A rmstrong Design Envelope pumps were selected to retrofit this 80,000 m2 office
and hotel complex. Because the hvac system is required 24/7 to support hotel operations, ease of installation and minimal labour were important considerations. Armstrong upgraded the existing equipment with 10 Design Envelope 4300 pumps and an ipc 9521 controller.
case study | Wei Lai Mansion
annual energy cost co2 emissions
before beforeafter after
average averageaverage
rmb rmb
average
283,647298,030 104,626 71,195
before before before
70,500
70,500
£31,000
45,005
45,005
£22,000
average averageaverage
after afterafter
average averageaverage
annual kwh usage annual energy cost co2 emissions
armstrongfluidtechnology.com /energyperformanceseries
name St James Hospital
facility type Healthcare
location Leeds, Yorkshire UK
before before before
70,500
70,500
£31,000
45,005
45,005
£22,000
average averageaverage
after afterafter
average averageaverage
annual kwh usage annual energy cost co2 emissions
armstrongfluidtechnology.com /energyperformanceseries
name St James Hospital
facility type Healthcare
location Leeds, Yorkshire UK
facility type Hotel and office complex
size 80,000 m2
location Zhengzhou,China
site challenges• Low tolerance for noise
and vibration• 24/7 hotel operations
demanded fast installation and commissioning for minimal system downtime
Armstrong solutions reduced energy usage by 75%. These energy savings reduced the payback period for the retrofit project to less than two years.
kg co2 kg co2
Energy Upgrade Series
Case study: Wei Lai Mansion
75%annual energy savings
a r m s t r o n g f lu i d t ec h n o lo g y. co m
rmb
t o g e t yo u r e n e rgy u p g r a d e proj ec t s ta r t e d, c a ll :
annual cost savings annual c02 emission reduction
193,404 212,452 kg CO2
+1 866 238 1337
bureau veritas
verified
Site 80,000 m2 office and hotel specification constructed in 1997
Equipment 10 × Design Envelope Vertical included In-Line 4300 pump with Suction Guide and Flo-Trex valve
key outcomes:
Bureau Veritas reviewed the energy usage data and certified the efficiency improvement of 75%
The cost savings will be rmb 193,404 per year (approx $28,000 usd)
file no.: 9.566 date: october 2019 supersedes: 9.566 date: august 2019
Bureau Veritas S. A. is an international certification
agency appointed by Armstrong to provide a
technical assessment of pump performanceand energy usage.
A rmstrong maps each individual pump’s hydraulic, motor and inverter variations at the factory to achieve exceptional accuracy
throughout the flow range. With this calibration, Armstrong Design Envelope pumps also serve as
flow meters, providing reliable system flow data (+/- 5%). The testing ensures optimal performance efficiency at start-up, while Armstrong’s Pump Manager helps maintain and extend efficiency throughout the pump’s operating life.
vertical in-line pump
ipc 9511
solutions employed