Loadlog 800/8000 InstallationSupplement
This supplement will show some of the locations for mounting the equipment included in this scale system.The installations shown are not required locations they are only intended as a guide.
Case 721E XT
Head Unit Mounting
The Head Unit is mounted to a brace that extends between the two mounting studs on the ROPS.This location provides easy access by the operator. Never drill into a ROPS.
Loadlog 800/8000 InstallationSupplement
This installation is done by removing the T-fitting and using the drill and tap providedin the kit to create a port for the load sensors. One in the pressure and one in the Return.
Case 721E XT
Load Sensor Mounting
The sensor mount is to the plate close to the tee fittings using the brackets suppliedby drilling a hole or using an existing stud or bracket.
Load Sensor Installation
Loadlog 800/8000 InstallationSupplement
The Ref/Dir sensor is mounted to the bracket on the XL Series. The 721E Series wouldhave used the long bracket and been mounted in the same location.
Case 721E XT
Reference/Direction Sensor
The magnet is mounted to the arm with the existing bolt. On the 721E there is a clampbracket available from Loup Electronics that clamps over the lift arm and holds the magnet.
Normal weighing height is bottom of bucket about 6 feet off the ground.
Reference/Direction Sensor
Loadlog 800/8000 InstallationSupplement
Case 721E XT
Remote Enter SwitchThe remote enter switch needs to be mounted to allow easy access by the operator..
The Cable end is routed under the console and back to the junction box.
Juncton Box Mounting
The junction box is loacated behind the right side access panel and the sensor cables arerouted through the gromet with the hoses.
Loadlog 800/8000 InstallationSupplement
Case 721E XT
Wiring and ConnectionsThe cables were routed in beside the hoses to the junction box.
Use the black loom to cover the cables to help prevent premature failure. Use caution when routing cablesthrough the center piviot of the machine.
Wiring and Connections
The head unit cable is routed down the post and under the right hand console back to the junction box.If a printer is being installed this cable would be routed at the same time in the split loom.
Loadlog 800/8000 InstallationSupplement
Case 721E XT
Wiring and ConnectionsPower connections will be found behind the right hand access panel where the junction
box will be located. Find a keyed 12 or 24 volt supply. The printer power is made here as well.