Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
Input Voltage
Input Current
Input Power
Power Factor
Luminance
Luminous Efficiency
CRI
Beam Angle
Main Structure
Output Voltage
Output Current
Driver Efficiency
LED Manufacturer
LED Type
LED Quantity
LED Efficacy
Color Temperature
Photocell -
Lifespan
Warranty
IP Rating
Operating Temperature
Storage Temperature.Humidity
Safety Standards
Withstand Voltage
Grounding Resistance
Electromagnetic Compatibility
Dimension Pls refer to attached dimensional drawing
Qty / Carton
Cat# 7155115 Watt
1/2" Adjustable Knuckle Mount
14.39 W
PF≥ 0.93
1663 LM
115.57 LM/W
Model: 71551
100-277VAC 50/60HZ
0.127A Max
0.25A
88%
Phillips
LUMILED LUXEON 3030 LED
120x90°
Aluminium Housing + Polycarbonate Lens
36-60VDC
50,000+ Hrs.
5 Years
IP65 Wet Locations
-40F - +131F
18 PCS
130 LM/W
5000K
Not Included
-40℃—+80℃ , 10—90% RH
UL1598,UL8750, EN60598, EN61347-2-13, EN62031, EN62471
I/P-FG: 2121VDC
≤0.5Ω,OK
18PCS
OVERALL LAMP
PARAMETERS
LED DRIVER
LED
LIFESPAN &
ENVIRONMENT
SAFETY&EMC
OTHERS
EN55015, EN61000-2-3, EN61000-3-3, EN61547
RoHS
82.5
QPL ID # PVBDJBSK
Dimensions:
www.morrisproducts.com
http://www.morrisproducts.com/
Quality Assured NVLAP LAB CODE 0096o-D
LM-79-08 Test Report
For
Morris Products Inc.
53 Carey Rd Queensbury, NY 12804
Brand Name: Morris
LED FLOOD LIGHT
Model: 71551
Laboratory: Leading Testing Laboratories
NVLAP CODE: 200960-0 Tel : +86-571-5668.0806
www.ledtestlab.com
Report No.: HZ15ll004la
The laboratory that conducted the testing detailed in this report has been accredited for SSL by NVLAP. Test specifications: Date of Receipt Date of Test Test item
Reference Standard
Reviewed by:
: Nov. 27, 2015 : Dec. 01, 2015 : Total Luminous Flux, Luminous Distribution Intensity, Luminous Efficacy, Correlated Color Temperature, Color Rendering Index, Chromaticity Coordinate, Electrical parameters : IESNA LM-79-2008 Approved Method for the Electrical and Photometric
Engineer: April Zou Dec. 04, 2015
Jim Zhang Dec. 04, 2015
Note: This report does not imply product certification, approval or endorsement by NVLAP. NlST, or any agency of the Federal Government.
Report No.: HZ15110041a
Prepared by: Leading Testing Laboratories No.1805, DongLiu road, BinJiang District, Hangzhou, China
Page 2 of 12
Tel: +86-571-56680806 www.ledtestlab.com
Test Summary Sample Tested: 71551
Luminous Efficacy (Lumens /Watt)
Total Luminous Flux (Lumens)
Power (Watts)
Power Factor
96.6
1413.5 14.63 0.9810
CCT (K)
CRI
Stabilization Time (Light & Power)
5243
83.7 60
IES Classification
Longitudinal Classification NEMA Type for Flood Fixture
Type I
Very Short 7 H x 7 V
Table 1: Executive Data Summary
Sample Photo
0 Horizontal
Figure 1- Overview of the sample
Equipment Under Test (EUT) Name : LED FLOOD LIGHT Model : 71551 Electrical Ratings : 120~277Vac, 50/60Hz, 15W Product Description : 5000K, 1 LED bar, Architectural Flood and Spot Luminaires Manufacturer : Morris Products Inc.
Address : 53 Carey Rd Queensbury, NY 12804
Report No.: HZ15110041a
Prepared by: Leading Testing Laboratories No.1805, DongLiu road, BinJiang District, Hangzhou, China
Page 3 of 12
Tel: +86-571-56680806 www.ledtestlab.com
TABLE OF CONTENT
LM-79-08 Test Report............................................................................................................................................ 1
Sample Photo.......................................................................................................................................................... 2
TEST RESULTS .................................................................................................................................................... 4
Spectral Power Distribution ................................................................................................................................... 5
IESNA Luminaire Flux Distribution Table ............................................................................................................ 6
Isoilluminance Plots of Horizontal Illuminance ..................................................................................................... 7
Luminous Intensity Distribution Plots.................................................................................................................... 8
Luminous Intensity Data ........................................................................................................................................ 9
EQUIPMENT LIST ............................................................................................................................................. 11
TEST METHODS ................................................................................................................................................ 11
Seasoning of SSL Product................................................................................................................................ 11
Goniophotometer Method ................................................................................................................................ 11
Photometric and Electrical Measurements ................................................................................................... 11
Color Characteristics Measurements............................................................................................................ 12
Color Spatial Uniformity ............................................................................................................................. 12
Report No.: HZ15110041a
Prepared by: Leading Testing Laboratories No.1805, DongLiu road, BinJiang District, Hangzhou, China
Page 4 of 12
Tel: +86-571-56680806 www.ledtestlab.com
Special Color Rendering Indices R1 82R2 89R3 93R4 83R5 83R6 85R7 87R8 68R9 10R10 74R11 82R12 63R13 84R14 97
TEST RESULTS
Test ambient temperature was 24.5 . Sample orientation was light down. Test was conducted without a dimmer in the circuit. The stabilization time of the sample was 60 minutes, and the total operating time including stabilization was 85 minutes.
