The Power of Excellence
Marine CatalogueMarine KatalogCatalogue MarineCatálogo MarinoKatalog Aplikacji MorskichCatalog Aplicaţii MaritimeKatalog Nautičkog ProgramaКаталог по морскому транспорту
2014
PP40
29Re
v: 1 (
2014
)
© 2014 Prestolite Electric Ltd www.prestolite.com
OUR COMPANYPrestolite is a rapidly expanding global company with manufacturing and distribution in North America, Europe and Asia. Having research and development facilities in each of these locations, the company combines the engineering know-how and manufacturing expertise of Lucas CAV, Leece-Neville, Butec and Motorola, to produce the best starters and alternators range in the market.
OUR PRODUCTSWe offer a complete range of Heavy, Medium and Light Duty starters and alternators covering all major European Truck, Car and Van applications as well as comprehensive Bus & Coach, Off-Highway, Agricultural, Marine and Industrial application coverage. Look out for our new Refrigeration Equipment and Marine catalogues coming soon!
OUR UNIQUE OFFERRemember that the vast majority of a range comes to you BRAND NEW. Of course this offers you OE quality levels, no availability problems due to core shortages but also the advantage of NO CORE SURCHARGES! How many times have you sold an alternator or starter only to have your profit wiped out because your supplier won’t accept your core? With Prestolite you can simply sell and forget.
OUR BRANDSEffective from mid 2007 you would have seen that all of our products are dual branded ‘Prestolite’ and ‘Leece-Neville’. We think it’s important that our customers are able to make the link between these two great brands and it’s a reminder that all ‘Leece-Neville’ products are available from Prestolite – and vice versa!
The Power of Excellence
The Power of Excellence
© 2014 Prestolite Electric Ltd www.prestolite.com
a division of Prestolite Electric Inc.
Prestolite Electric Ltd - Heavy Duty Systems
Unit 48The Metropolitan Park
12-16 Bristol Road, Greenford
Middlesex, UB6 8UP,
United Kingdom
Tel: +44 (0) 20 8231 1137
Fax +44 (0) 20 8575 9575
Prestolite Electric Ltd. Registered in England No. 1
189048
www.prestolite.com
2014 Marine Catalogue
Dear CustomerWelcome to the new addt
ion to our catalgoue range, the 2014 Marine Catalo
gue for Prestolite Electric
products.
Included in this catalogue are popular alternators a
nd starter motors used on various marine applicatio
ns,
ranging from canal barges to life saving vessels.
Also included is an Auxiliary equipment section, con
taining regulators, solenoids and external regulatio
n
conversion kits.
We strive to serve you better with this catalogue, a
nd you opinion matters to us. If you have any
suggestions on how we can further improve the inf
ormation we give you, we’d be delighted to hear fro
m
you, contact us on [email protected]
Thanks for your continued support.
Ferenc Gemesi
Sales Director – Europe, Asia, Africa
Prestolite Electric Ltd
(LH0029v3_02/14)
The Power of Excellence
© 2014 Prestolite Electric Ltd www.prestolite.com
The Power of Excellence
© 2014 Prestolite Electric Ltd www.prestolite.com
Catalogue Ref No: PP4029Issue no: 1 (03/14)
Table of Contents
A How to use this Catalogue ......................................... A-1
A Glossary of Alternator Terms ...................................... A-2
A Alternator Wiring Diagrams ......................................... A-4
A Alternator Function ..................................................... A-7
A Alternator Troubleshooting Guide ............................... A-7
A Glossary of Starter Motor Terms ................................ A-8
A Starter Motor Wiring Diagram .................................. A-9
A Starter Motor Function ............................................. A-11
A Starter Motor Troubleshooting Guide ......................... A-11
1 Alternator Guide .......................................................... 1
2 Starter Motor Guide ..................................................... 21
3 Auxiliary Equipment Guide .......................................... 37
4 Cross Reference Guide ............................................... 45
SECTION TITLE PAGE
DISCLAIMERWhile every care has been taken in compiling the information in this document, Prestolite / Leece-Neville cannot accept legal liability for any inaccuracies, omissions, or consequential damage resulting there from. Prestolite / Leece-Neville has an extensive design and development team which may alter product specification. Prestolite / Leece-Neville reserves the right to alter specifications without notice and whenever necessary to endure optimum performance from its product range.
The Power of Excellence
© 2014 Prestolite Electric Ltd www.prestolite.com
How to use this Catalogue
SECTION AThis section gives a basic understanding of the operation of the Alternator and Starter Motor within the Marine enviroment, and includes Alternator and Starter Motor function, general wiring diagrams and a Troubleshooting guide.If you have any queries that are not covered by this guide, please contact the Technical Helpline on +44 (0) 20 8231 1137.
A-1
MARINE PRODUCT GUIDE 2014ALTERNATORS
Alte
rnat
orG
uide
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113714 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No. OUTPUT POLARITYVOLT
ADJUSTROTATION
P / N TYPE FEATURES APPLICATION
8SC3157V 24V 175A INSULATED YES CW N-type J-180 mount
B+, B-, WL, ExC, AC
V adjust 26.8V - 29.5V
7/8” shaft
No pulley supplied
API MarineCaterpillar, CumminsMTU, Sabre8SC3009ZA, 110-258200833001117, 30883203629351, 2687423520958
8SC3160V 24V 150A INSULATED YES CW N-type J-180 mount
B+, B-, WL, ExC, AC
V adjust 26.8V - 29.5V
7/8” shaft
No pulley supplied
CaterpillarCummins8SC3068V, 110-4311501935, 3640732
8SC3169U 24V 100A INSULATED YES CW N-type J-180 mount
B+, B-, WL, ExC, AC
V adjust 26.8V - 29.5V
7/8” shaft
No pulley supplied
Various MarinePerkinsVolvo8SC3015U, 110-302OE52360562612
A0012303JB 24V 45A INSULATED NO BI-DIR N-type J-180 mount
B+, B-, AC
7/8” shaft
No pulley supplied
Corrosion protected
Volvo PentaCaterpillarCummins2303JB0R2698, 0R5217, 3N27023N2706, 3T6352, 3Y66915N5692, 6N5217, 6N92949G8255111640, 3015516, 3604676Rx3675126Rx
A0014727JB 24V 140A INSULATED YES CW N-type J-180 mount
B+, B-, ExC, AC
V adjust 26.0V - 32.0V
7/8” shaft
No pulley supplied
Various MarineVolvo4727JBLN4727JB
A0014740JB 24V 200A GROUNDED NO CW N-type J-180 mount
B+, B-, AC
7/8” shaft
No pulley supplied
Various Marine4740JB
PrestolitePart no.
Voltage
Alternator images
Application / Cross reference
OutputCurrent
Insulated or Earth return (Grounded)
Adjustable voltage
Direction of Rotation
P or N Type Regulation
Product features:Mounting typeTerminationsVoltage set pointShaft sizePulley infoAddtional info
MARINE PRODUCT GUIDE 2014STARTER MOTORS
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113730
Sta
rter
Mot
orG
uide
Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)
PAR(ENG) FEATURES APPLICATION
M105R3509SE 24V 7.5kW CW INSULATED 12t 46.7(8/10 DP)47.5
(66.5)SAE3 mounting
B+, B-, IGN
Rotatable mounting & relay
Cummins3102767, 39774285254108, 52564155284108M009T82671M009T82672
M105R3510SE 24V 7.5kW CW GROUNDED 10t 40(8/10 DP)47.5
(66.5)SAE1 (offset) mounting
B+, B- (Earthed), IGN
Rotatable mounting & relay
Cummins3675116, 3965282384011001503675116Rx
M105R3513SE 24V 7.5kW CW INSULATED 12t 46.7(8/10 DP)47.5
(66.5)SAE3 mounting
B+, B-, IGN
Rotatable mounting & relay
Volvo Penta3801289, 38038383586798M009T82179M009T84079
M105R3514SE 24V 7.5kW CW INSULATED 12t 44.1(M3)47.5
(66.5)SAE3 mounting
B+, B-, IGN
Rotatable mounting & relay
Mercedes-BenzInsulated version of 0001330011, 00013300200001372005, 00013720060986018370, 09860208800986022980M009T80471, M009T80472M009T80473, M009T83671M009T84771
M110R2601SE 12V 7.0kW CW INSULATED 12t 44.1(M3)47.5
(66.5)SAE3 mounting
B+, B-, IGN
Rotatable mounting & relay
Corrosion protected
Mercedes-BenzM009T70379M009T7117919011505, 190115148200084, 82004348300013
M110R2602SE 12V 7.0kW CW INSULATED 12t 46.7(8/10 DP)47.5
(66.5)SAE3 mounting
B+, B-, IGN
Rotatable mounting & relay
Corrosion protected
Volvo21019456, 21019460M9T71179MK2078MK2079VV2079
PrestolitePart no.
Voltage
Starter Motorimages
OutputPower
Rotation
Product features:Mounting typeTerminationsAdditional info
No. of teeth
Pinion at rest(Full travel)
Pinion diameter(Pinion module)
Insulated or Earth return (Grounded)
Application / Cross reference
The Power of Excellence
© 2014 Prestolite Electric Ltd www.prestolite.com
Glossary of Alternator Terms
Earth return (ER) / Grounded (G) alternators may only be fitted with a B+ (battery positive) terminal. The negative part of the electrical circuit is normally completed through the body of alternator to the vehicle, ie earthed / grounded. Also refered to as ground return. On certain vehicles a B- stud is fitted to the alternator. This is connected to the body of the alternator and must be connected to the negative earth lead where fitted.
Insulated return (IR) / Insulated ground (IG) alternator have B+ (battery positive) and B- (battery negative) terminals, ie the battery leads at the alternator are insulated from the alternator frame, ie insulated return.
B+ terminal is the battery positive connection on the alternator.
B- terminal is the battery negative terminal on the alternator.
WL is the warning lamp terminal. (L when smartreg is used.)
W or ~ or AC is the phase terminal, used for tachometer
DFM terminal communicates with the vehicle ECU and controls alternator output depending on load and system conditions.
F- is field isolation terminal. If field isolation is not required the F- must be connected to the B- terminal.
S is the sense lead / terminal. This is normally used where the voltage drop across battery leads are expected to be significant, ie long battery cable runs, where multiple battery banks and load splitters are used. This terminal monitors the voltage at the point of termination not the alternator terminals, and regulated alternator performance accordingly. This terminal is normally connected directly to the positive terminal of the charging system battery.
Alternator rotation. Alternator rotation is determined by the fan design. By design the alternator is bi-directional and can operate in either CW or CCW direction. Straight vain fans are bi-directional, see fig.1.Curved vain fans are direction specific, and a rotation direction is indicated on the fan, see fig.2. Directional fan design generally provide more efficient cooling of alternator.
Internal fan alternators are rotation specific, due to the fans being permanently attached internally to the rotor.The direction of rotation on internal fan alternators cannot be changed.Consult the drawing or Technical Helpline for specific part number rotational direction.
