LHA3096U 24V 110A INSULATED YES CW N-type J-180 mount

    B+, B-, WL, AC

    7/8” shaft

    No pulley supplied

    Corrosion protectedCan use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S (TSB-1112)

    CumminsE.P. BarrusSabre marineVolvo3072483, 34006984078701, 3604685Rx3604687Rx, 3675103Rx3675104Rx27175, 9012724607

    8LHA3159R 24V 95A INSULATED NO CW N-type 3” Spool mount

    B+, B-, WL, AC

    7/8” shaft

    No puley supplied

    Can use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S(TSB-1112)

    Various MarineCummins3283806, 3975135,860323,DRA3795,CA4003

    8LHC2010Z 12V 160A INSULATED NO BI-DIR N-type J-180 mount

    B+, B-, AC

    7/8” shaft

    No pulley supplied

    Corrosion protected

    Volvo Penta110-2543969571, 802010048F2HS10346BA

  • www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137

    MARINE PRODUCT GUIDE 2014 ALTERNATORS

    11

    Alte

    rnat

    orG

    uide

    Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No. OUTPUT POLARITYVOLT

    ADJUSTROTATION

    P / N TYPE FEATURES APPLICATION

    8MH2003KS 12V 51A INSULATED NO BI-DIR N-type 1” Spool mount

    B+, B-, AC

    Unregulated

    5/8” shaft

    No pulley supplied

    Corrosion protected

    Caterpillar110-1332N7759, 2N77957418

    8MR2049KA 12V 51A INSULATED NO BI-DIR N-type 2” Spool mount

    B+, B-, WL, ExC, AC

    5/8” shaft

    No pulley supplied

    Can use regulator +ve lead as sense lead

    Corrosion protected

    Various Marine110-5177495, 2102508EM2007K8EM2007KA8MR2049K

    8MR2050FA 12V 37A INSULATED NO BI-DIR N-type 1” Spool mount

    B+, B-, WL, ExC, AC

    5/8” shaft

    No pulley supplied

    Can use regulator +ve lead as sense lead

    Corrosion protected

    CumminsMotorola110-5323675140Rx2103488EM2001FA8EM2001FAS8MR2050F

    8MR2058PA 12V 72A INSULATED NO BI-DIR N-type 2” Spool mount

    B+, B-, WL, ExC, AC

    Can use regulator +ve lead as sense lead

    Corrosion protected

    CumminsVolvo110-5211911600, LN11052174892102368MR2058P

    8MR2069TA 12V 90A INSULATED YES BI-DIR N-type 2” Spool mount

    B+, B-, ExC, AC

    17mm shaft

    No pulley supplied

    Can use regulator +ve lead as sense lead

    Corrosion protected

    Various Marine110-60230347321787691

    8MR2070TA 12V 90A INSULATED YES BI-DIR N-type 1” Spool mount

    B+, B-, AC

    5/8” shaft

    No pulley supplied

    Can use regulator +ve lead as sense lead

    Corrosion protected

    API MarineMercuryMotorola110-60379635182298220096

  • MARINE PRODUCT GUIDE 2014ALTERNATORS

    Alte

    rnat

    orG

    uide

    www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113712 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No. OUTPUT POLARITYVOLT

    ADJUSTROTATION

    P / N TYPE FEATURES APPLICATION

    8MR2091KSS 12V 51A INSULATED NO CW N-type 2” Spool mount

    B+, B-, WL, S, ExC, AC

    5/8” shaft

    Corrosion protected

    Various MarineMercuryVolvo17399, 78403, 78403A209854650, 3853853

    8MR2092L 12V 65A INSULATED NO CW N-type 2” Spool mount

    B+, B-, WL, S, ExC, AC

    5/8” shaft

    Single V, 66.5mm

    Corrosion protected

    Various Marine110-483824-0049

    8MR2093L 12V 65A INSULATED NO CW N-type 2” Spool mount

    B+, B-, WL, S, ExC, AC

    5/8” shaft

    Single V, 66.5mm

    Corrosion protected

    Various Marine110-484

    8MR2175F 12V 37A INSULATED NO CW N-type 1” Spool mount

    B+, B-, WL, S, ExC, AC

    5/8” shaft

    No pulley supplied

    Corrosion protected

    Various Marine110-6993675146Rx110399, 8EK2008F8EK2008FA, 8EK2008FB8EK2008FC, 8EK2008FD8EK2009FA, 8EK2009FB8EK2009FC

    8MR2185L 12V 65A INSULATED NO CW N-type 1” Spool mount

    B+, B-, S, ExC, AC

    5/8” shaft

    No pulley supplied

    Corrosion protected

    Misc Marine3675147Rx8EK2007N, 8EK2007NA8EK2007NB, 8EK2007NC8EK2007ND, 8EK2010NA8EK2010NB, 8EK2010NC8EK2010ND, 8EK2012NA8EK2012NB7480, 210407

    8MR2198L 12V 65A INSULATED NO BI-DIR N-type 1” Spool mount

    B+, B-, ExC, AC

    5/8” shaft

    No pulley supplied

    Can use regulator +ve lead as sense lead

    Corrosion protected

    CumminsMotorolaVolvoYamaha

    8EM2012N, 8EM2012NA8EM2012NAS

  • www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137

    MARINE PRODUCT GUIDE 2014 ALTERNATORS

    13

    Alte

    rnat

    orG

    uide

    Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No. OUTPUT POLARITYVOLT

    ADJUSTROTATION

    P / N TYPE FEATURES APPLICATION

    8MR2199KS 12V 51A INSULATED NO BI-DIR N-type 1” Spool mount

    B+, B-, WL, ExC, AC

    5/8” shaft

    No pulley supplied

    Can use regulator +ve lead as sense lead

    Corrosion protected

    Chris CraftMotorolaPleasure Craft110-6560665000337350, 7384, 7404, 7423RA0970048EM2005K, 8EM2005KA8MA2004K