Goniophotometer Method The photometric distance is 30m. Luminous data was taken at 0.5°vertical intervals and 5 °horizontal intervals.
Parameter
Result
Test Voltage (V) 120.0 277.0Voltage frequency (Hz) 60 60Test Current (A) 0.124 0.060Power Factor 0.9810 0.8989Test Power (W) 14.63 14.94THD A% 17.41 17.06Luminous Efficacy (lm/W) 96.6 Total Luminous Flux (lm) 1413.5Color Rendering Index (CRI) 83.7R9 10Correlated Color Temperature (CCT) (K) 5243Chromaticity (Chroma x, Chroma y) (0.3389, 0.3513)Chromaticity (Chroma u, Chroma v) (0.2074, 0.3224)Chromaticity (Chroma u’, Chroma v’) (0.2074, 0.4836)Duv 0.0024Average Beam Angle (°) 104.5Center Beam Candle Power (cd) 548Spacing Criteria 1.27 (0°-180°)/
1.38 (90°-270°)Zonal Lumens in the 0°-60°Zone 88.12%Zonal Lumens in the 60°-90°Zone 11.73%Zonal Lumens in the 90°-120°Zone 0.03%Zonal Lumens in the 120°-180°Zone 0.12%
Table 2: Test data per Goniophotometer Method Note: According to CIE 1976 (u’,v’) diagram, u’ = u = 4x/(-2x+12y+3), v’ = 3v/2 = 9y/(-2x+12y+3).
Report No.: HZ15110041a
Prepared by: Leading Testing Laboratories No.1805, DongLiu road, BinJiang District, Hangzhou, China
Page 5 of 12
Tel: +86-571-56680806 www.ledtestlab.com
Spectral Power Distribution
Chart 1: Spectral Power Distribution
Report No.: HZ15110041a
Prepared by: Leading Testing Laboratories No.1805, DongLiu road, BinJiang District, Hangzhou, China
Page 6 of 12
Tel: +86-571-56680806 www.ledtestlab.com
IESNA Luminaire Flux Distribution Table
Zone Lumens Luminaire % FL - Front-Low (0-30) 226.5 16.0 FM - Front-Medium (30-60) 399.2 28.2 FH - Front-High (60-80) 82.1 5.8 FVH - Front-Very High (80-90) 3.9 0.3 Total Forward Light 711.7 50.3
BL - Back-Low (0-30) 228.4 16.2 BM - Back-Medium (30-60) 391.6 27.7 BH - Back-High (60-80) 76.9 5.4 BVH - Back-Very High (80-90) 3.0 0.2 Total Back Light 699.9 49.5
UL - Uplight-Low (90-100) 0.1 0.0 UH - Uplight-High (100-180) 2.0 0.1 Total Up Light 2.1 0.1
BUG (Back, Up, Glare) Rating B1-U1-G0
Table 3: Flux Distribution Data
Zone
Downward Lumens
Upward Lumens
Total Lumens
House Side 699.9 0 699.9 Street Side 711.7 0 711.7
Table 4: Flux Distribution Table
Note: The Flux in this table might be a little different from the total flux in Table 2 due to rounding.
Report No.: HZ15110041a
Prepared by: Leading Testing Laboratories No.1805, DongLiu road, BinJiang District, Hangzhou, China
Page 7 of 12
Tel: +86-571-56680806 www.ledtestlab.com
Isoilluminance Plots of Horizontal Illuminance
Distance In Units Of Mounting Height Values Based On 10 Foot Mounting Height 1/2 Maximum Candela Trace Shown As Dashed Curve (+) = Maximum Candela Point
Chart 2: Illuminance Plot (Footcandles)
Report No.: HZ15110041a
Prepared by: Leading Testing Laboratories No.1805, DongLiu road, BinJiang District, Hangzhou, China
Page 8 of 12
Tel: +86-571-56680806 www.ledtestlab.com
Luminous Intensity Distribution Plots
Chart 3: Maximum Plane and Cone Plots of Candela Maximum Candela = 577.45 Located At Horizontal Angle = 190, Vertical Angle = 16.5 # 1 - Vertical Plane Through Horizontal Angles (190 - 10) (Through Max. Cd.) # 2 - Horizontal Cone Through Vertical Angle (16.5) (Through Max. Cd.)