Note: Directional rotation when looking at front of the alternator.
Fig.1 Fig.2
A-2
The Power of Excellence
© 2014 Prestolite Electric Ltd www.prestolite.com
Glossary of Alternator Termscontinued...
Mounting configurations. Various options are available, see fig.3 - fig.6
Dual foot mount onmain mounting bracket, and single mounting on adjusted bracket.
Spool mount onmain mounting bracket, spool size from 25mm - 80 mmand single mounting on adjuster bracket.
Cradle mountThe alternator is mounted by clamping it around the alternator body.
Pad mount4 Mounting point as shown.T-mount is similar to pad mount, but with only 3 mounting point.(2 on drive end and 1 on rear end)
Fig.3 Fig.4
Fig.5 Fig.6
A-3
The Power of Excellence
© 2014 Prestolite Electric Ltd www.prestolite.com
Alternator Wiring Diagrams
The wiring diagrams shown below are typical and for reference only. For specific wiring diagrams or information, please contact the Technical Helpline on +44 (0) 20 8231 1137.
EARTH RETURN The negative circuit is supplied through the vehicle chassis and the alternator frame.
INSULATED RETURN The negative circuit is isolated from alternator frame and vehicle chassis.
Fig.7
Fig.8
A-4
The Power of Excellence
© 2014 Prestolite Electric Ltd www.prestolite.com
Alternator Wiring Diagramscontinued...
FIELD ISOLATION This option is supplied with a F- terminal, for use with battery / field isolator switch.
Fig.9
Battery
+-
W (Tacho)
L (Lamp)
DFM (Field monitor)
S (Sense)
15 (Ignition)
Secondary B+
NCB2 TYPE This is an earth return alternator.The vehicle harness plugs directly into the regulator connection. The regulator may interact with the vehicle ECU. These regulators are not interchangeable as some functions vary depending on application. Ensure the correct regulator / alternator is specified.
Fig.10
A-5
The Power of Excellence
© 2014 Prestolite Electric Ltd www.prestolite.com
Multiple applications are common placed where high current demand is required.It is important that the regulated voltage of the alternators used are matched, failure to do so would cause one of the alternators to shutdown. In addition it also important that the lenght of cables for the two alternators be kept the same to ensure that the voltage drops in the lines are identical (or as close as possible). The voltage drops must not exceed 1.0V.
Alternator Wiring Diagrams
o o
Battery+-
WL WL
To tacho
o oIgnitionIgnition
TWIN APPLICATION Two (or more) alternators paired to deliver high current output. Fig.11
External regulators / Battery management systems.Many vessels use complex battery management systems to charge multiple battery banks. This is done by linking into the alternator field brush to control the field current. For wiring instructions, please consult with battery management system supplier.External regulation conversion kits are available for the 8LHA, 8LHP, BLD, BLP, LBA, LBP, MDA, MDA alternators, please see Auxiliary Component section.
Not all alternators are suitable for use with split charging systems. Split charging systems can prevent the alternator from sensing battery voltage or give a fasle battery voltage reading. Ideally an alternator with a sense (S) terminal must be used. See fig.8.
Please note that external regulation systems and battery management systems might operate the alternator outside of its intended design parameters and could invalidate warranty.
A-6
The Power of Excellence
© 2014 Prestolite Electric Ltd www.prestolite.com
Alternator Function
The alternator essentially consists of 3 components; the rotor / stator assy, the rectifier and the regulator.
The rotor and stator assembly utilised basic physics to generate electricity by rotating an electromagnetic field (rotor) within a series of windings (stator). This produces a 3 phase alternating current (AC) output from the stator.
The AC output is not suitable for DC system. The rectifier utilised a series of diodes to convert the original AC output to a direct current (DC) output, which is supplied to the vehicle loads and batteries.
The regulator controls the output of the alternator by increasing and decreasing the magnetic field of the rotor as required.
The alternator must be able to supply current to all required loads and have sufficient capacity to charge the vehicle batteries.
Most vehicles have some kind of warning light function that indicates when the alternator is not functioning as expected. This warning light will be illuminated when the ignition is switched on, but engine not started.Once the engine has been started and is idling the warning light go out. This warning light circuit also serves as an excitation for the alternator, supplying approx 2.0-2.8W. The alternator will not charge if the warning light is not connected.
For alternator wiring details refer to Fig.7 - to Fig.11. These illustrations are for reference only, please contact the Technical Helpline on +44 (0) 20 231 1137 for specific wiring information.
Problem Possible cause Action
No warning light when switched on
Flat batteryCheck battery, charge in accordance with battery manufacturer’s specification if required.
Blown warning light bulb or fuse Check warning light bulb or fuse.
Poor / incorrect connections Check wiring and connections.
Warning light does not go out when engine idling
Poor / incorrect connections Check wiring and connections.
Warning light shorted to earth Check wiring and connections.
Excessive voltage drop in ignition circuit
Check wiring and connections.
Faulty rectifier Check rectifier circuit and diodes.
Faulty regulator or alternator Remove and test regulator and alternator.
Low outputSlipping drive Check Pulley, belts or coupling.
Faulty regulator or alternator Remove and test regulator and alternator.
Flickering warning light
Slipping drive Check Pulley, belts or coupling.
Volt drop in sensing line Check wiring and connections.
Faulty regulator or alternator Remove and test regulator and alternator.
Battery overcharging, high alternator output voltage
Faulty regulator Remove and test regulator.
Alternator Troubleshooting Guide
A-7
The Power of Excellence
© 2014 Prestolite Electric Ltd www.prestolite.com
Glossary of Starter Motor Terms
Earth return (ER) starter motors will only be fitted with a B+ (battery positive) terminal. The negative part of the electrical circuit is completed through the body of starter motor and the vehicle chassis.
Insulated return (IR) starter motors have B+ (battery positive) and B- (battery negative) terminals, ie the battery leads at the alternator are insulated from the vehicle chassis.
B- terminal is the battery negative terminal on the alternator or starter motor.
B+ / Terminal 30 is the battery positive connection terminal on starter motor, normally found on solenoid.
SW / Terminal 50 is the positive feed connection to the solenoid.
Terminal 15a is a cold start terminal.
Rotation is generally in a clockwise (CW) direction, when looking at the front of the starter motor, however there are counter clockwise CCW applications.
Pinion at rest (PAR) position is the meassured distance between the mounting flange and the front face of pinion when the starter is not energised. (See Fig. 9)
Pinion full travel position is the measured distance between the mounting flange and the front face of the pinion when the starter motor is energised. (See Fig.9)
Fig.12 Fig.13
Fig.14
CW CCW
A-8
The Power of Excellence
© 2014 Prestolite Electric Ltd www.prestolite.com
Glossary of Starter Motor Termscontinued...
Solenoid / Switch is the part of the starter that activates the engagement / disengagement of the pinion/drive to the vehicle ringgear/flywheel, and also connects the battery to the motor via contact switch.
Mounting configurations. Several options are available, the most common are SAE1 and SAE3.See fig.15 & fig.16.
Starter drive is the mechanism linking the starter rotational force and the vehicle engine, via ring gear/flywheel.This incorporates an overrun device to protect the motor in the event that the starter is not released when the engine has starter.
The pinion is the geared component on the drive that interfaces with the ring gear / flywheel.
The wiring diagrams shown below are typical and for reference only. For specific wiring diagrams or information, please contact the Technical Helpline on +44 (0) 20 8231 1137
The fitment of a Starter Lockout unit is recommended to prevent energising of starter motor whilst engine is running.
SAE1The 3 mounting holes are on a PCD of 127mm, spaced at 90°
SAE3The 3 mounting holes are on a PCD of 146mm, equi-spaced at 120°
Fig.15 Fig.16
Starter Motor Wiring Diagrams
Fig.17
EARTH RETURN The negative circuit is supplied through the vehicle chassis and the starter motor frame.
A-9
The Power of Excellence
© 2014 Prestolite Electric Ltd www.prestolite.com
Starter Motor Wiring Diagramscontinued...
AUXILIARY SOLENOID Used on gear reduction starters to limit current draw during soft start operation.
INSULATED RETURN The negative circuit is isolated from starter motor frame and vehicle chassis.
Fig.18
Fig.19
NOTE: Do not disconnect or bypass the control relay (if fitted) on the starter motor.
A-10
The Power of Excellence
© 2014 Prestolite Electric Ltd www.prestolite.com
Starter motor FunctionThe basic components of the starter motor is the solenoid (switch), the motor, the shift assembly and the drive assembly.
When the circuit is energised, via the start button, the solenoid is activated into 1st stage contact, which engages thelinkage system in the shift assembly and in turn moves the drive towards the ringgear. At this point a small current will flow through the motor causing a slow rotation of the motor and drive, this is to allow for the pinion to engage the ringgear correctly. Once the pinion has engaged the ringgear, the solenoid 2nd contact will be activated and full current will be supplied to the motor, causing the motor to rotate at full speed and torque, cranking the engine via the drive and ringgear.
Once the engine has started and the engine speed is higher than that of the starter motor the overrunning protection function of the drive will prevent the engine accelerating the starter motor. As soon as the engine has started the driver / operator should release the starter button.Please note that the over-run clutch protection function will be damaged by wreckless & prolonged over-cranking.
Gear-reduction starter motors are becoming increasingly popular due to compact design. These starters operatare in the same manner, but is fitted with a small gearbox between the motor and the shift / drive assembly.
For starter motor wiring details refer to Fig.17, Fig.18 and Fig.18. These illustrations are for reference only, please contact the Technical Helpline on +44 (0) 20 8231 1137 for specific wiring information.
Starter motor Troubleshooting GuideProblem Possible cause Action
Starter does not engage
Flat batteryCheck battery, charge in accordance with battery manufacturer’s specification if required.
Poor / incorrect connections Check wiring and connections.
Faulty ignition or start buttonCheck battery voltage is available at the starter motor solenoid terminals when ignition / buton operated.
Faulty solenoid / auxiliary solenoid Test operation of the solenoid / auxiliary solenoid.
Faulty starter Remove and rectify.
Starter engages but does not crank the engine
Flat batteryCheck battery, charge in accordance with battery manufacturer’s specification if required.
Poor / incorrect connections Check wiring and connections.
Excessive volt drop in main cablesCheck voltage drop by measuring voltage between starter terminals and battery terminals. Also, check earth circuit when ignition / button is operated.
Incorrect starter timing Remove and rectify.
Faulty starter Remove and rectify.
Starter engages but cranks slowly
Flat batteryCheck battery, charge in accordance with battery manufacturer’s specification if required.
Poor / incorrect connections Check wiring and connections.
Excessive volt drop in main cablesCheck voltage drop by measuring voltage between starter terminals and battery terminals. Also, check earth circuit when ignition / button is operated.
Faulty solenoid Remove and replace.
Faulty starter Remove and rectify.
Starter spins against flywheel
Spacer or mounting flange unneccessary Check if spacer is required and discard if unnecassary
Incorrect starter timing Remove and rectify.
Faulty starter Remove and rectify.