    8MR2401UA 12V 105A INSULATED YES BI-DIR N-type 1” Spool mount

    B+, B-, AC

    5/8” shaft

    No pulley supplied

    Can use regulator +ve lead as sense lead

    Corrosion protected

    Various Marine110-567, 110-534

    8MR3188K 24V 55A INSULATED NO CW N-type 1” Spool mount

    B+, B-, AC

    17mm shaft

    No pulley supplied

    Can use regulator +ve lead as sense lead

    Corrosion protected

    Various MarineCaterpillar110-55711280321547993

    8MR3301G 24V 40A INSULATED NO BI-DIR N-type 2” Spool mount

    B+, B-, WL, S, ExC, AC

    17mm shaft

    No pulley supplied

    Corrosion protected

    Cummins39105758EK3006GA, 8EM3001GA

    8MR3404G 24V 40A INSULATED NO BI-DIR N-type 1” Spool mount

    B+, B-, ExC, AC

    5/8” shaft

    No pulley supplied

    Can use regulator +ve lead as sense lead

    Corrosion protected

    CumminsMotorolaWhiteYamaha110-684C0191157000MH24N901 MH24N901B8EM3003G, 8EM3003GA402500106

    8SC3133U 24V 100A INSULATED YES CW N-type J-180 mount

    B+, B-, WL, ExC, AC

    V adjust 26.8V - 29.5V

    7/8” shaft

    No pulley supplied

    CumminsE.P. BarrusSabreVolvo8SC3014U, 110-2982720871RDG20198933279220, 263102557832, 25578329LN110298

  • MARINE PRODUCT GUIDE 2014ALTERNATORS

    Alte

    rnat

    orG

    uide

    www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113714 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No. OUTPUT POLARITYVOLT

    ADJUSTROTATION

    P / N TYPE FEATURES APPLICATION

    8SC3157V 24V 175A INSULATED YES CW N-type J-180 mount

    B+, B-, WL, ExC, AC

    V adjust 26.8V - 29.5V

    7/8” shaft

    No pulley supplied

    API MarineCaterpillar, CumminsMTU, Sabre8SC3009ZA, 110-258200833001117, 30883203629351, 2687423520958

    8SC3160V 24V 150A INSULATED YES CW N-type J-180 mount

    B+, B-, WL, ExC, AC

    V adjust 26.8V - 29.5V

    7/8” shaft

    No pulley supplied

    CaterpillarCummins8SC3068V, 110-4311501935, 3640732

    8SC3169U 24V 100A INSULATED YES CW N-type J-180 mount

    B+, B-, WL, ExC, AC

    V adjust 26.8V - 29.5V

    7/8” shaft

    No pulley supplied

    Various MarinePerkinsVolvo8SC3015U, 110-302OE52360562612

    A0012303JB 24V 45A INSULATED NO BI-DIR N-type J-180 mount

    B+, B-, AC

    7/8” shaft

    No pulley supplied

    Corrosion protected

    Volvo PentaCaterpillarCummins2303JB0R2698, 0R5217, 3N27023N2706, 3T6352, 3Y66915N5692, 6N5217, 6N92949G8255111640, 3015516, 3604676Rx3675126Rx

    A0014727JB 24V 140A INSULATED YES CW N-type J-180 mount

    B+, B-, ExC, AC

    V adjust 26.0V - 32.0V

    7/8” shaft

    No pulley supplied

    Various MarineVolvo4727JBLN4727JB

    A0014740JB 24V 200A GROUNDED NO CW N-type J-180 mount

    B+, B-, AC

    7/8” shaft

    No pulley supplied

    Various Marine4740JB

  • www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137

    MARINE PRODUCT GUIDE 2014 ALTERNATORS

    15

    Alte

    rnat

    orG

    uide

    Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No. OUTPUT POLARITYVOLT

    ADJUSTROTATION

    P / N TYPE FEATURES APPLICATION

    A0014742JB 24V 200A GROUNDED NO CW N-type J-180 mount

    B+, B-, ExC, AC, Rx

    Multipower unit

    7/8” shaft

    No pulley supplied

    Various Marine4742JB

    A0014980PGH 24V 200A INSULATED NO CW N-type Pad mount

    B+, B-, AC

    7/8” shaft

    No pulley supplied

    MTUx51621300001x57521300020A0014980PAHA0014980PAH-P

    A0014989PGH 24V 190A INSULATED NO BI-DIR N-type Pad mount

    B+, B-, D+, AC

    7/8” shaft

    No pulley supplied

    MTU, MANx57521300025x5162130003451261017312A0014989PAHA0014989PAH-1A0014989PAH-2

    AVi136A2004 12V 125A GROUNDED NO CW Swung mount

    B+, B-, WL, AC

    20mm shaft

    6pk, 56mm pulley

    Various Marine

    AVi136A3002 24V 75A GROUNDED NO CW Swung mount

    B+, B-, WL, AC

    20mm shaft

    8pk, 50mm pulley

    Various Marine

    AVi1441F11 12V 150A GROUNDED NO CW Swung mount

    B+, B-, WL, AC

    20mm shaft

    4pk, 60mm pulley

    Various Marine

  • MARINE PRODUCT GUIDE 2014ALTERNATORS

    Alte

    rnat

    orG

    uide

    www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113716 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No. OUTPUT POLARITYVOLT

    ADJUSTROTATION

    P / N TYPE FEATURES APPLICATION

    AVi1442A21 24V 105A GROUNDED NO CW Swung mount

    B+, B-, WL, AC

    20mm shaft

    8pk, 50mm pulley

    Various Marine

    AVi144B2008 12V 150A GROUNDED NO CW Swung mount

    B+, B-, WL, AC

    20mm shaft

    Double V, 75mm pulley

    Various Marine

    AVi144B2018 12V 150A GROUNDED NO CW Swung mount

    B+, B-, WL, AC

    20mm shaft

    6pk, 50mm pulley

    Various MarineE.P. BarrusRDG20110201

    AVi144C2006 12V 150A GROUNDED NO CW Swung mount

    B+, B-, WL, AC

    20mm shaft

    8pk, 55mm pulley

    Various Marine

    AVi144C3002 24V 105A GROUNDED NO CW Swung mount

    B+, B-, WL, AC

    20mm shaft

    8pk, 55mm pulley

    Various Marine

    AVi144N1C 24V 105A GROUNDED NO CW Swung mount

    B+, B-, WL, AC

    20mm shaft

    No pulley supplied

    Various Marine

    B +

    W

    D+

    D+ E

    B +

    E

    B +

    W

    D+

    D+ E

    B +

    E

  • www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137

    MARINE PRODUCT GUIDE 2014 ALTERNATORS

    17

    Alte

    rnat

    orG

    uide

    Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No. OUTPUT POLARITYVOLT

    ADJUSTROTATION

    P / N TYPE FEATURES APPLICATION

    AVi147J3110HD 24V 120A GROUNDED NO BI-DIR J-180 mount

    B+, B-, WL, ExC, AC

    17mm shaft

    No pulley supplied

    Corrosion protected

    Volvo207416862077001621429791

    AVi147S3108HD 24V 120A GROUNDED NO BI-DIR Swung mount

    B+, B-, WL, ExC, AC

    17mm shaft

    8pk, 55mm pulley

    Corrosion protected

    Cummins5284097

    AVi160J2004 12V 240A INSULATED NO BI-DIR P-type J-180 mount

    B+, B-, WL, S, AC

    7/8” shaft

    No pulley supplied

    Corrosion protected

    Various MarineCumminsE.P. BarrusA160204RDG20196820124525085, 0124625044AL9960LH, AL9963SB3972732