Chart 4: Polar Candela Distribution
Report No.: HZ15110041a
Prepared by: Leading Testing Laboratories No.1805, DongLiu road, BinJiang District, Hangzhou, China
Page 9 of 12
Tel: +86-571-56680806 www.ledtestlab.com
Luminous Intensity Data
Table 5: Luminous Intensity Data
Report No.: HZ15110041a
Prepared by: Leading Testing Laboratories No.1805, DongLiu road, BinJiang District, Hangzhou, China
Page 10 of 12
Tel: +86-571-56680806 www.ledtestlab.com
Table 6: Luminous Intensity Data
Report No.: HZ15110041a
Prepared by: Leading Testing Laboratories No.1805, DongLiu road, BinJiang District, Hangzhou, China
Page 11 of 12
Tel: +86-571-56680806 www.ledtestlab.com
EQUIPMENT LIST
Test Equipment
Model Equipment No. Calibration Date
Calibration Due date
Goniophotometer system GO-R5000 HZTE011-01 Jul. 17, 2015 Jul. 16, 2016 Digital Power Meter PF2010A HZTE028-01 Jul. 17, 2015 Jul. 16, 2016 AC Power Supply PCR 500L HZTE001-08 Jul. 17, 2015 Jul. 16, 2016 DC Power Supply WY12010 HZTE004-03 Jul. 17, 2015 Jul. 16, 2016 Temperature Meter TES1310 HZTE017-01 Jul. 17, 2015 Jul. 16, 2016 Standard Source D908 HZTE012-01 Jul. 23, 2015 Jul. 22, 2016 Standard source SCL-1400 HZTE012-02 Oct. 21, 2015 Oct. 20, 2016
Table 7: Test Equipment List TEST METHODS
Seasoning of SSL Product
For the purpose of rating new SSL products, SSL products shall be tested with no seasoning. Therefore, no seasoning was performed.
Goniophotometer Method
Photometric and Electrical Measurements
An EVERFINE Type C Model GO-R5000 Goniophotometer was used to measure the intensity at each angle of distribution for each sample. The photometric distance is 2.475m for near-field measurement or 30m for far-field measurement. Bandwidth of spectroradiometer is 380nm-780nm. Ambient temperature was measured at the same height of the sample mounted on the Goniophotometer equipment. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation. The stabilization time typically ranges from 30 min (small integrated LED lamps) to 2 or more hours for large SSL luminaires). It can be judged that stability is reached when the variation (maximum – minimum) of at least 3 readings of the light output and electrical power over a period of 30 min, taken 15 minutes apart, is less than 0.5 %. Electrical measurements including voltage, current, and power were measured using the Everfine Digital Power Meter. Some graphics were created with Photometric Plus software. The standard reference of the Goniophotometer system is halogen incandescent lamp, the intensity distribution type is omni-directional, and is traceable to the National Institute of Metrology P.R. China. The uncertainty of goniophotometer system reported in this document is expended uncertainty is 1.8% with a coverage factor k=2.
Report No.: HZ15110041a
Prepared by: Leading Testing Laboratories No.1805, DongLiu road, BinJiang District, Hangzhou, China
Page 12 of 12
Tel: +86-571-56680806 www.ledtestlab.com
Color Characteristics Measurements
The color characteristics of SSL products include chromaticity coordinates, correlated color temperature, and color rendering index. These characteristics of SSL products may be spatially non-uniform, and thus, in order that they can be specified accurately, the color quantities shall be measured as values that are spatially average, weighted to intensity, over the angular range where light is intentionally emitted from the SSL product. The color characteristics measurements are using gonio-spectroradiometer.
Color Spatial Uniformity
The characteristics of SSL products may be spatially non-uniform, the chromaticity coordinate shall be measured at two vertical planes (C=0°/180° and C=90°/270°) and at 10° or less intervals for vertical angle until the light output dropped to below 10% of the peak intensity. The average weighted chromaticity coordinate was calculated from these points. The data was then analyzed to check for delta color differences of the u', v' chromaticity coordinates. The spatial non-uniformity of chromaticity, u'v', is determined as the maximum deviation ( distance on the CIE (u', v') diagram) among all measured po in ts from the spatially a v e r a g e d chromaticity coordinate. The geometry for the chromaticity measurement using gonio-spectroradiometer is shown as following.
*** End of Report *** This report is considered invalidated without the Special Seal for Inspection of the LTL. This report shall not be altered, increased
or deleted. The results shown in this test report refer only to the sample(s) tested. Without written approval of LTL, this test report
shall not be copied except in full and published as advertisement.
FLE15W