A-11
The Power of Excellence
© 2014 Prestolite Electric Ltd www.prestolite.com
Notes:
The Power of Excellence
© 2014 Prestolite Electric Ltd www.prestolite.com
Notes:
Alt
ern
Ato
rs
Gen
erA
tor
enA
lter
nA
teu
rs
Alt
ern
Ad
or
es
Alt
ern
Ato
ri
Alt
ern
Ato
ry
Alt
ern
Ato
Ar
eГе
нер
ато
ры
MARINE PRODUCT GUIDE 2014ALTERNATORS
Alte
rnat
orG
uide
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 11372 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No. OUTPUT POLARITYVOLTAGEADJUST
ROTATIONP / N TYPE FEATURES APPLICATION
858882 24V 55A GROUNDED NO CW N-type 80mm Spool mount
Earth return (B- stud)
B+, B-, WL, AC
17mm shaft
No pulley supplied
Scania0120469569, 01204696430120469763, 01204698070120469900, 01204699590120469960, 0986032720 19025102, DRA2720CA155IR, CA227IR, CA749IR LRB104
860053 24V 75A INSULATED NO CW N-type J-180 mount
B+, B-, WL, AC
7/8” shaft
No puley supplied
Can use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S(TSB-1112)
Various MarineCummins8598663284848DRA3596
860141 24V 27A GROUNDED NO CW N-type Swung mount
B+, B-, WL
17mm shaft
No pulley supplied
Fiat, Iveco0120489410/2/3, 0120489612, 0120489638/9 0120489661,01204896820120489792/3/40120489795/60986031340, 098603219119025044, DRA1340CA212IR, LRA839, LRB300
1268110M 12V 75A INSULATED NO CW N-type 3” Spool mount
B+, B-, WL, S, AC
Field isolation (F-)
3/4” shaft
No pulley supplied
Corrosion protected
Various MarineCummins3910565, 3975138
1268600M 24V 55A INSULATED NO CW N-type 3” Spool mount
B+, B-, WL, S, AC
Field isolation (F-)
3/4” shaft
No pulley supplied
Corrosion protected
Various MarineDorman, Perkins, RNLI702178OD18580D14809
1268650M 24V 55A INSULATED NO CW N-type 3” Spool mount
B+, B-, WL, S, AC
Field isolation (F-)
3/4” shaft
No pulley supplied
Corrosion protected
Various MarineCummins3910566, 3975139
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137
MARINE PRODUCT GUIDE 2014 ALTERNATORS
3
Alte
rnat
orG
uide
Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No. OUTPUT POLARITYVOLT
ADJUSTROTATION
P / N TYPE FEATURES APPLICATION
1282030M 24V 240A INSULATED NO BI-DIR N-type Twin lugs
B+ (x2), B-, WL, AC
Special build
30mm shaft
No pulley supplied
Corrosion protected
Various MarineRNLI, VolvoD14849
1287000 24V 600A GROUNDED NO BI-DIR Swung mount
B+ (x2), B-, WL, IGN, S, AC, DFM
Special build
30mm shaft
No pulley supplied
New releaseAB210R type
20100527 12V 65A GROUNDED NO BI-DIR N-type Swung mount
B+, WL
17mm shaft
4pk, 59mm pulley
Various Marine0986038401DRA3199JA756IRLRA527
20110134 12V 70A GROUNDED NO CW N-type 56mm Spool mount
B+, WL, AC
17mm shaft
No pulley supplied
Various MarineVolvo0120488114, 01204881850120489069, 01204890700120489183, 01204893090986032930, 09860329400986037890DRA2930, CA231IRCA238IR, LRB134
20110290 12V 70A GROUNDED NO BI-DIR N-type Swung mount
B+, WL, AC
Europlug connection
17mm shaft
No pulley supplied
Various MarinePerkins2871A154, 2871A160DRA3667LRB290
20110293 12V 65A GROUNDED NO CW N-type 56mm Spool mount
B+, WL, AC
17mm shaft
No pulley supplied
Various Marine0120339512/3, 01203395320120339545, 01204891560120489317, 0120489703/40986030110, 0986033320DRA3445CA522IR, CA734IR, CA915IRLRA621, LRB293
MARINE PRODUCT GUIDE 2014ALTERNATORS
Alte
rnat
orG
uide
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 11374 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No. OUTPUT POLARITYVOLT
ADJUSTROTATION
P / N TYPE FEATURES APPLICATION
20130133 1(2V 70A GROUNDED NO CW N-type 56mm Spool mount
B+, WL, AC
17mm shaft
No pulley supplied
Various MarineDeutz, Iveco, KHD0120300552, 01203395140120339531, 01204897560986030130, 0986031330DRA0130CA340IR, CA745IR, CA76IRLRA584
20130134 24V 35A GROUNDED NO CW N-type 56mm Spool mount
B+, WL, AC
17mm shaft
No pulley supplied
Various MarineDeutz, Iveco, KHD0120488153, 01204882340120488283, 01204897310986031320, 0986035910DRA1320, DRA5910CA369IR, CA702IR
20130177 12V 35A GROUNDED NO CW Swung mount
B+, B-, WL, AC
Single V, 72mm pulley
Yanmar12140077201, 1240807720112817177200, 12827077200LR12015C, LR135105LR135126, LR13521LR13558(B), LR13591
20130178 12V 51A GROUNDED NO BI-DIR 2” Spool mount
B+, B-, WL, Exc, S, AC
17mm shaft
Single V, 73mm pulley
Mercruiser, YamahaJA787IR,10140010A000B0431, A000B0471KAC155513, AR150CAAR150DA, AR155CA, M40473TA0B09601
20130179 12V 65A GROUNDED NO BI-DIR 2” Spool mount
B+, B-, WL, Exc, S, AC
17mm shaft
6pk, 63mm pulley
MercruiserJA1169IR,A000B0331, AC155603AC155616, AC165610AC165616/7, AR150AAAR150AR, AR150BAM50924, M59207, 8171191/2805884P/T, 807652/3
20130204 12V 65A GROUNDED NO BI-DIR 2” Spool mount
B+, B-, WL, Exc, S, AC
17mm shaft
Single V, 73mm pulley
Various MarinePleasurecraftVolvoAC155614, AC165618M56750, 3856600RA0970063857813, 3860171, 3856600638575619
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137
MARINE PRODUCT GUIDE 2014 ALTERNATORS
5
Alte
rnat
orG
uide
Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No. OUTPUT POLARITYVOLT
ADJUSTROTATION
P / N TYPE FEATURES APPLICATION
20130207 12V 65A GROUNDED NO CW N-type Swung mount
B+, B-, WL
17mm shaft
Single V, 90mm pulley
Various MarineMermaid Marine Engines0986030970, 09860332300986033880, 0986035630/10986036230
20130211 24V 45A GROUNDED NO CW N-type 2” Spool mount
B+, WL, AC
17mm shaft
No pulley supplied
Cummins3020678, 32843913284392, 39112473920678(Rx)0120488206, 01204882940120489071, 0120489481
20150113 12V 90A INSULATED NO BI-DIR N-type 2” Spool mount
B+, B-, WL, AC
17mm shaft
Single V, 64mm pulley
Corrosion protected
Volvo Penta11203416, AAK4352, IA120210127
20150114 24V 80A INSULATED NO BI-DIR* N-type 2” Spool mount
B+, B-, WL, AC
17mm shaft
No fan or pulley supplied
Corrosion protected
API MarineVolvo Penta
20150115 24V 65A INSULATED NO BI-DIR* N-type 2 Lug mount
B+, B-, WL, AC
17mm shaft
No fan or pulley supplied
Corrosion protected
Various MarineIveco Marine engineScania0120468132, 098604407019025115571440, 1358638, 1397038
20150116 24V 80A INSULATED NO BI-DIR* N-type 80mm Spool mount
B+, B-, WL, AC
17mm shaft
No fan or pulley supplied
Corrosion protected
Various MarineCumminsMercedes / MAN engine3283780A007154810201177464
MARINE PRODUCT GUIDE 2014ALTERNATORS
Alte
rnat
orG
uide
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 11376 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No. OUTPUT POLARITYVOLT
ADJUSTROTATION
P / N TYPE FEATURES APPLICATION
47020067 12v 70A INSULATED NO CW Swung mount
B+, B-, WL, AC
17mm shaft
No pulley supplied
Corrosion protected
90A version = 66021535
24V/60A version = 66021532
API MarineLister PetterSabre Marine20024, 362023442871A60240082LRA0117866021587
47020069 12v 70A INSULATED NO CW Swung mount
B+, B-, WL, AC
17mm shaft
No pulley supplied
Corrosion protected
Various MarineLister PetterSabre Marine 3620234966021588
66021126M 12V 60A INSULATED NO BI-DIR N-type 2 Lug mount
B+, B-, WL, AC
17mm shaft
Single V, 65mm pulley
90A version = 66021590M
Various MarineSole DieselCA1550IRNAB900MPBNAM10013817100
66021151M 12V 70A INSULATED NO BI-DIR N-type 2” Spool mount
B+, B-, WL, AC
17mm shaft
Single V, 64mm pulley
Corrosion protected
90A version = 20150113
API MarineVolvo Penta
66021151MS 12v 70A INSULATED NO CW N-type 2” Spool mount
B+, B-, WL, S, AC
17mm shaft
No pulley supplied
Volvo Penta436378, 436638, 436676439067, 439181, 439185518039, 2541191, 25414512541827, 2927120A13N186M, A13N2858720195, 3803146438032603
66021153B 12V 70A GROUNDED NO BI-DIR N-type 56mm Spool mount
B+, WL, AC
17mm shaft
Single V, 64mm pulley
Various MarineNAB902, NAB904CA1467IR, CA1479IR
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137
MARINE PRODUCT GUIDE 2014 ALTERNATORS
7
Alte
rnat
orG
uide
Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No. OUTPUT POLARITYVOLT
ADJUSTROTATION
P / N TYPE FEATURES APPLICATION
66021414 12V 70A GROUNDED NO CW N-type 56mm Spool mount
B+, WL, AC
17mm shaft
Single V, 65mm pulley
Various Marine0986030870, 09860308800986030890, 0986034650/1LRA207, LRA313, LRA346LRA786, LRA819, LRA886LRB131
66021491 24V 55A INSULATED NO BI-DIR N-type 3” Spool mount
B+, B-, WL, AC
Field isolation (F-)
3/4” shaft
8pk, 82mm pulley
Various Marine108026, 108275, 858948859444, 859876, 858948ZA302441LNA40241, LNA40249
66021507 24V 55A INSULATED NO BI-DIR N-type 3” Spool mount