    AVi160J2008 12V 210A INSULATED NO BI-DIR P-type J-180 mount

    B+, B-, WL, S, AC

    7/8” shaft

    No pulley supplied

    Corrosion protected

    Various MarineCumminsA1602080124525085, 0124625044AL9960LH, AL9963SB3972732

    AVi160P2003 12V 240A INSULATED NO BI-DIR P-type Pad mount

    B+, B-, WL, S, AC

    7/8” shaft

    No pulley supplied

    Corrosion protected

    Various MarineE.P. BarrusA1602030124625043, 01246250460124625048, 0124625051AL9961LH, AL9962SB

    BLD2308GH 12V 160A INSULATED NO CW N-type J-180 mount

    B+, B-, WL, AC

    7/8” shaft

    No pulley supplied

    Can use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S(TSB-1112)

    Various MarineE.P. BarrusRDG2017370

  • MARINE PRODUCT GUIDE 2014ALTERNATORS

    Alte

    rnat

    orG

    uide

    www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113718 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No. OUTPUT POLARITYVOLT

    ADJUSTROTATION

    P / N TYPE FEATURES APPLICATION

    BLD2333GH 12V 185A INSULATED NO CW N-type J-180 mount

    B+, B-, WL, S, AC

    7/8” shaft

    No pulley suppliedConvert to ext reg with cover A038102788S(TSB-1112)

    Various MarineVolvoLNBLD2333GH

    BLD3314GH 24V 140A INSULATED YES CW N-type J-180 mount

    B+, B-, WL, AC

    7/8” shaft

    No pulley supplied

    Can use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S(TSB-1112)

    Various MarineCumminsMTU3975140, 52932135241500150x5271300005

    BLD3338GH 24V 140A INSULATED YES CW N-type J-180 mount

    B+, B-, WL, AC, Rx

    Multipower unit

    7/8” shaft, No pulley supplied

    Corrosion protectedCan use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S (TSB-1112)

    Various MarineMTUx52721300001x52721300005

    BLD3365GH 24V 140A INSULATED YES CW N-type J-180 mount

    B+, B-, WL, AC

    7/8” shaft

    No pulley supplied

    Corrosion protectedCan use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S (TSB-1112)

    Various MarineCumminsBLD3315GH3975140

    BLP2310GH 12V 160A INSULATED NO CW N-type Pad mount

    B+, B-, WL, AC

    7/8” shaft

    No pulley supplied

    Can use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S(TSB-1112)

    Various MarineVolvo8600066, 87000018700002, 87000048700007, 87000188700030

    BLP2362GH 12V 200A INSULATED NO CW N-type Pad mount

    B+, B-, WL, S, AC

    7/8” shaft

    No pulley suppliedConvert to ext reg with cover A038102788S(TSB-1112)

    Various Marine8600066, 86001278700001, 87000028700004, 87000078700018, 87000308700047

  • www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137

    MARINE PRODUCT GUIDE 2014 ALTERNATORS

    19

    Alte

    rnat

    orG

    uide

    Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No. OUTPUT POLARITYVOLT

    ADJUSTROTATION

    P / N TYPE FEATURES APPLICATION

    BLP3312 24V 140A INSULATED YES CW N-type Pad mount

    B+, B-, WL, AC

    7/8” shaft

    No pulley supplied

    Can use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S(TSB-1112)

    CaterpillarMTUVolvo110-816200619x57521300012BLP3337H-P

    BLP3317A 24V 140A INSULATED YES CW N-type Pad mount

    B+, B-, WL, AC

    7/8” shaft

    No pulley supplied

    Corrosion protectedCan use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S (TSB-1112)

    Various Marine

    BLP3300GH 24V 140A INSULATED NO CW N-type Pad mount

    B+, B-, D+, AC

    7/8” shaft

    No pulley supplied

    Can use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S(TSB-1112)

    MTUx51621300033x5752130002451261017307BLP3300HBLP3300H-1BLP3300H-2

    MDA2919 12V 150A INSULATED NO CW N-type J-180 mount

    B+, B-, WL, AC

    7/8” shaft

    No pulley suppliedConvert to ext reg with cover K185103982S(TSB-1116)

    Various Marine

    MDA2932 12V 150A INSULATED NO CW N-type J-180 mount

    B+, B-, WL, AC

    7/8” shaft

    No pulley suppliedConvert to ext reg with cover K185103982S(TSB-1116)

    Various MarineCaterpillarCummins110-4441214134, 0R3527, 39355273935528,39355293604668Rx, 3675222Rx

    MDA3929 24V 80A INSULATED NO CW N-type J-180 mount

    B+, B-, WL, S, AC

    7/8” shaft

    No pulley suppliedConvert to ext reg with cover K185103982S(TSB-1116)

    CumminsMDA39273967726

  • MARINE PRODUCT GUIDE 2014ALTERNATORS

    Alte

    rnat

    orG

    uide

    www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113720

    PART No. OUTPUT POLARITYVOLT

    ADJUSTROTATION

    P / N TYPE FEATURES APPLICATION

    MDA3946 24V 80A INSULATED NO CW N-type J-180 mount

    B+, B-, WL, AC

    7/8” shaft

    No pulley suppliedConvert to ext reg with cover K185103982S(TSB-1116)

    Various MarineCaterpillarCummins1077977, 13221563056492, 3251135, 36751743675201, 3920617, 39206183935530, 4000590, 40034464936879, 6375174 3675174Rx, 3675226Rx3675242Rx, 11039152

    MDP2934 12V 150A INSULATED NO CW N-type Pad mount

    B+, B-, WL, AC

    Can use regulator +ve lead as sense lead

    7/8” shaft

    No pulley suppliedConvert to ext reg with cover K185103982S(TSB-1116)

