2
Consultant BSD Client Lord Combustion Limited Sector Education Products DW Flue System Equipment MHS ADI LT Application High Efficiency Condensing 0844 809 2509 | airtherm.co.uk | [email protected] Project Profile Oakham Primary School, Dudley, West Midlands Front Entrance Twin wall flue Airtherm have recently designed, supplied and installed a complete twin wall stainless steel flue system serving each MHS Adinox ADI LT 200 modulating boiler at Oakham Primary School in Dudley in the West Midlands. The existing cast iron boilers were removed by the contractor during the School summer shut-down, working on a tight program the MHS high efficiency boilers were installed followed by the installation of our flue system. All of the plant was commissioned in time for the return of the pupils to enter a new begging. The flue system installed was designed to completely evacuate the products combustion taking into account for the over-pressure from each appliance. Each primary flue incorporated a volume control damper and draft regulator in the event of unstable operation. The complete system had a 3 0 fall back to the appliance to allow condense to vacate and drain from the flue. Airtherm Engineering Ltd only uses branded products which are synonymous with the highest quality - and it is this reputation that enables specifiers and contractors to use our versatile product range with total confidence We can provide technical solutions for the specialist areas of high temperature exhaust systems, serving generators & combined heat and powder units, fan assisted, flue dilution and atmospheric applications. MHS ADI LT Boilers Header System with 3 0 incline

Case study for oakham primary school

Embed Size (px)

DESCRIPTION

Airtherm have recently designed, supplied and installed a complete twin wall stainless steel flue system serving each MHS Adinox ADI LT 200 modulating boiler at Oakham Primary School in Dudley in the West Midlands. This installation of a 10m, 3nr MHS Adinox ADI LT 200 flue for a gas condensing boiler system comprised of a twin wall insulated stainless steel pre-fabricated exhaust system, manufactured from a 0.6mm grade 316L inner liner and a 0.4mm grade 304L outer case with the 37.5mm void packed of 128kg/m3 high density insulation. The system used gives a positive pressure resistance of up to 2KPa and a continuous high temperature capability of up to 760°C independently tested to BS 476: Part 24 for 4 hours. All of the products used are approved and CE marked to EN 1856-1 and manufactured under a quality assurance scheme, administered by British Standards in accordance with BS EN 9001: 2008.

Citation preview

Page 1: Case study for oakham primary school

Consultant

■ BSD

Client

■ Lord Combustion Limited

Sector

■ Education

Products

■ DW Flue System

Equipment

■ MHS ADI LT

Application

■ High Efficiency Condensing

0844 809 2509 | airtherm.co.uk | [email protected]

Project Profile

Oakham Primary School, Dudley, West Midlands

Front Entrance

Twin wall flue

Airtherm have recently designed, supplied and installed a complete twin wall stainless steel flue system serving each MHS Adinox ADI LT 200 modulating boiler at Oakham Primary School in Dudley in the West Midlands. The existing cast iron boilers were removed by the contractor during the School summer shut-down, working on a tight program the MHS high efficiency boilers were installed followed by the installation of our flue system. All of the plant was commissioned in time for the return of the pupils to enter a new begging. The flue system installed was designed to completely evacuate the products combustion taking into account for the over-pressure from each appliance. Each primary flue incorporated a volume control damper and draft regulator in the event of unstable operation. The complete system had a 30 fall back to the appliance to allow condense to vacate and drain from the flue. Airtherm Engineering Ltd only uses branded products which are synonymous with the highest quality - and it is this reputation that enables specifiers and contractors to use our versatile product range with total confidence We can provide technical solutions for the specialist areas of high temperature exhaust systems, serving generators & combined heat and powder units, fan assisted, flue dilution and atmospheric applications. MHS ADI LT Boilers

Header System with 30 incline

Page 2: Case study for oakham primary school

• Boilers: MHS

• Model: ADI LT 200

• Application: Chimney / Flue system

• Operating mode: Wet

• Pressure: Negative / positive pressure

• Working pressure: 200 Pa (product will operate 1000pa max)

• Inner wall: 316L1.4404/1.457 thickness 0,6 mm

• Outer wall: 304/ 1.4301 thickness 0,5

• Insulation: 30mm thick Rockwool insulation

• Sealant : Tri-lip 'o' type silicone ring

• Fuel type: Gas

• Other Application Dinak Flues can be used:

• Condensing boilers

• Atmospheric gas-fired boilers

• Gas blown boilers

• Industrial ovens, large-scale establishments

• Wood-fired stoves

0844 809 2509 | airtherm.co.uk | [email protected]

Product Solution

Airtherm Masterflue

Contact Details:

Airtherm Engineering Ltd

Ventilation House

Pedmore

Stoubridge

West Midlands

DY9 0DS

Tel: 0844 8092509

Fax: 01562 887312

Primary Flues