B+, B-, WL, AC
Field isolation (F-)
3/4” shaft
No pulley supplied
Various MarineCumminsPerkins550117, 3250087, 32567593279007, 3964745 3256759Rx 2871A682880624Z, 880626Z, 880627Z880628Z, 880629Z, 880648Z
66021532 24V 60A INSULATED NO BI-DIR N-type 2 Lug mount
B+, B-, WL, AC
17mm shaft
Single V, 80mm pulley
Corrosion protected
12V version = 47020067
Sabre MarinePerkinsVolvo35362, 192792871A651, 2871C2023976608, 811309747020061, 47020083 47020090, 66021593PBNAM102, PBNAM108
66021535 12V 90A INSULATED NO BI-DIR N-type 2 Lug mount
B+, B-, WL, AC
17mm shaft
Corrosion protected
70A version = 47020067
Lister PetterPerkinsSabre Marine35361, 400822871A145, 2871A1522871A157, 2871A60236202344
66021543 12V 60A GROUNDED NO BI-DIR Swung mount
B+, WL, AC
15mm shaft
Single V, 68mm pulley
Various MarinePerkins2871A122, 2871A139LRA278, LRA360, LRA582
MARINE PRODUCT GUIDE 2014ALTERNATORS
Alte
rnat
orG
uide
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 11378 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No. OUTPUT POLARITYVOLT
ADJUSTROTATION
P / N TYPE FEATURES APPLICATION
66021583 12V 70A GROUNDED NO CW N-type 27mm Spool mount
B+, B-, WL, AC
17mm shaft
Single V, 80mm pulley
Aqua CultureLRA2209AR2510K, 9AR2513F9AR2514F, 9AR2553K9AR2556K, 9AR2566K9AR2856K
66021590M 12V 90A INSULATED NO BI-DIR N-type 2 Lug mount
B+, B-, WL, AC
17mm shaft
Single V, 65mm pulley
24V version = 66021623M
Various Marine113152NAB9000M
66021623M 24V 60A INSULATED NO BI-DIR N-type Swung mount
B+, B-, WL, AC
17mm shaft
Single V, 65mm pulley
Corrosion protected
12V version = 66021590M
Various MarineNAB9001M
66021626A 24V 55A INSULATED NO BI-DIR N-type 3” Spool mount
B+, B-, WL, AC
Field isolation (F-)
3/4” shaft
No pulley supplied
Various Marine702175, 702183, 702184702185, 702186859450Z, A402420, A402426LNA40244, LNA4024566021544GB, 66021616/A
66021627A 24V 55A INSULATED NO BI-DIR N-type 3” Spool mount
B+, B-, WL, AC
Field isolation (F-)
3/4” shaft
No pulley supplied
Various MarineCummins3332215, 3631678, 36347784101372859617, 66021496, LNA40247
66021636 12V 65A GROUNDED NO BI-DIR N-type Swung mount
B+, WL, AC
17mm shaft
Single V, 72mm pulley
Various MarineFord,Perkins2871A141, 2871A1472871A148, 2871A1532871A154, 2871A1632871A165, 2871C1042871K148
W
AUX
W
AUX
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137
MARINE PRODUCT GUIDE 2014 ALTERNATORS
9
Alte
rnat
orG
uide
Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No. OUTPUT POLARITYVOLT
ADJUSTROTATION
P / N TYPE FEATURES APPLICATION
66021637 12V 65A GROUNDED NO BI-DIR N-type Swung mount
B+, WL, AC
17mm shaft
Single V, 72mm pulley
Various MarineFord,Perkins9AR2562, 9AR2569 9AR2651D, 9AR26539AR2706G2871A142, 2871A1612871D031, 3907749
8AR3200G 24V 40A INSULATED NO BI-DIR N-type 2” Spool mount
B+, B-, WL, S, ExC, AC
17mm shaft
No fan or pulley supplied
CumminsHobartWhite110-4623604478, 39114623604478Rx, EE9028402505505, 402505506
8HC2023KS 12V 51A INSULATED NO BI-DIR N-type 1” Spool mount
B+, B-, AC
5/8” shaft
No pulley supplied
Can use regulator +ve lead as sense lead
Corrosion protected
Caterpillar110-284712096, 0R3654, 6T13967T2096
8HC2027PAS 12V 72A INSULATED NO BI-DIR N-type 2 Lug mount
B+, B-, WL, ExC, AC
5/8” shaft
Double V,
Can use regulator +ve lead as sense lead
Various MarineVolvo110-5385034-110538LN110538
8HC3022FS 24V 35A INSULATED NO BI-DIR N-type 1” Spool mount
B+, B-, AC
5/8” shaft
No pulley supplied
Can use regulator +ve lead as sense lead
Corrosion protected
API MarineCaterpillarMotorola110-28520150, 3T1395, 6P13956T1345, 6T1395, 7T2095OR3653
8HC3026G 24V 42A INSULATED NO BI-DIR N-type 2” Spool mount
B+, B-, S, ExC, AC
5/8” shaft
No pulley supplied
Various Marine110-392100032214xx-L124714
MARINE PRODUCT GUIDE 2014ALTERNATORS
Alte
rnat
orG
uide
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113710 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No. OUTPUT POLARITYVOLT
ADJUSTROTATION
P / N TYPE FEATURES APPLICATION
8LHA2070VF 12V 160A INSULATED NO CW N-type J-180 mount
B+, B-, AC
7/8” shaft
No pulley supplied
Can use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S(TSB-1112)
Various MarineCumminsNapa MarineSabreVolvo3604670Rx, 3675200Rx3675158Rx, 3675218Rx3675236Rx407394, 34416 849747, 802010039
8LHA2071VA 12V 160A INSULATED NO CW N-type J-180 mount
B+, B-, WL, AC
7/8” shaft
No pulley supplied
Can use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S(TSB-1112)
Various Marine110-555IJHO10459040, 1045904810459111, 1901010419010120, 1901012419010125, 1901012919010145, 1901014719010178, 19010196
8LHA3071P 24V 75A INSULATED YES CW N-type J-180 mount
B+, B-, AC
7/8” shaft
No pulley supplied
Can use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S(TSB-1112)
CaterpillarCumminsPerkinsSabre MarineVolvoL2E31, 9011707079OD20382, 39206173920618, 39355313603848Rx, 3603853Rx3675201Rx, 3675212Rx
8LHA3096U 24V 110A INSULATED YES CW N-type J-180 mount
B+, B-, WL, AC
7/8” shaft
No pulley supplied
Corrosion protectedCan use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S (TSB-1112)
CumminsE.P. BarrusSabre marineVolvo3072483, 34006984078701, 3604685Rx3604687Rx, 3675103Rx3675104Rx27175, 9012724607
8LHA3159R 24V 95A INSULATED NO CW N-type 3” Spool mount
B+, B-, WL, AC
7/8” shaft
No puley supplied
Can use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S(TSB-1112)
Various MarineCummins3283806, 3975135,860323,DRA3795,CA4003
8LHC2010Z 12V 160A INSULATED NO BI-DIR N-type J-180 mount
B+, B-, AC
7/8” shaft
No pulley supplied
Corrosion protected
Volvo Penta110-2543969571, 802010048F2HS10346BA
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137
MARINE PRODUCT GUIDE 2014 ALTERNATORS
11
Alte
rnat
orG
uide
Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No. OUTPUT POLARITYVOLT
ADJUSTROTATION
P / N TYPE FEATURES APPLICATION
8MH2003KS 12V 51A INSULATED NO BI-DIR N-type 1” Spool mount
B+, B-, AC
Unregulated
5/8” shaft
No pulley supplied
Corrosion protected
Caterpillar110-1332N7759, 2N77957418
8MR2049KA 12V 51A INSULATED NO BI-DIR N-type 2” Spool mount
B+, B-, WL, ExC, AC
5/8” shaft
No pulley supplied
Can use regulator +ve lead as sense lead
Corrosion protected
Various Marine110-5177495, 2102508EM2007K8EM2007KA8MR2049K
8MR2050FA 12V 37A INSULATED NO BI-DIR N-type 1” Spool mount
B+, B-, WL, ExC, AC
5/8” shaft
No pulley supplied
Can use regulator +ve lead as sense lead
Corrosion protected
CumminsMotorola110-5323675140Rx2103488EM2001FA8EM2001FAS8MR2050F
8MR2058PA 12V 72A INSULATED NO BI-DIR N-type 2” Spool mount
B+, B-, WL, ExC, AC
Can use regulator +ve lead as sense lead
Corrosion protected
CumminsVolvo110-5211911600, LN11052174892102368MR2058P
8MR2069TA 12V 90A INSULATED YES BI-DIR N-type 2” Spool mount
B+, B-, ExC, AC
17mm shaft
No pulley supplied
Can use regulator +ve lead as sense lead
Corrosion protected
Various Marine110-60230347321787691
8MR2070TA 12V 90A INSULATED YES BI-DIR N-type 1” Spool mount
B+, B-, AC
5/8” shaft
No pulley supplied
Can use regulator +ve lead as sense lead
Corrosion protected
API MarineMercuryMotorola110-60379635182298220096
MARINE PRODUCT GUIDE 2014ALTERNATORS
Alte
rnat
orG
uide
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113712 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No. OUTPUT POLARITYVOLT
ADJUSTROTATION
P / N TYPE FEATURES APPLICATION
8MR2091KSS 12V 51A INSULATED NO CW N-type 2” Spool mount
B+, B-, WL, S, ExC, AC
5/8” shaft
Corrosion protected
Various MarineMercuryVolvo17399, 78403, 78403A209854650, 3853853
8MR2092L 12V 65A INSULATED NO CW N-type 2” Spool mount
B+, B-, WL, S, ExC, AC
5/8” shaft
Single V, 66.5mm
Corrosion protected
Various Marine110-483824-0049
8MR2093L 12V 65A INSULATED NO CW N-type 2” Spool mount
B+, B-, WL, S, ExC, AC
5/8” shaft
Single V, 66.5mm
Corrosion protected
Various Marine110-484
8MR2175F 12V 37A INSULATED NO CW N-type 1” Spool mount
B+, B-, WL, S, ExC, AC
5/8” shaft
No pulley supplied
Corrosion protected
Various Marine110-6993675146Rx110399, 8EK2008F8EK2008FA, 8EK2008FB8EK2008FC, 8EK2008FD8EK2009FA, 8EK2009FB8EK2009FC
8MR2185L 12V 65A INSULATED NO CW N-type 1” Spool mount
B+, B-, S, ExC, AC
5/8” shaft
No pulley supplied
Corrosion protected
Misc Marine3675147Rx8EK2007N, 8EK2007NA8EK2007NB, 8EK2007NC8EK2007ND, 8EK2010NA8EK2010NB, 8EK2010NC8EK2010ND, 8EK2012NA8EK2012NB7480, 210407