    Various Marine110-444P10459320, 1045932110459340, 1045934119020387, 1902038819020888, 1902088919020900, 8700008

    MDP3939H 24V 55A INSULATED NO CW N-type Pad mount

    B+, B-, WL, AC

    Can use regulator +ve lead as sense lead

    7/8” shaft

    No pulley suppliedConvert to ext reg with cover K185103982S(TSB-1116)

    MTUx57517200011x57521300010

    MDP3941 24V 80A INSULATED NO CW N-type Pad mount

    B+, B-, WL, AC

    Can use regulator +ve lead as sense lead

    7/8” shaft

    No pulley suppliedConvert to ext reg with cover K185103982S(TSB-1116)

    MTUMANx51621300032x5752130002351261017308

  • Sta

    rte

    r m

    oto

    rS

    Sta

    rte

    rS

    Dém

    ar

    reu

    rS

    mo

    tor

    eS D

    e a

    rr

    an

    qu

    em

    oto

    rin

    i D’a

    vvia

    men

    to

    mo

    tor

    eS D

    e pa

    rti

    Da

    ro

    zru

    Szn

    iki

    elec

    tro

    mo

    toa

    re

    ElEk

    tropo

    krEt

    ači

    Ста

    ртер

    ы

  • MARINE PRODUCT GUIDE 2014STARTER MOTORS

    www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113722

    Sta

    rter

    Mot

    orG

    uide

    Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)

    PAR(ENG) FEATURES APPLICATION

    860516GB 24V 5.4kW CW GROUNDED 11t 40.8(M3)48

    (69)SAE3 mounting

    B+, B-, IGN

    Corrosion protected

    AIFOIveco0001410106, 00014150170001416011, 000141601209860134204784745, 478474761583669

    860518GB 24V 5.4kW CW INSULATED 11t 40.8(M3)48

    (69)SAE1 mounting

    B+, B-, IGN

    Corrosion protected

    Volvo Penta, KHD0001410050, 00014106020001415021, 00014160531164269240347, 847330, 8708704776105, 110311263

    860541GB 24V 6.6kW CW INSULATED 11t 40.8(M3)48

    (69)SAE1 mounting

    B+, B-, IGN

    Corrosion protected

    Volvo Penta0001411010, 000141702300014170355010217950847308, 870998, 8816823803080, 38035984777147, 8473084

    860543GB 24V 5.4kW CW INSULATED 9t 34.8(M3)48

    (69)SAE1 mounting

    B+, B-, IGN

    Corrosion protected

    Volvo Penta0001402072, 00014020790001414011, 0001416028240503, 241011, 842774843510, 847307, 8707298473076

    860545GB 24V 5.4kW CW GROUNDED 11t 40(M3)21

    (42.7)SAE3 mounting

    B+, B-, IGN

    Corrosion protected

    AIFO, DeutzIveco0001417005, 00014170060001417059, 00014170730001417074, 09860134300986013440, 09860188104684280, 47322414179626, 4732242, 47828024782803, 500325102500325103

    1391010A 24V 15kW CW INSULATED 11t 56.6(6/8 DP)47.6

    (71.6)SAE3 mounting

    B+, B-, IGN, R, A

    Corrosion protected

    MTUx524172000071391002, 13910061391008, 1391009S152-24-2, S152-25-6S152-24-7, 152-24-8S152-24-9A, S152-24-10

  • www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137

    MARINE PRODUCT GUIDE 2014 STARTER MOTORS

    23 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    Sta

    rter

    Mot

    orG

    uide

    PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)

    PAR(ENG) FEATURES APPLICATION

    1327A021 12V 3.6kW CW INSULATED 10t 39.5(8/10 DP)47.6 (67)

    SAE1 mounting

    B+, B-, IGN

    CAVPerkinsSabre47920090LRT00618, LRT00641LRS019772873155(R), 2873A0272873155CA45D/F/G/H12-3MS115A12-3M

    1327A031 12V 3.6kW CW INSULATED 10t 39.5(8/10 DP)20.6 (40)

    Special mounting

    B+, B-, IGN

    Corrosion protected

    CAVSabre26302, 40021LRT606, LRT645CA45D/F/G12-55MS115A12-4M

    1327A081 12V 3.6kW CW INSULATED 11t 34.7(10/12 DP)47.6 (67)

    SAE1 (offset) mounting

    B+, B-, IGN

    Corrosion protected

    CAVCummins3910563LRS01536CA45G/H12-125MS115A12-11M1320G934, 1320H934

    1327A121 12V 3.6kW CW INSULATED 13t 45.8(8/10 DP)47.6 (67)

    SAE1 mounting

    B+, B-, IGN

    Corrosion protected

    CAVLister PetterPerkins35136920LRT619, LRT6562873160CA45F/G/H12-11MCA45F/G12-95MS115A12-15M

    1327A141 12V 3.6kW CW INSULATED 9t 35.7(M3)26.5 (26)

    Special mounting

    B+, B-, IGN

    Corrosion protected

    CAVIveco802208CA45G12-121MS115A12-30M1321G938

    1327A431 24V 7.8kW CW INSULATED 10t 39.5(8/10 DP)47.6 (67)

    SAE1 mounting

    B+, B-, IGN

    Corrosion protected

    CAV, Lister PetterPerkins, Sabre366044872873303, 28733262873335, 2873303R2873K062CA45D/F/G/H24-3MS115A24-3M1321F/G0321321F/G/H033

  • MARINE PRODUCT GUIDE 2014STARTER MOTORS

    www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113724

    Sta

    rter

    Mot

    orG

    uide

    Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)

    PAR(ENG) FEATURES APPLICATION

    1327A441 24V 7.8kW CW INSULATED 10t 39.5(8/10 DP)20.6 (40)

    Special mounting

    B+, B-, IGN

    Corrosion protected

    CAVSabre19820, 40020LRT615, LRT653CA45D/F/G24-55MCA45G24-124MS115A24-4M1321F/G5511321G934

    1327A501 24V 7.8kW CW INSULATED 11t 34.7(10/12 DP)47.6 (67)

    SAE1 (offset) mounting

    B+, B-, IGN

    Corrosion protected

    CAVCummins3910564CA45F/G/H24-125MS115A24-11M1321F/G/H936

    1327A541 24V 7.8kW CW INSULATED 13t 45.8(8/10 DP)47.6 (67)

