Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure Output Voltage Output Current Driver Efficiency LED Manufacturer LED Type LED Quantity LED Efficacy Color Temperature Photocell - Lifespan Warranty IP Rating Operating Temperature Storage Temperature.Humidity Safety Standards Withstand Voltage Grounding Resistance Electromagnetic Compatibility Dimension Pls refer to attached dimensional drawing Qty / Carton Cat# 71551 15 Watt 1/2" Adjustable Knuckle Mount 14.39 W PF≥ 0.93 1663 LM 115.57 LM/W Model: 71551 100-277VAC 50/60HZ 0.127A Max 0.25A 88% Phillips LUMILED LUXEON 3030 LED 120x90° Aluminium Housing + Polycarbonate Lens 36-60VDC 50,000+ Hrs. 5 Years IP65 Wet Locations -40F - +131F 18 PCS 130 LM/W 5000K Not Included -40℃—+80℃ , 10—90% RH UL1598,UL8750, EN60598, EN61347-2-13, EN62031, EN62471 I/P-FG: 2121VDC ≤0.5Ω,OK 18PCS OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC OTHERS EN55015, EN61000-2-3, EN61000-3-3, EN61547 RoHS 82.5 QPL ID # PVBDJBSK

Cat# 71551 15 Watt 1/2 Adjustable Knuckle Mount RoHSTest Equipment Model Equipment No. Calibration Date Calibration Due date Goniophotometer system GO-R5000 HZTE011-01 Jul. 17, 2015

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • Input Voltage

    Input Current

    Input Power

    Power Factor

    Luminance

    Luminous Efficiency

    CRI

    Beam Angle

    Main Structure

    Output Voltage

    Output Current

    Driver Efficiency

    LED Manufacturer

    LED Type

    LED Quantity

    LED Efficacy

    Color Temperature

    Photocell -

    Lifespan

    Warranty

    IP Rating

    Operating Temperature

    Storage Temperature.Humidity

    Safety Standards

    Withstand Voltage

    Grounding Resistance

    Electromagnetic Compatibility

    Dimension Pls refer to attached dimensional drawing

    Qty / Carton

    Cat# 7155115 Watt

    1/2" Adjustable Knuckle Mount

    14.39 W

    PF≥ 0.93

    1663 LM

    115.57 LM/W

    Model: 71551

    100-277VAC 50/60HZ

    0.127A Max

    0.25A

    88%

    Phillips

    LUMILED LUXEON 3030 LED

    120x90°

    Aluminium Housing + Polycarbonate Lens

    36-60VDC

    50,000+ Hrs.

    5 Years

    IP65 Wet Locations

    -40F - +131F

    18 PCS

    130 LM/W

    5000K

    Not Included

    -40℃—+80℃ , 10—90% RH

    UL1598,UL8750, EN60598, EN61347-2-13, EN62031, EN62471

    I/P-FG: 2121VDC

    ≤0.5Ω,OK

    18PCS

    OVERALL LAMP

    PARAMETERS

    LED DRIVER

    LED

    LIFESPAN &

    ENVIRONMENT

    SAFETY&EMC

    OTHERS

    EN55015, EN61000-2-3, EN61000-3-3, EN61547

    RoHS

    82.5

    QPL ID # PVBDJBSK

  • Dimensions:

    www.morrisproducts.com

    http://www.morrisproducts.com/

  •  

    Quality Assured NVLAP LAB CODE 0096o-D

       

    LM-79-08 Test Report  

     For

    Morris Products Inc.  

    53 Carey Rd Queensbury, NY 12804

    Brand Name: Morris

      

    LED FLOOD LIGHT

    Model: 71551

     Laboratory: Leading Testing Laboratories

     

    NVLAP CODE: 200960-0 Tel : +86-571-5668.0806

    www.ledtestlab.com  

    Report No.: HZ15ll004la    

    The laboratory that conducted the testing detailed in this report has been accredited for SSL by NVLAP.   Test specifications: Date of Receipt Date of Test Test item

       

    Reference Standard     

    Reviewed by:

      : Nov. 27, 2015 : Dec. 01, 2015 : Total Luminous Flux, Luminous Distribution Intensity, Luminous Efficacy, Correlated Color Temperature, Color Rendering Index, Chromaticity Coordinate, Electrical parameters : IESNA LM-79-2008 Approved Method for the Electrical and Photometric

      

    Engineer: April Zou Dec. 04, 2015

    Jim Zhang Dec. 04, 2015

     Note: This report does not imply product certification, approval or endorsement by NVLAP. NlST, or any agency of the Federal Government.