8MR2198L 12V 65A INSULATED NO BI-DIR N-type 1” Spool mount
B+, B-, ExC, AC
5/8” shaft
No pulley supplied
Can use regulator +ve lead as sense lead
Corrosion protected
CumminsMotorolaVolvoYamaha
8EM2012N, 8EM2012NA8EM2012NAS
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137
MARINE PRODUCT GUIDE 2014 ALTERNATORS
13
Alte
rnat
orG
uide
Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No. OUTPUT POLARITYVOLT
ADJUSTROTATION
P / N TYPE FEATURES APPLICATION
8MR2199KS 12V 51A INSULATED NO BI-DIR N-type 1” Spool mount
B+, B-, WL, ExC, AC
5/8” shaft
No pulley supplied
Can use regulator +ve lead as sense lead
Corrosion protected
Chris CraftMotorolaPleasure Craft110-6560665000337350, 7384, 7404, 7423RA0970048EM2005K, 8EM2005KA8MA2004K
8MR2401UA 12V 105A INSULATED YES BI-DIR N-type 1” Spool mount
B+, B-, AC
5/8” shaft
No pulley supplied
Can use regulator +ve lead as sense lead
Corrosion protected
Various Marine110-567, 110-534
8MR3188K 24V 55A INSULATED NO CW N-type 1” Spool mount
B+, B-, AC
17mm shaft
No pulley supplied
Can use regulator +ve lead as sense lead
Corrosion protected
Various MarineCaterpillar110-55711280321547993
8MR3301G 24V 40A INSULATED NO BI-DIR N-type 2” Spool mount
B+, B-, WL, S, ExC, AC
17mm shaft
No pulley supplied
Corrosion protected
Cummins39105758EK3006GA, 8EM3001GA
8MR3404G 24V 40A INSULATED NO BI-DIR N-type 1” Spool mount
B+, B-, ExC, AC
5/8” shaft
No pulley supplied
Can use regulator +ve lead as sense lead
Corrosion protected
CumminsMotorolaWhiteYamaha110-684C0191157000MH24N901 MH24N901B8EM3003G, 8EM3003GA402500106
8SC3133U 24V 100A INSULATED YES CW N-type J-180 mount
B+, B-, WL, ExC, AC
V adjust 26.8V - 29.5V
7/8” shaft
No pulley supplied
CumminsE.P. BarrusSabreVolvo8SC3014U, 110-2982720871RDG20198933279220, 263102557832, 25578329LN110298
MARINE PRODUCT GUIDE 2014ALTERNATORS
Alte
rnat
orG
uide
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113714 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No. OUTPUT POLARITYVOLT
ADJUSTROTATION
P / N TYPE FEATURES APPLICATION
8SC3157V 24V 175A INSULATED YES CW N-type J-180 mount
B+, B-, WL, ExC, AC
V adjust 26.8V - 29.5V
7/8” shaft
No pulley supplied
API MarineCaterpillar, CumminsMTU, Sabre8SC3009ZA, 110-258200833001117, 30883203629351, 2687423520958
8SC3160V 24V 150A INSULATED YES CW N-type J-180 mount
B+, B-, WL, ExC, AC
V adjust 26.8V - 29.5V
7/8” shaft
No pulley supplied
CaterpillarCummins8SC3068V, 110-4311501935, 3640732
8SC3169U 24V 100A INSULATED YES CW N-type J-180 mount
B+, B-, WL, ExC, AC
V adjust 26.8V - 29.5V
7/8” shaft
No pulley supplied
Various MarinePerkinsVolvo8SC3015U, 110-302OE52360562612
A0012303JB 24V 45A INSULATED NO BI-DIR N-type J-180 mount
B+, B-, AC
7/8” shaft
No pulley supplied
Corrosion protected
Volvo PentaCaterpillarCummins2303JB0R2698, 0R5217, 3N27023N2706, 3T6352, 3Y66915N5692, 6N5217, 6N92949G8255111640, 3015516, 3604676Rx3675126Rx
A0014727JB 24V 140A INSULATED YES CW N-type J-180 mount
B+, B-, ExC, AC
V adjust 26.0V - 32.0V
7/8” shaft
No pulley supplied
Various MarineVolvo4727JBLN4727JB
A0014740JB 24V 200A GROUNDED NO CW N-type J-180 mount
B+, B-, AC
7/8” shaft
No pulley supplied
Various Marine4740JB
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137
MARINE PRODUCT GUIDE 2014 ALTERNATORS
15
Alte
rnat
orG
uide
Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No. OUTPUT POLARITYVOLT
ADJUSTROTATION
P / N TYPE FEATURES APPLICATION
A0014742JB 24V 200A GROUNDED NO CW N-type J-180 mount
B+, B-, ExC, AC, Rx
Multipower unit
7/8” shaft
No pulley supplied
Various Marine4742JB
A0014980PGH 24V 200A INSULATED NO CW N-type Pad mount
B+, B-, AC
7/8” shaft
No pulley supplied
MTUx51621300001x57521300020A0014980PAHA0014980PAH-P
A0014989PGH 24V 190A INSULATED NO BI-DIR N-type Pad mount
B+, B-, D+, AC
7/8” shaft
No pulley supplied
MTU, MANx57521300025x5162130003451261017312A0014989PAHA0014989PAH-1A0014989PAH-2
AVi136A2004 12V 125A GROUNDED NO CW Swung mount
B+, B-, WL, AC
20mm shaft
6pk, 56mm pulley
Various Marine
AVi136A3002 24V 75A GROUNDED NO CW Swung mount
B+, B-, WL, AC
20mm shaft
8pk, 50mm pulley
Various Marine
AVi1441F11 12V 150A GROUNDED NO CW Swung mount
B+, B-, WL, AC
20mm shaft
4pk, 60mm pulley
Various Marine
MARINE PRODUCT GUIDE 2014ALTERNATORS
Alte
rnat
orG
uide
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113716 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No. OUTPUT POLARITYVOLT
ADJUSTROTATION
P / N TYPE FEATURES APPLICATION
AVi1442A21 24V 105A GROUNDED NO CW Swung mount
B+, B-, WL, AC
20mm shaft
8pk, 50mm pulley
Various Marine
AVi144B2008 12V 150A GROUNDED NO CW Swung mount
B+, B-, WL, AC
20mm shaft
Double V, 75mm pulley
Various Marine
AVi144B2018 12V 150A GROUNDED NO CW Swung mount
B+, B-, WL, AC
20mm shaft
6pk, 50mm pulley
Various MarineE.P. BarrusRDG20110201
AVi144C2006 12V 150A GROUNDED NO CW Swung mount
B+, B-, WL, AC
20mm shaft
8pk, 55mm pulley
Various Marine
AVi144C3002 24V 105A GROUNDED NO CW Swung mount
B+, B-, WL, AC
20mm shaft
8pk, 55mm pulley
Various Marine
AVi144N1C 24V 105A GROUNDED NO CW Swung mount
B+, B-, WL, AC
20mm shaft
No pulley supplied
Various Marine
B +
W
D+
D+ E
B +
E
B +
W
D+
D+ E
B +
E
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137
MARINE PRODUCT GUIDE 2014 ALTERNATORS
17
Alte
rnat
orG
uide
Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No. OUTPUT POLARITYVOLT
ADJUSTROTATION
P / N TYPE FEATURES APPLICATION
AVi147J3110HD 24V 120A GROUNDED NO BI-DIR J-180 mount
B+, B-, WL, ExC, AC
17mm shaft
No pulley supplied
Corrosion protected
Volvo207416862077001621429791
AVi147S3108HD 24V 120A GROUNDED NO BI-DIR Swung mount
B+, B-, WL, ExC, AC
17mm shaft
8pk, 55mm pulley
Corrosion protected
Cummins5284097
AVi160J2004 12V 240A INSULATED NO BI-DIR P-type J-180 mount
B+, B-, WL, S, AC
7/8” shaft
No pulley supplied
Corrosion protected
Various MarineCumminsE.P. BarrusA160204RDG20196820124525085, 0124625044AL9960LH, AL9963SB3972732
AVi160J2008 12V 210A INSULATED NO BI-DIR P-type J-180 mount
B+, B-, WL, S, AC
7/8” shaft
No pulley supplied
Corrosion protected
Various MarineCumminsA1602080124525085, 0124625044AL9960LH, AL9963SB3972732
AVi160P2003 12V 240A INSULATED NO BI-DIR P-type Pad mount
B+, B-, WL, S, AC
7/8” shaft
No pulley supplied
Corrosion protected
Various MarineE.P. BarrusA1602030124625043, 01246250460124625048, 0124625051AL9961LH, AL9962SB
BLD2308GH 12V 160A INSULATED NO CW N-type J-180 mount
B+, B-, WL, AC
7/8” shaft
No pulley supplied
Can use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S(TSB-1112)
Various MarineE.P. BarrusRDG2017370
MARINE PRODUCT GUIDE 2014ALTERNATORS
Alte
rnat
orG
uide
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113718 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No. OUTPUT POLARITYVOLT
ADJUSTROTATION
P / N TYPE FEATURES APPLICATION
BLD2333GH 12V 185A INSULATED NO CW N-type J-180 mount
B+, B-, WL, S, AC
7/8” shaft
No pulley suppliedConvert to ext reg with cover A038102788S(TSB-1112)
Various MarineVolvoLNBLD2333GH
BLD3314GH 24V 140A INSULATED YES CW N-type J-180 mount
B+, B-, WL, AC
7/8” shaft
No pulley supplied
Can use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S(TSB-1112)
Various MarineCumminsMTU3975140, 52932135241500150x5271300005
BLD3338GH 24V 140A INSULATED YES CW N-type J-180 mount
B+, B-, WL, AC, Rx
Multipower unit
7/8” shaft, No pulley supplied
Corrosion protectedCan use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S (TSB-1112)
Various MarineMTUx52721300001x52721300005
BLD3365GH 24V 140A INSULATED YES CW N-type J-180 mount
B+, B-, WL, AC
7/8” shaft
No pulley supplied
Corrosion protectedCan use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S (TSB-1112)
Various MarineCumminsBLD3315GH3975140
BLP2310GH 12V 160A INSULATED NO CW N-type Pad mount
B+, B-, WL, AC
7/8” shaft
No pulley supplied
Can use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S(TSB-1112)
Various MarineVolvo8600066, 87000018700002, 87000048700007, 87000188700030
BLP2362GH 12V 200A INSULATED NO CW N-type Pad mount
B+, B-, WL, S, AC
7/8” shaft
No pulley suppliedConvert to ext reg with cover A038102788S(TSB-1112)
Various Marine8600066, 86001278700001, 87000028700004, 87000078700018, 87000308700047
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137