    SAE1 mounting

    B+, B-, IGN

    Corrosion protected

    CAVLister PetterPerkins35136940, 3513696035136970, 28733322873336CA45D/F/G/H24-11MCA45G24-95MS115A24-15M1321F/G/H112

    1327A551 24V 7.8kW CW INSULATED 10t 39.5(8/10 DP)20.6 (40)

    SAE1 mounting

    B+, B-, IGN

    Corrosion protected

    CAVDorman DieselLister Petter701120, 29745736607703CA45GH24-104MS115A24-16M1321G/H906

    1327A691 24V 7.8kW CW INSULATED 9t 35.7(M3)26.5 (26)

    Special mounting

    B+, B-, IGN

    Corrosion protected

    CAVAIFOLRT631, LRT640CA45F/G24-121MS115A24-30M1321F/G9291321G938

    20500120 12V 2.1kW CW GROUNDED 10t 40(8/10 DP)25.7

    (14.4)SAE1 mounting

    B+, B-, IGN

    DAF26310, 2742447920122LRS120

  • www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137

    MARINE PRODUCT GUIDE 2014 STARTER MOTORS

    25 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    Sta

    rter

    Mot

    orG

    uide

    PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)

    PAR(ENG) FEATURES APPLICATION

    20500124 12V 2.1kW CW GROUNDED 10t 40(8/10 DP)29

    (45)SAE1 mounting

    B+, B-, IGN

    API MarinePerkins2873121, 2873141 2873121T, 2873A0102873A010R, 2873A1022873D00327417, 27435, 27486NSB503, LRS124, LRS153LUC101

    20500157 12V 2.1kW CW GROUNDED 11t 39.5(M3)23

    (41)SAE1 modified mountingB+, B-, IGN

    Perkins0001362060, 9004475303NSB415, NSB507NSB513LRS00131, LRS001572873168

    20500190 12V 2.1kW CW GROUNDED 10t 39.5(8/10 DP)25

    (43)SAE1 modified mountingB+, B-, IGN

    Perkins0001362008, 00013620490986050570NSB509, LRS001902873143, 2873A012(T)2873A017(R), 2873A1042873D005, 2873D007

    20500555 12V 2.1kW CCW GROUNDED 11t 39.5(M3)23

    (41)SAE1 modified mountingB+, B-, IGN

    Lister Petter2041327326270, 27410LRS00555

    20500839 24V 3.0kW CW GROUNDED 9t 34.8(M3)27.5

    (40.5)SAE1 modified mountingB+, IGN

    Iveco0986011160, 09860111614744811, 474484192900352, 92900518504038038, 504072485

    20500850 12V 2.4kW CW GROUNDED 9t 34.8(M3)27.5

    (40.5)SAE1 modified mountingB+, IGN

    FiatIveco0001359091, 00013620320001362039, 000136210509860126704728682, 4807373500333269LRS00850

  • MARINE PRODUCT GUIDE 2014STARTER MOTORS

    www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113726

    Sta

    rter

    Mot

    orG

    uide

    Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)

    PAR(ENG) FEATURES APPLICATION

    20500923GB 24V 2.9kW CW GROUNDED 9t 34.8(M3)28

    (46)SAE1 mounting

    B+, IGN

    Deutz, IvecoKHD, Volvo0001360012, 00013600140001360030, 00013600350001368001, 000136800709860112701161422, 1164995, 11720991173241, 1173820, 130202342488477, 425226536209190

    20500968 12V 2.8kW CW GROUNDED 10t 40(8/10 DP)29

    (46)SAE1 mounting

    B+, B-, IGN

    Perkins 0001367069, 098601815109860503512873001(R), 2873A0012873A030, 2873B056(R)2873B071NSB522, NSB524, NSB526LRS00161, LRS00195LRS00691, LRS00968

    20500969 12V 2.8kW CW GROUNDED 10t 40(8/10 DP)29

    (46)SAE1 mounting

    B+, B-, IGN

    Perkins2873006R/T, 2873A0142873A029, 2873A0312873B053, 2873B0552873B057(R), 2873B0612873B072, 2873B0732873D002,NSB529, NSB531NSB540, LRS00232LRS00300, LRS02048

    20513033 12V 2.0kW CW GROUNDED 9t 34(M3)26

    (39)Special mounting

    B+, IGN

    Mercruiser1946063011, 19460630121946063013, 22800006912280004570, 22800045712280004572, 22800047502280004752

    20513040 12V 1.4kW CW GROUNDED 9t 34(M3)26

    (39)Special mounting

    B+, IGN

    API Marine0986024270LRS0112917050

    20513065 12V 2.0kW CW GROUNDED 15t 44 21(36) Special mountingB+, IGN

    Yanmar12125477010, 1212547701112125477012, 1212567701012497677010, 1249767701112913077010, 1294007701012940077011, 1294007701217100877010, S114257S114349/A, S114483, S13124, S13294S1341/A/B/C/D, S1394

  • www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137

    MARINE PRODUCT GUIDE 2014 STARTER MOTORS

    27 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    Sta

    rter

    Mot

    orG

    uide

    PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)

    PAR(ENG) FEATURES APPLICATION

    20550101 12V 2.2kW CW INSULATED 10t 39.3(8/10 DP)29

    (41)SAE1 mounting

    B+, B-, IGN

    Corrosion protected

    API MarineLucas MarinePerkins, Volvo47200628, 4792003447920141, NSB418LRS01339, LRS015032873B058, 2873B059859722LUC102, LUC103

    20550103 24V 4.0kW CW INSULATED 10t 32(10/12 DP)47

    (69)SAE1 (offset) mounting

    B+, B-, IGN

    CumminsDAF00013680673283721AELD190(R)

    M93R3004SE 24V 5.5kW CW INSULATED 10t* 38.1(M3) 28 (44)SAE1 (offset) mounting

    B+, IGN

    *Replacing Bosch 9t starter

    Deutz, KHDIveco, MANMercedes-Benz0001231028, 00013641000001364301, 00013680010986012700, 09860210001163626, 117958601180999, 0118223542522942

    M97R3014SE 24V 5.5kW CW INSULATED 10t 39.6(8/10 DP)47.5 (64)