  • Report No.: HZ15110041a

    Prepared by: Leading Testing Laboratories No.1805, DongLiu road, BinJiang District, Hangzhou, China

    Page 2 of 12

    Tel: +86-571-56680806 www.ledtestlab.com

     

     

     Test Summary Sample Tested: 71551

     

    Luminous Efficacy (Lumens /Watt)

    Total Luminous Flux (Lumens)

    Power (Watts)

    Power Factor

     

    96.6  

    1413.5 14.63 0.9810

    CCT (K)

     CRI

    Stabilization Time (Light & Power)

     

    5243  

    83.7 60  

    IES Classification  

    Longitudinal Classification NEMA Type for Flood Fixture  

    Type I  

    Very Short 7 H x 7 V

    Table 1: Executive Data Summary  

    Sample Photo           

    0 Horizontal         

    Figure 1- Overview of the sample   

    Equipment Under Test (EUT) Name : LED FLOOD LIGHT Model : 71551 Electrical Ratings : 120~277Vac, 50/60Hz, 15W Product Description : 5000K, 1 LED bar, Architectural Flood and Spot Luminaires Manufacturer : Morris Products Inc.

    Address : 53 Carey Rd Queensbury, NY 12804

  • Report No.: HZ15110041a

    Prepared by: Leading Testing Laboratories No.1805, DongLiu road, BinJiang District, Hangzhou, China

    Page 3 of 12

    Tel: +86-571-56680806 www.ledtestlab.com

     

     

          

    TABLE OF CONTENT   

    LM-79-08 Test Report............................................................................................................................................ 1  

    Sample Photo.......................................................................................................................................................... 2  

    TEST RESULTS .................................................................................................................................................... 4  

    Spectral Power Distribution ................................................................................................................................... 5  

    IESNA Luminaire Flux Distribution Table ............................................................................................................ 6  

    Isoilluminance Plots of Horizontal Illuminance ..................................................................................................... 7  

    Luminous Intensity Distribution Plots.................................................................................................................... 8  

    Luminous Intensity Data ........................................................................................................................................ 9  

    EQUIPMENT LIST ............................................................................................................................................. 11  

    TEST METHODS ................................................................................................................................................ 11  

    Seasoning of SSL Product................................................................................................................................ 11  

    Goniophotometer Method ................................................................................................................................ 11  

    Photometric and Electrical Measurements ................................................................................................... 11  

    Color Characteristics Measurements............................................................................................................ 12  

    Color Spatial Uniformity ............................................................................................................................. 12

  • Report No.: HZ15110041a

    Prepared by: Leading Testing Laboratories No.1805, DongLiu road, BinJiang District, Hangzhou, China

    Page 4 of 12

    Tel: +86-571-56680806 www.ledtestlab.com

     

     

    Special Color Rendering Indices R1 82R2 89R3 93R4 83R5 83R6 85R7 87R8 68R9 10R10 74R11 82R12 63R13 84R14 97

      TEST RESULTS

     

    Test ambient temperature was 24.5 . Sample orientation was light down. Test was conducted without a dimmer in the circuit. The stabilization time of the sample was 60 minutes, and the total operating time including stabilization was 85 minutes.

     Goniophotometer Method The photometric distance is 30m. Luminous data was taken at 0.5°vertical intervals and 5 °horizontal intervals.