MARINE PRODUCT GUIDE 2014 ALTERNATORS
19
Alte
rnat
orG
uide
Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No. OUTPUT POLARITYVOLT
ADJUSTROTATION
P / N TYPE FEATURES APPLICATION
BLP3312 24V 140A INSULATED YES CW N-type Pad mount
B+, B-, WL, AC
7/8” shaft
No pulley supplied
Can use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S(TSB-1112)
CaterpillarMTUVolvo110-816200619x57521300012BLP3337H-P
BLP3317A 24V 140A INSULATED YES CW N-type Pad mount
B+, B-, WL, AC
7/8” shaft
No pulley supplied
Corrosion protectedCan use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S (TSB-1112)
Various Marine
BLP3300GH 24V 140A INSULATED NO CW N-type Pad mount
B+, B-, D+, AC
7/8” shaft
No pulley supplied
Can use regulator +ve lead as sense leadConvert to ext reg with cover A038102788S(TSB-1112)
MTUx51621300033x5752130002451261017307BLP3300HBLP3300H-1BLP3300H-2
MDA2919 12V 150A INSULATED NO CW N-type J-180 mount
B+, B-, WL, AC
7/8” shaft
No pulley suppliedConvert to ext reg with cover K185103982S(TSB-1116)
Various Marine
MDA2932 12V 150A INSULATED NO CW N-type J-180 mount
B+, B-, WL, AC
7/8” shaft
No pulley suppliedConvert to ext reg with cover K185103982S(TSB-1116)
Various MarineCaterpillarCummins110-4441214134, 0R3527, 39355273935528,39355293604668Rx, 3675222Rx
MDA3929 24V 80A INSULATED NO CW N-type J-180 mount
B+, B-, WL, S, AC
7/8” shaft
No pulley suppliedConvert to ext reg with cover K185103982S(TSB-1116)
CumminsMDA39273967726
MARINE PRODUCT GUIDE 2014ALTERNATORS
Alte
rnat
orG
uide
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113720
PART No. OUTPUT POLARITYVOLT
ADJUSTROTATION
P / N TYPE FEATURES APPLICATION
MDA3946 24V 80A INSULATED NO CW N-type J-180 mount
B+, B-, WL, AC
7/8” shaft
No pulley suppliedConvert to ext reg with cover K185103982S(TSB-1116)
Various MarineCaterpillarCummins1077977, 13221563056492, 3251135, 36751743675201, 3920617, 39206183935530, 4000590, 40034464936879, 6375174 3675174Rx, 3675226Rx3675242Rx, 11039152
MDP2934 12V 150A INSULATED NO CW N-type Pad mount
B+, B-, WL, AC
Can use regulator +ve lead as sense lead
7/8” shaft
No pulley suppliedConvert to ext reg with cover K185103982S(TSB-1116)
Various Marine110-444P10459320, 1045932110459340, 1045934119020387, 1902038819020888, 1902088919020900, 8700008
MDP3939H 24V 55A INSULATED NO CW N-type Pad mount
B+, B-, WL, AC
Can use regulator +ve lead as sense lead
7/8” shaft
No pulley suppliedConvert to ext reg with cover K185103982S(TSB-1116)
MTUx57517200011x57521300010
MDP3941 24V 80A INSULATED NO CW N-type Pad mount
B+, B-, WL, AC
Can use regulator +ve lead as sense lead
7/8” shaft
No pulley suppliedConvert to ext reg with cover K185103982S(TSB-1116)
MTUMANx51621300032x5752130002351261017308
Sta
rte
r m
oto
rS
Sta
rte
rS
Dém
ar
reu
rS
mo
tor
eS D
e a
rr
an
qu
em
oto
rin
i D’a
vvia
men
to
mo
tor
eS D
e pa
rti
Da
ro
zru
Szn
iki
elec
tro
mo
toa
re
ElEk
tropo
krEt
ači
Ста
ртер
ы
MARINE PRODUCT GUIDE 2014STARTER MOTORS
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113722
Sta
rter
Mot
orG
uide
Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)
PAR(ENG) FEATURES APPLICATION
860516GB 24V 5.4kW CW GROUNDED 11t 40.8(M3)48
(69)SAE3 mounting
B+, B-, IGN
Corrosion protected
AIFOIveco0001410106, 00014150170001416011, 000141601209860134204784745, 478474761583669
860518GB 24V 5.4kW CW INSULATED 11t 40.8(M3)48
(69)SAE1 mounting
B+, B-, IGN
Corrosion protected
Volvo Penta, KHD0001410050, 00014106020001415021, 00014160531164269240347, 847330, 8708704776105, 110311263
860541GB 24V 6.6kW CW INSULATED 11t 40.8(M3)48
(69)SAE1 mounting
B+, B-, IGN
Corrosion protected
Volvo Penta0001411010, 000141702300014170355010217950847308, 870998, 8816823803080, 38035984777147, 8473084
860543GB 24V 5.4kW CW INSULATED 9t 34.8(M3)48
(69)SAE1 mounting
B+, B-, IGN
Corrosion protected
Volvo Penta0001402072, 00014020790001414011, 0001416028240503, 241011, 842774843510, 847307, 8707298473076
860545GB 24V 5.4kW CW GROUNDED 11t 40(M3)21
(42.7)SAE3 mounting
B+, B-, IGN
Corrosion protected
AIFO, DeutzIveco0001417005, 00014170060001417059, 00014170730001417074, 09860134300986013440, 09860188104684280, 47322414179626, 4732242, 47828024782803, 500325102500325103
1391010A 24V 15kW CW INSULATED 11t 56.6(6/8 DP)47.6
(71.6)SAE3 mounting
B+, B-, IGN, R, A
Corrosion protected
MTUx524172000071391002, 13910061391008, 1391009S152-24-2, S152-25-6S152-24-7, 152-24-8S152-24-9A, S152-24-10
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137
MARINE PRODUCT GUIDE 2014 STARTER MOTORS
23 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
Sta
rter
Mot
orG
uide
PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)
PAR(ENG) FEATURES APPLICATION
1327A021 12V 3.6kW CW INSULATED 10t 39.5(8/10 DP)47.6 (67)
SAE1 mounting
B+, B-, IGN
CAVPerkinsSabre47920090LRT00618, LRT00641LRS019772873155(R), 2873A0272873155CA45D/F/G/H12-3MS115A12-3M
1327A031 12V 3.6kW CW INSULATED 10t 39.5(8/10 DP)20.6 (40)
Special mounting
B+, B-, IGN
Corrosion protected
CAVSabre26302, 40021LRT606, LRT645CA45D/F/G12-55MS115A12-4M
1327A081 12V 3.6kW CW INSULATED 11t 34.7(10/12 DP)47.6 (67)
SAE1 (offset) mounting
B+, B-, IGN
Corrosion protected
CAVCummins3910563LRS01536CA45G/H12-125MS115A12-11M1320G934, 1320H934
1327A121 12V 3.6kW CW INSULATED 13t 45.8(8/10 DP)47.6 (67)
SAE1 mounting
B+, B-, IGN
Corrosion protected
CAVLister PetterPerkins35136920LRT619, LRT6562873160CA45F/G/H12-11MCA45F/G12-95MS115A12-15M
1327A141 12V 3.6kW CW INSULATED 9t 35.7(M3)26.5 (26)
Special mounting
B+, B-, IGN
Corrosion protected
CAVIveco802208CA45G12-121MS115A12-30M1321G938
1327A431 24V 7.8kW CW INSULATED 10t 39.5(8/10 DP)47.6 (67)
SAE1 mounting
B+, B-, IGN
Corrosion protected
CAV, Lister PetterPerkins, Sabre366044872873303, 28733262873335, 2873303R2873K062CA45D/F/G/H24-3MS115A24-3M1321F/G0321321F/G/H033
MARINE PRODUCT GUIDE 2014STARTER MOTORS
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113724
Sta
rter
Mot
orG
uide
Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)
PAR(ENG) FEATURES APPLICATION
1327A441 24V 7.8kW CW INSULATED 10t 39.5(8/10 DP)20.6 (40)
Special mounting
B+, B-, IGN
Corrosion protected
CAVSabre19820, 40020LRT615, LRT653CA45D/F/G24-55MCA45G24-124MS115A24-4M1321F/G5511321G934
1327A501 24V 7.8kW CW INSULATED 11t 34.7(10/12 DP)47.6 (67)
SAE1 (offset) mounting
B+, B-, IGN
Corrosion protected
CAVCummins3910564CA45F/G/H24-125MS115A24-11M1321F/G/H936
1327A541 24V 7.8kW CW INSULATED 13t 45.8(8/10 DP)47.6 (67)
SAE1 mounting
B+, B-, IGN
Corrosion protected
CAVLister PetterPerkins35136940, 3513696035136970, 28733322873336CA45D/F/G/H24-11MCA45G24-95MS115A24-15M1321F/G/H112
1327A551 24V 7.8kW CW INSULATED 10t 39.5(8/10 DP)20.6 (40)
SAE1 mounting
B+, B-, IGN
Corrosion protected
CAVDorman DieselLister Petter701120, 29745736607703CA45GH24-104MS115A24-16M1321G/H906
1327A691 24V 7.8kW CW INSULATED 9t 35.7(M3)26.5 (26)
Special mounting
B+, B-, IGN
Corrosion protected
CAVAIFOLRT631, LRT640CA45F/G24-121MS115A24-30M1321F/G9291321G938
20500120 12V 2.1kW CW GROUNDED 10t 40(8/10 DP)25.7
(14.4)SAE1 mounting
B+, B-, IGN
DAF26310, 2742447920122LRS120
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137
MARINE PRODUCT GUIDE 2014 STARTER MOTORS
25 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
Sta
rter
Mot
orG
uide
PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)
PAR(ENG) FEATURES APPLICATION
20500124 12V 2.1kW CW GROUNDED 10t 40(8/10 DP)29
(45)SAE1 mounting
B+, B-, IGN
API MarinePerkins2873121, 2873141 2873121T, 2873A0102873A010R, 2873A1022873D00327417, 27435, 27486NSB503, LRS124, LRS153LUC101
20500157 12V 2.1kW CW GROUNDED 11t 39.5(M3)23
(41)SAE1 modified mountingB+, B-, IGN
Perkins0001362060, 9004475303NSB415, NSB507NSB513LRS00131, LRS001572873168
20500190 12V 2.1kW CW GROUNDED 10t 39.5(8/10 DP)25
(43)SAE1 modified mountingB+, B-, IGN
Perkins0001362008, 00013620490986050570NSB509, LRS001902873143, 2873A012(T)2873A017(R), 2873A1042873D005, 2873D007
20500555 12V 2.1kW CCW GROUNDED 11t 39.5(M3)23
(41)SAE1 modified mountingB+, B-, IGN
Lister Petter2041327326270, 27410LRS00555
20500839 24V 3.0kW CW GROUNDED 9t 34.8(M3)27.5
(40.5)SAE1 modified mountingB+, IGN
Iveco0986011160, 09860111614744811, 474484192900352, 92900518504038038, 504072485
20500850 12V 2.4kW CW GROUNDED 9t 34.8(M3)27.5