    SAE1 mounting

    B+, B-, IGN

    CumminsC4934622

    M100R2014SE 12V 4.0kW CW GROUNDED 10t* 38.1(M3)28

    (44)SAE1 (offset) mounting

    B+, IGN

    *Replaces Bosch 9t starter

    Cummins, Deutz,KHD, Volvo 5263797, 8500044101182233, 0118292501183120, 0118323501183677, 011837121163669, 11646681164994, 11732401174166, 1178026

    M100R2015SE 12V 4.0kW CW GROUNDED 10t 39.7(8/10 DP)29

    (45)SAE1 mounting

    B+, B- (earthed), IGN

    Perkins2873K604, 2873K60500013670406005003154, 60050212726005700081, 77000118507701031686

  • MARINE PRODUCT GUIDE 2014STARTER MOTORS

    www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113728

    Sta

    rter

    Mot

    orG

    uide

    Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)

    PAR(ENG) FEATURES APPLICATION

    M100R2016SE 12V 4.0kW CW GROUNDED 10t 39.7(8/10 DP)29

    (45)SAE1 mounting

    B+, B- (earthed), IGN

    Perkins2873K6012873K6070001367069, 09860181510986050351

    M105R2511SE 12V 5.0kW CW INSULATED 10t 39.9(8/10 DP)47.5

    (66.5)SAE1 mounting

    B+, B-, IGN

    Rotatable mounting & relay

    Caterpillar7N09231993754, 1993762, 19937691993799, 1993881, 19938861993947, 1993963, 82000768300021, 1046100310461081, 1046122510461282, 1046176810478953, 1047895710479036, 10479226

    M105R2512SE 12V 5.0kW CW INSULATED 12t 46.6(8/10 DP)47.5

    (66.5)SAE1 mounting

    B+, B-, IGN

    Rotatable mounting & relay

    Caterpillar1993885, 1046143110461434, 1046145610461496, 1047901410479071, 1047909810479206, 1047920710479215, 10479242

    M105R3037SE 24V 7.5kW CW INSULATED 14t 50.0(M3)48.5

    (67.5)Special mounting

    B+, B-, IGN

    MTU

    M105R3050SE 24V 7.5kW CW INSULATED 12t 44.1(M3)48.5

    (67.5)Special mounting

    B+, B-, IGN

    MTUx51117200001M105R3013SE

    M105R3086SE 24V 7.5kW CW INSULATED 12t 46.6(8/10 DP)47.5

    (66.5)SAE3 mounting

    B+, B-, IGN

    MTUx57517200010M105R3065SE

  • www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137

    MARINE PRODUCT GUIDE 2014 STARTER MOTORS

    29 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    Sta

    rter

    Mot

    orG

    uide

    PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)

    PAR(ENG) FEATURES APPLICATION

    M105R3087SE 24V 7.5kW CW INSULATED 12t 46.6(8/10 DP)47.5

    (66.5)SAE1 mounting

    B+, B-, IGN

    MTUx57517200011M105R3066SE

    M105R3095SE 24V 7.5kW CW INSULATED 12t 46.6(8/10 DP)47.5

    (66.5)SAE1 mounting

    B+, B-, IGN

    MTUx54417200004M105R3051SE

    M105R3502SE 24V 7.5kW CW INSULATED 11t 57.6(6/8 DP)47.5

    (66.5)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting & relay

    Cummins, Caterpillar10R0400, 4N1062, 6V55397T0794, 7T0800, 7T08017T08061443674, 30210363103305, 31039163103952, 52840851443674R, 3021036Rx3603862RxCH12405

    M105R3504SE 24V 7.5kW CW GROUNDED 12t 46.7(8/10 DP)47.5

    (66.5)SAE1 mounting

    B+, B- (earthed), IGN

    Rotatable mounting & relay

    Caterpillar, Perkins2873K116, 10470401068557,10685582071511, 20715162071517, 20715190R4263, 10R03956V5720, OR4263

    M105R3505SE 24V 7.5kW CW INSULATED 12t 46.7(8/10 DP)47.5

    (66.5)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting & relay

    Caterpillar, Cummins, Perkins1068552, 20715522071553, 207156010R0399, 3P00075A6494, 3011895, 31027633281634, 3675297, 3902661 3907821, 3910646, 39308453938499, 3938503, 39774264891301, 3604233Rx3604484Rx, 3675120Rx

    M105R3508SE 24V 7.5kW CW INSULATED 11t 57.6(6/8 DP)47.5

    (66.5)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting & relay

    Caterpillar, Cummins, FiatIveco, Renault3T2646, 3T2650, 6N18862T0797310391447809745000811448

  • MARINE PRODUCT GUIDE 2014STARTER MOTORS

    www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113730

    Sta

    rter

    Mot

    orG

    uide

    Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)

    PAR(ENG) FEATURES APPLICATION

    M105R3509SE 24V 7.5kW CW INSULATED 12t 46.7(8/10 DP)47.5

    (66.5)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting & relay

    Cummins3102767, 39774285254108, 52564155284108M009T82671M009T82672

    M105R3510SE 24V 7.5kW CW GROUNDED 10t 40(8/10 DP)47.5

    (66.5)SAE1 (offset) mounting

    B+, B- (Earthed), IGN

    Rotatable mounting & relay

    Cummins3675116, 3965282384011001503675116Rx

    M105R3513SE 24V 7.5kW CW INSULATED 12t 46.7(8/10 DP)47.5

    (66.5)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting & relay

    Volvo Penta3801289, 38038383586798M009T82179M009T84079

    M105R3514SE 24V 7.5kW CW INSULATED 12t 44.1(M3)47.5

    (66.5)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting & relay

    Mercedes-BenzInsulated version of 0001330011, 00013300200001372005, 00013720060986018370, 09860208800986022980M009T80471, M009T80472M009T80473, M009T83671M009T84771

    M110R2601SE 12V 7.0kW CW INSULATED 12t 44.1(M3)47.5

    (66.5)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting & relay

    Corrosion protected

    Mercedes-BenzM009T70379M009T7117919011505, 190115148200084, 82004348300013

    M110R2602SE 12V 7.0kW CW INSULATED 12t 46.7(8/10 DP)47.5

    (66.5)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting & relay

    Corrosion protected

    Volvo21019456, 21019460M9T71179MK2078MK2079VV2079

  • www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137

    MARINE PRODUCT GUIDE 2014 STARTER MOTORS

    31 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    Sta

    rter

    Mot

    orG

    uide

    PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)