     

      Parameter

     Result

    Test Voltage (V) 120.0 277.0Voltage frequency (Hz) 60 60Test Current (A) 0.124 0.060Power Factor 0.9810 0.8989Test Power (W) 14.63 14.94THD A% 17.41 17.06Luminous Efficacy (lm/W) 96.6  Total Luminous Flux (lm) 1413.5Color Rendering Index (CRI) 83.7R9 10Correlated Color Temperature (CCT) (K) 5243Chromaticity (Chroma x, Chroma y) (0.3389, 0.3513)Chromaticity (Chroma u, Chroma v) (0.2074, 0.3224)Chromaticity (Chroma u’, Chroma v’) (0.2074, 0.4836)Duv 0.0024Average Beam Angle (°) 104.5Center Beam Candle Power (cd) 548Spacing Criteria 1.27 (0°-180°)/

    1.38 (90°-270°)Zonal Lumens in the 0°-60°Zone 88.12%Zonal Lumens in the 60°-90°Zone 11.73%Zonal Lumens in the 90°-120°Zone 0.03%Zonal Lumens in the 120°-180°Zone 0.12%

    Table 2: Test data per Goniophotometer Method Note: According to CIE 1976 (u’,v’) diagram, u’ = u = 4x/(-2x+12y+3), v’ = 3v/2 = 9y/(-2x+12y+3).

  • Report No.: HZ15110041a

    Prepared by: Leading Testing Laboratories No.1805, DongLiu road, BinJiang District, Hangzhou, China

    Page 5 of 12

    Tel: +86-571-56680806 www.ledtestlab.com

     

     

      Spectral Power Distribution   

                                Chart 1: Spectral Power Distribution

  • Report No.: HZ15110041a

    Prepared by: Leading Testing Laboratories No.1805, DongLiu road, BinJiang District, Hangzhou, China

    Page 6 of 12

    Tel: +86-571-56680806 www.ledtestlab.com

     

     

      IESNA Luminaire Flux Distribution Table

     

    Zone Lumens Luminaire % FL - Front-Low (0-30) 226.5 16.0 FM - Front-Medium (30-60) 399.2 28.2 FH - Front-High (60-80) 82.1 5.8 FVH - Front-Very High (80-90) 3.9 0.3 Total Forward Light 711.7 50.3

     BL - Back-Low (0-30) 228.4 16.2 BM - Back-Medium (30-60) 391.6 27.7 BH - Back-High (60-80) 76.9 5.4 BVH - Back-Very High (80-90) 3.0 0.2 Total Back Light 699.9 49.5

     UL - Uplight-Low (90-100) 0.1 0.0 UH - Uplight-High (100-180) 2.0 0.1 Total Up Light 2.1 0.1

     BUG (Back, Up, Glare) Rating B1-U1-G0

    Table 3: Flux Distribution Data   

     Zone

    Downward Lumens

    Upward Lumens

    Total Lumens

    House Side 699.9 0 699.9 Street Side 711.7 0 711.7

    Table 4: Flux Distribution Table   

    Note: The Flux in this table might be a little different from the total flux in Table 2 due to rounding.

  • Report No.: HZ15110041a

    Prepared by: Leading Testing Laboratories No.1805, DongLiu road, BinJiang District, Hangzhou, China

    Page 7 of 12

    Tel: +86-571-56680806 www.ledtestlab.com

     

     

     Isoilluminance Plots of Horizontal Illuminance

     

      

    Distance In Units Of Mounting Height Values Based On 10 Foot Mounting Height 1/2 Maximum Candela Trace Shown As Dashed Curve (+) = Maximum Candela Point

    Chart 2: Illuminance Plot (Footcandles)

  • Report No.: HZ15110041a

    Prepared by: Leading Testing Laboratories No.1805, DongLiu road, BinJiang District, Hangzhou, China

    Page 8 of 12

    Tel: +86-571-56680806 www.ledtestlab.com

     

     

      Luminous Intensity Distribution Plots

     

     

    Chart 3: Maximum Plane and Cone Plots of Candela Maximum Candela = 577.45 Located At Horizontal Angle = 190, Vertical Angle = 16.5 # 1 - Vertical Plane Through Horizontal Angles (190 - 10) (Through Max. Cd.) # 2 - Horizontal Cone Through Vertical Angle (16.5) (Through Max. Cd.)