(40.5)SAE1 modified mountingB+, IGN
FiatIveco0001359091, 00013620320001362039, 000136210509860126704728682, 4807373500333269LRS00850
MARINE PRODUCT GUIDE 2014STARTER MOTORS
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113726
Sta
rter
Mot
orG
uide
Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)
PAR(ENG) FEATURES APPLICATION
20500923GB 24V 2.9kW CW GROUNDED 9t 34.8(M3)28
(46)SAE1 mounting
B+, IGN
Deutz, IvecoKHD, Volvo0001360012, 00013600140001360030, 00013600350001368001, 000136800709860112701161422, 1164995, 11720991173241, 1173820, 130202342488477, 425226536209190
20500968 12V 2.8kW CW GROUNDED 10t 40(8/10 DP)29
(46)SAE1 mounting
B+, B-, IGN
Perkins 0001367069, 098601815109860503512873001(R), 2873A0012873A030, 2873B056(R)2873B071NSB522, NSB524, NSB526LRS00161, LRS00195LRS00691, LRS00968
20500969 12V 2.8kW CW GROUNDED 10t 40(8/10 DP)29
(46)SAE1 mounting
B+, B-, IGN
Perkins2873006R/T, 2873A0142873A029, 2873A0312873B053, 2873B0552873B057(R), 2873B0612873B072, 2873B0732873D002,NSB529, NSB531NSB540, LRS00232LRS00300, LRS02048
20513033 12V 2.0kW CW GROUNDED 9t 34(M3)26
(39)Special mounting
B+, IGN
Mercruiser1946063011, 19460630121946063013, 22800006912280004570, 22800045712280004572, 22800047502280004752
20513040 12V 1.4kW CW GROUNDED 9t 34(M3)26
(39)Special mounting
B+, IGN
API Marine0986024270LRS0112917050
20513065 12V 2.0kW CW GROUNDED 15t 44 21(36) Special mountingB+, IGN
Yanmar12125477010, 1212547701112125477012, 1212567701012497677010, 1249767701112913077010, 1294007701012940077011, 1294007701217100877010, S114257S114349/A, S114483, S13124, S13294S1341/A/B/C/D, S1394
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137
MARINE PRODUCT GUIDE 2014 STARTER MOTORS
27 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
Sta
rter
Mot
orG
uide
PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)
PAR(ENG) FEATURES APPLICATION
20550101 12V 2.2kW CW INSULATED 10t 39.3(8/10 DP)29
(41)SAE1 mounting
B+, B-, IGN
Corrosion protected
API MarineLucas MarinePerkins, Volvo47200628, 4792003447920141, NSB418LRS01339, LRS015032873B058, 2873B059859722LUC102, LUC103
20550103 24V 4.0kW CW INSULATED 10t 32(10/12 DP)47
(69)SAE1 (offset) mounting
B+, B-, IGN
CumminsDAF00013680673283721AELD190(R)
M93R3004SE 24V 5.5kW CW INSULATED 10t* 38.1(M3) 28 (44)SAE1 (offset) mounting
B+, IGN
*Replacing Bosch 9t starter
Deutz, KHDIveco, MANMercedes-Benz0001231028, 00013641000001364301, 00013680010986012700, 09860210001163626, 117958601180999, 0118223542522942
M97R3014SE 24V 5.5kW CW INSULATED 10t 39.6(8/10 DP)47.5 (64)
SAE1 mounting
B+, B-, IGN
CumminsC4934622
M100R2014SE 12V 4.0kW CW GROUNDED 10t* 38.1(M3)28
(44)SAE1 (offset) mounting
B+, IGN
*Replaces Bosch 9t starter
Cummins, Deutz,KHD, Volvo 5263797, 8500044101182233, 0118292501183120, 0118323501183677, 011837121163669, 11646681164994, 11732401174166, 1178026
M100R2015SE 12V 4.0kW CW GROUNDED 10t 39.7(8/10 DP)29
(45)SAE1 mounting
B+, B- (earthed), IGN
Perkins2873K604, 2873K60500013670406005003154, 60050212726005700081, 77000118507701031686
MARINE PRODUCT GUIDE 2014STARTER MOTORS
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113728
Sta
rter
Mot
orG
uide
Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)
PAR(ENG) FEATURES APPLICATION
M100R2016SE 12V 4.0kW CW GROUNDED 10t 39.7(8/10 DP)29
(45)SAE1 mounting
B+, B- (earthed), IGN
Perkins2873K6012873K6070001367069, 09860181510986050351
M105R2511SE 12V 5.0kW CW INSULATED 10t 39.9(8/10 DP)47.5
(66.5)SAE1 mounting
B+, B-, IGN
Rotatable mounting & relay
Caterpillar7N09231993754, 1993762, 19937691993799, 1993881, 19938861993947, 1993963, 82000768300021, 1046100310461081, 1046122510461282, 1046176810478953, 1047895710479036, 10479226
M105R2512SE 12V 5.0kW CW INSULATED 12t 46.6(8/10 DP)47.5
(66.5)SAE1 mounting
B+, B-, IGN
Rotatable mounting & relay
Caterpillar1993885, 1046143110461434, 1046145610461496, 1047901410479071, 1047909810479206, 1047920710479215, 10479242
M105R3037SE 24V 7.5kW CW INSULATED 14t 50.0(M3)48.5
(67.5)Special mounting
B+, B-, IGN
MTU
M105R3050SE 24V 7.5kW CW INSULATED 12t 44.1(M3)48.5
(67.5)Special mounting
B+, B-, IGN
MTUx51117200001M105R3013SE
M105R3086SE 24V 7.5kW CW INSULATED 12t 46.6(8/10 DP)47.5
(66.5)SAE3 mounting
B+, B-, IGN
MTUx57517200010M105R3065SE
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137
MARINE PRODUCT GUIDE 2014 STARTER MOTORS
29 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
Sta
rter
Mot
orG
uide
PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)
PAR(ENG) FEATURES APPLICATION
M105R3087SE 24V 7.5kW CW INSULATED 12t 46.6(8/10 DP)47.5
(66.5)SAE1 mounting
B+, B-, IGN
MTUx57517200011M105R3066SE
M105R3095SE 24V 7.5kW CW INSULATED 12t 46.6(8/10 DP)47.5
(66.5)SAE1 mounting
B+, B-, IGN
MTUx54417200004M105R3051SE
M105R3502SE 24V 7.5kW CW INSULATED 11t 57.6(6/8 DP)47.5
(66.5)SAE3 mounting
B+, B-, IGN
Rotatable mounting & relay
Cummins, Caterpillar10R0400, 4N1062, 6V55397T0794, 7T0800, 7T08017T08061443674, 30210363103305, 31039163103952, 52840851443674R, 3021036Rx3603862RxCH12405
M105R3504SE 24V 7.5kW CW GROUNDED 12t 46.7(8/10 DP)47.5
(66.5)SAE1 mounting
B+, B- (earthed), IGN
Rotatable mounting & relay
Caterpillar, Perkins2873K116, 10470401068557,10685582071511, 20715162071517, 20715190R4263, 10R03956V5720, OR4263
M105R3505SE 24V 7.5kW CW INSULATED 12t 46.7(8/10 DP)47.5
(66.5)SAE3 mounting
B+, B-, IGN
Rotatable mounting & relay
Caterpillar, Cummins, Perkins1068552, 20715522071553, 207156010R0399, 3P00075A6494, 3011895, 31027633281634, 3675297, 3902661 3907821, 3910646, 39308453938499, 3938503, 39774264891301, 3604233Rx3604484Rx, 3675120Rx
M105R3508SE 24V 7.5kW CW INSULATED 11t 57.6(6/8 DP)47.5
(66.5)SAE3 mounting
B+, B-, IGN
Rotatable mounting & relay
Caterpillar, Cummins, FiatIveco, Renault3T2646, 3T2650, 6N18862T0797310391447809745000811448
MARINE PRODUCT GUIDE 2014STARTER MOTORS
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113730
Sta
rter
Mot
orG
uide
Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)
PAR(ENG) FEATURES APPLICATION
M105R3509SE 24V 7.5kW CW INSULATED 12t 46.7(8/10 DP)47.5
(66.5)SAE3 mounting
B+, B-, IGN
Rotatable mounting & relay
Cummins3102767, 39774285254108, 52564155284108M009T82671M009T82672
M105R3510SE 24V 7.5kW CW GROUNDED 10t 40(8/10 DP)47.5
(66.5)SAE1 (offset) mounting
B+, B- (Earthed), IGN
Rotatable mounting & relay
Cummins3675116, 3965282384011001503675116Rx
M105R3513SE 24V 7.5kW CW INSULATED 12t 46.7(8/10 DP)47.5
(66.5)SAE3 mounting
B+, B-, IGN
Rotatable mounting & relay
Volvo Penta3801289, 38038383586798M009T82179M009T84079
M105R3514SE 24V 7.5kW CW INSULATED 12t 44.1(M3)47.5
(66.5)SAE3 mounting
B+, B-, IGN
Rotatable mounting & relay
Mercedes-BenzInsulated version of 0001330011, 00013300200001372005, 00013720060986018370, 09860208800986022980M009T80471, M009T80472M009T80473, M009T83671M009T84771
M110R2601SE 12V 7.0kW CW INSULATED 12t 44.1(M3)47.5
(66.5)SAE3 mounting
B+, B-, IGN
Rotatable mounting & relay
Corrosion protected
Mercedes-BenzM009T70379M009T7117919011505, 190115148200084, 82004348300013
M110R2602SE 12V 7.0kW CW INSULATED 12t 46.7(8/10 DP)47.5
(66.5)SAE3 mounting
B+, B-, IGN
Rotatable mounting & relay
Corrosion protected
Volvo21019456, 21019460M9T71179MK2078MK2079VV2079
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137
MARINE PRODUCT GUIDE 2014 STARTER MOTORS
31 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
Sta
rter
Mot
orG
uide
PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)
PAR(ENG) FEATURES APPLICATION
M110R2603SE 12V 7.0kW CW INSULATED 11t 57.6(6/8 DP)47.5
(66.5)SAE3 mounting
B+, B-, IGN
Overcrank protection
Rotatable mounting & relay
Corrosion protected
Caterpillar, Cummins3604665(Rx)10461028, 1046105510461062, 1046107510461096, 1046116510461183, 1046118510461232, 1047903010479038, 1047906210479082
M110R2615SE 12V 7.0kW CW INSULATED 11t 57.6(6/8 DP)47.5
(66.5)SAE3 mounting
B+, B-, IGN
Rotatable mounting & relay
Corrosion protected
Caterpillar, Cummins3815734C91M983579, MIB970777(FL)MIB970975(FL)8200050, 8200090, 82000918200104, 8200289, 82002908200308, 8300009, 830001919011518, 1901152119011529, 19011530
M125R2001SEP 12V 8.0kW CW INSULATED 11t 57.6(6/8 DP)47.5
(66.5)SAE3 mounting
B+, B-, IGN
Rotatable mounting
Corrosion protected