    PAR(ENG) FEATURES APPLICATION

    M110R2603SE 12V 7.0kW CW INSULATED 11t 57.6(6/8 DP)47.5

    (66.5)SAE3 mounting

    B+, B-, IGN

    Overcrank protection

    Rotatable mounting & relay

    Corrosion protected

    Caterpillar, Cummins3604665(Rx)10461028, 1046105510461062, 1046107510461096, 1046116510461183, 1046118510461232, 1047903010479038, 1047906210479082

    M110R2615SE 12V 7.0kW CW INSULATED 11t 57.6(6/8 DP)47.5

    (66.5)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting & relay

    Corrosion protected

    Caterpillar, Cummins3815734C91M983579, MIB970777(FL)MIB970975(FL)8200050, 8200090, 82000918200104, 8200289, 82002908200308, 8300009, 830001919011518, 1901152119011529, 19011530

    M125R2001SEP 12V 8.0kW CW INSULATED 11t 57.6(6/8 DP)47.5

    (66.5)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting

    Corrosion protected

    Caterpillar, Cummins3021034, 30210353610942, 3603863Rx3604322Rx3T3154, 4L9547, 4N09564N1064, 4N956, 5L41605L4168, 5L4169, 5L56675L5867, 8C3592, 8C35938C3652, 8L8206, 9L62009N0716, 9N0721

    M125R2600SE 12V 8.0kW CW INSULATED 14t 50.5(M3)48.5

    (69.5)SAE3 (offset) mounting

    B+, B-, IGN

    Rotatable mounting & relay

    Corrosion protected

    Detriot DieselMIB970379, MIB9711798200082, 82000848200287, 82002988200329, 83000088300013, 830005819011514, 19011525

    M125R2632SE 12V 8.0kW CW INSULATED 11t 57.6(6/8 DP)48.5

    (69.5)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting & relay

    Corrosion protected

    CumminsMIB70579(FL)MIB970777(FL)MIB970975(FL)8200050, 82000908200091, 82001048200289, 82002908200308, 830001919011518, 1901152119011529, 19011530

    M125R2634SE 12V 8.0kW CW INSULATED 12t 46.3(8/10 DP)48.5

    (69.5)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting & relay

    Corrosion protected

    Volvo8200182, 82002148200417, 8200572830006021019456, 21019460MK2078, MK2079VV2079, VV2080

  • MARINE PRODUCT GUIDE 2014STARTER MOTORS

    www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113732

    Sta

    rter

    Mot

    orG

    uide

    Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)

    PAR(ENG) FEATURES APPLICATION

    M125R3001SE 24V 9.0kW CW INSULATED 11t 57.6(6/8 DP)48.5

    (69.5)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting & relay

    Corrosion protected

    Caterpillar, Cummins4M5615, 4N0959, 4N33434N3349, 5L3648, 5L44055L5353, 5L648, 5L82055LG48, 5N2685, 6N96676N9677, 6T0647, 6V05116V0590, 8L8205, 9L64649L6474, 9L64843603868Rx, 3603888Rx3632273Rx, 3632274Rx

    MS1-401A 24V 8.3kW CW INSULATED 11t 57.1(6/8 DP)47.8(69)

    SAE3 mounting

    B+, B-, IGN

    Rotatable mounting

    Corrosion protected

    GR version M105R3502SE

    ButecCaterpillarCummins10R0400, 4N10626V5539, 7T0794, 7T08007T0801, 7T0806135160, 135161, 135162135163, 173006, 173007555241, 706620, 3021036

    MS1-410A 24V 8.3kW CW INSULATED 12t 46.3(8/10 DP)47.8(69)

    SAE3 mounting

    B+, B-, IGN

    Rotatable mounting

    Corrosion protected

    ButecCaterpillarCummins1068552, 10R03993P0007, 5A6494, 1971273011895, 32816343902661, 39078213910646, 39384993938502, 3604233Rx3604484Rx, 3675120Rx

    MS1-419A 24V 8.3kW CW INSULATED 12t 46.3(8/10 DP)47.8(69)

    SAE3 mounting

    B+, B-, IGN

    Rotatable mounting

    Corrosion protected

    Butec, CaterpillarCummins, Fiat, Iveco6V5207, 6V5226, 6V52276V5537, 7S3622, 7T07987T0799, 7T1082, 7T17998C3597, 8C3647, 8C36508C3651, 8N2145, 9G43389G4339, 9M1662, 9x44543604784Rx, 731301924816170

    MS1-464 24V 8.3kW CW INSULATED 12t 46.3(8/10 DP)47.8(69)

    SAE3 mounting

    B+, B-, IGN

    Rotatable mounting

    Corrosion protected

    ButecCumminsPerkinsMS6-301A5257544CV5296, CV65430 OD20399854006(Z)

    MS1-500 24V 8.3kW CW INSULATED 12t 46.3(8/10 DP)47.8(69)

    SAE1 mounting

    B+, B-, IGN

    Rotatable mounting

    Corrosion protected

    GR version M105R3504SE

    CaterpillarVolvo20715518723649000872364

  • www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137

    MARINE PRODUCT GUIDE 2014 STARTER MOTORS

    33 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    Sta

    rter

    Mot

    orG

    uide

    PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)

    PAR(ENG) FEATURES APPLICATION

    MS3-502 24V 7.5kW CW INSULATED 12t 46.3(8/10 DP)48.5(66)

    SAE3 mounting

    B+, B-, IGN

    Rotatable mounting

    Corrosion protected

    ButecCumminsPerkins3975134OD166001MS3-41850461, 854082, 850615(Z)855783(Z)ZMS3-502

    MS4-400 24V 5.5kW CW INSULATED 12t* 37.3(10/12 DP)48.5

    (64.7)SAE1 (offset) mounting

    B+, B-, IGN

    Rotatable mounting

    Corrosion protected

    *Replacing 10t LNS starter

    Cummins3399104859532, 860606LNS452411

    MS4-401 24V 5.5kW CW INSULATED 12t* 37.3(10/12 DP)48.5

    (64.7)SAE1 (offset) mounting

    B+, B-, IGN

    Rotatable mounting

    Corrosion protected

    *Replacing 10t LNS starter

    CumminsIveco3283586, 49306063281354Rx, 859500PB92901937, 929019443352622R91856766, 859411, 859422, 859500, 859970LNS452421, LNS452424LNS452426