      

     

    Chart 4: Polar Candela Distribution

  • Report No.: HZ15110041a

    Prepared by: Leading Testing Laboratories No.1805, DongLiu road, BinJiang District, Hangzhou, China

    Page 9 of 12

    Tel: +86-571-56680806 www.ledtestlab.com

     

     

      Luminous Intensity Data   

                                             Table 5: Luminous Intensity Data

  • Report No.: HZ15110041a

    Prepared by: Leading Testing Laboratories No.1805, DongLiu road, BinJiang District, Hangzhou, China

    Page 10 of 12

    Tel: +86-571-56680806 www.ledtestlab.com

     

     

     

    Table 6: Luminous Intensity Data

  • Report No.: HZ15110041a

    Prepared by: Leading Testing Laboratories No.1805, DongLiu road, BinJiang District, Hangzhou, China

    Page 11 of 12

    Tel: +86-571-56680806 www.ledtestlab.com

     

     

     EQUIPMENT LIST

     

     

    Test Equipment  

    Model Equipment No. Calibration Date

    Calibration Due date

    Goniophotometer system GO-R5000 HZTE011-01 Jul. 17, 2015 Jul. 16, 2016 Digital Power Meter PF2010A HZTE028-01 Jul. 17, 2015 Jul. 16, 2016 AC Power Supply PCR 500L HZTE001-08 Jul. 17, 2015 Jul. 16, 2016 DC Power Supply WY12010 HZTE004-03 Jul. 17, 2015 Jul. 16, 2016 Temperature Meter TES1310 HZTE017-01 Jul. 17, 2015 Jul. 16, 2016 Standard Source D908 HZTE012-01 Jul. 23, 2015 Jul. 22, 2016 Standard source SCL-1400 HZTE012-02 Oct. 21, 2015 Oct. 20, 2016

    Table 7: Test Equipment List  TEST METHODS

      

    Seasoning of SSL Product  

    For the purpose of rating new SSL products, SSL products shall be tested with no seasoning. Therefore, no seasoning was performed.

       Goniophotometer Method

      

    Photometric and Electrical Measurements   

    An EVERFINE Type C Model GO-R5000 Goniophotometer was used to measure the intensity at each angle of distribution for each sample. The photometric distance is 2.475m for near-field measurement or 30m for far-field measurement. Bandwidth of spectroradiometer is 380nm-780nm. Ambient temperature was measured at the same height of the sample mounted on the Goniophotometer equipment. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation. The stabilization time typically ranges from 30 min (small integrated LED lamps) to 2 or more hours for large SSL luminaires). It can be judged that stability is reached when the variation (maximum – minimum) of at least 3 readings of the light output and electrical power over a period of 30 min, taken 15 minutes apart, is less than 0.5 %. Electrical measurements including voltage, current, and power were measured using the Everfine Digital Power Meter. Some graphics were created with Photometric Plus software. The standard reference of the Goniophotometer system is halogen incandescent lamp, the intensity distribution type is omni-directional, and is traceable to the National Institute of Metrology P.R. China. The uncertainty of goniophotometer system reported in this document is expended uncertainty is 1.8% with a coverage factor k=2.

  • Report No.: HZ15110041a

    Prepared by: Leading Testing Laboratories No.1805, DongLiu road, BinJiang District, Hangzhou, China

    Page 12 of 12

    Tel: +86-571-56680806 www.ledtestlab.com

     

     

     Color Characteristics Measurements

      

    The color characteristics of SSL products include chromaticity coordinates, correlated color temperature, and color rendering index. These characteristics of SSL products may be spatially non-uniform, and thus, in order that they can be specified accurately, the color quantities shall be measured as values that are spatially average, weighted to intensity, over the angular range where light is intentionally emitted from the SSL product. The color characteristics measurements are using gonio-spectroradiometer.

       

    Color Spatial Uniformity   

    The characteristics of SSL products may be spatially non-uniform, the chromaticity coordinate shall be measured at two vertical planes (C=0°/180° and C=90°/270°) and at 10° or less intervals for vertical angle until the light output dropped to below 10% of the peak intensity. The average weighted chromaticity coordinate was calculated from these points. The data was then analyzed to check for delta color differences of the u', v' chromaticity coordinates. The spatial non-uniformity of chromaticity, u'v', is determined as the maximum deviation ( distance on the CIE (u', v') diagram) among all measured po in ts from the spatially a v e r a g e d chromaticity coordinate. The geometry for the chromaticity measurement using gonio-spectroradiometer is shown as following.

      

          

    *** End of Report *** This report is considered invalidated without the Special Seal for Inspection of the LTL. This report shall not be altered, increased

    or deleted. The results shown in this test report refer only to the sample(s) tested. Without written approval of LTL, this test report

    shall not be copied except in full and published as advertisement.