Caterpillar, Cummins3021034, 30210353610942, 3603863Rx3604322Rx3T3154, 4L9547, 4N09564N1064, 4N956, 5L41605L4168, 5L4169, 5L56675L5867, 8C3592, 8C35938C3652, 8L8206, 9L62009N0716, 9N0721
M125R2600SE 12V 8.0kW CW INSULATED 14t 50.5(M3)48.5
(69.5)SAE3 (offset) mounting
B+, B-, IGN
Rotatable mounting & relay
Corrosion protected
Detriot DieselMIB970379, MIB9711798200082, 82000848200287, 82002988200329, 83000088300013, 830005819011514, 19011525
M125R2632SE 12V 8.0kW CW INSULATED 11t 57.6(6/8 DP)48.5
(69.5)SAE3 mounting
B+, B-, IGN
Rotatable mounting & relay
Corrosion protected
CumminsMIB70579(FL)MIB970777(FL)MIB970975(FL)8200050, 82000908200091, 82001048200289, 82002908200308, 830001919011518, 1901152119011529, 19011530
M125R2634SE 12V 8.0kW CW INSULATED 12t 46.3(8/10 DP)48.5
(69.5)SAE3 mounting
B+, B-, IGN
Rotatable mounting & relay
Corrosion protected
Volvo8200182, 82002148200417, 8200572830006021019456, 21019460MK2078, MK2079VV2079, VV2080
MARINE PRODUCT GUIDE 2014STARTER MOTORS
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113732
Sta
rter
Mot
orG
uide
Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)
PAR(ENG) FEATURES APPLICATION
M125R3001SE 24V 9.0kW CW INSULATED 11t 57.6(6/8 DP)48.5
(69.5)SAE3 mounting
B+, B-, IGN
Rotatable mounting & relay
Corrosion protected
Caterpillar, Cummins4M5615, 4N0959, 4N33434N3349, 5L3648, 5L44055L5353, 5L648, 5L82055LG48, 5N2685, 6N96676N9677, 6T0647, 6V05116V0590, 8L8205, 9L64649L6474, 9L64843603868Rx, 3603888Rx3632273Rx, 3632274Rx
MS1-401A 24V 8.3kW CW INSULATED 11t 57.1(6/8 DP)47.8(69)
SAE3 mounting
B+, B-, IGN
Rotatable mounting
Corrosion protected
GR version M105R3502SE
ButecCaterpillarCummins10R0400, 4N10626V5539, 7T0794, 7T08007T0801, 7T0806135160, 135161, 135162135163, 173006, 173007555241, 706620, 3021036
MS1-410A 24V 8.3kW CW INSULATED 12t 46.3(8/10 DP)47.8(69)
SAE3 mounting
B+, B-, IGN
Rotatable mounting
Corrosion protected
ButecCaterpillarCummins1068552, 10R03993P0007, 5A6494, 1971273011895, 32816343902661, 39078213910646, 39384993938502, 3604233Rx3604484Rx, 3675120Rx
MS1-419A 24V 8.3kW CW INSULATED 12t 46.3(8/10 DP)47.8(69)
SAE3 mounting
B+, B-, IGN
Rotatable mounting
Corrosion protected
Butec, CaterpillarCummins, Fiat, Iveco6V5207, 6V5226, 6V52276V5537, 7S3622, 7T07987T0799, 7T1082, 7T17998C3597, 8C3647, 8C36508C3651, 8N2145, 9G43389G4339, 9M1662, 9x44543604784Rx, 731301924816170
MS1-464 24V 8.3kW CW INSULATED 12t 46.3(8/10 DP)47.8(69)
SAE3 mounting
B+, B-, IGN
Rotatable mounting
Corrosion protected
ButecCumminsPerkinsMS6-301A5257544CV5296, CV65430 OD20399854006(Z)
MS1-500 24V 8.3kW CW INSULATED 12t 46.3(8/10 DP)47.8(69)
SAE1 mounting
B+, B-, IGN
Rotatable mounting
Corrosion protected
GR version M105R3504SE
CaterpillarVolvo20715518723649000872364
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137
MARINE PRODUCT GUIDE 2014 STARTER MOTORS
33 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
Sta
rter
Mot
orG
uide
PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)
PAR(ENG) FEATURES APPLICATION
MS3-502 24V 7.5kW CW INSULATED 12t 46.3(8/10 DP)48.5(66)
SAE3 mounting
B+, B-, IGN
Rotatable mounting
Corrosion protected
ButecCumminsPerkins3975134OD166001MS3-41850461, 854082, 850615(Z)855783(Z)ZMS3-502
MS4-400 24V 5.5kW CW INSULATED 12t* 37.3(10/12 DP)48.5
(64.7)SAE1 (offset) mounting
B+, B-, IGN
Rotatable mounting
Corrosion protected
*Replacing 10t LNS starter
Cummins3399104859532, 860606LNS452411
MS4-401 24V 5.5kW CW INSULATED 12t* 37.3(10/12 DP)48.5
(64.7)SAE1 (offset) mounting
B+, B-, IGN
Rotatable mounting
Corrosion protected
*Replacing 10t LNS starter
CumminsIveco3283586, 49306063281354Rx, 859500PB92901937, 929019443352622R91856766, 859411, 859422, 859500, 859970LNS452421, LNS452424LNS452426
MS4-405 24V 5.5kW CW INSULATED 10t 39.7(8/10 DP)48.5
(64.7)SAE1 mounting
B+, B-, IGN
Rotatable mounting
Corrosion protected
Cummins860362LNS4524
MS4-406 24V 5.5kW CW INSULATED 10t 39.7(8/10 DP)29.6
(45.8)SAE1 mounting
B+, B-, IGN
Rotatable mounting
Corrosion protected
Butec859024, 859432LNS45244, LNS45247
MS4-407 24V 5.5kW CW INSULATED 10t 39.7(8/10 DP)48.5
(64.7)SAE1 mounting
B+, B-, IGN
Rotatable mounting
Corrosion protected
ButecCummins860360(Z)LNS452431
MARINE PRODUCT GUIDE 2014STARTER MOTORS
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113734
Sta
rter
Mot
orG
uide
Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)
PAR(ENG) FEATURES APPLICATION
MS4-500A 24V 5.5kW CW INSULATED 12t* 37.3(10/12 DP)48.5
(64.7)SAE1 (offset) mounting
B+, B-, IGN
Rotatable mounting
Corrosion protected
*Replacing 10t LNS starter
Cummins3975153, 40788004930606MZH9195MS4-403859920, 857673ZLNS452425
MS7-501A 24V 9.0kW CW INSULATED 11t 57.1(6/8 DP)45.8
(69.7)SAE3 mounting
B+, B-, IGN
Rotatable mounting
Corrosion protected
CumminsMTUMercedes-Benz4308730A0041519901A0051511001x00001906
MS7-502A 24V 9.0kW CW INSULATED 11t 57.1(6/8 DP)45.8
(69.7)SAE3 mounting
B+, B-, IGN
Rotatable mounting
Corrosion protected
MTUMercedes-Benz0001420028A0051510001A0051510201x00001910
MS7-505 24V 9.0kW CW INSULATED 11t 57.1(6/8 DP)45.8
(69.7)SAE3 mounting
B+, B-, IGN
Rotatable mounting
Corrosion protected
MTUx52417200003
MS7-506 24V 9.0kW CW INSULATED 11t 57.1(6/8 DP)45.8
(69.7)SAE3 mounting
B+, B-, IGN
Rotatable mounting
Corrosion protected
MTUx52417200004
MS7-509 24V 9.0kW CW INSULATED 11t 57.1(6/8 DP)45.8
(69.7)SAE3 mounting
B+, B-, IGN
Rotatable mounting
Corrosion protected
MTUx52417200010
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137
MARINE PRODUCT GUIDE 2014 STARTER MOTORS
35 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
Sta
rter
Mot
orG
uide
PART No OUTPUT ROTN POLARITY TEETHPINION OD (MODULE)
PAR(ENG) FEATURES APPLICATION
MS7-510 24V 9.0kW CW INSULATED 11t 57.1(6/8 DP)45.8
(69.7)SAE3 mounting
B+, B-, IGN
Rotatable mounting
Corrosion protected
MTUx52417200011
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137
Au
xili
Ar
y eq
uip
men
tZu
sAtZ
ger
äte
equ
ipem
ents
Au
xili
Air
eseq
uip
o A
uxi
liA
rA
ttr
eZZA
tur
A A
usi
liA
riA
equ
ipA
men
to A
uxi
liA
rW
ypo
saże
nie
po
mo
cn
icze
ech
ipa
men
te a
uxi
lia
re
pom
oć
na o
prem
aД
оп
ол
ни
тел
ьн
ое
об
ору
До
ва
ни
е
MARINE PRODUCT GUIDE 2014AUXILIARY EQUIPMENT
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113738
Aux
iliar
y E
quip
men
t Gui
de
Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
REGULATORS
PART No. TYPE VOLTAGE VOLTAGE ADJUSTMENT APPLICATION CROSS-REFERENCE
1861650 572-1 28.0V 27.0V / 28.0V / 29.0V Standard regulatorRemote fitmentAC5
440D-24-2, 1697D520548-1, 1861600
1861652 572-2 28.0V 27.0V / 28.0V / 29.0V Current / voltage regulation60A (max)
Remote fitmentAC203
548-2, 1861602
1861654 572-3 28.0V 26.5V / 28.0V / 29.0V Current / voltage regulation80A (max)
Remote fitmentAC203
548-3, 1861604
1861656 572-4 27.5V 26.5V / 27.5V / 28.5V For use with split chargingRemote fitmentAC5
440D-24-14, 1697D548
1861660 572-6 13.75V 13.25V / 13.75V / 14.25V Standard regulatorRemote fitmentAC5
440D-12-2, 1697D220
1861662 572-7M 13.75V 13.25V / 13.75V / 14.25V Standard regulator, with waterproof cover (not shown)
Remote fitmentAC5
440D-12-3M, 1697D230
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 1137
MARINE PRODUCT GUIDE 2014 AUXILIARY EQUIPMENT
39 Sales Tel: +44 (0) 20 8231 1137 Sales Tel: +44 (0) 20 8575 9575 www.prestolite.com
Aux
iliar
y E
quip
men
t Gui
de
PART No. TYPE VOLTAGE VOLTAGE ADJUSTMENT APPLICATION CROSS-REFERENCE
1861666 572-9 14.25V 13.75V / 14.25V / 14.75V Standard regulator set at 14.25v (for maintenance free batteries)
AC5
440D-12-13, 1697D546
8RG2135S 8RG 14.2V V Sense WL and Sense terminals, for split charging
Integrated fitment
8LHA / 8LHPBLD / BLP (brushless)LBA / LBP
8RG3078S 8RG 28.0V 27.0V - 29.0V Integrated fitment 8LHA3095R, 8LHA3096U8LHA / 8LHPBLD / BLP (brushless)
8RL3109S 8RL 28.0V 26.8V - 29.5V Integrated fitmentReplaces 8RL3024S
Flex-lead rectifier type 8SC’s (old style)
Note: L-shaped circuit board interface
8RL3024S, 8RL3021, 8RL3021-C, 8RL3022105-396, 105-251
8RL3136S 8RL 28.0V 26.8V - 29.5V Integrated fitmentReplaces 8RL3028S
Fixed-lead frame type 8SC’s (new style)
Note: Plug connection
8RL3028S
MARINE PRODUCT GUIDE 2014AUXILIARY EQUIPMENT
www.prestolite.com Sales Fax: +44 (0) 20 8575 9575 Sales Tel: +44 (0) 20 8231 113740
Aux
iliar
y E