    MS4-405 24V 5.5kW CW INSULATED 10t 39.7(8/10 DP)48.5

    (64.7)SAE1 mounting

    B+, B-, IGN

    Rotatable mounting

    Corrosion protected

    Cummins860362LNS4524

    MS4-406 24V 5.5kW CW INSULATED 10t 39.7(8/10 DP)29.6

    (45.8)SAE1 mounting

    B+, B-, IGN

    Rotatable mounting

    Corrosion protected

    Butec859024, 859432LNS45244, LNS45247

    MS4-407 24V 5.5kW CW INSULATED 10t 39.7(8/10 DP)48.5

    (64.7)SAE1 mounting

    B+, B-, IGN

    Rotatable mounting

    Corrosion protected

    ButecCummins860360(Z)LNS452431

  • MARINE PRODUCT GUIDE 2014STARTER MOTORS

    www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113734

    Sta

    rter

    Mot

    orG

    uide

    Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)

    PAR(ENG) FEATURES APPLICATION

    MS4-500A 24V 5.5kW CW INSULATED 12t* 37.3(10/12 DP)48.5

    (64.7)SAE1 (offset) mounting

    B+, B-, IGN

    Rotatable mounting

    Corrosion protected

    *Replacing 10t LNS starter

    Cummins3975153, 40788004930606MZH9195MS4-403859920, 857673ZLNS452425

    MS7-501A 24V 9.0kW CW INSULATED 11t 57.1(6/8 DP)45.8

    (69.7)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting

    Corrosion protected

    CumminsMTUMercedes-Benz4308730A0041519901A0051511001x00001906

    MS7-502A 24V 9.0kW CW INSULATED 11t 57.1(6/8 DP)45.8

    (69.7)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting

    Corrosion protected

    MTUMercedes-Benz0001420028A0051510001A0051510201x00001910

    MS7-505 24V 9.0kW CW INSULATED 11t 57.1(6/8 DP)45.8

    (69.7)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting

    Corrosion protected

    MTUx52417200003

    MS7-506 24V 9.0kW CW INSULATED 11t 57.1(6/8 DP)45.8

    (69.7)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting

    Corrosion protected

    MTUx52417200004

    MS7-509 24V 9.0kW CW INSULATED 11t 57.1(6/8 DP)45.8

    (69.7)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting

    Corrosion protected

    MTUx52417200010

  • www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137

    MARINE PRODUCT GUIDE 2014 STARTER MOTORS

    35 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    Sta

    rter

    Mot

    orG

    uide

    PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)

    PAR(ENG) FEATURES APPLICATION

    MS7-510 24V 9.0kW CW INSULATED 11t 57.1(6/8 DP)45.8

    (69.7)SAE3 mounting

    B+, B-, IGN

    Rotatable mounting

    Corrosion protected

    MTUx52417200011

  • www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137

  • Au

    xili

    Ar

    y eq

    uip

    men

    tZu

    sAtZ

    ger

    äte

    equ

    ipem

    ents

    Au

    xili

    Air

    eseq

    uip

    o A

    uxi

    liA

    rA

    ttr

    eZZA

    tur

    A A

    usi

    liA

    riA

    equ

    ipA

    men

    to A

    uxi

    liA

    rW

    ypo

    saże

    nie

    po

    mo

    cn

    icze

    ech

    ipa

    men

    te a

    uxi

    lia

    re

    pom

    na o

    prem

    оп

    ол

    ни

    тел

    ьн

    ое

    об

    ору

    До

    ва

    ни

    е

  • MARINE PRODUCT GUIDE 2014AUXILIARY EQUIPMENT

    www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113738

    Aux

    iliar

    y E

    quip

    men

    t Gui

    de

    Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    REGULATORS

    PART No. TYPE VOLTAGE VOLTAGE ADJUSTMENT APPLICATION CROSS-REFERENCE

    1861650 572-1 28.0V 27.0V / 28.0V / 29.0V Standard regulatorRemote fitmentAC5

    440D-24-2, 1697D520548-1, 1861600

    1861652 572-2 28.0V 27.0V / 28.0V / 29.0V Current / voltage regulation60A (max)

    Remote fitmentAC203

    548-2, 1861602

    1861654 572-3 28.0V 26.5V / 28.0V / 29.0V Current / voltage regulation80A (max)

    Remote fitmentAC203

    548-3, 1861604

    1861656 572-4 27.5V 26.5V / 27.5V / 28.5V For use with split chargingRemote fitmentAC5

    440D-24-14, 1697D548

    1861660 572-6 13.75V 13.25V / 13.75V / 14.25V Standard regulatorRemote fitmentAC5

    440D-12-2, 1697D220

    1861662 572-7M 13.75V 13.25V / 13.75V / 14.25V Standard regulator, with waterproof cover (not shown)

    Remote fitmentAC5

    440D-12-3M, 1697D230

  • www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137

    MARINE PRODUCT GUIDE 2014 AUXILIARY EQUIPMENT

    39 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com

    Aux

    iliar

    y E

    quip

    men

    t Gui

    de

    PART No. TYPE VOLTAGE VOLTAGE ADJUSTMENT APPLICATION CROSS-REFERENCE

    1861666 572-9 14.25V 13.75V / 14.25V / 14.75V Standard regulator set at 14.25v (for maintenance free batteries)

    AC5

    440D-12-13, 1697D546

    8RG2135S 8RG 14.2V V Sense WL and Sense terminals, for split charging

    Integrated fitment

    8LHA / 8LHPBLD / BLP (brushless)LBA / LBP

    8RG3078S 8RG 28.0V 27.0V - 29.0V Integrated fitment 8LHA3095R, 8LHA3096U8LHA / 8LHPBLD / BLP (brushless)

    8RL3109S 8RL 28.0V 26.8V - 29.5V Integrated fitmentReplaces 8RL3024S

    Flex-lead rectifier type 8SC’s (old style)

    Note: L-shaped circuit board interface

    8RL3024S, 8RL3021, 8RL3021-C, 8RL3022105-396, 105-251

    8RL3136S 8RL 28.0V 26.8V - 29.5V Integrated fitmentReplaces 8RL3028S

    Fixed-lead frame type 8SC’s (new style)

    Note: Plug connection

    8RL3028S

  • MARINE PRODUCT GUIDE 2014AUXILIARY EQUIPMENT

    www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113740

    Aux

    iliar

    y E